103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37 COMMITTEE EL-056 DR AS/NZS 3823.4.2:2014 Amd 1:2016 (Project ID: 103934) Draft for Public Comment Australian/New Zealand Standard LIABLE TO ALTERATION—DO NOT USE AS A STANDARD BEGINNING DATE FOR COMMENT: 18 October 2016 CLOSING DATE FOR COMMENT: 20 December 2016 Important: The procedure for public comment has changed – please read the instructions on the inside cover of this document . Amendment 1 to AS/NZS 3823.4.2:2014 Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air heat pumps—Testing and calculating methods for seasonal performance factors—Heating seasonal performance factor (ISO 16358-2:2013 (MOD)) COPYRIGHT

Upload: others

Post on 22-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

COMMITTEE EL-056

DR AS/NZS 3823.4.2:2014 Amd 1:2016

(Project ID: 103934)

Draft for Public Comment Australian/New Zealand Standard LIABLE TO ALTERATION—DO NOT USE AS A STANDARD

BEGINNING DATE FOR COMMENT:

18 October 2016

CLOSING DATE FOR COMMENT:

20 December 2016

Important: The procedure for public comment has changed – please read the instructions on the inside cover of this document.

Amendment 1 to AS/NZS 3823.4.2:2014 Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air heat pumps—Testing and calculating methods for seasonal performance factors—Heating seasonal performance factor (ISO 16358-2:2013 (MOD))

COPYRIGHT

Page 2: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

Draft for Public Comment Australian/New Zealand Standard

The committee responsible for the issue of this draft comprised representatives of organizations interested in the subject matter of the proposed Standard. These organizations are listed on the inside back cover.

Comments are invited on the technical content, wording and general arrangement of the draft.

The method for submission of comment on this document is to register and fill in an online form via Standards Hub Website. Instructions and examples of comment submission are available on the website. . Please use the following link—

https://hub.standards.org.au/hub/public/listOpenCommentingPublication.action

Comment must be via Hub, any emails or forms sent to us by fax or mail will not be considered by the Committee when it reviews the Public Comment received.

Please place relevant clause numbers beside each comment.

Editorial matters (i.e. spelling, punctuation, grammar etc.) will be corrected before final publication.

The coordination of the requirements of this draft with those of any related Standards is of particular importance and you are invited to point out any areas where this may be necessary.

Please provide supporting reasons and suggested wording for each comment. Where you consider that specific content is too simplistic, too complex or too detailed please provide an alternative.

If the draft is acceptable without change, an acknowledgment to this effect would be appreciated.

Once you have registered and submitted you comments via the online form, your comments are automatically submitted to the committee for review.

Normally no acknowledgment of comment is sent. All comments received via the Standards Hub Website by the due date will be reviewed and considered by the relevant drafting committee. We cannot guarantee that comments submitted in other forms will be considered along with those submitted via the Standards Hub online form. Where appropriate, changes will be incorporated before the Standard is formally approved.

If you know of other persons or organizations that may wish to comment on this draft Standard, could you please advise them of its availability. Further copies of the draft are available from the Publisher SAI Global at http://www.saiglobal.com/

SAI GLOBAL Customer Service Centre

Telephone: 13 12 42

Facsimile: 1300 65 49 49

e-mail: mailto:[email protected]

Internet: http://www.saiglobal.com/shop

Page 3: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

Draft for Public Comment

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND

Committee EL-056—Room Air Conditioners

DRAFT

Australian/New Zealand Standard

Performance of electrical appliances—Air conditioners and heat pumps

Part 4.2: Air-cooled air conditioners and air-to-air heat pumps—Testing and calculating methods for seasonal performance factors—Heating seasonal

performance factor (ISO 16358-2:2013 (MOD))

(Amendment 1 to AS/NZS 3823.4.2:2014)

Comment on the draft is invited from people and organizations concerned with this subject. It would be appreciated if those submitting comment would follow the guidelines given on the inside front cover.

Important: The procedure for public comment has changed – please read the instructions on the inside cover of this document

This document is a draft Australian/New Zealand Standard only and is liable to alteration in the light of comment received. It is not to be regarded as an Australian/New Zealand Standard until finally issued as such by Standards Australia/Standards New Zealand.

Page 4: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 1 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

AS/NZS 3823.4.2/Amdt 1/

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND

Amendment No. 1 to

AS/NZS 3823.4.2:2014 Performance of electrical appliances—Air conditioners and heat pumps

Part 4.2: Air-cooled air conditioners and air-to-air heat pumps—Testing and calculating methods for seasonal performance factors—Heating seasonal performance

factor (ISO 16358-2:2013 (MOD))

REVISED TEXT

The 2014 edition of AS/NZS 3823.4.2 is amended as follows; the amendments should be inserted in the appropriate places.

SUMMARY: This Amendment applies to the Preface, Appendix ZZ and Appendix ZA (new)

Published on . Approved for publication in New Zealand on behalf of the Standards Council of New Zealand on

Preface

At the end of the third paragraph, add the following sentence:

Appendix ZA has been added to provide information on the development of the climate files for Australia and New Zealand.

Appendix ZZ

ZZ2 Delete the text of Paragraph ZZ2 and replace with the following:

The following modifications are required for Australian/New Zealand conditions:

3.12 Delete the definition in Clause 3.12 and replace with the following:

heating full-load operation

operation with the equipment and controls configured for maximum continuous refrigeration capacity at H1, H2 or H3 conditions, the compressor setting is the same for all conditions

3.13 Delete the definition in Clause 3.13 and replace with the following: heating extended-load operation

operation of the equipment at maximum continuous refrigeration capacity at a higher compressor capacity than full-load operation at H2 or H3 conditions, where this mode is available

6.2 Third paragraph, delete the equation and replace with the following: 0 10015 C and 0 Ct t

6.3 After the third paragraph, add the following text: The calculation of Australian and New Zealand cooling and heating seasonal

performance factors is based on temperature bin distributions for three reference climate files. They are derived from the 2016 Nationwide House Energy Rating Scheme (NatHERS) climate files. These consist of a typical meteorological year (TMY) file compiled from raw Bureau of Meteorology climate data.

AMDT No. 1

AMDT No. 1

Page 5: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 2 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

Table 3 Delete Table 3 and replace with the following three tables:

TABLE 3.1

REFERENCE OUTDOOR TEMPERATURE BIN DISTRIBUTION FOR ‘HOT/HUMID’ ZONE

Bin number j

1 2 3 4 5 6 7 8 9 10 11 12 13

Outdoor temperature tj °C

10 9 8 7 6 5 4 3 2 1 0 1 2

Fractional bin hours

0 0 0 0 0 0 0 0 0 0 0 0 0

Bin hours nj n1 n2 n3 n4 n5 n6 n7 n8 n9 n10 n11 n12 n13

Reference bin hours (nj)

0 0 0 0 0 0 0 0 0 0 0 0 0

Bin number j

14 15 16 17 18 19 20 21 22 23 24 25

Total

Outdoor temperature tj °C

3 4 5 6 7 8 9 10 11 12 13 14

Fractional bin hours

0.004 0.014 0.036 0.061 0.105 0.108 0.191 0.155 0.108 0.094 0.069 0.054

Bin hours nj n14 n15 n16 n17 n18 n19 n20 n21 n22 n23 n24 n25

Reference bin hours (nj)

1 4 10 17 29 30 53 43 30 26 19 15 277

Page 6: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 3 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

TABLE 3.2

REFERENCE OUTDOOR TEMPERATURE BIN DISTRIBUTION FOR ‘MIXED’ ZONE

Bin number j

1 2 3 4 5 6 7 8 9 10 11 12 13

Outdoor temperature tj °C

10 9 8 7 6 5 4 3 2 1 0 1 2

Fractional bin hours

0 0 0 0 0 0 0.001 0.001 0.003 0.007 0.018 0.029 0.036

Bin hours nj

n1 n2 n3 n4 n5 n6 n7 n8 n9 n10 n11 n12 n13

Reference bin hours (nj)

0 0 0 0 0 0 1 1 4 9 23 37 47

Bin number j

14 15 16 17 18 19 20 21 22 23 24 25

Outdoor temperature tj °C

3 4 5 6 7 8 9 10 11 12 13 14

Fractional bin hours

0.050 0.084 0.077 0.102 0.099 0.095 0.111 0.087 0.080 0.061 0.041 0.020

Bin hours nj

n14 n15 n16 n17 n18 n19 n20 n21 n22 n23 n24 n25

Reference bin hours (nj)

64 108 99 132 128 122 143 112 103 79 53 26 1291

Page 7: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 4 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

TABLE 3.3

REFERENCE OUTDOOR TEMPERATURE BIN DISTRIBUTION FOR ‘COLD’ ZONE

Bin number j

1 2 3 4 5 6 7 8 9 10 11 12 13

Outdoor temperature tj °C

10 9 8 7 6 5 4 3 2 1 0 1 2

Fractional bin hours

0 0 0 0 0.001 0.005 0.008 0.017 0.020 0.026 0.029 0.044 0.045

Bin hours nj

n1 n2 n3 n4 n5 n6 n7 n8 n9 n10 n11 n12 n13

Reference bin hours (nj)

0 0 0 0 3 13 22 44 54 69 77 116 121

Bin number j

14 15 16 17 18 19 20 21 22 23 24 25

Total

Outdoor temperature tj °C

3 4 5 6 7 8 9 10 11 12 13 14

Fractional bin hours

0.059 0.064 0.081 0.089 0.123 0.098 0.092 0.071 0.061 0.038 0.020 0.009

Bin hours nj

n14 n15 n16 n17 n18 n19 n20 n21 n22 n23 n24 n25

Reference bin hours (nj)

156 169 216 238 327 262 245 189 163 101 52 23 2660

6.4.4 Delete Item b) 2) of Formula 11 and replace with the following: h j ful, jFullcapacityoperation fL t t

j PL j 1X t F t

j ful, jft t in Formula (11)

j ful, jfP t P t

Annex A Delete Figures A.1, A.2, A.3 and A.4 and replace with the following:

Page 8: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 5 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

OUTDOOR TEMPERATURE, °C

CA

PA

CIT

Y o

r L

OA

D,

WP

OW

ER

IN

PU

T,

W

t j

t100

P fu l(-7)

P fu l(7)

P fu l , f(2)

Φ fu l(7)

Φ fu l(-7)

Φ fu l(2)

0.82 × Φ fu l(7)

-7 0 2 5.5 7 10 to

Lh(t j)

Φ fu l(t j)

Φ fu l , f(t j)

P fu l(t j)

P fu l , f(t j)

FIGURE A.1 HEATING CAPACITY, POWER INPUT AND LOAD FOR FIXED CAPACITY UNITS

Page 9: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 6 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

OUTDOOR TEMPERATURE, °C

CA

PA

CIT

Y o

r L

OA

D,

WP

OW

ER

IN

PU

T,

W

t j

to

t100

P fu l(-7)

P fu l(7)

Pmin(7)

Pmin(-7)

P fu l , f(2)

Pmin,f(2)

Φ fu l(-7)

Φ min(-7)

Φ min(7)

Φ fu l(7)

Φ min,f(2)

Φ fu l , f(2)0.82 × Φ fu l(7)

-7 0 2 5.5 7 10

Lh(t j)

Φ fu l(t j)

Φ min(t j)Φ fu l , f(t j)

Φ min,f(t j)

P fu l(t j)

Pmin(t j)P fu l , f(t j)

Pmin,f(t j)

FIGURE A.2 HEATING CAPACITY, POWER INPUT AND LOAD FOR TWO-STAGE CAPACITY UNITS

Page 10: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 7 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

OUTDOOR TEMPERATURE, °C

CA

PA

CIT

Y o

r L

OA

D,

WP

OW

ER

IN

PU

T,

W

t j

t h t f tg td te t r

t100

tq

ta

P fu l(7)

P haf(7)

P haf(-7)

P fu l(-7)

Pmin(7)

Pmin(-7)

Pex t ,f(2)

Pex t(-7)

Φ min(-7)

Φ fu l(7)

Φ haf(7)

Φ min(7)Φ haf(-7)

Φex t ,f(2)

Φ fu l(-7)

Φex t(-7)0.82 × Φ fu l(7)

-7 0 25.5

7 10

Φ fu l(t j)

Φex t(t j)

Φ min(t j)

Φ haf(t j)

Φ min,f(t j)

Φ haf,f(t j)

Φ fu l , f(t j)

Φex t ,f(t j)

P fu l(t j)

Pex t(t j)

Pmin(t j)

P haf(t j)P fu l , f(t j)

Pex t ,f(t j)

Pmin,f(t j)

P haf,f(t j)

Lh(t j)

to

FIGURE A.3 HEATING CAPACITY, POWER INPUT AND LOAD FOR MULTI-STAGE CAPACITY UNITS

Page 11: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 8 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

OUTDOOR TEMPERATURE, °C

CA

PA

CIT

Y o

r L

OA

D,

WP

OW

ER

IN

PU

T,

WC

OE

FF

EC

IEN

T o

fP

ER

FR

OM

AN

CE

(CO

P)

t j

t h t f tg td te t rtq

ta

P fu l(7)

P haf(7)

P haf(-7)

P fu l(-7)

Pmin(7)

Pmin(-7)

Pex t ,f(2)

COP,ex t ,f(t f)

COP,haf,f(te)COP,haf(td)COP,min(tq) COP,mh(t j)

COP,mh,f(t j)COP,ht ,f(t j)COP,fe,f(t j)

COP,fu l l , f(tg)

Pex t(-7)

Φ min(-7)

Φ fu l(7)

Φ haf(7)

Φ min(7)Φ haf(-7)

Φex t ,f(2)

Φ fu l(-7)

Φex t(-7)0.82 × Φ fu l(7)

-7 0 2

5.5

7 10

Φ fu l(t j)

Φex t(t j)

Φ min(t j)

Φ haf(t j)

Φ min,f(t j)

Φ haf,f(t j)

Φ fu l , f(t j)

Φex t ,f(t j)

P fu l(t j)

Pex t(t j)

Pmin(t j)

P haf(t j)P fu l , f(t j)

Pex t ,f(t j)

Pmin,f(t j)

P haf,f(t j)

Lh(t j)

to

t100

FIGURE A.4 HEATING CAPACITY, POWER INPUT, LOAD AND COP FOR VARIABLE CAPACITY UNITS

Annex B

B.2 Insert the following sentence at the beginning of the first paragraph of B.2:

If the electric power consumption during inactive mode can be reliably determined by evaluation of control systems, this may be used as an alternative to the full physical tests of this Annex.

B.3 Delete the last paragraph of B.3 and replace with the following:

The default mode hours for the calculation of reference total heating seasonal performance factor are shown in Tables B.2.1, B.2.2 and B.2.3. The calculation of total heating seasonal performance factor may also be undertaken for other distributions of mode hours.

Page 12: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 9 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

Table B.2 Delete Table B.2 and replace with the following three tables:

TABLE B.2.1

DEFAULT HOURS BY MODE FOR THE CALCULATION OF REFERENCE TOTAL HEATING SEASONAL PERFORMANCE FACTOR FOR THE ‘HOT/HUMID’ ZONE

Unit Active mode

h

Inactive mode, Hia

h

Disconnected mode

h

Heating only unit 277 6236 2247

Reversible unit 277

(Cooling operation: 2247) 6236 0

TABLE B.2.2

DEFAULT HOURS BY MODE FOR THE CALCULATION OF REFERENCE TOTAL HEATING SEASONAL PERFORMANCE FACTOR FOR THE ‘MIXED’ ZONE

Unit Active mode

h

Inactive mode, Hia

h

Disconnected mode

h

Heating only unit 1291 6629 840

Reversible unit 1291

(Cooling operation: 840) 6629 0

TABLE B.2.3

DEFAULT HOURS BY MODE FOR THE CALCULATION OF REFERENCE TOTAL HEATING SEASONAL PERFORMANCE FACTOR FOR THE ‘COLD’ ZONE

Unit Active mode

h

Inactive mode, Hia

h

Disconnected mode

h

Heating only unit 2660 5555 545

Reversible unit 2660

(Cooling operation: 545) 5555 0

Page 13: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 10 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

Appendix ZA

Add new Appendix ZA.

APPENDIX ZA

DEVELOPMENT OF THE AUSTRALIAN/NEW ZEALAND CLIMATE FILES

(Informative)

ZA1 HOT/HUMID ZONE FILES

The ‘hot/humid’ zone (see Figure ZA1) file is based on the 2016 NatHERS TMY(A) file for Rockhampton, Queensland. Rockhampton is situated on the Tropic of Capricorn and is located geographically and meteorologically between the milder climates of the heavily populated south-east of the zone and the sparsely populated northern tropical areas.

The heating season for the hot/humid zone is considered to be from 1 June to 30 September and all hours during this period are tallied. Heating condition temperatures that occur outside these months are not considered.

To account for the likelihood of a residential user turning on their unit in response to the outdoor temperature (tj), a percentage was applied to each bin’s total, as per Table ZA1. At milder temperatures, there is a reduced proportion of hours counted. The percentage increases as the temperature drops, as colder conditions increase the likelihood of heating being used.

ZA2 MIXED ZONE FILES

The ‘mixed’ zone file (see Figure ZA1) is based on the 2016 NatHERS TMY(A) file for Richmond, New South Wales. The mixed zone covers a large population and represents areas where both very hot and very cold weather can be encountered. As heating performance at H2 is important for determining seasonal performance, it is desirable to have a representative location that has an adequate number of bin hours at lower temperatures for this performance to be demonstrated. Coastal locations tend to have milder overnight temperatures, so Richmond, which is slightly inland, allows the calculation of seasonal performance at both low and high temperatures.

The heating season for the mixed zone is considered to be from 1 May to 30 September and all hours during this period are tallied. Heating condition temperatures that occur outside these months are not considered.

To account for the likelihood of a residential user turning on their unit in response to the outdoor temperature (tj), a percentage was applied to each bin’s total, as per Table ZA1. At milder temperatures, there is a reduced proportion of hours counted. The percentage increases as the temperature drops, as colder conditions increase the likelihood of heating being used.

ZA3 COLD ZONE FILES

The ‘cold’ zone file (see Figure ZA1) is based on the TMY(A) file for Canberra in the Australian Capital Territory. In addition to a high annual heating load, Canberra experiences many bin hours within the critical frosting temperature range. Locations closer to the coast, while still having a high annual heating load, will not adequately demonstrate seasonal energy consumption that reflects H2 performance. Canberra also has a sufficient number of cooling hours to allow meaningful cooling performance to be demonstrated. This is not the case for the colder, largely unpopulated alpine and sub-alpine regions or New Zealand.

AMDT No. 1

Page 14: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 11 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

The heating season for the cold zone is considered to be 1 April to 31 October and all hours during this period are tallied. Heating condition temperatures that occur outside these months are not considered.

To account for the likelihood of a residential user turning on their unit in response to the outdoor temperature (tj), a percentage was applied to each bin’s total, as per Table ZA1. At milder temperatures, there is a reduced proportion of hours counted. The percentage increases as the temperature drops, as colder conditions increase the likelihood of heating being used.

LEGEND: White = hot/humid zone Grey = mixed zone Black = cold zone

FIGURE ZA1 VISUAL REPRESENTATION OF THE THREE CLIMATE ZONES USED FOR AUSTRALIA AND NEW ZEALAND

Page 15: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

DRAFT ONLY 12 DRAFT ONLY

103934 AS NZS 3823.4.2 2014 Amdt 1 Public Comment.doc - 11/10/2016 13:27:37

TABLE ZA1

FRACTION OF HEATING SEASON HOURS INCORPORATED INTO TEMPERATURE BIN DISTRIBUTION TABLES

Bin number j Outdoor temperature tj °C Fraction of raw hours counted

1 10 0.95

2 9 0.95

3 8 0.95

4 7 0.95

5 6 0.95

6 5 0.95

7 4 0.95

8 3 0.95

9 2 0.95

10 1 0.95

11 0 0.95

12 1 0.95

13 2 0.95

14 3 0.95

15 4 0.95

16 5 0.95

17 6 0.90

18 7 0.80

19 8 0.70

20 9 0.60

21 10 0.50

22 11 0.40

23 12 0.30

24 13 0.20

25 14 0.10

*** END OF DRAFT ***

Page 16: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

PREPARATION OF JOINT AUSTRALIAN/NEW ZEALAND STANDARDS

Joint Australian/New Zealand Standards are prepared by a consensus process involving representatives nominated by organizations in both countries drawn from all major interests associated with the subject. Australian/New Zealand Standards may be derived from existing industry Standards, from established international Standards and practices or may be developed within a Standards Australia, Standards New Zealand or joint technical committee.

During the development process, Australian/New Zealand Standards are made available in draft form at all sales offices and through affiliated overseas bodies in order that all interests concerned with the application of a proposed Standard are given the opportunity to submit views on the requirements to be included.

The following interests are represented on the committee responsible for this draft Australian/ New Zealand Standard:

Airconditioning and Refrigeration Equipment Manufacturers Association of Australia

Australian Building Codes Board

Australian Industry Group

CHOICE

Clean Energy Regulator

Consumer Electronics Association of New Zealand

Consumer Electronics Suppliers Association

CSIRO

Department of the Environment and Energy

Electrical Compliance Testing Association

Energy Safe Victoria

Institute of Refrigeration Heating and AirConditioning Engineers of New Zealand

The University of New South Wales

Page 17: Draft for Public Comment Australian/New Zealand Standard · Performance of electrical appliances—Air conditioners and heat pumps Part 4.2: Air-cooled air conditioners and air-to-air

Standards Australia

Standards Australia is an independent company, limited by guarantee, which prepares and publishes

most of the voluntary technical and commercial standards used in Australia. These standards are

developed through an open process of consultation and consensus, in which all interested parties are

invited to participate. Through a Memorandum of Understanding with the Commonwealth

government, Standards Australia is recognized as Australia’s peak national standards body.

Standards New Zealand

The first national Standards organization was created in New Zealand in 1932. The New Zealand

Standards Executive is established under the Standards and Accreditation Act 2015 and is the

national body responsible for the production of Standards.

Australian/New Zealand Standards

Under a Memorandum of Understanding between Standards Australia and Standards New Zealand,

Australian/New Zealand Standards are prepared by committees of experts from industry,

governments, consumers and other sectors. The requirements or recommendations contained

in published Standards are a consensus of the views of representative interests and also take

account of comments received from other sources. They reflect the latest scientific and industry

experience. Australian/New Zealand Standards are kept under continuous review after publication

and are updated regularly to take account of changing technology.

International Involvement

Standards Australia and Standards New Zealand are responsible for ensuring that the Australian

and New Zealand viewpoints are considered in the formulation of international Standards and that

the latest international experience is incorporated in national and Joint Standards. This role is vital