clima canal hybrid clima canal - master group

12
1 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com. 27 January 2017 CLIMA CANAL HYBRID LOW TEMPERATURE SYSTEM / HEATING AND COOLING CLIMA CANAL LOW TEMPERATURE SYSTEM / HEATING Low Water Temperature system CLIMA CANAL HYBRID: Build-in height of 3.94” > 5.71” CLIMA CANAL: Build-in height of 3.35” > 5.43” fan speed modulation via 0-10V signal

Upload: others

Post on 19-Jan-2022

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

1CLIMA CANAL ECJaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com. 27 January 2017

CLIMA CANAL HYBRIDLOW TEMPERATURE SYSTEM / HEATING AND COOLING

CLIMA CANALLOW TEMPERATURE SYSTEM / HEATING

Low Water Temperature system

• CLIMA CANAL HYBRID: Build-in height of 3.94” > 5.71”

• CLIMA CANAL: Build-in height of 3.35” > 5.43”

• fan speed modulation via 0-10V signal

Page 2: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

2 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Clima Canal Hybrid / Clima Canal parts / height adjustment

8 Dynamic Heat Exchanger

9 Tangential EC mini fan

10 Connection for ventilation system (OPTION)

11 Electrical connection always on the left hand side

12 Hydraulic connection always left

13 Condensate drain Ø 0.78” (HYBRID)

1 Protection panel

2 Alu or wooden grille

3 Connection cover

4 1/2” NPT connections

5 Micro height adjustment

6 End cap

7 Macro height adjustment

Parts

1

2

3

4

5

6

7

8

9

10

11

12

13

Height adjustment (inch)

max 0.8

< Height adjustment

Fine height adjustment (max 0.31”)Clima Canal Hybrid: min 3.94” > max 4.25”

Clima Canal: min 3.35” > max 3.66”

Height adjustment:max 1.77”

< Fine height adjustment

max

0.3

1”

Page 3: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

3CLIMA CANAL ECJaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Clima Canal Hybrid / Clima Canal dimensions / grille

General info

Benefits• height adjustment and fine height adjustment• ventilator(s): 24 VDC/ECM• fan speed control via 0-10V signal• sound pressure 29 dB(A), (med. speed = 80%),L108• aluminium grille• wooden grille• mounting / protection panel• can be installed as a continuous product, open spaces can be filled

with empty ducts

Option• height adjustible feet for raised floor• empty ducts for continuous installation• corner piece for continuous installationAccessories• JDPC.001 JAGA Dynamic Product Control• Power supply 24 VDC/VAC

*H: tolerance: 0 > 0.078”

Dimensions

Clima Canal -Heating only - Clima Canal HYBRID -Heating Cooling-

L (cm) L (inch) A (inch) ** H (cm) * H (inch) * H (cm) * H (inch)72.3 28.35 9.06

8.5 3.34 10 3.93108.3 42.52 8.66144.3 56.69 7.28

180.3 70.87 5.71

* Hybrid: condensate drain

Connection for ventilationsystem (OPTION)

*4.13 1.18

AL

7.082.36

H

1.06

7.873.541.18

Ø 1.18 ↓ ↓ Ø 0.78

Dimensions in inch

Grille

Aluminium grille Wooden grille

BNA Alu natureBCN Alu nature

* BNC/... Alu lacquered* BCC/... Alu lacquered

BON Oak BBN Beech

BOV Oak varnished BBV Beech varnished

0.47” 0.51”

0.24”BNA/BNC

BCN/BCC

0.35”

0.24” 0.24”

* To ensure perfect adherence of the lacquer coating, an extremely wear-resistant and UV-resistant polyester lacquer coating of the highest quality is used. Only in glossy (code 2..); or special color, code: 006 / 005 / 028 / 026

0.47” 0.51”

0.24”BNA/BNC

BCN/BCC

0.35”

0.24” 0.24”

0.47” 0.51”

0.24”BNA/BNC

BCN/BCC

0.35”

0.24” 0.24”

**H: tolerance: 0 > 0.078”

CODE: nomenclature

CLCM. 010 072 18 / ... / ...

Code

Hei

ght (

cm)

Leng

th (c

m)

wid

th (c

m)

Gri

ll

Gri

ll co

lour

*

* Only for grill BNC

Page 4: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

4 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Clima Canal Hybrid / Clima Canal dimensions

Heating capacity ** BTU/hr Cooling capacity (Hybrid only) ** BTU/hr

170/150/68°F 60/65/80 (DRY)Clima Canal 10 V 8 V 6 V 4 V 2 V Clima Canal 10 V 8 V 6 V 4 V 2 V

L072 3752 3107 2437 1731 964 L072 614 477 345 218 100

L108 7724 6397 5018 3563 1984 L108 1264 982 709 449 205

L144 12137 10053 7885 5599 3118 L144 1986 1543 1115 705 322

L180 16551 13709 10752 7635 4252 L180 2708 2104 1520 961 439

130/110/68°F 45/55/77°F 50% total *Clima Canal 10 V 8 V 6 V 4 V 2 V Clima Canal 10 V 8 V 6 V 4 V 2 V

L072 2120 1756 1377 978 545 L072 1322 1019 714 431 191

L108 4364 3614 2835 2013 1121 L108 2723 2098 1470 887 393

L144 6858 5680 4455 3163 1762 L144 4278 3297 2310 1393 618

L180 9351 7745 6075 4314 2402 L180 5834 4495 3150 1900 842

95/85/68°F 45/55/77°F sensible *Clima Canal 10 V 8 V 6 V 4 V 2 V Clima Canal 10 V 8 V 6 V 4 V 2 V

L072 899 745 584 415 231 L072 900 684 473 281 123

L108 1851 1533 1202 854 475 L108 1853 1408 973 579 253

L144 2908 2409 1889 1342 747 L144 2912 2213 1529 909 397

L180 3966 3285 2576 1829 1019 L180 3971 3017 2085 1240 542

Water flow heating max. Water flow cooling max.Clima Canal GPM Clima Canal GPM

L072 0,33 L072 0,21

L108 0,73 L108 0,42

L144 1,05 L144 0,63

L180 1,45 L180 0,85

• Supply heating water T°: 170°F / Return heating water T°: 150°F / Air inlet T°: 70°F• Supply cooling water T°: 60°F / Return cooling water T°: 65°F / Air inlet T°: 80°F dry bulb T°: - 50% RH (relative humidity)• * Supply cooling water T°: 45°F / Return cooling water T°: 55°F / Air inlet T°: 77°F dry bulb T°: - 50% RH (relative humidity) ** outputs for BNA / BNC grilles with 60% free area. Grilles with a free area of 50% have a deration factor of 0.8.• outputs are calculated for a BNA or BNC grill with a free area of 60% (0.35”) opening between the grill profiles. BCN or BCC grills with a free area

of 50%, have a deration factor of 0.8.• according to EN 16430

Page 5: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

5CLIMA CANAL ECJaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Clima Canal Hybrid / Clima Canal technical data

Jaga Clima Canal: Technical dataL 072 L 108 L 144 L 180

Heat Exchanger (coil)

Fins Per Inch (FPI)

Face Area ft2

Coil connections inch

10.6 fins per inch

0.035 ft2

1/2 NPT female

Fan

Quantity 1 1 2 2

Fan scroll diameter inch 1.77

Fan lenght inch 12.99 1x25.98 1x12.99, 1x25.98 2x25.98

Control JAGA Controller 1 room / JAGA Controller for multiple areas

EC Motor (24VDC)

Consumption W

2V

4V 0.9 1.4 2.4 2.9

6V

8V 1.7 2.9 4.8 6.2

10V 3.1 5.3 8.6 11.5

Quantity 1 1 2 2

RPM Speed med (7 VDC) 1950

RPM Speed max (10VDC) 2340

*Sound pressure dB(A)

2V 14 15 16 18

4V 15 19 20 22

6V 23 29 30 32

8V 28 32 35 37

10V 34 37 39 41

Voltage Volts 24VDC

Air Flow CFM

2V

4V 40 83 123 165

6V

8V 59 119 178 238

10V 70 142 213 284

Cabinet

Height, inch (HYBRID)* adjustable between: min 3.94 > max 5.71

Height inch adjustable between: min 3.35 > max 5.12

Length inch 28.35 42.52 56.69 70.87

Width inch 7.09

Fine adjustment height inch max 0.39

Weight lbs 14.11 22.27 31.75 41.45

Weight lbs (HYBRID)* 17.2 27.56 39.46 52.69

* with an assumed room attenuation of 8 dB(A) / content of the room 750 sqft / reverberation time 0.5 sec. / measured at 3.3ft height and 6.6ft from the appliance.

Page 6: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

6 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

OptionsHeight adjustable feet for raised floors

• painted in the colour black RAL 7024

• easy installation using stainless steel allen key bolts

• (1 set = 2 height adjustments)H

7.24” 3.15”CODE H (inch)

5209.05070000 1.97 > 2.765209.08170000 3.15 > 5.125209.13230000 5.12 > 9.06

5209.20300000 7.87 > 11.81

Number of feet per length:

L 72

L 108

L 144

L 180

L72 (28.35”) L144 (56.69”)

L108 (42.52”) L180 (70.87”)

Empty ducts (all Clima Canal Hybrid and Clima Canal (all standard lengths)

To fill open spaces for a continu-ous installation.

• without connection perforations

• with continuous grille

• with height adjustments and fine height adjustment

• with end caps

L 18

H

7.09

Clima CanalH L

008

072 cm (28.35”)

108 cm (42.52”)

144 cm (56.69”)

180 cm (70.87”)

CLCD.008 072 18 /... /...

Fill in Grill code

Fill in Grill colour code (BNC)

Clima Canal HybridH Canal L

010

072 cm (28.35”)

108 cm (42.52”)

144 cm (56.69”)

180 cm (70.87”)

CLCD.010 072 18 /... /...

Fill in Grill code

Fill in Grill colour code (BNC)

Corner piece

Connecting and finishing of corners.

• with grille

• height adjustment

Clima Canal Hybrid

CODE GrillCLCD.010 025 18/BNA Alu. natural

CLCD.010 025 18/BNC/... Alu. lacquered

Clima Canal

CODE GrillCLCD.008 025 18/BNA Alu. natural

CLCD.008 025 18/BNC/... Alu. lacquered

Fill in Colour code

Fill in Colour code

Connection piece for ventilation channel

3.54”1.57”

Size (3.54” x 1.57”)Add /VEN to Clima Canal code:Sample:CLCM.008 072 18 /... /VEN

7.93.5"

Clima Canal Hybrid / Clima Canal options

Page 7: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

7CLIMA CANAL EC

JAGA Dynamic Product Control , Jaga Control panel

On - Off controller, as a stand alone system

InstallationElectrical connections: IMPORTANT!

• the warranty is only valid when using the power supply provided byJaga

• the Jaga DPC is polarization-sensitive. By mixing the minus and plusconnection, the controller will be damaged. This damage is not cov-ered by Jaga warranty.

• the electrical connection of the unit must be carried out by qualifiedpersonnel, in compliance with the regulations applicable in the coun-try where the unit is installed

• non-conforming electrical connections releases Jaga from liabilityconcerning damage to objects and persons

Clima Canal Hybrid / Clima Canal Jaga control panel JDPC

Triggers fan at a set speed when hot water (above 86F) or chilled water (below 62F) flows through the Jaga coil

Wiring Diagram, fan control via JDPC

Wiring Diagram, fan control via 0-10V signal

Page 8: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

8 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Technical data CODE > 7990.050 7990.051 7990.052

Power Watt 36 60 100Output voltage VDC 24-28Output current A 1,3 2,5 4,2 Input voltage VAC 85-264 88-264

VDC 120-370 124-370Weight lbs 0.66 0.77Overload protection 120 - 145%LED DC okOperating tempe-rature

-40 > +185 ° F

AccessoriesPower supply 24VAC

• small mounting depth• safety: UL1310 Class 2• convection cooling• DIN-rail or wall mounting

CODE Description

7990.050 36 W

7990.051 60 W

7990.052 100 W

7.85.6

9.3

10

The warranty is only valid when using the original Jaga power supply.Required power = sum of the power consumption of the equipments

2.2

3.66

3.46 3.94

Clima Canal Cable length according to number of devices (feet) (max. voltage drop 5%)

Max. cable length in feet 32 65 98 131 164 197 230 262 295 328

Wire size ↓ Type 1 (4.37W), number of Clima Canals:

17 AWG 18 9 6 4 3 2 1

16 AWG 28 14 9 7 5 4 3 2 1

14 AWG 47 23 15 11 9 7 6 5

Wire size ↓ Type 2 (6.70W), number of Clima Canals:

17 AWG 12 6 4 3 2

16 AWG 18 9 6 4 3 2

14 AWG 30 15 10 7 6 5 4 3

Wire size ↓ Type 3 (10.30W), number of Clima Canals:

17 AWG 8 4 2 1

16 AWG 12 6 4 3 2

14 AWG 20 10 6 5 4 3 2

Wire size ↓ Type 4 (12.10W), number of Clima Canals:

17 AWG 6 3 2 1

16 AWG 10 5 3 2 1

14 AWG 17 8 5 4 3 2

Clima Canal Hybrid / Clima Canal accessories

Page 9: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

9CLIMA CANAL ECJaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

In cooling mode: the pipes must have sufficient thermal insulation to prevent condensation

Sufficient space for curtains foreseen!

20 cm

7.87”

Cleaning the duct• cleaning at regular interval is important, depending on the use and

function of the roomCleaning the grate• a dirty grate obstructs the flow of air to the ventilator. Clean the grate

at regular intervals, depending on the usage and function of the room. • the grate must not be dismantled for maintenance and can simply be

cleaned with a vacuum cleaner.

Attention !!

What is sound power, sound pressure

Sound power is noise production of the device itself (sound source). The sound power is thus considered as a fixed value independent of the installation situation.

Sound pressure is the perceptible sound. This depends on the in-stallation situation and on several factors:• the location of the device• the environmental condition• the distance to the measured sound source• the reflection of the sound (depending on the size and the height

of the room and the materials used)Note: The sound power is always higher than the perceived sound pressure.

Reverberation time: Reverberation time is the time - in seconds - which is neces-sary to lower the sound pressure level of 60 dB after the sound source is switched off. This shows that the reverberation time in a large room will be larger than in a small room. Particularly the acoustics and decoration of the room determines the reverbera-tion time.

Sound power sound pressure

Page 10: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

10 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Dimensions hydraulic connection (INCH)

0...10V

24VD

C

CLIM

A C

AN

AL

1

3

2

1.06"

4.13"2.55"

1.57"A

Ø 1.18"

Clima Canal Hybrid / Clima Canal_pressure drop

L 180L 144

L 108L 072

15

20

30

40

60

80

100

200

300

400

600

800

100

0

0.06

60.

088

0.1

3 0

.18

0.2

6 0

.35

0.4

4

0.8

8

1.3

2 1

.76

2.6

4 3

.52

4.4

1008060504030

20

1086543

2

10.80.60.50.40.3

0.2

0.1

3.34

26.76 33.45

0.260.33

0.66

1.001.331.672.002.67

20.0316.7213.3810.03

6.69

0.200.160.130.10

0.06

0.03

∆P[Kpa]

∆P[Ft/Hd]

0.40

4.02

8.04

12.116.120.124.132.1

80.40

121161201241321402

0.80

1.211.612.012.413.21

40.2

∆P[inch H2O]

LPH

GPM

Water flow in LPH / GPM

Work pressure: 145.038 PSI

Pres

sure

dro

p in

Ft/

Hd,

Kpa

, inc

h H

2O

Clima Canal Hybrid / Clima Canal technical data

Ovall Canal Length (inch) A (inch)

28.35 9.06

42.52 8.66

56.69 7.28

70.87 5.71

Page 11: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

11CLIMA CANAL ECJaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Product description• inner duct with height adjustment and SS grille supports.• anodized aluminium grille(s)• dynamic heat exchanger.• fans (tangential mini fan).Clima Canal Hybrid - heating and cooling:• pre-assembled heating unit for building into the floor, comprising

of a 0.04” thick duct of Sendzimir galvanized steel plate and a telescopically adjustable height adjustment with stainless steel grilleholder, coated with a charcoal grey scratch-proof epoxypolyesterlacquer, RAL 7024, 10% gloss.

• the appliance is equipped as standard for heating and for connection to traditional water heating systems, but can also be used for coolingwith a chilled water supply and for connection to mechanical ventila-tion systems.

• a minimum recess depth of 3.94” below finished floor level is required. The appliance is equipped with a height adjustment from 0 to 1.77” and a fine height adjustment up to + 0.315” to perfectly align the appliancewith the finished floor.

• there are 4 connection openings in the outer duct for the passage of the hydraulic pipes and electric cables. These openings - in the side – aresealed with black insulation tape.

• the shaft is also equipped with a condensate drain ø 1.26”/0.08”• two head ends are supplied, equipped with a stainless steel grille sup-

port and aluminium rivets with countersunk heads for finishing theends of the inner duct.

• all components are secured with special spring steel suspensionhooks, so all the parts can be removed easily for regular cleaningand maintenance without hydraulic or electrical disconnection.

Clima Canal - heating only:• pre-assembled heating unit for building into the floor, comprising

a 0.04” thick duct of Sendzimir galvanized steel plate and a telescopically adjustable height adjustment with stainless steel grilleholder, coated with a charcoal grey scratch-proof epoxypolyesterlacquer, RAL 7024, 10% gloss.

• the appliance is equipped as standard for heating and for connectionto traditional water heating systems, and for connection to mechanical ventilation systems.

• possible to achieve a minimum recess depth of 3.35”. The appliance is equipped with a height adjustment from 0 to 1.77” and a fine heightadjustment up to + 0.315” to perfectly align the appliance with the finished floor.

• there are 3 connection openings in the outer duct for the passage of the hydraulic pipes and electric cables. These openings - in the side – aresealed with black insulation tape.

• two end caps are supplied, equipped with a stainless steel grille sup-port and aluminium rivets with countersunk heads for finishing theends of the inner duct.

• all components are secured with special spring steel suspensionhooks, so all the parts can be removed extremely quickly and easilyfor regular cleaning and maintenance without hydraulic or electricaldisconnection.

General:Aluminium grille:Aluminium floor grille bars L 14.17” with EPDM holder 0.65”.• profile: 0.24” x 0.55”.• spacing 0.25”.• material: AluminiumRoll-up wooden grille:Wooden profiles positioned crossways.• profile: 0.47” x 0.59”.• spacing 0.51”.The wooden profiles are connected by way of a galvanised spring. The correct interspace is assured by aluminium spacers.Versions: oak / beech / oak varnished / beech varnished

Dynamic heat exchanger:Round, seamless circular pipes in pure copper, connected to pure alu-minium panels with a spacing of 0.07” and an integrated brass collector, including air venting.• the heat exchanger electrostaticaly lacquered with black epoxy-polyes-

ter, gloss degree 70%.• element pressure test: 290 psi.• operating pressure: max 145 psi.• 1/2” NPT standard connection left.FansOne or more near noiseless tangential fans, 24 VDC, with Sendzimir galvanized steel plate cover and integrated stainless steel grate. Colour black, glossiness 70%.Electric connectionIntegrated electric connection box with manual tension spring system.Standard connection left.How to install:The installer will propose all the heating elements, while taking into account the following requirements:• a heat loss calculation according to the standard guidelines for the re-

gion• heat emission and measurement tables in compliance with the tables

and Clima Canal fitting instructions supplied by the manufacturer• the heating elements are connected to a two-pipe system / single-sid-

ed connection. Standard connections left• install the Clima Canal with the convector side towards the exterior

side of the room• the distance between the Clima Canal and the window should allow

for any curtain. Curtains should never be hung above the Clima Canal.The heating element should be accessible at all times for maintenance.

• if the appliance is not mounted directly on the floor, the space between the bottomside of the appliance and the floor must be filled with a sta-ble filling, e.g. wet cement.

Manufacturer: JagaType: Clima Canal Hybrid

Clima Canal

Clima Canal Hybrid / Clima Canal product description

Page 12: CLIMA CANAL HYBRID CLIMA CANAL - Master Group

12 CLIMA CANAL EC Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. jaga-usa.com / jaga-canada.com.

Jaga Canada Climate Systems Inc.375 University Ave. E.Suite 205AWaterloo, Ontario N2K 3M7Canada

[email protected]@jaga-canada.comwww.jaga-usa.comwww.jaga-canada.com

Rim insulation:

If a screed is to be applied (poured floor or a cementitious screed) rim insulation will be required on the long side of the appliance; to protect it and to cope with expansion differences during heating or cooling.

Acoustic isolation

Insulation against airborne noiseSound is reflected by hard materials. Soft, porous substances are best suited to absorbing airborne sound. Contact sound insulationSound travels very easily in hard materials. Contact sound insulation will largely depend on this: A. Quality of the placementContact pointsMake sure that sound- and/or mechanical vibrations cannot be transfer-red between different elements, e.g. between the built-in heaters and a metal carrier, through pipes, along air ducts etc. Hollow acoustic spaces.Where air can travel, so can sound:Isolate the built-in heaters in hollow acoustic spaces. Avoid cavities be-tween insulation and pipes. These form small resonance boxes. Avoid cavities along air ducts (the acoustic effect cannot be predicted for this).