conometer 80 - westboro photonics...analysis areas of interest surface plot user defined angles...

4
VIEWING ANGLE PHOTOMETER KEY FEATURES Viewing Angle to +/- 80° Resolution of 0.22° 0.01 to 200 000 cd/m2 Luminance, Contrast and Gamma Modes Compact and Portable APPLICATIONS Flat Panel Displays Backlight Units WPHOTONICS.COM MEASURES MORE — AND FASTER Using the latest CMOS imaging technology, the CONOMETER ® 80 measures a wide range of luminance; from black levels to the brightest backlights and out to 80 degrees from normal. Measurements down to 0.01 cd/m 2 in are com- plete in under 3 seconds. The CONOMETER 80 is truly in a class by itself. SIMPLICITY Weighing just 450 g, the CONOMETER 80 can be easily integrated into any test scenario. The align- ment procedure is straightforward and assured. When placed directly at the display surface, the lens hood shields the test from stray light and conveniently sets the vertical measurement axis. ANALYSIS Using Photometrica ® software, users may quickly apply tools such as ellipses, polygons and profiles to evaluate display performance. A multiple of viewing angle measurements can be contained in a single measurement document. Derived data sets such as gamma, contrast and inversion are easily created. CUSTOMIZATION AND AUTOMATION With the Software Development Kit (SDK) script- ing within Photometrica is available to simplify the user interface, streamline repetitive tasks or integrate with external devices such as video processors. For full automation, users may cre- ate applications using SOAP (LabVIEW, MATLAB, etc.), or COM (C#, C++, VB). NEED COLOR? If luminance and color viewing angle measure- ments are required, then the WP214 imaging spectral colorimeter from Westboro Photonics is the solution. The WP214 has the same imag- ing features as the CONOMETER 80, but also includes tristimulus filtering and an integrated spectroradiometer — providing the highest mea- surement accuracy in its class. Fast and versatile viewing angle measurements for R&D and production CONOMETER 80 CONOMETER 80

Upload: others

Post on 25-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONOMETER 80 - Westboro Photonics...ANALYSIS AREAS OF INTEREST SURFACE PLOT User defined angles (AOIs) are plotted in the polar measurement and their statistics are reported in the

VIEWING ANGLE PHOTOMETER

KEY FEATURES

Viewing Angle to +/- 80°

Resolution of 0.22°

0.01 to 200 000 cd/m2

Luminance, Contrast and Gamma Modes

Compact and Portable

APPLICATIONS

Flat Panel Displays

Backlight Units

WPHOTONICS.COM

MEASURES MORE — AND FASTERUsing the latest CMOS imaging technology, the CONOMETER® 80 measures a wide range of luminance; from black levels to the brightest backlights and out to 80 degrees from normal. Measurements down to 0.01 cd/m2 in are com-plete in under 3 seconds. The CONOMETER 80 is truly in a class by itself.

SIMPLICITYWeighing just 450 g, the CONOMETER 80 can be easily integrated into any test scenario. The align-ment procedure is straightforward and assured. When placed directly at the display surface, the lens hood shields the test from stray light and conveniently sets the vertical measurement axis.

ANALYSISUsing Photometrica® software, users may quickly apply tools such as ellipses, polygons and profiles to evaluate display performance. A multiple of viewing angle measurements can be

contained in a single measurement document. Derived data sets such as gamma, contrast and inversion are easily created.

CUSTOMIZATION AND AUTOMATION With the Software Development Kit (SDK) script-ing within Photometrica is available to simplify the user interface, streamline repetitive tasks or integrate with external devices such as video processors. For full automation, users may cre-ate applications using SOAP (LabVIEW, MATLAB, etc.), or COM (C#, C++, VB).

NEED COLOR?If luminance and color viewing angle measure-ments are required, then the WP214 imaging spectral colorimeter from Westboro Photonics is the solution. The WP214 has the same imag-ing features as the CONOMETER 80, but also includes tristimulus filtering and an integrated spectroradiometer — providing the highest mea-surement accuracy in its class.

Fast and versatile viewing angle measurements for R&D and production

CONOMETER 80

CONOMETER 80

Page 2: CONOMETER 80 - Westboro Photonics...ANALYSIS AREAS OF INTEREST SURFACE PLOT User defined angles (AOIs) are plotted in the polar measurement and their statistics are reported in the

VIEWING ANGLE ANALYSIS

AREAS OF INTEREST

SURFACE PLOT

User defined angles (AOIs) are plotted in the polar measurement and their statistics are reported in the table

Surface plots for measurements of white, black and contrast

Page 3: CONOMETER 80 - Westboro Photonics...ANALYSIS AREAS OF INTEREST SURFACE PLOT User defined angles (AOIs) are plotted in the polar measurement and their statistics are reported in the

CONOMETER 80

PROFILES

Profiles may be applied and plotted for any measurements in the document. Left and center show profile locations for White and Black measurements and their corresponding luminance profiles on the right.

GAMMAPhotometrica supports full gamma analysis versus viewing angle.

Horizontal profile and 9 user defined AOIs are identified in the two-dimensional

measurement of a laptop display.

Gamma plot of 9 AOIs over 33 grey levels.

Red shaded areas exhibit gamma inversion (non-monotonic grey scale funciton).

Luminance plot of horizontal profile out to 80 degrees for 33 grey levels.

Page 4: CONOMETER 80 - Westboro Photonics...ANALYSIS AREAS OF INTEREST SURFACE PLOT User defined angles (AOIs) are plotted in the polar measurement and their statistics are reported in the

1505 CARLING AVE. SUITE 301 OTTAWA ON CANADA K1Z 7L9 TEL: 613 729 0614 WPHOTONICS.COM

CONOMETER 80

1505 CARLING AVE. SUITE 301 OTTAWA ON CANADA K1Z 7L9 TEL: 613 729 0614 WPHOTONICS.COM

SYSTEM RECOMMENDATIONS

• 2.0 GHz and 4 cores • 8 GB RAM • Windows 10, 64 bit • USB 3.1 port. (USB 3.1 PCIe card included with system)

MEASUREMENT AREAThe working distance can be varied to accommodate the pixel pitch of different displays. High resolution watches and cell phones can be measured with the lens almost touching the display glass to measure out to +/-80˚ in a 21 mm spot diameter. Laptop and tablet displays can use the integrated lens hood standoff to measure out to +/-80˚ with a 54 mm spot diameter. Large pixeled monitors and televisions can be measured at larger working distances with correspondingly larger spot sizes.

ORDERING INFORMATION

CONOMETER80 Conometer 80 for luminance and viewing angle measurements of displays. Includes Photometrica® software; 12 V power supply with international plug types; a storage case; USB3-PCIe interface card for desktop PCs; and a 3 meter USB3 Type-A to Micro-B cable with locking screws.

PM-DEV P Photometrica Software Development Kit for photometer automation clients such as MATLAB, C++/MFC and C#.NET, VB.NET, SOAP, LabVIEW and script writing capabilities

MEASUREMENT AREA DIAMETER

20° 40° 50° 60° 70° 80°

With lens touching LCD glass (mm) 3.2 6.4 8 11 16 21

Using lens hood (mm) 6.1 11 15 21 30 54

1 cm separation of lens hood (mm) 17 29 40 58 89 148

SPECIFICATIONS

Basic measurements Luminance

Units cd/m2, fL, user defined

A/D 12-bit

Viewing Angle, Resolution 80°, 0.22°

Luminance0.01 to 5 000 cd/m2 at f/1.8

0.4 to 180 000 cd/m2 at f/8

Dimensions (diameter, depth) 10 x 6 cm

Weight 450 g

Power Requirements 12 V, via GPIO or 5V via USB 3.1, 4W max.

Mounting Standard 1/4”-20

Computer Interface USB 3.1

Electrical Compliance CE and FCC Part 15 Class A

Warranty 2 years