what are emerging contaminants and why are we concerned · individual compounds. • no minimum...
TRANSCRIPT
![Page 1: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/1.jpg)
www.eatonanalytical.com
What are Emerging Contaminants and why are we Concerned
William Lipps CSO
Monrovia South Bend
![Page 2: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/2.jpg)
www.EurofinsUS.com/Env
William Lipps
• Chief Science Officer – Eurofins Eaton Analytical
• Monrovia CA
• South Bend Indiana
• ASTM D19 Chair, Fellow
• Standard Methods AWWA Editor and Part 4000 Coordinator
• Incoming SME ED Chair
• ANSI representative to ISO TC147 (water) SC2 (chemistry)
![Page 3: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/3.jpg)
www.EurofinsUS.com/Env
Some History
![Page 4: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/4.jpg)
Water testing before the EPA
4
Burning Barge On The Ohio River, May 1972William Strode / EPA
Outflow Pipe 6 of the Oxford Paper Company Will at Rumford
on the Androscoggin River 06/1973
Charles Steinhacker / EPA
Mills of the Brown Paper Company in Berlin, on the
Androscoggin River 06/1973
Charles Steinhacker / EPA
Prior to EPA – Conventional Pollutants such as BOD, COD, metals, pH, turbidity
No real trace organics testing at all
![Page 5: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/5.jpg)
Pre-EPA organics analysis involved solving mysteries – took weeks
5
Fish Kills
Taste and Odor
Credit to Larry H Keith for this and photos on
next few slides
![Page 6: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/6.jpg)
Large volumes of samples collected and extracted
6
![Page 7: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/7.jpg)
Data manually analyzed – no QA/QC
7
Ron Webb – capillary columnsPlotting and interpreting mass spectra by hand
![Page 8: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/8.jpg)
1975 report – 66 chemicals found in New Orleans water supply
8
• Newly formed EPA got sued
• Consent Decree 1976 – required EPA to:
• Develop methods• Develop sampling procedures• 65 pollutants• 21 industrial categories• In 15 months
![Page 9: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/9.jpg)
Some overlooked aspects of the consent decree
9
• “65 pollutants” – really thousands since some were classes rather than individual compounds.
• No minimum detection levels were specified.
• No standardized methods for collecting, preserving, or analyzing for thousands of chemicals at low levels in complex industrial waste waters were available.
• How do labs estimate costs for sampling and analysis for no defined list of analytes, no methods, or no defined limits?
Now 1912
![Page 10: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/10.jpg)
Priority Pollutants are born
10
• EPA made methods:• GCMS for organics• GC-ECD for pesticides• ICP or AA for metals• 10 ppb detection limit
• Specific compounds made list• Metals = “total”• Classes became – “total
phenolics”, “total cyanide”, aroclors
![Page 11: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/11.jpg)
We got 129 Priority Pollutants with defined methods
11
1. Metals2. Asbestos3. Total Cyanide4. Organochlorine Pesticides and PCBs5. Base Neutral and Acid Extractable Organics6. Purgeable Organics7. Total Phenols
“In the beginning there was water, and it got dirty” Bill Telliard, USEPA
![Page 12: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/12.jpg)
These 129 pollutants are still with us today
12
Different US EPA programs = same pollutants plus more
• SDWA = Primary, Secondary, UCMR, DBP, Radionuclides, Bacteria
• CWA = Priority Pollutants, radionuclides, nutrients, bacteria/viruses
• RCRA = Priority Pollutants, BTEX/GRO, explosives
![Page 13: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/13.jpg)
www.EurofinsUS.com/Env
Emerging Contaminants
![Page 14: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/14.jpg)
Other compounds that are not on a list are = Emerging Contaminants
14
• No regulation, maybe no method• Have been found in environment• May pass through drinking or wastewater
treatment
• Very similar to New Orleans study:• Classes with no fixed list• No “standardized methods”• No analytical standards (for many)
![Page 15: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/15.jpg)
Over years, talk of emerging contaminants but not much action
15
• Pharmaceutical and Personal Care Products (PPCP)
• Perchlorate, • Chromium VI, • 1,4-Dioxane• Dioxin• Microplastics• Unknown organics• The compounds that shall not be named (aka
PFAS)
![Page 16: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/16.jpg)
So what is the difference between now and then?
16
No consent decree
![Page 17: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/17.jpg)
www.EurofinsUS.com/Env
Pharmaceuticals and Personal Care Products
![Page 18: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/18.jpg)
18
Pharmaceutical and Personal Care Products (PPCP)
• Very diverse = thousands of compounds• Antibiotics• Hormones• Laundry and cleaning products• Cosmetics and sunscreen• Dietary supplements• Prescription and over the counter drugs• Illegal drugs
• Given to humans in large dose = what is effect on microorganisms (wastewater and ambient water)
![Page 19: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/19.jpg)
19
How can PPCP get into our water supplies?
IWMI 2017
![Page 20: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/20.jpg)
20
Example- Antibiotics affect bacteria in WWTP and ambient
• Antibiotics used -- Human and animal use• Not regulated for NPDES or SDWA
• Purpose of WWTP • Decrease organic waste• Remove nutrients
• WWTP uses bacteria
![Page 21: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/21.jpg)
21
Bacteria in the WWTP can develop into antibiotic resistant strains
https://www.sciencedirect.com/science/journal/00431354
Antibiotic resistant strains can be released
![Page 22: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/22.jpg)
22
Fish don’t need pills
https://aispantherpaper.wordpress.com/2018/04/30/what-are-superbugs-and-how-are-they-affecting-us/
Resistant bacteria
Food and/or drinking water
Antibiotics in water
![Page 23: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/23.jpg)
www.EurofinsUS.com/Env
What are the “approved” methods for PPCP?
• Method 539 – LCMSMS, finished drinking water, UCMR• Method 542 – LCMSMS, finished drinking water, UCMR• Standard Methods 6810
• Not regulated by SDWA – no official methods
• EPA 1694 – LCMSMS, non-potable water, bio-solids• Standard Methods 6810
• Not listed in 40 CFR Part 136
Proprietary methods
![Page 24: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/24.jpg)
24
Unlike the priority pollutant solution, PPCP analysis lacks:
• A specific list of analytes
• Approved methods
• Regulations requiring monitoring
• Clear adverse health risk (SDWA)
![Page 25: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/25.jpg)
www.EurofinsUS.com/Env
Perchlorate
![Page 26: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/26.jpg)
Perchlorate, another big boom
26
• Highly oxidized polyatomic anion• Naturally occurring – arid • Man-made• Soluble and mobile
![Page 27: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/27.jpg)
First measured in UCMR1
27
• 164 of 3865 systems > 4 ppb
• 26 States and 2 Territories
• Mean = 9.85 ppb• Median = 6.40 ppb
![Page 28: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/28.jpg)
Perchlorate regulations by States
28
• California proposed 1 ppb
• Now at 6 ppb with 4 ppb action level
• Most States 1 – 6 ppb
![Page 29: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/29.jpg)
Perchlorate difficult to remove by traditional treatment
29
• Ion Exchange
• Reverse Osmosis
• Biological Reduction
• Biological Activated Carbon
• Granular Activated Carbon
![Page 30: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/30.jpg)
Analyze Perchlorate to verify removal from Drinking water
30
EPA method 314.0 Ion Chromatography (2-4 ppb MRL)
EPA Method 331 LCMSMS (0.5 – 2 ppb MRL)
![Page 31: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/31.jpg)
No federal MCL as of 2019, however, regulation is proposed
31
A consent decree entered by the U.S. District Court for the Southern District of New York states that EPA shall propose a national primary drinking water regulation (NPDWR) with a proposed Maximum Contaminant Level Goal (MCLG) for perchlorate in drinking water no later than 10/31/18 and finalize a MCLG and NPDWR for perchlorate in drinking water no later than 12/19/19.
![Page 32: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/32.jpg)
www.EurofinsUS.com/Env
Micro-Plastics
![Page 33: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/33.jpg)
Microplastics in water, and what it could mean
33
• Plastics debris and microplastics occur worldwide• Beaches• Surface water• Wastewater• Drinking water• Food• Inside fish, birds, mammals
![Page 34: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/34.jpg)
Where do micro-plastics come from
34
• Primary• Health and beauty products• Toothpaste• Spills
• Secondary• Larger products become smaller
• Bottles• Bags• Carpet
• Size < 5 mm
![Page 35: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/35.jpg)
There is about 322 million tons plastic manufactured per year
35
Polypropylene (PP)
Low Density Polyethylene
(LDPE)
High Density Polyethylene
(HDPE)Polyvinyl
Chloride (PVC)
Polyethylene Terephthalate
(PET)
Polystyrene (PS)
Polyurethane (PUR)
Other
![Page 36: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/36.jpg)
How much plastic is released into the environment?
36
Degradation fragmentation into smaller particles
Do not dissolve
Are not biodegradable
No one really knows how much of the 322 Million tons per year is released
![Page 37: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/37.jpg)
Once plastic is released it weathers to micro-plastic
37
• Wave activity• Abrasion• UV irradiation• Microbes
• Systematically break down into smaller particles• Higher surface area• Greater sorption capacity• Different shapes
![Page 38: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/38.jpg)
Microplastics in the POTW
38
• Effluent ~ 1000 particles/L
• Removal ~ 90%• < 10 µm not removed• 80 % of fibers NOT removed (shape matters)
• Most end up in bio-solids (land farmed?)
![Page 39: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/39.jpg)
Microplastics in ambient water and source water
39
• Higher in coastal and industrialized areas• Vertical distribution counterintuitive
• Larger, more buoyant, on top• Smaller (< 100 µm) particles deeper• Varies on stream conditions, particle shape
![Page 40: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/40.jpg)
Efforts to standardize methods for Microplastics
40
As always – there are proprietary methods
![Page 41: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/41.jpg)
How to sample varies per sample type, so does processing
41
![Page 42: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/42.jpg)
In our own study - Everyone Used Their Own Bottles
42
![Page 43: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/43.jpg)
The whole sample as received filtered Special filtration setup in
polymer dust free lab facility.
Specially designed stainless steel filtration apparatus
43
![Page 44: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/44.jpg)
Even drinking water needs prep!
44
total samples samples coloring filters
21% of samples resulted in colored filters. Occurred in most countries.
![Page 45: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/45.jpg)
Most challenging aspect of micro-plastic analysis is preparation
45
• Sample preparation “breaks” particles
Sampling
Extraction
Selective Digestion
Isolation
Analysis
![Page 46: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/46.jpg)
Once preparation is complete, ID plastics using FTIR microscope
46
![Page 47: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/47.jpg)
Analysis of Micro-plastics, using an IR-Microscope
47
80010001200140016001800200024002800320036004000cm-1
AbsMeasurement samplePolystyrene (PS)
Count particles, determine ID, Size and shape
Can only estimate mass
![Page 48: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/48.jpg)
Alternatively - Analysis of Micro-plastics, using Pyrolysis GCMS
48
https://doi.org/10.1016/B978-0-08-100116-5.00017-X
Mass / Volume measurement
ID polymer
Don’t know:• # particles• Size• Shape
![Page 49: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/49.jpg)
Efforts to standardize methods for Microplastics
49
WK67563 Collection of Wastewater Samples for the Identification and Quantification of Microplastic Particles
WK67564 Preparation of Wastewater Samples Allowing the Identification and Quantification of Microplastic Particles using Raman and FTIR Microscopy
WK67565 Spectroscopic Identification and Quantification of Microplastic Particles in Water Using Raman and FTIR Spectroscopy
WK67788 Identification of Microplastic Particles and Fibers in Water using Pyrolysis‐GC/MS
![Page 50: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/50.jpg)
www.EurofinsUS.com/Env
That other stuff
![Page 51: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/51.jpg)
The compounds that shall not be named (aka – the other plastics)
51
Per and polyfluorinated Alkyl Substances - PFAS
![Page 52: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/52.jpg)
What are PFAS, really?
52
• Man-made• Surfactant or “fatty acid”• Carbon backbone – fluorine instead of
hydrogen• Very inert• Residual and persistent• Still in use – thousands of products
![Page 53: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/53.jpg)
Let’s compare PFAS to hydrocarbons - surfactants
53
Anionic detergent(Linear octyl sulfonate)
PerfluoroOctyl Sulfonate (PFOS)
![Page 54: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/54.jpg)
Let’s compare PFAS to hydrocarbons – fatty acids
54
Fatty Acid(Octanoic Acid)
PerfluoroOctanoic acid (PFOA)
![Page 55: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/55.jpg)
Definition of what PFAS really is
55
• Linear or branched chain organic compounds• Chain terminated with polar “head”• Negative charged “head” = anion• Carbon – Hydrogen replaced by Carbon – Fluorine• C-F bond VERY stable• Oil/water resistant “tail” and polar “head”• Fewer carbons = more water soluble• Long chains = stick to stuff (soil, GAC, surfaces)• Buoyant (like plastics)
![Page 56: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/56.jpg)
The magical carbon-fluorine bond
56
• C-F bond = one of strongest in organic chemistry• High thermal stability• Fluorine “shields” carbon from oxygen, etc.
• Think Teflon™
![Page 57: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/57.jpg)
The difference between per and poly
57
• Perfluorinated – every carbon (except head) surrounded by a fluorine
• Polyfluorinated – one or more carbon not surrounded by fluorine, or a break in the chain
![Page 58: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/58.jpg)
Naming conventions of PFAS
58
• Perfluorinated Functional groups (heads)
• Carboxylic acids (R-COOH) Surfactants (A)• Sulfonic Acids (RSO3H) Surfactants (S)• Sulfonamides (R-SO2NH2) Raw material or
intermediate
• Polyfluorinated Functional Groups• Fluorotelemer alcohols (R-CH2CH2OH) Raw
material• Fluorotelemer sulfonic acid (R-CH2CH2SO3H)
Surfactant• Fluorotelemer carboxylic acid (R-CH2COOH)
Intermediate
• 4 carbons – Buta (B)• 5 carbons - Penta (Pe)• 6 carbons - Hexa (Hx)• 7 carbons – Hepta (Hp)• 8 carbons – Octa (O)
Perfluorooctanoic acid (PFOA)
Perfluorooctane sulfonate (PFOS)
![Page 59: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/59.jpg)
Treating PFAS out of your water, not your average kind of bear
59
• Surfactants and grease do not behave like pesticides, normal organics
• Grease traps, oil/water separators
• Bugs – BOD removal
Fatty Acid = food
![Page 60: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/60.jpg)
PFAS behaves like oil and surfactants, but are inert
60
Micelles Float on surface
They are not “dissolved” in water, either coagulate, float, or stick to sides
![Page 61: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/61.jpg)
Bugs cannot eat PFAS
61
![Page 62: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/62.jpg)
The smaller chains are water soluble
62
https://www.researchgate.net/figure/Structures-of-major-perfluoralkyl-substances-PFBA-perfluorobutanoic-acid-PFPeA_fig1_316313698
![Page 63: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/63.jpg)
Carbon will clean some, but not all
63
PFBA about same PFOS about 90% removal
![Page 64: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/64.jpg)
The laboratory/regulatory predicament = which ones to test?
• 2 (PFOA & PFOS)?
• 6 UCMR3 compounds?
• 12 or all 14 EPA 537 compounds or 18 537.1 compounds?
• 21 compounds (NYDEC, etc.)?
• 24 or more compounds (DOD, NHDES, MIDEQ, EPA, ASTM, etc.)?
• GenX, ADONA, etc.?
64
![Page 65: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/65.jpg)
Should we look at all EPA 537, UCMR list, or just PFOA and PFOS?
Compound Acronym CarbonPerfluorobutanesulfonic acid (UCMR3) PFBS C4
Perfluorohexanesulfonic acid (UCMR3) PFHxS C6
Perfluorooctanesulfonic acid (UCMR3 and HA) PFOS C8
Perfluorohexanoic acid PFHxA C6
Perfluoroheptanoic acid (UCMR3) PFHpA C7
Perfluorooctanoic acid (UCMR3 and HA) PFOA C8
Perfluorononanoic acid (UCMR3) PFNA C9
Perfluorodecanoic acid PFDA C10
Perfluoroundecanoic acid PFUnA C11
Perfluorododecanoic acid PFDoA C12
Perfluorotridecanoic acid PFTrDA C13
Perfluorotetradecanoic acid PFTeDA C14
N-methyl Perfluorooctanesulfonamidoacetic acid NMeFOSAA C11
N-ethyl Perfluorooctanesulfonamidoacetic acid NEtFOSAA C1265
![Page 66: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/66.jpg)
Should we add the 537.1 analytes?
Compound Acronym Carbonhexafluoropropylene oxide dimer acid (HFPO-DA) GenX C3
11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid 11Cl-PF3OUdS C10
9-chlorohexadecafluoro-3-oxanone-1-sulfonic acid 9Cl-PF3ONS C8
4,8-dioxa-3H-perfluorononanoic acid ADONA C7
66
![Page 67: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/67.jpg)
Or our In-house Test that includes all EPA 537 compounds
Compound Acronym MRL (n/L)
Perfluorobutanesulfonic acid PFBS 2.0
Perfluorohexanesulfonic acid PFHxS 2.0
Perfluorooctanesulfonic acid PFOS 2.0
Perfluorohexanoic acid PFHxA 2.0
Perfluoroheptanoic acid PFHpA 2.0
Perfluorooctanoic acid PFOA 2.0
Perfluorononanoic acid PFNA 2.0
Perfluorodecanoic acid PFDA 2.0
Perfluoroundecanoic acid PFUnA 2.0
Perfluorododecanoic acid PFDoA 2.0
Perfluorotridecanoic acid PFTrDA 2.0
Perfluorotetradecanoic acid PFTeDA 2.0
N-methyl Perfluorooctanesulfonamidoacetic acid NMeFOSAA 2.0
N-ethyl Perfluorooctanesulfonamidoacetic acid NEtFOSAA 2.067
![Page 68: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/68.jpg)
Plus some extra for a total of 31
Compound Acronym MRL (n/L)
3 More Perfluoroalkylcarboxylic Acids
Perfluorobutanoic acid (C4) PFBA 5.0
Perfluoropentanoic acid (C5) PFPeA 2.0
Perfluorohexadecanoic acid (C16) PFHxDA 2.0
5 More Perfluoroalkylsulfonic Acids
Perfluoropentanesulfonic acid (C5) PFPeS 2.0
Perfluoroheptanesulfonic acid (C7) PFHpS 2.0
Perfluorononanesulfonic acid (C9) PFNS 2.0
Perfluorodecanesulfonic acid (C10) PFDS 2.0
Perfluorododecanesulfonic acid (C12) PFDoS 2.0
68
![Page 69: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/69.jpg)
In-house Test: 31 Extra (Cont’d)
Compound Acronym MRL (n/L)
5 More Perfluoroalkylsulfonamides
Perfluorooctane sulfonamide PFOSA 2.0
N-methylperfluorooctane sulfonamide NMeFOSA 2.0
N-ethylperfluorooctane sulfonamide NEtFOSA 2.0
N-methylperfluorooctane sulfonamidoethanol NMeFOSE 2.0
N-ethylperfluorooctane sulfonamidoethanol NEtFOSE 2.0
4 Fluorotelomer Sulfonic Acids
4:2 Fluorotelomer sulfonic acid 4:2 FTS 2.0
6:2 Fluorotelomer sulfonic acid 6:2 FTS 2.0
8:2 Fluorotelomer sulfonic acid 8:2 FTS 2.0
10:2 Fluorotelomer sulfonic acid 10:2 FTS 2.069
![Page 70: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/70.jpg)
In-house Test: 31 Extra (Cont’d)
Compound Acronym MRL (n/L)
8 Perfluoroalkyl Ether Carboxylic Acids and Others
GenX --- 5.0
ADONA --- 2.0
F-53B Major --- 2.0
F-53B Minor --- 2.0
Perfluoro-4-methoxybutanoic acid PFMOBA 5.0
Perfluoro-3-methoxypropanoic acid PFMOPrA 5.0
Perfluoro-2-methoxyethoxyacetic acid PFMOEOAA 5.0
Perfluoro-4-isopropoxybutanoic acid PFIpOBA 5.0
70
![Page 71: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/71.jpg)
In-house Test: 31 Extra (Cont’d)
Compound Acronym MRL (n/L)
6 Non-Target Perfluoroalkyl Ether Carboxylic Acids and Others
Perfluoro-2-methoxyacetic acid PFMOAA ~ 5
Perfluoro (3,5-dioxahexanoic) acid PFO2HxA ~ 5
Perfluoro (3,5,7-trioxaoctanoic) acid PFO3OA ~ 5
Perfluoro (3,5,7,9-tetraoxadecanoic) acid PFO4DA ~ 5
Nafion Byproduct 1 Nafion BP1 ~ 5
Nafion Byproduct 2 Nafion BP2 ~ 5
71
![Page 72: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/72.jpg)
In Absence of PFAS “regulation” Eurofins Eaton does-
EPA 537 and 537.1 for Drinking Water
• Stick to our guns on following methods
In-House methods for non-potable water
• Additional compounds and different SPE
In-House methods for Soil and DoD (LLE and/or TA)
72
![Page 73: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/73.jpg)
New and coming PFAS methods
ASTM D7979 (water) to SW846 method 8327
• Method 3512 for Extraction
ASTM D7968 (soil) to SW846 method 8329
• Method 3551 for Extraction
SW846 (soil and tissue) as method 8328
• Isotope dilution
• Carbon Cleanup (DoD)
73
![Page 74: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/74.jpg)
Potential existing PFAS methods
Total Oxidizable Precursor
Measures before and after oxidation
Increase assumes pieces “broken off” larger chains
74
![Page 75: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/75.jpg)
LC/MS/MS is targeted analysis, but we can look for unknowns
• Use EPA 537.1 for SDWA monitoring - Eaton
• Targeted list
• Use Eurofins Eaton High Resolution in house method for discovery of unknowns
75
![Page 76: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/76.jpg)
Cautions on existing PFAS data
• Only EPA 537.1 and ASTM/New EPA methods are “standardized”
• Lab modified methods may not compare between labs
• What were the modifications?
• Are peaks chromatographically resolved?
• Is the whole bottle extracted?
• “Hits” could be sampling contamination
76
![Page 77: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/77.jpg)
Recommendations• Use a Method 537.1 certified lab for drinking water
analysis.
• Use their bottles/preservatives
• Use our “high resolution” methods for discovery of unknowns.
• Make sure lab is “qualified” to modify methods.
• Eaton routinely collaborates with EPA, ASTM, and Standard Methods to make new methods.
77
![Page 78: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/78.jpg)
Conclusions• There will always be CECs
• CECs need standardized methods for sampling and analysis
• With standardized methods you can set limits.
• With standardized methods and limits you can determine BAT for removal.
• Eaton can help you test for CECs.
78
![Page 79: What are Emerging Contaminants and why are we Concerned · individual compounds. • No minimum detection levels were specified. • No standardized methods for collecting, preserving,](https://reader033.vdocument.in/reader033/viewer/2022041610/5e36db25465c1d61fc4dd232/html5/thumbnails/79.jpg)
Eurofins Eaton Analytical• has analyzed over 10,000 samples from approximately 1800 public water
system customers during the 2013-2015 UCMR3 monitoring period • since then continues to analyze even more comprehensive PFAS lists for
hundreds of clients across the nation. • the only laboratory in California that has been uploading state monitoring
data below the UCMR3 limits (MRL = 2 – 2.5 ng/L) • the first laboratory to seek California accreditation for PFAS analysis in
drinking water. • With lower limits, we are able to provide you trusted and accurate data
to demonstrate compliance with the new notification levels.