DESIGN TEAM Martin/Martin ME Engineers Studio Insite Design Balance Ambient Energy WELCOME CENTER COLORADO SCHOOL OF MINES GOLDEN, CO MAY 2, 2014 100% CD SET

Upload: others

Post on 28-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C1.00 COVER SHEET CURRENT/CSM WELCOME CENTER/01 Genera… · 100% cd set. 1 a101 sim a101 1 sim building section reference interior section detail reference centerline room identification

DESIGN TEAM

Martin/MartinME EngineersStudio Insite

Design BalanceAmbient Energy

WELCOME CENTERCOLORADO SCHOOL OF MINES GOLDEN, CO

MAY 2, 2014

100% CD SET

Page 2: C1.00 COVER SHEET CURRENT/CSM WELCOME CENTER/01 Genera… · 100% cd set. 1 a101 sim a101 1 sim building section reference interior section detail reference centerline room identification

1

A101

SIM

A101

1SIM

BUILDING SECTIONREFERENCE

INTERIOR SECTIONDETAIL REFERENCE

CENTERLINE

ROOM IDENTIFICATION

3

24

1

A5.60

NORTH ARROW

W WINDOW NUMBER

11.44A

Room name101

150 SF

DOOR NUMBER

WRGB24' - 0"

100'-0"

EVENT LEVEL

100'-0"

ROOM NAMEROOM NUMBERROOM AREA

CEILING TAG

CEILING MATERIALCEILING HEIGHT

ELEVATION TAGS

SPOT ELEVATIONS

(FLOOR NAME)

(FLOOR ELEVATION)

##-#- -R1 1 A1

2

1

A4.30

SIM

WALL TYPERE: LEGEND ONSHEET A9.00

ENLARGED PLAN / DETAIL

DRAWING NUMBER

FLOOR ELEVATION

0GRID BUBBLES

GRID NUMBER

INTERIOR ELEVATIONSHEET NUMBER

DRAWING NUMBER

1

A101

SIM WALL SECTIONREFERENCE

9' - 4"

DIMENSIONALL PLAN DIMENSIONS ARE TO FACE OF STUDFRAMING OR FACE OF MASONRY UNLESSNOTED OTHERWISE

TS-01TOILET ACCESSORIES TAGSEE LEGEND ONSHEET A5.00

TG-W4 TOILET / SHOWER GROUPSEE LEGEND ONSHEET A5.00

EQ-69 EQUIPMENT TAGSEE SCHEDULE ONSHEET A0.10

? KEYNOTE

WALL TYPE EXTERIOR ASSEMBLY TAG

BRICK

CONCRETE BLOCK

CAST IN PLACECONCRETE

PRECAST CONCRETE

CAST STONE

CUT STONE

COMPACTED FILL

UNDISTURBED EARTH

GRAVEL

BATT INSULATION / SOUNDATTENUATION BLANKETS

RIGID INSULATION

WOOD BLOCKING

FINISH WOOD - CUT

STEEL

PLYWOOD/SHEATHING

ALUMINUM (LARGESCALE)

GYPSUM BOARD

ACOUSTICAL WALL PANEL

SAFP (SPRAY APPLIEDFIRE PROOFING)

PROJECT SITE

18TH ST.

19TH ST. ILLINOIS ST.

ELM ST.

17TH ST.

MAPLE ST.

US-6

ABBREVIATIONS

COLORADO SCHOOL OF MINES - WELCOME CENTERGOLDEN, COLORADO

LEGEND VICINITY MAPMATERIAL SYMBOLS

GENERAL NOTES

UNO UNLESS NOTED OTHERWISE

V

VACT VINYL COATED ACT

VB VAPOR BARRIER

VCT VINYL COMPOSITION TILE

VEN VENEER

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

W

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WND WINDOW

WP WORKING POINT

WR WATER RESISTANT

WRGB WATER RESISTANT GYPSUM BOARD

WT WEIGHT

WWF WELDED WIRE FABRIC

X

XS EXPOSED STRUCTURE

OFF OFFICE

OFOI OWNER FURNISHED, OWNERINSTALLED

OH OPPOSITE HAND

OPG OPENING

OPP OPPOSITE

OTO OUTSIDE-TO-OUTSIDE

OVHD OVERHEAD

P

PB PARTICAL BOARD

PC PRECAST CONCRETE

PER PERIMETER

PL PLATE

PLAM PLASTIC LAMINATE

PMW PREFINISHED METAL WALL PANEL

PNL PANEL(BOARD)

PNTD PAINTED

PR PAIR

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSL PARALLEL STRAND LUMBER

PT PAINT

PTD PAPER TOWEL DISPENSER

PV PAVEMENT

PWR POWER

Q

Q QUADRANT

QT QUARRIED TILE

QTY QUANTITY

QUAD QUADRANT

R

R RADIUS / RISER

RA RETURN AIR

RB RUBBER BASE

RBF RUBBER FLOORING

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RE REFER TO or REFERENCE

REC RECEPTACLE

REF REFERENCE

REINF REINFORCING

REQ REQUIRED

RESIL RESILIENT

REV REVISE, REVISED or REVISION

RM ROOM

RO ROUGH OPENING

ROD ROOF OVERFLOW DRAIN

ROW RIGHT OF WAY

RT RESILIENT TILE

RTG RATING

S

S SOUTH

SAN SANITARY

SC SOLID CORE

SCHD SCHEDULE

SECT SECTION

SF SQUARE FEET

SHT SHEET

SHTG SHEATHING

SHWR SHOWER

SIM SIMILAR

SPEC SPECIFICATION(S)

SQ SQUARE

SS STAINLESS STEEL

SS SOLID SURFACE

ST STAINED

STBD STRAW BOARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURE or STRUCTURAL

SVB SHEET VINYL BASE

SVF SHEET VINYL FLOORING

SYM SYMMETRICAL

SYS SYSTEM

T

T TILE

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TEL TELEPHONE

TEMP TEMPORARY

THK THICK or THICKNESS

TMPRD TEMPERED

TO TOP OF

TRANS TRANSFER

TV TELEVISION

TYP TYPICAL

U

UL UNDERWRITER'S LABORATORY

FHC FIRE HOSE CABINET

FIN FINISH(ED)

FL FLOOR(ING)

FLEX FLEXIBLE

FLUOR FLUORESCENT

FO FACE OF

FRP FIBER RESIN PANEL

FRTW FIRE RESISTANT TREATED WOOD

FS FLOOR SINK

FT FOOT/FEET

FTG FOOTING

FUT FUTURE

FV FIELD VERIFY

G

GA GAUGE

GALV GLAVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GL GLASS/ GLAZING

GRD GRID LINE

GYP GYPSUM BOARD

H

HB HOSE BIB

HDWD HARDWOOD

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HSS HOLLOW STRUCTURAL SECTION

HT HEIGHT

HTG HEATING

HVAC HEATING, VENTILATION and AIRCONDITIONING

I

IBC INTERNATIONAL BUILDING CODE orINSTALLED BY CONTRACTOR

ID INSIDE DIAMETER

IN INCH

INFO INFORMATION

INSUL INSULATION or INSULATED

INT INTERIOR

IRGB INPACT RESISTANT GYPSUM BOARD

J

JAN JANITOR

JB JUNCTION BOX

JT JOINT

K

KD KNOCKDOWN

KO KNOCKOUT

L

L LENGTH

LAM LAMINATE

LAV LAVATORY

LH LEFT HAND

LKR LOCKER

LL LIVE LOAD

LP LIGHTING PANEL

LT LIGHT

LTG LIGHTING

M

M MIRROR

MAS MASONRY

MAT MATERIAL

MAX MAXIMUM

MDF MEDIUM DENSITY FIBERBOARD

MECH MECHANICAL

MEP MECHANICAL, ELECTRICAL andPLUMBING

MFR MANUFACTURER

MID MID-POINT/MIDDLE

MIN MINIMUM

MISC MISCELLANEOUS

ML METAL LOCKERS

MO MASONRY OPENING

MT MOUNT(ED)

MTD MOUNTED

MTL METAL

N

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED, CONTRACTORINSTALLED

_

# POUND(S) or NUMBER

& AND

< ANGLE

@ AT

A

AB ANCHOR BOLT

ACM ALUMINUM COMPOSITE PANEL

ACT ACCOUSTICAL CEILING TILE

AD AREA DRAIN

ADA ACCESSIBLE

AF ATHLETIC FLOORING

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE(LY)

ARCH ARCHITECTURAL

ASI ARCHITECT'S SUPPLEMENTALINSTRUCTIONS

AUTO AUTOMATIC

B

BB BACKER BOARD

BD BOARD

BLDG BUILDING

BO BOTTOM OF

BP BUILDING PAPER

C

CATV CABLE TELEVISION

CB CARPET BASE

CBB CEMENTITIOUS BACKER BOARD

CCTV CLOSED CIRCUIT TELEVISION

CFCI CONTRACTOR FURNISH,CONTRACTOR INSTALL

CFMF COLD FORMED METAL FRAMING

CFOI CONTRACTOR FURNISH, OWNERINSTALL

CFT CERAMIC FLOOR TILE

CG CORNER GUARD

CIP CAST IN PLACE

CJ CONTROL JOINT

CL CENTERLINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CNTR COUNTER

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACT(OR)

CORR CORRIDOR

CPT CARPET

CT CERAMIC TILE

CTB CERAMIC TILE BASE

D

DBL DOUBLE

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISCONT DISCONTINUOUS

DN DOWN

DS DOWNSPOUT

DTL DETAIL

DWG DRAWING

E

EA EACH

EJ EXPANSION JOINT

ELEC ELECTRICAL

ELEV ELEVATOR

EP EPOXY PAINT

EQ EQUAL/EQUIVALENT

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EX EXPOSED

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

F

FAA FIRE ALARM ANNUNCIATOR

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FFE FINISHED FLOOR ELEVATION

FG FINISH GRADE

FH FIRE HYDRANT

All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs

Issues/Revisions: Date:

SCD Project No.:

10/16/13SCHEMATIC DESIGN

02/07/14DESIGN DEVELOPMENT

04/04/1480% CD SET / PERMIT SET

05/02/14100% CD SET

WELCOME CENTER

A0.01

LEGENDS &ABBREVIATIONS

COLORADO SCHOOL OF MINESGOLDEN, CO

1219

PROJECT TEAM

OWNER

COLORADO SCHOOL OF MINESCAPITAL PLANNING ANDCONSTRUCTION1318 MAPLE STREETGOLDEN, CO 80401PHONE: 303-384-2517CONTACT: SUSAN MINER

ARCHITECT

SINK COMBS DETHLEFS475 LINCOLN STREET, SUITE 100DENVER, CO 80203PHONE: 303-308-0200CONTACT: KEVIN ARMSTRONG

CIVIL ENGINEER

MARTIN / MARTIN12499 W. COLFAX AVENUELAKEWOOD, CO 80215PHONE: 303-431-6100CONTACT: SCOTT PALING

LANDSCAPE ARCHITECT

studioINSITE3457 RINGSBY COURT, UNIT 223DENVER, CO 80216PHONE: 303-433-7100CONTACT: CHRIS GEDDES

STRUCTURAL ENGINEER

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

SPECIFICATIONS

MARTIN / MARTIN12499 W. COLFAX AVENUELAKEWOOD, CO 80215PHONE: 303-431-6100CONTACT: JOHN BRUNNER

ME ENGINEERS10055 W. 43RD AVENUEWHEAT RIDGE, CO 80033PHONE: 303-421-6655CONTACT: LEONARD GURULE

JAMES MILLER1137 SHERMAN STREET #17DENVER, CO 80203(303) 475-0348

ME ENGINEERS10055 W. 43RD AVENUEWHEAT RIDGE, CO 80033PHONE: 303-421-6655CONTACT: ED HORNFECK

LEED CONSULTANT

DESIGN BALANCEP.O. BOX 7214MISSOULA, MT 59807(406) 721-7077CONTACT: KELLY KARMEL

ENERGY MODELING CONSULTANT

AMBIENT ENERGY130 W. 5TH AVENUEDENVER, CO 80203(303) 278-1532CONTACT: LINDA MORRISON

NORTH

NOT TO SCALE

I) EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 SQUARE FEET, AND;II) EXPOSED BOTTOM EDGE IS LESS THAN 18 INCHES ABOVE THE FLOOR, AND;III) EXPOSED TOP EDGE IS GREATER THAN 36 INCHES ABOVE THE FLOOR, AND;IV) ONE OR MORE WALKING SURFACES ARE WITHIN 36" HORIZONTALLY OF THE PLANEOF THE GLAZING.

A) FIXED AND SLIDING PANELS IN SWINGING DOORS.B) WINDOWS WITHIN 24" OF DOORS IN ANY POSITION NOT MORE THAN 60" ABOVEWALKING SURFACE.C) INDIVIDUAL FIXED OR OPERABLE PANELS, OTHER THAN THOSE LOCATIONSDESCRIBED ABOVE, THAT MEET ALL OF THE FOLLOWING CONDITIONS:

REFER TO CODE ANALYSIS REPORT FOR A LISTING OF APPLICABLE BUILDING CODES AND STANDARDS. ITSHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND RESPECTIVE SUBCONTRACTORS TOBUILD TO SATISFY THESE CODES AND CALL FOR ALL NECESSARY INSPECTIONS.

REFER TO PROJECT SPECIFICATIONS FOR FURTHER DEFINITION OF THE WORK.

THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE AND REPORT ALL DISCREPANCIESTO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. CONTACT ARCHITECT FOR CLARIFICATION INTHE EVENT OF ANY DISCREPANCY IN THE CONSTRUCTION DOCUMENTS OR ANY AMBIGUITY OFARCHITECTURAL INTENT.

ALL LEGAL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIALKNOWLEDGE OR EFFORT.

ALL PLAN DIMENSIONS ARE TO CENTERLINE OF COLUMN GRID, FACE OF STUD FRAMING FACE OF CONCRETEOR FACE OF CMU UNLESS NOTED OTHERWISE.

THE LARGEST SCALE DRAWING SHALL GOVERN OVER ALL OTHER DRAWINGS.

"F.V." (FIELD VERIFICATION) OR "V.I.F."(VERFIY IN FIELD) ON DRAWINGS REFERS TO CONTRACTOR CHECKING ASPECIFIC AREA FOR CORRECT DIMENSIONS AND CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES.

DO NOT SCALE DRAWINGS

THE GENERAL CONTRACTOR SHALL PREP ALL FLOORS TO RECEIVE FINISHES.

PROVIDE BACKING PLATES IN WALL FOR ALL WALL MOUNTED EQUIPMENT AND CASEWORK AS INDICATED INTHE DRAWINGS.

COORDINATE DUCT, FLUE, AND VENT PENETRATIONS WITH MECHANICAL CONTRACTOR.

LOCATE ALL PLUMBING IN PROTECTED AREAS OR PROVIDE MEANS TO AVOID FREEZING OF PIPES AND TRAPS.

ALL ELEVATIONS SHOWN ON PLANS ARE BUILDING ELEVATIONS (MAIN LEVEL = 100'-0")

PAINT ALL INTERIOR CONDUIT, DUCTWORK, PIPING, ETC., IN FINISHED SPACES EXPOSED TO PUBLIC VIEW.

PAINT ALL EXPOSED METAL ON EXTERIOR OF BUILDING WITH HIGH PERFORMANCE PAINT SYSTEM THAT ISNOT INDICATED TO BE PREFINISHED U.N.O., INCLUDING BUT NOT LIMITED TO CONDUIT, PIPING, GAS PIPING,FLASHING, MECH. FLUES AND DUCTS, LINTELS, HOLLOW METAL FRAMING AND DOORS, STEEL, AND MECH.EQUIPMENT.

PROVIDE TRAPEZE TO SUPPORT SUSPENDED CEILINGS AS REQUIRED BELOW DUCTWORK OR OTHEROBSTRUCTIONS.

COORDINATE ALL WOOD BLOCKING AND SHEATHING WITH REQUIREMENTS OF THE IBC.

WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS LISTED IN THE IBC.

PROVIDE ACCESS PANELS AT LOCATIONS INDICATED AND AS REQUIRED FOR ACCESS TO EQUIPMENT ANDDEVICES INCLUDING, BUT NOT LIMITED TO MECHANICAL, PLUMBING, AND ELECTRICAL WORK.

PROVIDE AN ALLOWANCE FOR 50 CORNER GUARDS TO BE PLACED AT GYP. BD. WALL CORNER LOCATIONS.

PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR-CEILINGS AND ROOF-CEILINGS SHALL BE PROTECTED ASREQUIRED IN THE IBC.

GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE OF SAFETY GLAZING PER SECTION 2406.3 OF THE IBC.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23. PROVIDE FIRE EXTINGUISHERS AS INDICATED THUS ON THE DRAWINGS.

FE: INDICATES A FIRE EXTINGUISHER INSTALLED ON A WALL-MOUNTED BRACKET.

SHEET INDEX

A1.00 EXISTING SITE / DEMO PLAN & ARCHITECTURAL SITE PLAN

A2.10 BASEMENT & FIRST LEVEL FLOOR PLANS

A2.20 SECOND & THIRD LEVEL FLOOR PLANS

A2.30 ROOF LEVEL PLAN

A3.10 BUILDING ELEVATIONS

A3.11 BUILDING ELEVATIONS

A3.20 BUILDING SECTIONS

A3.21 BUILDING SECTIONS

A3.30 WALL SECTIONS

A3.31 WALL SECTIONS

A3.40 AERIAL ISOMETRICS

A4.10 ENLARGED PLANS & ELEVATIONS

A4.11 ENLARGED PLANS & ELEVATIONS

A4.12 ENLARGED PLANS & ELEVATIONS

A4.20 ENLARGED PLANS & ELEVATIONS

A4.30 ENLARGED PLANS & ELEVATIONS

A5.50 STANDARD MILLWORK DETAILS

A5.51 MILLWORK & RCP DETAILS

A6.10 BASEMENT & FIRST LEVEL REFELCTED CEILING PLANS

A6.20 SECOND & THIRD LEVEL REFELCTED CEILING PLANS

A7.10 STAIR & ELEVATOR PLANS & SECTIONS

A7.20 STAIR & LADDER DETAILS

A8.10 SITE, PLAN, & EXTERIOR WALL DETAILS

A8.20 EXTERIOR WALL DETAILS

A8.30 ROOF DETAILS

A9.00 WALL TYPES AND FRAMING NOTES

A9.01 PARTITION FRAMING CRITERIA

A9.02 CEILING DETAILS

A9.60 SIGNAGE SCHEDULE & DETAILS

A9.61 BASEMENT & FIRST LEVEL SIGNAGE PLANS

A9.62 SECOND & THIRD LEVEL SIGNAGE PLANS

A9.70 ROOM FINISH SCHEDULE & LEGEND

A9.71 BASEMENT & FIRST FLOOR FINISH PLANS

A9.72 SECOND & THIRD FLOOR FINISH PLANS

A9.80 DOOR SCHEDULE

A9.81 WINDOW ELEVATIONS

A9.82 WINDOW ELEVATIONS

A9.83 WINDOW & DOOR DETAILS

A9.84 WINDOW & DOOR DETAILS

A9.85 WINDOW & DOOR DETAILS

A9.86 WINDOW & DOOR DETAILS

A0.01 LEGENDS & ABBREVIATIONS

A0.10 CODE ANALYSIS

A0.11 CODE ANALYSIS PLANS

A0.12 CODE ANALYSIS PLANS

TITLE SHEET

CIVILC1.00 COVER SHEETC1.01 EXISTING CONDITIONS & DEMOLITION PLANC2.00 HORIZONTAL CONTROL PLANC3.00 EROSION CONTROL PLANC3.01 EROSION CONTROL DETAILSC4.00 GRADING PLANC5.00 STORM SEWER PLAN AND PROFILEC6.00 TUNNEL PLANC7.00 OVERALL UTILITY PLANC8.00 DETAIL SHEETC8.01 DETAIL SHEETC8.02 DETAIL SHEETC8.03 DETAIL SHEETC8.04 DETAIL SHEET

LANDSCAPELS1.00 OVERALL LANDSCAPE SITE PLANLS1.01 LANDSCAPE SITE PLANLS1.02 LANDSCAPE SITE PLANLS2.01 LANDSCAPE SITE LAYOUT ENLARGEMENTSLS4.01 LANDSCAPE DETAILSLS4.02 LANDSCAPE DETAILSLS4.03 LANDSCAPE DETAILSLP1.00 OVERALL LANDSCAPE PLANTING PLANLP1.01 LANDSCAPE PLANTING PLANLP1.02 LANDSCAPE PLANTING PLANLP4.01 PLANTING DETAILSIR1.00 OVERALL IRRIGATION SITE PLANIR1.01 IRRIGATION DETAILSIR1.02 IRRIGATION DETAILS

ARCHITECTURAL

STRUCTURALS0.01 NOTESS0.02 NOTESS2.10 BASEMENT & FIRST FLOOR LEVEL PLANSS2.20 SECOND FLOOR LEVEL & LOBBY ROOF PLANSS2.30 THIRD FLOOR LEVEL & ROOF LEVEL PLANSS2.40 ROOF SCREEN PLANS3.00 TYP CONCRETE DETAILSS3.10 TYP DRILLED PIER DETAILSS3.11 SITE WALL DETAILSS3.12 FOUNDATION WALL DETAILSS3.13 FOUNDATION DETAILSS3.15 TYP STEEL TO CONCRETE CONNECTIONSS3.16 TYP SLAB DETAILSS3.17 UTILITY TUNNEL DETAILSS3.20 CONCRETE WALL ELEVATIONSS3.21 CONCRETE WALL ELEVATIONSS3.22 WALL SECTIONSS5.00 TYP STEEL BEAM CONNSS5.01 TYP STEEL BEAM CONNSS5.02 TYP STEEL DETAILSS5.03 STEEL GIRT CONNSS5.30 TYP METAL DECK DETAILSS5.31 TYP METAL DECK DETAILSS5.40 TYP WALL DETAILSS5.41 WALL DETAILSS5.42 WALL DETAILSS5.43 WALL DETAILS

MECHANICAL / PLUMBINGM0.00 MECHANICAL LEGENDM0.01 MECHANICAL NOTESM2.10 BASEMENT & FIRST FLOOR MECHANICAL PLANSM2.20 SECOND & THIRD FLOOR MECHANICAL PLANSM2.30 ROOF LEVEL MECHANICAL PLANM3.10 BASEMENT & FIRST FLOOR PIPING PLANSM3.20 SECOND & THIRD FLOOR PIPING PLANSM3.30 ROOF LEVEL PIPING PLANM4.10 ENLARGED MECHANICAL PLANSM6.00 MECHANICAL SCHEMATICS AND CONTROL DIAGRAMSM6.01 MECHANICAL SCHEMATICS AND CONTROL DIAGRAMSM6.02 MECHANICAL SCHEMATICS AND CONTROL DIAGRAMSM8.01 MECHANICAL DETAILSM8.02 MECHANICAL DETAILSM8.03 MECHANICAL DETAILSMEP0.01 MECHANICAL SCHEDULESMEP0.02 MECHANICAL SCHEDULES

MP2.00 TUNNEL PIPING PLANMP3.00 TUNNEL ENLARGED PLANSMP3.01 TUNNEL ENLARGED PLANSP0.00 PLUMBING LEGEND AND NOTESP0.01 PLUMBING SCHEDULESP1.00 PLUMBING AND MECHANICAL SITE PLANP2.00 UNDERGROUND PLUMBING PLANP2.10 BASEMENT & FIRST FLOOR PLUMBING PLANSP2.20 SECOND & THIRD FLOOR PLUMBING PLANSP2.30 ROOF FLOOR PLUMBING PLANP2.40 PLUMBING ENLARGED PLANSP3.00 PLUMBING RISER DIAGRAMSP3.01 PLUMBING RISER DIAGRAMSP4.00 PLUMBING DETAILS

FP2.10 FIRE PROTECTION

ELECTRICALE0.01 ELECTRICAL LEGENDE0.02 ELECTRICAL ONE-LINEE0.03 LIGHTING FIXTURE SCHEDULEE0.04 ELECTRICAL PANEL SCHEDULESE0.05 ELECTRICAL PANEL SCHEDULESE0.06 ELECTRICAL PANEL SCHEDULESE1.00 SITE ELECTRICAL PLANE2.10 BASEMENT & FIRST LEVEL ELECTRICAL PLANSE2.20 SECOND & THIRD LEVEL ELECTRICAL PLANSE2.30 ROOF LEVEL ELECTRICAL PLANE3.00 SITE LIGHTING PLANE3.10 BASEMENT & FIRST LEVEL LIGHTING PLANSE3.20 SECOND & THIRD LEVEL LIGHTING PLANSE3.30 ROOF LEVEL LIGHTING PLANE4.10 BASEMENT & FIRST LEVEL FIRE ALARM PLANSE4.20 SECOND & THIRD LEVEL FIRE ALARM PLANSE4.30 ROOF LEVEL FIRE ALARM PLANE5.01 ELECTRICAL DETAILS

TECHNOLOGYT0.01 TECHNOLOGY LEGENDT0.02 TECHNOLOGY ONE-LINEST1.00 TECHNOLOGY SITE PLANT1.01 TECHNOLOGY CAMPUS PLANT2.10 BASEMENT & FIRST LEVEL FLOOR PLANT2.20 SECOND & THIRD LEVEL FLOOR PLANT2.30 ROOF LEVEL FLOOR PLANT3.01 TECHNOLOGY TYPICAL ENLARGED ROOM PLANT4.01 TECHNOLOGY DETAILST4.02 TECHNOLOGY DETAILS

ADD ALTERNATES SCHEDULEALTERNATE 1: PROVIDE WOOD PANELING AS SHOWN IN DRAWINGS

LOCATED IN LOBBY 100, LOBBY 107, HERITAGE LOUNGE 108 & HALL C110ALTERNATE 2: CONCRETE SEAT WALL AT NORTH PLAZA IDENTIFIED ON LS1.01ALTERNATE 3: PROVIDE TRASH ENCLOSURE SHOWN ON A1.00ALTERNATE 4: PROVIDE CEILING UPGRADES IN LOBBY AREAS AS SHOWN IN RCPSALTERNATE 5: PROVIDE SOLID SURFACE COUNTER TOPS AT ALL LOCATIONS

BASE SCOPE PROVIDE PLAM AT COUNTERS AS INDICATED IN DRAWINGSALTERNATE 6: PROVIDE MINGLE TABLES & CHAIRS IDENTIFIED IN LANDSCAPE DRAWINGS

REFER TO SPECIFICAITON 012300 FOR FURTHER DEFINITION OF ALTERNATES / BASE SCOPE

NORTH

Page 3: C1.00 COVER SHEET CURRENT/CSM WELCOME CENTER/01 Genera… · 100% cd set. 1 a101 sim a101 1 sim building section reference interior section detail reference centerline room identification

All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs

Issues/Revisions: Date:

SCD Project No.:

10/16/13SCHEMATIC DESIGN

02/07/14DESIGN DEVELOPMENT

04/04/1480% CD SET / PERMIT SET

05/02/14100% CD SET

WELCOME CENTER

A0.10

CODE ANALYSIS

COLORADO SCHOOL OF MINESGOLDEN, CO

1219

Page 4: C1.00 COVER SHEET CURRENT/CSM WELCOME CENTER/01 Genera… · 100% cd set. 1 a101 sim a101 1 sim building section reference interior section detail reference centerline room identification

420 SF

MAINMECHANICAL

2880 SFSTORAGE 195 SF

MAIN ELECTRICAL

47 SFELEV

S-1 OCCUPANCY @ SHADED AREA4180 SF / 300 SF PER OCC14 OCCUPANTS

14DOOR

3" EXIT WIDTH REQUIRED33" PROVIDED

STAIR5" EXIT WIDTH REQUIRED

54" PROVIDED

90 FT TRAVEL DISTANCE < 100 FTMAX PER IBC TABLE 1021.2

SMOKE RESISTIVE ASSEMBLYPER IBC 509.4.1.

96 FT TRAVEL DISTANCE < 100 FTMAX PER IBC TABLE 1021.2

FEFE

FE

WATER ENTRY AREA,RE: PLUMBING

153 SFOFFICE

487 SFLARGE MEETING A

504 SFLARGE MEETING B

311 SFTOUR WAITING

88 SFSTORAGE

371 SF

HERITAGELOUNGE

108 SFOFFICE

100 SFOFFICE

128 SFBREAK

137 SFOFFICE

186 SF

CATERINGKITCHEN

53 SFCUSTODIAL

121 SFOFFICE

129 SFCONFERENCE

94 SFTELE

154 SFSTORAGE

170 SFOFFICE

107 SFOFFICE

107 SFOFFICE

167 SFOFFICE

66 SFELECT

108 SFCOPY/MAIL

264 SFWOMEN RR

186 SFMEN RR

111 SFOFFICE

107 SFOFFICE

382 SFCONFERENCE

108 SFOFFICE

42 SFSTORAGE

651 SFLOBBY

93 SFRECEPTION

1132

11

25

28

33

34

30

182

DOOR7" EXIT WIDTH REQUIRED33" PROVIDED

DOOR6" EXIT WIDTH REQUIRED33" PROVIDED

DOOR37" EXIT WIDTH REQUIRED

66" PROVIDED

DOOR32" EXIT WIDTH REQUIRED

66" PROVIDED

DOOR7" EXIT WIDTH REQUIRED

39" PROVIDED

LANDING - CONVERGING EXIT LOAD18" EXIT WIDTH REQUIRED

65" PROVIDED

B OCCUPANCY @ SHADED AREA6640 SF / 100 SF PER OCC67 OCCUPANTS

A-3 OCCUPANCY @ PUBLIC AREASEE PLAN FOR OCCUPANT LOAD

413 SF

TOURPRESENTATION

736 SFOPEN OFFICE

277 SFWAITING

632 SFOPEN OFFICE

47 SFELEV

187 SFSTAIR 1

441 SFLOBBY

88

184 SFSTAIR 2

FE FIRE EXTINGUISHERBELOW RECEPTIONDESK COUNTER

PROVIDE 1-HR RATEDFLOOR CONSTRUCTIONBELOW MECHANICALSHAFT EQ. TO UL D935

61

2015

DOOR4" EXIT WIDTH REQUIRED

33" PROVIDED

DOOR3" EXIT WIDTH REQUIRED

33" PROVIDED

SWINGING GATE AT LEVELOF EXIT DISCHARGE

160

33 35

171 SFOFFICE

121 SFOFFICE

127 SFWOMEN RR

130 SFBREAK ROOM

69 SFELECT

89 SFOFFICE

104 SFOFFICE

106 SFOFFICE116 SF

OFFICE

123 SFOFFICE

106 SFOFFICE

86 SFOFFICE

126 SFOFFICE

123 SFOFFICE

64 SFCUSTODIAL

118 SFOFFICE

210 SFMEETING

327 SFPHONE-A-THON

71 SFCOPY

102 SFUA STORAGE

171 SFFA STORAGE

100 SFIT STOR

96 SFTELE

95 SFCONFERENCE

108 SFOFFICE

52 SFMEN RR

101 SFOFFICE

41

DOOR9" EXIT WIDTH REQUIRED

33" PROVIDED

STAIR13" EXIT WIDTH REQUIRED

54" PROVIDED

40

DOOR8" EXIT WIDTH REQUIRED33" PROVIDED

STAIR12" EXIT WIDTH REQUIRED54" PROVIDED

B OCCUPANCY @ SHADED AREA8100 SF / 100 SF PER OCC81 OCCUPANTS

2368 SFOPEN OFFICE

418 SFHALL

331 SFHALL

187 SFSTAIR 1

47 SFELEV

98 SFOPEN OFFICE

184 SFSTAIR 2

REFER TO CODE ANALYSIS REPORT FOR GENERAL CODE INFORMATION.

THE CODE ANALYSIS PLANS INDICATE GENERAL LOCATIONS OF FIRERESISTIVE PARTITIONS AND SHAFTS.

ALL FIRE RESISTIVE CONSTRUCTION SHALL CONFORM TO THE APPLICABLEREQUIREMENTS OF THE REFERENCED FIRE RESISTIVE DESIGN ASSEMBLIES.

ALL HORIZONTAL AND/OR VERTICAL PENETRATIONS OF FIRE RESISTIVEASSEMBLIES SHALL BE FIRE STOPPED TO PROVIDE THE SAME LEVEL OF FIRERESISTANCE AS THE ASSEMBLY IN WHICH THEY OCCUR.

PROVIDE FIRE SAFING INSULATION BETWEEN EXTERIOR WALL FRAMING ANDFLOOR ASSEMBLIES TO PREVENT THE PASSAGE OF SMOKE AND FIRE AT THECONCEALED EXTERIOR WALL CAVITY.

1.

2.

3.

4.

5.

CODE ANALYSIS PLAN NOTES

SMOKE RESISTIVE ASSEMBLY PER IBC 508.2.5.2

CODE ANALYSIS PLAN LEGEND

2-HOUR RATED FIRE BARRIER

FE4A/60B/C FIRE EXTINGUISHER.

LOCATIONS TO BE VERIFIED PER THEINTERNATIONAL BUILDING, FIRE CODE & A.H.J.SEMI-RECESSED CABINETS TO PROTRUDE FROMWALL SURFACE NO MORE THAN 4" MAX.

1-HOUR RATED FIRE BARRIER

All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs

Issues/Revisions: Date:

SCD Project No.:

10/16/13SCHEMATIC DESIGN

02/07/14DESIGN DEVELOPMENT

04/04/1480% CD SET / PERMIT SET

05/02/14100% CD SET

WELCOME CENTER

A0.11

CODE ANALYSISPLANS

COLORADO SCHOOL OF MINESGOLDEN, CO

1219

3/32" = 1'-0"1

BASEMENT LEVEL CODE PLAN

3/32" = 1'-0"2

FIRST FLOOR LEVEL CODE PLAN

3/32" = 1'-0"3

SECOND FLOOR LEVEL CODE PLAN

Page 5: C1.00 COVER SHEET CURRENT/CSM WELCOME CENTER/01 Genera… · 100% cd set. 1 a101 sim a101 1 sim building section reference interior section detail reference centerline room identification

140 SFWOMEN RR

136 SFTELE

94 SFCUSTODIAL

77 SFELECT

142 SFMEN RR

124 SFOFFICE

125 SFOFFICE

147 SFOFFICE

173 SFOFFICE

136 SFCONFERENCE

133 SFCONFERENCE

91 SFCOPY

85 SFBREAK

102 SFWORK RM

93 SFCOPY/STOR.

427 SFOPEN OFFICE

108 SFOFFICE

108 SFOFFICE

422 SFOPEN OFFICE

166 SFWORK RM/CONF

107 SFOFFICE

117

118

DOOR24" EXIT WIDTH REQUIRED33" PROVIDED

STAIR36" EXIT WIDTH REQUIRED54" PROVIDED

DOOR24" EXIT WIDTH REQUIRED

33" PROVIDED

STAIR36" EXIT WIDTH REQUIRED

54" PROVIDED

B OCCUPANCY @ SHADED AREA7315 SF / 100 SF PER OCC74 OCCUPANTS

1294 SFOPEN OFFICE

477 SFHALL

443 SFHALL

187 SFSTAIR 1

184 SFSTAIR 2

263 SFHALL

128 SFOFFICE

168 SFOFFICE

214 SFWAITING

BALCONY - 804 SF161 OCCUPANTS /5 SF PER OCC

80

81

145 SFCONFERENCE

NO MECHANICAL EQUIPMENT TO BELOCATED WITHIN 10'-0" OF ROOF EDGE

RT

U, R

E: M

EC

H

SCREEN WALLAROUND ROOF TOPMECHANICAL UNIT

36"x36" ROOF ACCESSHATCH

48"x48" ROOFACCESS HATCH

14' - 5"

23' -

9"

OPENING IN SCREEN WALLFOR ROOF ACCESS

EXHAUST FAN, RE: MECH

REFER TO CODE ANALYSIS REPORT FOR GENERAL CODE INFORMATION.

THE CODE ANALYSIS PLANS INDICATE GENERAL LOCATIONS OF FIRERESISTIVE PARTITIONS AND SHAFTS.

ALL FIRE RESISTIVE CONSTRUCTION SHALL CONFORM TO THE APPLICABLEREQUIREMENTS OF THE REFERENCED FIRE RESISTIVE DESIGN ASSEMBLIES.

ALL HORIZONTAL AND/OR VERTICAL PENETRATIONS OF FIRE RESISTIVEASSEMBLIES SHALL BE FIRE STOPPED TO PROVIDE THE SAME LEVEL OF FIRERESISTANCE AS THE ASSEMBLY IN WHICH THEY OCCUR.

PROVIDE FIRE SAFING INSULATION BETWEEN EXTERIOR WALL FRAMING ANDFLOOR ASSEMBLIES TO PREVENT THE PASSAGE OF SMOKE AND FIRE AT THECONCEALED EXTERIOR WALL CAVITY.

1.

2.

3.

4.

5.

CODE ANALYSIS PLAN NOTES

SMOKE RESISTIVE ASSEMBLY PER IBC 508.2.5.2

CODE ANALYSIS PLAN LEGEND

2-HOUR RATED FIRE BARRIER

FE4A/60B/C FIRE EXTINGUISHER.

LOCATIONS TO BE VERIFIED PER THEINTERNATIONAL BUILDING, FIRE CODE & A.H.J.SEMI-RECESSED CABINETS TO PROTRUDE FROMWALL SURFACE NO MORE THAN 4" MAX.

1-HOUR RATED FIRE BARRIER

All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs

Issues/Revisions: Date:

SCD Project No.:

10/16/13SCHEMATIC DESIGN

02/07/14DESIGN DEVELOPMENT

04/04/1480% CD SET / PERMIT SET

05/02/14100% CD SET

WELCOME CENTER

A0.12

CODE ANALYSISPLANS

COLORADO SCHOOL OF MINESGOLDEN, CO

1219

3/32" = 1'-0"1

THIRD FLOOR LEVEL CODE PLAN

3/32" = 1'-0"2

ROOF LEVEL CODE PLAN

PLANNORTH TRUE

NORTH