~l! A2LACeI1iflCale No. 1750.02 Reference Material Producer CERTIFICA TE OF ANALYSIS Complies with ISO Guide 34, ISO Guide 31, ISO Guide 35, ISO 17025, ANSI/NCSL Z540-1, and ISO 9001 TRACEABLE@ CERTIFIED REFERENCE MATERIAL This certifica te indicates traceability to standards provided by (N1ST) National Institute of Standards and Technology and/or a National Standards Laboratory. Certificate No.: 4066-2978642 Conductivity Standard 100.1¡JS/cm Description: Catalog Number: Certificate Date: 4066 Lot: CC8710 June 17, 2010 Expiration Date: June 17, 2011 Certified Value: 100.1...S/cm U =:1:1.11 ...S/cm (k=2) at 25°C 100.1 micromho/cm, 9990ohm-cm, 66.7 PPM D.S. Derived Values: Certificationmeasurements are performed under ISO Guide34, A2LAaccreditation no. 1750.02 and are traceable to recognized national and international standards via an unbroken chain of comparisons. Electricalconductance is the reciprocal of electrical impedance. The International System of units (SI), derived unit of conductance, is Siemens (S), also referred to as (mhos) the reciprocal of ohms. The certified value is expressed in microsiemens per centimeter (¡JS/cm). MEASUREMENT: Ten (10) 100 mi samples were measured from this lot. The conductivity of each sample was derived from a measurement of the impedance of the solution using a conductivity meter and calibr.atedcell. The cell and sample were temperature controlled by submersion ina water bath at 25°C :1:0.0l5°C. UNCERTAINTY:The certified value is given as the average of the measured samples. The reported uncertainty (uc) is determined from the uncertainty of the measurement variation from sample to sample, change due to shelf life, and from the uncertainty of the measurement process. The value of uncertainty is multiplied by k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%. Uncertainty is calculated in accordance with the ISO IIGuide to the Expression of Uncertainty in Measurement" (GUM). METHOD: The certified reference material is prepared and analyzed by Control Company. The certified reference material consists of a mixture of a dilute solution of less than 0.01% (by mass) potassium chloride (KCL), of less than 2% (by mass) propanol, and of less than 99% (by mass) deionized water in equilibrium with atmospheric carbon dioxide. Mixing was performed by circulation utilizing a proprietary method. Will<w.~ ~~ Wallace Berry, Technical Manager Nicol Rodriguez, Quality Manager Traceability: Standards and Equipment Used Descrlptlon ConductivityStandard99.87 uS Serial Number Due Date Traceable Reference 10021101PTJ-5 8/12/10 CRM1002 Conductlvlty Probe (4W)/Meter 634-12-008 8/05/10 TC23-2724980 Dlgital Thermometer 22136727 6/30/10 4000-2344460 Temperature Callbratlon 6ath TC-191 A42238 Laboratory environment conditlons: 24.00C 37%RH 1,020mb/hPa Control Company -- 4455 Rex Road -- Friendswood, TX 77546 Tel: (281) 482 1714 Fax: (281) 482 9448 [email protected] www.controI3.com Control Company Is an ISO GUlde 34:2000 Certlfled Reference Material (CRM) Producer Accredlted by American Assoclatlon for Laboratory Accredltatlon (A2LA Certlflcate No. 1750.02). Certlflcate fulfllls the requlrements of ISO Gulde 31:2000 (Reference Materlals -Contents of Certlflcates and Labels), ISO Gulde 34:2000 "Quallty System Guldellnes for the Produetlon of Reference Materlals", and ISO Gulde 35:2006 "Certlflcatlon of Reference Materlals - General and Statlstlcal Prlnclpals". Control Company Is an ISO 17025:2005 Callbratlon Laboratory Accredlted by American Assoclatlon for Laboratory Accredltatlon (A2LA Certlflcate No. 1750.01). Control Company Is ISO 9001:2008 Certlfled by Det Norske Verltas (DNV Certiflcate No. CERT-0180S-2006-AQ-HOU-ANAB). TRACEABLE@ Is a reglstered trademark of Control 3 Inc. Page 1 of 3 Lot: CC8710 Copyright (e) 2009 Control Company

Upload: dangdang

Post on 14-May-2018

223 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Complies with ISO Guide 34, ISO Guide 31, ISO Guide 35 ...prug.espacios.net.mx/metrica/sitio/ftp/trazabilidad/4066-2978642.pdf · D A2LA Ce!1ilicate No. 1750.02 Reference Material

~l!A2LACeI1iflCale No. 1750.02

Reference Material Producer

CERTIFICA TE OF ANALYSISComplies with ISO Guide 34, ISO Guide 31,

ISO Guide 35, ISO 17025, ANSI/NCSL Z540-1, and ISO 9001TRACEABLE@ CERTIFIED REFERENCE MATERIAL

This certifica te indicates traceability to standards provided by (N1ST) NationalInstitute of Standards and Technology and/or a National Standards Laboratory.

Certificate No.: 4066-2978642

Conductivity Standard 100.1¡JS/cmDescription:

Catalog Number:

Certificate Date:

4066 Lot: CC8710

June 17, 2010 Expiration Date: June 17, 2011

Certified Value: 100.1...S/cm U =:1:1.11 ...S/cm (k=2) at 25°C

100.1 micromho/cm, 9990ohm-cm, 66.7 PPM D.S.Derived Values:

Certificationmeasurements are performed under ISO Guide 34, A2LAaccreditation no. 1750.02 and are traceable torecognized national and international standards via an unbroken chain of comparisons. Electricalconductance is the reciprocalof electrical impedance. The International System of units (SI), derived unit of conductance, is Siemens (S), also referred toas (mhos) the reciprocal of ohms. The certified value is expressed in microsiemens per centimeter (¡JS/cm).MEASUREMENT:Ten (10) 100 mi samples were measured from this lot. The conductivity of each sample was derived from ameasurement of the impedance of the solution using a conductivity meter and calibr.atedcell. The cell and sample weretemperature controlled by submersion in a water bath at 25°C :1:0.0l5°C.

UNCERTAINTY:The certified value is given as the average of the measured samples. The reported uncertainty (uc) isdetermined from the uncertainty of the measurement variation from sample to sample, change due to shelf life, and from theuncertainty of the measurement process. The value of uncertainty is multiplied by k=2, which for a normal distributioncorresponds to a coverage probability of approximately 95%. Uncertainty is calculated in accordance with the ISO IIGuide tothe Expression of Uncertainty in Measurement" (GUM).

METHOD: The certified reference material is prepared and analyzed by Control Company. The certified reference materialconsists of a mixture of a dilute solution of less than 0.01% (by mass) potassium chloride (KCL), of less than 2% (by mass)propanol, and of less than 99% (by mass) deionized water in equilibrium with atmospheric carbon dioxide. Mixing wasperformed by circulation utilizing a proprietary method.

Will<w.~ ~ ~Wallace Berry, Technical Manager Nicol Rodriguez, Quality Manager

Traceability: Standards and Equipment Used

Descrlptlon

ConductivityStandard 99.87 uS

Serial Number Due Date Traceable Reference

10021101PTJ-5 8/12/10 CRM1002

Conductlvlty Probe (4W)/Meter 634-12-008 8/05/10 TC23-2724980

Dlgital Thermometer 22136727 6/30/10 4000-2344460

Temperature Callbratlon 6ath TC-191 A42238

Laboratory environment conditlons: 24.00C 37%RH 1,020mb/hPa

Control Company --4455 Rex Road -- Friendswood, TX 77546Tel: (281) 482 1714 Fax: (281) 482 9448 [email protected] www.controI3.com

Control Company Is an ISO GUlde 34:2000 Certlfled Reference Material (CRM) Producer Accredlted by American Assoclatlon for LaboratoryAccredltatlon (A2LA Certlflcate No. 1750.02). Certlflcate fulfllls the requlrements of ISO Gulde 31:2000 (Reference Materlals -Contents ofCertlflcates and Labels), ISO Gulde 34:2000 "Quallty System Guldellnes for the Produetlon of Reference Materlals", and ISO Gulde 35:2006"Certlflcatlon of Reference Materlals -General and Statlstlcal Prlnclpals". Control Company Is an ISO 17025:2005 Callbratlon Laboratory Accredltedby American Assoclatlon for Laboratory Accredltatlon (A2LA Certlflcate No. 1750.01). Control Company Is ISO 9001:2008 Certlfled by Det NorskeVerltas (DNV Certiflcate No. CERT-0180S-2006-AQ-HOU-ANAB). TRACEABLE@ Is a reglstered trademark of Control 3 Inc.

Page 1 of 3 Lot: CC8710 Copyright (e) 2009 Control Company

Page 2: Complies with ISO Guide 34, ISO Guide 31, ISO Guide 35 ...prug.espacios.net.mx/metrica/sitio/ftp/trazabilidad/4066-2978642.pdf · D A2LA Ce!1ilicate No. 1750.02 Reference Material

DA2LA Ce!1ilicate No. 1750.02

Reference Material Producer

CERTIFICA TE OF ANALYSISComplies with ISO Guide 34, ISO Guide 31,

ISO Guide 35, ISO 17025, ANSI/NCSL Z540-1, and ISO 9001TRACEABLE@ CERTIFIED REFERENCE MATERIAL

PACKAGING:This material is available in both a 460 mi bottle and a 100 mi One-Shot™.

INTENDEDUSE:The certified reference material is intended for the calibration of conductivity cell constants, for conductivitymeasurement, for the validation of analytical methods, and for the preparation of working reference standards.

INSTRUCTIONSFOR USE: The certified reference material should be open for the minimum time. Rinse the cell in a smallamount of the certified reference material and discard. The recommended sample size for measurement is 100 mI. Discardthe standard after use and under the following circumstances: if the expiration date is past due, four months after opening, orif any color, turbidity, or visible microbiological growth become evident. Standards which have been opened are not protectedfrom growth.

Conductivityis sensitive to temperature, for measurements at a temperature other than 25°C, refer to the temperaturecorrection table provided.HOMOGENEITY:Ten (10) 100 mi samples were selected for analytical control. Results from different samples showed nostatistically significantdifferences, nor was there any correlation between values obtained and the bottling sequence.Bottle-to-bottle (One-Shot'Mto One-Shot™) variations of the samples measured are included as a part of the calculatedmeasurement uncertainty stated on page 1 of this certificate. A minimum sample size of 100 mi should be used to maintainthe certified value and the associa.ted statement of uncertainty. This standard as formulated is considered infinitelysoluble.STABILlTY,SHELFLIFE:The expiration date stated on page 1 indicates the period of time which the certified referencematerial in a properly packaged, unopened, unused, and stored under environmentally controlled and monitored conditionsremains withinthe specified uncertainty range.EXPlRATIONDATE:The date after which a certified reference material should be discarded.

STORAGE:Store below 40°C and above OOC.

SHIPPING: Ship below 50°C and above OOC.

MAINTENANCEOF CERTIFICATION:Control Company monitors representative samples from this lot over the period of itscertification. If a change occurs that affects the certification before the expiration date, Control Company posts amendedcertificates at www.controI3.com\crmupdate.htm.

MSDS INFORMATION: Please refer to the Material Safety Data sheet for information regarding this certified reference materialat www.controI3.com (Search MSDS). Use only the first four digits of the certificate number to locate the MSDS.

QUALITY STANDARD DOCUMENTATION:

ISO/lEC Guide 34:2000 General Requirements for the Competence of Reference Material Producers,accredited A2LACertificate Number 1750.02.

ISO Guide 31:2000 Reference Materials - Contents of Certificates and Labels.

ISO Guide 35:2006 Certification of Reference Materials - General and Statistical Principals.

ISO/lEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories,accredited A2LACertifica te Number 1750.01.

ANSI/NCSL Z540-1: 1994 Calibration Laboratories and Measuring and Test Equipment-General Requirements.

ISO 9001:2008 Quality Management System Registration -DNVCertificate Number CERT-01805-2006-AQ-HOU-ANAB

SUPPORTEDMETHODS:This certified reference material meets test requirements for Federal, State, and local agencies, CAP,CLSI, ACS, and CLlA. Traceable@ Certified Reference Material complíes with and is essential for use in these official methods:AOAC973.40, EPA120.1, Standard Method2510 (APHA,AWWA,WEF),ISO 7888, DIN38404, ASTMD1125, USGS1-1780,USP 645, OIMLR56, IUPAC, and for A2LA/NVLAPaccreditations /150 9000 certifications. Material may be used to calibrate allconductivity meters and to determine all conductivity cell constants.

Control Company -- 4455 Rex Road -- Friendswood, TX 77546Tel: (281) 482 1714 Fax: (281) 482 9448 [email protected] www.controI3.com

Control Company Is an ISO Gulde 34:2000 Certlfled Reference Material (CRM) Producer Accredlted by American Associatlon for LaboratoryAccredltation (A2LA Certiflcate No. 1750.02). Certiflcate fulfllls the requlrements of ISO Guide 31:2000 (Reference Materials -Contents ofCertiflcates and Labels), ISO Guide 34:2000 "Quallty System Guidellnes for the Production of Reference Materials", and ISO Guide 35:2006"Certiflcation of Reference Materials - General and Statistical Principals". Control Company is an ISO 17025:2005 Callbratlon Laboratory Accredltedby American Assoclation for Laboratory Accredltation (A2LACertlflcate No. 1750.01). Control Company is ISO 9001:2008 Certifled by Det NorskeVerltas (DNVCertiflcate No. CERT-01805-2006-AQ-HOU-ANAB). TRACEABLE@is a registered trademark of Control 3 Inc. .

Page 2 of 3 Lot: CC8710 Copyright (e) 2009 Control Company

Page 3: Complies with ISO Guide 34, ISO Guide 31, ISO Guide 35 ...prug.espacios.net.mx/metrica/sitio/ftp/trazabilidad/4066-2978642.pdf · D A2LA Ce!1ilicate No. 1750.02 Reference Material

~~A2LA Certificat. No. 1750.02Reference Material Producer

CERTIFICATE OF ANALYSISComplies with ISO Guide 34, ISO Guide 31,

ISO Guide 35, ISO 17025, ANSI/NCSL Z540-1, and ISO 9001TRACEABLE@CERTIFIED REFERENCE MATERIAL

Control Company -- 4455 Rex Road -- Friendswood, TX 77546Tel: (281) 482 1714 Fax: (281) 482 9448 [email protected] www.controI3.com

Control Company Is an ISO Gulde 34:2000 Certlfled Reference Material (CRM) Producer Accredlted by American Assoclatlon for LaboratoryAccredltatlon (A2LACertlflcate No. 1750.02). Certlflcate fulfllls the requlrements of ISO Gulde 31:2000 (Reference Materlals -Contents ofCertlflcates and Labels), ISO Gulde 34:2000 "Quallty System GuldellneS fer the Productlon of Reference Materials", and ISO Gulde 35:2006"Certlficatlon of Reference Materlals - General and Statlstlcal Prlnclpals". Control Company Is an ISO 17025:2005 Callbratlon Laboratory Accredltedby American Assoclatlon for Laboratory Accredltatlon (A2LA Certlflcate No. 1750.01). Control Company Is ISO 9001:2008 Certlfled by Det NorskeVerltas (DNVCertlflcate No. CERT-01805-2006-AQ-HOU-ANAB). TRACEABLE@Is a reglstered trademark of Control 3 Inc.

page 3 of 3 Lot: CC8710 Copyright (e) 2009 Control Company

Temperature Correctlon Informatlon _1.883 %

If your conductlvlty meter allows you to set a temperature coefflclent (temperature correctlon) then the underllned number shown abeve Is thebest approxlmatlon for thls speclflc analysls for thls speclflc Traceable@ Certlfled Reference Material. For more precise measurements use thechart. Use the chart below only If you are maklng absolute measurements. That 15,measurements wlthout any automatlc temperature correctlon(temperature coefflclent set to O). The chart below dlsplays derlved values.

Uslng a thermometer, measure the temperature of thls certlfled reference material. Shown on the chart Is temperature (In the far left column) Inwhole degrees. Shown across the top row 15temperature In tenths of a degree. Locate the measured temperature In whole numbers on the far leftcolumn, and then follow across the row to the temperature In tenths of a degree. At the Intersectlon Is the certlfled reference material value at thatspeclflc temperature. Standardlze your meter uslng that value. Example: Measured temperature Is 25.0oC. Flnd 25°C In the far left column, flndthe row O.ooC. Where 25°C and O.ooC Intersect, read the value In mlcroslemens/cm.

Temperature Correction Chart In microsiemens/cm

O.O.C O.l.C O.2.C O.3.C O.4.C O.S.C O.6.C O.7.C O.S.C O.9.ClS.C 81.9 82.1 82.3 82.4 82.6 82.8 83.0 83.1 83.3 83.516.C 83.6 83.8 84.0 84.2 84.3 84.5 84.7 84.9 85.0 85.217.C 85.4 85.6 85.7 85.9 86.1 86.3 86.4 86.6 86.8 87.0lS.C 87.1 87.3 87.5 87.7 87.9 88.0 88.2 88.4 88.6 88.819.C 88.9 89.1 89.3 89.5 89.7 89.8 90.0 90.2 90.4 90.620.C 90.7 90.9 91.1 91.3 91.5 91.7 91.8 92.0 92.2 92.421.C 92.6 92.8 92.9 93.1 93.3 93.5 93.7 93.9 94.0 94.222.C 94.4 94.6 94.8 95.0 95.2 95.4 95.5 95.7 95.9 96.123.C 96.3 96.5 96.7 96.9 97.1 97.2 97.4 97.6 97.8 98.024.C 98.2 98.4 98.6 98.8 99.0 99.1 99.3 99.5 99.7 99.92S.C 100.1 100.3 100.5 100.7 100.9 101.1 101.3 101.5 101.7 101.926.C 102.0 102.2 102.4 102.6 102.8 103.0 103.2 103.4 103.6 103.827.C 104.0 104.2 104.4 104.6 104.8 105.0 105.2 105.4 105.6 105.82S.C 106.0 106.2 106.4 106.6 106.8 107.0 107.2 107.4 107.6 107.829.C 108.0 108.2 108.4 108.6 108.8 109.0 109.2 109.4 109.6 109.830.C 110.0 110.2 110.4 110.6 110.9 111.1 111.3 111.5 111.7 111.931.C 112.1 112.3 112.5 112.7 112.9 113.1 113.3 113.5 113.7 113.932.C 114.2 114.4 114.6 114.8 115.0 115.2 115.4 115.6 115.8 116.033.C 116.3 116.5 116.7 116.9 117.1 117.3 117.5 117.7 117.9 118.234.C 118.4 118.6 118.8 119.0 119.2 119.4 119.7 119.9 120.1 120.33S.C 120.5 120.7 120.9 121.2 121.4 121.6 121.8 122.0 122.2 122.5