JIAXING KEXUN ELECTRON CO.,LTD
Alarm indicator system
Instruction (KX1.229.008SM)
(Version 0.2) (Total 13 pages)
Address: No.478 Xinnong Road Xiuzhou District Jiaxing Zhejiang
Tel: +0086-0573-82713489
Fax: +0086-0573-82713403
Web: http://www.kexun.cn
Email: [email protected]
KX1.229.008SM V0.2
I
Content
Foreword┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅Ⅱ
1 General┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅ 1
1.1 Function summary┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅ 1
1.2 Function feature┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅ 1
1.3 Model definition┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅ 1
2 System configuration┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅ 1
3 Function description┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅2
4 Technical parameter┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅3
4.1 Power supply┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅3
4.2 Maximum power loss┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅3
4.3 Ambient condition┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅3
4.4 Alarm signal frequency┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅3
4.5 Alarm signal loudness of wall mount alarm indicator┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅4
4.6 Alarm signal loudness of flush type alarm indicator┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅4
4.7 Identified signal┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅4
4.8 Identifying mode┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅4
5 Equipment installation┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅4
5.1 Outline dimensions┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅4
5.2 System connection┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅8
6 Notice┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅┅10
KX1.229.008SM V0.2
II
Foreword
Alarm indicator is designed according to the requirements in Part 4/ Chapter 1/Section 3
and Part 7/Chapter 2/Section 4 of CCS Rules for Classification of Steel ships 2006, IMO
Resolution A830(19)(1995) Code on alarms and indicators and GB9193 Acoustic, optical
alarm signals and identifying indications in ships; test items and test method introduce the
relevant clauses in CCS guidance notes GD01-2006 Guidelines for Type Approval Test of
Electric and Electronic Products.
This instruction is issued firstly in September 2007 and version is V0.0.
This instruction is revised firstly in June 2008 and version is V0.1.
This instruction is revised secondly in June 2010 and version is V0.2.
This revision include following:
1. Add 1.2 function feature.
2. Revise system connection diagram.
3. In the system configuration, add SGB-8, SGF-8 alarm indicator and quantity is changed
to 1~20; add alarm indicator whose model with suffix A.
4. Revise ambient temperature +5℃~+55℃ to 0℃~+55℃.
5. Update the contents of 3. Function description.
KX1.229.008SM V0.2
1
1 General
1.1 Function summary Alarm indicator could detect the signals of general emergency alarm, telegraph alarm, telephone call, machinery alarm, fire alarm, CO2 alarm, engineers’ alarm and water mist alarm, and then send out various audible and visual alarm signals. At the same time, the alarm indicator on the control console could also distinguish the type of alarm signals so that the duty crews could take necessary measures for emergency. 1.2 Function feature 1. Combined indicator column reduce the space usage and viewing range is wide. 2. Alarm display is LED instead of bulb so as to prolong the life and reduce the power loss. 3. Serial port is introduced to transmit the signal between alarm indicator and relay box, so
only four-core cable is required including the power supply. 4. Automatic switchover between main power supply and emergency power supply and also
has power failure alarm function. 5. If two power supplies are AC220V, system can be connected with up to 20 alarm indicators.
1.3 Model definition
Sort number description: K for relay box, B for alarm indicator(wall mount) and F for alarm indicator(wall mount and flush type).
2 System configuration Table 1
No. Model Name Qty. Weight Protection class Remark
1 SGK-7 Relay box 1 17Kg IP44
2 SGB-6 Alarm indicator(6 ways) 18Kg IP44
3 SGB-7 Alarm indicator(7 ways) 18Kg IP44
4 SGB-8 Alarm indicator(8 ways) 20Kg IP44
5 SGF-6G Alarm indicator(6 ways) 2Kg IP44
6 SGF-6Q Alarm indicator(6 ways)
1~10
1.3Kg IP20
Main power AC220V
Standby power DC24V
Q ty of ala rm signal
Symbol for ala rm indicator Sort number K , B, F
SG
Q: flu sh type
G : w all m ount
A for standby pow er A C22 0V N o for sta ndby p ow er D C2 4V
KX1.229.008SM V0.2
2
Table 1(continued)
No. Model Name Qty. Weight Protection class Remark
7 SGF-7G Alarm indicator(7 ways) 2Kg IP44
8 SGF-7Q Alarm indicator(7 ways) 1.3Kg IP20
9 SGF-8G Alarm indicator(8 ways) 2Kg IP44
10 SGF-8Q Alarm indicator(8 ways)
1~10
1.3Kg IP20
Main power AC220V
Standby power DC24V
11 12KFX-7 Junction box 3 2Kg IP22
12 SGK-7A Relay box 1 17Kg IP44
13 SGB-6A Alarm indicator(6 ways) 18Kg IP44
14 SGB-7A Alarm indicator(7 ways) 18Kg IP44
15 SGB-8A Alarm indicator(8 ways) 20Kg IP44
16 SGF-6AG Alarm indicator(6 ways) 2Kg IP44
17 SGF-6AQ Alarm indicator(6 ways) 1.6Kg IP20
18 SGF-7AG Alarm indicator(7 ways) 2Kg IP44
19 SGF-7AQ Alarm indicator(7 ways) 1.6Kg IP20
20 SGF-8AG Alarm indicator(8 ways) 2Kg IP44
21 SGF-8AQ Alarm indicator(8 ways)
1~20
1.6Kg IP20
Main power AC220V
Standby power AC220V
22 12KFX-7 Junction box 3 2Kg IP22
3 Function description All input terminals are normally open contacts. It will make alarm indicator work when detect any closed contact. When telephone call is detected, the light on SGB alarm indicator for telephone call will blink, the speaker will send out 800Hz intermittent alarm tone(1s on and 1s off) and the yellow rotating lamp will work. Moreover, the light on SGF alarm indicator for telephone call will also blink, the buzzer will send out 800Hz intermittent alarm tone(1s on and 1s off). When telegraph alarm is detected, the light on SGB alarm indicator for telegraph alarm will blink, the speaker will send out 800Hz intermittent alarm tone(0.5s on and 0.5s off) and the yellow rotating lamp will work. Moreover, the light on SGF alarm indicator for telegraph alarm will also blink, the buzzer will send out 800Hz intermittent alarm tone(0.5s on and 0.5s off). When machinery alarm is detected, the light on SGB alarm indicator for machinery alarm will blink, the speaker will send out 800Hz/1000Hz conversion alarm tone and the yellow rotating lamp will work. Moreover, the light on SGF alarm indicator for machinery alarm will also blink, the buzzer will send out intermittent alarm tone. When general emergency alarm is detected, the light on SGB alarm indicator for general
KX1.229.008SM V0.2
3
emergency alarm will blink, the speaker will send out 1000Hz seven-short-one-long alarm tone (short tone 1s, long tone 3s and interval 1s, interval between two periods is 3s) and the green rotating lamp will work. Moreover, the light on SGF alarm indicator for general emergency alarm will also blink, the buzzer will send out seven-short-one-long alarm tone. When CO2 alarm is detected, the light on SGB alarm indicator for CO2 alarm will blink, the speaker will send out 1000Hz continuous alarm tone and the red rotating lamp will work. Moreover, the light on SGF alarm indicator for CO2 alarm will also blink, the buzzer will send out continuous alarm tone. When fire alarm is detected, the light on SGB alarm indicator for fire alarm will blink, the speaker will send out 500~1200Hz continuous FM tone and the red rotating lamp will work. Moreover, the light on SGF alarm indicator for fire alarm will also blink, the buzzer will send out continuous FM tone. When engineers’ alarm is detected, the light on SGB alarm indicator for engineers’ alarm will blink, the speaker will send out 500~1000Hz intermittent FM tone(period intermittent 0.5s) and the yellow rotating lamp will work. Moreover, the light on SGF alarm indicator for engineers’ alarm will also blink, the buzzer will send out intermittent FM tone. When water mist alarm is detected, the light on SGB alarm indicator for water mist alarm will blink, the speaker will send out 500~1200Hz continuous FM tone and the red rotating lamp will work. Moreover, the light on SGF alarm indicator for water mist alarm will also blink, the buzzer will send out continuous FM tone.
4 Technical parameter
4.1 Power supply: AC220V±10%,DC24V %30%25
+− .
4.2 Maximum power loss: SGB alarm indicator 50W; SGF alarm indicator 10W; SGK relay box 20W.
4.3 Ambient condition: a) Ambient temperature: 0℃~+55 ℃;
b) Relative humidity: ≤92%±3%(+45℃); c) Atmospheric pressure: 86 kPa ~ 106 kPa; d) Inclination and swing; e) Vibration and impact occurred onboard; f) Humid air, salt mist and oil.
4.4 Alarm signal frequency: CO2 alarm, general emergency alarm: 1000Hz±5%. Fire alarm, water mist alarm: 500~1200Hz±5%.
Telegraph alarm, telephone call: 800Hz±5%. Machinery alarm: 800Hz/1000Hz±5%.
KX1.229.008SM V0.2
4
Engineers’ alarm: 500~1000Hz±5%.
4.5 Alarm signal loudness of SGB alarm indicator: 100~120dB.
4.6 Alarm signal loudness of SGF alarm indicator: 75~90dB. 4.7 Identified signal: general emergency alarm, telegraph alarm, telephone call, machinery
alarm, fire alarm, CO2 alarm, engineers’ alarm, water mist alarm. 4.8 Identifying mode: closed contact.
5 Equipment installation
5.1 Outline dimensions 5.1.1 SGK-7 relay box
嘉兴市科讯电子有限公司
日 期
型 号
主电源
防护等级
应急电源
继电器箱
序列号
报警
主电源 应急电源
消音
失电
Fig. 1
KX1.229.008SM V0.2
5
5.1.2 SGB-6/7/8 alarm indicator
SGB-6 alarm indicator SGB-7 alarm indicator
SGB-8 alarm indicator
Fig.2
KX1.229.008SM V0.2
6
5.1.3 SGF-6/7/8 alarm indicator
电源
警报指示器
嘉兴市科讯电子有限公司
电源Power
警报指示器ALARM INDICATOR
嘉兴市科讯电子有限公司
Type
Date
警报指示器
SGF-6 alarm indicator
电源
警报指示器
嘉兴市科讯电子有限公司
电源Power
警报指示器ALARM INDICATOR
嘉兴市科讯电子有限公司
Type
Date
警报指示器
SGF-7 alarm indicator
KX1.229.008SM V0.2
7
电源
警报指示器
嘉兴市科讯电子有限公司
电源Power
警报指示器ALARM INDICATOR
嘉兴市科讯电子有限公司
Type
Date
警报指示器
SGF-8 alarm indicator Fig. 3
5.1.4 12KFX-7 junction box
型分线箱
Fig. 4
KX1.229.008SM V0.2
8
5.2 System connection 5.2.1 SGK-7 alarm indicator system connection diagram
29
30
27
28
System connection diagram
SGK-7 RELAY BOX22
23
24
25
26
15
16
18
17
19
20
21
4
4321
4 21 3 4
2×2×1
SGF-6 Alarm indicator
SGF-7 Alarm indicator
4321
21 3 4
SGF-8 Alarm indicator
31 2
Main power failure 1 2 3
321
4321 321
21 3 4 31 2
AC220V DC24V
~ ~
IN1 IN2
+
- -
+
OUT224VOUT1
2×2×1
SGB-7 Alarm indicator
SGB-6 Alarm indicator
4321
21 3 4
SGB-8 Alarm indicator
2×2×1
SGB-6 Alarm indicator
SGB-7 Alarm indicator
4321
431 2
SGB-8 Alarm indicator
2×2×2.5
12KFX-7 JUNCTION BOX
4
4
4
11
10
12
13
31
32
8721 4 5
Machinery alarmTelegraphTelephone Fire alarm Engineers' alarm Water mist alarmCO release alarm2
Fig. 5
KX1.229.008SM V0.2
9
5.2.2 SGK-7A alarm indicator system connection diagram
2625 2827 3029
2×2×1 2×2×1
12KFX-7 JUNCTION BOX
4321
21 3 4
1 2 3 4
1 2 3 4
2×2×2.5
21 3 4
131210 11
431 2
1 2 3 4
432
2 3 4
431 2
1 2 3 4
SGF-7A Alarm indicator
SGF-6A Alarm indicator
SGF-8A Alarm indicator
201917 18 242321 221615
2×2×1
-
OUT124V
OUT2
+
54 7 8
431 2
1 2 3 4
Main power failure
32
31
IN2AC220V
~ ~~~
21
IN1AC220V
4
21 3
1 2 3 1
4 1
SGB-7A Alarm indicator
SGB-6A Alarm indicator
SGB-8A Alarm indicator
System connection diagram
SGK-7A RELAY BOX
SGB-7A Alarm indicator
SGB-6A Alarm indicator
SGB-8A Alarm indicator
TelegraphTelephone CO release alarm Fire alarm Engineers' alarm Water mist alarmMachinery alarm 2
Fig. 6
KX1.229.008SM V0.2
10
6 Notice Caution: Please prevent the latent danger of death or grievous injury.
6.1. Power supply should be connected firmly and reliably.
6.2. This main unit should be located in enclosed space. It must not be located in the places where may rain, be too humid, have a lot of dust or smoke, otherwise it may result in fire or electric shock.
6.3. If the product gives out abnormal odour or smoke, please stop operating it and switch it off at once, then contact us.
(If you continue operating, it may result in fire or electric shock)
6.4. During cleaning, please don’t splash the water over the product, otherwise it may result in fire or electric shock.
6.5. The product must not be located in the sunshine, near heat source such as heater, central heating and so on; otherwise it may result in fire.
6.6. The product must not be located or operated in the hazardous areas where flammable or explosive goods exist (except explosion-proof product)
6.7. The power supply of relevant equipments connected with main unit should be grounded reliably; otherwise it will result in bad communication. It will not only damage the equipment, but also endanger personnel safety.