international seminar - - שימור

55
International Seminar Assessment and improvement of structural safety under seismic actions of existing constructions: Reinforced Concrete Structures and Historical buildings SCE - Shamoon College of Engineering, Beer Sheva - 29 November 2015 International Conservation Center, Citta' di Roma, Old Acre - 1 December 2015 Prof. Maria Rosa Valluzzi University of Padova, Department of Cultural Heritage [email protected] Investigation methodologies and techniques: historical investigations, surveys, in-situ and laboratory tests, monitoring

Upload: others

Post on 11-Jun-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: International Seminar - - שימור

International Seminar

Assessment and improvement of structural safety under seismic actions of existing

constructions: Reinforced Concrete Structures and Historical buildings

SCE - Shamoon College of Engineering, Beer Sheva - 29 November 2015

International Conservation Center, Citta' di Roma, Old Acre - 1 December 2015

Prof. Maria Rosa Valluzzi

University of Padova, Department of Cultural Heritage

[email protected]

Investigation methodologies and techniques:

historical investigations, surveys, in-situ and laboratory tests, monitoring

Page 2: International Seminar - - שימור

Existing buildings are affected by many uncertainties concerning various aspects detectable with diagnosis investigations: - Geometry - Materials - Structural system and configuration (conceptual design) - Structural component typology - Constructive details - Effect of deterioration and damage - Influence of interventions - Interaction with soil

INVESTIGATION FOR KNOWLEDGE

Preservation of historic buildings: - In-situ low-obtrusive procedures - Combination of techniques for cross-checking

(complementarity)

Objectives: - Improve knowledge - Minimize interventions - Calibration and validation of assessment models

Page 3: International Seminar - - שימור

Iscarsah Guidelines - Recommendations for the analysis, conservation, and structural restoration of architectural heritage

This knowledge can be reached by:

• description of the structure’s geometry and construction; • definition, description and understanding of building’s historic and cultural significance; • description of the original building materials and construction techniques; • historical research covering the entire life of the structure including both changes and any

previous structural interventions; • description of the present state including identification of damage, decay and

possible progressive phenomena, using appropriate types of test; • description of the actions involved, structural behaviour and types of materials; • a survey of the site, soil conditions and environment of the building.

STRUCTURAL CODES APPROACH

Page 4: International Seminar - - שימור

The knowledge of the masonry historical building, using particular techniques of analyses and interpretation, is the basis for a reliable appraisal of the seismic safety and for the choice of an effective improvement.

Steps:

• Building identification • Functional characterisation of the building • Geometrical survey • Historical analyses of events and past interventions • Material and structural survey and conservation state • Mechanical characterization of materials • Ground and foundations • Monitoring

Different knowledge levels and confidence factors CF

Italian Standard & Guidelines – Building knowledge

STRUCTURAL CODES APPROACH

Page 5: International Seminar - - שימור

Monitoring allows to evaluate the behaviour of the structure during its life, enabling the scheduling of maintenance works, and indicating the possible necessity of strengthening or repair interventions.

Monitoring start with basic visual inspection, to evaluate

macroscopic changes in the structure (damage pattern onset, widening of existing

cracks…), up to more

sophisticated electronic controls on significant mechanical or

physical parameters.

MONITORING FOR MAINTENANCE

Page 6: International Seminar - - שימור

To evaluate the capacity of structural elements, the material properties have to be divided by the confidence factor, obtained on the basis of the gained level of knowledge: an higher knowledge level means higher mechanical properties that can be considered for the materials.

If the considered model for seismic safety assessment does not consider mechanical properties of the material, the confidence factor is used to reduce the acceleration corresponding to the particular limit state.

The confidence factor is determined as:

Geometrical survey

Material and constructive details inspection

Materials mechanical properties

Ground and foundations

Full geometrical and structural survey

FC1 = 0.05

Limited material and constructive details on site inspection

FC2 = 0.12

mechanical properties obtained from old data

FC3 = 0.12

Limited inspections on ground and foundation, absence of geological

data FC4 = 0.06

Full geometrical and structural survey, with crack and deformation

patterns FC1 = 0

Extended material and constructive details on site inspection

FC2 = 0.06

Limited on site testing on material mechanical properties

FC3 = 0.06

Limited inspections on ground and foundation, presence of geological

data FC4 = 0.03

Comprehensive material and constructive details on site inspection

FC2 = 0

Extended on site testing on material mechanical properties

FC3 = 0

Extended and comprehensive inspections on ground and

foundation FC4 = 0

Italian Guidelines – Building knowledge

KNOWLEDGE LEVELS

Page 7: International Seminar - - שימור

To carry out the structural analyses, it is necessary to gain proper knowledge by means of surveys, historical researches, in-situ and laboratory tests:

geometry, particular elements (such as chimneys, niches, etc), crack pattern & out of plumbs

BUILDING GEOMETRY

CONSTRUCTIVE DETAILS

MATERIAL PROPERTIES

connections, lintels, elements to counteract thrusts, vulnerable elements, masonry tipology

particularly aimed at the mechanical characterization of masonry, through inspections, NDT, MDT & DT

• by means of surveys

• limited in situ inspection • extended & comprehensive in situ inspection

• limited in situ testing (inspections) • extended in situ testing (MDT & NDT) • comprehensive in situ testing (DT)

Italian Guidelines – Building knowledge

KNOWLEDGE ASPECTS

Page 8: International Seminar - - שימור

1. HYPOTHESYS ON THE BUILDING EVOLUTION

2. IDENTIFICATION OF PLAN-ELEVATION CHARACTERISTICS

4. IDENTIFICATION AND CHARACTERIZATION OF CONSTRUCTION DETAILS/ELEMENTS

IDENTIFICATION OF RESISTING STRUCTURAL SCHEME, DEFINITION OF

ACTIONS AND MECHNICAL PARAMETERS

5. MASONRY TIPOLOGY

3. INTERPRETATION OF CRACK AND DEFORMATION PATTERNS

6. MATERIALS CHARACTERIZATION

INVESTIGATION PLAN

Page 9: International Seminar - - שימור

?

HISTORIC SURVEY

Page 10: International Seminar - - שימור

Geometrical survey includes: survey at each floors of all masonry elements and eventual niches, voids, chimneys, vault survey, floors, roofing, stairs, definition of loads, foundations.

GEOMETRY

Page 11: International Seminar - - שימור

Survey and drawing of crack and

deformation patterns

GEOMETRY

Page 12: International Seminar - - שימור

- quality of connections between walls;

- type and quality of connections between

horizontal diaphragms and walls;

- type and efficiency of lintels above openings;

- presence and efficiency of elements to

counteract horizontal thrusts;

- presence of structural or non structural

elements with high vulnerability;

- type and quality of masonry

CONSTRUCTION DETAILS

Page 13: International Seminar - - שימור

STRUCTURAL COMPONENTS TYPOLOGIES

Page 14: International Seminar - - שימור

Limited on-site verifications: based on visual surveys, usually through tests on the masonry that lead to superficial examination Extended and comprehensive on-site verifications: based on visual surveys, usually through tests on

the masonry that lead to both superficial and deep examination, and of the connection between orthogonal walls.

The critical analysis is carried out by means of visual inspections, by removing plaster and small masonry dismantling, in order to check both masonry texture and masonry in its thickness, considering also the connections between walls and between walls and floors.

CONSTRUCTION DETAILS

Page 15: International Seminar - - שימור

It Is possible to refer to abaci for the evaluation of the quality and bearing capacity of masonry typologies

Survey forms: frequent local masonry typologies

Heterogeneous masonry built up with poor materials, presence of voids, irregularities, multi-leaf sections, absence of connections

Out-of-plane brittle collapses

MASONRY TYPOLOGIES

Page 16: International Seminar - - שימור

Montesanto di Sellano (PG) - Politecnico di Milano

Texture with sub-horizontal courses

Irregular texture

Regular texture

MASONRY TYPOLOGIES

Page 17: International Seminar - - שימור

TWO-LEAF WALLS

Progetto esecutivo Reluis 2005-2008; Allegato 3b.1_UR06_2

MASONRY MORPHOLOGY

Page 18: International Seminar - - שימור

THREE-LEAF WALLS

Progetto esecutivo Reluis 2005-2008; Allegato 3b.1_UR06_2

MASONRY MORPHOLOGY

Page 19: International Seminar - - שימור

MASONRY QUALITY EVALUATION

Local constructive rule parameters: • mortar quality • presence of transverse connecting elements • elements shape • elements dimension • staggering vertical joints • horizontality of the courses • units strength • wedges

(University of Perugia)

MASONRY QUALITY

Page 20: International Seminar - - שימור

Local dismantling and recontruction of the inner morphology of the wall

(Binda, 2011)

CONSTRUCTION DETAILS

Page 21: International Seminar - - שימור

EXPERIMENTAL

TESTS

Qualitative tests

laboratory on-site

Quantitative tests

• Historical investigations • Survey of the crack outline • Moisture • Other NDT (sonic tests, radar, thermograph, etc)

• Geometric survey • Monitoring and control of the structure • Measurements of the local stress state (flat jacks, etc.)

Qualitative and quantitative data: geometric and mechanic parameters

Sampling

Chemical tests

Physical tests

Mechanical tests

Input parameters for the calculation models

Evaluation of the bearing capacity of the structure

(Binda, 1994)

EXPERIMENTAL TEST PROCEDURES

Page 22: International Seminar - - שימור

MATERIAL INSPECTIONS

INSPECTIONS ON STRUCTURES

STRUCTURAL HEALTH MONITORING

Medium Destructive Test (MDT)

Destructive Test (DT)

Non- Destructive Test (NDT)

Destructive Tests provide direct information on the mechanical properties of materials. Nevertheless, the main problem is the obtrusiveness of the investigation procedure.

Non-Destructive Tests are indicated as a complement to Destructive / Medium Destructive Tests. The combined use of NDT and DT / MDT and the cross-check of the results can induce more "quantitative“ significance to the NDT results, through a calibration at local level.

NDT tests extended in large areas may address MDT for the best optimization of the experimental campaign and the exploitation of the resources, to improve the knowledge of the structure.

EXPERIMENTAL TEST PROCEDURES

Page 23: International Seminar - - שימור

INNER INSPECTIONS AND TESTING ON SAMPLES

(Politecnico di Milano)

Local dismantling for direct visual inspection Sampling for lab tests

Page 24: International Seminar - - שימור

INVESTIGATIONS

ON MATERIALS

INVESTIGATIONS

ON MASONRY

MONITORING

AND CONTROL

OF THE

STRUCTURES

Minor

destructive tests

(MDT)

• direct inspections, endoscopies, core boring • single flat jacks • double flat jacks • shove test • pull-out test • dilatometer

Destructive

tests

Laboratory

On-site

• mono-axial direct compression • diagonal compression • shear-compression

Non-destructive

tests (NDT)

passive

active

• surveys and maps • pictures • displacements measurements • spontaneous phenomena (magnetometers)

• sonic and ultrasonic tests • radiography, georadar • thermographs • sclerometer • dynamic tests

INVESTIGATION METHODS FOR MASONRY BUILDINGS

Page 25: International Seminar - - שימור

Direct evaluation of mechanical properties

strength

deformability

• compression • shear

• elastic modulus • shear modulus • Poisson coefficient

UNIAXIAL COMPRESSION DIAGONAL COMPRESSION SHEAR-COMPRESSION

DESTRUCTIVE TESTS

Page 26: International Seminar - - שימור

Strength of masonry walls: compression

On-site

Lati A/B Lati R/L

W 10 W 10

W 20

(Bettio, Modena 1993)

laboratory

Mechanical properties of the original masonry and after consolidation interventions (E, n, fm) through experimental tests

DESTRUCTIVE TESTS

Page 27: International Seminar - - שימור

The compression behavior shows the differences in terms of resistances and stiffness brought from different kinds of intervention.

(Bettio, Modena 1993)

Jacketing

Injections

Original masonry

Strength of masonry walls: compression

DESTRUCTIVE TESTS

Page 28: International Seminar - - שימור

On site compression and shear

0

20

40

60

80

100

120

140

0 1 2 3 4 5

DS-D1 [mm]

H [

kN

]

Envelope

Idealized

Experiment

Ke=197.5 kNmm

Hu=110 kN

du=7.34

On site diagonal-compression

DESTRUCTIVE TESTS

Page 29: International Seminar - - שימור

Mechanical properties of the original masonry and after consolidation interventions (t0, G) with experimental tests

DESTRUCTIVE TESTS

0

50

100

150

200

0.0 0.7 1.4 2.1 2.8

R (%)

H (

kN)

Grouted

Existing

(b)

Page 30: International Seminar - - שימור

INVESTIGATIONS

ON MATERIALS

INVESTIGATIONS

ON MASONRY

MONITORING

AND CONTROL

OF THE

STRUCTURES

Minor

destructive tests

(MDT)

• direct inspections, endoscopies, core boring • single flat jacks • double flat jacks • shove test • pull-out test • dilatometer

Destructive

tests

Laboratory

On-site

• mono-axial direct compression • diagonal compression • shear-compression

Non-destructive

tests (NDT)

passive

active

• surveys and maps • pictures • displacements measurements • spontaneous phenomena (magnetometers)

• sonic and ultrasonic tests • radiography, georadar • thermographs • sclerometer • dynamic tests

MINOR DESTRUCTIVE TESTS

Page 31: International Seminar - - שימור

CORING

To understand the morphology of a masonry wall it is important a direct inspection. Sometimes it could be performed by removing few bricks or stones. Coring is commonly done with a rotary driller using a diamond cutting edge. A small camera may be inserted into the borehole allowing a detailed study of its surface and try a reconstruction of the wall section.

Drilled core and reconstruction (Binda, 2000)

Other slightly destructive tests are: - the penetration tests proposed in different ways, like probes, drillers, etc. correlate the depth of penetration to the mortar mechanical properties; - the pull-out tests can only be used on bricks and stones - the dilatometer can give deformability properties of inner cores

MINOR DESTRUCTIVE TESTS

Page 32: International Seminar - - שימור

SINGLE FLAT JACK TEST

The determination of the state of stress is based on the stress relaxation caused by a cut perpendicular to the wall surface; the stress release is determined by a partial closing of the cutting, i.e. the distance after the cutting is lower than before. A thin flat-jack is placed inside the cut and the pressure is gradually increased to obtain the distance measured before the cut.

The equilibrium relationship is the fundamental requirement for all the applications where the flat-jack are currently used (ASTM, 1991):

Sf = Kj Ka Pf

Sf = calculated stress value Kj = jack calibration constant (<1) Ka = slot/jack area constant (<1) Pf = flat-jack pressure

0.00 0.50 1.00 1.50 2.00Stress [MPa]

0

200

400

600

800

Dis

plac

emen

t [m

icro

n]

2 3 4 5

5

3

4

2

Single flat-jack test (detection of state of stress) carried out at the Monza Tower (Binda, 1998)

MINOR DESTRUCTIVE TESTS

Page 33: International Seminar - - שימור

Rilem committee MDT, 2003

Double flat-jack test (stress-strain behaviour) on West side of the Monza Tower (Binda, 1998)

DOUBLE FLAT JACK TEST

The test described can also be used to determine the deformability characteristics of a masonry. A second cut is made, parallel to the first one and a second jack is inserted, at a distance of about 40 to 50 cm from the other. The two jacks delimit a masonry sample of appreciable size to which a uni-axial compression stress can be applied.

MINOR DESTRUCTIVE TESTS

Page 34: International Seminar - - שימור

INVESTIGATIONS

ON MATERIALS

INVESTIGATIONS

ON MASONRY

MONITORING

AND CONTROL

OF THE

STRUCTURES

Minor

destructive tests

(MDT)

• direct inspections, endoscopies, core boring • single flat jacks • double flat jacks • shove test • pull-out test • dilatometer

Destructive

tests

Laboratory

On-site

• mono-axial direct compression • diagonal compression • shear-compression

Non-destructive

tests (NDT)

passive

active

• surveys and maps • pictures • displacements measurements • spontaneous phenomena (magnetometers)

• sonic and ultrasonic tests • radiography, georadar • thermographs • sclerometer • dynamic tests

NON DESTRUCTIVE TESTS

Page 35: International Seminar - - שימור

NDT can be helpful in finding hidden characteristics (internal voids and flaws and characteristics of the wall section) which cannot be known otherwise than through destructive tests.

BOREHOLE VIDEO-ENDOSCOPY

Usually integrate the coring inspection in order to detect the morphology of the wall section (or the structural component – also floors, roof, etc..), thickness, presence of voids, cracking, the effectiveness of interventions (e.g., injections), etc.

NON DESTRUCTIVE TESTS

Page 36: International Seminar - - שימור

Misure Indirette Orizzontali Misure Indirette Verticali

Misure Dirette "Trasparenza"

Punto di Misura

Accelerometro

Martello Strumentato

horizontal vertical

(m*dx,n*dy)

(0,0)

Lato

TX

-RX

2

1 2 3

1

2

3

1 2 3 4

4

3

2

111V 12V10VV9

7V 8V6VV5

V4V3V21V

Lato

TX

-RX

4

Lato TX-RX 1

Lato TX-RX 3

Totale Ventagli di Misura

Y

X

Superficial (indirect)

Side 1

Side 3

Sid

e 2

Sonic Tomography

(direct)

SONIC PULSE VELOCITY TEST

The use of sonic tests has the following aims: - to qualify masonry through the morphology of the wall section; - to detect the presence of voids and flaws; - to find crack and damage patterns; - to control the effectiveness of repair by injection technique.

NON DESTRUCTIVE TESTS

Page 37: International Seminar - - שימור

SONIC TEST: qualitative evaluation for masonry morphology and effectiveness of intervention (injections)

NON DESTRUCTIVE TESTS

(Binda, 2000)

0 20 40 60 80 100 120 140 160 180 200 220

15

45

75

105

135

165

650 m/s

700 m/s

750 m/s

800 m/s

850 m/s

900 m/s

950 m/s

1000 m/s

1050 m/s

Esterno mura Interno mura 0 20 40 60 80 100 120 140 160 180 200 220

15

45

75

105

135

165

850 m/s

900 m/s

950 m/s

1000 m/s

1050 m/s

1100 m/s

1150 m/s

1200 m/s

1250 m/s

1300 m/s

Esterno mura Interno mura

T15T3522 cm 22 cm

Sezione A-A

220 cm

88,5 cm

T36

64

0 cm

-34 cm

zoccolo in mattoni e pietra

T16

64

116 cm

34 cm 34 cm

T33

38 cm

T3430 cm

54

44

37 cm

34

24

T32

T13

38 cm

T1430 cm

54

44

37 cm

34

24

T12

256 cm

6,5 cm 14T31

146,5 cm

T11

traccia del foro sulparamento esterno

schema delle illuminazioni per la prova sonica tomografica

CINTA MURARIA DI CITTADELLA (PD)

Page 38: International Seminar - - שימור

Local and overall influence of cracks: sonic tests on a pillar of the church of SS. Crocifisso in Noto - SR (Binda, 1999)

Church of SS. Crocifisso in Noto (SR) Sonic tests on pillar D1

Sonic test grid and cracks pattern of pillar D1 Sonic velocity obtained by test SC-D1

153.54

22

.48

14

5.6

2

Pillar horizontal section

321

74 65

d37.6333.13

20

.9

b

82.78

10

1

a c

27 2628 232425 22 1.20 m

PILLAR D1 - side B

20

13

21

Sonic test SC-D1 14

7

1719 18 16 15

3

1012 11

56 4

9 8

2 1

1.35 m

1.50 m

1.65 m

PILLAR D1 - side D

1.20 m 22 2423 25 2726 28

1.50 m 118 9 10

151.35 m 1716 18

1.65 m 1 42 3

13 1412

Sonic test SC-D1

2019 21

65 7

1 2 3 4 5 6 70

100200300400500600700800900

100011001200130014001500160017001800190020002100

0100200300400500600700800900

100011001200130014001500160017001800190020002100

15 16 17 18 19 20 210

100200300400500600700800900

100011001200130014001500160017001800190020002100

22 23 24 25 26 27 280

100200300400500600700800900

100011001200130014001500160017001800190020002100

Ve

loci

tà s

on

ich

e (

m/s

ec)

vel

vel

vel

vel

8 9 10 11 12 13 14

SONIC TEST

The velocity and waveform of stress waves generated by mechanical impacts can be affected by:

- Input frequency generated by different types of instrumented hammers and transducers;

- Number of mortar joints crossed from the source to the receiver location: the velocity tends to decrease with the number of joints;

- Local and overall influence of cracks.

NON DESTRUCTIVE TESTS

Page 39: International Seminar - - שימור

12 3 4

5

2.42

1.99

0.42

0.80

12

3 4

5

COMPLEMENTARITY OF IN SITU TESTS

Flat jack tests: some results obtained with single and double flat-jack tests on the external wall of a church, of a bell tower and of a civil building in Campi Alto di Norcia (PG)

Sonic tests: representative results of the diagonal surface sonic measurements on the same walls

1

23 4

5

2.05

2.48

l v

Stato di sforzo locale 0.72 [N/mm2]

Determinazione delle caratteristiche meccaniche con martinetti piatti

CAMPI di Norcia -UIA- Chiesa S.Andrea- [CMSAJD4] - 18.7.2002

1 2 3 4

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0

Deformazioni [m/mm]

0.0

0.5

1.0

1.5

2.0

Sfo

rzi

[N/m

m2]

LVDT 5 orizzontale

media LVDT 1,2,3,4 vert.

l v

Stato di sforzo locale 0.22 [N/mm2]

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0

Deformazioni [m/mm]

0.0

0.5

1.0

1.5

2.0

Sfo

rzi

[N/m

m2]

LVDT 5 orizzontale

media LVDT 1,2,3,4 vert.

l v

Stato di sforzo locale 0.15 [N/mm2]

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0

Deformazioni [m/mm]

0.0

0.5

1.0

1.5

2.0

Sfo

rzi [

N/m

m2]

LVDT 5 orizzontale

media LVDT 1234 vert.

1 2 3 4 5 6

0

400

800

1200

1600

2000

2400

Vel

ocità

son

ica

(m/s

ec)

7 8 9 10 11 12

0

400

800

1200

1600

2000

2400

Vel

ocità

son

ica

(m/s

ec)

13 14 15 16 17 18

0

400

800

1200

1600

2000

2400

Vel

ocità

son

iche

(m

/sec

)

19 20 21 22 23 24

0

400

800

1200

1600

2000

2400

Vel

ocità

son

ica

(m/s

ec)

25 26 27 28 29 30

0

400

800

1200

1600

2000

2400

Vel

ocità

son

ica

(m/s

ec)

m/s

m/s

ecm

/sec

m/s

ec

31 32 33 34 35 36

0

400

800

1200

1600

2000

2400

1 2 3 4 5 6

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

7 8 9 10 11 12

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

13 14 15 16 17 18

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ich

e (

m/s

ec)

19 20 21 22 23 24

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

25 26 27 28 29 30

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

m/s

m/s

ec

m/s

ec

m/s

ec

31 32 33 34 35 36

0

400

800

1200

1600

2000

2400

1 2 3 4 5 6

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

7 8 9 10 11 12

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

onic

a (

m/s

ec)

13 14 15 16 17 18

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ich

e (

m/s

ec)

19 20 21 22 23 24

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica (

m/s

ec)

25 26 27 28 29 30

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

m/s

m/s

ec

m/s

ec

m/s

ec

31 32 33 34 35 36

0

400

800

1200

1600

2000

2400

Ve

loci

tà s

on

ica

(m

/se

c)

S.Andrea Church external wall

S.Andrea Church Tower

Civil Building (UI 199) south façade

Page 40: International Seminar - - שימור

GEORADAR

When applied to masonry, the applications of radar procedures can be the following: - to locate the position of large voids and inclusions of different materials, like steel, wood, etc.; - to qualify the state of conservation or damage of the walls; - to define the presence and the level of moisture; - to detect the morphology of the wall section in multiple leaf masonry. Wall section

280 cm

12

12

0

0

0

0

280 cm

280 cm

ns

ns

99

cm

0

99

cm

0

250 cm

Timber frame

40 cm

40 cm

40 cm

6 ns

6 ns

6 ns

Radargram of the wall section at the

Malpaga Castle

Local and overall influence of cracks

250 cm

Timber frame

40 cm

40 cm

40 cm

6 ns

6 ns

6 ns

Radar vs Sonic

Side 1

Side 3

Sid

e 2

NON DESTRUCTIVE TESTS

Page 41: International Seminar - - שימור

Detector of ferromagnetic

materials

Detection of metals inside materials (ferromagnetic materials) – usually used as covermeter. Eddy current principle: the induced magnetic field is dissipated when meets a conductive material

NON DESTRUCTIVE TESTS

Page 42: International Seminar - - שימור

Schimdt rebound hammer Surface hardness methods are based on the relation between the surface hardness and the compressive strength of material (concrete), selection of pointing mortars or quality control (masonry)

Class Hardness Indicative quality

0 (zero) <15 Very soft

A 15-25 Soft

B 25-35 Moderate

C 35-45 Normal

D 45-55 Hard

E 55 Very hard

NON DESTRUCTIVE TESTS

Page 43: International Seminar - - שימור

Detection of hidden steel tie rods

THERMOVISION

The thermographic analysis is based on the thermal conductivity of a material and may be passive or active. The passive application analyses the radiation of a surface during thermal cycles. If the survey is active, forced heating to the surfaces analyzed are applied

Thermovision can be very useful in diagnostic: - to identify areas under renderings and plasters, - to survey cavities, - to detect inclusions of different materials, - to detect water and heating systems, - to detect moisture presence.

NON DESTRUCTIVE TESTS

Page 44: International Seminar - - שימור

(Grinzato et al., 2002)

THERMOVISION: Investigation in the Giotto’s Chapel (Padua)

NON DESTRUCTIVE TESTS

Page 45: International Seminar - - שימור

THERMOVISION: detection of modifications due to interventions detection of structural systems

NON DESTRUCTIVE TESTS

Page 46: International Seminar - - שימור

THERMOVISION: Detection of texture and deterioration, thermal dispersion, humidity content

NON DESTRUCTIVE TESTS

Page 47: International Seminar - - שימור

Catena

Sezione peso specifico

lunghezza

libera

frequenza

propria

Tiro

mm kg/m m Hz kg

1 30 x 60 14,148 17 4,102 6879,93

2 30 x 60 14,148 17 3,906 6238,17

3 30 x 60 14,148 17 3,125 3992,94

4 30 x 60 14,148 17 4,102 6879,93

5 30 x 60 14,148 17 3,516 5054,64

T=(f l)2

Dynamic tests on ties

DYNAMIC TESTS AND MONITORING

Page 48: International Seminar - - שימור

11

22

33

66

77

55

44

22

55

66

11

22

33

66

77

55

44

22

55

66

Proprietà 1

E 1.2E+03 MPa

r 1.3E+03 kg/m3

Proprietà 2

E 3.2E+03 MPa

r 1.3E+03 kg/m3

Proprietà 3

E 1.2E+03 MPa

r 1.5E+03 kg/m3 Scena f1=3.44 Hz

Dynamic identification tests

DYNAMIC TESTS AND MONITORING

Page 49: International Seminar - - שימור

periodic

MONITORING

AND CONTROL

OF

STRUCTURES

continuous

Measure of parameters related to quasi-static effects of actions

discontinuous

static

dynamic

Time-history measurement of vibrations

Measure of Increasing parameters

Measure of variation of parameters compared to a stationary state

Crack patterns, stress states, etc.

Dynamic excitation, static loadingi, etc.

Displacement, deformations, stresses, temperature, cracks, out-of-plumb, tilting, damage, etc

accelerations, velocity, time-displacements

permanent

Measurement at regular time intervalls

Measurement at very frequent time intervals

MONITORING SYSTEMS

MONITORING AND STRUCTURAL CONTROL

Page 50: International Seminar - - שימור

Cracks

data-logger

Tilting

Piezometers Extensimeters Heavy masses monitoring

MONITORING AND STRUCTURAL CONTROL

Page 51: International Seminar - - שימור

Wind effect moniting stepped sine test FE modelling modal identification on-line data management

Data acquisition

Example of monitoring: Palazzo della Ragione (Padova, XIII-XV cen.)

direction

velocity

pressure

Web monitoring home page

Modal Analysis

www database

MONITORING AND STRUCTURAL CONTROL

Page 52: International Seminar - - שימור

CH1

CH2

N

CH3

CH4

N

ACCELERATION TRANSDUCERS

ANEMOMETER

DISPLACEMENT TRANSDUCERS

TEMPERATURE AND RH SENSORS

Example of a monitoring system for the control of the behavior: Qutb Minar – New Delhi (India)

1 2

3

4

• Positioning of sensors: 1 - acceleration transducers 2 - temperature and R.H. sensor 3 - displacement transducer 4 - wind velocity and direction transducer

• Data acquisition and analysis

0.62 Hz 1.96 Hz 3.82 Hz

MONITORING AND STRUCTURAL CONTROL

Page 53: International Seminar - - שימור

Example of monitoring: Monza Bell Tower XVI cen.)

MONITORING AND STRUCTURAL CONTROL

Page 54: International Seminar - - שימור

Monitoring of crack patterns

‘89-’97 trend

MONITORING AND STRUCTURAL CONTROL

Page 55: International Seminar - - שימור

International Seminar

Assessment and improvement of structural safety under seismic actions of existing

constructions: Reinforced Concrete Structures and Historical buildings

SCE - Shamoon College of Engineering, Beer Sheva - 29 November 2015

International Conservation Center, Citta' di Roma, Old Acre - 1 December 2015

Prof. Maria Rosa Valluzzi

University of Padova, Department of Cultural Heritage

[email protected]

Investigation methodologies and techniques:

historical investigations, surveys, in-situ and laboratory tests, monitoring

THANKS FOR YOUR ATTENTION