Colocation Application Today's Date 27-Aug-2022 Colo Application Date 27-Aug-2022 Revision 0 IBS Site ID Island Province City SMG_01N020 Java Central Java Semarang Latitude (Decimal/DMS) Longitude (Decimal/DMS) Site Type Tower Type -6.9261 110.561 GF SST 4 Leg Building Height Tower Height Vertical Space On Tower Tower Extension Required 72m YES x NO CLIENT Client Site ID Client Site Name Client Contact Contact Phone # Smartfren ZSMG_0039/ZTE_1004 HUB-Karang Tengah 1. BTS ANTENNAS (RF) Item ANTENNA DETAILS CABLES Height (m) Quant Manufacturer Model Quant Size (") 1.1 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 85 2 7/8 1.2 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 190 2 7/8 1.3 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 285 2 7/8 1.4 E 41 1 MOBI MB800-90-17DE10 1980x296x156 65 2 7/8 1.5 E 41 1 MOBI MB800-90-17DE10 1980x296x156 215 2 7/8 1.6 E 41 1 MOBI MB800-90-17DE10 1980x296x156 310 2 7/8 1.7 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 80 4 1/2 1.8 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 170 4 1/2 1.9 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 260 4 1/2 Remarks: 2 . MW ANTENNAS (Transmission) Item ANTENNA DETAILS CABLES Height (m) Quant Manufacturer Model Diameter (m) Quant Size (") 2.1 E 39 1 ZTE WTG 0.6 265 2.2 E 36 1 ZTE WTG 1.8 60 2.3 R 38 ZTE MW 1.2 47 2.4 N 38 1 ZTE WTG 1.8 47 2.5 E 47 ZTE WTG 3.0 67 2.6 E 32 ZTE WTG 0.6 85 130498 2.7 E 61 ZTE WTG 2.4 85 2.8 E 34 ZTE WTG 0.6 205 2.9 R 46 ZTE MW 3.0 240 2.10 N 48 ZTE WTG 3.0 240 2.11 E 42 ZTE WTG 1.2 225 2.12 Remarks: Link FE to dir 130498 3 . OTHER(RRU/FILTER/GPS) Item AMPLIFIER DETAILS CABLES Height (m) Quant Manufacturer Model Quant Size (") 3.1 E 11 1 GPS 3.2 N 11 1 GPS 3.3 N 36.5 3 R8862A - FDD 422x218x133 3.4 N 36.5 3 External Filter 210x 180x 107 3.5 Remarks: 4. SHELTER/POWER REQUIREMENTS TYPE OF EQUIPMENT REQUIRED : x INDOOR (SHELTER) OUTDOOR (CABINET) OTHER (See Remarks) EQUIPMENT PAD DIMENSIONS : Length : Width : ELECTRICITY REQUIREMENTS : kVA : n x A (phases) : PERMANENT GENSET REQUIRED : YES NO GENSET DIMENSIONS : Length : Width: Remarks: New WCDMA Flexi Multi Radio Account Manager Quality Control Colocation Client This application is valid for 15 calendar days. e - exist n - new r -remove Dimensions (mm) (LxWxD) Azim ( 0 ) e - exist n - new r -remove Azim ( 0 ) e - exist n - new r -remove Dimensions (mm) (LxWxD) Azim ( 0 )

Upload: jily-rain

Post on 25-Dec-2015

220 views

Category:

Documents


1 download

DESCRIPTION

iiii

TRANSCRIPT

Page 1: ZSMG_0039 HUB-Karang Tengah

Colocation ApplicationToday's Date 19-Apr-2023

Colo Application Date 19-Apr-2023

Revision 0

IBS Site ID Island Province CitySMG_01N020 Java Central Java Semarang

Latitude (Decimal/DMS) Longitude (Decimal/DMS) Site Type Tower Type-6.9261 110.561 GF SST 4 Leg

Building Height Tower Height Vertical Space On Tower Tower Extension Required

72m YES x NO

CLIENT Client Site ID Client Site Name Client Contact Contact Phone #

Smartfren ZSMG_0039/ZTE_1004 HUB-Karang Tengah

1. BTS ANTENNAS (RF)

Item

ANTENNA DETAILS CABLES

Height (m) Quant Manufacturer Model Quant Size (")

1.1 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 85 2 7/8

1.2 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 190 2 7/8

1.3 E 36.5 1 MOBI MB800-90-17DE10 1980x296x156 285 2 7/8

1.4 E 41 1 MOBI MB800-90-17DE10 1980x296x156 65 2 7/8

1.5 E 41 1 MOBI MB800-90-17DE10 1980x296x156 215 2 7/8

1.6 E 41 1 MOBI MB800-90-17DE10 1980x296x156 310 2 7/8

1.7 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 80 4 1/2

1.8 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 170 4 1/2

1.9 N 36.5 ZTE LDXX-6515DS-VTM 2027 x 549x 165 260 4 1/2

Remarks:

2 . MW ANTENNAS (Transmission)

Item

ANTENNA DETAILS CABLES

Height (m) Quant Manufacturer Model Diameter (m) Quant Size (")

2.1 E 39 1 ZTE WTG 0.6 265

2.2 E 36 1 ZTE WTG 1.8 60

2.3 R 38 ZTE MW 1.2 47

2.4 N 38 1 ZTE WTG 1.8 47

2.5 E 47 ZTE WTG 3.0 67

2.6 E 32 ZTE WTG 0.6 85 130498

2.7 E 61 ZTE WTG 2.4 85

2.8 E 34 ZTE WTG 0.6 205

2.9 R 46 ZTE MW 3.0 240

2.10 N 48 ZTE WTG 3.0 240

2.11 E 42 ZTE WTG 1.2 225

2.12

Remarks: Link FE to dir 130498

3 . OTHER(RRU/FILTER/GPS)

Item

AMPLIFIER DETAILS CABLES

Height (m) Quant Manufacturer Model Quant Size (")

3.1 E 11 1 GPS

3.2 N 11 1 GPS

3.3 N 36.5 3 R8862A - FDD 422x218x133

3.4 N 36.5 3 External Filter 210x 180x 107

3.5

Remarks:

4. SHELTER/POWER REQUIREMENTS

TYPE OF EQUIPMENT REQUIRED : x INDOOR (SHELTER) OUTDOOR (CABINET) OTHER (See Remarks)

EQUIPMENT PAD DIMENSIONS : Length : Width :

ELECTRICITY REQUIREMENTS : kVA : n x A (phases) :

PERMANENT GENSET REQUIRED : YES NO

GENSET DIMENSIONS : Length : Width:

Remarks: New WCDMA Flexi Multi Radio

Account Manager Quality Control Colocation Client

This application is valid for 15 calendar days.

e - existn - newr -remove

Dimensions (mm)(LxWxD) Azim (0)

e - existn - newr -remove

Azim (0)

e - existn - newr -remove

Dimensions (mm)(LxWxD) Azim (0)

Page 2: ZSMG_0039 HUB-Karang Tengah

Colocation ApplicationToday's Date 19-Apr-2023

Colo Application Date 19-Apr-2023

Revision 0

IBS Site ID Island Province CitySMG_01N020 Java Central Java Semarang

Latitude (Decimal/DMS) Longitude (Decimal/DMS) Site Type Tower Type

Date Date Date Date

* The requested Coax Cable size is greater than the specification allowed in the MLA. Lessee must install the cables using a feeder cable clamp to reduce the wind loading effect on the tower.

Client acknowledges certain sites require permanent genset (no PLN available) and will be responsible for providing its own permanent power.