127 Walgreen Road, Ottawa, Ontario K0A 1L0 T (613) 8360934 F (613) 8368183 www.gradientwind.com January 12, 2016 Dave Leung Westbank 1067 West Cordova Street, Suite 501 Vancouver, BC V6C 1C7 Dear Mr. Leung: Re: Pedestrian Level Wind Mitigation Study First Baptist Church Tower Breezeways GWE File No.: 14112PLWMitigation Gradient Wind Engineering Inc. (GWE) was retained by Westbank to conduct comprehensive wind tunnel studies including pedestrian level wind study and a mitigation study for breezeways of the First Baptist Church Tower, Vancouver, BC. This report summarizes findings of mitigation studies following the main wind study which showed unacceptable winds in the breezeways on all floors of the tower. Wind comfort was addressed in this study with two models: a 1:400 scale model to consider pedestrian wind conditions at grade and over roofs of low rise buildings, and a larger 1:100 scale model to consider wind conditions in more restricted areas of the high tower roof and the breezeways on all floors. Photograph 1 illustrates the 1:400 scale model used to perform the grade level work which was reported in report dated GWE14112 PLW dated December 17, 2015. Photographs 2, 3(a) and 3(b) illustrate the model and sample sensors used to perform initial measurements on the breezeways and roof areas. Mitigation testing was performed on screen options agreed to with Bing Thom Architects. All options considered screen placement on the north side only as they were not required on the south elevation of the breezeways. The tested options included:

Upload: others

Post on 08-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

 

127 Walgreen Road, Ottawa, Ontario K0A 1L0 

T (613) 836‐0934    F (613) 836‐8183    www.gradientwind.com 

          January 12, 2016   Dave Leung Westbank 1067 West Cordova Street, Suite 501 Vancouver, BC V6C 1C7   Dear Mr. Leung: 

Re:  Pedestrian Level Wind Mitigation Study   First Baptist Church Tower ‐ Breezeways 

GWE File No.:  14‐112‐PLW‐Mitigation 

 

Gradient Wind  Engineering  Inc.  (GWE)  was  retained  by Westbank  to  conduct  comprehensive  wind 

tunnel studies  including pedestrian  level wind study and a mitigation study for breezeways of the First 

Baptist Church Tower, Vancouver, BC.   This report summarizes  findings of mitigation studies  following 

the main wind study which showed unacceptable winds in the breezeways on all floors of the tower.  

 

Wind comfort was addressed in this study with two models: a 1:400 scale model to consider pedestrian 

wind conditions at grade and over roofs of low rise buildings, and a larger 1:100 scale model to consider 

wind  conditions  in more  restricted  areas  of  the  high  tower  roof  and  the  breezeways  on  all  floors. 

Photograph 1 illustrates the 1:400 scale model used to perform the grade level work which was reported 

in report dated GWE14‐112 PLW dated December 17, 2015. Photographs 2, 3(a) and 3(b)  illustrate the 

model and sample sensors used to perform initial measurements on the breezeways and roof areas.  

 

Mitigation  testing was performed on screen options agreed  to with Bing Thom Architects. All options 

considered screen placement on the north side only as they were not required on the south elevation of 

the breezeways. The tested options included:  

Page 2: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  2 

1. Option 1:   Overlapping  solid  screen  segments on  the north elevation of breezeway balconies. 

The assembly consists of three strips slightly overlapped with four‐inch gaps between segments 

(see Photograph 4); 

2. Option 2: Two solid screens running along both balcony edges, and one story height screens in 

the middle installed on every third floor (see Photograph 5); 

3. Option 3: Perforated screen with 30% porosity enclosing the full north side of the breezeways 

(see Photograph 6); 

4. Option 4: Perforated screen with 60% porosity enclosing the full north side of the breezeways 

(see Photograph 7). 

RESULTS 

Figures 1 to 4 illustrate the original predicted wind conditions in colour‐coded form on three breezeway 

layouts which represent the repetitive pattern over the height of the tower. As shown in the figures, the 

wind comfort levels on many breezeways are predicted to be suitable for walking or standing conditions 

especially during Spring, Autumn and Winter seasons, which does not satisfy the sitting comfort levels. 

 

Results of mitigation testing are illustrated in colour‐coded form in Figures 5 through 20, summarized as 

follows: 

1. For Option  1,  illustrated  in  Figures  5  through  8, wind  comfort  levels on  all measured  sensor 

locations become suitable for sitting for year round.  

2. For  Option  2,  illustrated  in  Figure  9  through  12,  wind  comfort  become  suitable  for  sitting 

conditions for most of the  locations except for some north balcony areas on Levels 48, 50, 51, 

and 53 which are suitable for standing during Spring, Autumn and Winter.  

3. For Option 3, illustrated in Figures 13 to 16, wind comfort levels become suitable for sitting for 

all of the locations for year round except for the north balcony areas on Levels 50 and 53 which 

are suitable for standing during spring season. For Option 4, illustrated in Figures 17 to 20, wind 

comfort become sitting for most of the locations except for some areas on Levels 32, 35, 38, 48, 

50, 51, and 53 which are suitable for standing during Spring, Autumn and Winter seasons. 

SUMMARY AND RECOMMENDATIONS 

Based on the foregoing results, we offer the following conclusions and recommendations.: 

Page 3: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  3 

 

(i) All  4 mitigation  options, which  apply  screening  on  the  north  elevations  of  the  breezeways  only, 

provide adequate wind protection that significantly reduced wind speeds over the breezeways; 

(ii) The most effective screening was provided by Option 1, and least effective was Option 4; 

(iii) We would recommend that options 2 or 3 provide the best mitigation while minimizing the pressure 

differences across the breezeways from one elevation to the other; 

(iv) It is important to note that, Option 1 will likely affect the overall structural wind forces on the tower, 

due to its high blockage of the air flow across the breezeways. Therefore, if this option is selected, it 

will be necessary to repeat the structural wind  load  tests to ensure that  the structural wind  loads 

and accelerations are not increased; 

(v) Wind comfort over the high roof terraces are presented in the original pedestrian level wind study 

GWE14‐112 PLW. 

 

   

Page 4: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  4 

This conclude our wind comfort and mitigation tests for the breezeway balconies of First Baptist Tower. 

Please advise us of any questions or comments. 

 

Sincerely,  

Gradient Wind Engineering Inc.    Un Yong Jeong, PhD, P.Eng.        Daniel Cormier, MSc, EIT. Partner              Research Engineer     

Vincent Ferraro, M.Eng., P.Eng. Principal  GWE14‐112‐PLW Mitigation   

Page 5: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  5 

 PHOTOGRAPH  1:  1:400 SCALE MODEL TO PROVIDE REFERENCE WIND SPEEDS AT GRADE AND 

ROOF LEVEL 

 PHOTOGRAPH  2:  1:100 SCALE DETAILED PARTIAL MODEL OF BUILDING USED FOR 

MITIGATION TESTING. 

Page 6: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  6 

 

 PHOTOGRAPHS 3(a) AND 3(b) : 1:100 MODEL SHOWING SENSOR PLACEMENT FOR DETAILED MEASUREMENTS AND MITIGATION TESTING IN BREEZEWAYS   

 

PHOTOGRAPH 4: MITIGATION OPTION 1 ‐ NORTH ELEVATION 

Page 7: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  7 

 

PHOTOGRAPH 5: MITIGATION OPTION 2 ‐ NORTH ELEVATION 

 

PHOTOGRAPH 6: MITIGATION OPTION 3 – NORTH ELEVATION (30% POROSITY) 

Page 8: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

  

 

Westbank – Bing Thom Architects – Glotman Simpson Consulting Engineers 

First Baptist Tower, Vancouver:  Breezeway ‐ Pedestrian Wind Mitigation  8 

 

PHOTOGRAPH 7: MITIGATION OPTION 4 – NORTH ELEVATION (60% POROSITY) 

Page 9: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-6

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 1: SPRING

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

#

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

Page 10: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-7

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 2: SUMMER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 11: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-8

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 3: AUTUMN

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 12: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-9

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 4: WINTER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 13: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-10

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 5: SPRING

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 1

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 14: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-11

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 6: SUMMER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 1

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 15: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-12

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 7: AUTUMN

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 1

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 16: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-13

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 8: WINTER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 1

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 17: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-14

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 9: SPRING

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 2

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 18: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-15

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 10: SUMMER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 2

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 19: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-16

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 11: AUTUMN

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 2

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 20: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-17

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 12: WINTER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 2

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 21: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-18

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 13: SPRING

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 3

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 22: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-19

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 14: SUMMER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 3

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 23: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-20

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 15: AUTUMN

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 3

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 24: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-21

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 16: WINTER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 3

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 25: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-22

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 17: SPRING

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 4

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 26: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-23

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 18: SUMMER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 4

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 27: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-24

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 19: AUTUMN

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 4

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#

Page 28: January 12, 2016 - Vancouver · gwe14-112-plw-2015-6 description drawing no. drawn by project date scale 1:900 (approx.) january 12, 2016 b.j. figure 1: spring typical floor plans

FIRST BAPTIST CHURCH TOWER, VANCOUVER, BC

PEDESTRIAN LEVEL WIND STUDY

GWE14-112-PLW-2015-25

DESCRIPTION

DRAWING NO.

DRAWN BY

PROJECT

DATE

SCALE

1:900(APPROX.)

JANUARY 12, 2016B.J.

FIGURE 20: WINTER

TYPICAL FLOOR PLANS

PEDESTRIAN COMFORT PREDICTIONS

FOR MITIGATION OPTION 4

127 Walgreen Road

Ottawa, Ontario

(613) 836 0934

LEVELS 7, 10, 13, 16, 19, 22*, 25

LEVELS 6, 9, 12, 15, 18, 21, 24*, 27

LEVELS 8, 11, 14, 17, 20, 23, 26*, 29

LEVELS 28, 31*, 34

LEVELS 30, 33*, 36

LEVELS 37, 40*, 43

LEVELS 39, 42*, 45

LEVELS 46, 49*, 52

LEVELS 48, 51*

LEVELS 32, 35*, 38 LEVELS 41, 44*, 47 LEVELS 50, 53*

1

2

5

6

7

8

13

14

19

20

11

12

17

18

23

24

PREDICTED

COMFORT

CLASSES

SITTING

STANDING

WALKING

###

NOTES:1. SCALE IS APPROXIMATE.

2. PEDESTRIAN LEVEL WIND SENSOR LOCATION.

3. * REPRESENTS TESTED FLOOR#