esa/estec tec-qcs overview of a space qualification process - radiation characterization and beyond...
TRANSCRIPT
ESA/ESTECTEC-QCS
Overview of a Space Qualification Process -
Radiation characterization and beyond
L. BONORA, ESA/ESTEC-Component Division
Xanthi - Oct 2006
ESA/ESTECTEC-QCS
SUMMARY
Radiation: effects on EEE components Radiation: tests & requirements Beyond radiation, overview of the relevant
requirements for space components/flight models.
ESCC Evaluation/Qualification ApproachMinimum Quality Management Requirements
ESA/ESTECTEC-QCS
Radiation: effects on EEE components (1)
Total Ionizing Dose (TID)Degradation of μelectronics and optoelectronicsCumulative long term effectsParameter drifts, threshold shifts, timing changes, functional failures
Non Ionizing Effects – Displacements DamageDegradation of optoelectronics (GaAs …), CCDs, bipolar technologies in very harsh environmentsCumulative long term effects ( disruptions of crystal lattice)CMOS technologies less affected ( majority carriers)
ESA/ESTECTEC-QCS
Radiation: effects on EEE components (2)
Single Event Effects (SEE)Single charged particles (heavy Ions and protons) passing through a semiconductor materialSoft errors: data corruption (SEU), system shutdown (SEFI), transients (SET)…Hard errors ( sometimes destructive): Latch-up ( SEL), Stuck bits (SHE), Gate ruptures ( Power MOSFETs and thin capacitors in analog devices)…
New effect types or unknown manifestations of known effects always possible especially for new technologies
ESA/ESTECTEC-QCS
Radiation: Tests and requirements for TID
Usual particle type: γ rays (1.17 & 1.33 MeV) from Co60 sourcesEffects similar to/ representative of space radiationHigh penetration (parts irradiated “as is” on test boards)
European Specification: ESCC 22900Experimental Set-up
Sample size: (10 + 1) parts in gal, from a single lotStatic bias ( considered as a worst case) ON and OFFTotal dose ~100 krad(Si) max. in several steps (0/5/10/20/50/100)Dose rate < 360 rad(Si)/h
Actual space dose rate very low ( a few rad(Si)/h) High dose rate not relevant for bipolar/ BiCMOS technologies due to ELDRS
Facilities: one source at ESTEC, several in Europe (e.g., ONERA Toulouse)
ESA/ESTECTEC-QCS
Radiation: Tests and requirements for SEE (1)
General:Characterization: experimental curve σ vs. LET (HI) or energy (p+)
σ = ratio number of events / number of incident particlesKey parameters: σ sat, LETth and Weibull fit For LETth < 12 MeV.cm2/mg → proton sensitivity possibleBased on these parameters → event rate calculations
For SET, pulse energies are also important pulse amplitudes and durations have to be determined
For some events (e.g., SEGR), destruction of the test samples can’t be preventedResults may be strongly dependent from test patterns or application conditions
European Specification: ESCC 25100
LET
satcm2
LETth
LET (MeVcm2mg-1 )
ESA/ESTECTEC-QCS
Radiation: Tests and requirements for SEE (2)
Experimental method:Fluences > 106 HI/cm2 or > 1010 p+/cm2
Sample size: ( 3+1) min.Particle range > 30 μmBias: dynamic or staticThe range of LETs (HI)/Energies (p+) must be sufficient to determine threshold and saturation A min. of 5 LET/Energy steps is requiredDe-lidded parts for HI – Back side irrad. possible
Experimental Set-upESA supported facilities: HIF(B), PSI (CH), RADEF (F)Other facilities in Europe (IPN- Orsay) or in the USA (BNL …)
ESA/ESTECTEC-QCS
Radiation: Tests for Displacement Damage
Experimental method: Unit of interest: NIEL ( Non Ionizing Energy Loss)
Affected types: CCDs / Optocouplers / GaAs (and similar material) based components …
Ground test: protons ( pref. < 60 MeV), fluences > 1010 p+/cm2
neutrons ( ~ 1MeV), fluences > 1010 n/cm2
Some parts are also TID sensitive ( if a silicon chip is included)
Sensitivity to bias conditions
ESA/ESTECTEC-QCS
Radiation: points of contact at ESTEC & facilities availability
Who to contact ? Radiation Effects Section (TEC-QCA)TID, DD: Ali Mohammadzadeh - [email protected]
SEE: Reno Harboe - Sorensen - [email protected]
Availability of the facilities can be checked on line in ESA radiation section of ESCIES
https//escies.org
ESA/ESTECTEC-QCS
Radiation characterization of a component/technology is a mandatory step BUT
A lot more is required to get a Flight Model
At this stage, one has to distinguish between:– An approval on a case by case basis which is an
individual and limited authorisation for a specific project
– A full ESCC Qualification ( including an Evaluation phase in the ESCC system) which is a general and long term authorisation of use in space
Let’s first briefly present the relevant requirements
ESA/ESTECTEC-QCS
RELEVANT REQUIREMENTS
• ECSS European Coop. for Space Standardisation
– Space Project Management; Space Product Assurance; Space Engineering
ECSS-Q60A: Requirements for supply and use of EEE components at equipment level
• ESCC European Space Components Coordination ( ESCC is the preferred option)
– The ESCC System is an international system for the specification / qualification / procurement of EEE components for use in Space programmes. It covers:
• the technical specification of EEE parts• methodologies for component evaluation and qualification• testing methods / quality assurance / operational provisions
ESA/ESTECTEC-QCS
RELEVANT REQUIREMENTS
ECSS- Q60A
Non-qualified components have to be evaluated ECSS defines what to do but not how to do The evaluation programme shall include:
A constructional analysis A manufacturer assessment An Evaluation testing
Electrical stress ( Life test, HTRB …) Mechanical stress ( shocks, vibrations …) Environmental stress ( temp. shock and cycling, seal tests …) Assembly capability Radiation testing ( TID and SEE)
ESA/ESTECTEC-QCS
ESCC Eval. / Qualif. Approach: The ESCC system in brief
For users, 3 levels of specifications:• Basic: test methods, qualification methodology and general requirements applicable
to all ESCC components
• Generic: requirements for screening, periodic or lot acceptance testing and qualification testing for individual families of components
• Detail: performance requirements for individual or ranges of particular components
ESCC 20000 – Using the ESCC Specification System
An international system for the specification / qualification / procurement of EEE components
for use in Space programmes
ESA/ESTECTEC-QCS
ESCC QUALIFICATION
• ESCC qualification approval is a status given to electronic components which are manufactured under controlled conditions and which have been shown to meet all the requirements of the relevant ESCC specifications.
• Unlike the US MIL System, ESCC is based on a 2 step qualification approach: Evaluation + Qualification
• During the Evaluation phase, components/technologies can be more extensively characterised and margins determined
• 3 main phases:– Manufacturer Evaluation ( ESCC 20200) -> AUDIT– Component Evaluation ( ESCC 22600 and ancillaries)
• Preparation and realization of an agreed Evaluation Test Program ( ETP) including:– Constructional analysis and technology evaluation – Step-Stress testing
• Preparation of a Process Identification Document (PID) & Detail Specification– Component Qualification testing
• On components produced strictly as defined in the final PID and from a given lot• According to ESCC Generic Spec. requirements
ESA/ESTECTEC-QCS
COMPONENT EVALUATION
• Constructional Analysis– On random samples taken from the current production – Performed by the Evaluation Authority (ESCC Executive)
• Evaluation Test Programme – Established in conjunction Manufacturer / ESCC Executive– On a sample ( ~ 100 parts) representative of the component family – In order to determine failure modes and margins, it includes:
• Endurance tests ( HTRB, Extended Burn-in, Life Test …)• Destructive tests ( Step-stress, radiation, Environmental/Mechanical/Assembly…)
– Includes a CA on representative components– Ancillary specifications 226xxxx* describe the procedure and requirements to
create and perform an ETP
ESCC QUALIFICATION ESCC 22600
Stand. Comp. Eval
*: xxxx = generic spec. number
ESA/ESTECTEC-QCS
COMPONENT EVALUATION
• Process Identification Document ( PID)
– Shall be prepared by the Manufacturer – Establishes a precise reference for an electronic component qualified in accordance with
the ESCC System • Component’s design configuration• Materials used in manufacture • Manufacturing processes and controls • Inspections and tests to be carried-out during and after manufacture
– PID shall be in accordance with the requirements of ESCC 22700
• Detail Specification – Necessary if not already described by an existing Detail Specification – Or if the existing specification requires updating
– Described in ESCC 20800.
ESCC QUALIFICATION ESCC 22600
Stand. Comp. Eval
ESA/ESTECTEC-QCS
QUALIFICATION TESTING PHASE
• Prerequisites:– Successful completion of the Evaluation Phase (EPPL listing)
– The PID reviewed and approved by ESCC Executive
– A production and test schedule for major processing operations
– A Production Flow Chart, Process Schedules and Inspection Procedures
ESCC QUALIFICATION
• Components required for qualification testing must be produced strictly in accordance with the PID • Qualification testing of the component must be in accordance with the requirements of the relevant
ESCC Generic Specification • On successful completion of the testing phase => ESCC QPL• A Qualification, once established, is valid for 2 years
ESA/ESTECTEC-QCS
ESCC Gen. Spec. 9000
Integrated Circuits, Monolithic, hermetically Sealed
CHART F1
ESCC 9000describes the general requirements for-Qualification-Qualification maintenance-Procurement-Deliveryof hermetically sealed, hermetic ICs.
F2
F3
F4-SG2 (ESCC Qual)- optionalF4 (Not ESCC Qual)- mandatory
F4
GENERAL FLOW FOR PROCUREMENT (ESCC GS 9000)
DELIVERY
PERIODIC TESTING
Special In-Process Controls
PRODUCTION CONTROL
RELEASE
LOT VALIDATION TESTING
SCREENING TESTS
Wafer Lot Acceptance
ESA/ESTECTEC-QCS
(previous SCC Chart II and III)
all lots for qualification, maintenance, lot validation and delivery
shall be submitted to inspections and tests
24h, max. store temp. rating
devices with cavities
(PDV) values recorded agaisnt SN
(HTRB) duration and conditions in ESCC DS
values recorded agaisnt SN, drifts calculated lot failure criteria
240h, alternative allowed (detailed in 1015)
values recorded agaisnt SN, drifts calculated lot failure criteria
3 θ values recorded agaisnt SN lot failure criteria
3 θ values recorded agaisnt SN lot failure criteria
sampling ( no failure allowed) lot failure criteria
Max failure rate: 5%
during 100% testing
ESCC DS
883-TM1014A/B/C
ESCC BS 20500
F4 if applicable
883-TM1008
883-TM1010C
883-TM2020A
883-TM1015A
883-TM1015 B/D/or E
ESCC DS
Check for LOT FAILURE
Seal (Fine and Gross Leak)
External Visual Inspection
Solderability
Power BI
Final PDV
High and Low Temp. Elec Measurements
Room Temp. Elec Measurements
PIND
Param. Drift Values (Initial Measurement )
High Temp., Reverse Bias, BI
PDV post HTRB and before Power BI
SCREENING TESTS / COMPONENTS FROM PRODUCTION CONTROL (F3)
All components shall be SERIALISED prior screening tests
High Temp. Stabilisation Bake
Temp. Cycling
ESCC 9000 – CHART F3
ESA/ESTECTEC-QCS
(previous SCC Chart IV and V)
SG1 SG2 SG3
Mecha. Shock Therm. Shock883-2002B 883-1011C
Vibration Moisture883-2007A 883-1004
Constant Acc.883-2001E
Seal Seal883-1014A/B/C 883-1014A/B/C
values recorded
agaisnt SN
Electrical Measurements
Electrical Measurements
Ext.Visual Insp. Ext.Visual Insp.ESCC 20500 ESCC 20500
QUALIFICATION AND PERIODIC TESTS (F4)
50 (1 type) /36 (per type if 2 types) /26 (per type if 3 types) Components
ENV./MECHA. Subgroup ENDURANCE SG ASSEMBLY SG
24 months period 12 months period 24 months period
15/11/8 components 15/11/8 components 5/3/2 components
883-1005
Electrical Measurements
883-2019
(values recorded agaisnt SN)
Seal883-1014A/B/C
Ext.Visual Insp.ESCC 20500
Permanence of MarkingESCC 24800
Terminal Strengh883-2004
Internal Visual InspectionESCC 20400
Bond Strengh883-2011
Die Shear
Operating Life Test 2000h
ESCC 9000 – CHART F4
ESA/ESTECTEC-QCS
QUALITY CONFORMANCE DOCUMENTATION AND REQUIREMENTS
• As a minimum, the Manufacturer quality management plan must address the ESCC 24600 requirements ( prescriptions to ISO 9001).
• The resulting Manufacturer quality management system has to include and demonstrate the application of all the applicable ESCC 24600 requirements.
QUALITY MANAGEMENT
As a minimum, the QM plan shall address the requirements of ESCC 24600
ESA/ESTECTEC-QCS
QUALITY CONFORMANCE DOCUMENTATION AND REQUIREMENTS
• An appointed CHIEF INSPECTOR with clearly defined authority and responsibility ( including CoC)
• CONTROL of NON-CONFORMING PRODUCTS invoking the requirements of ESCC 22800
• QUALITY and CONTROL DOCUMENTATION including:– Quality manual ( indicating as a objective the conformance to ESCC 24600)
– Document control procedures for all documents related to the ESCC components manufacture ( incl. subs./suppliers management)
– A maintained PID
– Change Control Programme establishing the requirement for documentation of ALL changes, their reasons and the associated data including reliability and re-qualification results
QUALITY MANAGEMENT
As a minimum, the QM plan shall address the requirements of ESCC 24600
ESA/ESTECTEC-QCS
QUALITY CONFORMANCE DOCUMENTATION AND REQUIREMENTS
• TRACEABILITY has to be maintained at all stages of production and tests for all lots – Quality records have to be maintained for 5 years ( possibly 10 in a near future)
– Record of all components found to be defective
• A Conversion of CUSTOMER REQUIREMENTS (specific tests or test vehicles, marking, rework, screening )
• A CONTROL/INSPECTION prog. Including:– On-receipt / incoming tests / inspections
– Applicable ESCC in-process monitoring/control and back-end tests
– Procedures shall detail the frequency, methods and criteria for evaluating test results
– Data shall be maintained
QUALITY MANAGEMENT
As a minimum, the QM plan shall address the requirements of ESCC 24600
ESA/ESTECTEC-QCS
QUALITY CONFORMANCE DOCUMENTATION AND REQUIREMENTS
• A training and certification programme with periodic recertification ( for operators involved in ESCC components manufacture)
• An appropriate failure analysis capability has to be established with documented procedures for the application of the techniques and the generation of reports. This capability may include the use of appropriate external facilities.
• A Calibration programme to meet ESCC 21500
QUALITY MANAGEMENT
As a minimum, the QM plan shall address the requirements of ESCC 24600