Paints Sheet products Fabrics Textile products Canopies Grounding Electro Measurement Prices YSHIELD GmbH & Co. KG, Am Schulplatz 2, 94099 Ruhstorf, Germany Phone: 0049-8531-31713-0, Email: [email protected], Web: www.yshield.com 60 YSHIELD® TBL - Bedding (HF) Avigation Military Measurement to ASTM D4935-10 30 MHz 18 GHz 1 GHz 10 GHz 100 MHz GSM 1800 GSM 900 LTE UMTS WLan LTE WiMAX DVB-T TETRA DVB-T Radar RADIO RADAR WLan WLan Radar LTE Radio link TV TV 70 cm TV CB RADIO 2 m T-DAB © YSHIELD GmbH & Co. KG Shielding fabric STEEL-GRAY -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 Characteristics Shielding bedding made from Steel-Gray for the shielding of high-frequency radiation (HF). The bedding set includes a sheet and a duvet cover. The sheet is made of Steel-Gray and can be coverd with a common sheet if required. The duvet cover is sewed two-sided: With the Steel-Gray side (gray fabric) used downwards for a better shielding, as the shielding fabrics will lay on top of each other. With the cotton fabric side (white fabric) used downwards with a decreased shielding but less scratchy. The set is not including a pillow case, this is not necessary anyway because of the incluced sheet. The fabric Steel-Gray was chosen as it is, due to it´s stain- less steel threats, considerably durable and more stable even with strong movement, then fabrics with silver threats would be. On the skin Steel-Gray feels a bit like a scratchy woolen sweater. Without pajama on this could bother you. Application This bedding is a cheap alterna- tive to canopies. Technical data Size sheet: 240 cm x 140 cm Size duvet cover: 200 cm x 135 cm Attenuation: 35 dB Raw materials: 40 % cotton, 30 % polyester, 30 % stainless steel Color: Gray, white Grounding To shield low frequency electri- cal fields this bedding could be grounded. You need: 2 x GS, 1 x GP, 1 x GC100, 1x GC500. Because of the cables in your bed a grounding is not advised. Screening attenuation The screening attenuation is regularly tested in our own EMC laboratory. We have measurement setups due to the following standards: ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07 . Please find the test report at our homepage directly on the product page. Care Gentle cycle at 30°C Iron without steam at degree 1 No drying in tumble dryers No bleaching No chemical dry-cleaning Cleaning with our special washing detergent TEXCARE. No handwashing! For allergy suf- ferers: Every new fabric smells, wash before its first usage!

Upload: others

Post on 04-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: YSHIELD · 2017-06-23 · network analyzer Rohde & Schwarz ZNB20 with 140 dB dynamic range up to 20 GHz. The antenna for ASTM D4935-10 are modifi ed TEM-cells, that can measure even

Pain

tsSh

eet p

rodu

cts

Fabr

ics

Text

ile p

rodu

cts

Cano

pies

Gro

undi

ngEl

ectr

oM

easu

rem

ent

Pric

esYSHIELD GmbH & Co. KG, Am Schulplatz 2, 94099 Ruhstorf, GermanyPhone: 0049-8531-31713-0, Email: [email protected], Web: www.yshield.com

60YSHIELD®TBL - Bedding (HF)

Messprotokoll Schirmdämpfung Measurement report screening attenuation

Phone: 0049-8531-31713-0Fax: 0049-8531-31713-5Email: [email protected]: www.yshield.com

EMR - PROTECTIONYSHIELD

YSHIELD GmbH & Co. KGAm Schulplatz 294099 RuhstorfGERMANY

Avi

gati

onM

ilita

ry

Measurement to ASTM D4935-1030 MHz 18 GHz 1 GHz 10 GHz100 MHz

GSM

180

0

GSM

900LT

E

UM

TSW

Lan

LTE

WiM

AX

DV

B-T

TETR

A

DV

B-T

Rada

r

RAD

IO

RAD

AR

WLa

n

WLa

nRa

dar

LTE

Radi

o lin

k

TV TV

70 c

m TV

CB R

AD

IO 2 m

T-D

AB

© YSHIELD GmbH & Co. KG

KonformitätDiese Messung der Schirmdämpfung elektromagnetischer Felder von 30 MHz bis 18 GHz wurde in Übereinstimmung mit dem Standard ASTM D4935-10 durchgeführt.

Ort der MessungSchon seit Jahren lassen wir die Schirmdämpfung nicht mehr von externen Laboren durchführen. Wir haben ein professionelles EMV-Labor nach gängigen etablierten Standards, wie z.B. ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07, etc. direkt bei uns im Haus.

Das hat für uns viele Vorteile: Unsere Produkte werden nicht nur einmalig getestet, zur Qualitätssicherung vermessen wir jede Charge. Und selbstverständlich brauchen wir das Labor zur Entwicklung unserer eigenen Produkte.

MessaufbauAls Messgerät verwenden wir den professionellen Vektor-Netzwerkanalysator Rohde & Schwarz ZNB20 mit einer Messdynamik von 140 dB bis zu 20 GHz.

Als Antenne für ASTM D4935-10 verwenden wir modifi zierte TEM-Zellen, die selbst kleine Muster bis hinunter zu 30 MHz im Fernfeld messen können. Die Muster werden mit radialer Polarisation gemessen (alle Richtungen, nicht nur horizontal oder vertikal), was der Realität am nächsten kommt. Alle elektrisch leitfähigen und dünnen Muster können mit diesen Zellen perfekt vermessen werden.

ConformityThis measurement of the screening attenuation of electromagnetic waves from 30 MHz to 18 GHz was done in conformity with standard ASTM D4935-10.

Location of measurementAlready since many years, the confi rmation of attenuation is no longer carried out through external consultants. We have a professional EMC-laboratory for any established engineer standards, as ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07, etc. at our disposal in-house.

We take many advantages of this: Our goods are not only tested by a survey once, as for the reason of quality managment each charge is measured again. Of course, we do need our laboratory for the development of own products.

Measurement setupThe instrument of measure is a professional vector network analyzer Rohde & Schwarz ZNB20 with 140 dB dynamic range up to 20 GHz.

The antenna for ASTM D4935-10 are modifi ed TEM-cells, that can measure even small samples down to 30 MHz in the far fi eld. The samples are measured with radial polarisation (all directions, not only horizontal or vertical only), what matches the reality most probably. All electrically conductive and thin samples can be measured perfectly with these cells.

Shielding fabric STEEL-GRAY

1/28/2014 10:18:22 AM

1311.6010K62-101470-WC

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Smo 1

Ch1 Start 30 MHz Pwr 8 dBm Bw 10 Hz Stop 18 GHz

1E+8 1E+9 1.8E+10

-90

-80

-70

-60

-50

-40

-30

-20

-10

-100

0

M1

0 dBM1 Trc1 1.000000 GHz -35.8312 dB

MaterialAbschirmstoff / Shielding fabric STEEL-GRAY

3/10/2014 8:19:53 PM

1311.6010K62-101470-WC

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

Ch1 Start 30 MHz Pwr 8 dBm Bw 10 Hz Stop 18 GHz

1E+8 1E+9 1.8E+10

-90

-80

-70

-60

-50

-40

-30

-20

-10

-100

0

M1

0 dBM1 Trc1 1.000000 GHz -50.0077 dB

Schirmung einlagig / Screening one-layer

Schirmung zweilagig /Screening two-layer

-10

-20

-30

-40

-50

-60

-70

-80

-90

-100

Characteristics

Shielding bedding made from Steel-Gray for the shielding of high-frequency radiation (HF).

The bedding set includes a sheet and a duvet cover. The sheet is made of Steel-Gray and can be coverd with a common sheet if required. The duvet cover is sewed two-sided: With the Steel-Gray side (gray fabric) used downwards for a better shielding, as the shielding fabrics will lay on top of each other. With the cotton fabric side (white fabric) used downwards with a decreased shielding but less scratchy. The set is not including a pillow case, this is not necessary anyway because of the incluced sheet.

The fabric Steel-Gray was chosen as it is, due to it´s stain-less steel threats, considerably durable and more stable even with strong movement, then fabrics with silver threats would be. On the skin Steel-Gray feels a bit like a scratchy woolen sweater. Without pajama on this could bother you.

Application

This bedding is a cheap alterna-tive to canopies.

Technical data

● Size sheet: 240 cm x 140 cm

● Size duvet cover: 200 cm x 135 cm

● Attenuation: 35 dB ● Raw materials: 40 % cotton,

30 % polyester, 30 % stainless steel

● Color: Gray, white

Grounding

To shield low frequency electri-cal fields this bedding could be grounded. You need: 2 x GS, 1 x GP, 1 x GC100, 1x GC500. Because of the cables in your bed a grounding is not advised.

Screening attenuation

The screening attenuation is regularly tested in our own EMC laboratory. We have measurement setups due to the following standards: ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07. Please find the test report at our homepage directly on the product page.

Care

Gentle cycle at 30°C

Iron without steam at degree 1

No drying in tumble dryers

No bleaching

No chemicaldry-cleaning

Cleaning with our special washing detergent TEXCARE. No handwashing! For allergy suf-ferers: Every new fabric smells, wash before its first usage!

Page 2: YSHIELD · 2017-06-23 · network analyzer Rohde & Schwarz ZNB20 with 140 dB dynamic range up to 20 GHz. The antenna for ASTM D4935-10 are modifi ed TEM-cells, that can measure even

Messprotokoll Schirmdämpfung Measurement report screening attenuation

Phone: 0049-8531-31713-0Fax: 0049-8531-31713-5Email: [email protected]: www.yshield.com

EMR - PROTECTIONYSHIELD

YSHIELD GmbH & Co. KGAm Schulplatz 294099 RuhstorfGERMANY

Avi

gati

onM

ilita

ry

Measurement to ASTM D4935-1030 MHz 18 GHz 1 GHz 10 GHz100 MHz

GSM

180

0

GSM

900LT

E

UM

TSW

Lan

LTE

WiM

AX

DV

B-T

TETR

A

DV

B-T

Rada

r

RAD

IO

RAD

AR

WLa

n

WLa

nRa

dar

LTE

Radi

o lin

k

TV TV

70 c

m TV

CB R

AD

IO 2 m

T-D

AB

© YSHIELD GmbH & Co. KG

KonformitätDiese Messung der Schirmdämpfung elektromagnetischer Felder von 30 MHz bis 18 GHz wurde in Übereinstimmung mit dem Standard ASTM D4935-10 durchgeführt.

Ort der MessungSchon seit Jahren lassen wir die Schirmdämpfung nicht mehr von externen Laboren durchführen. Wir haben ein professionelles EMV-Labor nach gängigen etablierten Standards, wie z.B. ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07, etc. direkt bei uns im Haus.

Das hat für uns viele Vorteile: Unsere Produkte werden nicht nur einmalig getestet, zur Qualitätssicherung vermessen wir jede Charge. Und selbstverständlich brauchen wir das Labor zur Entwicklung unserer eigenen Produkte.

MessaufbauAls Messgerät verwenden wir den professionellen Vektor-Netzwerkanalysator Rohde & Schwarz ZNB20 mit einer Messdynamik von 140 dB bis zu 20 GHz.

Als Antenne für ASTM D4935-10 verwenden wir modifizierte TEM-Zellen, die selbst kleine Muster bis hinunter zu 30 MHz im Fernfeld messen können. Die Muster werden mit radialer Polarisation gemessen (alle Richtungen, nicht nur horizontal oder vertikal), was der Realität am nächsten kommt. Alle elektrisch leitfähigen und dünnen Muster können mit diesen Zellen perfekt vermessen werden.

ConformityThis measurement of the screening attenuation of electromagnetic waves from 30 MHz to 18 GHz was done in conformity with standard ASTM D4935-10.

Location of measurementAlready since many years, the confirmation of attenuation is no longer carried out through external consultants. We have a professional EMC-laboratory for any established engineer standards, as ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07, etc. at our disposal in-house.

We take many advantages of this: Our goods are not only tested by a survey once, as for the reason of quality managment each charge is measured again. Of course, we do need our laboratory for the development of own products.

Measurement setupThe instrument of measure is a professional vector network analyzer Rohde & Schwarz ZNB20 with 140 dB dynamic range up to 20 GHz.

The antenna for ASTM D4935-10 are modified TEM-cells, that can measure even small samples down to 30 MHz in the far field. The samples are measured with radial polarisation (all directions, not only horizontal or vertical only), what matches the reality most probably. All electrically conductive and thin samples can be measured perfectly with these cells.

Shielding fabric STEEL-GRAY

1/28/2014 10:18:22 AM

1311.6010K62-101470-WC

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Smo 1

Ch1 Start 30 MHz Pwr 8 dBm Bw 10 Hz Stop 18 GHz

1E+8 1E+9 1.8E+10

-90

-80

-70

-60

-50

-40

-30

-20

-10

-100

0

M1

0 dBM1 Trc1 1.000000 GHz -35.8312 dB

MaterialAbschirmstoff / Shielding fabric STEEL-GRAY

3/10/2014 8:19:53 PM

1311.6010K62-101470-WC

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

Ch1 Start 30 MHz Pwr 8 dBm Bw 10 Hz Stop 18 GHz

1E+8 1E+9 1.8E+10

-90

-80

-70

-60

-50

-40

-30

-20

-10

-100

0

M1

0 dBM1 Trc1 1.000000 GHz -50.0077 dB

Schirmung einlagig / Screening one-layer

Schirmung zweilagig /Screening two-layer

-10

-20

-30

-40

-50

-60

-70

-80

-90

-100