zsmg_0039 hub-karang tengah
DESCRIPTION
iiiiTRANSCRIPT
![Page 1: ZSMG_0039 HUB-Karang Tengah](https://reader036.vdocument.in/reader036/viewer/2022082709/55cf9297550346f57b97ced3/html5/thumbnails/1.jpg)
Colocation ApplicationToday's Date 19-Apr-2023
Colo Application Date 19-Apr-2023
Revision 0
IBS Site ID Island Province CitySMG_01N020 Java Central Java Semarang
Latitude (Decimal/DMS) Longitude (Decimal/DMS) Site Type Tower Type-6.9261 110.561 GF SST 4 Leg
Building Height Tower Height Vertical Space On Tower Tower Extension Required
72m YES x NO
CLIENT Client Site ID Client Site Name Client Contact Contact Phone #
Smartfren ZSMG_0039/ZTE_1004 HUB-Karang Tengah
1. BTS ANTENNAS (RF)
Item
ANTENNA DETAILS CABLES
Height (m) Quant Manufacturer Model Quant Size (")
1.1 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 85 2 7/8
1.2 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 190 2 7/8
1.3 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 285 2 7/8
1.4 E 41 1 MOBI MB800-90-17DE10 1980x296x156 65 2 7/8
1.5 E 41 1 MOBI MB800-90-17DE10 1980x296x156 215 2 7/8
1.6 E 41 1 MOBI MB800-90-17DE10 1980x296x156 310 2 7/8
1.7 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 80 4 1/2
1.8 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 170 4 1/2
1.9 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 260 4 1/2
Remarks:
2 . MW ANTENNAS (Transmission)
Item
ANTENNA DETAILS CABLES
Height (m) Quant Manufacturer Model Diameter (m) Quant Size (")
2.1 E 39 1 ZTE WTG 0.6 265
2.2 E 36 1 ZTE WTG 1.8 60
2.3 R 38 ZTE MW 1.2 47
2.4 N 38 1 ZTE WTG 1.8 47
2.5 E 47 ZTE WTG 3.0 67
2.6 E 32 ZTE WTG 0.6 85 130498
2.7 E 61 ZTE WTG 2.4 85
2.8 E 34 ZTE WTG 0.6 205
2.9 R 46 ZTE MW 3.0 240
2.10 N 48 ZTE WTG 3.0 240
2.11 E 42 ZTE WTG 1.2 225
2.12
Remarks: Link FE to dir 130498
3 . OTHER(RRU/FILTER/GPS)
Item
AMPLIFIER DETAILS CABLES
Height (m) Quant Manufacturer Model Quant Size (")
3.1 E 11 1 GPS
3.2 N 11 1 GPS
3.3 N 36.5 3 R8862A - FDD 422x218x133
3.4 N 36.5 3 External Filter 210x 180x 107
3.5
Remarks:
4. SHELTER/POWER REQUIREMENTS
TYPE OF EQUIPMENT REQUIRED : x INDOOR (SHELTER) OUTDOOR (CABINET) OTHER (See Remarks)
EQUIPMENT PAD DIMENSIONS : Length : Width :
ELECTRICITY REQUIREMENTS : kVA : n x A (phases) :
PERMANENT GENSET REQUIRED : YES NO
GENSET DIMENSIONS : Length : Width:
Remarks: New WCDMA Flexi Multi Radio
Account Manager Quality Control Colocation Client
This application is valid for 15 calendar days.
e - existn - newr -remove
Dimensions (mm)(LxWxD) Azim (0)
e - existn - newr -remove
Azim (0)
e - existn - newr -remove
Dimensions (mm)(LxWxD) Azim (0)
![Page 2: ZSMG_0039 HUB-Karang Tengah](https://reader036.vdocument.in/reader036/viewer/2022082709/55cf9297550346f57b97ced3/html5/thumbnails/2.jpg)
Colocation ApplicationToday's Date 19-Apr-2023
Colo Application Date 19-Apr-2023
Revision 0
IBS Site ID Island Province CitySMG_01N020 Java Central Java Semarang
Latitude (Decimal/DMS) Longitude (Decimal/DMS) Site Type Tower Type
Date Date Date Date
* The requested Coax Cable size is greater than the specification allowed in the MLA. Lessee must install the cables using a feeder cable clamp to reduce the wind loading effect on the tower.
Client acknowledges certain sites require permanent genset (no PLN available) and will be responsible for providing its own permanent power.