• 8 Segment programmer
• Heater failure detection
• Current monitoring
• Internal timer
• Scrolling text messages
• Recipes
• Modbus comms
• Modbus SP retransmission
• Analogue retransmission
• Remote setpoint
• Help text
• Type approved to EN14597 TR
• Multi-language support(French, German, Spanishand Italian)
Temperature/Process ControllersSpecification Sheet
The innovative range of 3200 controllers offer precision control oftemperature and other process variables together with a host ofadvanced features not normally found in this class of controller.
The emphasis is on ease of use. A simple ‘Quick Start’ code is used toconfigure all the functions essential for controlling your process. Thisincludes input sensor type, measurement range, control options, andalarms, making ‘Out the Box’ operation truly achievable. In operatormode every parameter has a scrolling text message describing itsfunction and is available in English, German, French, Spanish or Italian.More advanced features are configured using iTools, a PC basedconfiguration wizard which is an easy to use and instructive guide to allthe functions in the controller.
Heater current monitoringA current transformer input provides display of the heater current and ahealth check on the load. Partial load failure, heater open circuit and SSRfaults are detected and displayed as scrolling alarm messages as well asproviding an alarm output. On the 3208 and 3204 a front panel ammeterdisplays the heater current.
Setpoint programmerHeat treatment profiles can be programmed using the 8-segmentprogrammer. Holdback, at the beginning of each segment can be usedto guarantee the soak periods. A digital event output can be triggered inany segment to initiate actions within the process.
Custom text messagingCustom messages can be created with iTools and downloaded to the3200 to display when an event, alarm or process condition occurs. Thisprovides the operator with good visibility of the status of the process.
Remote setpointAn option exists for the 3200 to have a Remote Analogue Input. This canbe either volts or mA and is used to allow the setpoint to be generatedby a master controller or PLC.
SERIES
3200
Eurotherm Part No. HA028600 Issue 8 March 2013 2 3200 Series Specification Sheet
RecipesUsing iTools, recipes can be created that may be used to changethe operating parameters of the 3200 simply by selecting a newrecipe using the 3200 HMI or digital input. This is very useful wheremultiple products are processed using the same controller butrequire different parameters to be set.
TimerAn internal timer is configurable as an interval timer, delay timer orto provide a soft start for hot runner control.
Setpoint retransmissionSending the setpoint or other parameters from the 3200 to slavedevices can be achieved either using conventional analoguecommunications or using Master Modbus communications. MasterModbus in the 3200 allows a broadcast of a single parameter tothe network.
A typical application is a setpoint being retransmitted to a numberof slave controllers in a multi-zone furnace.
Modbus communicationsAll units support both EIA232 and 2-wire EIA485 communicationsusing the Modbus protocol. The 3216 supports 4-wire EIA485.
Configuration adaptoriTools configuration to all 3200 controllers can be achieved byusing a configuration adaptor. It provides iTools with the ability tocommunicate with and configure devices without the need for anypower being connected.
iTools wizardUsed to simplify the set up of 3200 series controllers. The wizardguides the user through the configuration process with interactivehelp and graphical demonstrations of features.
SpecificationGeneralEnvironmental performance Temperature limits Operation: 0 to 55°C
Storage: –10 to 70°CHumidity limits Operation: 5 to 90% RH non condensing
Storage: 5 to 90% RH non condensingPanel sealing: IP65, Nema 4XShock: BS EN61010Vibration: 2g peak, 10 to 150HzAltitude: <2000 metresAtmospheres: Not suitable for use in explosive or
corrosive atmosphere
Electromagnetic compatibility (EMC) Emissions and immunity: BS EN61326
Electrical safety (BS EN61010): Installation cat. II; Pollution degree 2
INSTALLATION CATEGORY IIThe rated impulse voltage for equipment on nominal 230V mains is 2500V.
POLLUTION DEGREE 2Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation shall be expected.
EN14597 TR APPROVALRegistration Number TR1229.
Physical Dimensions: 3216: 48W X 48H X 90Dmm
3208: 48W X 96H X 90Dmm3204: 96W X 96H X 90Dmm32h8: 96W X 48H X 90Dmm
Weight: 3216: 250g3208: 350g3204: 420g32h8: 350g
Panel: Mounting Cut-out dimensions3216: 1/16 DIN 45W x 45Hmm 3208: 1/8 DIN 45W x 92Hmm3204: 1/4 DIN 92W x 92Hmm32h8: 1/8 DIN, horizontal 92W x 45Hmm
Panel depth: All: 101mm
Operator interface Type: LCD TN with backlightMain PV display: 4 digits, greenLower display
3216, 3208, 3204: 5 character starburst, green32h8: 9 character starburst, green
Status beacons: Units, outputs, alarms, active setpoint
Power requirements 3216: 100 to 240V ac, –15%, +10%,
48 to 62 Hz, max 6W24V ac, –15%, +10%. 24V dc, –15% +20% ±5% ripple voltage max 6W
3208, 32h8, 3204: 100 to 240Vac, –15%, +10%, 48 to 62 Hz, max 8W24V ac, –15%, +10%. 24V dc, –15% +20% ±5% ripple voltage max 8W
Approvals CE, cUL listed (file E57766), Gost, DIN 3440 (3216 only)Suitable for use in Nadcap and AMS2750D applications under SystemsAccuracy Test calibration conditions
Transmitter PSU (not 3216) Rating: 24V dc, >28mA, <33mAIsolation: 264V ac double insulated
CommunicationsSerial communications option Protocol: Modbus RTU slave
Modbus RTU Master broadcast (1 parameter)
Isolation: 264V ac, double insulatedTransmission standard: EIA232 or EIA485 (2-wire)
EIA485 (4-wire) on 3216 only
Process variable input
Calibration accuracy: <±0.25% of reading ±1LSD (Note 1)Sample rate: 4Hz (250ms)Isolation: 264V ac double insulation from the PSU
and communication
Resolution (µV): <0.5µV with 1.6 sec filterResolution (effective bits): >17 bitsLinearisation accuracy: < 0.1% of readingDrift with temperature: <50ppm (typical) <100ppm (worst case)Common mode rejection: 48-62Hz, >-120dbSeries mode rejection: 48-62Hz, >-93dB Input impedance: 100MΩCold junction compensation: >30:1 rejection of ambient changeExternal cold junction: Reference of 0°C Cold junction accuracy: <±1°C at 25°C ambientLinear(process) input range: –10 to 80mV, 0 to 10V with 100KΩ/806Ω
external divider moduleThermocouple types: K, J, N, R, S, B, L, T, C, custom download
(Note 2)Resistance thermometer types: 3-wire Pt100 DIN 43760Bulb current: 0.2mALead compensation: No error for 22Ω in all leadsInput filter: Off to 59.9sZero offset: User adjustable over full rangeUser calibration: 2-point gain & offset
AA relayType: Form C (changeover)Rating: Min 100mA@12V dc, max 2A@264V ac
resistive Functions: Control outputs, alarms, events
Current transformer inputInput range: 0-50mA rms, 48/62Hz. 10Ω burden
resistor fitted inside moduleCalibration accuracy: <1% of reading (Typical),
<4% of reading (Worst case)Isolation: By using external CTInput impedance: <20ΩMeasurement scaling: 10, 25, 50 or 100 AmpsFunctions: Partial load failure, SSR fault
Digital input (DigIn A/B, B not on 3216)Contact closure: Open >600Ω, closed <300ΩInput current: <13mAIsolation: None from PV or system
264V ac double insulated from PSU and communications
Functions: Includes alarm acknowledge, SP2 select, manual keylock, timer functions standby select, RSP select
Logic I/O moduleOutputRating: ON 12V dc@<44mA,
OFF <300mV@100µAIsolation: None from PV or system.
264V ac double insulated from PSU and communications
Functions: Control outputs, alarms, events
Digital input Contact closure: Open >500Ω, closed <150ΩIsolation: None from PV or system
264V ac double insulated from PSU and communications
Functions: Includes alarm acknowledge, SP2 select, manual, keylock, timer functions, standbyselect, RSP select
Relay output channelsType: Form A (normally open)Rating: Min 100mA@12V dc, max 2A@264V ac
resistive Functions: Control outputs, alarms, events
Triac outputRating: 0.75A (rms) 30 to 264V (rms) resistive
loadIsolation: 264V ac double insulatedFunctions: Control outputs, alarms, events
Analogue output (Note 3)
OP1, OP2Rating: 0-20mA into <500ΩAccuracy: ± (<1% of Reading + <100µA)Resolution: 13.5 bitsIsolation: 264V ac double insulated from PSU and
communicationsModule code C provides full 264V ac double isolated
Functions: Control outputs, retransmission
OP 3 (not on 3216) Rating: 0-20mA into <500ΩAccuracy: ±(<0.25% of Reading + <50µA)Resolution: 13.6 bitsIsolation: 264V ac double insulatedFunctions: Control outputs, retransmission
Remote setpoint inputCalibration accuracy: <±0.25% or reading ±1LSDSample rate: 4Hz (250ms)Isolation: 264V ac double insulation from
instrumentResolution: <0.5mV (for 0-10V) or <2µA (for 4-20mA)Resolution (effective bits): >14bitsDrift with temperature: <50ppm (typical) <150ppm (worst case)Common mode refection: 48-62Hz, >-120dBSeries mode rejection: 48-62Hz, >-90dBInput impedance: Voltage: 223KΩ and Current: 2R49Normal input range: 0 to 10V and 4 to 20mAMax input range: –1V to 11V and 3.36mA to 20.96mA
Software featuresControlNumber of loops: 1Loop update: 250msControl types: PID, ON/OFF, VPCooling types: Linear, fan, oil, waterModes: Auto, manual, standby, forced manualOvershoot inhibition: High, low
Alarms Number: 4Type: Absolute high & low, deviation high,
low or band, rate of changeLatching: Auto or manual latching, non-latching,
event onlyOutput assignment: Up to four conditions can be assigned
to one output
Other status outputs Functions: Including sensor break, manual mode,
timer status, loop break, heater diagnostics, program event
Output assignment: Up to four conditions can be assigned to one output
Setpoint programmer Program function: 1 program x 8 segments with 1 event
output (Note 4))
Start mode: Servo from PV or SPPower fail recovery: Continue at SP or Ramp back from PVGuaranteed soak: Inhibits dwell timing until PV within limits
Timer Modes Dwell when setpoint reached
Delayed control action, Soft start limits power below PV threshold
Current monitor Alarm types: Partial load failure, over current, SSR
short circuit, SSR open circuitIndication type: Numerical or ammeter
Custom messages Number: 15 scrolling text messagesNo of characters: 127 characters per message maxLanguages: English, German, French, Spanish, ItalianSelection: Active on any parameter status using
conditional command
Recipes Number: 5 recipes with 38 parametersSelection: HMI interface, communications or
digital IO
Notes
1. Calibration accuracy quoted over full ambient operating range and forall input linearisation types.
2. Contact Eurotherm for details of availability of custom downloads for alternative sensors.
3. Voltage putput can be achived by external adator.
4. By using recipes five SP programs can be stored.
Eurotherm Part No. HA028600 Issue 8 March 2013 3 3200 Series Specification Sheet
Eurotherm Part No. HA028600 Issue 8 March 2013 4 3200 Series Specification Sheet
3200 Accessories
X Not fittedR RelayA Dual relay
(From A-OP3 and OP4)
VH 85-264V acVL 24V ac or dc
CC Standard controllerCP Standard programmerVC Motorised valve controllerVP Motorised valve programmer
ENG EnglishFRA FrenchGER GermanSPA SpanishITA Italian
3216 48 x 48mm unit3208 48 x 96mm unit32h8 96 x 48mm horizontal unit3204 96 x 96mm unit
3216OP1 OP2
XXXX None fitted None fittedLXXX Logic None fittedLRXX Logic RelayRRXX Relay RelayLLXX Logic LogicLDXX Logic 0-20mADRXX 0-20mA RelayRCXX Relay Isolated 0-20mALCXX Logic Isolated 0-20mADCXX 0-20mA Isolated 0-20mANot available with Low Voltage PSUDDXX 0-20mA 0-20mALTXX Logic TriacTTXX Triac Triac3208/32h8/3204
OP1 OP2 OP3LRRX Logic Relay RelayRRRX Relay Relay RelayLRDX Logic Relay 0-20mARRDX Relay Relay 0-20mALLDX Logic Logic 0-20mALDDX Logic 0-20mA 0-20mARDRX Relay 0-20mA RelayDRDX 0-20mA Relay 0-20mANot available with Low Voltage PSULLRX Logic Logic RelayDDDX 0-20mA 0-20mA 0-20mALTRX Logic Triac RelayTTRX Triac Triac RelayLTDX Logic Triac 0-20mATDDX Triac 0-20mA 0-20mATTDX Triac Triac 0-20mA
G GreenS SilverW Washdown (not 32h8/04)
ENG EnglishFRA FrenchGER GermanSPA SpanishITA Italian
XXXXX StandardWL005 Extended
XXXXX NoneCERT1 Certificate of ConformityCERT2 Factory Calibration
Certificate
XXX None fittedXXL Logic inputXCL CT + Logic IP2XL RS232 Comms + Logic IP4XL 2-wire RS232 comms +
Logic IP2CL RS232 Comms CT + Logic IP4CL 2-wire RS232 Comms CT +
Logic IP
XXXXX None
XXXXX NoneRES250 250R resistor for 0-5V dc OPRES500 500R resistor for 0-10V dc OP
HA029714 Installation guideHA027986 Engineering manualSUB35/ACCESS/249R.1 2.49R Precision resistorCTR100000/000 10A Current transformerCTR200000/000 25A Current transformerCTR400000/000 50A Current transformerCTR500000/000 100A Current transformeriTools/None/3000CK Configuration clipSUB21/IV10 0-10V input adaptor
Function
Supply Voltage
Basic Product
2
1
1 2 3 4 5 6 7 8 9 10 11
Outputs3 AA Relay (OP4)4
Options Board5
Fascia Colour6
Product Language7
Warranty9
Certificates10
12
Manual Language8
Custom Label11
Specials and Accessories12
264V ac Double
264V ac Double
264V ac Double
Power
264V ac Double
0-20mAIsolated Modules
Relays and Triacs
PowerSupplyCircuits
Rectification
µP &systemcircuits
All logic inputs &O/Ps & non isolated
0-20mA O/P
CT Measurement
Micro mountedPV Input
Serial CommsRemote Setpoint
264V ac Double
264V ac Double
264V ac Double
264V ac Double
Power
264V ac Double
Analogue (OP3)output
Relays and Triacs
Serial CommsRemote Setpoint
PowerSupplyCircuits
Rectification
All logic inputs &O/Ps & non isolated
0-20mA O/P
Transmitter PSU
CT Measurement
Micro mountedPV Input
µP &systemcircuits
3216 Isolation3208/32h8/3204 Isolation
Hardware/options coding
Order codes
Eurotherm Part No. HA028600 Issue 8 March 2013 5 3200 Series Specification Sheet
Optional quick start code (Optional)
XX Not fitted1 10 Amps2 25 Amps5 50 Amps6 100 Amps
X UnconfiguredW Alarm acknowledgeM Manual selectR Timer/Prog RunL KeylockP Setpoint 2 selectT Timer/prog ResetU Remote SP selectV Recipe 2/1 selectA Remote up buttonB Remote down buttonG Time/prog Run/resetI Timer/prog HoldQ Standby select
ThermocoupleB Type BJ Type JK Type KL Type LN Type NR Type RS Type ST Type TC Custom/Type CRTDP Pt100LinearM 0-80mV2 0-20mA4 4-20mAX Unconfigured
X UnconfiguredT SetpointS Target setpointP Output power %R Time remainingE Elapsed time1 1st alarm setpointD Dwell/ramp - Time/targetC SP with output meterM SP with ammeterA Load ampsN None
Full PV RangeC Deg C full rangeF Deg F full rangeCentigrade0 0 to 100 deg C1 0 to 200 deg C2 0 to 400 deg C3 0 to 600 deg C4 0 to 800 deg C5 0 to 1000 deg C6 0 to 1200 deg C7 0 to 1400 deg C8 0 to 1600 deg C9 0 to 1800 deg CFahrenheitG 32 to 212 deg FH 32 to 392 deg F J 32 to 752 deg FK 32 to 1112 deg FL 32 to 1472 deg FM 32 to 1832 deg FN 32 to 2192 deg FP 32 to 2552 deg FR 32 to 2912 deg FT 32 to 3272 deg FX Unconfigured
Input Type
Setpoint Limits
3208/h8/04 only
3208/h8/04 only
2
1
1 2 3 4 5 6 7 8 9 10
CT Input Scaling 6
Dig Input A, Dig Input B7 - 8
Lower Display10
XX UnconfiguredRelay, DC, Triac or Logic outputsControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output Energised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output De-energised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation bandDC outputsControlH 4-20mA heatingC 4-20mA coolingJ 0-20mA heatingK 0-20mA coolingRetransmissionD 4-20mA setpointE 4-20mA Process valueF 4-20mA outputN 0-20mA setpointY 0-20mA Process valueZ 0-20mA outputLogic inputW Alarm acknowledgeM Manual selectR Timer/Prog RunL KeylockP Setpoint 2 selectT Timer/prog ResetU Remote SP selectV Recipe 2/1 selectA Remote up buttonB Remote down buttonG Time/prog Run/resetI Timer/prog HoldQ Standby select
Output 1 (OP1)3
XX UnconfiguredRelay, Triac or Logic outputsControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output Energised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output De-energised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation band
Output 2 (OP2)4
AA Relay (OP4)5
Output 3 (OP3)9
XX UnconfiguredRelay, DC, Triac or Logic outputsControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output Energised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output De-energised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation bandDC outputsControlH 4-20mA heatingC 4-20mA coolingJ 0-20mA heatingK 0-20mA coolingRetransmissionD 4-20mA setpointE 4-20mA Process valueF 4-20mA outputN 0-20mA setpointY 0-20mA Process valueZ 0-20mA output
XX UnconfiguredRelay, DC or Logic outputsControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output Energised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output De-energised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation bandDC outputsControlH 4-20mA heatingC 4-20mA coolingJ 0-20mA heatingK 0-20mA coolingRetransmissionD 4-20mA setpointE 4-20mA Process valueF 4-20mA outputN 0-20mA setpointY 0-20mA Process valueZ 0-20mA output
AA
AB
AC
HD
HE
HF
1A1B
2A2B
LBLC
CT
CLA
VI
V+
V-
3A3B
3C3D
LN
Dig in 2
COM
A (+)
B (–)
–
+
Dig in B
mV/V mA
RTD
CT
OP4
+
–
+
–
24V dc Transmitter supply
or withRemote Setpoint
or withRemote Setpoint
Line
Neutral
100 to 240V ac50/60Hz or
24V ac/dc
AA
AB
AC
VI
V+
V-
1A1B
2A2B
LN
Line
Neutral
100 to 240V ac50/60Hz or
24V ac/dc
COM
A(+)
B(–)
CT
mV/V mA
RTD
Dig in A
HD
HE
HF
CT
CLA
mA
V
HD
HE
HF
mA
V
HD
HE
HF
3208/32h8/3204
3216
CTCLAVIV+V-
3A3B3C3DLN
32h8 Orientation
OP1NO
C
+
–
+
–OP2
NO
C
+
–OP3
NO
C
NO
C
NC
OP4
NO
C
NC
+
–
+
–OP1
NO
C
+
–
+
–OP2
NO
C
Rear Terminals
3208 Panel cut-out 92mm (–0.0 +0.8) x 45mm (–0.0 +0.6)3204 Panel cut-out 92mm (–0.0 +0.8) x 92mm (–0.0 +0.8)
32043208
96mm48mm 90mm101mm
96m
m
32h8 Panel cut-out 45mm (–0.0 +0.6) x 92mm (–0.0 +0.8)3216 Panel cut-out 45mm (–0.0 +0.6) x 45mm (–0.0 +0.6)
48m
m
3216
48mm 90mm101mm
96mm
32h8
Mechanical Details
Eurotherm Part No. HA028600 Issue 8 March 2013 6 3200 Series Specification Sheet
Eurotherm Head OfficeFaraday Close, Durrington,Worthing, West Sussex, BN13 3PL
Worldwide Officeswww.eurotherm.com/global
Sales EnquiriesT +44 (01903) 695888F 0845 130 9936
General EnquiriesT +44 (01903) 268500F 0845 265982
Represented by:
© Copyright Eurotherm Limited 2013
Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris, EPower, EPack, nanodac, piccolo, Foxboro andWonderware are trademarks of Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners.
All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it bestored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates, without the priorwritten permission of Eurotherm Limited.
Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore bechanged without notice. The information in this document is given in good faith, but is intended for guidance only.
Eurotherm Limited will accept no responsibility for any losses arising from errors in this document.