(prefix t26 changes to d26 for dual element) - temprel · t26 configurator flexible lead wire...

2
T 26 THERMOCOUPLES 13

Upload: others

Post on 09-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: (Prefix T26 Changes to D26 for Dual Element) - Temprel · T26 CONFIGURATOR Flexible lead wire thermocouple with integrated spring wire support on the heavy duty transition. #1 Connectors

T26THERMOCOUPLES

13

Page 2: (Prefix T26 Changes to D26 for Dual Element) - Temprel · T26 CONFIGURATOR Flexible lead wire thermocouple with integrated spring wire support on the heavy duty transition. #1 Connectors

E -G -S -U -

U2 -

ExposedGroundedSemi-ShieldedUngroundedUngrounded Separate for Dual Element

Junction Type#2

Specify Probe Length in Inches#3

Inches

AAA -AA -

A -B -

.032” (34 AWG wire)

.040” (32 AWG wire)

.062” 1/16” (28 AWG wire)

.090” (25 AWG wire)

Probe Diameter#5C -D -E -

.125” 1/8” (22 AWG wire)

.188” 3/16” (19 AWG wire)

.250” 1/4” (16 AWG wire)

GP -LA -LC -LE -

P -V -

Overbraid Grounded to TransitionStainless Steel with High Temperature Epoxy (600 oF)

Stainless Steel with High Temperature Ceramic Potting (2800 oF)

Stainless Steel with Epoxy Potting (500 oF)

Molded on Plastic Rated (525 oF) for .062 & .125 Diameters Only

Vibration Resistant Construction

Transition#7

Length as measured from transition to the connector.

Specify Wire Length in Inches#8

www.temprel.com

Need Help Placing an Order or Have Questions? Call (800) 582-5098

T26 CONFIGURATORFlexible lead wire thermocouple with integrated spring wire support on the heavy duty transition.

Connectors#1

______ -

Calibration#4

1 27

4

38

(stranded wire) (stranded wire) (stranded wire)

(stranded wire) (stranded wire)

- Fiberglass- High Temp Fiberglass- Polyimide- PVC

- Fluoropolymer FEP

Wire Insulation#9

2F 2G2K2P2T

(solid wire)

(solid wire)

(solid wire)

(solid wire)

(solid wire)

4F4G4K 4P4T

see page # 37-38

see page # 29-30

______ -

**Probe lengths may vary +/- .125” unless otherwise specified.

Sample shown: T26-6J-AI-LC6-R4TWP

(Prefix T26 Changes to D26 for Dual Element)1 2 3 4 5 6

T26 :7 8 9 10

S -S10 -S16 -

304 Stainless Steel310 Stainless Steel316 Stainless Steel

Probe Material#6 see page # 37-38

I -H -

Inconel®

Hastelloy X®

10

T JE K

BP -CP -

HPT -18PP -14PP -38PP -

R - RT -W2 -WP -

FEP -PFA -

Bullet PointCone PointHypodermic Point (Sharpened to needle point)

1/8” Pipe Plug1/4” Pipe Plug3/8” Pipe PlugStainless Steel Wire Overbraid on Lead WiresReduced Tip ( .125” to .062” diameter)

Washer (Only available with .062” or 1/16” probe diameter)

Weld Pad (Only available with .062” or 1/16” probe diameter)

FEP Coated Probe (.040”, .062”, .125”, .188” .250” diameter)

PFA Coated Probe (.040”, .062”, .125”, .188” .250” diameter)

Available Options#10**Leave blank for standard probe tip.

J -JSR -

M -MJ -

MJSR -MP -

MPSR -O -

OC -P -

PSR -S -

S3 -T -

Put on Standard-JackPut on Standard-Jack with Strain Relief Molded on Mini-PlugPut on Mini-JackPut on Mini-Jack with Strain ReliefPut on Mini-PlugPut on Mini-Plug with Strain ReliefOpen Wire end, No Connector OptionOpen Wire (wire blunt cut)

Put on Standard-PlugPut on Standard-Plug with Strain ReliefMolded on Standard-PlugMolded on 3 Prong Standard-PlugTerminals (Specify type & size when placing your order)

**Append prefix “R” to the begining of any options listed below to call forStainless Steel Overbraid on wire. Example “R4F”

T26

TH

ER

MO

CO

UP

LES

14