operational capability: provides an interface for remote monitoring of a digital power meter...

2
Operational Capability : •Provides an interface for remote monitoring of a digital power meter •Communicates meter reading back to power company over a variety of communications interfaces •900MHz radio •802.11 •Bluetooth •Ethernet •Broadband over Power Line •Provides a viable method for monitoring power consumption in real time •Eliminates need for physical inspection of meter each month Power Meter Monitoring Unit Proposed Technical Approach: Task 1 – Meter Interface: •Study requirements for interfacing with digital power meter •Develop µController hardware and software to interface with power meter Task 2 – Communications Interface: •Determine most viable communications platforms for transmission of data received from meter •Develop hardware/software that allows for multiple communications platforms in one PCB design Task 3 – Data Management: •Develop software to organize data received Schedule and Rough Order of Magnitude Cost : Task 1: 2 – 3 months to develop meter interface; $30,000 Task 2: 2 – 3 months to develop communications interface; $30,000 Task 3: 1 – 2 months to develop database interface; $10,000 Deliverables : •Report detailing the use of available communications platforms •Report detailing the methodology for interfacing with power meter •Hardware for µController and communications interfaces •Software to read data from meter and transmit data over desired communications platform •Software to received data from unit and create database of meter readings •User interface to allow company/customer Anthony Allison anthony.allison@trace- innovations.com February 10, 2006 Pow erC om pany 900M H z 802.11 µC Ethernet/BPL U serInterface

Post on 19-Dec-2015

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Operational Capability: Provides an interface for remote monitoring of a digital power meter Communicates meter reading back to power company over a variety

 

Operational Capability:•Provides an interface for remote monitoring of a digital power meter•Communicates meter reading back to power company over a variety of communications interfaces

•900MHz radio•802.11•Bluetooth•Ethernet•Broadband over Power Line

•Provides a viable method for monitoring power consumption in real time•Eliminates need for physical inspection of meter each month

Power MeterMonitoring Unit

Proposed Technical Approach:Task 1 – Meter Interface:•Study requirements for interfacing with digital power meter•Develop µController hardware and software to interface with power meterTask 2 – Communications Interface:•Determine most viable communications platforms for transmission of data received from meter•Develop hardware/software that allows for multiple communications platforms in one PCB designTask 3 – Data Management:•Develop software to organize data received from meter units•Create user interface to poll database of received meter readings

Schedule and Rough Order of Magnitude Cost :Task 1: 2 – 3 months to develop meter interface; $30,000 Task 2: 2 – 3 months to develop communications interface; $30,000Task 3: 1 – 2 months to develop database interface; $10,000

Deliverables:•Report detailing the use of available communications platforms•Report detailing the methodology for interfacing with power meter•Hardware for µController and communications interfaces•Software to read data from meter and transmit data over desired communications platform•Software to received data from unit and create database of meter readings•User interface to allow company/customer review of meter readings

Corporate Information:TRACE Innovations 2202 Young PL #BAnthony Allison Bryan, TX [email protected] 979-324-8740

Anthony [email protected] 10, 2006

Power Company

900MHz802.11

µC

Ethernet/BPL

User Interface

Page 2: Operational Capability: Provides an interface for remote monitoring of a digital power meter Communicates meter reading back to power company over a variety

 

Operational Capability:•Controls timing and amount of water used for lawn irrigation based on:

•Wind speed•Temperature•Humidity•Soil saturation•Sunlight•Time of day

•Uses system that eliminates manual timer and requires minimal homeowner adjustment•Allows watering of specific zones of a yard•Reduces amount of water consumed by making best use of watering times

Sprinkler System SensorNetwork/Control System

Proposed Technical Approach:Task 1:•Study factors affecting when to and when not to water the lawn•Study sensors that can measure the above defined factorsTask 2:•Develop sensor platforms specific to lawn irrigation•Weatherproof sensor platformsTask 3:•Develop base station to receive sensor communications•Develop software to control sprinklers based on sensor measurements

Schedule and Rough Order of Magnitude Cost :Task 1: 2 – 3 weeks to study environmental factors; $10,000 Task 2: 2 – 3 months to develop sensor packages; $30,000Task 3: 3 – 5 months to develop control system & communications interface; $50,000Deliverables:•Report detailing environmental factors that affect the system•Control unit and sensor platforms•Control unit software•Detailed technical drawings of all hardware•User manuals for installation and operation

Corporate Information:TRACE Innovations 2202 Young PL #BAnthony Allison Bryan, TX [email protected] 979-324-8740

Anthony [email protected] 10, 2006

WirelessSensor

WirelessSensor

WirelessSensor

ControlStation

WirelessSensor