PMP 33RD MEETING
Institute for Energy and Transport
Joint Research Centre
B. Giechaskiel, G. Martini
30 Sept 2014
![Page 2: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/2.jpg)
Outlook
• Regeneration • Sub23nm
• Status / Need of change? • Vehicles • PN systems
• Catalytic Stripper (CS) • Calibration
• Status / Need of change? • PNC • VPR
![Page 3: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/3.jpg)
Calibration
![Page 4: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/4.jpg)
Calibration topics overview
• Is there a need? • Status PNC • Status VPR • Open issues VPR
![Page 5: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/5.jpg)
PN systems: Comparability
From ±30% (PMP) to ±15% (R83, 49)
![Page 6: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/6.jpg)
FVV: HD partial flow systems
![Page 7: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/7.jpg)
FVV: PN systems comparability
±15-20%
![Page 8: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/8.jpg)
FVV: Influencing factors
• Partial flow system response ±4%
• Partial flow system calibration and losses ±4%
• PN system calibration ±7-12%
![Page 9: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/9.jpg)
FVV: Calibration of systems
10-15% improvement can be achieved (BOTH VPR and PNC)
![Page 10: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/10.jpg)
PNC calibration
![Page 11: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/11.jpg)
PNCs (CPCs) status
• Legislation and AEA document (Dec 2007) • Bibliographic review • ISO 27891 covers procedures
• Multiply charged particles • Reference PNC cut-off • Procedure
• EMRP • Open issues
![Page 12: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/12.jpg)
Legislation / AEA PNC requirements • Full flow • τ90<5 s • Linearity: Slope 0.9-1.1, R2>0.97, all six concentrations ±10% • Counting Efficiency CE23 = 0.50±0.12, CE41 = ≥0.9
PNC check • Zero <0.2 p/cm3
• External flow check (monthly)
PNC calibration (yearly) • Comparison with electrometer (primary) or reference PNC (secondary method) • Linearity: Slope 0.9-1.1, R2>0.97, all six concentrations ±10% • Counting Efficiency CE23 = 0.50±0.12, (optional CE41 = ≥0.9)
![Page 13: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/13.jpg)
PNC issues
• Cut-off (d50%) of Reference PNC not specified • Calibration material
• For linearity any material is allowed • For d50% only emery oil and CAST • Emery oil gives higher CE
• Allowed (Non-) Linearity (20%) • k factor correction
• If applied d50% might be outside the limits • If not the d50% range is wider (0.38 – 0.68)
• Drift / degradation over time
![Page 14: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/14.jpg)
Effect of material • NaCl gave the lowest counting efficiencies • CAST and mini-CAST gave similar results with diesel exhaust particles • Emery oil gave higher counting efficiencies than CAST
0.0
0.2
0.4
0.6
0.8
1.0
0 20 40 60 80 100 120
Mobility diameter dp [nm]
Cou
ntin
g ef
ficie
ncy
Emery oilEngine - LoadSaltMini-CASTCASTEmery oil (original)
0.0
0.2
0.4
0.6
0.8
1.0
0 20 40 60 80 100 120
Mobility Diameter dp [nm]
Cou
ntin
g E
ffic
ienc
y
Emery oilCASTNaCl
Giechaskiel et al. 2009, AST, 43, 1164 Wang et al. 2010, JAS, 41, 306
![Page 15: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/15.jpg)
Effect of material: mini CAST
FVV: no effect of thermal pre-treatment of mini CAST on CE JRC: low CE (33-39%, APG mode 15nm) to normal (47%, APG mode 70 nm)
![Page 16: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/16.jpg)
Effect of material
• Emery oil Difficult to reproduce in other labs
• CAST Different counting efficiencies with different CAST settings with thermal pre-treatment. Concerns for different CAST models
Mamakos et al. 2013, AST, 47, 927
![Page 17: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/17.jpg)
(Non-) Linearity • Linear regression might be misleading. The residuals are necessary • The non-linearity can affect both VPR calibration and measurements with
different dilutions (thus concentrations)
Giechaskiel and Stilianakis 2009, MST, 20, 077003 Giechaskiel et al. 2008, MST, 19, 095401
Fletscher et al. 2009, AST, 43, 425
![Page 18: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/18.jpg)
Degradation over time • After 2.5 years of no use, no drift was observed • Some PNCs drifted • The reason is the wick (where the super-saturation is achieved) • The critical point: No light indicator identified this degrading
Giechaskiel and Bergmann 2011, JAS
![Page 19: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/19.jpg)
ISO 27891
• More detailed/strict calibration setup/procedure • Set-up / position of instruments • Repetitions • Multiply charged particles • Adds uncertainty of calibration value
• Possibility to check/calibrate <1000 p/cm3
• PNC reference dmin (almost at the plateau)
![Page 20: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/20.jpg)
EMRP
• DMA size standards below 80 nm: • The particle mobility diameter for particles below 80 nm is
calculated using the equations from ISO 15900 (e.g. slip correction) and is assumed to be correct by convention.
• Difficult to define soot-like aerosol (high variability) • “soot-likeness” is not the best criterion for a calibration
aerosols considering the intrinsic variability of real soot and tested aerosols
Aerosol Efficiency @ 23 nm Efficiency @ 41 nm
miniCAST 26.5 % - 48.5 % 77.5 % - 79.9 % graphite spark 41.4 % - 48.5 % 79.9 % - 93.3 % «real soot» 42.5 % - 56.6 % 83.5 % - 89.2 %
![Page 21: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/21.jpg)
PNC calibration material criteria • Monodispersity
Single charge Tunable size Sufficient number concentration Controlled morphology (spherical) Thermal stability …
• Calibration of the particle number concentration of a test CPC by comparison with an electrometer according to ISO/DIS 27891. SI-Traceability to units Volume, Time and Ampere. Linear interpolation for small number concentrations.
![Page 22: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/22.jpg)
Promising “primary” calibr. aerosol
• Heterogeneous nucleated silver particles
![Page 23: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/23.jpg)
From NMI to field
• The dissemination from the NMI’s to the field level will need “secondary” calibration aerosols with less stringent criteria
• The uncertainty of the particle number measurement will subsequently increase
• Not valid according to ISO: • For electrometer it should be ok • For ref PNC same material would be required
• Action: ISO to give possible traceability chain charts
from NMI to user
![Page 24: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/24.jpg)
NMIs FCE intercomparison
• Participants generally agree within 2 % in the size range 20 nm to 100 nm and number concentrations above 5000 cm-3 for singly charged synthetic particles.
• Larger deviations result at lower particle sizes and particle concentrations and soot particles.
![Page 25: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/25.jpg)
NMIs PNC calibration
• Preliminary results suggest that the agreement of participants is less good than in the FCE comparison.
• Increased uncertainties down the traceability chain from primary FCE reference CPC (ISO/DIS 27891).
![Page 26: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/26.jpg)
SCAR Soot
• Not evident that soot has higher variability (at least in one lab)
![Page 27: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/27.jpg)
Aviation (PNC) • Adhere to ISO 27891 recommendations • Use reagent grade n-butanol as working fluid • Operate under full flow operating conditions (flow splitting
inside the CPC is not allowed) • single count mode only with up to 10% coincidence correction • Linearity 0.90 ≤ slope ≤ 1.10 • Have counting efficiency of ≥50% at 10 nm and ≥90% at 15
nm electrical mobility diameter respectively, using an emery oil aerosol or equivalent
• Report in Standard conditions: The pressure should be measured with accuracy better than 2%
![Page 28: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/28.jpg)
Final open issues
• Calibration material PMP group • Aviation:The calibration aerosol shall be Emery oil, or an
aerosol that can be shown to provide an equivalent response. For example, if the efficiency curve is measured with a different aerosol, such as soot, the correlation to the Emery Oil curve must be provided as a chart that compares the counting efficiency obtained using both test aerosols
• Minimize adaptation of PNCs / past data inconsistencies • (10nm PNC in future)
• k factor correction • Mandatory to be applied (?) TSI comments • Stricter linearity differences range TSI comments
![Page 29: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/29.jpg)
VPR calibration
![Page 30: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/30.jpg)
Status VPR (September 2014)
• Legislation and AEA report (Dec 2007) • VPR Round Robin recommendations • EMRP • Bibliographic review
![Page 31: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/31.jpg)
Open (major) points VPR
• Calibration material / thermal pre-treatment • One or two PNC method, monitor PNC • Cut-off size of the calibration PNC • Neutralizers
Filte
r
Mixing Orifice or Chamber
Makeup Flow
Classifier
DMAConcentration1.47E+3 P/CC
ESC
ESC
CondensationParticle Counter
Particle Generator
excessConcentration1.47E+3 P/CC
ESC
ESC
CondensationParticle Counter
Thermal pre-treatment
PNC PNC
![Page 32: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/32.jpg)
Open (minor) issues VPR
• Pressures (and temperatures) during calibration effect on VPR (calibration PNC is corrected)
• Addition of polydisperse (validation check) • Measurement of penetration for WLTP • Stability criterion • C40 might not be the right material for volatile
removal efficiency
![Page 33: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/33.jpg)
EMRP
• Graphite spark generator by PALAS (DNP300) was thermally stable up to 400°C
![Page 34: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/34.jpg)
Mini CAST
• Thermally pre-treated miniCAST is stable inside a VPR
• Concerns for adequate concentration for low sizes
![Page 35: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/35.jpg)
Silver
• Silver particle aerosols need sintering at 400°C for thermal stability
• Upper size limited to 50 nm
![Page 36: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/36.jpg)
Aviation (VPR) • Achieve >99.9% removal of 30 nm tetracontane particles with
an inlet concentration of ≥50,000 particles/cm3 respectively. • If a CS is used then the diluent must be air (minimum oxygen
content of 10%). If a CS is not used, a heated dilution stage shall be placed upstream, which outputs a sample at a temperature of ≥ 423 K (150°C) and ≤ 623 K ±15 K (350°C), and dilutes by a factor of at least 8
• Instead of PCRFDF. Note that number measurements are NOT corrected for particle loss in the VPR (different to PMP). However, particle penetration measurement through VPR is required for sampling system transport performance, with minimum specifications of 30%, 55%, 65% & 70% at 15, 30, 50 & 100nm respectively.
![Page 37: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/37.jpg)
FVV: Tetracontane
• A PNC can respond differently to C40 depending on the generation method (with or without oxygen). Oxidized C40 has higher counting efficiency.
• Importance for calibration (C40 volatile removal efficiency) but also for the real tests (already discussed)
• FVV: Temperature, residence time must be defined
![Page 38: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/38.jpg)
Next steps
• The comments were included in the report • Extra comments were added based on calibration
experience • Clearly define open points and alternatives • Gather data • Organize a meeting to take decisions
![Page 39: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/39.jpg)
Actions (both 23nm and 10nm PMP, separately)
• Non calibration issues • PNC drift, or stabilization time effect • Pressure (and temperature) effect on VPRs and corrections
applied (for CVS minor effect) • PNC
• Argumentation k factor correction • Emery oil or CAST or possibility to ‘correct’ for the different
material • Relative differences +/-3% from slope (which could be
within 0.9-1.1) • Traceability chain chart
• VPR • C40 or other material (C40 with air eg atomized oil sulfuric
![Page 40: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/40.jpg)
![Page 41: Download PMP-33-04 JRC Calibration Summary - UNECE](https://reader030.vdocument.in/reader030/viewer/2022012500/617980dbcf142928634f2049/html5/thumbnails/41.jpg)