Leading Solution
LS Total Solution for Railway
-
1PowerCatenary SystemPower Transmission & Distribution FacilitySubstation Facility Power Incomming
-
Catenary SystemTrolley Wires 1Messenger / Dropper Wires 2Conductor Rail 3Overhead Feeder Cable 422.9kV CN/CV-W,22.9kV FR-CN/CO-W 636/66 kV with Aluminum Sheath 2036/66 kV with Lead Sheath 21F-GV 15
Power Transmission & Distribution Facility22.9kV CN/CV-W,22.9kV FR-CN/CO-W 6AAC,AAAC 128.7/15kV MV Power Cable 2412/20kV, 18/30kV MV Power Cable 220.6/1kV F-FR-8 100.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB 16450/750V HIV 146/10kV F-CV 70.6/1kV F-CV 8Outdoor Weather Proof PVC Insulated Wire 13MV Cable Joints & Terminations 26F-GV 15
Substation Facility22.9kV CN/CV-W,22.9kV FR-CN/CO-W 636/66 kV with Aluminum Sheath 2036/66 kV with Lead Sheath 210.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB 160.6/1kV F-FR-8 106/10kV F-CV 70.6/1kV F-CV 8EHV Cable Joints & Terminations 25LV Cable Joints 27F-GV 15
Power Incomming 154kV HV Power Cable 18132kV HV Power Cable 1922.9kV CN/CV-W,22.9kV FR-CN/CO-W 6Outdoor Weather Proof PVC Insulated Wire 13EHV Cable Joints & Terminations 25MV Cable Joints & Terminations 26
Power
-
3Catenary System
(PAGE : 1, 2, 3, 4, 6, 15, 20, 21)
Substation Facility(PAGE : 6, 7, 8, 10, 15, 16, 20, 21, 25, 27)
Ballast Screen Mat(PAGE : Others-36)
Ballast Mat(PAGE : Others-36)
Power Transmission & Distribution Facility(PAGE : 6, 7, 8, 10, 12, 13, 14, 15, 16, 22, 24, 26)
Power Incomming(PAGE : 6, 9, 13, 18, 25, 26)
-
3DEmergency Utility(PAGE : Others-33, 34)
Ventilation System(PAGE : Others-32, 30)
-
Application BusinessThe Leading Solution Provider, LS Cable introduced a new maketing concept, which is providingCollected items applicable to an industry as a package instead of separately providing a single item.This LS Cable s business solutions are applicable to following industries : Wind Power Generation,Railway & Rolling stock, Airport, Power Transmission & distribution, Marine & Offshore, and Automotive. The Application Business manages various departments and their products to satisfy our customers pecific needsand convenience.
-
Technical Data
RailsolTM_Xcel Trolley Wires
RailsolTM_Xcel Power Trolley Wires1
Pure Min. Breaking Load kN 29.1 36.4 37.4 41.9 52.4
High Elongation after Fracture 3~8 3~8 3~8 3~8 3~8
Strength Electrical Conductivity % IACS 97 97 97 97 97
Copper Electrical Resistance /km 0.229 0.183 0.171 0.153 0.122
t
x10-3/K 3.81 3.81 3.81 3.81 3.81
x10-5/K 1.7 1.7 1.7 1.7 1.7
Density g/cm3 8.89 8.89 8.89 8.89 8.89
Copper- Min. Breaking Load kN 35.7 43.7 45.7 50.1 61.1
Magnesium Elongation after Fracture 3~10 3~10 3~10 3~10 3~10
Alloy Electrical Conductivity % IACS 77 77 77 77 77
(CuMg0.2) Electrical Resistance /km 0.289 0.231 0.216 0.192 0.154
x10-3/K 1.85 1.85 1.85 1.85 1.85
" x10-5/K 1.7 1.7 1.7 1.7 1.7
Density g/cm3 8.89 8.89 8.89 8.89 8.89
Copper- Min. Breaking Load kN 40.4 49.5 51.9 57 68.4
Magnesium Elongation after Fracture 3~10 3~10 3~10 3~10 3~10
Alloy Electrical Conductivity % IACS 62 62 62 62 62
(CuMg0.5) Electrical Resistance /km 0.385 0.286 0.268 0.239 0.191
x10-3/K 1.85 1.85 1.85 1.85 1.85
" x10-5/K 1.7 1.7 1.7 1.7 1.7
Density g/cm3 8.89 8.89 8.89 8.89 8.89
Copper- Min. Breaking Load kN 35.7 43.7 44.6 48.9 61.1
Tin Elongation after Fracture 2~8 2~8 2~8 2~8 2~8
Alloy Electrical Conductivity % IACS 72 72 72 72 72
(CuSn0.2) Electrical Resistance /km 0.309 0.247 0.231 0.206 0.165
x10-3/K 3.65 3.65 3.65 3.65 3.65
"Linear Coefficient of
Thermal Expansion" x10-5/K 1.7 1.7 1.7 1.7 1.7
Density g/cm3 8.92 8.92 8.92 8.92 8.92
Material Technical Data UnitNominal Cross Section(mm2)
80 100 107 120 150
PureHighStrengthCopper
Copper-MagnesiumAlloy(CuMg0.2)
Copper-MagnesiumAlloy(CuMg0.5)
Copper-TinAlloy(CuSn0.2)
Temperature Coefficient of Electrical Resistance
10-3/K 3.81 3.81 3.81 3.81 3.81
10-3/K 1.85 1.85 1.85 1.85 1.85
10-5/K 1.7 1.7 1.7 1.7 1.7
10-3/K 1.85 1.85 1.85 1.85 1.85
10-5/K 1.7 1.7 1.7 1.7 1.7
10-3/K 3.65 3.65 3.65 3.65 3.65
10-5/K 1.7 1.7 1.7 1.7 1.7
Linear Coefficient of Thermal Expansion
Temperature Coefficient of Electrical Resistance
Linear Coefficient of Thermal Expansion
Temperature Coefficient of Electrical Resistance
Linear Coefficient of Thermal Expansion
Temperature Coefficient of Electrical Resistance
Linear Coefficient of Thermal Expansion
Circular Type Ladder Type Flat Bottom Type
Other dimensions available on enquiry
10-5/K 1.7 1.7 1.7 1.7 1.7
ApplicationCopper and copper alloy grooved contact wire
Design StandardEN 50149
-
RailsolTM_Xcel Power
RailsolTM_Xcel PowerMessenger / Dropper Wires 2
ApplicationCatenary wire (messenger / dropper wire)
Design StandardDIN 48201 part1 and part2
Technical Data
RailsolTM_Xcel Messenger / Dropper Wires
35 34.36 7 2.50 7.5 310 13.77 200
70 65.81 19 2.10 10.5 596 26.38 310
95 93.27 19 2.50 12.5 845 37.39 380
120 116.99 19 2.80 14.0 1060 48.90 440
185 181.62 37 2.50 17.5 1649 72.81 585
35 34.36 7 2.50 7.5 310 20.17 160
70 65.81 19 2.10 10.5 596 38.64 245
95 93.27 19 2.50 12.5 845 54.76 305
120 116.99 19 2.80 14.0 1060 67.57 350
185 181.62 37 2.50 17.5 1649 106.63 465
Nominal Calculated Number Diameter Calculated Continuous
Material Cross Cross of Weight Breaking Current-CarryingSection Section Wires Wire Conductor Load Capacity(mm2) (mm2) (mm) (mm) (kg/km) (kN) (A)
PureHighStrengthCopper
Copper-MagnesiumAlloy
-
RailsolTM_Xcel Power Conductor Rail3
Application3rd rail power feeding for LRT, MGLEV
Design StandardCustomer design
Description
RailsolTM_Xcel Conductor Rail
Alloy Si Fe Cu Mn Mg Cr Zn TiOthers
AlNumber Each Total
A6063 0.20 ~ 0.60 0.35 0.10 0.10 0.45 ~ 0.90 0.10 0.10 0.10 0.50 0.15 Leftover
Item Material Dimension Remark
Al T-Bar A6063-T5 1471mm2 12,000
Hex Bolt Set STS 304 M8 30
Contact Surface A6063-T5 -
Mechanical Properties
Al-AlloyTensile Strength Yield Strength Elongation
(N / mm2) (N / mm2) (%)
A6063-T5 157 108 8
Electrical Properties
Modulus of Modulus of ThermalTemperature
Electrical Specific Mass Longitudinal Lateral Expansion
Thermal CoefficientConductivity
(20 , g/cm2) Elasticity Elasticity CoefficientConductivity of Electrical
(20 , IACS )(kN / mm2) (kN / mm2) ( 10-6 / )
(25 , kW/m ) Resistance( 10-3 / )
51 2.7 70.6 26.2 23.4 0.21 4.2
Num. Item Dimension Material Quantity
1 Al-Conductor 12 m A6063-T5 1
2 Hex Bolt Set M8 30 STS 304 47
3 Washer M8 A6063-T5 94
4 Spring Washer M8 STS 304 47
5 Hex Nut M8 STS 304 47
Other dimensions available on enquiry
Stainless Steel
Aluminum Conductor
-
RailsolTM_Xcel Power
RailsolTM_Xcel PowerOverhead feeder cable 4
ApplicationNegative feeder cable for 25kV overhead power feeding line
Design StandardKRS PW 0009, KS C 3102, 3002, 3104, 3004
Conductor1) For hard-drawn wire, use electrical & hard-drawn copper wires prescribed in KS C 3102.2) Composition use electrical & hard-drawn copper wire or wire similar to it prescribed in KSC 3102. The outest layer pitch should be 20
times less than outer diameter wire should be twisted with S-direction.
Insulation1) Insulated with outdoor black crosslinked polyethylene concentrically on conductor with no harmful void and defect. The thickness of insu-
lation shall be the average value resulted by measuring several points of same nominal section(6 points with equal interval). The valueshall be over 90% of value in the Table 1 and the minimum over 80% of it. Semi-conductive tape or extruded semi-conductive layer con-tacts with the conductor and the thickness related to that is included in that of insulation.
2) Insulation color is black.
PerformanceTable 2
ConstructionConductor KS C 3102, hard-drawn copperConstruction Stranding pitch of last outer layer should be less than 20 times of diameter and last
outer layer should be stranded in S direction.
Insulation Cross-linked polyethylene
RailsolTM_Xcel Overhead Feeder Cable
200 37/2.6 18.2 4.0 26.2 0.0951 30 2,040 1,500
Cross Conductor InsulationOverall Diameter
Max. ConductorTest Voltage Weight
Min. InsulationSection Construction Diameter Thickness Resistance Resistance(mm2) (No / mm) (mm) (mm) (mm) ( / m) (kV) (kg / km) ( .km)
Other dimensions available on enquiry
Conductor Resistance Below the value of Table 1
Insulation Resistance Over the value of Table 1
Tracking Resistance No current more than 500mA on sample surface even in 101 spray times or No combustion
Over 1.0kgf/mm2
Over 350%
Over 80% of the value before aging
Over 90% of the value before aging
Heat Distortion Resistance Below 40% of thickness loss
Local Heat Test No crack or defect
Classification Performance
Normal Temperature
Aging Temperature
Tensile Strength
Elongation
Tensile Strength
Elongation
Insulation
Table 1
-
ApplicationType KIV is suitable for wiring on panel boards, switchboards and control apparatus at max conductortemperature at 70°C
Design StandardIEC 60227-3
450 / 750V KIV
RailsolTM_Xcel 450 / 750V KIV
Conductor Flexible stranded annealed copper
Insulation Abrasion-and moisture-resistant PVC
RailsolTM_Xcel Power 450 / 750V KIV5
1.5 1.6 0.7 2.8 3.4 13.3 13.7 0.010 30
2.5 2.1 0.8 3.4 4.1 7.98 8.21 0.009 40
4 2.6 0.8 3.9 4.8 4.95 5.09 0.007 50
6 3.6 0.8 4.4 5.3 3.30 3.39 0.006 80
10 4.8 1.0 5.7 6.8 1.91 1.95 0.0056 130
16 6.0 1.0 6.7 8.1 1.21 1.24 0.0046 180
25 7.4 1.2 8.4 10.2 0.780 0.795 0.0044 280
35 8.7 1.2 9.7 11.7 0.554 0.565 0.0038 370
50 10.4 1.4 11.5 13.9 0.386 0.393 0.0037 500
70 12.5 1.4 13.2 16.0 0.272 0.277 0.0032 700
95 14.5 1.6 15.1 18.2 0.206 0.210 0.0032 970
120 16.2 1.6 16.7 20.2 0.161 0.164 0.0029 1,200
150 18.2 1.8 18.6 22.5 0.129 0.132 0.0029 1,490
185 20.2 2.0 20.6 24.9 0.106 0.108 0.0029 1,850
240 23.3 2.2 23.5 28.4 0.0801 0.0817 0.0028 2,440
Construction
Conductor Approx. Overall Diameter
NominalCross Section
(mm2)
InsulationThickness
(mm)
InsulationResistance
(70 )(M . km)
Approx. Weight
( kg / km)
OuterDiameter
(mm)
Minimum
(mm)
Maximum
(mm)
Conductor Resistance(20 )
Non Plated
( / km)
Plated
( / km)
Other dimensions available on enquiry
-
38 7.3 34 0.481 52 1050
60 9.3 36 0.305 52 1760
100 12.0 40 0.183 52 2430
150 14.7 43 0.122 52 3150
200 17.0 45 0.0915 52 3980
250 19.0 48 0.0739 52 4700
325 21.7 51 0.0568 52 5750
400 24.1 54 0.0462 52 6850
500 26.9 57 0.0369 52 8240
600 29.5 4.0 61 0.0308 52 10050
RailsolTM_Xcel 22.9kV CN / CV-W, 22.9kV FR-CN / CO-W
Construction
Constructional Data (Nominal Values)
Conductor Circular compacted stranded filled with water blocking material plain annealed copper
Insulation 90 , Extruded cross-linked polyethylene with semi-conductive inner and outer screen
Neutral Conductor Annealed copper wires with water-blocking tapes
Sheath Black PVC / Black halogen free flame retardant polyolefin
KEPCO 60mm2, 200mm2, 325mm2, 600mm2
Other dimensions available on enquiry
3.06.6
Compacted
Circular
(Waterproof)
ApplicationPower cable used for industrial and commercial multiple grounding power and distribution circuits
Design StandardESB or LS
Certification
38 0.614 0.188 0.642
60 0.390 0.174 0.472
100 0.234 0.162 0.285
150 0.157 0.152 0.219
200 0.119 0.147 0.189
250 0.0963 0.141 0.171
325 0.0753 0.136 0.155
400 0.0624 0.132 0.146
500 0.0515 0.128 0.138
600 0.0444 0.127 0.135
Electric Constant (Reference)
Cross Section AC Conductor Resistance(R) Reactance(X) Impedance(Z)(mm2) ( / km) ( / km) ( / km)
RailsolTM_Xcel Power
RailsolTM_Xcel Power22.9kV CN / CV-W, 22.9kV FR-CN / CO-W 6
Conductor Insulation Sheath Apporx. Conductor Test Approx.Nominal Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
-
RailsolTM_Xcel Power 6/10kV F-CV7
RailsolTM_ Xcel 6/10kV F-CV
ConstructionConductor Compacted or circular stranded annealed copper class 2Insulation 90 Crosslinked polyethylene(XLPE) with semi-conducting inner & outer screenShield The semi-conducting tape and copper tape shield is applied helically over the each coreAssembly Multi-cores of cable shall be assembled to form a circular cableSheath Black Flame retardant PVC(FR-PVC)
Core Identification1 core XLPE natural color3 cores black, white, red
ApplicationPower cable used for residential and commercial buildings and industrial distribution circuits
Design StandardIEC 60502-2
16 4.7 1.5 20 1.15 46025 5.9 21 0.727 57035 6.9 22 0.524 70050 8.1 23 0.387 84070 9.8 25 0.268 110095 11.4 27 0.193 1380120 12.9 3.4 28 0.153 21 1660150 ø¯«¸æ–√‡ø¨º± 14.4 30 0.124 1950185 15.9 1.9 32 0.0991 2360240 18.3 35 0.0754 3010300 20.5 37 0.0601 3650400 23.2 40 0.0470 4520500 26.4 43 0.0366 5650630 30.2 2.3 48 0.0283 7230
6/10kV F-CV (Single Core)
21
1.5
1.6
1.7
1.8
2.0
2.1
3.4Compacted
Circular
16 4.7 2.1 39 1.15 136025 5.9 2.2 41 0.727 176035 6.9 2.3 43 0.524 214050 8.1 2.4 46 0.387 262070 9.8 2.5 50 0.268 340095 ø¯«¸æ–√‡ø¨º± 11.4 3.4 2.6 53 0.193 21 4350120 12.9 2.7 57 0.153 5200150 14.4 2.8 60 0.124 6180185 15.9 2.9 64 0.0991 7450240 18.3 3.1 69 0.0754 9430300 20.5 3.3 74 0.0601 11530
6/10kV F-CV (3 Core)
213.4Compacted
Circular
Conductor Insulation Sheath Apporx. Conductor Test Approx.Nominal Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Conductor Insulation Sheath Apporx. Conductor Test Approx.Nominal Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Other dimensions available on enquiry
-
RailsolTM_Xcel Power
RailsolTM_Xcel Power0.6/1kV F-CV 8
ApplicationType flame-retardant cable is used for power and lighting circuits in tray, undergroundduct and open air in accordance with technical standard for electrical equipments
Design StandardIEC 60502-1
Flammability Vertical tray flame test (VTFT) to IEC 60332-3-24 cat.C
RailsolTM_Xcel 0.6/1kV F-CV
1.5 7/0.53 1.59 0.7 1.4 6.3 12.1 3.5 502.5 7/0.67 2.01 0.7 1.4 6.7 7.41 3.5 704 7/0.85 2.55 0.7 1.4 7.2 4.61 3.5 906 7/1.04 3.12 0.7 1.4 7.8 3.08 3.5 11010 7/1.35 4.05 0.7 1.4 9.4 1.83 3.5 17016 4.7 0.7 1.4 10.0 1.15 3.5 21025 5.9 0.9 1.4 12.0 0.727 3.5 31035 6.9 0.9 1.4 13.0 0.524 3.5 40050 8.1 1.0 1.4 14.5 0.387 3.5 52070 9.8 1.1 1.4 16.0 0.268 3.5 72095 11.4 1.1 1.5 18.5 0.193 3.5 970120 12.9 1.2 1.5 20 0.153 3.5 1,210150 14.4 1.4 1.6 22 0.124 3.5 1,490185 15.9 1.6 1.6 24 0.0991 3.5 1,840240 18.3 1.7 1.7 27 0.0754 3.5 2,400300 20.5 1.8 1.8 30 0.0601 3.5 2,980400 23.2 2.0 1.9 34 0.0470 3.5 3,800500 26.4 2.2 2.0 37 0.0366 3.5 4,850630 30.2 2.4 2.2 42 0.0283 3.5 6,240
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (Single Core)
InsulationThickness
Approx. Overall Diameter
(mm)(mm)
Core Identification
ConstructionConductor Compacted or circular stranded annealed copper class 2Insulation 90 Cross-linked polyethylene(XLPE)Assembly Multi-cores of cable shall be assembled to form a circular cableSheath Black flame retardant PVC(FR-PVC)
Compacted Circular / Other dimensions available on enquiry
-
RailsolTM_Xcel Power 0.6/1kV F-CV9
1.5 7/0.53 1.59 0.7 1.8 11.0 12.1 3.5 1202.5 7/0.67 2.01 0.7 1.8 12.0 7.41 3.5 1504 7/0.85 2.55 0.7 1.8 13.0 4.61 3.5 1906 7/1.04 3.12 0.7 1.8 14.0 3.08 3.5 24010 7/1.35 4.05 0.7 1.8 17.0 1.83 3.5 33016 4.7 0.7 1.8 18.5 1.15 3.5 45025 5.9 0.9 1.8 22 0.727 3.5 66035 6.9 0.9 1.8 24 0.524 3.5 88050 8.1 1.0 1.8 27 0.387 3.5 1,15070 9.8 1.1 1.8 31 0.268 3.5 1,61095 11.4 1.1 1.9 35 0.193 3.5 2,170120 12.9 1.2 2.0 38 0.153 3.5 2,670150 14.4 1.4 2.2 43 0.124 3.5 3,310185 15.9 1.6 2.3 47 0.0991 3.5 4,110240 18.3 1.7 2.5 53 0.0754 3.5 5,340300 20.5 1.8 2.6 58 0.0601 3.5 6,630
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (2 Core)
InsulationThickness
Approx.Overall Diameter
(mm)(mm)
1.5 7/0.53 1.59 0.7 1.8 11.5 12.1 3.5 150
2.5 7/0.67 2.01 0.7 1.8 12.5 7.41 3.5 180
4 7/0.85 2.55 0.7 1.8 13.5 4.61 3.5 240
6 7/1.04 3.12 0.7 1.8 14.5 3.08 3.5 310
10 7/1.35 4.05 0.7 1.8 18.0 1.83 3.5 450
16 4.7 0.7 1.8 19.5 1.15 3.5 610
25 5.9 0.9 1.8 23 0.727 3.5 900
35 6.9 0.9 1.8 25 0.524 3.5 1,210
50 8.1 1.0 1.8 29 0.387 3.5 1,560
70 9.8 1.1 1.9 33 0.268 3.5 2,200
95 11.4 1.1 2.0 37 0.193 3.5 2,970
120 12.9 1.2 2.1 41 0.153 3.5 3,790
150 14.4 1.4 2.3 46 0.124 3.5 4,670
185 15.9 1.6 2.4 50 0.0991 3.5 5,830
240 18.3 1.7 2.6 57 0.0754 3.5 7,580
300 20.5 1.8 2.7 62 0.0601 3.5 9,400
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (3 Core)
InsulationThickness
Approx.Overall Diameter
(mm)(mm)
1.5 7/0.53 1.59 0.7 1.8 12.5 12.1 3.5 170
2.5 7/0.67 2.01 0.7 1.8 13.5 7.41 3.5 220
4 7/0.85 2.55 0.7 1.8 14.5 4.61 3.5 290
6 7/1.04 3.12 0.7 1.8 16.0 3.08 3.5 380
10 7/1.35 4.05 0.7 1.8 20 1.83 3.5 570
16 4.7 0.7 1.8 22 1.15 3.5 790
25 5.9 0.9 1.8 26 0.727 3.5 1,180
35 6.9 0.9 1.8 28 0.524 3.5 1,550
50 8.1 1.0 1.9 32 0.387 3.5 2,060
70 9.8 1.1 2.0 36 0.268 3.5 2,930
95 11.4 1.1 2.1 42 0.193 3.5 3,970
120 12.9 1.2 2.3 46 0.153 3.5 4,980
150 14.4 1.4 2.4 51 0.124 3.5 6,130
185 15.9 1.6 2.6 56 0.0991 3.5 7,660
240 18.3 1.7 2.8 63 0.0754 3.5 9,960
300 20.5 1.8 3.0 70 0.0601 3.5 12,380
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (4 Core)
InsulationThickness
Approx.Overall Diameter
(mm)(mm)
Compacted Circular / Other dimensions available on enquiry
-
RailsolTM_Xcel Power0.6/1kV F-FR-8 10
RailsolTM_Xcel Power
RailsolTM_Xcel 0.6/1kV F-FR-8
ConstructionConductor Compacted or circular stranded annealed copper class2Fire-proof Layer Mica tapeInsulation Cross-linked polyethylene(XLPE)Assembly Multi-Cores of cable shall be assembled to form a circular cableSheath Black flame retardant PVC(FR-PVC)
Core identification1 core XLPE natural color2 cores Black, white 3 cores Black, white, red4 cores Black, white, red, green
ApplicationF-FR-8 used for residential and commercial buildings and industrial fire proof distribution circuits
Design StandardIEC 60502-1
1.5 7 / 0.53 1.59 8.5 12.1 60
2.5 7 / 0.67 2.01 9.0 7.41 80
4 7 / 0.85 2.55 0.7 9.5 4.61 100
6 7 / 1.04 3.12 10.0 3.08 120
10 7 / 1.35 4.05 1.4 11.0 1.83 180
16 4.7 12.0 1.15 220
25 5.9 0.9 13.5 0.727 320
35 6.9 15.0 0.524 430
50 8.1 1.0 16.5 0.387 540
70 9.8 1.1 1.5 18.5 0.268 3.5 740
95 11.4 20.5 0.193 990
120 ø¯«¸æ–√‡ø¨º± 12.9 1.2 1.6 22.5 0.153 1230
150 14.4 1.4 1.7 25.0 0.124 1530
185 15.9 1.6 27.0 0.0991 1890
240 18.3 1.7 1.8 30.0 0.0754 2450
300 20.5 1.8 1.9 33.0 0.0601 3040
400 23.2 2.0 2.0 36.5 0.0470 3860
500 26.4 2.2 2.1 41.0 0.0366 4920
630 30.2 2.4 2.3 46.0 0.0283 6320
0.6/1kV F-FR-8 (Single Core)
3.5
1.7
1.5
1.4
0.7
0.9
1.1
Compacted
Circular
Conductor Insulation Sheath Approx. D.C Conductor Test Approx.Nominal Cross Section Construction Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Other dimensions available on enquiry
-
RailsolTM_Xcel Power 0.6/1kV F-FR-811
Other dimensions available on enquiry
1.5 7 / 0.53 1.59 14.0 12.1 1302.5 7 / 0.67 2.01 15.0 7.41 1704 7 / 0.85 2.55 0.7 16.0 4.61 2106 7 / 1.04 3.12 17.5 3.08 26010 7 / 1.35 4.05 1.8 19.5 1.83 35016 4.7 21.0 1.15 47025 5.9 0.9 24.5 0.727 68035 6.9 26.5 0.524 3.5 91050 8.1 1.0 30.0 0.387 118070 9.8 1.1 1.9 34.5 0.268 164095 ø¯«¸æ–√‡ø¨º± 11.4 1.1 2.0 38.0 0.193 2210120 12.9 1.2 2.2 42.0 0.153 2710150 14.4 1.4 2.3 46.5 0.124 3390185 15.9 1.6 2.4 51.0 0.0991 4200240 18.3 1.7 2.6 57.5 0.0754 5440300 20.5 1.8 2.8 63.0 0.0601 6740
0.6/1kV F-FR-8 (2 Cores)
3.5
1.8
0.7
0.9
1.1Compacted
Circular
1.5 7 / 0.53 1.59 15.0 12.1 1702.5 7 / 0.67 2.01 16.0 7.41 2004 7 / 0.85 2.55 0.7 17.0 4.61 2706 7 / 1.04 3.12 1.8 18.5 3.08 34010 7 / 1.35 4.05 20.5 1.83 47016 4.7 22.0 1.15 64025 5.9 0.9 26.0 0.727 93035 6.9 28.5 0.524 3.5 125050 8.1 1.0 1.9 32.0 0.387 160070 ø¯«¸æ–√‡ø¨º± 9.8 1.1 2.0 37.0 0.268 224095 11.4 2.1 41.0 0.193 3020120 12.9 1.2 2.3 45.5 0.153 3850150 14.4 1.4 2.4 50.5 0.124 4790185 15.9 1.6 2.6 55.5 0.0991 5960240 18.3 1.7 2.8 62.0 0.0754 7730300 20.5 1.8 2.9 68.0 0.0601 9570
0.6/1kV F-FR-8 (3 Cores)
3.5
1.8
0.7
0.9
1.1Compacted
Circular
1.5 7 / 0.53 1.59 16.0 12.1 1902.5 7 / 0.67 2.01 17.0 7.41 2504 7 / 0.85 2.55 0.7 18.5 4.61 3306 7 / 1.04 3.12 1.8 20.0 3.08 42010 7 / 1.35 4.05 22.5 1.83 60016 4.7 24.5 1.15 82025 5.9 0.9 28.5 0.727 122035 6.9 31.5 0.524 3.5 160050 8.1 1.0 2.0 35.5 0.387 211070 9.8 1.1 2.1 41.0 0.268 299095 ø¯«¸æ–√‡ø¨º± 11.4 2.3 45.5 0.193 4040120 12.9 1.2 2.4 50.5 0.153 5050150 14.4 1.4 2.6 56.0 0.124 6280185 15.9 1.6 2.7 61.5 0.0991 7830240 18.3 1.7 3.0 69.0 0.0754 10160300 20.5 1.8 3.2 76.0 0.0601 12600
0.6/1kV F-FR-8 (4 Cores)
1.8
0.7
0.9
1.1Compacted
Circular
3.5
Conductor Insulation Sheath Approx. D.C Conductor Test Approx.Nominal Cross Section Construction Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Conductor Insulation Sheath Approx. D.C Conductor Test Approx.Nominal Cross Section Construction Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Conductor Insulation Sheath Approx. D.C Conductor Test Approx.Nominal Cross Section Construction Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
-
RailsolTM_Xcel PowerAAC, AAAC 12
RailsolTM_Xcel Power
RailsolTM_Xcel AAC, AAAC
ApplicationOverhead lines, Feeder, Earthing conductor, Return conductor
Design StandardEN 50182
Brief Description of Various ProductsAAC and AAAC have been widely used in the field of overhead transmission and distribution lines as it is lighter in weight,lower in cost and higher in tensile strength than the copper transmission line.
ConstructionAll aluminum conductor(AAC) is composed of hard-drawn alumium only.All aluminum alloy conductor(AAAC) is composed of aluminum-alloy AA6201 only.
A2C-34 34.4 7 2.50 7.5 93.9 6.01 180
A2C-93 93.3 19 2.50 12.5 256.3 16.32 340
A2C-182 181.6 37 2.50 17.5 500.9 31.78 520
A2C-400 400.1 61 2.89 26.0 1107.1 68.02 855
A2C-500 499.8 61 3.23 29.1 1382.9 82.47 990
A3C-34 34.4 7 2.50 7.5 93.9 10.14 170
A3C-93 93.3 19 2.50 12.5 256.3 27.51 320
A3C-182 181.6 37 2.50 17.5 500.9 53.58 490
A3C-400 400.1 61 2.89 26.0 1107.1 118.04 810
A3C-500 499.8 61 3.23 29.1 1382.9 147.45 930
NominalCross
Section(mm2)
CalculatedCross
Section(mm2)
Number of
Wires
Diameter
Wire Conductor(mm) (mm)
ContinousCurrent-Carrying
Capacity(A)
CalculatedBreaking
Load(kN)
Weight
(kg / km)
Other dimensions available on enquiry
Technical Data of AAC(A2C) and AAAC(A3C)
-
ApplicationDistribute power from a railway substation to a station
Design StandardKS C 3313, KEPCO Spec : ESA 124-020-084
Construction Technical Data Conductor Solid or stranded hard-drawn copper
Insulation Weather proof black PVC
RailsolTM_Xcel Outdoor Weather Proof PVC Insulated Wire
Voltage 600 V
3 1/2.0 2.0 0.4 2.8 5.83 134.0 32
5.5 1/2.6 2.6 0.5 3.6 3.45 223.2 54
8 1/3.2 3.2 0.6 4.4 2.28 333.0 81
12 1/4.0 4.0 1.0 6.0 1.46 499.1 135
20 1/5.0 5.0 1.2 7.4 0.93 759.8 210
14 7/1.6 4.8 1.0 6.8 1.35 574 160
22 7/2.0 6.0 1.2 8.4 0.85 889 250
30 7/2.3 6.9 1.2 9.3 0.64 1169 320
38 7/2.6 7.8 1.4 11.0 0.50 1480 410
50 19/1.8 9.0 1.4 12.0 0.39 1960 520
60 19/2.0 10.0 1.4 13.0 0.31 2410 630
80 19/2.3 11.5 1.5 14.5 0.24 3160 820
100 19/2.6 13.0 1.5 16.0 0.19 4010 1030
Nominal Conductor Insulation Approx. D.C Conductor Tension Approx.Cross Section Construction Diameter Thickness Overall Diameter Resistance Load Weight
(mm2) (No / mm) (mm) (mm) (mm) ( / m) (kg) (kg / km)
Other dimensions available on enquiry
RailsolTM_Xcel Power Outdoor Weather Proof PVC Insulated Wire13
-
RailsolTM_Xcel Power
RailsolTM_Xcel Power450 / 750V HIV 14
RailsolTM_Xcel 450 / 750V HIV
ApplicationType HIV is used for wiring inside of house and building at max. conductor temperature 90
Design StandardIEC 60227-3
1.5 0.7 2.6 3.2 12.1 0.011 2.5 20
1.5 0.7 2.7 3.3 12.1 0.010 2.5 20
2.5 0.8 3.2 3.9 7.41 0.009 2.5 40
2.5 0.8 3.3 4.0 7.41 0.009 2.5 40
4 0.8 3.6 4.4 4.61 0.0085 2.5 50
4 0.8 3.8 4.6 4.61 0.0077 2.5 50
6 0.8 4.1 5.0 3.08 0.0070 2.5 70
6 0.8 4.3 5.2 3.08 0.0065 2.5 70
10 1.0 5.3 6.4 1.83 0.0070 2.5 120
10 1.0 5.6 6.7 1.83 0.0065 2.5 120
16 1.0 6.4 7.8 1.15 0.0050 2.5 170
25 1.2 8.1 9.7 0.727 0.0050 2.5 260
35 1.2 9.0 10.9 0.524 0.0043 2.5 350
50 1.4 10.6 12.8 0.387 0.0043 2.5 480
70 1.4 12.1 14.6 0.268 0.0035 2.5 670
95 1.6 14.1 17.1 0.193 0.0035 2.5 920
120 1.6 15.6 18.8 0.153 0.0032 2.5 1,160
150 1.8 17.3 20.9 0.124 0.0032 2.5 1,430
185 2.0 19.3 23.3 0.0991 0.0032 2.5 1,780
240 2.2 22.0 26.6 0.0754 0.0032 2.5 2,320
300 2.4 24.5 29.6 0.0601 0.0030 2.5 2,930
400 2.6 27.5 33.2 0.0470 0.0028 2.5 3,730
450 / 750V HIV
Cross Scetion
(mm2)
InsulationThickness
(mm)
D.C ConductorResistance
(20 )( km)
InsulationResistance
(90 )
(M km)
Test Voltage
(kV)
Approx.Weight
(kg / km)
Minimum Maximum(mm) (mm)
Approx. Overall Diameter
ConstructionConductor Solid or stranded annealed copper, class 1 or class 2
Insulation Heat-, abrasion and moisture-resistant PVC, 90
Other dimensions available on enquiry
-
1.5 7 / 0.53 1.59 6.5 12.1 60
2.5 7 / 0.67 2.01 7.0 7.41 80
4 7 / 0.85 2.55 8.0 4.61 110
6 7 / 1.04 3.12 8.5 3.08 130
10 7 / 1.35 4.05 9.5 1.83 180
16 4.7 10.0 1.15 230
25 5.9 12.0 0.727 340
35 6.9 13.0 0.524 440
50 8.1 14.5 0.387 570
70 9.8 16.0 0.268 780
95 11.4 18.5 0.193 1060
120 12.9 20 0.153 130
150 14.4 3.4 22 0.124 1600
185 15.9 3.7 25 0.0991 1980
240 18.3 4.0 28 0.0754 2580
300 20.5 4.3 30 0.0601 3210
400 23.2 4.6 34 0.0470 4050
500 26.4 4.9 38 0.0366 5150
630 30.2 5.0 42 0.0283 6570
RailsolTM_Xcel 0.6 / 1kV F-GV
Construction
Constructional Data (Nominal Values)
Conductor Stranded or compacted stranded annealed copper, class2
Insulation Abrasion and moisture-resistant FR-PVC
Other dimensions available on enquiry
3.5
2.2
2.4
2.6
2.8
3.1Compacted
Circular
ApplicationType F-GV is used for grounding wire
Design StandardIEC 60502-1
RailsolTM_Xcel Power 0.6 / 1kV F-GV15
Conductor Insulation Overall Conductor Test Approx.Nominal Cross Section Construction Outer Diameter Thickness Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
-
ApplicationType F-CVV-S, F-CVV-SB is used for control circuits in underground duct, conduit and open air.
Design StandardIEC 60502-1 : Power Cables with extruded insulation and their accessories for rated voltages
from 1kV (Um = 1.2kV) up to 30 kV (Um = 36kV) ; Part1 : Cables for rated voltages of 1kV (Um = 1.2kV) and 3kV (Um = 3.6kV)
Construction
Core Identification
RailsolTM_Xcel 0.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB
1.5 7/0.53 1.59 0.8 1.8 12.0 12.1 3.5 170
2.5 7/0.67 2.01 0.8 1.8 13.0 7.41 3.5 200
2 4 7/0.85 2.55 1.0 1.8 14.5 4.61 3.5 280
6 7/1.04 3.12 1.0 1.8 16.0 3.08 3.5 340
10 7/1.35 4.05 1.0 1.8 17.5 1.83 3.5 460
1.5 7/0.53 1.59 0.8 1.8 12.5 12.1 3.5 200
2.5 7/0.67 2.01 0.8 1.8 13.5 7.41 3.5 250
3 4 7/0.85 2.55 1.0 1.8 15.5 4.61 3.5 350
6 7/1.04 3.12 1.0 1.8 17.0 3.08 3.5 440
10 7/1.35 4.05 1.0 1.8 18.5 1.83 3.5 600
1.5 7/0.53 1.59 0.8 1.8 13.5 12.1 3.5 250
2.5 7/0.67 2.01 0.8 1.8 14.5 7.41 3.5 310
4 4 7/0.85 2.55 1.0 1.8 16.5 4.61 3.5 430
6 7/1.04 3.12 1.0 1.8 18.0 3.08 3.5 550
10 7/1.35 4.05 1.0 1.8 20.5 1.83 3.5 760
2
3
4
Conductor Stranded annealed copper, class 2Insulation PVC(70 )Assembly Multi-cores of cable shall be assembled to form a circular cableShield The copper tape or copper braid shield is applied helically around the assembled cable coresSheath Black flam retardant PVC(FR-PVC)
RailsolTM_Xcel Power
RailsolTM_Xcel Power0.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB 16
3.5
No.of
Cores
InsulationThickness
(mm)Construction
(No / mm)
ConductorApprox.
Overall Diameter(mm)
D.C ConductorResistance(20 C)
( / km)
Test Voltage
(kV)
Approx. Weight
(kg / km)
SheathThickness
(mm)Nominal Cross Section
(mm2)OuterDiameter
(mm)
-
1.5 7/0.53 1.59 0.8 1.8 14.5 12.1 3.5 290
2.5 7/0.67 2.01 0.8 1.8 15.5 7.41 3.5 360
5 4 7/0.85 2.55 1.0 1.8 18.0 4.61 3.5 520
6 7/1.04 3.12 1.0 1.8 19.5 3.08 3.5 660
10 7/1.35 4.05 1.0 1.8 22.5 1.83 3.5 920
1.5 7/0.53 1.59 0.8 1.8 15.5 12.1 3.5 330
2.5 7/0.67 2.01 0.8 1.8 16.5 7.41 3.5 420
6 4 7/0.85 2.55 1.0 1.8 19.5 4.61 3.5 620
6 7/1.04 3.12 1.0 1.8 21.5 3.08 3.5 780
10 7/1.35 4.05 1.0 1.8 24.5 1.83 3.5 1,090
1.5 7/0.53 1.59 0.8 1.8 15.5 12.1 3.5 360
2.5 7/0.67 2.01 0.8 1.8 16.5 7.41 3.5 460
7 4 7/0.85 2.55 1.0 1.8 19.5 4.61 3.5 670
6 7/1.04 3.12 1.0 1.8 21.5 3.08 3.5 860
10 7/1.35 4.05 1.0 1.8 24.5 1.83 3.5 1,210
1.5 7/0.53 1.59 0.8 1.8 16.5 12.1 3.5 410
2.5 7/0.67 2.01 0.8 1.8 17.5 7.41 3.5 520
8 4 7/0.85 2.55 1.0 1.8 21.5 4.61 3.5 780
6 7/1.04 3.12 1.0 1.8 23.5 3.08 3.5 990
10 7/1.35 4.05 1.0 1.8 26.5 1.83 3.5 1,400
1.5 7/0.53 1.59 0.8 1.8 18.5 12.1 3.5 500
2.5 7/0.67 2.01 0.8 1.8 20.5 7.41 3.5 640
10 4 7/0.85 2.55 1.0 1.8 24.5 4.61 3.5 950
6 7/1.04 3.12 1.0 1.8 26.5 3.08 3.5 1,220
10 7/1.35 4.05 1.0 1.8 30.5 1.83 3.5 1,720
1.5 7/0.53 1.59 0.8 1.8 18.5 12.1 3.5 570
2.5 7/0.67 2.01 0.8 1.8 20.5 7.41 3.5 730
12 4 7/0.85 2.55 1.0 1.8 25.5 4.61 3.5 1,090
6 7/1.04 3.12 1.0 1.8 27.5 3.08 3.5 1,400
10 7/1.35 4.05 1.0 1.8 31.5 1.83 3.5 2,000
1.5 7/0.53 1.59 0.8 1.8 20.5 12.1 3.5 680
15 2.5 7/0.67 2.01 0.8 1.8 22.5 7.41 3.5 890
4 7/0.85 2.55 1.0 1.8 27.5 4.61 3.5 1,330
6 7/1.04 3.12 1.0 1.8 29.5 3.08 3.5 1,720
1.5 7/0.53 1.59 0.8 1.8 22.0 12.1 3.5 870
20 2.5 7/0.67 2.01 0.8 1.8 25.0 7.41 3.5 1,130
4 7/0.85 2.55 1.0 1.8 30.0 4.61 3.5 1,710
6 7/1.04 3.12 1.0 1.8 33.0 3.08 3.5 2,230
1.5 7/0.53 1.59 0.8 1.8 26.0 12.1 3.5 1,230
30 2.5 7/0.67 2.01 0.8 1.8 29.0 7.41 3.5 1,620
4 7/0.85 2.55 1.0 1.8 36.0 4.61 3.5 2,480
5
6
7
8
10
12
15
20
30
RailsolTM_Xcel Power 0.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB17
Other dimensions available on enquiry
3.5
No.of
Cores
InsulationThickness
(mm)Construction
(No / mm)
ConductorApprox.
Overall Diameter(mm)
D.C ConductorResistance(20 C)
( / km)
Test Voltage
(kV)
Approx. Weight
(kg / km)
SheathThickness
(mm)Nominal Cross Section
(mm2)OuterDiameter
(mm)
-
RailsolTM_Xcel Power
RailsolTM_Xcel Power154kV HV Power Cable 18
300 20.4 1.5 17 1.3 1.5 x 80 4.5 72 6.3 0.0601 0.21
400 23.2 1.5 17 1.3 1.5 x 80 4.5 75 7.2 0.0470 0.23
500 26.3 1.5 17 1.3 1.5 x 80 4.5 79 8.6 0.0366 0.25
630 30.2 1.5 17 1.3 1.5 x 80 4.5 83 10.1 0.0283 0.28
800 34.0 1.5 17 1.3 1.5 x 80 4.5 87 12.0 0.0221 0.30
1000 38.7 1.5 17 1.3 1.5 x 80 4.5 92 14.4 0.0176 0.33
1200 41.8 1.5 17 1.3 1.5 x 80 4.5 98 16.7 0.0151 0.36
1600 48.1 1.5 17 1.3 1.5 x 80 4.5 105 20.9 0.0113 0.40
2000 54.3 1.5 17 1.3 1.5 x 80 4.5 112 25.4 0.0090 0.44
2500 63.0 1.5 17 1.3 1.5 x 80 4.5 118 31.1 0.0072 0.34
RailsolTM_Xcel 154kV HV Power Cable
Construction
Constructional Data (Nominal Values)
Conductor Copper
Insulation XLPE
Shield Copper Wire
Sheath PE (PVC)
Other dimensions available on enquiry
Continuous Current Ratings for Single Circuit (A)
300 591 553 684 765
400 673 629 789 887
500 766 713 907 1027
630 871 829 1043 1193
800 977 928 1181 1367
1000 1143 1081 1415 1639
1200 1232 1208 1535 1790
1600 1404 1382 1765 2100
2000 1554 1523 1973 2384
2500 1636 1603 2077 2510
Cross Section Direct Buried Pipe Duct In Air(mm2) Trefoil Flat (S=2D)
Compact Round
Stranded
CrossSection
(mm2)
Segment Tranded(Miliken)
ConstructionShape
Diameter
(mm)
Thickness ofConductor
Screen Approx(mm)
Insulation Thickness
(mm)
Thickness ofInsulation
Screen Approx. (mm)
Diameter andNumber of
Copper Wires(mm No)
Thickness ofOuter
Sheath(mm)
Outer Diameterof Cable(mm)
Weight ofCable
(mm)
Max. DCConductor
Resistance at 20( / km)
Capacitance
( / km)
-
ApplicationConnect a power plant to a substationConnect a substation to a railway substation
Construction Technical Data Conductor Concentric, compacted circular (less than
800mm2)and segmental compacted circular(Over 1000mm2)
Insulation Extruded cross-linked polyethyleneConductor/ Semi-conducting thermosetting compoundInsulation Screen Conductor screen, Insulation and Insulation
screen are extruded by triple extrustionMetallic Shield Screen Copper wire shield
Sheath Lead sheath and corrugated aluminum sheath are available.
Outer Sheath PE or PVC
RailsolTM_Xcel 132kV HV Power Cable
Voltage 132kV
132kV Aluminum sheath type
630 30.2 0.21 856
800 34.0 0.23 956
1000 38.7 0.25 1103
1200 41.8 0.27 1185
1600 48.3 0.30 1333
2000 54.3 0.32 1452
Cross Section Conductor Diameter Capacitance Current Rating(mm2) (mm) ( /km) (A)
Directly Buried TypeFor out of above range, Refer to LS EHV Cable System Catalogue
RailsolTM_Xcel Power 132kV HV Power Cable19
Other dimensions available on enquiry
-
RailsolTM_Xcel Power
ConstructionConductor Copper
Insulation XLPE
Sheath Aluminum
Sheath PE (PVC)
Continuous Current Ratings for Single Circuit(A)
RailsolTM_Xcel 36/66kV with Aluminum Sheath
RailsolTM_Xcel Power36/66kV with Aluminum Sheath 20
240 524 491 598 671
300 592 556 682 770
400 671 631 781 888
500 762 714 894 1025
630 878 808 1023 1187
800 965 928 1150 1355
1000 1119 1075 1361 1615
1200 1198 1146 1460 1745
1600 1352 1357 1654 2030
2000 1468 1475 1800 2273
Cross Section(mm2) Direct Buried Pipe Duct Trefoil Flat (S=2D)
In Air
Constructional Data (Nominal Values)
18.1 1.0 11.0 1.0 1.6 3.5 69 5.5 0.0754 0.20
20.4 1.0 11.0 1.0 1.6 3.5 72 6.3 0.0601 0.21
23.2 1.0 11.0 1.0 1.7 3.5 75 7.2 0.0470 0.23
26.3 1.0 11.0 1.0 1.8 4.0 79 8.6 0.0366 0.25
30.2 1.0 11.0 1.0 1.8 4.0 83 10.1 0.0283 0.28
34.0 1.0 11.0 1.0 1.9 4.0 87 12.0 0.0221 0.30
38.7 1.0 11.0 1.0 2.0 4.0 92 14.4 0.0176 0.33
41.8 1.0 11.0 1.0 2.1 4.5 98 16.7 0.0151 0.36
48.1 1.0 11.0 1.0 2.2 4.5 105 20.9 0.0113 0.40
54.3 1.0 11.0 1.0 2.4 4.5 112 25.4 0.0090 0.44
240
300
400
500
630
800
1000
1200
1600
2000
Other dimensions available on enquiry
Conductor
Cross Section (mm2)
Shape Diameter
Thickness ofConductor Screen
Approx.(mm)
InsulationThickness
(mm)
Thickness ofInsulation Screen
Approx.(mm)
Thickness ofAluminum
Sheath(mm)
Thickness of Outer
Sheath(mm)
Outer Diameterof Cable(mm)
Weight of
Cable(kg / m)
Max. DC Conductor
Resistance at 20( / km)
Capacitance
( nF/ km)
Compact
Round
Stranded
Segment
Stranded
(Miliken)
-
RailsolTM_Xcel 36/66kV with Lead Sheath
RailsolTM_Xcel Power 36/66kV with Lead Sheath21
ConstructionConductor Copper
Insulation XLPE
Sheath Lead
Sheath PE (PVC)
Continuous Current Ratings for Single Circuit (A)
240 535 525 621 706
300 606 567 710 810
400 691 646 822 942
500 787 733 951 1098
630 898 833 1096 1274
800 1008 958 1243 1462
1000 1184 1121 1505 1759
1200 1282 1208 1648 1938
1600 1469 1434 1906 2282
2000 1626 1585 2130 2597
Cross Section (mm2) Direct Buried Pipe Duct Trefoil Flat (S=2D)
In Air
Constructional Data (Nominal Values)
18.1 1.0 11.0 1.0 2.1 3.5 62 8.1 0.0754 0.20
20.4 1.0 11.0 1.0 2.2 3.5 64 9.1 0.0601 0.21
23.2 1.0 11.0 1.0 2.3 3.5 67 10.5 0.0470 0.23
26.3 1.0 11.0 1.0 2.4 4.0 72 12.5 0.0366 0.25
30.2 1.0 11.0 1.0 2.4 4.0 76 14.2 0.0283 0.28
34.0 1.0 11.0 1.0 2.6 4.0 80 16.9 0.0221 0.30
38.7 1.0 11.0 1.0 2.7 4.0 85 19.9 0.0176 0.33
41.8 1.0 11.0 1.0 2.8 4.5 91 23.0 0.0151 0.36
48.1 1.0 11.0 1.0 3.0 4.5 97 28.0 0.0113 0.40
54.3 1.0 11.0 1.0 3.2 4.5 104 33.4 0.0090 0.44
240
300
400
500
630
800
1000
1200
1600
2000
Other dimensions available on enquiry
Conductor
CrossSection(mm2)
Shape Diameter
Thickness ofConductor Screen
Approx.(mm)
InsulationThickness
(mm)
Thickness ofInsulation Screen
Approx.(mm)
Thickness ofLead
Sheath(mm)
Thickness of Outer
Sheath(mm)
Outer Diameterof Cable(mm)
Weight of
Cable(kg / m)
Max. DC Conductor
Resistance at 20( / km)
Capacitance
( nF/ km)
Compact
Round
Stranded
Segment
Stranded
(Miliken)
-
ApplicationConnect a railway substation to a station
Design StandardIEC 60502, 61034, 60754
Construction Technical Data Annealed copper, Hard aluminum strandedwires, Compacted circular and segmentalcompacted circular1core (12/20kV : 35mm2 ~ 1000mm2)
(18/30kV : 50mm2 ~ 1000mm2)3core ( ~ 400mm2)
Insulation XLPE, TR-XLPE
Sheath PVC(ST2), PE(ST7), Halogen-free(ST8)
Metallic screen Copper tape or wire shield
Core Color 3 core (Red, Yellow, Blue)
RailsolTM_Xcel 12/20kV, 18/30kV MV Power Cable
Voltage 12/20kV, 18/30kV
12/20kV MV Power Cable
35 4.7 5.5 1.8 27 0.524 42 860
50 8.1 5.5 1.8 28 0.387 42 1010
70 9.8 5.5 1.8 30 0.268 42 1250
95 11.4 5.5 1.9 31 0.193 42 1530
120 12.9 5.5 1.9 33 0.153 42 1790
150 14.4 5.5 2.0 34 0.124 42 2090
185 15.9 5.5 2.0 36 0.0991 42 2470
240 18.3 5.5 2.1 39 0.0754 42 3060
300 20.5 5.5 2.2 41 0.0601 42 3680
400 23.2 5.5 2.3 44 0.0470 42 4540
500 26.4 5.5 2.4 47 0.0366 42 5620
630 30.2 5.5 2.5 52 0.0283 42 7040
Other dimensions available on enquiry
RailsolTM_Xcel Power
RailsolTM_Xcel Power12/20kV, 18/30kV MV Power Cable 22
ConductorCrossSectional Area
Conductor
Nominal Cross Section(mm2)
Construction(No / mm) Diameter
InsulationThickness
(mm)
SheathThickness
(mm)
Apporx.Overall Diameter
(mm)
D.C ConductprResistance(20 )
(M / km)
TestVoltage
(kV)
Approx.Weight
(kg / km)
Conductor
Compacted
Circular
-
RailsolTM_Xcel Power 12/20kV, 18/30kV MV Power Cable 23
18/30kV MV Power Cable
70 9.8 8.0 2.0 36 0.268 63 1720
95 11.4 8.0 2.1 38 0.193 63 2040
120 12.9 8.0 2.1 40 0.153 63 2360
150 14.4 8.0 2.1 41 0.124 63 2670
185 15.9 8.0 2.2 43 0.0991 63 3110
240 18.3 8.0 2.3 46 0.0754 63 3820
300 20.5 8.0 2.4 48 0.0601 63 4510
400 23.2 8.0 2.5 51 0.0470 63 5440
500 26.4 8.0 2.5 55 0.0366 63 6600
630 30.2 8.0 2.7 60 0.0283 63 8300
Other dimensions available on enquiry
Nominal Cross Section(mm2)
Construction(No / mm) Diameter
InsulationThickness
(mm)
SheathThickness
(mm)
Apporx.Overall Diameter
(mm)
D.C ConductprResistance(20 )
(M / km)
TestVoltage
(kV)
Approx.Weight
(kg / km)
Conductor
Compacted
Circular
-
RailsolTM_Xcel Power8.7/15kV MV Power Cable 24
RailsolTM_Xcel 8.7/15kV MV Power Cable
ApplicationConnect a railway substation to a station
Design StandardIEC 60092-350, -354, -359, IEC 60332-1, -3
Construction Technical Data Conductor Tinned annealed copperConductor Screen Semi-conductive tape plus compound
Insulation Material EPR to IEC 60092-351
Insulation Screen Semi-conductive compound plus tape
Inner Covering High modulus PVC
Sheath Material Enhanced PVC to IEC 60092-359Conductor Cross
25 ~ 185mm2Sectional Area
Shield Annealed copper wire metallic screen
Core 3 core (Red, white, blue)
Voltage 8.7 / 15 kV
1 / 3 25 25.8 / 51.6 800 / 2690
1 / 3 35 27.1 / 54.8 930 / 3200
1 / 3 50 28.7 / 58.4 1130 / 3850
1 / 3 70 30.6 / 62.3 1370 / 4660
1 / 3 95 33.4 / 67.6 1720 / 5740
1 / 3 120 35.1 / 71.7 1930 / 6510
1 / 3 150 37.0 / 75.6 2350 / 7880
1 / 3 185 38.9 / 79.7 2650 / 8880
1 240 41.5 3340
1 300 44.6 4040
No. of CoresCross Section Outer Diameter Approx Weight
(mm2) (mm) (kg / km)
Other dimensions available on enquiry
RailsolTM_Xcel Power
-
RailsolTM_Xcel Power EHV Cable Joints & Terminations25
Pr-Molded Joints
RailsolTM_Xcel EHV Cable Joints & Terminations
72.5kV up to 420kVConductor ~2500SQmm2
Pre-molded one piece type designSilicone-based rubber sleeveCasing / Coffin-box
72.5kV up to 420kVConductor ~2500SQmm2
XLPE-OF Cable transitionPrefabricated type design
72.5kV up 123kVConductor ~2000SQmm2
Dry type designSilicone-based one piece stress relief cone and bushing
72.5kV up to 420kVConductor ~2500SQmm2
Dry type designEPR-based stress relief coneEpoxy housing
Transition Joints
SF6 Immersed Sealing Ends
72.5kV up to 420kVConductor ~2500SQmm2
Dry type designEPR-based stress relief coneEpoxy housing
Outdoor(Dry type) Terminations
Oil Immersed Transformer Terminations
Outdoor(Slip-on type) Terminations
72.5kV up to 420kVConductor ~2500SQmm2
Pre-molded slip-on type designSilicone - based stress relief cone Porcelain or polymer bushing
All of the accessories for EHV cable could be supplied with optical fiber joint and PD sensor depending on optional requirements.
-
RailsolTM_Xcel Power
RailsolTM_Xcel PowerMV Cable Joints & Terminations 26
RailsolTM_Xcel MV Cable Joints & Terminations
Mechanical joint closures :Joint 3.3kV (2 35, AL), Joint 12/20kV
MV Cold shrink joint closures :Joint 6.6/11kV, Joint 12/20kV, Joint 19/33kV
MV Heat-shrink Terminations :No sheds for indoor applications up to 42kVUnique zinc oxide stress control systemSimple to installation
MV Cold-shrink terminations :11kV (single or three core)11kV Copper wire, copper tape screen cable11kV Outdoor/Indoor33kV polymeric insulated copper wire screen cables.33kV copper wire tape screen33kV indoor/outdoor single/three core 35 ~ 630mm2
Up to 25/46 kV
Structure
Product Medium voltage joints and terminations for polymeric insulated cables up to 36kVCross section : 25mm2 ~ 600mm2
Indoor and outdoorHeat shrinkable and cold shrinkable type Mechanical and compression connector
Bushing (Type C)Mechanical ConnectorConductive EPDM InsertEPDM Insulation layerConductive EPDM JacketConductive Rubber CapBasic Insulating PlugConductor connector Cable reducerEarthing lead
-
RailsolTM_Xcel Cable LV Cable Joints27
RailsolTM_Xcel LV Cable Joints
Heat-shrink typeVoltage : 0.6/1kVType : Plastic and paper insulated Core : 3 core, 4 core, 5 core cableMaterial : XLPEHot-melt adhesive
Tape typeVoltage : 0.6/1kV Type : Plastic-insulated cablesCore : 3-, 4-, 5- coresMaterial : insulating vulcanized tape and electrical tapeCross Section : 70 ~ 150mm2
With- or without screen
Resin Joint typeVoltage : 0.6/1kVType : branch or straight typeCompression or mechanical Cross Section : 4mm2~ 400mm2
Armour bondHF and No toxic emission
Joints for plastic insulated multi-core control cablesHeat shrinkable joints for control cablesCross section : 4 ~ 75 X 1.5mm2~2.5mm2
-
Signaling ATPTrack CircuitCBTCSwitch PointSignal PostSignal Facility Room
2
-
ATPBalise Cable 1Axle Counter Cable 2
Track CircuitAF Track Circuit Cable [DC] 4AF Track Circuit Cable [DC] F-SUIREE-S 5AF Track Circuit Cable [AC] 6450 / 750V KIV 200.6/1kV F-CVV 14
CBTCOptical Fiber Cables [SM] 24Optical Fiber-Copper Composite Cable 26
Switch Point0.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB 160.6/1kV F-CV 12
Signal Post0.6/1kV F-CV 120.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB 16F-GV 22Aluminum Power Cable 23
Signal Facility RoomZCO3 8ZPFU 9ZPAU 10ZUG/SUG/ZUT 11K23 21Digicode Cable 70.6/1kV F-FR-8 180.6/1kV F-CVV-S, 0.6/1kV F-CVV-SB 16Category6 UTP Cable 4 Pair 27Category6 F/UTP Cable 4 Pair 28Category6 SF/UTP Cable 4 Pair 29Optical Fiber Cable Accessory 25F-GV 22
Signaling
-
ATP(PAGE : 1,2)
Track Circuit(PAGE : 4, 5, 6, 14, 20)
Signal Facility Room(PAGE : 7, 8, 9, 10, 11, 16, 18, 21, 22, 25, 27, 28, 29)
-
Signal Post(PAGE : 12, 16, 22, 23)
CBTC(PAGE : 24, 26)
Switch Point(PAGE : 12, 16)
-
Application BusinessThe Leading Solution Provider, LS Cable introduced a new maketing concept, which is providingCollected items applicable to an industry as a package instead of separately providing a single item.This LS Cable s business solutions are applicable to following industries : Wind Power Generation,Railway & Rolling stock, Airport, Power Transmission & distribution, Marine & Offshore, and Automotive. The Application Business manages various departments and their products to satisfy our customers pecific needsand convenience.
-
ApplicationERTMS System
Construction Technical Data Conductor Stranded tinned copper, class 2
Insulation Colored PE
Sheath PE dielectric
Shield Copper braid
Inner Sheath PE, watertight
Armour Galvanized steel braid
Outer Jacket PVC
RailsolTM_Xcel Balise Cable
RailsolTM_Xcel Signaling Balise Cable1
Operation Temp. -25~+85
Linear Resistance 22 /km
Impedance 95 100 kHz ~ 1 MHz
Linear Attenuation Max. 7.5 dB/km 560 KHz
Max. 10 dB/km 1 MHz
Min. Bending Radius 8 x D (Static), 16 x D (Dynamic)
Installed in Channel
Mineral oil Resistant / Fuel Resistant / Ozone Resistant
2 0.85 7/0.386 2.3 15.0 301
No.of Cores Cross Section Construction Insulated Core Overall Diameter Net Weight(mm2) (No / mm) (mm) (mm) (kg / km)
Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Axle Counter Cable
RailsolTM_Xcel Signaling Axle Counter Cable 2
ScopeThis specification covers the requirements for axle Counter Cable used to railway system.
Cable Description and Symbol
Construction and Material1. Conductor
The conductor shall consist of stranded tinned annealed copper wire complying with ASTM B33
2. InsulationThe conductor shall be uniformly covered with cross-linked polyethylene(XLPE) compound.The minimum average thickness and minimum thickness at any point shall be not less than the value in the attached table.
3. TwinningTwo insulated cores shall be uniformly twisted together to form a pair with a drain wire.And an aluminum-polyester tape shall be helically applied over the twisted pair with the metallic side down in electrical contact with a drain wire. If necessary, the binder tape may be applied overlap the aluminum-polyester tape. The color of pairs shall be as follow table.
4. AssemblyEach twisted pair shall be uniformly assembled with the left-hand lay(S) and a polyester tape may be helically applied over the assembled layer with a drain wire. If necessary, suitable non-hygroscopic filler may be applied between the pairs to form a circular cross-section
5. ShieldThe shield shall be helically applied over the assembly layer with a layer of copper tape anda suitable binder tape may be helically applied over the shield.The thickness of copper tape shall be given in the attached table.
6. Shield (Jacket)The shield shall be applied uniformly over the shield layer with cross-linked flame retardant halogen-free compound.The minimum average thickness and minimum thickness at any point shall be not less than the value in the attached table.The color of sheath shall be black.
Description Symbol
XLPE insulated, Individually Al / mylar shielded, Copper tape shielded, cross-linked halogen free sheathed,Individually pair type cable
AXEE-S
Other dimensions available on enquiry
1 Black-Red 7 Black-Orange
2 Black-White 8 Red-White
3 Black-Green 9 Red-Green
4 Black-Blue 10 Red-Blue
5 Black-Yellow 11 Red-Yellow
6 Black-Brown
Pair No. Pair Color Pair No. Pair Color
-
RailsolTM_Xcel Signaling Axle Counter Cable3
Item Unit Specified Values
Item Unit Specfied value
Cable Characteristics and Test
Before agingTensile Strength N/mm2 Min. 0.8
Elongation % Min. 160Sheath
AgedTensile Strength % Min. 60 (130 /120hr)
Elongation % Min. 60 (130 /120hr)
Spark Test V ac 2000 (During process)
Heat Shock Test (200 /4hr) - No Cracks
Cold bend Test (-30±3 /4hr) - No Cracks
Conductor Resistance (20 ) /km Max. 54.84
Insulation Resistance (20 ) M /km Min. 1000
Voltage Test (Conductor to Conductor) V/1min. 2000 (No break down)
Voltage Test (Conductor to Drain wire) V/1min. 2000 (No break down)
Mutual Capacitance(1KHz) nF/ km Nom. 97
Grounded Capacitance(1KHz) nF/ km Nom. 174
Velocity of Propagation - 65%
AgedTensile Strength % Min. 60 Diesel Fuel
Elongation % Min. 60 (100 /24hr)
ChemicalAged
Tensile Strength % Min. 60 ASTM No.2
Resistance Elongation % Min. 60 (100 /24hr)
AgedTensile Strength % Min. 50 MIL-L-23699
Elongation % Min. 50 (50 /24hr)
Halogen Acid Gas Emission Test - Max. the amount of halogen acid gas : 0.5%
Oxygen Index (ATSM D 2863) - Min. 35
Attennuation 1MHz dB/100m Nom. 4.1
Flammability Test - IEC 60332-3-24
Attached Table
Conductor No. of Pair EA 3 10 11
Size AWG 22
Construction No/mm 7/0.254
Diameter mm Nom. 0.76
Insulation Min. Average Thick. mm 0.2 0.25
Min. Thick. At any Point mm 0.18 0.22
Diameter mm Approx. 1.26 Approx. 1.36
The Construction of Drain Wire No/mm 7/0.254 (Tinned Annealed Copper)
Thickness of Al / Mylar tape mm Nom. 0.025
Thickness of Copper Tape (Shield) mm Approx. 0.09
Sheath Min. Average Thick mm 0.95 1.3 1.3
(Jacket) Min. Thick. at Any Point mm 0.85 1.2 1.2
Diameter Approx. Approx. Approx.
8.2 14.5 14.5
( 0.5) ( 0.5) ( 0.5)
Standard Packing Length m 300
Conductor
Sheath(Jacket) Approx. Approx. Approx.
Diameter mm 8.2 14.5 14.5( 0.5) ( 0.5) ( 0.5)
Insulation
Option:Armoured Type(AXEEWAU-S)
-
RailsolTM_Xcel Signaling
RailsolTM Xcel AF Track Circuit Cable (DC)
RailsolTM_Xcel Signaling AF Track Circuit Cable (DC) 4
ApplicationTrack circuit for DC power feeding railway
Design StandardKRS SG 0035-07(R), KS C 3101, 3103, 3004
ConstructionItem DescriptionConductor Annealed stranded copper wireInsulation PE
Filler PVC or non-fibroid materialShield Annealed copper tapeSheath Flame retardant PVC
Item Value
Conductor Resistance 9.42 /km
Insulation Resistance 3500 M
Capacitance 52 nF/km 1KHz
Room Temp.Yield 9.81 N/mm2
PE InsulationElongation 350%
After HeatingYield 85%
Elongation 65%
Room Temp.Yield 9.81 N/mm2
PVC SheathElongation 120%
After HeatingYield 85%
Elongation 65%
Yield Strength and
Elongation
PVC Oil ResistanceYield 80%
Elongation 60%
Deformation After HeatInsulation 10%
Sheath 50%
Yield 257 N/mm2
Annealed Copper Tape Elongation 5%
Conductivity 97%
Item Unit Application
Cross Section mm2 2
Conductor Construction No / mm 7 / 0.6
Diameter mm 1.8
Insulation Thickness mm 1.8
Insulation Diameter mm 5.4
Stranding Diameter mm 10.9
Copper Tape Thickness mm About 0.1
Sheath Thickness mm 1.5
Cable Diameter mm 14.64
Max. Conductor Resistance / km (20 ) 9.42
Min. Insulation Resistance M . km (20 ) 3500
Between Conductors kV / min 6 / 1Voltage Test Between Conductor
kV / min 6 / 1And Shield
Package Length m 800
Capacitance nF / km (1MHz) 52
Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling AF Track Circuit Cable(DC) F-SUIREE-S5
ApplicationCable for AF track circuit
Design StandardKS C 3004/2002: Testing methods for rubber or plastic insulated wires and cablesIEC 60228: Conductors of insulated cablesIEC 60754-1: Test on gases evolved during combustion of materials part IASTM D 2863: Standard test Method for measuring the minimum oxygen concentration to support candle-like combustion of plastics (Oxygen Index)IEC 61034: Measurement of Smoke density of electric cable burning under defined
ConditionsIEC 60332-3-24: Tests onelectric cables under fire conditions-part 3-24: Test for vertical flame spread of vertically-mounted bunched wiresor cables-category
Construction
CombinationEach paired wire string shall be uniformly twisted with S-type direction. and then, wind Polyester tape on the combination layer. If necessary, put appropriate inclusions into the layer so that the original form of cable can be maintained.
ShieldingOverlap and wind bedding layer with 0.1mm-thick copper tape. And then, wind it with binder tape.
JacketUse fire-proof halogen free material with low toxicity and low smoke to coat jacket concentrically and uniformly. The average thick-ness of jacket shall be over 90% of the value in index table and the minimum value over 80%.jacket color is black.
RailsolTM_Xcel AF Track Circuit Cable(DC)
F-SUIREE-S
Conductor Tin plated soft drawn copper wire (IEC 60228)Insulation Low toxicity and irradiation cross-linked polyethylene (XLPE)Twisted Pair Assembly Each pairs shall be uniformly stranded with S-directionBinder Polyester tapeShield Copper tape (0.1mm)Sheath Halogen free / Flame retardant / Low toxicity / Low smoke (BK)
Color Pair TableClassification 1 Core 2 Core1 Pair White Black2 Pair White Black
White Red4 Pair White Black
White RedWhite GreenWhite Yellow
-
RailsolTM_Xcel AF Track Circuit Cable (AC)
ApplicationTrack circuit for AC power feeding railway
Design StandardKRS SG 0034-07(R), KS C 3101, 3103, 3004
Construction PE Insulation, copper tape, metal corrugated sheath or copper wire sheath, steel tape armour
Conductor Diameter 1.2 mm
Insulation Thickness 0.6 mm
QuadCenter 1 2 3 4 5 1 2 4
First Layer - - - - - 6 8 10
ShieldThickness 0.4 0.4 0.4 0.4 0.5 0.5 0.6 0.6
Outer Diameter 17 23 24 26 28 32 37 45
2P 4P 6P 8P 10P 14P 20P 28P
Item MaterialConductor KSC 3101Insulation PEInsulation Layer Composed of inner polyethylene sheath, plastic tape, kraft paper, metalized paper etcShield Copper tape, copper wireSheath Polyethylene Tape CottonArmour Double steel tape or single layer galvanized steel wire armourJacket Polyethylene
Copper Tape Shield Cable
Conductor Diameter 1.2 mm
Insulation Thickness 0.6 mm
QuadCenter 1 2 3 4 5 1 2 4
First Layer - - - - - 6 8 10
ShieldThickness 1.2 1.2 1.2 1.2 1.3 1.3 1.4 1.4
Outer Diameter 8 13 16 19 20 22 26 29
2P 4P 6P 8P 10P 14P 20P 28P
Other dimensions available on enquiry
Copper Wire Shield Cable
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling AF Track Circuit Cable (AC) 6
-
ApplicationTrack Circuit Cable ( ~ 30KHz)
Construction Technical Data Conductor 1.4 mm (0.6 mm for the auxiliary pair)
Insulation PE
Twisted pair, pairs are helically stranded
Core Wrapping Plastic tapes with overlapping
Inner Sheath LDPEMoisture Barrier One copolymer coated laminated
aluminum tape
Intermediate Sheath Halogen free (Indoor), LDPE (Outdoor)Mechanical Protection Double steel type or single layer
galvanized steel wire armour
Outer Sheath Halogen free (Indoor), PVC (Outdoor)
Properties
RailsolTM_Xcel Digicode Cable
Voltage 220 V
Operation Temp. -10 ~ +50
Max. Capacity Pair/Core to Core 45 nF/km
Capacitance Unbalance (Pair-Pair) 400 pF/500m
Capacitance Unbalance (Pair-Ground) 1500 pF/500m
DC Conductor Resistance 12.1 /km
Ampacity 1ABending Factor 20 x D
1 1.4 0,7 1,3 1,5 17,9 428
2 1.4 0,7 1,3 1,5 19,2 497
3 1.4 0,7 1,3 1,5 20,2 562
Cond. Diamete Nominal Sheath Thickness (mm) Nominal Outer Diameter Nominal WeightNo.of Pair
(mm) (mm) (kg / km)Inner Inerm. Outer
Indoor
Outdoor
1 1.4 0,7 1,3 1,5 17,9 395
2 1.4 0,7 1,3 1,5 19,2 461
3 1.4 0,7 1,3 1,5 20,2 521
Cond. Diameter Nominal Sheath Thickness (mm) Nominal Outer Diameter Nominal WeightNo.of Pair
(mm) (mm) (kg / km)Inner Inerm. Outer
Other dimensions available on enquiry
RailsolTM_Xcel Signaling Digicode Cable7
-
Control CableRailsolTM Xcel ZPAU 8
RailsolTM_Xcel Signaling
RailsolTM_Xcel ZC03
RailsolTM_Xcel Signaling ZC03 8
ApplicationConnect between terminal box and rack (Max. 7km)Long distance telecommunication side by line (25 kVac)Connect between transportation control center and machine room
Design StandardSNCF CT 445 (NF F 55-698)
Construction Technical Data Conductor Class 1 solid copper conductor
Insulation PE
Construction Twisted quad
Core Wrapping Plastic tape with overlapping
Inner Sheath Halogen free PE
Shield Corrugated copper shield
Intermediate Sheath Halogen free PE
Outer Wrapping Double steel Tape
Outer Sheath Halogen free (Indoor), PVC (Outdoor)
Voltage 750 V
Operation Temp. -25 ~ +70
Capacitance Max. 40 nF/km
DC Conductor Resistance Max. 18.1 /km
Reduction Factor 150 V/km Max. 0.14
Min. Bending Radius 8D (Static), 16D (Dynamic)
4 1 1 / 1.12 2.5 26.1 1281
No.of QuadCross Section Construction Insulated Core Overall Diameter Net Weight
(mm2) (No / mm) (mm) (mm) (kg / km)
Other dimensions available on enquiry
-
RailsolTM_Xcel ZPFU
RailsolTM_Xcel Signaling ZPFU9
ApplicationConnect between terminal box and matching transformer (2-pair ZPFU)Long distance telecommunication side by line (1500 Vdc)Short distance telecommuinication side by line (25 kVac)
Design StandardSNCF CT 445 (NF F 55-698)
Construction Technical Data Voltage 750 V
Operation Temp. -25 ~ +70
Capacitance Max. 55 nF/km
DC Conductor Resistance Max. 18.1 /km
Impedance 120 45 KHz
Attenuation Max. 2.5 dB/km 45 KHz
Min. Bending Radius 8D (Static), 16D (Dynamic)
Conductor Class1 solid copper conductor
Insulation PE
Construction Twisted pair
Core Wrapping Plastic tape with overlapping
Inner Sheath Halogen free PE
Outer Wrapping Double steel Tape
Outer Sheath Halogen free (Indoor), PVC (Outdoor)
1 1 1 / 1.12 2.15 11.4 158
2 1 1 / 1.12 2.15 12.6 218
4 1 1 / 1.12 2.15 16.0 330
7 1 1 / 1.12 2.15 19.5 615
14 1 1 / 1.12 2.15 24.5 945
21 1 1 / 1.12 2.15 28.1 1216
28 1 1 / 1.12 2.15 32.1 1439
No.of PairCopper Area Construction Insulated Core Overall Diameter Net Weight
(mm2) (No / mm) (mm) (mm) (kg / km)
Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel ZPAU
ApplicationShort distance telecommunicaiton side by line (25 kVac)Connect between transport control center and machine room
Design StandardSNCF CT 445 (NF F 55-698)
Construction Technical Data Conductor Class1 solid copper conductor
Insulation PE
Construction Twisted pair
Core Wrapping Plastic tape with overlapping
Inner Sheath Halogen free PE
Shield Corrugated copper shield
Intermediate Sheath Halogen free PE
Outer Wrapping Double steel tape
Outer Sheath Halogen free (Indoor), PVC (Outdoor)
Voltage 750 V
Operation Temp. -25 ~ +70
Capacitance Max. 55 /km
DC Conductor Resistance Max. 18.1 /km
Impedance 120 45 KHz
Attenuation Max. 2.5 dB/km 45 KHz
Min. Bending Radius 8D (Static), 16D (Dynamic)
4 1 1 / 1.12 2.15 19.6 625
7 1 1 / 1.12 2.15 22.5 805
14 1 1 / 1.12 2.15 27.1 1122
21 1 1 / 1.12 2.15 32.0 1496
28 1 1 / 1.12 2.15 34.4 1755
56 1 1 / 1.12 2.15 49.5 2991
No.of PairCopper Area Construction Insulated Core Overall Diameter Net Weight
(mm2) (No / mm) (mm) (mm) (kg / km)
ZPAU 10RailsolTM_Xcel Signaling 10
Other dimensions available on enquiry
-
RailsolTM_Xcel ZUG/SUG/ZUT
RailsolTM_Xcel Signaling ZUG/SUG/ZUT11
ApplicationConnect the control terminal rack to PEU or electronic equipment
Design StandardSNCF CT 455
Construction Technical Data Conductor Class5 stranded tinned copper
Insulation Colored PVC
Shield Tinned Copper braid (ZUT)
Sheath Halogen free (Indoor), PVC (Outdoor)
Twisted Pair (ZUG/ZUT) or Conductor (SUG)
Laid in a Cable Tray
Voltage 750 V
Operation Temp. -25 ~ +70
Capacitance Max. 55 nF/km
DC Conductor Resistance 1mm2, Max. 18.1 /km,0.38mm2, Max. 52.5 /km
Impedance 120 45 KHz
Attenuation Max. 2.5 dB/km 45 KHz
Min. Bending Radius 4D (Static), 8D (Dynamic)
1 1 32 / 0.2 2.09 6.9 61
3 1 32 / 0.2 2.09 10.0 116
6 1 32 / 0.2 2.09 14.0 223
12 1 32 / 0.2 2.09 15.7 340
28 0.38 12 / 0.2 1.04 15.4 331
No.of PairCond. Cross Section Construction Insulated Core Overall Diameter Net Weight
(mm2) (No / mm) (mm) (mm) (kg / km)
Multi-Pair ZUG
3 1 32 / 0.2 2.09 8 73
No.of PairCond. Cross Section Construction Insulated Core Overall Diameter Net Weight
(mm2) (No / mm) (mm) (mm) (kg / km)
Multi-Conductors SUG
2 1 32 / 0.2 2.09 9.5 122
6 1 32 / 0.2 2.09 13.5 276
12 1 32 / 0.2 2.09 17.5 445
No.of PairCond. Cross Section Construction Insulated Core Overall Diameter Net Weight
(mm2) (No / mm) (mm) (mm) (kg / km)
Multi-Pair ZUT
Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling 0.6/1kV F-CV 12
ApplicationType flame-retardant cable is used for power and lighting circuits in tray, undergroundduct and open air in accordance with technical standard for electrical equipments
Design standardIEC 60502-1
Flammability Vertical tray flame test (VTFT) to IEC 60332-3-24 cat.C
RailsolTM_Xcel 0.6/1kV F-CV
1.5 7/0.53 1.59 0.7 1.4 6.3 12.1 3.5 502.5 7/0.67 2.01 0.7 1.4 6.7 7.41 3.5 704 7/0.85 2.55 0.7 1.4 7.2 4.61 3.5 906 7/1.04 3.12 0.7 1.4 7.8 3.08 3.5 11010 7/1.35 4.05 0.7 1.4 9.4 1.83 3.5 17016 4.7 0.7 1.4 10.0 1.15 3.5 21025 5.9 0.9 1.4 12.0 0.727 3.5 31035 6.9 0.9 1.4 13.0 0.524 3.5 40050 8.1 1.0 1.4 14.5 0.387 3.5 52070 9.8 1.1 1.4 16.0 0.268 3.5 72095 11.4 1.1 1.5 18.5 0.193 3.5 970120 12.9 1.2 1.5 20 0.153 3.5 1,210150 14.4 1.4 1.6 22 0.124 3.5 1,490185 15.9 1.6 1.6 24 0.0991 3.5 1,840240 18.3 1.7 1.7 27 0.0754 3.5 2,400300 20.5 1.8 1.8 30 0.0601 3.5 2,980400 23.2 2.0 1.9 34 0.0470 3.5 3,800500 26.4 2.2 2.0 37 0.0366 3.5 4,850630 30.2 2.4 2.2 42 0.0283 3.5 6,240
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (Single Core)
InsulationThickness
Approx. Overall Diameter
(mm)(mm)
Core Identification
ConstructionConductor Compacted or circular stranded annealed copper class 2Insulation 90 Cross-linked polyethylene (XLPE)Assembly Multi-cores of cable shall be assembled to form a circular cableSheath Black flame retardant PVC (FR-PVC)
Compacted Circular / Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling 0.6/1kV F-CV13
1.5 7/0.53 1.59 0.7 1.8 11.0 12.1 3.5 1202.5 7/0.67 2.01 0.7 1.8 12.0 7.41 3.5 1504 7/0.85 2.55 0.7 1.8 13.0 4.61 3.5 1906 7/1.04 3.12 0.7 1.8 14.0 3.08 3.5 24010 7/1.35 4.05 0.7 1.8 17.0 1.83 3.5 33016 4.7 0.7 1.8 18.5 1.15 3.5 45025 5.9 0.9 1.8 22 0.727 3.5 66035 6.9 0.9 1.8 24 0.524 3.5 88050 8.1 1.0 1.8 27 0.387 3.5 1,15070 9.8 1.1 1.8 31 0.268 3.5 1,61095 11.4 1.1 1.9 35 0.193 3.5 2,170120 12.9 1.2 2.0 38 0.153 3.5 2,670150 14.4 1.4 2.2 43 0.124 3.5 3,310185 15.9 1.6 2.3 47 0.0991 3.5 4,110240 18.3 1.7 2.5 53 0.0754 3.5 5,340300 20.5 1.8 2.6 58 0.0601 3.5 6,630
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (2 Core)
InsulationThickness
Approx.Overall Diameter
(mm)(mm)
1.5 7/0.53 1.59 0.7 1.8 11.5 12.1 3.5 150
2.5 7/0.67 2.01 0.7 1.8 12.5 7.41 3.5 180
4 7/0.85 2.55 0.7 1.8 13.5 4.61 3.5 240
6 7/1.04 3.12 0.7 1.8 14.5 3.08 3.5 310
10 7/1.35 4.05 0.7 1.8 18.0 1.83 3.5 450
16 4.7 0.7 1.8 19.5 1.15 3.5 610
25 5.9 0.9 1.8 23 0.727 3.5 900
35 6.9 0.9 1.8 25 0.524 3.5 1,210
50 8.1 1.0 1.8 29 0.387 3.5 1,560
70 9.8 1.1 1.9 33 0.268 3.5 2,200
95 11.4 1.1 2.0 37 0.193 3.5 2,970
120 12.9 1.2 2.1 41 0.153 3.5 3,790
150 14.4 1.4 2.3 46 0.124 3.5 4,670
185 15.9 1.6 2.4 50 0.0991 3.5 5,830
240 18.3 1.7 2.6 57 0.0754 3.5 7,580
300 20.5 1.8 2.7 62 0.0601 3.5 9,400
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (3 Core)
InsulationThickness
Approx.Overall Diameter
(mm)(mm)
1.5 7/0.53 1.59 0.7 1.8 12.5 12.1 3.5 170
2.5 7/0.67 2.01 0.7 1.8 13.5 7.41 3.5 220
4 7/0.85 2.55 0.7 1.8 14.5 4.61 3.5 290
6 7/1.04 3.12 0.7 1.8 16.0 3.08 3.5 380
10 7/1.35 4.05 0.7 1.8 20 1.83 3.5 570
16 4.7 0.7 1.8 22 1.15 3.5 790
25 5.9 0.9 1.8 26 0.727 3.5 1,180
35 6.9 0.9 1.8 28 0.524 3.5 1,550
50 8.1 1.0 1.9 32 0.387 3.5 2,060
70 9.8 1.1 2.0 36 0.268 3.5 2,930
95 11.4 1.1 2.1 42 0.193 3.5 3,970
120 12.9 1.2 2.3 46 0.153 3.5 4,980
150 14.4 1.4 2.4 51 0.124 3.5 6,130
185 15.9 1.6 2.6 56 0.0991 3.5 7,660
240 18.3 1.7 2.8 63 0.0754 3.5 9,960
300 20.5 1.8 3.0 70 0.0601 3.5 12,380
Nominal Cross Section Construction
(mm2) (No / mm)
Diameter
(mm) ( / km) (kg / km)
Conductor
(mm)
SheathThickness
Approx.Weight
(kV)
Test Voltage
D.C ConductorResistance(20 )
0.6 / 1kV F-CV (4 Core)
InsulationThickness
Approx.Overall Diameter
(mm)(mm)
Compacted Circular / Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling 0.6 / 1kV F-CVV 14
RailsolTM_Xcel 0.6 / 1kV F-CVV
ConstructionConductor Stranded annealed copper class 2Insulation PVC (70 )Assembly Multi-cores of cable shall be assembled to form a circular cableSheath Flame retardant PVC (FR-PVC)
Core identification2 cores Black, white 3 cores Black, white, red4 cores Black, white, red, greenMore than Numbering
Other dimensions available on enquiry
ApplicationType F-CVV is used for control circuits in underground duct, conduit and open air
Design StandardIEC 60502-1 : Power cables with extruded insulation and their accessories for rated voltages
from 1kV (Um=1.2kV) up to 3kV (Um=36kV)Part1 : Cables for rated voltages of 1kV (Um=1.2kV) and 3kV (Um=3.6kV)
1.5 7/0.53 1.59 11.0 12.1 150
2.5 7/0.67 2.01 12.0 7.41 190
4 7/0.85 2.55 14.0 4.61 3.5 250
6 7/1.04 3.12 15.0 3.08 310
10 7/1.35 4.05 17.0 1.83 420
1.5 7/0.53 1.59 11.5 12.1 190
2.5 7/0.67 2.01 12.5 7.41 230
4 7/0.85 2.55 14.5 4.61 3.5 320
6 7/1.04 3.12 16.0 3.08 410
10 7/1.35 4.05 18.0 1.83 560
1.5 7/0.53 1.59 12.5 12.1 230
2.5 7/0.67 2.01 13.5 7.41 280
4 7/0.85 2.55 16.0 4.61 3.5 400
6 7/1.04 3.12 17.0 3.08 510
10 7/1.35 4.05 19.5 1.83 710
1.5 7/0.53 1.59 13.5 12.1 270
2.5 7/0.67 2.01 14.5 7.41 340
4 7/0.85 2.55 17.0 4.61 3.5 490
6 7/1.04 3.12 18.5 3.08 620
10 7/1.35 4.05 21.0 1.83 870
0.6/1kV F-CVV
0.8
1.0
0.8
1.0
0.8
1.0
0.8
1.0
2
3
4
5
1.8
1.8
1.8
1.8
3.5
3.5
3.5
3.5
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
No. ofcores
-
RailsolTM_Xcel Signaling 0.6 / 1kV F-CVV15
1.5 7/0.53 1.59 0.8 14.5 12.1 310
2.5 7/0.67 2.01 15.5 7.41 390
6 4 7/0.85 2.55 1.8 18.5 4.61 3.5 570
6 7/1.04 3.12 1.0 21.0 3.08 730
10 7/1.35 4.05 23.0 1.83 1020
1.5 7/0.53 1.59 0.8 14.5 12.1 330
2.5 7/0.67 2.01 15.5 7.41 420
7 4 7/0.85 2.55 1.8 18.5 4.61 3.5 620
6 7/1.04 3.12 1.0 21.0 3.08 800
10 7/1.35 4.05 23.0 1.83 1140
1.5 7/0.53 1.59 0.8 15.5 12.1 380
2.5 7/0.67 2.01 16.5 7.41 490
8 4 7/0.85 2.55 1.8 20.0 4.61 3.5 720
6 7/1.04 3.12 1.0 22.0 3.08 920
10 7/1.35 4.05 25.0 1.83 1310
1.5 7/0.53 1.59 0.8 18.0 12.1 460
2.5 7/0.67 2.01 19.5 7.41 590
10 4 7/0.85 2.55 1.8 23.0 4.61 3.5 870
6 7/1.04 3.12 1.0 26.0 3.08 1130
10 7/1.35 4.05 29.0 1.83 1610
1.5 7/0.53 1.59 0.8 18.5 12.1 530
2.5 7/0.67 2.01 20.0 7.41 680
12 4 7/0.85 2.55 1.8 24.0 4.61 3.5 1020
6 7/1.04 3.12 1.0 27.0 3.08 1320
10 7/1.35 4.05 30.0 1.83 1890
1.5 7/0.53 1.59 0.8 19.5 12.1 630
15 2.5 7/0.67 2.01 1.8 22.0 7.41 3.5 830
4 7/0.85 2.55 1.0 26.0 4.61 1240
6 7/1.04 3.12 29.0 3.08 1620
1.5 7/0.53 1.59 0.8 22.0 12.1 810
20 2.5 7/0.67 2.01 1.8 24.0 7.41 3.5 1060
4 7/0.85 2.55 1.0 29.0 4.61 1610
6 7/1.04 3.12 32.0 3.08 2100
1.5 7/0.53 1.59 0.8 1.8 26.0 12.1 1150
30 2.5 7/0.67 2.01 28.0 7.41 3.5 1520
4 7/0.85 2.55 1.0 1.9 35.0 4.61 2350
0.6/1kV F-CVV
0.8
1.0
0.8
1.0
0.8
1.0
0.8
1.0
6
7
8
12
15
30
20
10
1.8
1.8
1.8
1.8
1.8
0.8
1.0
1.8
0.8
1.01.8
0.8
1.01.8
0.81.8
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
Other dimensions available on enquiry
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
No. ofcores
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling 0.6 / 1kV F-CVV-S, 0.6 / 1kV F-CVV-SB 16
ApplicationType F-CVV-S, F-CVV-SB is used for control circuits in underground duct, conduit and open air.
Design StandardIEC 60502-1
Construction
RailsolTM_Xcel 0.6 / 1kV F-CVV-S, 0.6 / 1kV F-CVV-SB
0.6 / 1kV F-CVV-S, 0.6 / 1kV F-CVV-SB
Core Identification
Conductor Stranded annealed copper class 2Insulation PVC(70 )Assembly Multi cores of cable shall be assembled to form a circular cableShield The copper tape or copper braid shield is applied helically around the assembled cable coresSheath Black flame returdant PVC(FR-PVC)
Other dimensions available on enquiry
1.5 7/0.53 1.59 11.0 12.1 150
2.5 7/0.67 2.01 12.0 7.41 190
4 7/0.85 2.55 14.0 4.61 3.5 250
6 7/1.04 3.12 15.0 3.08 310
10 7/1.35 4.05 17.0 1.83 420
1.5 7/0.53 1.59 11.5 12.1 190
2.5 7/0.67 2.01 12.5 7.41 230
4 7/0.85 2.55 14.5 4.61 3.5 320
6 7/1.04 3.12 16.0 3.08 410
10 7/1.35 4.05 18.0 1.83 560
1.5 7/0.53 1.59 12.5 12.1 230
2.5 7/0.67 2.01 13.5 7.41 280
4 7/0.85 2.55 16.0 4.61 3.5 400
6 7/1.04 3.12 17.0 3.08 510
10 7/1.35 4.05 19.5 1.83 710
1.5 7/0.53 1.59 13.5 12.1 270
2.5 7/0.67 2.01 14.5 7.41 340
4 7/0.85 2.55 17.0 4.61 3.5 490
6 7/1.04 3.12 18.5 3.08 620
10 7/1.35 4.05 21.0 1.83 870
0.8
1.0
0.8
1.0
0.8
1.0
0.8
1.0
2
3
4
5
1.8
1.8
1.8
1.8
3.5
3.5
3.5
3.5
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
No. ofcores
-
RailsolTM_Xcel Signaling 0.6 / 1kV F-CVV-S, 0.6 / 1kV F-CVV-SB17
0.6 / 1kV F-CVV-S, 0.6 / 1kV F-CVV-SB
1.5 7/0.53 1.59 0.8 14.5 12.1 310
2.5 7/0.67 2.01 15.5 7.41 390
6 4 7/0.85 2.55 1.8 18.5 4.61 3.5 570
6 7/1.04 3.12 1.0 21.0 3.08 730
10 7/1.35 4.05 23.0 1.83 1020
1.5 7/0.53 1.59 0.8 14.5 12.1 330
2.5 7/0.67 2.01 15.5 7.41 420
7 4 7/0.85 2.55 1.8 18.5 4.61 3.5 620
6 7/1.04 3.12 1.0 21.0 3.08 800
10 7/1.35 4.05 23.0 1.83 1140
1.5 7/0.53 1.59 0.8 15.5 12.1 380
2.5 7/0.67 2.01 16.5 7.41 490
8 4 7/0.85 2.55 1.8 20.0 4.61 3.5 720
6 7/1.04 3.12 1.0 22.0 3.08 920
10 7/1.35 4.05 25.0 1.83 1310
1.5 7/0.53 1.59 0.8 18.0 12.1 460
2.5 7/0.67 2.01 19.5 7.41 590
10 4 7/0.85 2.55 1.8 23.0 4.61 3.5 870
6 7/1.04 3.12 1.0 26.0 3.08 1130
10 7/1.35 4.05 29.0 1.83 1610
1.5 7/0.53 1.59 0.8 18.5 12.1 530
2.5 7/0.67 2.01 20.0 7.41 680
12 4 7/0.85 2.55 1.8 24.0 4.61 3.5 1020
6 7/1.04 3.12 1.0 27.0 3.08 1320
10 7/1.35 4.05 30.0 1.83 1890
1.5 7/0.53 1.59 0.8 19.5 12.1 630
15 2.5 7/0.67 2.01 1.8 22.0 7.41 3.5 830
4 7/0.85 2.55 1.0 26.0 4.61 1240
6 7/1.04 3.12 29.0 3.08 1620
1.5 7/0.53 1.59 0.8 22.0 12.1 810
20 2.5 7/0.67 2.01 1.8 24.0 7.41 3.5 1060
4 7/0.85 2.55 1.0 29.0 4.61 1610
6 7/1.04 3.12 32.0 3.08 2100
1.5 7/0.53 1.59 0.8 1.8 26.0 12.1 1150
30 2.5 7/0.67 2.01 28.0 7.41 3.5 1520
4 7/0.85 2.55 1.0 1.9 35.0 4.61 2350
0.8
1.0
0.8
1.0
0.8
1.0
0.8
1.0
6
7
8
12
15
30
20
10
1.8
1.8
1.8
1.8
1.8
0.8
1.0
1.8
0.8
1.01.8
0.8
1.01.8
0.81.8
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
Other dimensions available on enquiry
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
No. ofcores
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling 0.6 / 1kV F-FR-8 18
RailsolTM_Xcel 0.6 / 1kV F-FR-8
Other dimensions available on enquiry
ApplicationF-FR-8 used for residential and commercial buildings and industrial fire proof distribution circuits
Design StandardIEC 60502-1
1.5 7 / 0.53 1.59 8.5 12.1 60
2.5 7 / 0.67 2.01 9.0 7.41 80
4 7 / 0.85 2.55 0.7 9.5 4.61 100
6 7 / 1.04 3.12 10.0 3.08 120
10 7 / 1.35 4.05 1.4 11.0 1.83 180
16 4.7 12.0 1.15 220
25 5.9 0.9 13.5 0.727 320
35 6.9 15.0 0.524 430
50 8.1 1.0 16.5 0.387 540
70 9.8 1.1 1.5 18.5 0.268 3.5 740
95 11.4 20.5 0.193 990
120 ø¯«¸æ–√‡ø¨º± 12.9 1.2 1.6 22.5 0.153 1230
150 14.4 1.4 1.7 25.0 0.124 1530
185 15.9 1.6 27.0 0.0991 1890
240 18.3 1.7 1.8 30.0 0.0754 2450
300 20.5 1.8 1.9 33.0 0.0601 3040
400 23.2 2.0 2.0 36.5 0.0470 3860
500 26.4 2.2 2.1 41.0 0.0366 4920
630 30.2 2.4 2.3 46.0 0.0283 6320
0.6/1kV F-FR-8 (Single Core)
3.5
1.7
1.5
1.4
0.7
0.9
1.1
Compacted
Circular
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
ConstructionConductor Compacted or circular stranded annealed copper class 2Fire-Proof Layer Mica tapeInsulation Cross linked polyethylene (XLPE)Assembly Multi cores of cable shall be assembled to form a circular cableSheath Black flame retardant PVC (FR-PVC)
Core identification1 core (XLPE)2 cores Black, white 3 cores Black, white, red4 cores Black, white, red, green
-
Other dimensions available on enquiry
1.5 7 / 0.53 1.59 14.0 12.1 1302.5 7 / 0.67 2.01 15.0 7.41 1704 7 / 0.85 2.55 0.7 16.0 4.61 2106 7 / 1.04 3.12 17.5 3.08 26010 7 / 1.35 4.05 1.8 19.5 1.83 35016 4.7 21.0 1.15 47025 5.9 0.9 24.5 0.727 68035 6.9 26.5 0.524 3.5 91050 8.1 1.0 30.0 0.387 118070 9.8 1.1 1.9 34.5 0.268 164095 ø¯«¸æ–√‡ø¨º± 11.4 1.1 2.0 38.0 0.193 2210120 12.9 1.2 2.2 42.0 0.153 2710150 14.4 1.4 2.3 46.5 0.124 3390185 15.9 1.6 2.4 51.0 0.0991 4200240 18.3 1.7 2.6 57.5 0.0754 5440300 20.5 1.8 2.8 63.0 0.0601 6740
0.6/1kV F-FR-8 (2 Cores)
3.5
1.8
0.7
0.9
1.1Compacted
Circular
1.5 7 / 0.53 1.59 15.0 12.1 1702.5 7 / 0.67 2.01 16.0 7.41 2004 7 / 0.85 2.55 0.7 17.0 4.61 2706 7 / 1.04 3.12 1.8 18.5 3.08 34010 7 / 1.35 4.05 20.5 1.83 47016 4.7 22.0 1.15 64025 5.9 0.9 26.0 0.727 93035 6.9 28.5 0.524 3.5 125050 8.1 1.0 1.9 32.0 0.387 160070 ø¯«¸æ–√‡ø¨º± 9.8 1.1 2.0 37.0 0.268 224095 11.4 2.1 41.0 0.193 3020120 12.9 1.2 2.3 45.5 0.153 3850150 14.4 1.4 2.4 50.5 0.124 4790185 15.9 1.6 2.6 55.5 0.0991 5960240 18.3 1.7 2.8 62.0 0.0754 7730300 20.5 1.8 2.9 68.0 0.0601 9570
0.6/1kV F-FR-8 (3 Cores)
3.5
1.8
0.7
0.9
1.1Compacted
Circular
1.5 7 / 0.53 1.59 16.0 12.1 1902.5 7 / 0.67 2.01 17.0 7.41 2504 7 / 0.85 2.55 0.7 18.5 4.61 3306 7 / 1.04 3.12 1.8 20.0 3.08 42010 7 / 1.35 4.05 22.5 1.83 60016 4.7 24.5 1.15 82025 5.9 0.9 28.5 0.727 122035 6.9 31.5 0.524 3.5 160050 8.1 1.0 2.0 35.5 0.387 211070 9.8 1.1 2.1 41.0 0.268 299095 ø¯«¸æ–√‡ø¨º± 11.4 2.3 45.5 0.193 4040120 12.9 1.2 2.4 50.5 0.153 5050150 14.4 1.4 2.6 56.0 0.124 6280185 15.9 1.6 2.7 61.5 0.0991 7830240 18.3 1.7 3.0 69.0 0.0754 10160300 20.5 1.8 3.2 76.0 0.0601 12600
0.6/1kV F-FR-8 (4 Cores)
1.8
0.7
0.9
1.1Compacted
Circular
3.5
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
Conductor Insulation Sheath Approx. Conductor Test Approx.Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
RailsolTM_Xcel Signaling 0.6 / 1kV F-FR-819
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling 450 / 750V KIV 20
ApplicationType KIV is suitable for wiring on panel boards, switchboards and control apparatus at max conductortemperature at 70
Design StandardKS C 3325, IEC 60227-3
450 / 750V KIV
RailsolTM_Xcel 450 / 750V KIV
Conductor Flexible stranded annealed copper
Insulation Abrasion and moisture-resistant PVC
1.5 1.6 0.7 2.8 3.4 13.3 13.7 0.010 30
2.5 2.1 0.8 3.4 4.1 7.98 8.21 0.009 40
4 2.6 0.8 3.9 4.8 4.95 5.09 0.007 50
6 3.6 0.8 4.4 5.3 3.30 3.39 0.006 80
10 4.8 1.0 5.7 6.8 1.91 1.95 0.0056 130
16 6.0 1.0 6.7 8.1 1.21 1.24 0.0046 180
25 7.4 1.2 8.4 10.2 0.780 0.795 0.0044 280
35 8.7 1.2 9.7 11.7 0.554 0.565 0.0038 370
50 10.4 1.4 11.5 13.9 0.386 0.393 0.0037 500
70 12.5 1.4 13.2 16.0 0.272 0.277 0.0032 700
95 14.5 1.6 15.1 18.2 0.206 0.210 0.0032 970
120 16.2 1.6 16.7 20.2 0.161 0.164 0.0029 1,200
150 18.2 1.8 18.6 22.5 0.129 0.132 0.0029 1,490
185 20.2 2.0 20.6 24.9 0.106 0.108 0.0029 1,850
240 23.3 2.2 23.5 28.4 0.0801 0.0817 0.0028 2,440
Construction
Conductor Approx. Overall Diameter
Cross Section
(mm2)
InsulationThickness
(mm)
InsulationResistance
(70 )(M . km)
Approx. Weight
( kg / km)
Diameter
(mm)
Minimum
(mm)
Maximum
(mm)
Conductor Resistance(20 )
Non Plated
( / km)
Plated
( / km)
Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling K2321
RailsolTM_Xcel K23
ApplicationCity railway communication network (remote control)Use for electric railway under 1500 Vdc
Design StandardNF F 55-623
Construction Technical Data Conductor Solid copper core
Insulation Colored PE
Construction Star quad
Shield Al-PE tape with drain wire
Inner Sheath Halogen free watertight
Outer Wrapping Double steel tape
Outer Sheath Halogen free (Indoor), PVC (Outdoor)
Voltage 150V, 500V, 750V (Conductor : 0.6, 1.0, 1.2 mm)
Operation Temp. -25 ~ +60
Min. Bending Radius 8D (Static), 16D (Dynamic)
2 0.9 9.7 146
4 0.9 10.3 177
8 0.9 11.8 234
14 0.9 13.4 303
20 0.9 14.5 366
28 0.9 16.6 461
38 0.9 17.9 555
56 0.9 21.1 729
No.of QuadInsulated Core Overall Diameter Net Weight
(mm) (mm) (kg / km)
Conductor : 0.6mm
2 1.8 10.9 198
4 1.8 14.1 305
8 1.8 17.3 453
14 1.8 19.5 602
20 1.8 22.4 782
28 1.8 25.4 1007
38 1.8 29.3 1285
56 1.8 34.2 1740
84 1.8 43.1 2480
112 1.8 50.9 3170
No.of QuadInsulated Core Overall Diameter Net Weight
(mm) (mm) (kg / km)
Conductor : 1.0mm
Conductor Diameter (mm)
0.6 1.0 1.2
64 23 16
Conductor Diameter (mm)1 Pair 4 Pair Others
67 62 57.5
1 2.0 11.0 195
2 2.0 11.8 238
4 2.0 15.4 371
8 2.0 18.4 536
14 2.0 20.9 738
20 2.0 24.3 986
28 2.0 27.4 1258
No.of QuadInsulated Core Overall Diameter Net Weight
(mm) (mm) (kg / km)
Conductor : 1.2mm
DC Conductor Resistance( / km), Max.
Capacitance (nF/km), Max.
Other dimensions available on enquiry
-
RailsolTM_Xcel Signaling
RailsolTM_Xcel Signaling 0.6 / 1kV F-GV 22
ApplicationType F-GV is used for grounding wire
Design StandardIEC 60502-1
RailsolTM_Xcel 0.6 / 1kV F-GV
0.6 / 1kV F-GV
ConstructionConductor Solid or stranded or compacted stranded annealed copper class 2Insulation Abrasion and moisture-resistant FR-PVC
1.5 7 / 0.53 1.59 6.5 12.1 60
2.5 7 / 0.67 2.01 7.0 7.41 80
4 7 / 0.85 2.55 8.0 4.61 110
6 7 / 1.04 3.12 8.5 3.08 130
10 7 / 1.35 4.05 9.5 1.83 180
16 4.7 10.0 1.15 230
25 5.9 12.0 0.727 340
35 6.9 13.0 0.524 440
50 8.1 14.5 0.387 570
70 9.8 16.0 0.268 780
95 11.4 18.5 0.193 1060
120 12.9 20 0.153 130
150 14.4 3.4 22 0.124 1600
185 15.9 3.7 25 0.0991 1980
240 18.3 4.0 28 0.0754 2580
300 20.5 4.3 30 0.0601 3210
400 23.2 4.6 34 0.0470 4050
500 26.4 4.9 38 0.0366 5150
630 30.2 5.0 42 0.0283 6570
Other dimensions available on enquiry
3.5
2.2
2.4
2.6
2.8
3.1Compacted
Circular
Conductor Insulation Overall Conductor Test Approx.Nominal Cross Section Construction Outer Diameter Thickness Diameter Resistance(20 ) Volta