media kit 2022 - can-cia.org

14
CAN in Automation GmbH Media kit 2022 CAN Newsletter magazine CAN Newsletter Online CiA Product Guides Cross media

Upload: others

Post on 25-Mar-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

1

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

CAN in Automation GmbH

Media kit 2022

CAN Newsletter magazineCAN Newsletter Online

CiA Product Guides Cro

ss m

edia

2

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

Tabl

e of

con

tent

s

Facts & figures 3

Overview 4 CAN Newsletter 5 • CAN Newsletter magazine • CAN Newsletter Online

CiA Product Guides 8 • CAN • CANopen • J1939

Further CiA marketing opportunities 9 • CANopen Product Panels at trade shows • CiA Posters: CANopen, CANopen FD, CANopen Lift

Technical data 10

Contact data 10

Order forms 11

3

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

Fact

s &

figu

res

258 922 124 519 306 136 21 601Article downloads Online page views News/articles Countries coverage CiA Info Mail

subscribers

CiA publication distribution

CiA publications are focused on CAN technology. The given figures refer to one year (November 01, 2020 to October 31, 2021) and are based on Google Analytics.

CAN Newsletter magazine 47 024 downloads of complete magazine 211 898 downloads of single articles

CAN Newsletter Online 92 053 page views per year

CiA Product Guides 32 466 page views per year

All three publications are referenced in the CAN Info Mail.

4

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

Ove

rvie

w

CiA publications provide technical information on CAN technology, CAN-related products and services, as well as on CAN applications and developments in the field. They are intended for CAN users and decision makers. In 2021 readers from 136 countries were reached.

Advertising in CiA’s publications CiA offers several advertising opportunities for your CAN-related products and services:

• Advertisement in CAN Newsletter magazine • Banners in CAN Newsletter Online • Product entries in the CiA Product Guides, which are referenced in further CiA publications • Advertisement in special-purpose CiA publications (e.g. posters)

Appeal to the CAN community directly with CiA publications!

All CiA publications are hyperlinked to each other. This includes the CAN Newsletter Online, CAN Newsletter magazine, the CiA Product Guides, the CiA e-mail services and social media channels.

Editor team

Olga Fischer Cindy Weissmueller

Nickel Plankermann

Holger Zeltwanger

Tobias Kammerer

Rosanna Rybin

Marketing team

Overview

For any issue, feel free to contact us per e-mail: Editor team: [email protected]

Marketing team: [email protected] or by phone: +49-911-928819-0

or you can make an appointment for an e-meeting.

5

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

Issue 1/22 2/22 3/22 4/22Publication date March 01 June 01 September 01 November 21Closing date for editorials January 17 April 11 July 18 October 10

Closing date for ad orders February 04 May 06 August 05 October 21

Closing date for art work February 14 May 17 August 19 November 07

Scope analysis * QuantityArticles in issues 1 - 4 / 2021 36Advertising companies 12

Figures from Google Analytics

* 4/2020 issue & 1-3/2021 issues

CAN Newsletter magazine 2020/2021Downloads from publication date until October 31, 2021:- complete magazine- single articles

CAN Newsletter magazine

CA

N N

ewsl

ette

r m

agaz

ine

The CAN Newsletter magazine (pdf) provides latest technical developments and application reports for CAN newcomers and CAN experts. Side notes provide service information such as abstracts, summaries, links, and brief company or technical background information.

6

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

CA

N N

ewsl

ette

r O

nlin

e

The CAN Newsletter Online provides CAN-related news on products, services and standardization. It also offers dossiers and features as well as editorial links to related articles or background information. Sponsored links to related products in the CiA Product Guides complete this.

Analysis

Total page views: 92 053 Total visitors: 43 321 Total articles: 269

Average monthly page views: 7 671 Average monthly visitors: 3 610

Visitors worldwide Google Analytics, from 2020-11-01 to 2021-10-31

Headbanner880 x 90 px.

Sidebanner210 x 210 px.

Skyscraper210 x 840 px.

Logo linked from CiA Product Guides entries

CAN Newsletter Online

Banner ads: formats and sizes

7

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

All rates are given in Euro excluding German VAT. Different combinations of advertisement and banner sizes are possible. Please contact us at [email protected] for your individual offer.

CAN Newsletter magazine

CiA members

Non- members

1/1 page, full color advertisement + skyscraper or headbanner

1 issue + 3-months banner 1.650,00 € 1.980,00 €

2 issues + 6-months banner 2.970,00 € 3.564,00 €

3 issues + 9-months banner 4.332,00 € 5.197,00 €

4 issues + 12-months banner 5.610,00 € 6.732,00 €

CAN Newsletter magazine

CiA members

Non- members

1/2 page, full color advertisement horizontal or vertical + sidebanner

1 issue + 3-months banner 1.105,00 € 1.326,00 €

2 issues + 6-months banner 1.989,00 € 2.387,00 €

3 issues + 9-months banner 2.900,00 € 3.480,00 €

4 issues + 12-months banner 3.757,00 € 4.508,00 €

Category pages

Skyscraper (210 x 840 px.)in main or sub categories

Headbanner (880 x 90 px.)in main or sub categories

Sidebanner (210 x 210 px.)in main or sub categories

Duration CiA members Non-members CiA members Non-members CiA members Non-members 3 months 600,00€ 720,00€ 500,00€ 600,00€ 300,00€ 360,00€ 6 months 1.080,00€ 1.296,00€ 900,00€ 1.080,00€ 540,00€ 648,00€ 9 months 1.575,00€ 1.890,00€ 1.312,00€ 1.575,00€ 787,00€ 945,00€12 months 2.040,00€ 2.448,00€ 1.700,00€ 2.040,00€ 1.020,00€ 1.224,00€

1/2 page, horizontal

210 x 148 mm

1/2 page,vertical

100 x 297 mm

or Sidebanner

210 x 210 px.

1/1 page

210 x 297 mm

Skyscraper

210 x 840 px.

+

+

or

Headbanner

880 x 90 px.

CA

N N

ewsl

ette

r m

agaz

ine

& O

nlin

e ad

vert

isem

entsCAN Newsletter magazine & CAN Newsletter Online advertisements

CAN Newsletter Online banner advertisements

Headbanners, Sidebanners, Skyscrappers can be only booked in the four main categories or one of available subcategories of the CAN Newsletter Online. Homepage of the CAN Newsletter Online is not available for this service.

8

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

CiA

Pro

duct

Gui

des

CiA Product GuidesCANopen, CAN and J1939 CiA members Non-members Special rates

Each entry (1 year duration) 250,00 € 500,00€ on request

The entry in the CiA Product Guides has a duration of 1 year from the date of publication. With the order confirmation you receive instructions on how to provide your material for your entry in the CiA Product Guides.

CiA Product Guides list CAN, CANopen, respectively J1939 products and services. Besides detailed technical descriptions, worldwide sales contacts are given. They are highly integrated into the CAN Newsletter Online and other CiA publications and marketing activities.

CiA Product Guides

Analysis

Total page views: 32 466 Total product guide entries: 165

Visitors worldwide Source: Google Analytics, from 2020-11-01 to 2021-10-31

9

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

Furt

her

mar

ketin

gop

port

uniti

es

Further marketing opportunities

CiA offers further opportunities to advertise your CAN-related products and services. This includes for example CANopen product panels on the CiA exhibition stands and CANopen, CANopen FD and CANopen Lift Posters.

Product Description Unit price (without German VAT)CANopen poster (841 mm x 594 mm) Advertisement 110 mm x 70 mm, 4-c 275,00 €CANopen FD poster (841 mm x 594 mm) Advertisement 110 mm x 70 mm, 4-c 275,00 €CANopen Lift poster (841 mm x 594 mm) Advertisement 110 mm x 70 mm, 4-c 275,00 €

CiA posters

The clearly structured DIN A1 wall posters provide the important technical details on CANopen, CANopen FD and CANopen Lift. The posters provide spaces for your advertisements. The spaces are available for CiA members only. The posters are intended for distribution at the trade shows.

CANopen® : CiA 301 - application layer and communication profile

© 2021 CAN in Automation (CiA) international users‘ and manufacturers‘ groupwww.can-cia.org

ServicesWe assist you!

◆ Profound seminars◆ Conformance assessment◆ Technical support◆ CiA Product Guides◆ Product panels

For more details please contact CiA office: [email protected]

www.can-cia.org

Index range Description0000h Reserved

0001h to 025Fh Data types0260h to 0FFFh Reserved1000h to 1FFFh Communication profile area2000h to 5FFFh Manufacturer-specific profile area6000h to 9FFFh Standardized profile areaA000h to AFFFh Network variablesB000h to BFFFh System variablesC000h to FFFFh Reserved

Index range Description1000h to 1029h General communication objects (CiA 301)

102Ah NMT inhibit time (CiA 302-2)1100h to 1107h CANopen security (CiA 322) (under development)1180h to 1186h CANopen energy saving (CiA 302-9)1200h to 12FFh SDO parameters (CiA 301)1300h to 13FFh CANopen safety parameters (EN 50325-5)1400h to 1BFFh PDO parameters (CiA 301)1F00h to 1F11h SDO manager (CiA 302-5)1F20h to 1F27h Configuration manager (CiA 302-3)1F2Ah to 1F4Fh CANopen multi-level networking (CiA 302-7)1F50h to 1F58h Program control parameters (CiA 302-3)

1F60h Redundancy configuration (CiA 302-6)1F70h Process image (CiA 302-4)1F78h CANopen message data reception (IEC 61375-3-3)

1F80h to 1F91h NMT manager parameters (CiA 302-2)1FA0h to 1FCFh Object scanner list (CiA 301)1FD0h to 1FFFh Object dispatching list (CiA 301)

Index Object Name1000h VAR Device type1001h VAR Error register1002h VAR Manufacturer status register1003h ARRAY Pre-defined error field1005h VAR COB-ID Sync message1006h VAR Communication cycle period1007h VAR Synchronous window length1008h VAR Manufacturer device name1009h VAR Manufacturer hardware version100Ah VAR Manufacturer software version100Ch VAR Guard time100Dh VAR Life time factor1010h VAR Store parameters1011h VAR Restore default parameters1012h VAR COB-ID time stamp1013h VAR High resolution time stamp 1014h VAR COB-ID EMCY1015h VAR Inhibit time EMCY1016h ARRAY Consumer heartbeat time1017h VAR Producer heartbeat time1018h RECORD Identity object1019h VAR Sync. counter overflow value1020h ARRAY Verify configuration1021h VAR Store EDS1022h VAR Storage format1023h RECORD OS command1024h VAR OS command mode1025h RECORD OS debugger interface1026h ARRAY OS prompt1027h ARRAY Module list1028h ARRAY Emergency consumer1029h ARRAY Error behavior

Object dictionary (OD)

Initializing

Applicationreset

Communicationreset

Pre-operational

Stopped

Operational

(3) (4)(5)

(7)

(6)(8)

(12) (13) (14)

(1)

(9) (10) (11)

(15)

(2) Boot-up message

Object dictionary index range 1000h to 1FFFh is reset

Object dictionary index range 2000h to FFFFh is reset

(1) Power on(2) Automatic switch to Pre-operational(3) and (6) NMT switch to Operational(4) and (7) NMT switch to Pre-operational(5) and (8) NMT switch to Stopped(9), (10) and (11) NMT switch to Application reset(12), (13) and (14) NMT switch to Communication reset(15) Power-off or hardware reset

DLC = 1

CAN-ID = 700h + node-ID

DLC = 1 (data field)

CAN-ID = 700h + node-ID

indication(s)

indication(s)

Heartbeatconsumer

time (1016h )in ms

Heartbeat

event

CAN-ID = 000h

DLC = 2 (data field)

request

request

request

request

Producer Consumer(s)

NMT manager NMT server

Node state values: 4d = Stopped 5d = Operational127d = Pre-operational

Command specifier (CS):001d = Start (go to Operational)002d = Stop (go to Stopped)128d = Go to Pre-operational129d = Reset node (Application reset)130d = Reset communication

Boot-up protocol

Heartbeatproducer

time (1017h )in ms

indication(s)

indication(s)

NMT-message protocol

Heartbeat protocol

0

Node state

Node state

CS Node-ID

Network management (NMT)

Sync protocol

CounterDLC = 0 or 1

Default CAN-ID = 080h

indication(s)request

Sync producer Sync consumer(s)

Default CAN-ID = 080h + node-ID

indication(s)request

Emergency producer Emergency consumer(s)

EMCY producer COB-ID (1014h)EMCY inhibit time (1015h)

EMCY consumer COB-IDs (1028h)

EEC = Emergency Error CodeER = Error Register (1001h)MEF = Manufacturer-specific Error Field

2 byte 1 byte 5 byteEEC ER MEF

Emergency protocol

DLC = 6

Default CAN-ID = 100h

indication(s)request

TIME COB-ID (1012h)

STRUCT OF UNSIGNED28 ms, (after midnight) VOID4 reserved_1, UNSIGNED16 days, (since January 1, 1984)

Time-stamp producer Time-stamp consumer(s)

TimeOfDay data

Time-stamp protocol

Special protocols

PDO communication parameter

DLC = 1 to 8

CAN-ID = pre-defined or user-specificApplication object(s)

request indication(s)

Producer Consumer(s)

PDO communication parameter

IIndex Sub-index Description Data typeRPDO: 1400h

to 15FFh

TPDO: 1800h

to 19FFh

00h Number of entries Unsigned801h COB-ID Unsigned3202h Transmission type Unsigned803h Inhibit time Unsigned1604h Reserved Unsigned805h Event timer Unsigned1606h SYNC start value Unsigned8

Index Sub Object contents1800h 01h COB-ID 1800h 02h Transmission type1800h 03h Inhibit time1800h 05h Event timer1800h 06h SYNC start value

1A00h 01h 2000h 01h 08h

1A00h 02h 2003h 03h 10h

1A00h 03h 2003h 01h 08h

2000h 01h Object A2000h 02h Object B2001h 00h Object C2002h 00h Object D2003h 01h Object E2003h 02h Object F2003h 03h Object G

TPDO 1 (CAN-ID see 1800h 01h)

CAN transmission

Data field

Object A Object G Object ECAN-ID

CAN-ID

Index Sub Object contents1400h 01h COB-ID 1400h 02h Transmission type1400h 03h Inhibit time1400h 05h Event timer

1600h 01h 2000h 01h 08h

1600h 02h 2003h 03h 10h

1600h 03h 2003h 01h 08h

2000h 01h Object A2000h 02h Object B2001h 00h Object C2002h 00h Object D2003h 01h Object E2003h 02h Object F2003h 03h Object G

RPDO 1 (CAN-ID see 1400h 01h)

CAN transmission

Data field

Object A Object G Object ECAN-ID

CAN-ID

TPDO parameter

RPDO parameter

Process data object (PDO)

Pre-defined CAN-IDsObject Specification CAN-ID

NMT CiA 301 000h

Global failsafe command EN 50325-5 001h

Flying manager CiA 302-2 071h to 076h

Indicate active interface CiA 302-6 07Fh

Sync CiA 301 080h

Emergency CiA 301 081h to 0FFh (080h + node-ID)

Time stamp CiA 301 100h

Safety-relevant data objects EN 50325-5 101h to 180h

TPDO 1 CiA 301 181h to 1FFh (180h + node-ID)

RPDO 1 CiA 301 201h to 27Fh (200h + node-ID)

TPDO 2 CiA 301 281h to 2FFh(280h + node-ID)

RPDO 2 CiA 301 301h to 37Fh (300h + node-ID)

kurze Tabelle 1

Object Specification CAN-ID

TPDO 3 CiA 301 381h to 3FFh(380h + node-ID)

RPDO 3 CiA 301 401h to 47Fh (400h + node-ID)

TPDO 4 CiA 301 481h to 4FFh (480h + node-ID)

RPDO 4 CiA 301 501h to 57Fh (500h + node-ID)

Default SDO server-to-client CiA 301 581h to 5FFh (580h + node-ID)

Default SDO client-to-server CiA 301 601h to 67Fh (600h + node-ID)

Dynamic SDO request CiA 302-5 6E0h

Node claiming procedure CiA 416-1 6E1h to 6E3h

Node claiming procedure CiA 416-1 6F0h to 6FFh

NMT error control CiA 301 701h to 77Fh (700h + node-ID)

Layer setting services CiA 305 7E4h to 7E5h

www.b-plus.com

b-CANCubeMini

www.peak-system.comInterfaces to the CANopen World and

Solutions for your CAN or CAN FD Application

OD

Client SDO

Server SDO

Node n-1

Node n

ID n DataID p Data

DLC = 8CAN-ID client-to-server for Default-SDO = 600h + node-IDCAN-ID server-to-client for Default-SDO = 580h + node-ID

Client Server

CS: Command specifier (read or write access, transfer type)MUX: Multiplexer (index and sub-index of an object)

initiate SDO downloadCS MUX DATAinitiate SDO download responseCS MUX Not used

initiate SDO uploadCS MUX Not used

initiate SDO upload responseCS MUX DATA

initiate SDO download

CS MUX (Length)initiate SDO download responseCS MUX Not used

download SDO segment 1CS DATAdownload segment 1 response

CS Not useddownload segment 2 to n-1

CS DATAdownload segment 2 to n-1 response

CS Not useddownload segment n

CS DATAdownload segment n response

CS Not used

Client Server

CAN-ID client-to-server for Default-SDO = 600h + node-IDCAN-ID server-to-client for Default-SDO = 580h + node-ID

Normal SDO protocol

SDO abort codes

Expedited SDO protocol

Service data object (SDO)

IAbort code Description

0503 0000h Toggle bit not alternated

0504 0000h SDO protocol timed out

0504 0001hClient/server command specifier not valid or unknown

0504 0002h Invalid block size (block mode only)

0504 0003hInvalid sequence number (block mode only)

0504 0004h CRC error (block mode only)

0504 0005h Out of memory

0601 0000h Unsupported access to an object

0601 0001h Attempt to read a write only object

0601 0002h Attempt to write a read only object

0602 0000hObject does not exist in the object dictionary

0604 0041h Object cannot be mapped to the PDO

0604 0042hNumber, length of the objects would exceed PDO length

0604 0043hGeneral parameter incompatibility reason

0604 0047hGeneral internal incompatibility in the device

0606 0000h Access failed due to an hardware error

IAbort code Description

0607 0010hData type does not match, length does not match

0607 0012hData type does not match, length too high

0607 0013hData type does not match, length too low

0609 0011h Sub-index does not exist

0609 0030hInvalid value for parameter (download only)

0609 0031hValue of parameter written too high (download only)

0609 0032hValue of parameter written too low (download only)

0609 0036hMaximum value is less than minimum value

060A 0023h Resource not available: SDO connection0800 0000h General error0800 0020h Data cannot be transferred

0800 0021hData cannot be transferred or stored to the application because of local control

0800 0022hData cannot be transferred because of the present device state

0800 0023hObject dictionary dynamic generation fails or no object dictionary is present

0800 0024h No data available

Overview

Communication profile area

General communication objects

neoVI RED 2Multiple protocol tools with a low-cost, high-value vehicle bus interface and data logger. Find out more: www.intrepidcs.com/red2

USA Germany UK Japan Korea China India Australia

+49 (0)721 1803083 -1 [email protected]

Inclusive languageCiA is committed to use inclusive language in its specifications and technical reports. CiA documents are going to be updated with the following inclusive terms:◆ NMT manager (non-inclusive: NMT master)◆ NMT server (non-inclusive: NMT slave)◆ LSS manager (non-inclusive: LSS master)◆ LSS server (non-inclusive: LSS slave)◆ Application manager (non-inclusive: Application master)◆ Flying manager (non-inclusive: Flying master)

Profound seminarsConformance assessment

Technical supportProduct Guides

Product wall

www.can-cia.org [email protected]

We assist you!Services

Educ

atio

n

Con

sulti

ng

Test

ing

Mar

ketin

g

Publ

icat

ions

110 mm x 70 mm

110 mm x 70 mm

110 mm x 70 mm

110 mm x 70 mm

110 mm x 70 mm

110 mm x 70 mm

110 mm x 70 mm110 mm x 70 mm110 mm x 70 mm110 mm x 70 mm110 mm x 70 mm110 mm x 70 mm110 mm x 70 mm

SampleSample

10

www.can-newsletter.org • www.cia-productguides.org • www.can-cia.org

CAN in Automation CAN in Automation @CANopen CANinAutomation

Tech

nica

l & c

onta

ct d

ata

Publisher: CAN in Automation GmbH Kontumazgarten 3 DE-90429 Nuremberg

Phone: +49-911-928819-0 Fax: +49-911-928819-79 www.can-cia.org Editors: Holger Zeltwager (responsible according to the press law) Olga Fischer Cindy Weissmueller Nickel Plankermann

[email protected] Advertising: Birgit Ruedel (responsible according to the press law) Tobias Kammerer Rosanna Rybin

[email protected]

Technical dataRates: All rates are given in Euro excluding German VAT and do not include any agency discount. CAN Newsletter magazine: Please, send your artwork preferable as pdf file with a 300-dpi resolution by email to [email protected]. Banner advertisements: Please, send your files as gif-, jpg-, png- or flash-files with a 72 dpi resolution to [email protected]. General: Please, send all information to be advertised and to be used for editorial purposes only in English language. Press: Our editors are looking forward to receiving your press releases and detailed technical articles at [email protected].

Contact data

Kontumazgarten 3 Tel. +49-911-928819-0 [email protected] CEO: Reiner ZitzmannDE-90429 Nuremberg Fax +49-911-928819-79 www.can-cia.org AG Nürnberg HRB 24338

Order form CAN Newsletter magazine advertisements

Sizes and basic rates for advertisements are given in the media kit (effective January 1, 2022).

Company

Street

ZIP, City

VAT ID

Order no.

Name

E-Mail

Phone

Date / signature / stamp

Order address Invoice address(if different from order address)

CiA members Non-members1/1 page, full color advertisement + skyscraper or headbanner1 issue + 3-months banner2 issues + 6-months banner3 issues + 9-months banner4 issues + 12-months banner

CiA members Non-members1/2 page, full color advertisement horizontal or vertical + sidebanner1 issue + 3-months banner2 issues + 6-months banner3 issues + 9-months banner4 issues + 12-months banner

Ord

er fo

rm C

AN

New

slet

ter

mag

azin

e ad

vert

isem

ent

Kontumazgarten 3 Tel. +49-911-928819-0 [email protected] CEO: Reiner ZitzmannDE-90429 Nuremberg Fax +49-911-928819-79 www.can-cia.org AG Nürnberg HRB 24338

Order form CAN Newsletter Online - Banner advertisements

Category pages Skyscraper Headbanner Sidebanner

Duration CiA members Non-members CiA members Non-members CiA members Non-members

3 months

6 months

9 months

12 months

Start (home) page Skyscraper Headbanner Sidebanner

Duration CiA members Non-members CiA members Non-members CiA members Non-members

3 months

Sizes and basic rates for advertisements are given in the media kit (effective January 1, 2022).

Company

Street

ZIP, City

VAT ID

Order no.

Name

E-Mail

Phone

Date / signature / stamp

Order address Invoice address(if different from order address) Ord

er fo

rm C

AN

N

ewsl

ette

r O

nlin

e

Headbanners, Sidebanners, Skyscrappers can be only booked in the four main categories or one of available subcategories of the CAN Newsletter Online. Homepage of the CAN Newsletter Online is not available for this service.

Kontumazgarten 3 Tel. +49-911-928819-0 [email protected] CEO: Reiner ZitzmannDE-90429 Nuremberg Fax +49-911-928819-79 www.can-cia.org AG Nürnberg HRB 24338

Sizes and basic rates for advertisements are given in the media kit (effective January 1, 2022).

Company

Street

ZIP, City

VAT ID

Order no.

Name

E-Mail

Phone

Date / signature / stamp

Order address Invoice address(if different from order address)

Ord

er fo

rmpo

ster

by

CiA

Order form: advertisements on poster by CiA(for distribution at CiA exhibition booth, other CAN-related events, etc.)

Product Description Order

CANopen poster (841 mm x 594 mm) Advertisement 110 mm x 70 mm, 4-c

CANopen FD poster (841 mm x 594 mm) Advertisement 110 mm x 70 mm, 4-c

CANopen Lift poster (841 mm x 594 mm) Advertisement 110 mm x 70 mm, 4-c

Kontumazgarten 3 Tel. +49-911-928819-0 [email protected] CEO: Reiner ZitzmannDE-90429 Nuremberg Fax +49-911-928819-79 www.can-cia.org AG Nürnberg HRB 24338

Sizes and basic rates for advertisements are given in the media kit (effective January 1, 2022).

Company

Street

ZIP, City

VAT ID

Order no.

Name

E-Mail

Phone

Date / signature / stamp

Order address Invoice address(if different from order address)

Ord

er fo

rmC

iA P

rodu

ct G

uide

s

Order form CiA Product Guides

Please use last year´s data.

We will send new / updated data.

CiA member

Non-member

CANopen CAN J1939

Number of entries

Combination with CANopen product panel