l2 v5 05 sce templates g 01

20
SCE TEMPLATES PACiS Technical Training Level 2 CS&P Support Team PCL CS&P Support Team

Upload: anupam0103

Post on 18-Aug-2015

222 views

Category:

Documents


5 download

DESCRIPTION

Schneider electric relay module

TRANSCRIPT

SCE TEMPLATESPACiS Technical Training Level 2CS&P Support TeamPCL CS&P Support Team Content Template Creation Template Instantiation Template FacilitiesSchneider Electric2- CS&P SCE Templates G01 Content Template Creation Template Instantiation Template FacilitiesSchneider Electric3- CS&P SCE Templates G01 Reminder1) Reminder Template : why ?- Business oriented data modelling- Speed-up configuration process- Attributes protection- LibrariesSchneider Electric4- CS&P SCE Templates G01- Libraries Several ways- Import from 2nd database / Library- From scratch2) Template creationImport from Second DB of Libraries, Other Business1Open the 2nd File2In Template List2nd Data Base appears3Select Template 2nd DB Import Template from 2nd databaseSchneider Electric5- CS&P SCE Templates G013Select Template 2nd DB4Add Selected Template from 2nd DBTo Main Current DB5Template has been importedin current DB6Close the 2nd FileTemplate from scratch Switch into Template modeRight-click on TemplatesSelect New Create Template from scratch (1)Schneider Electric6- CS&P SCE Templates G01Template from scratch1Select theNew TemplateEmpty Create Template from scratch (2)2Choose hierarchy to which this entry point is belonging to.3Choose main object = ENTRY POINTSchneider Electric7- CS&P SCE Templates G014Through Object entry window, add this objectTemplate from scratchTemplate Entry Point = ANCHOR Create Template from scratch (3)Through Object entry window, add objects in the template (in the 3 hierarchies) to complete the modelSchneider Electric8- CS&P SCE Templates G01Template ContentOne template can be instantiated in one template (= 2ndlevel of template)Up to 2 levels Content Template Creation Template Instantiation Template FacilitiesSchneider Electric9- CS&P SCE Templates G01In Object DB using Templates Entry Window1Switch in Object Mode2Select the Father Instantiate Template (1)Schneider Electric10- CS&P SCE Templates G01LIST of Template candidates =>to beinstantiated=>For this selected Fatheris refreshed3Select the template4Click AddCheck Instantiated Template pictorial representationICON Template ANCHORName of instance+ name of template Instantiate Template (2)Schneider Electric11- CS&P SCE Templates G01Temporary Graphic, Scs, SiteSub-part of the template need to be MOVED to appropriate Father (Next Slide)ICON Template Sub-PartAttached template Moving attached template Part Move or Cut/Paste- one by one- several via Contents of1Multi click with Shift/Ctrl key to select Instantiate Template (3)Schneider Electric12- CS&P SCE Templates G01key to select several parts2Cut3Select Father for 2nd part (Graphic)4PasteElectric PartSystem PartGraphic PartOne Template may haveTemplate is Defined byANCHORposition name in Template List Template : ResumeSchneider Electric13- CS&P SCE Templates G01Temporary Electric PartTemporary System PartTemporary Graphic PartTemplate instance in Object DBANCHOR instanceSub part of templateDirectly Placed To MoveView Instances of one Template in Object Mode1Right Click on template2Popup all instancesREM: Reach Button when Check a Template instance (1) Schneider Electric14- CS&P SCE Templates G01REM: Reach Button when instance selected3Selecting the ANCHOR objectView Instance of one Template part in Object ModeInstance of Sub part of template1View template content Check a Template instance (2) Schneider Electric15- CS&P SCE Templates G01Gives all template instance components, include ANCHOR, and template father Content Template Creation Template Instantiation Template FacilitiesSchneider Electric16- CS&P SCE Templates G01Attributes ProtectionBy default, attributes are protected => No possibility to change in Object Mode DOF : Degree Of FreedomSchneider Electric17- CS&P SCE Templates G01To allow attributes modification => Define DOF in Template ModeAppears in blueCommon value in DOF attributesExample :Graphical template for switching device representation=> a lot of objects have to take the same colour => voltage level colour=> Common value in DOF => Parameter Parameters (1)2AtANCHOR level => Parameter tab1Template ModeSchneider Electric18- CS&P SCE Templates G01Parameter tab3Create a Parameter : right click,NewCommon value in DOF attributes Parameters (2)DOF attribute : 1Associate ParameterAssociate a DOF attribute to a parameter 2Choose ParameterSchneider Electric19- CS&P SCE Templates G01Common value in DOF attributes Parameters (3)1Right-Click on Parameter : 2View linked attributesView all DOF attributes associated to a parameter Schneider Electric20- CS&P SCE Templates G01Linked attributes