pressed metal door framescommercialpaneldevelopments.com.au/wp-content/... · frame ordering...

12
COMMERICAL PANEL DEVELOPMENTS PTY LTD commercialpaneldevelopments.com.au ACN:082754158 ABN:68 082 754 158 PRESSED METAL DOOR FRAMES

Upload: others

Post on 25-Jul-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

C O M M E R I C A L P A N E L D E V E L O P M E N T S P T Y L T Dc o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

A C N : 0 8 2 7 5 4 1 5 8 A B N : 6 8 0 8 2 7 5 4 1 5 8

PRESSEDMETALDOORFRAMES

Page 2: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

2 c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

Page 3: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

3c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

OUR PHILOSOPHYT h e C o m m e r c i a l P a n e l D e v e l o p m e n t s p r o v i d e s t h e h i g h e s t l e v e l o f p r o d u c t q u a l i t y w i t h t h e s h o r t e s t r e s p o n s e t i m e i n t h e i n d u s t r y . P r e s s e d M e t a l D o o r f r a m e s a r e 1 0 0 % A u s t r a l i a n o w n e d a n d m a d e .

I n o r d e r t o d o t h i s , C o m m e r c i a l P a n e l D e v e l o p m e n t s r u n a v e r y f l e x i b l e m a n u f a c t u r i n g o p e r a t i o n w h e r e w e c a n r e s p o n d t o t h e e v e r c h a n g i n g m a r k e t d e m a n d s . A t C o m m e r c i a l P a n e l D e v e l o p m e n t s , w e l i k e t o c o n s i d e r o u r s e l v e s t h e a p p r o a c h a b l e m a n u f a c t u r i n g c o m p a n y , i f y o u h a v e a n i n q u i r y , w e w a n t t o h e a r a b o u t i t . W e a r e o n l y t o o h a p p y t o r e c e i v e y o u r r e q u e s t s f o r q u o t a t i o n s o r o r d e r s f o r s p e c i a l p r o j e c t s t h a t c a n b e m a n u f a c t u r e d t o y o u r n e e d s .

Page 4: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

4 c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

Profile:

110mm, brick you would select a frame with a throat size = 114mm for wrap around140mm block work, you would select a 145mm throat size190mm block work, you would select a 193mm throat size

When ordering frames for partition stud walls, you must allow for the stud thickness and lining thickness.

A stud wall with 13mm PB Lining plasterboard either side and a 64mm Metal Stud would give you a wall thickness of 90mm - You would select our N93 profile which has a throat size of 93mm.

FRAME ORDERING PROCEEDURE

E.g.

Please note

E.g.

Common Fixing Methods:

New masonry walls = Wire tiesExisting masonry walls = Dyna fixingsStud walls = saddles, strap fixings or counter sunk holes

E.g.

Rebate Size:

The rebate size is determined by the door thickness

35mm thick door = 41mm rebate40mm thick door = 43mm to 45mm rebateStandard rebate sizes are, 41mm, 43mm, 45mm & 51mm

E.g.

Reveal Sizes:

Reveal Height = Door height + clearance gaps and allow for floor finish thicknessReveal Width = Door width + 3mm clearance gaps, double doors allow 10mmStandard Reveal heights are : Non rated frames - Standard 2060mm : Fire rated frames - 2055mm

Reveal Height = 2040mm door + 20mm for door clearances = Standard 2060mm reveal,Reveal Width = 820mm door + 6mm for door clearances = 826mm revealFrame reveal = 2060 x 826mm

E.g.

Page 5: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

5c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

Handling:

When determining the door handing of a door frame, pull the door open towards you and which ever side the hinges are on is the handing.

Hinge Type:

Specify - Quantity, Type and Finish. Preparation for screw fixed hinges onlyExternal doors, solid core doors & steel doors generally have 3 hinges or even more depending on size and weight of the door.

Assembly Method:

Frames are supplied - Welded, Dressed & Primed

Orders:

The following details will be requested prior to manufacture

1. Order number

2. Contact name

3. Phone number

4. Transport details

5. Delivery address

6. Date required

LEFT HAND DOUBLE DOORS RIGHT HAND DOUBLE

ACTION

FIXING METHODS FOR MASONRY/CONCRETE

Face Fix Wrap Around Tilt Panel - Cast in Dyna Fix

FIXING METHODS FOR STUD

Fire Rated Strap Fixings Standard Strap Fixings Wrap Around Flanged Flanged Frame

Page 6: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

6 c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

FIXING METHODS

LEFT HAND DOUBLE DOORS RIGHT HAND DOUBLE

ACTION

FIXING METHODS FOR MASONRY/CONCRETE

Face Fix Wrap Around Tilt Panel - Cast in Dyna Fix

FIXING METHODS FOR STUD

Fire Rated Strap Fixings Standard Strap Fixings Wrap Around Flanged Flanged Frame

SPECIFICATIONS FOR METAL DOOR FRAMES

Material: Non-rated frames manufactured from 1.15mm zincanneal and galvanised metal sheetFire-rated frames manufactured from 1.55mm zincanneal and galvanised metal sheetStandard Reveal Heights: Non rated frames 2060 and Fire rated frames 2055Standard Reveal Widths: 626 / 726 / 826 / 876 / 926Standard Widths Doubles: 1250 / 1445 / 1650Hinges: As requestedLock Prep: Standard striker preparation @ standard height -1042mmFixings: Wire ties fixings for new masonry wallsPacking: Individually wrapped and strapped onto timber skids, for ease of transportationLabelling: Individually numbered or labelled upon request.

Page 7: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

7c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

DOOR FRAME INDUSTRY TERMINOLOGY

REVEAL WIDTH

REVEAL HEIGHT

O/ALLHEIGHT

LOCK HEIGHTSTD = 1000MM

O/ALL WIDTH

HEAD

300MM

1052MM

1765MM

250MM

STANDARD HINGEAND LOCK POSITIONS

FOR NON RATED FRAMES

DOOR STOP: VAIRES

ARCHITRAVE: 38mm

THROAT SIZE: VARIES

REBATE

DOOR STOP Non rated = 15mmHEIGHT Fire rated = 25mm

RETURN: 15mm

REBATE SIZE: 41, 43 & 51mm

Page 8: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

8 c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

NON RATED FRAMES

STANDARD SIZES AND PROFILES

N86 - Frame Singles: 2060 x 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 Non standard reveal widths, can be supplied to your project

38

15

38

15

4141

1212 86

N86

24

9

N93 - Frame Singles: 2060 x 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 / 1750 / 1850Non-standard reveal widths, add to above prices

38

15

38

15

4141

1212 93

N93

35

9

N102 - Frame Singles: 2060 x 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 / 1750 / 1850Non-standard reveal widths, add to above prices

38

15

38

15

4141

1212 102

N102

44

9

N114 - Frame Singles: 2060 x 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 / 1750 / 1850Non-standard reveal widths, add to above prices

38

15

38

15

4141

1212 114

N114

54

9

N145 - Frame Singles: 2060 x 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 / 1750 / 1850Non-standard reveal widths, add to above prices

38

15

38

15

4141

1212 145

N145

87

9

N194 - Frame Singles: 2060 x 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 / 1750 / 1850Non-standard reveal widths, add to above prices

38

15

38

15

4141

1212 194

N194

136

9

SD114 - Frame Singles: 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 /1750 /1850Non-standard reveal widths, add to above prices

Page 8

38 38

1212 114

SD114

138

9 9

SD93 - Frame Singles: 626 / 726 / 776 / 826 / 876 / 926Doubles: 2060 x 1250 / 1450 / 1650 /1750 /1850Non-standard reveal widths, add to above prices

1212 93

38SD93

117

9 938

Page 9: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

9c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

STANDARD SIZES AND PROFILES

F114 - Frame

Singles: 2055 x 726 / 826 / 876 / 926To suit 40mm thick fire doors

To suit 40mm thick fire doors

F126* - FrameSingles: 2055 x 726 / 826 / 876 / 926To suit 40mm thick fire doors

F145 - FrameSingles: 2055 x 726 / 826 / 876 / 926To suit 40mm thick fire doors

F193 - FrameSingles: 2055 x 726 / 826 / 876 / 926To suit 40mm thick fire doors

FM114* - FrameSingles: 2055 x 726 / 826 / 876 / 926Doubles: 2055 x 1250 / 1450 / 1650 / 1750 / 1850 To suit 47mm thick fire doors

FM145* - FrameSingles: 2055 x 726 / 826 / 876 / 926Doubles: 2055 x 1250 / 1450 / 1650 / 1750 / 1850To suit 47mm thick fire doors

FM193* - FrameSingles: 2055 x 726 / 826 / 876 / 926Doubles: 2055 x 1250 / 1450 / 1650 / 1750 / 1850

Australian Architectural Fire Doors

38

25

38

25

4343

1212 114

F114

56

38

25

38

25

4343

1212 126

F126

68

38

25

38

25

4343

1212 145

F145

87

38

25

38

25

5151

1212 114

FM114

36

38

25

38

25

5151

1212 145

FM145

67

1212 193

38

25

38

25

5151

FM193

115

1212 193

38

25

38

25

4343

F193

136

FIRE RATED FRAMES

Page 10: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

1 0 c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

DOOR ORDERING PROCEEDURE

Door Sizes:Height, Width and Rebate WidthDoor frame reveal sizeNote: From finish floor height

Door thickness:40mm Thick = Mini or48mm Thick = Maxi

Note : If doors are to be metal clad add 5mm to finish thicknessDouble doors only 45mm and are supplied with aluminium meeting stiles

Hour Rating:1, 2, 3 or 4 Hour Fire Rating

Internal or external:Specify if door will be internal or external

Door Finish:MDF, PLY, Special Veneer or Metal Clad

Special Reinforcing:All fire doors are manufactured with reinforcement plates to accept lock, closer & 3 x hinges in standard positions. If alternative or additional hardware is to be fitted, please specify as this will ensure that when installing fire doors, all hardware has correct fixing provisions.

Orders:The following details will be requested prior to manufacture

1. Order number

2. Contact name

3. Phone number

4. Transport details

5. Delivery address

6. Date required

Before we can commence with the manufacture of your fire doors, we will require the following information. Note: We recommend, that all door openings are site measured prior to ordering.

Page 11: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties
Page 12: PRESSED METAL DOOR FRAMEScommercialpaneldevelopments.com.au/wp-content/... · FRAME ORDERING PROCEEDURE E.g. Please note E.g. Common Fixing Methods: New masonry walls = Wire ties

c o m m e r c i a l p a n e l d e v e l o p m e n t s . c o m . a u

COMMERCIAL PANEL DEVELOPMENTS PTY LTD

Depot: Unit 32/121 Kerry Road,Archerfield QLD 4108

R&D Works: 40 Ingleston Road,Wakerley QLD 4154

Manufacturing: 11 Priestley Street,Mittagong NSW 2575

Accounts:P.O Box 1772Bundaberg, Qld 4670P: 07 4155 6001M: 0422 951 717E: [email protected]: www.commercialpaneldevelopments.com.au