5796 and 7314-G30 expansion units Sundance-IB 7314 Dual 5796 I/O Unit Enclosure 19-inch Rack Mounting Hardware
The #7314 provides the mounting hardware required to install a #5796 PCI-DDR 12X Expansion Drawer in a
#0551, #0553, #0554 or #0555 19-inch rack. The enclosure can accommodate two #5796 drawers, side by
side, but it may also be used with only one #5796 drawer installed.
4 EIA units of rack space are required in a #0551, #0553, #0554 or #0555 rack.
The #7314 has rails adjustable to 29.25 inches depth.
Supported on Model 570 (POWER6).
The #7314 is a Customer Install Feature.
For System i POWER6 model 570 models, the only supported I/O drawer supporting 12X loop attachment is
the #5796 12X I/O Drawer. Two #5796 drawers can be enclosed in a #7314 enclosure. Key characteristics
of the #5796 include:
– 6 high speed, PCI-X DDR slots per #5796
– Dual mode or IOP-less IOAs only (no IOP support)
Picture shows two #5796s in a #7314 enclosure
Levko Fattori IBM Slovenia 3
Location code Description
C1, C2, C3, C4, C5, and C6 PCI slots. See also “PCI slot descriptions” on page 16
. C7-T1 and C7-T2 InfiniBand 12X connectors.
C8-T1 and C8-T2 Dual port SPCN connectors.
E1 and E2 Power supply connectors.
http://w3-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/TD104011?Open
Levko Fattori IBM Slovenia 4
9406-MMA and IO drawer 7314-G30_SPCN connections - Power Control Loop
The cables lenghts chose in the diagram are for example only.
6006 SPCN 3m Cable
6007 SPCN 15 m Cable
6008 SPCN 6 m Cable
Levko Fattori IBM Slovenia 5
http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphau/partscables_external.htm
SPCN cable (3 meters) (System i5 and System p5 CIN 6006) 22R5239*
09P1251**
SPCN cable (15 meters) (System i5 CIN 1465, System i5 and System p5 CIN 6007) 22R5221*
21F9358**
SPCN cable (6 meters) (System p5 CIN 1464, System i5 and System p5 CIN 6008) 22R5219*
21F9469**
* Designed to comply with RoHS requirement ** Not designed to comply with RoHS requirement
Levko Fattori IBM Slovenia 6
H192246 : SPCN cable FC 6006 requirements on MMA TEXT:
This tip resolves the confusion over the
requirement that multi-enclosure 9117 MMA
systems have an SPCN cable installed between the two Service
Interface cards located in the top 2 CEC enclosures. These cards are
also commonly referred to as FSP or Service Processor cards.
The SPCN cable completes the SPCN cable loop
when optional external I/O drawers or towers are connected.
Systems equipped with Firmware release 01EM320 or later will
automatically have Service Processor redundancy enabled, so both
FSPs must be included in the SPCN loop to allow either FSP to control
the external devices.
The IBM order system was recently updated to force
the inclusion of the SPCN cable between the FSP cards
in the top two enclosures regardless of whether the
order included external I/O drawers. This
configuration requirement insures that the cable is
already available or installed in the event that the
system configuration is changed to include external
I/O drawers. Orders for multi-enclosure systems
shipped prior to 2008 did not include the cable;
however, the order system will now automatically add
this cable when any MES activity is processed against
those systems.
From a functional perspective, this cable is NOT
required UNLESS external I/O drawers are present. The cable is NOT
Levko Fattori IBM Slovenia 7
required for Service Processor failover capability to be enabled or to
function correctly. However, if the cable is available, it should be
installed.
The following information is in the Sales Manual.
It is provided for reference.
Each p570 system with two or more CEC enclosures (eight
or more processor cores) that includes the attachment of
remote I/O drawers must have one Power Control Cable
(#6006 or similar) to connect the Service Interface Card
in the first enclosure to the Service Interface Card in
the second enclosure. In these configurations both
Service Interface Cards must be included in the Power
Control Cable loop.
(#6006) Power Control Cable (SPCN) - 3 meter
This feature provides a three-meter power control cable.
Attributes provided: 3M power control cable.
Attributes required: two drawers in the same rack.
For 9117-MMA: (#6006)
- Minimum required: 0
- Maximum allowed: no max (Initial order maximum: no max)
- OS level required: none
Initial Order/MES/Both/Supported: Both
CSU: Yes
Return parts MES: No
Note: Each system with two or more CEC enclosures requires one
SPCN cable to connect the Service Interface Card in the first
enclosure (uppermost enclosure in the stack) with the Service
Interface Card in the second enclosure.
SAS Keywords
Levko Fattori IBM Slovenia 8
#6446 12X Short Run 5796 Attach
The #6446 adapter provides the interface for attachment of the #5796 I/ O Drawer to a 12X Channel
loop.The adapter includes two 12X Channel connectors and is inserted into the #5796. This adapter does not
include the repeater function and is intended to support configurations where the host system and the
#5796 I/O drawers in the loop are located in the same rack.
The 12X cables attached to this adapter have the following restrictions. Cables between this adapter and a
host system cannot exceed 3.0 meters in length. Cables between two I/O drawers cannot exceed 1.5 meters
if both I/O drawers include this Short Run adapter feature #6446. Cables between two I/O drawers cannot
exceed 3.0 meters if either of the I/O drawers includes this Short Run adapter feature #6446. The
required 12X cables are ordered under a separate feature number. For longer cables, see the long run
adapter #6457.
There is a connecting rule for 12X cables and 12X adapters. For more information about this rule, see 4.13.1,
“System i POWER6 Model 570 I/O enhancements” on page 299.
Supported on Model 570 (POWER6).
The #6446 can be attached only #5796 I/O drawer.
The #6446 is a Customer Install Feature
#6457 12X Long Run 5796 Attach
The #6457 adapter provides the interface for attachment of the #5796 I/ O drawer to a 12X channel loop.
The adapter includes two 12X channel connectors and is inserted in the #5796. This adapter includes the
repeater function and can support longer cable loops allowing drawers to be located in adjacent racks. The
12X cables up to 8 meters in length can be attached to this adapter. The required 12X cables are ordered
under a separate feature number.
There is a connecting rule for 12X cables and 12X adapters. For more information about this rule, see 4.13.1,
“System i POWER6 Model 570 I/O enhancements” on page 299.
Supported on Model 570 (POWER6).
The #6457 can be attached only #5796 I/O drawer.
The #6457 is a Customer Install Feature.
Levko Fattori IBM Slovenia 9
Index
number CCIN FC Part number Units per
assembly Description
11 6457 520A 10N8782 sub
10N9312
1 12X Long Run 5796 Attach
11 6446 520B 10N774 sub
19N9311
1 12X Short Run 5796 Attach
11 520D 10N8867 1 SPCN card
11
11
Levko Fattori IBM Slovenia 10
FC6446 - 12X Short Run 5796 Attach
This adapter provides the interface for attachment of the FC5796 I/O Drawer to a 12X
Channel loop. The adapter includes two 12X Channel connectors and is inserted into the
FC5796. This adapter does not include the repeater function and is intended to support
configurations where the host system and the FC5796 I/O drawers in the loop are located
in the same rack.
12X cables attached to this adapter have the following restrictions. Cables between this
adapter and a host system may not exceed 3.5 Meters in length. Cables between two I/O
drawers may not exceed 1.5 Meters if both I/O drawers include this Short Run adapter
FC6446. Cables between two I/O Drawers may not exceed 3.5 Meters if either of the I/O
drawers includes this Short Run adapter FC6446.
FC6457 - 12X Long Run 5796 Attach
This adapter provides the interface for attachment of the FC5796 I/O drawer to a 12X
channel loop. The adapter includes two 12X channel connectors and is inserted in the
FC5796. This adapter includes the repeater function and can support longer cable loops
allowing drawers to be located in adjacent racks.
12X cables up to 8 meters in length can be attached to this adapter.
The required 12X cables are ordered under a separate feature number.
"R SR" is used to represent the Short Range option... No repeaters. This is also identified
by the lighter cream coloring of the cable retention guide.
"R LR" is used to represent the Long Range option... Repeaters. Also identified by the
darker olive green coloring of the cable retention guide.
All system (CEC) connections are labeled "R LR".
Levko Fattori IBM Slovenia 11
R SR designates RIO - Short Range R LR designates RIO - Long Range Combination, Cream / Green color connector, Short Range (R SR)
Solid Green color connector, Long Range (R LR)
Levko Fattori IBM Slovenia 12
If Drawers are in the same Rack as the system unit: Cable length should be < 3.5 m FC 6446 in Drawers will be ok. Cables from drawer to drawer cannot be longer than 1.5m!
3.5M and you are ok with FC6446
Also drawer to drawer, if the drawers are together then you stay under 1.5 meter and
FC6446 is OK.
So if you daisy chain IO drawers that are all close together and you are in the same rack
as the 570 you
Levko Fattori IBM Slovenia 13
can use FC6446 on all.
IBM offers four 12X cable lengths
FC1829 0.6 meter
FC1830 1.5 meter
FC1840 3.0 meter
FC1834 8.0 meter
Cable feature Cable type Length Part number
1829 12x InfiniBand cable 0.6 m (2 ft.) 41V0226
1830 12x InfiniBand cable 1.5 m (5 ft.) 41V0227
1840 12x InfiniBand cable 3 m (9.8 ft.) 42V2132
1834 12x InfiniBand cable 8 m (26 ft.) 39J5642
Levko Fattori IBM Slovenia 14
Additional Method for recognize 12x, for case PMR: 27690,661,706.
In the HONE Intranet (http://ehone.ibm.com/), select Inventory Retrieval,
Select which inventory to retrieve:
Inventory type: Hardware Software Both
Country: FRANCE
Machine type: 9406 AS400 / IBM eServer
* Serial number: 65FBFC1
And SUBMIT
Save File as 65FBFC1.CFR
Start e-config
Levko Fattori IBM Slovenia 15
Select machine 65FBFC1.CFR
After some time a CFR report is created
Diagram is created
Levko Fattori IBM Slovenia 16
By selecting of PROPOSED
Levko Fattori IBM Slovenia 17
From Configuration the Customer have 5796 Expansion Drawers ( 17 pieces ) and in the Drawer they have a
6457 12X Long Run attach.
At the page 9 You can see CCIN, FC and P/N
Additional method is from HSM
SYSTEM EXPANSION UNIT 5796-001 65-3734C LB12 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB13 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB14 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB15 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB16 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB17 07P6949 U5796.001.653734C
BACKPLANE 520C 0D-8146037 PCI11D 07P6949 U5796.001.653734C-P1
HSL I/O BRIDGE 520C 0D-8146037 BC15 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC12 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI12D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC13 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI13D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC14 07P6949 U5796.001.653734C-P1
HSL I/O BRIDGE 520C 0D-8146037 BC16 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI14D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC15 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI15D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC16 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI16D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC17 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520A 1D-8037144 10N9312 U5796.001.653734C-P1-C7
SPCN CARD 520D 0D-8146171 10N8867 U5796.001.653734C-P1-C8
SYSTEM EXPANSION UNIT 5796-001 65-5129C LB06 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB07 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB08 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB09 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB10 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB11 07P6949 U5796.001.655129C
BACKPLANE 520C 0D-8142140 PCI05D 07P6949 U5796.001.655129C-P1
HSL I/O BRIDGE 520C 0D-8142140 BC09 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC06 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI06D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC07 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI07D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC08 07P6949 U5796.001.655129C-P1
HSL I/O BRIDGE 520C 0D-8142140 BC10 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI08D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC09 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI09D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC10 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI10D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC11 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520A 1D-8037108 10N9312 U5796.001.655129C-P1-C7
SPCN CARD 520D 0D-8142012 10N8867 U5796.001.655129C-P1-C8
In a case You will found some mistake, please let me inform.
In a case You would like to add something, please send to me and I will update this book.
LevkoFattori