CLIC SERIES

INSTALLATION

MANUAL

Page 2: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

2

Table of Contents General Description……………………………………………………………………………………...3

Advantages of the Clima-Flex units……………………………………..……………………4

Installation Diagrams…..………………………………………………...………………….....6

Nomenclature……………………………………………………………………………………………..7

Electrical Diagram……………………………………………….…………………………………….....8

Technical Sheet…………………………………………………..………………………………………10

Dimensions………………………………………………………………………………………………..11

Installation and unit startup……….………………….………………………………………………….12

Installation…………………………………….………………………………………………....13

Pre-startup Checklist………………………………………….………………………………..14

Energy / Power supply inspection….....……………………………….……………………...15

Control panel inspection………………………………………………………………………..16

Initial Startup…………………………………………………………………………….……....16

Compressors…………………………………………………………………………………….………..17

Maintenance……………………………………………………………………………………………....19

Hydraulic Maintenance…..……………………………………………………………………...19

Electrical Maintenance..………………………………………………………………….……..19

Physical Inspection……………………………………………………………………………...19

Hydraulic Connection………………………………………………………………….…………..……...21

Nipple Connection………………………………………………………….……..……………..21

Head Connection…………………………………………………………….…………………..23

Hydraulic Connection Diagram……………………………………………………..…………………...25

Page 3: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

3

1. GENERAL DESCRIPTION

GENERAL DESCRIPTION

Clima-Flex chilled water generator units are controlled by

technically specialized software, scroll type compressors,

evaporators, hydronic components (optional) and various

safety protections. The units operate with refrigerant R-410A.

EQUIPMENT

Factory assembled. All piping, wiring and controls needed for

operation are integrated inside the units

MODULE

Hot dipped galvanized base aluminum frame, Pintro sheet

panels insulated with anticorrosive film, panels for easy

access for maintenance without compromising the stability of

the unit.

COMPRESORES

Hermetic scroll compressors, modulating and variable speed

(inverter).

CONDENSERS

High efficiency condenser made of Microchannel tube.

Condensers can be ordered with anticorrosive coating.

Water-cooled units use plate type heat exchangers.

EVAPORATORS

The evaporators are compact and use plate heat

exchangers. Both coolant and hydraulic connections are

properly insulated.

FANS

Centrifugal long distance discharge fans or axial low noise

operation.

COMPONENTS

Refrigeration Controls

The units have solenoid valves, expansion valves, dehydrate

filters and service valves.

ELECTRICAL COMPONENTS

All units come with a control panel, which contains all the

safety and protection devices against external and internal

overheating, compressor protection controls, flow and power

failure detection, and freezing protection. The control panel

includes indicator LED lights.

HYDRONIC COMPONENTS (OPTIONAL)

Water circulation pump

The water pump is fully enclosed and has an anti-corrosion

casing.

Water expansion tank

Installed to absorb the thermal expansion of water has a 2-

gallon capacity.

CONTROL

All Clima-Flex units can be connected to the internet. This

allows for remote control and operation of the units, as well

as remote diagnostics and follow-up maintenance (graphs,

trends, cycle times, alarms, diagnostics, etc.), installation is

simple and flexible using on site internet access.

Page 4: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

4

1.1. CLIMA-FLEX UNITS ADVANTAGES

Clima-Flex CLIC units leave the factory as a kit ready to be installed outdoors at both the floor or ceiling level. The use of air-cooled condensers eliminates the cost and the need to install and maintain a cooling tower.

The CLIC family has a smaller footprint and lower weight than the competition. Installation of the cold water pipes is also easier. All CLIC units leave the factory with the water quick connect connections installed and ready to be used. Grooved or threaded water connections are also available for easy installation. Optionally the units may require a pumping module; this module reduces installation time and space dedicated to a pump room.

All Clima-Flex CLIC units have been tested on the factory to ensure proper operation.

Clima-Flex CLIC units are designed to require less service calls. The scroll compressors can last hundreds of thousands of hours of continuous operation in different applications and conditions. The Adsil special anticorrosive coating ensures longer life and better performance.

The components and control sequences used in our units are designed to keep CLIC Clima-Flex units always running, safety and health monitoring systems optimize performance on the go.

The units are designed to meet the AHRI Standard 55/590 and the UL-1995 standard security.

Page 5: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

5

EFFICIENCY

CLIMA-FLEX water chillers are designed to comply with all requirements on all commercial projects. Air cooled CLIC CLIMA-FLEX units may be applied in many ways; the units can be installed as stand alone or in any number combination to get the exact required capacity for the project demands. The operation allows modulating in accordance with the building thermal load variations, and achieving the desired temperature in a precise and fast manner with high efficiency and minimum energy consumption. CLIC CLIMA-FLEX unit capacity ranges from 25 to 275 Tons of cooling. OPERATION

CLIV CLIMA-FLEX units have reduced vibration levels making them virtually silent. The overall design allows for easy, fast, and low price installation.

QUALITY

Each unit is carefully manufactured and individually tested under strict international standards. CLIC CLIMA-FLEX units have state of the art components that offer a high quality product.

ENVIRONMENTALLY FRIENDLY

CLIMA-FLEX units use R-410A refrigerant to reduce operating costs, and contribute to a significant reduction of CO2 emissions. We are ecofriendly and strive to make green quality products.

Page 6: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

6

1.2. INSTALLATION DIAGRAM

Page 7: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

7

2. NOMENCLATURE

Page 8: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

8

3. ELECTRICAL DIAGRAMS

Page 9: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

9

Page 10: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

10

4. DIMENSIONES

Page 11: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

11

Page 12: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

12

5. INSTALLATION AND UNIT STARTUP

/!\ WARNING /!\ LOCATION

To keep warranty this unit must be

installed by trained personnel with

expertise on water chillers installation.

Some of the voltages on the unit may

be dangerous, before servicing it is

recommended to totally de-energize

the unit.

CLIC Units are designed to be installed outdoors.

It is necessary that the unit has air venting, and a

free air intake (see Fig 1) to allow for good air

circulation and allow access for maintenance.

For fully functioning, CLIC units only require the

connection with the hydraulic local net and power

supply connection in accordance with technical

data sheet.

Note: For optimal operation if the CLIC unit is

installed in a machinery room, it should be at a

maximum temperature of 95 °F (35 °C)

Page 13: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

13

5.1. INSTALATION

The following items must be checked before the unit´s startup.

DATE:

JOB SITE:

LOCATION:

CONTRACTOR:

TECHNICIAN / COMPANY THAT PERFORMS STARTUP:

UNIT MODEL:

UNIT SERIAL:

The following procedures are to be considered by the installer; personnel must be qualified and certified to perform installation in order to comply all specifications and good practices to assure the

correct unit´s operation.

1.- PHYSICAL INSPECTION (BEFORE ELECTRICAL CONECTION)

● Check unit for possible transportation or handling damage.

● Visual check for refrigerant leaks.

● Only Open unit to install system piping. Do not remove connection´s protection until hydraulic circuit is to be closed.

● Check for foreign objects in fan discharge.

● Check pulley alignment and band tension.

● Check that air intake is not obstructed, and has the required space suggested on Fig. 1

2.- HYDRAULIC CIRCUIT INSPECTION

Water connections are NPT type inner thread (to identify the connection diameter, see unit’s data sheet). Installation of a water filter is necessary on all hydraulic circuits in order to avoid solid particles in it, which must be installed on the return side of the circuit, and cleaned once the system´s initial charge is finished.

● Check water filter to be clean.

● Verify that all service valves are open.

● Check for adequate makeup water supply.

● Verify that all piping is filled with water and air has been vented out.

● Check Thermometers.

● Check Manometers.

Note: Accessories such as Thermometers, manometers, measuring ports, etc. are recommended

but not necessary for the unit´s operation.

/!\ WARNING /!\ If hydraulic circuit contains air, it may compromise the units operation.

Page 14: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

14

5.1.1. ELECTRICAL SUPPLY INSPECTION

The electrical piping is nipple NPT threaded conduit (1” inch diameter on all models) the units

require 3 phase grounded electrical power.

● Verify that the thermo-magnetic switch is of correct capacity for the unit.

● Check that all electrical connections are tight.

● Check for false contacts on ground, and all wiring.

● Check internal connections for control and power.

● Measure voltage on all lines, and ground, neutral, and TF line.

● Check for overload protection on motors to be in position to design requirements,

and on automatic mode.

● Check voltage monitor control (*Motor Saver), to be adjusted to supply the correct

power voltage for the unit.

Note: The unit´s control panel has a ventilation duct, and it must not be obstructed in any manner.

*The unbalance percentage of electrical supply

should be calculated with the following formula and

adjusted on the UNBALANCE TRIP knob.

UNBALANCE PORCENTAGE = [(MAXIM

AVERAGE DEVIATION)/(AVERAGE)]X[100]

Note: CLIMA-FLEX units are previously factory

adjusted however the electrical supply may vary on

each installation, and due to this unbalance must be

adjusted before startup in order to protect all the

unit´s motors and electrical components.

DIAGNOSIS INDICATING LIGHTS

(LED STATUS)

NORMAL

OPERATION

CONSTANT GREEN

START DELAY INTEMITENT GREEN

INVERTED

PHASE

INTERMITENT RED

PHASE

UNBALANCED

RED ON LAPSES

HIGH / LOW

VOLTAGE

CONSTANT RED

Page 15: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

15

5.1.2. CONTROL PANEL INSPECTION

● Check the control panel to ensure that it is free of foreign objects.

● Energize the unit with 3 phase electrical power. Phase unbalance must less than

2% of average.

● Cycle each fan to assure rotation is correct

● Cycle water pump (if applicable) to ensure that it is correctly energized.

¡CAUTION!

CLIC* units are equipped with scroll compressors which must rotate freely or mayor damage to the

compressor may happen. Check rotation previously.

5.2. STARTUP

After finishing the inspection of the previous installation points and making sure all the unit’s items

are correct the unit may be started.

1. UNIT CONTROL

Set the UNIT CONTROL switch on the ON position (Fig 2) to energize the control panel with 24

Volts.

After energizing the controller, wait five minutes for the unit to be on line and ready.

2. ON/OFF

Operation sequence will initiate by checking all security pre-programed points on the unit. If all

required conditions are OK the unit will be ready to initiate operation.

To start operation set the ON/OFF switch (Fig 2) to the ON position.

After six seconds the controller will command the start of the water pump.

If water flow is detected on the pipes, the internal sequence of the unit will begin.

Page 16: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

16

6. COMPRESSORS

Set the APG1 switch, 24V (Fig. 2) to the ON position afterwards set the APG2 switch also to the

ON position, finally set the APG3 (Reset) switch to ON, this will enable the compressors start

cycle.

Note: The APG4 switch (Fig. 3) selects the unit´s operating mode, whether is it cooling only or

heat pump. If you wish to operate the unit as heat pump turn this switch to ON.

Fig.2 Cooling Only Mode

frío o bomba de calor. Si desea que funcione en modo bomba de calor active el apagador.

Fig. 3 Heat-Pump Mode

Compressor 24V Reset

Page 17: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

17

CLIC SERIES

MAINTENANCE

MANUAL

Page 18: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

18

1. MAINTENANCE

1.1 HYDRAULIC MAINTENANCE

Monthly Trimonthly Semester Yearly

Hydraulic filters cleaning (if present)

Visual Inspection of all pipes for leak detection.

Replenish Water on hydraulic circuit.

Verify that there is no air on the water pipes

Verify the air purge valve (must be clean and in

working order)

1.2 ELECTRICAL MAINTENANCE

Monthly Trimonthly Semester Yearly

Check all electrical connections, power, and control

panels.

Physical inspection of all relays, and starters on the

electrical panel.

Check amperage on all motors, and compare them

to plate values.

Physically check for false contacts.

Verify status of all electrical protections to be under

the manufacturer specifications.

Clean the electrical panels.

Very that the power line connectors are clean and

tight at the main power switch and at the

compressor.

1.3 PHYSICAL INSPECTION

Monthly Trimonthly Semester Yearly

Condenser cleaning with pressurized clean water,

interval depends on ambient conditions.

Check refrigerant load (3 months period).

Change fan motor bearings as necessary.

Verify electrical power consumption on compressors,

to determine refrigerant leaks.

Page 19: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

19

CLIC SERIES

CONNECTION MANUAL

Page 20: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

20

1. HYDRAULIC CONNECTION

1.1 NIPPLE CONNECTION

Align the units flush side by side to begin the installation.

Install the O-rings on the

connections rods.

The connection rods have to be installed inside the unit, when

properly aligned the O-rings will seal the nipple connections.

Page 21: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

21

Ranura para el

Indentation for the O-ring

Make sure that the O-rings are evenly distributed along both ends

of the pipe.

Install the couplings covering the O-rings.

Note: The couplings should make a

perfect fit around the O-rings.

Tightly close and adjust the couplings using nuts and bolts (½

inch).

Page 22: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

22

1.2 CONNECTION ROD INSTALLATION

Install the O-rings on the

connections rods.

Install the connection rods on the

cold water distribution system.

Make sure that the O-rings make a

perfect water proof seal.

Install the couplings covering the O-rings.

Note: The couplings should make a

perfect fit around the O-rings.

Tightly close and adjust the couplings using nuts and bolts (½

inch).

Page 23: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

23

Note: Vitaulic ends have to be installed on the cold water in and out ports on the side that will not be in use.

Page 24: CLIC SERIES INSTALLATION MANUAL - Clima-Flex

REV. 2015-SEP-13 Clima-Flex S.A. de C.V.

24

1.3 HYDRAULIC CONNECTION DIAGRAM