digimerge dpv34dpc installation manual

32
Polaris Vision3 Day & Night Dome Camera P/N 01.BMS.11.0071401B V1.00

Upload: jmac-supply

Post on 12-Jan-2016

238 views

Category:

Documents


0 download

DESCRIPTION

Buy the Digimerge DPV34DPC at JMAC Supply.https://www.jmac.com/Digimerge_DPV34DPC_p/digimerge-dpv34dpc.htm?=scribd

TRANSCRIPT

Page 1: Digimerge DPV34DPC Installation Manual

Vandal Model: DPV34DIndoor Model: DPD34D

Polaris Vision3 Day & Night Dome Camera

INSTRUCTION MANUAL

Please read this manual thoroughly before use and keep it handy for future reference.

Polaris Vision3Day & Night Dome Camera

P/N 01.BMS.11.0071401BV1.00

Page 2: Digimerge DPV34DPC Installation Manual

Vandal Model: DPV34DIndoor Model: DPD34D

Polaris Vision3 Day & Night Dome Camera

INSTRUCTION MANUAL

Please read this manual thoroughly before use and keep it handy for future reference.

Page 3: Digimerge DPV34DPC Installation Manual

-i-

Page 4: Digimerge DPV34DPC Installation Manual

-ii-

Page 5: Digimerge DPV34DPC Installation Manual

the

-iii-

Page 6: Digimerge DPV34DPC Installation Manual

the

FEATURES

All Models Feature:• 1/3”SonyEx-View™II960H• 2.8-10.5mmVarifocalDay/NightLensF1.4DCIris• ExcellentlowlightperformanceusingPolarisVision3• 0.03Lux/F1.2(Color)• 0.00002Luxw/Sense-Upatx512• 700+TVlinesofresolution• 3DDigitalNoiseReduction(3D-DNR)• AdvancedShadowReduction(D-WDR)• OSDmenucontrol• PrivacyMasking/MotionDetection• VIDEOOUT(BNC)• Operatesin12VDCor24VAC• TestMonitorOutput(RCA)

DPD34D• IndoorDomeModel

• CameraMounting:Surface/Semi-FlushmountingDPV34D

• VandalDomeModel• CameraMounting:SurfaceMounting• WeatherproofRated(IP66)

General DPD34D DPV34D

Power source DC 12V / AC 24V +10%Power consumption 2.5Watt MaxMinimum Power Requirement 191mA DC / 150mA AC

Image sensor 1/3” Sony Ex-View™ II 960HTotal pixels 976 (H) x 494 (V)Scanning system 2:1 interlaceScanning frequency 15.734KHz(H), 59.95Hz(V)Sync.system Internal / Line LockResolution 700+ TV LinesMin.illumination 0.00002 LUX (F1.2) Slow Shutter (x512)Video output 1.0 Vp-p (75 ohm, composite)S/N Ratio more than 50dB (AGC OFF)Power input 2-Pin terminal block (Detachable)Video output BNC Connector (2nd video RCA)Lens mount Fixed mountLens 2.8 - 10.5mm F1.4 Varifocal DC Auto irisOperating temperature -10~50°COperating humidity 0-90% RH

SPECIFICATIONS

-1-

Page 7: Digimerge DPV34DPC Installation Manual

-2-

MEASUREMENTS

Vandal Dome Dimensions

112 mm4.4 in

97.0 mm3.82 in

Base hole positions

40 mm1.57 in

55.5 mm2.19 in

Ø 0.1"3.5 mm

3.9"100.0 mm

3.4"87 mm

5.1"130 mm

112 mm4.4 in

Indoor Dome Dimensions

5.1"130 mm

39 mm1.5 in

115 mm4.5 in

27 mm1.1 in

137°123°

100°

7 mm.28 in

Underside Base hole positions

Recess cutout and tting clearance.Recess Mount Fitting dimensions

Page 8: Digimerge DPV34DPC Installation Manual

-3-

PACKING CONTENTS

Junction box plate allows fitting of either Vandal dome or Indoor dome to standard 2S, 4S and Octagon junction boxes.

Junction Box fitting plate accessories:

Junction Box Fiting plate -------------------------1 2S / 4S plate screws (KM3.5 Type) ------------4 Octagon fitting screws (KM4 Type) -------------2 Base Fitting Screws PWM3 ----------------------3

JUNCTION BOX PLATE

Screw hole overview Camera base tting illustration Junction box tting plate attached to camera

Base FittingScrews

88.9 mm3.5 in

83.3 mm3.28 in

46.0 mm1.8 in

Base Fitting Screw.

Octagon Screw

2S / 4SScrew

Indoor Dome package contains the following:

Camera in housing ---------------------------------1 Camera Locking screws (PA3 Type) -----------2 Instruction guide (This Document) -------------1 Surface & Flush Mounting Templates----------2 RCA - BNC test cable ------------------------------1 Junction Box Plate ----------------------------------1 Mounting screw pack ------------------------------1 Vandal Dome package contains the following:

Camera in housing ---------------------------------1 Camera Locking screws (PM4 Type) ----------3 Instruction guide (This Document) -------------1 Surface Mounting Template ----------------------1 RCA - BNC test cable ------------------------------1 Junction Box Plate ----------------------------------1 Mounting screw pack ------------------------------1 Tamper allen key ------------------------------------1 Conduit Key ------------------------------------------1

LockingScrew

ConduitKey

Allen Key

Mounting Screws Pack.3pc 70mm / 2.8in Screws3pc 30mm / 1.2in Screws

3pc 40mm 1.6in plugs

Page 9: Digimerge DPV34DPC Installation Manual

-4-

JUNCTION BOX INSTALLATION TYPES

2S FITTINGa. 2S Fitting requires only 2pcs of 2S/4S screws.

Note: You have a reduced space in which to hide cables using this type of installation. Recommended for indoor dome only.

TWO GANG FITTINGa.

of 2S/4S screws. Note: A two gang provides the most robust

vandal domes.

4S FITTINGa. 4S Fitting requires 2pcs of 2S/4S screws.

Note: Suitable for both indoor and vandal domes.

OCTAGON FITTING

a. Octagon screws.

Note: are larger compared to those used for the 2S/4S (M4 type). Suitable for both indoor and vandal domes

Cable Entry

Screws

Cable Entry

Screws

Cable Entry

Screws

Cable Entry

Screws

Page 10: Digimerge DPV34DPC Installation Manual

-5-

VANDAL DOME FITTINGS

Pendant Cap - model # MNTV2XPCReplaces the need for the camera base.Compatible with ceiling conduit installations.

Pole Mount - model # MNTV2XP

Junction Box Attachment for MNTV2XW & MNTV2XC - model # MNTV2XJFits either wall mount and ceiling mount. Symmetrical design - reversible for top or bottom conduit.

Corner Mount bracket - model # MNTV2XR

Pendant Mount - model # MNTV2XCWall Mount - model # MNTV2XW

Junction Box Mount - model # MNTV2XB

Can fit either MNTV2XW or MNTV2XJ. Can fit either MNTV2XW or MNTV2XJ.

Mount for either Vandal or Indoor Dome.Can also mount MNTV2XC or MNTV2XW.

Page 11: Digimerge DPV34DPC Installation Manual

-6-

INSTALLATION. VANDAL DOME1) Loosen the three tamper screws using the provided

allen key. Lift the dome cover.Note: If you plan to use conduit fitting, remove conduit

cap using the provided conduit key.

3a) Reinsert camera module into camera base by aligning the arrow notches on the edge of the camera module and the camera base (label on edge of camera module indicates the location of the arrow notch), and turning camera module clockwise to lock into place.

3b) Use the 3 base locking screws to secure camera base to camera module.

Go to step 4 on page 7 to complete installation.

Method 1 - Direct Attach Install2a) Use the included mounting template (Installation

Option 2) to mark and pre-drill the required holes. Remove 2 of the 3 base locking screws. Use 2pc of the 2.8” screws to mount the camera directly to the mounting surface.

Remove the 3rd base locking screw and install the 3rd 2.8” screw.

Go to step 4 on page 7 to complete installation.ORMethod 2 - Camera Base Install2b) Use the included mounting template (Installation

Option 1) to mark and pre-drill the required holes.Remove the camera base by unscrewing the 3 base locking screws, and turn camera module approx. 5 degrees counter-clockwise to detach camera base from the camera module. Install the base to the correct holes as indicated on the mount template using the 1.2” screws. Go to step 3a.

Method 3 - Junction Box Install2c) Attach provided fitting plate to junction box

(see page 4 for details). Remove the camera base by unscrewing the 3 base locking screws, and turn the camera module approx. 5 degrees counterclockwise to detach camera base from camera module. Install the base to the junction box using the base attachment screws. Go to step 3a.

Installation Option 1:Use holes marked with 'A' when

installing camera base first. Use short 30mm screws and anchors.

Installation Option 2:Use holes marked with 'B' when

installing complete camera housing. Use long 70mm screws and anchors.

A

A

A

B

B

B

1

3

a

b

a

b

2

Mounting Template Conduit Key Allen Key

Page 12: Digimerge DPV34DPC Installation Manual

-7-

INSTALLATION. VANDAL DOME

7a) Re-attach the dome cover. Align arrows according to the diagram below to ensure a weatherproof seal.

7b) Use the allen key to tighten the tamper screws.Note: Make sure dome cover cord does not get caught in

the rubber seal.

6a) Adjust camera viewing angle and secure into place by tightening thumb screw using a flat head screwdriver.

Note: Lens adjustment levers are by default in the locked position. Turn counter clockwise to unlock. Tighten levers to secure lens setting.

6b) Adjust lens and OSD as required.6c) Re-attach the camera cover, using the thumb screw

as a guide, until it snaps into place.

5) Insert the included video test cable into the RCA jack and connect to a test monitor to set up camera.

4) Remove camera cover by squeezing the back and front of the cover (as indicated by the arrow indicators) at the same time and lifting it up and away from the lens.

1 2

3

7

5

6

4

Arrow

Video test cable

RCA JackZoom

Thumb Screw

Focus

Arrow on camera base

Correct arrow alignment

Arrow on camera module (inside camera)

Arrow on dome cover.

1

2

3

Page 13: Digimerge DPV34DPC Installation Manual

-8-

INSTALLATION. INDOOR DOME (Surface Fitting)

1a) Press down on the tab marked with an arrow to lift up the dome cover slightly

1b) While pressing on tab, twist the dome cover counter clockwise just a few degrees to release dome cover from back clips.

Lift off the cover.

3a) Reinsert camera module into camera base by aligning the arrow notches, and turning camera module clockwise to lock into place.

3b) Reinstall the base locking screws. (indicated by padlock markings)

Go to step 3 on page 9 to complete installation.

Method 1 - Direct Attach Install2a) Use included mounting template to mark and pre-

drill the required holes. Use included 2.8” screws to mount the camera directly to the mounting surface.

Go to step 3 on page 9 to complete installation.OR Method 2 - Camera Base Install2b) Use the included mounting template (Installation

Option 1) to mark and pre-drill the required holes. Remove the camera base by unscrewing the base locking screws (indicated by padlock markings) and turn camera module approx. 5 degrees counterclockwise to detach camera base from the camera module. Install the base as indicated using the 1.2” screws. Go to step 3a.

Method 3 - Junction Box Install2c) Attach provided fitting plate to junction box

(see page 4 for details). Remove the camera base by unscrewing the 3 base locking screws, and turn the camera module approx. 5 degrees counterclockwise to detach camera base from camera module. Install the base to the junction box using the base attachment screws. Go to step 3a.

1

3

a

a

b

a

b

b

2

Page 14: Digimerge DPV34DPC Installation Manual

-9-

INSTALLATION. INDOOR DOME (Semi-Flush Fitting)

1a) Press down on the tab marked with an arrow to lift up the dome cover slightly

1b) While pressing on tab, twist the dome cover counter-clockwise to release dome cover

1c) Remove the camera base by unscrewing the base locking screws (indicated by a padlock markings) and turn camera module approx. 5 degrees counter-clockwise to detach camera base from the camera module.

a) Cut semi flush mounting hole into surface using provided Semi-flush Mount Cut-out Template.

Note: Always cut using the inside line of the cutout template

b) Insert camera into cutout. Make sure that the mounting arms are not extended.

c) Turn screwdriver clockwise to unlock all of the 3 mounting arms.

d) Continue turning clockwise to move mounting arms down until they make contact with inner mounting surface.

Note: Once mounting arms have made contact with the inner mounting surface, do not apply too much pressure to avoid damaging surface.

a) Re-attach the camera cover, using the thumb screw as a guide, until it snaps into place. b) Reattach dome cover.

a) Remove camera cover by squeezing the back and front of the cover as indicated by the arrow indicators at the same time and lifting it up and away from the lens.

b) Insert the included video test cable into the RCA jack and connect to a test monitor to set up camera. (see page 10).

c) Adjust camera viewing angle and secure into place by tightening thumb screw using a flat head screwdriver. Adjust lens and OSD as required.

Note: Lens adjustment levers are by default in the locked position. Turn counter clockwise to unlock. Tighten levers to secure lens setting.

Thumb Screw

1

ab

dc

b

4

2

3

ZoomFocus

Page 15: Digimerge DPV34DPC Installation Manual

-10-

CAMERA ADJUSTMENT

OSD function joystick. Pressing down on joystick acts as ENTER function.

RCA Service ConnectorUse supplied RCA - BNC cable If you require BNC output.

MENU TREE SUMMARY

EXPOSURE • AUTO • HIGH LUMINANCE • MODE • BRIGHTNESS • LOW LUMINANCE • MODE

• AGC MAX

• DSS MAX • MANUAL • MODE • SHUT • AGCPIC ADJUST • MIRROR • DIS • EZOOM • LEVEL • SHARPNESS • HUE • B-GAIN • R-GAIN • ZOOM • PAN • TILTWHITE BAL • ATW • SPEED • DELAY CNT • ATW FRAME • ENVIRONMENT • PUSH • USER1/USER2 • ANTI CR • PUSH LOCK

• B-GAIN • R-GAINWDR • MODE • LEVEL • HLC • CLIP LEVEL • SCALE • BLC DNR • DNR MODE • LEVELDAY / NIGHT • AUTO • BURST • DELAY CNT • DAY> NIGHT • NIGHT> DAY • BW • COLOR • EXT • SMAR T IR • MODE • LEVEL • GAMA OPT

PRIVACY • AREA SEL • MODE • POSITION • COLOR • TRANSP • MOSAICMOTION DET• MOTION DET • DETECT SENSE • BLOCK DISP • DETECT AREA • MONITOR AREAOTHERS • LANGUAGE • LENS • AUTO • MANUAL • TYPE • MODE • SPEED • SYNC • CAMERA TITLE • WPC • VERSION • CAMERA RESET • INT • LL*

*LL (Line Lock) sub-menu is only shown when the camera is connected to AC power.

Page 16: Digimerge DPV34DPC Installation Manual

-11-

CAMERA ADJUSTMENT

OSD MENU control

Pressdownonthefunctionjoysticktoaccessthesetupmenu.Joystickhas4directional buttons. Press down on the middle of the joystick to select menuoptions.

•Mainsetupmenuisdisplayedonthemonitorscreen.

SETUP MENU

SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

Selectfunctionsbymovingthejoystickupanddown.Movethejoystickleftandright to change setting values. Press on joystick to confirm selection.Ifamenuoptionfeaturesa , a sub menu is available which can be accessedby pressing down on the joystick.

Onceyouhavefinishedupdatingsettings,highlightSAVEALLandpressdownonthejoystick.Then,highlightEXITandpressdownonthejoystick.IfyoudonotselectSAVEALL,settingschangeswillbelostwhenthecameraisrebooted.

Page 17: Digimerge DPV34DPC Installation Manual

-12-

CAMERA ADJUSTMENT

EXPOSURE

SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

ChangestheoutputexposuresettingsachoiceofAUTO(default)orMANUAL.

•  AUTO

AUTO SETUP

HIGH LUMINANCE MODE AE+AUTO IRISBRIGHTNESS 032 LOW LUMINANCE MODE AGC>DSSAGCMAX 098DSS MAX X4 RETURN

HIGH LUMINANCEMODE: AE+AUTO IRIS / ME+AUTO IRIS

BRIGHTNESS: 000-255 Brightnesslevelofoperatingmodeassetabove. Defaultsettingis128LOWLUMINANCEMODE: AGC/ SLOW / AGC-DSS / AGC-DSS-AGC / OFF SettingsavailableonlywhenusingDClens. AGCMAX: 000-255 Brightnesslevelofoperatingmodeassetabove. Defaultsettingis098DSS MAX: X1-512

Page 18: Digimerge DPV34DPC Installation Manual

-13-

CAMERA ADJUSTMENT

MANUAL SETUP

MODE SHUTSHUT 1/60 (S)AGC 6 (DB) RETURN

•  MANUALMODE: SHUT / SLOW Letsyouselectcombinationofexposuremodes.

SHUT: WhenMODEissettoSHUT,selectshutterspeedinx/ second 1/60,1/100,1/250,1/500,1/1000,1/2000, 1/4000,1/10000 Default setting is 1/60

SHUT: WhenMODEissettoDSS Theshutspeedcanbe2,4,8,16,32,64,128,256 Default setting is 2

AGC: SetafixedgainvaluefortheAGCdb 6,12,18,24,30,36,42,44.8

Page 19: Digimerge DPV34DPC Installation Manual

-14-

CAMERA ADJUSTMENT

PICT ADJUST

SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

Picture and display control settings

PICT ADJUST

MIRROR OFFDIS OFFEZOOM LEVEL 032SHARPNESS 009HUE 042R-GAIN 104B-GAIN 176 RETURN

•  MIRROR: OFF/V-FLIP/H-FLIP/HV-FLIP Horizontallyandverticallyflipthedisplayoutput.•  DIS: ON / OFF Enable/DisableDigitalImageStabilization.•  EZOOM

EZOOM SETUP

ZOOM 000PAN 512TILT 256 RETURN

Page 20: Digimerge DPV34DPC Installation Manual

-15-

CAMERA ADJUSTMENT

ZOOM: 000-255 Default 0 PAN: 000-1023 Default 512 TILT: 000-512 Default 256

Note: Zoom must be higher than 0 to use Pan and Tilt settings.•  LEVEL: 000-063 Screen brightness.•  SHARPNESS: 000-015 Screen sharpness.•  HUE: 000-100 AdjusttheHUEvalue•  R-GAIN: 000-255 AdjusttheREDgain.•  B-GAIN: 000-255 AdjusttheBLUEgain.

WHITE BAL

SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

WhiteBalancecanbesettofollowing: ATW/PUSH/USER1/USER2/ANTICR /PUSHLOCK•  ATW (Auto Trace White Balance)

ATW SETUP

SPEED 002DELAY CNT 002ATW FRAME x0.5ENVIORMENT INDOOR RETURN

SPEED: 000-255 SpecifiestheAEcontrolforATW Defaultsettingis239DELAY CNT: 000-255 SetsthetimebasedofATW change.Defaultsettingis16

Page 21: Digimerge DPV34DPC Installation Manual

-16-

CAMERA ADJUSTMENT

ATW FRAME: x0.50 / x1.00 / x1.50 / x2.00 Sets pull in frame for magnification DefaultsettingisX0.50ENVIRONMENT: INDOOR/OUTDOOR SetthepullinframeofATW DefaultsettingisOUTDOOR•  PUSH Use white balance regardless of the subject conditions.•  USER1/2 User defined Blue and Red gain adjustment

USER1 WB

B-GAIN 029R-GAIN 034 RETURN

USER2 WB

B-GAIN 045R-GAIN 038 RETURN

B-GAIN: 000-255BGainadjustmentforWBR-GAIN: 000-255RGainadjustmentforWB

•  ANTI CR Activatescolorrollingsuppression.•  PUSH LOCK Press down on joystick to set current scene as the white balancelevel.Placea18%graycardinfrontofthelens andselectPUSHLOCKforanaturalwhitelevel.

Page 22: Digimerge DPV34DPC Installation Manual

-17-

CAMERA ADJUSTMENT

WDR

SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

WideDynamicRange.

WDR SETUP

MODE OFFLEVEL -HLC OFFCLIP LEVEL 000SCALE 010BLC OFF RETURN

•  MODE: OFF / D-WDR E:OFF/D-WDR D-WDR: Gammacurve,high&lowluminanceadjusted DefaultisOff HLC: OFF/ON/AUTOHighlightcompensation. CLIPLEVEL:000-255Clippinglevel.Defaultsettingis0 SCALE:000-015 BLC:OFF/ONBLCcanbeenabledwithWDROFFonly

DNR

SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

DigitalNoiseReduction.Thisfunctionreducesthebackgroundnoiseinalowluminanceenvironment.

Page 23: Digimerge DPV34DPC Installation Manual

-18-

CAMERA ADJUSTMENT

DNR

DNR MODE 3DLEVEL LOW RETURN

•  DNR MODE: 2D+3D / 3D / 2D / OFF NoisereductionFiltermode.LEVEL: OFF/LOW/MIDLOW/MID/MIDHIGH/HIGH Adjustmentofthefilterstrength. Default setting is LOW

DAY/NIGHT AUTO / BW / EXT /COLOR SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

Day/Nightmodecanbesettothefollowingoptions:COLOR/AUTO/EXT/BW.SelectCOLORforacolorimageorBWforblackandwhite.EXTallowstheuseofanexternaltriggertoactivateday/nightoperation.UseAUTOtohavethecameraautomaticallyadjustforDay/Nightmode.

DAY/NIGHT

BURST OFFDELAY CNT 003DAY - NIGHT 002NIGHT - DAY 005 RETURN

Page 24: Digimerge DPV34DPC Installation Manual

-19-

CAMERA ADJUSTMENT

•  AUTOBURST: ON/OFF Selects whether to output the burst signal when night mode has been identified.DELAY CNT: 000-255 Night/Dayidentificationtransfertime.DAY - NIGHT: 000-255 ThresholdforNightstatusfromdaystatus.NIGHT - DAY: 000-255 ThresholdfortheDaystatusfromnight status.

•  BW SETUP: AllowsadditionalSmartIRsettingstobeenabled.

B/W SETUP

SMART IR ON RETURN

SMART IR SETUP

MODE AUTOLEVEL 015GAMA OPT ON RETURN

MODE: AUTO/CENTER

SMART IR AREA

TOP 001BOTTOM 009LEFT 001RIGHT 017 RETURN

Center option under mode allows the user to define a rectangular areafor the Front Light Compensation.

Page 25: Digimerge DPV34DPC Installation Manual

-20-

CAMERA ADJUSTMENT

PRIVACY OFF / ONSETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

Hideanareasothatitisnotdisplayedonthemonitor.

PRIVACY

AERA SEL 1 / 15MODE OFFPOSITION -COLOR -TRANSP -MOSAIC - RETURN

AREA SEL: Select the privacy area to be adjusted.MODE: OFF/ON WhenONthesettingsbelowcanbechanged Default OFF for all Areas

PRIVACY

AREA SEL 1 / 15MODE ONPOSITION COLOR WHITETRANSP 1.00MOSAIC - RETURN

Page 26: Digimerge DPV34DPC Installation Manual

-21-

CAMERA ADJUSTMENT

POSITION: Whenselectedareaselectionscreenappears:

NEXT: PUSH ENTER

Move the joystick to move the corners (you can create any 4-sided shape). The selected side is highlighted by a small box. To select the next corner, press ENTER. To return to privacy menu, press enter repeatedly. COLOR: BLACK,RED,GEEEN,BLUE,YELLOW,CYAN,MAGENTA, WHITE.Setsthecolorsofthemaskframes.

TRANSP: 1.00/0.75/0.50/0.00Setstheprivacyarea transparency.

MOSAIC: ON/OFFSetstheprivacymaskasmosaic. MOSAICisnotavailableifTRANSPis1.00

MOTION DET SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

Themotiondetectionareasofthescreenarebrokeninto24x16rectangularblocks.UseMONITORAREAtoconfigurealways-onmotionalertareasonthescreen.

Page 27: Digimerge DPV34DPC Installation Manual

-22-

CAMERA ADJUSTMENT

MOTION DET

MOTION DET OFFDETECT SENSE 111BLOCK DISP OFFDETECT AREA MONITOR AREA RETURN

MOTION DET: OFF/ON.Turnonoroffthemotiondetection. Default is OFFDETECT SENSE: 0-127Setsthemotiondetectionsensitivitylevel.BLOCK DISP: ON/OFF:Displaysblocksinareaswheremotionis detected.DETECT AREA: Selectareaofthescreentoenable/disablemotion detection.

DETECT AREA

EXIT: HOLD ENTER

Bydefaulttheentireareaisenabledfordetection.Usingthemovementarrowsyoumovethe2x2sizeblockpositionsaroundthescreen.Presstheenterbuttontotogglethisareatoenable/diablemotiondetection.Holddowntheenterbuttonto return to the motion detection menu.

Gridareas:MotiondetectionenabledTransparent:Motiondetectiondisabled

Page 28: Digimerge DPV34DPC Installation Manual

-23-

CAMERA ADJUSTMENT

MONITOR AREA : Allowsyoutoconfigureupto4motiondetectionareas.Areaswillbehighlightedonthescreenandflashwhenmotionisdetectedwithinthem.AreaswillnotflashifmotionisdetectedinareasthathavebeendisabledusingDETECTAREA.

MONITOR AREA

AERA SEL 1 / 4MODE OFF TOP 000 BOTTOM 000 LEFT 000 RIGHT 000 RETURN

AREA SEL: 1/4,2/4,3/4,4/4 Select area to adjust. Whenenabled,theboxcolorsare: 1Pink,2Green,3Blue,4Yellow Whenareasoverlap,theareawiththelowestnumber takes priority

MODE: OFF/ON. Disable / Enable areaTOP: 000-015 Position of the top of the areaBOTTOM: 000-015 Position of the bottom of the areaLEFT: 000-023 Position of the left side of the areaRIGHT: 000-023 Position of the right side of the area

Note:TOPvaluecannotbegreaterthanBOTTOM,andLEFTcannotbegreaterthanRIGHT.Numbersautomaticallyupdatetopreventinvalidpositions.

Gridareas:MotiondetectionenabledTransparent:Motiondetectiondisabled

Page 29: Digimerge DPV34DPC Installation Manual

-24-

CAMERA ADJUSTMENT

OTHERS SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

Miscellaneouscamerafunctions.

OTHERS

LANGUAGE ENGLISHLENS AUTOSYNC INTCAM TITLE OFFWPC

VERSION

CAMERA RESET

RETURN

•  LENS MANUAL / AUTO AUTO IRIS

TYPE DCMODE AUTOSPEED 064 RETURN

MODE: AUTO,OPEN,CLOSE Sets the mechanical iris control mode. SPEED: 000-255 Sets the convergence speed of the mechanical iris.

Page 30: Digimerge DPV34DPC Installation Manual

(Advanced function; not for normal use)

-25-

CAMERA ADJUSTMENT• CAM TITLE OFF / ON Select a camera title to be shown on the screen.

CAMERA TITLE SETUP CAMERA ABCDEFGHIJKLMNOPQRSTUV WXYZ0123456789-!#$%&’ ()_`.:;<=> @^*./^*X+/ CHR1 CHR2

CLR POS RETURN

• WPC WPC

PLEASE COVER THE LENSENTER PW RETURN

The WPC (White Pixel Compensation) features is used to correct the CCD if dead pixels are visible. You must cover the lens completely so no light can enter the camera sensor for WPC to work. Press the up, down, left, right, middle button to start the highlight of compensation. When prompts

Use Up/Down/Left/Right to move around. CLR will clear info. POS allows you to change the title position.

SYNC•

SYNCPHASE UP PUSH ENTERPHASE DOWN PUSH ENTER RETURN

Camera uses internal sync (INT) when camera is connected to DC power.Line Lock (LL) is used when camera is connected to AC power. If you notice color rolling when the camera is connected to AC power, select LL then select PHASE UP or PHASE DOWN and press ENTER to adjust the phase.

Page 31: Digimerge DPV34DPC Installation Manual

-26-

CAMERA ADJUSTMENT

•  VERSION Givesversioninformationregardingcurrentcamera software.

VERSION INFO

MCU VER V1.0.0 NORMALROM VER V1.0.0

RETURN

•  CAMERA RESET Thiswillresetallsettingsforallmenustomanufacturer defaults.

EXIT / SAVE ALL SETUP MENU

EXPOSURE AUTOPICT ADJUST WHITE BAL ATWWDR DNR DAY/NIGHT AUTOPRIVACY MOTION DET OTHERS EXIT SAVE ALL

•  EXIT ExitOSDmenu. Exitwillkeepanychangesonlyuntilcamerais powered off.

•  SAVE ALL Saves the settings to camera Settings are retained after camera power loss.

Page 32: Digimerge DPV34DPC Installation Manual

TROUBLESHOOTING

Followthestepsbelowifyouareexperiencingtroublewithyourcamera.ContactDigimergeTechnicalSupportiftheissuepersists.

•  Nothing appears on the screen. ¤ Checkthatthepowercableisconnectedproperlyandthatthevoltageiscorrect. ¤ CheckthatyouhaveproperlyconnectedVIDEOcabletothecameraVIDEOoutputjackandto

themonitor/DVR.

•  The image on the screen is unclear. ¤ Isthelensordomecoverstainedwithdirt?Cleanlensordomecoverwithsoft,cleancloth. ¤ Re-positionthecameraifnecessary. ¤ AdjusttheZoomandFocusscrewsasneeded.

•  The image on the screen is dark. ¤ Ifyouhaveanintermediatedevice,settheimpedanceto75Ω/Hi-z. ¤ Adjustthemonitorcontrast&brightnesscontrols.

•  Image quality is poor. ¤ ReturnthecameraOSDtofactorydefaultsettings(OSDMenu>OTHERS>CAMERARESET). ¤ Verifythatthecameraisreceivingsufficientpower.

•  There is interference in the image. ¤ Thecameraorthecablesmaybeclosetoasourceofhighvoltage,suchasagenerator.Re-

position the camera if necessary.

When the resistance value of copper wire is at [20˚C(68˚F)]

Copper wire size (AWG) #24(0.22mm2) #22(0.33mm2) #20(0.52mm2) #18(0.83mm2)Resistance (Ω/m) 0.078 0.050 0.030 0.018Voltage Drop (V/m) 0.028 0.018 0.011 0.006

Asshowninthetableabove,voltagedecreasesasthewiregetslonger.Thereforeuseofanexcessivelylongadapteroutputlineforconnectiontothecameramayaffecttheperformanceofthe camera.

*Standardvoltageforcameraoperation:DC12V±10%orAC24V±10%*Theremaybesomedeviationinvoltagedropdependingonthetypeofwireandthemanufacturer.

• Be sure to connect power only after all the installation is complete.• Use the UL listed, CLASS 2 power transformer for 12v DC or 24v AC adapter.

-27-