2007 hotel resort

2
Hotel / Resorts Campton Place Hotel San Francisco, California Designed electrical power, lighting and 300 KV A emer gency generator sy stems for 12-s tory high-rise hotel. Generator design included coordinati on of load to go on genera tor, si zi ng of  generator an d emergency tr ansfer switch. Generator design also included design of control diagrams and routing of exhaust to the out sid e of the bui ldi ng. Witn ess test ing and cert ifi cat ion of emergency equipment was provided. Donatello Hotel San Francisco, California 15-s to ry building wi th 2 le ve ls of subterranean parking. Investigated the integrity of the HVAC, plumbing, fire protection, electrica l power, li ghting, and sec urity systems. NBA studied the design drawings which were not representative of as-built systems (no as -built were available), maintenance reports, testing contractor reports, and fire marshal inspection report and provided an inve stig ative re port of our findi ngs with several alternatives and cost estimates for repairs, upgrades, and / or replacement of unacceptable systems. Roosevelt Hotel Hollywood, California A 12-story building. Provided new HVAC, plumbing, Fire Protection, Electrical power and lighting design for this hotel with an outdoor caf é and re staurant. Named in honor of President The odore Roosevelt, the Hollywood Roosevelt had its grand opening on May 15, 1927. It was built at a cost of $2.5 million The Hollywood Roosevelt is listed on the National Registry of Historic Places. Snake Creek Florida Keys, Florida Includes wet-slip spaces and dry-stack storage units, ships stor e, barbecue area, office spa ce, a state of the ar t fish-cleanin g sta tio n, plus other amenities. NBA provided elec tri cal load calculations for 20 power stations/pedes tal, site lighting, pump out station and fuel station and other design and engineering services. 897 Hyde Street 2nd Floor San Francisco, California 94109  Telephone (415) 202 9840 Facsimile (415) 202 9838 www.nbaeng.com

Upload: tom-lease

Post on 31-May-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2007 Hotel Resort

8/15/2019 2007 Hotel Resort

http://slidepdf.com/reader/full/2007-hotel-resort 1/2

Hotel / Resorts

Campton Place Hotel San Francisco, CaliforniaDesigned electrical power, lighting and 300 KVA emergencygenerator systems for 12-story high-rise hotel. Generator designincluded coordination of load to go on generator, sizing of generator and emergency transfer switch. Generator design alsoincluded design of control diagrams and routing of exhaust to theoutside of the building. Witness testing and certification of emergency equipment was provided.

Donatello Hotel San Francisco, California15-story building with 2 levels of subterranean parking.Investigated the integrity of the HVAC, plumbing, fire protection,electrical power, lighting, and security systems. NBA studied thedesign drawings which were not representative of as-built systems(no as-built were available), maintenance reports, testingcontractor reports, and fire marshal inspection report and providedan investigative report of our findings with several alternativesand cost estimates for repairs, upgrades, and / or replacement of unacceptable systems.

Roosevelt Hotel Hollywood, CaliforniaA 12-story building. Provided new HVAC, plumbing, Fire Protection,Electrical power and lighting design for this hotel with an outdoorcafé and restaurant. Named in honor of President TheodoreRoosevelt, the Hollywood Roosevelt had its grand opening on May15, 1927. It was built at a cost of $2.5 million The HollywoodRoosevelt is listed on the National Registry of Historic Places.

Snake Creek Florida Keys, FloridaIncludes wet-slip spaces and dry-stack storage units, ships store,barbecue area, office space, a state of the art fish-cleaning

station, plus other amenities. NBA provided electrical loadcalculations for 20 power stations/pedestal, site lighting, pump outstation and fuel station and other design and engineering services.

897 Hyde Street 2nd Floor San Francisco, California 94109 Telephone (415) 202 9840 Facsimile (415) 202 9838

www.nbaeng.com

Page 2: 2007 Hotel Resort

8/15/2019 2007 Hotel Resort

http://slidepdf.com/reader/full/2007-hotel-resort 2/2

Hotel / Resorts

St. Regis Museum Tower San Francisco, California43-story hotel, condominium and cultural center development. Thenew 484 foot tall structure will have 19 floors of condominiums, 16floors of five-star hotel, five floors of hotel public space, and fourfloors of underground parking. NBA designed the HVAC, plumbing,and reviewed electrical power, lighting, emergency power, and firealarm system and telephone and communications system.

Watermark Marina of Wilmington North CarolinaLocated near three waterways – the Cape Fear River, theIntracoastal Waterway and the Atlantic Ocean. Marina features

floating dock, full-service amenities, new clubhouse with lounge, abarbecue and picnic area, and dry-stack boat storage. NBAprovided complete MEP design services to the boat area and theclub house building. Provided electrical, lighting and fire alarmsystems for the boat storage area and club house building.

897 Hyde Street 2nd Floor San Francisco, California 94109 Telephone (415) 202 9840 Facsimile (415) 202 9838

www.nbaeng.com