paco kp, kpv - grundfos express suitegrundfosexpresssuite.com/documentation/kpdatabooklet.pdf ·...

Download PACO KP, KPV - Grundfos Express Suitegrundfosexpresssuite.com/Documentation/KPDatabooklet.pdf · PACO KP, KPV 1. Features and ... TM05 5875 3912 TM05 7638 1313. Applications 2 PACO

If you can't read please download the document

Upload: hangoc

Post on 06-Feb-2018

253 views

Category:

Documents


8 download

TRANSCRIPT

  • GRUNDFOS DATA BOOKLET

    PACO KP, KPVSplit case pump60 Hz

  • Table of contents

    2

    PACO KP, KPV

    1. Features and benefits 3Nameplate 3

    2. Applications 4Commercial systems 4Industrial systems 4Water distribution 4Irrigation and aquaculture 4

    3. Product range 5Pump configurations 5

    4. Performance range 6KP 2-pole 6KP 4-pole 7KP 6-pole 8

    5. Construction 9KP pump, construction X2 9KP pump, construction X4 10KP pump, construction X5 and X7 11KP pump, construction XK and XV 12KP pump, typical end view - Horizontal 13Std. components and material specification 14Mechanical construction 15

    6. Operating conditions 18Ambient temperature and altitude 18Liquid temperatures and shaft seals 18Shaft seal 18Pressure 18Flow 19KP Impeller Max Sphere Size 19KP model number and construction code 20

    7. Curve charts and technical data 21How to read the curve charts 21Curve conditions 22Performance tests 22Witness test 22KP 2095-1/2 [2-pole] 23KP 3095-7/8 [2-pole] 24KP 4012-1/2 [2-pole] 25KP 4012-7/8 [2-pole] 26KP 2095-1/2 [4-pole] 27KP 2013-5/6 [4-pole] 28KP 3095-7/8 [4-pole] 29KP 3014-7/8 [4-pole] 30KP 4012-1/2 [4-pole] 31KP 4012-7/8 [4-pole] 32KP 4015-9/0 [4-pole] 33KP 5012-7/8 [4-pole] 34KP 5015-9/0 [4-pole] 35KP 6012-3/4 [4-pole] 36KP 6015-3/4 [4-pole] 37KP 6019-7/8 [4-pole] 38KP 6020-3/4 [4-pole] 39KP 8012-5/6 [4-pole] 40KP 8015-3/4 [4-pole] 41KP 8020-5/6 [4-pole] 42KP 1012-1/2 [4-pole] 43KP 1015-3/4 [4-pole] 44KP 1020-3/4 [4-pole] 45KP 1024-3/4 [4-pole] 46KP 1415-1/2 [4-pole] 47KP 6019-7/8 [6-pole] 48KP 6020-3/4 [6-pole] 49KP 8015-3/4 [6-pole] 50KP 8020-5/6 [6-pole] 51KP 1012-1/2 [6-pole] 52KP 1015-3/4 [6-pole] 53KP 1020-3/4 [6-pole] 54KP 1024-3/4 [6-pole] 55KP 1220-5/6 [6-pole] 56KP 1415-1/2 [6-pole] 57

    8. Bare shaft pump 58

  • Feat

    ures

    and

    ben

    efits

    PACO KP, KPV 1

    3

    1. Features and benefitsThe Paco KP horizontal split case pump and KPV vertical split case pump are single stage, centrifugal volute pumps with high energy efficiency and low life-cycle costs.

    Ease of service and long-term reliability are two of the selling features of the KP pumps. The split case design enables removal and dismantling of the internal pump parts (bearings, wear rings, impeller, and shaft seals) without disturbing the motor or pipe work. The two-bearing design means less vibration and higher reliability. The separate bearing housings allow for inspection of the seals, sleeves and bearings without removing the top half of the casing.

    The double-suction design reduces axial forces by directing flow into both sides of the impeller. The double-volute design, available on most models, reduces the radial load and minimizes noise and vibration. Shaft sleeves are used to protect the shaft from corrosion and wear, thus extending the overall life of the shaft and the pump.

    KP pumps cover this performance range:

    Flow rate: 60 to 12000 gpm [10 to 2700 m3/h] Head: 15 to 700 ft [5 to 215 m] Motor (P2): 10 to 2000 hp

    The pumps are non-self-priming, centrifugal volute pumps with radial suction and radial discharge ports and horizontal shaft. Impellers are hydraulically balanced.

    Paco KP pumps are available in these different options: Pump with motor and base (see fig. 1). Bare shaft pump, i.e. pump without motor, with base

    (see fig. 2). Bare shaft pump, i.e. pump without motor, without

    base (see fig. 3). Or any combination requested by the customer

    KPV pumps Same great features of KP, but in a vertical

    configuration for optimized space savings Optional lower sleeve bearing design for easier

    lower bearing maintenance.

    Fig. 1 KP pump with motor and base

    Fig. 2 KP bare shaft pump with base, coupling, and guard

    Fig. 3 KP bare shaft pump

    Nameplate

    TM04

    733

    1 19

    10TM

    05 5

    003

    2712

    TM05

    587

    5 39

    12TM

    05 7

    638

    1313

  • Applications

    PACO KP, KPV2

    4

    2. Applications

    The Paco KP pumps are used in these main fields of application: commercial systems industrial systems water distribution irrigation.

    Commercial systemsLiquid transfer and pressure boosting in: air conditioning, primary and secondary chilled

    water systems water condensing systems and cooling towers boiler feed and condensate systems district heating plants and heating systems swimming pools fountains.

    Industrial systemsLiquid transfer and pressure boosting in: process cooling and chilled water systems water condensing systems and cooling towers boiler feed and condensate systems industrial heating systems wash down and cleaning systems industrial processing systems (water, light

    chemicals, oils, etc).

    Water distributionLiquid transfer and pressure boosting in: public waterworks non-potable water systems.

    Irrigation and aquacultureIrrigation covers these applications: field irrigation (flooding) sprinkler irrigation drip-feed irrigation aqua farming.

    Fig. 4 KP pump used in commercial building applications

    Fig. 5 KP pump in sprinkler irrigation

    TM05

    597

    7 40

    12G

    R 2

    910

  • Prod

    uct r

    ange

    PACO KP, KPV 3

    5

    3. Product range

    Pump configurations

    To a great extent the pumps can be adapted to the requirements of the individual customer. For customized solutions, contact your local Grundfos company.

    Standard configuration Optional configuration

    Pump casing Cast Iron Ductile Iron

    Impeller Bronze Cast Iron Aluminium bronze Stainless steel

    Sleeve Bronze Stainless steel

    Coupling Elastomeric Grid Spacer Coupling

    Shaft seal Mechanical seal: Soft packing

    Flange ANSI 125 ANSI 250

    Flushing line None Nylon Copper Stainless Steel

    Wear rings Bronze Stainless Steel

    Shaft Steel Stainless Steel

    Motor efficiency class NEMA Premium Others on request

    Pump direction of rotation CW - clockwise CCW - counter clockwise

  • Performance range

    PACO KP, KPV4

    6

    4. Performance rangePaco KP pumps are available with 2-, 4- or 6-pole motors. 8 and 10 pole are available on request.The next three pages show the performance range covered by these three motor types.Knowing your required duty point, use the performance ranges like this:

    1. Go into the relevant performance range chart.2. Find your duty point.3. Note which pump type covers your duty point.4. Go to section "Product range" and then to

    "Performance curves and technical data" and find more detailed information on your chosen pump.

    KP 2-pole

    TM05

    504

    5 38

    12100

    150

    200

    250

    300

    400

    500

    600

    800

    1000

    1500

    2000

    Q [U

    S G

    PM

    ]

    80100

    120

    150

    200

    300

    400

    500

    [ft]H

    2330

    4050

    6070

    8090

    100

    100

    200

    300

    Q [m

    /h]

    2530405060708090100

    100

    [m]

    HK

    P35

    50 rp

    m, 6

    0 H

    z

    4012

    -7/8

    4012

    -1/2

    3095

    -7/8

    2095

    -1/2

  • Perf

    orm

    ance

    ran

    ge

    PACO KP, KPV 4

    KP 4-pole

    TM05

    597

    8 38

    12

    100

    150

    200

    250

    300

    400

    500

    600

    800

    1000

    1500

    2000

    3000

    4000

    6000

    1000

    015

    000

    Q [U

    S G

    PM

    ]

    15202540506080100

    150

    200

    250

    400

    500

    600

    800

    [ft]H

    2330

    4050

    6070

    8010

    010

    020

    030

    040

    050

    060

    080

    010

    0010

    0020

    00Q

    [m/h

    ]

    101020304050607080100

    100

    200

    [m]

    HK

    P17

    80 rp

    m, 6

    0 H

    z

    4015

    -9/0

    1415

    -1/2

    1024

    -3/4

    1020

    -3/4

    1015

    -3/4

    1012

    -1/2

    8020

    -5/6

    8015

    -3/4

    8012

    -5/6

    6020

    -3/4

    6019

    -7/8

    6015

    -3/4

    6012

    -3/4

    5015

    -9/0

    5012

    -7/8

    4012

    -7/8

    4012

    -1/2

    3014

    -7/8

    3095

    -7/8

    2013

    -5/6

    2095

    -1/2

    7

  • Performance range

    PACO KP, KPV4

    8

    KP 6-pole

    TM05

    504

    7 38

    12

    400

    500

    600

    800

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    6000

    8000

    1000

    015

    000

    Q [U

    S G

    PM

    ]

    101215203040506080100

    120

    150

    200

    300

    400

    [ft]H

    100

    100

    200

    300

    400

    500

    600

    700

    800

    1000

    1000

    2000

    Q [m

    /h]

    45678101020304050607080100

    100

    [m]

    HK

    P11

    80 rp

    m, 6

    0 H

    z

    1415

    -1/2

    1220

    -5/6

    1024

    -3/4

    1020

    -3/4

    1015

    -3/4

    1012

    -1/2

    8020

    -5/6

    8015

    -3/4

    6020

    -3/4

    6019

    -7/8

  • Con

    stru

    ctio

    n

    PACO KP, KPV 5

    5. ConstructionPaco KP horizontal split case pumps are available in several different construction types.

    KP pump, construction X2All four construction types are available with packing as an option.

    Sectional view

    Fig. 6 Sectional view, construction X2, with mechanical shaft seals

    TM03

    995

    2 47

    07

    9

  • Construction

    PACO KP, KPV5

    10

    KP pump, construction X4Sectional view

    Fig. 7 Sectional view, construction X4, with mechanical shaft sealsTM

    05 7

    482

    1013

    113d

    195

    116b

    66 20e 45 11 17 49 6a 109 114 53 113e

    113c

    51

    11a

    105 24

    6b

    54

    116a

    124

    114a

    79

  • Con

    stru

    ctio

    n

    PACO KP, KPV 5

    KP pump, construction X5 and X7Sectional view

    Fig. 8 Sectional view, construction X5/X7, with mechanical shaft seals

    TM03

    995

    4 47

    07

    11

  • Construction

    PACO KP, KPV5

    12

    KP pump, construction XK and XVSectional view

    Fig. 9 Sectional view, construction XK/XV, with mechanical shaft seals

    TM03

    995

    5 47

    07

  • Con

    stru

    ctio

    n

    PACO KP, KPV 5

    KP pump, typical end view - Horizontal(Non-drive end)

    Fig. 10 Typical end view (non-drive end)

    TM04

    186

    4 11

    08

    13

  • Construction

    PACO KP, KPV5

    14

    Std. components and material specification

    Pos. no. Component Material ASTM standard

    6a Pump casing, upper Cast Iron ASTM A48 CL356b Pump casing, lower Cast iron ASTM A48 CL3511 Key, impeller Steel C1018, cold drawn steel

    11a Key, coupling Steel C1018, cold drawn steel17 Pipe plug Steel20 Drain plug R 1/2 Steel20a Plug, drain outlet Steel20b Plug, inlet Steel20c Plug, outlet Steel20d Plug, shaft seal flushing Steel20e Plug, suction chamber Steel24 Locking pin, wear ring Steel ANSI/ASME B18.8

    26b Roll pin Steel ANSI/ASME B18.826c Screw Steel45 Wear ring Bronze ASTM B148, C9520045b Wear ring with groove for retaining ring Bronze ASTM B148, C9520049 Impeller Silicon bronze ASTM B584, C8760051 Shaft Steel AISI 1144 Stress proof53 Ball bearing, drive end Steel54 Ball bearing, non-drive end Steel54c Washer Steel54d Retaining ring Carbon Spring Steel SAE 1060-109058 Seal cover Grey Iron

    58a Screw Steel65 Retaining ring Stainless steel, series 30366 O-ring NBR

    67aImpeller/shaft sleeve nut, right-hand thread Bronze lll932, C89835Impeller/shaft lock nut, right-hand thread Stainless steel

    67bImpeller/shaft sleeve nut, left-hand thread Bronze lll932, C89835Impeller/shaft lock nut, left-hand thread Stainless steel

    72a Gasket Vegetable fiber (HYD-401)76 Nameplate Aluminum79 Slinger Neoprene

    105 Shaft seal109 O-ring NBR

    109a O-ring NBR110 O-ring NBR113 Bearing housing Cast iron ASTM A48, CL30113c Bearing cover, drive end Cast iron ASTM A48, CL30113d Bearing cover, non-drive end Cast iron ASTM A48, CL30113e Gasket Vegetable fiber 113f Lip seal, non-drive end bearing NBR113g Lip seal, drive-end bearing NBR114 Screw Steel

    114a Screw Steel114b Screw Steel116 Shaft sleeve Bronze III932, C89835

    116a Shaft sleeve, drive end Bronze I836 C89833116b Shaft sleeve, non-drive end Bronze I836 C89833116c Shaft sleeve, inner Bronze I836 C89833116d Shaft sleeve, outer Bronze I836 C89833116e Set screw Steel124 Seal housing Cast iron ASTM A48 CL30195 Lubricating nipple Zinc coated steel

  • Con

    stru

    ctio

    n

    PACO KP, KPV 5

    Mechanical constructionPump casingThe class 35 grey iron volute pump casing has radial suction port and radial discharge port.The pumps are of the inline (symmetric) design.

    Fig. 11 Schematic drawing of an inline KP pump

    Flange Drillings are in accordance with ANSI #125 or #250.

    Fig. 12 Upper and lower pump casing of KP pump

    ShaftThe shaft (pos. 51) is of the key and keyway type with one key for the impeller (pos. 11) and one key for the coupling (pos. 11a).The shaft is supported by bearings at both the drive end and the non-drive end of the pump.

    Fig. 13 KP pump shaft

    Shaft sleeves are attached to the pump shaft to prevent wear of the shaft and secure the position of the impeller.

    BearingsKP pumps are fitted with two standard single-row deep-groove ball bearings. The bearings are of the open type permitting the bearings to be relubricated. The bearings are lubricated by Grundfos prior to delivery.

    Seal housingsAll KP pumps have two seal housings (pos. 124), one at the drive end and one at the non-drive end of the pump shaft. A seal housing has several functions: Supports the pump sealing system, whether it is a

    mechanical shaft seal or packing Supports the bearing housing thus transmitting both

    radial and axial forces from bearing and shaft to the upper and lower pump casing

    Has a connection for the flushing pipe.The function of the flushing pipe is to ensure a flow of pumped liquid for cooling and lubricating the mechanical shaft seal or the packing

    ImpellerThe KP impeller (pos. 49) is a closed double-suction impeller. The impeller has inflow of liquid from both sides and is locked in position by a threaded sleeve arrangement.

    Fig. 14 Double-suction impeller

    All impellers are dynamically balanced in accordance with ANSI/ISO 1940 Class G6.3 standard. Due to their design, the impellers are inherently hydraulically balanced and thus compensate for axial thrust.All impellers are trimmed to the duty point required by the customer.

    Wear ringsKP pumps have wear rings (pos. 45) between impeller and pump casing. As the name indicates, the wear rings protect the pump casing against wear. The wear rings act as a seal between impeller and pump casing.When the wear rings become worn, the efficiency of the pump will be reduced and the wear rings should be replaced.

    CouplingAs standard, KP pumps are fitted with a flexible grid coupling or elastomeric coupling, depending or motor size. The grid coupling consists of two steel flanges horizontally split coupling halves.

    TM04

    047

    6 07

    08TM

    04 0

    475

    0708

    TM04

    047

    7 07

    08

    TM03

    389

    1 11

    06

    15

  • Construction

    PACO KP, KPV5

    16

    The coupling design assists in reducing vibrations and cushions shock loads. The design also extends the life of the coupling itself. The flexible grid is standard for VFD driven pumps.

    Fig. 15 Flexible grid coupling

    The elastomeric coupling has a flexible rubber section to absorb vibrations and minimizes negative affects of misalignment.

    Fig. 16 elastomeric coupling

    Mechanical shaft sealThe material of the standard version is Buna Carbon/ceramic.

    Fig. 17 Rubber bellows shaft seal

    PackingIncludes graphite impregnated packing rings.

    The packing rings consist of braided material which is effective for long service life for packing rings while protecting the shaft sleeve.

    Fig. 18 Sectional view of packing with internal flushing liquid

    BasePump and motor are mounted on a common base frame designed according to Hydraulic Institute standard, ANSI/HI 1.3-2000.

    Painting Prior to delivery to the customer, pump, motor and base are top coated with a blue paint (RAL 5015); coating thickness is 2 to 4 mils.The inside of the pump is primered for corrosion resistance. Standard units are not painted internally.

    TM04

    047

    8 07

    08TM

    05 5

    784

    3812

    TM04

    047

    2 07

    08

    TM04

    184

    9 11

    08

    Pos. Description

    1 Shaft sleeve2 Gland3 Packing ring4 Lantern ringA Drilled hole for flushing liquid (pumped liquid)

  • Con

    stru

    ctio

    n

    PACO KP, KPV 5

    Test pressurePressure testing is made with water at ambient temperature. The standard hydrostatic test pressure is 1.5 times the flange rating pressure.

    KP Case working pressure limitations at 150 F: Flat-face flangesChart A

    All sizes except as Chart B indicates

    Chart B

    CWP: maximum Case Working Pressure based upon flange drilling. Maximum working pressure for a given application is determined by adding the maximum available suction pressure to the shut-off head of a given impeller diameter.

    Hydro: Is the hydrostatic test pressure applied to the pump. Minimum hydrostatic test pressure is 1.5 times maximum allowable case working pressure.

    Cass materialClass 125 lb flange drilling (psi) Class 250 lb flange drilling (psi)

    CWP Hydro CWP HydroCast iron 175 265 250 375Ductile iron 175 265 400 600

    Maximum case working pressure (class 125 Flange)

    Pump model number 6019 6020 8020 1020 1024 1220Cast iron

    175 psiDuctile iron

    Maximum case working pressure (class 250 Flange)

    Pump model number 6019 6020 8020 1020 1024 1220Cast iron 250 psi 250 psi 234 psi 222 psi 250 psi 211 psi

    Ductile iron 375 psi 375 psi 351 psi 333 psi 375 psi 317 psi

    17

  • Operating conditions

    PACO KP, KPV6

    18

    6. Operating conditions

    Ambient temperature and altitudeThe ambient temperature and the installation altitude are important factors for the motor life, as they affect the life of the bearings and the insulation system.Ambient temperature must not exceed 104 F [+ 40 C]. If the ambient temperature exceeds 104 F [+ 40 C] or if the motor is installed more than 3280 ft [1000 m] above sea level, the motor must not be fully loaded due to the low density and consequently low cooling effect of the air. In such cases, it may be necessary to use a motor with a higher output, or use a motor that is designed for the specified ambient conditions.

    Fig. 19 Relationship between motor output (P2) and ambient temperature

    Liquid temperatures and shaft sealsThe maximum liquid temperature marked on the pump nameplate depends on the mechanical shaft seal used:

    Temperature range for Buna - standard):32 F to 212 F [0 C to +100 C].

    Temperature range for Viton54 F to 212 F [+15 C to +100 C].

    Temperature range for EPDM54 F to 275 F [+15 C to +135 C].

    Shaft sealThe materials of the shaft seal types used in KP pumps have certain characteristics. These characteristics may be of importance when choosing the shaft seal for the pump.

    Carbon/CeramicThe seal has the following features: Brittle material requiring careful handling. Worn by liquids containing solid particles. Limited corrosion resistance, 5 < pH < 9, depending

    on ceramic type. The carbon of the seal offers properties very similar

    to the carbon/tungsten carbide seal. However, compared to the carbon/tungsten carbide seal, the pressure and temperature ranges are limited.

    Carbon/silicon carbide Seals with one carbon seal face have the following features: Brittle material requiring careful handling Worn by liquids containing solid particles Good corrosion resistance The self-lubricating properties of carbon make the

    seal suitable for use even with poor lubricating conditions (high temperatures) without generating noise. However, such conditions will cause wear of the carbon seal face leading to reduced seal life.

    BunaNBR (nitrile) rubber covers a wide range of liquids at temperatures below 212 F [+100 C]. Good mechanical properties Standard material

    VitonFKM rubber covers a very wide range of liquids and temperatures. Poor mechanical properties at low temperatures Resistant to water up to 275 F [+135 C] Resistant to mineral oils and vegetable oils Not resistant to alkaline liquids at high

    temperatures.

    EPDM EPDM Rubber covers a wider range of liquids up to a max temperature of 275 F [135 C].

    Good mechanical properties.

    PressureMaximum inlet pressureInlet pressure + pump pressure must always be lower than maximum pressure of the pump.

    Minimum inlet pressureThe minimum inlet pressure must correspond to the NPSH curve for the pump.

    TM00

    218

    9 15

    9820 25 30 35 40 45 50 55 60 65 70 T [C]5060708090

    100110[%]P2

    70 80 90 100 110 120 130 140 150 160 T [F]

    3280 7382 11483 15584 [ft]

  • Ope

    ratin

    g co

    nditi

    ons

    PACO KP, KPV 6

    FlowMinimum flow rateThe pump must not run against a closed discharge valve, as this will cause an increase in temperature/formation of steam in the pump. This may cause shaft damage, impeller erosion, short life of bearings, stuffing boxes with packing rings or mechanical seals due to stress or vibration.

    The minimum, continuous flow rate must be at least 25% of the flow rate at best-efficiency point (BEP).

    KP Impeller Max Sphere SizeSplit Case Model Max Sphere Size [inches]

    2095-1/2 0.192013-5/6 0.163095-7/8 0.313014-7/8 0.314012-1/2 0.384012-7/8 0.754015-9/0 0.255012-7/8 0.635015-9/0 0.756012-3/4 1.006015-3/4 0.816019-7/8 0.756020-3/4 0.758012-5/6 0.888015-3/4 1.008020-5/6 1.031012-1/2 1.001015-3/4 1.251020-3/4 1.201024-3/4 1.171220-5/6 1.871415-1/2 1.25

    19

  • PACO KP, KPV

    20

    KP model number and construction codeExample 29 60123 140001 1852Product codeModel codeMaterials of constructionMotor code

    Production code 2929: Split case

    Model code 60 12 3Pump discharge20 = 2"30 = 3"40 = 4"50 = 5"60 = 6"80 = 8"10 = 10"12 = 12"14 = 14"Nominal maximum impeller diameter95 = 9.5"12 = 12"13 = 13"14 = 14"15 = 15"19 = 19"20 = 20"24 = 24"Impeller designClockwise rotation:1, 3, 5, 7, 9Counter clockwise rotation:0, 2, 4, 6, 8

    Materials of construction 1 4 00 0 1Packing or seal3 = Standard Packing1 = Type 21, Single Seal, Ceramic Seat, Buna2 = Type 21, Single Seal, Tung Crbd Seat, Viton6 = Type 21, Single Seal, Ni-Resist Seat, Viton7 = Type 21, Single Seal, Ni-Resist Seat, Buna8 = Type 1B, Single Seal, Ni-Resist Seat, Buna9 = Type 21, Single Seal, Ni Resist Seat, VitonA = Type 1, Single Seal, Ceramic Seat, BunaB = Type 1, Single Seal, Ni-Resist Seat, VitonC = Type 1, Single Seal, Tung Cbrd Seat, VitonD = Type 1, Singel Seal, Ni Resist Seat, BunaE = Type 1, Single Seal, Ceramic Seat, BunaF = Type 1, Single Seal, Si Cbrd Seat, EPDMID of packing or seal2 = 1"3 = 1-1/4"E = 1-1/2"4 = 1-3/4"5 = 2-1/4"6 = 2-3/4"7 = 3"K = 3-1/2"V = 4"General configuration (horizontal)Code no Item00 Std.01 Dbl- wear rings02 Oil lube brgs03 (01) + (02)04 (01) + (05)05 Recirc lines20 Dbl Ext Shaft21 Dbl Wear Rings22 Recirc Lines

    24 (21) + (22)30 Dbl Ext Shaft31 Dbl Wear RingsGeneral configuration (horizontal)Code no Item32 Recirc Lines34 (31) + (32)70 250 lb. Flange71 Dbl Wear Rings72 (71) + (73)73 Recirc Lines90 250 lb. Flange91 Dbl Wear RingsGeneral configuration (Vertical)Code no Item50 Std51 Dbl. Wear Rings52 Sleeve Bearing80 250 lb. flamge81 Dbl. Wear Rings82 Sleeve Bearing92 250 lb. flamge93 Dbl. Wear RingsShaft/Sleeve Metallurgy0 = Steel/Bronze1 = Steel/S.S.3 = S.S.l/Bronze*6 = S.S./S.S. or S.S./no sleeves7 = SS/Hard. SSA = 316 SS/Ni Al BzX = SpecialPump Metallurgy1 = Brz. Fitted2 = Std. All Bronze5 = All Iron8 = Ductile Iron/Brz. FittedX = Special

    Motor code 1 78 2

    Enclosure1 = ODP2 = TECF3 = explosion proofVoltage

    HP1 phase 3 phase

    115/230 V 200 V 230/460 V1/31/23/41

    1-1/2

    2129354147

    2331374349

    2432384450

    235

    7-1/210

    5359657176

    5561677377

    5662687478

    1520253040

    ----------

    8184010203

    8285878889

    506075

    100125

    ----------

    04050607--

    9091929394

    150200250300

    --------

    --------

    95969798

    RPM1 = 35002 = 17503 = 1150

    Materials of construction 1 4 00 0 1

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    7. Curve charts and technical data

    How to read the curve chartsd

    Reference the Express Suite selection tool for selections in additional speeds.

    0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    360

    380

    400

    420[ft]H

    0

    20

    40

    60

    80

    100

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [m]H

    0

    10

    20

    30

    [m]

    KP 2095-1/260 Hz, n = 3550 rpm

    NPSH

    /6.75

    /7.5

    /8.125

    /8.75

    /9.5

    0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    [hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    [%]Eff

    0 20 40 60 80 100 120 140 Q [m/h]

    0

    20

    40

    60

    80

    100

    [kW]P2

    /6.75 /7.5 /8.125 /8.75 /9.5

    /6.75/7.5

    /8.125

    /8.75

    /9.5

    TM05

    500

    9 32

    12

    Pump type and speed

    Total pump head H = Htotal

    QH curve for the individual pump.The bold curve indicates the recommended performance range.

    The NPSH curve is an average curve for all variants shown.

    The power curves indicate pump input power [P2] for the pumps shown

    The eta curves show the efficiency of the pumps shown

    Size of impeller

    21

  • Curve charts and technical data

    PACO KP, KPV7

    22

    Curve conditionsThe guidelines below apply to the curves shown in the performance charts. Tolerances according to: Hydraulic Institute. The curves show pump performance with different

    impeller diameters at the nominal speed. The bold part of the curves show the

    recommended operating range. Do not operate the pump along the thin parts of the

    curves. If your duty point lies here, you should select a smaller or larger pump type.

    Do not use the pumps at minimum flows below 0.1 x Qmax stated on the pump name plate because of the risk of overheating of the pump.

    The curves apply to the pumping of airless water at a temperature of 77 F [+20 C] and a kinematic viscosity of 1 cSt [1 mm2/s].

    ETA: The lines show values of the hydraulic efficiency of the pump for the different impeller diameters.

    NPSH: The curves show average values measured under the same conditions as the performance curves.When sizing the pump, add a safety margin of at least 1.6 ft [0.5 m].

    In case of other densities than 62.3 lb/ft3 [1000 kg/m3] the discharge pressure is proportional to the density.

    When pumping liquids with a specific gravity higher than 1.0, motors with correspondingly higher outputs must be used.

    Calculation of total headThe total pump head consists of the height difference between the measuring points + the differential head + the dynamic head.

    Performance testsRequested tests are performed according to Hydraulic Institute. Performance tests are only completed when ordered with the pump.

    Witness testWhen the pumps are being tested it is possible for the customer to witness the testing procedure according to Hydraulic Institute.If the customer wants to witness the pump test this request must be submitted with the order.

    Hgeo : Height difference between measuring points.

    Hstat :Differential head between suction and the discharge side of the pump.

    Hdyn :Calculated values based on the velocity of the pumped liquid on the suction and the discharge side of the pump.

    Htotal Hgeo Hstat Hdyn+ +=

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 2095-1/2 [2-pole]

    0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    360

    380

    400

    420[ft]H

    0

    20

    40

    60

    80

    100

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [m]H

    0

    10

    20

    30

    [m]

    KP 2095-1/260 Hz, n = 3550 rpm

    NPSH

    /6.75

    /7.5

    /8.125

    /8.75

    /9.5

    0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    [hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    [%]Eff

    0 20 40 60 80 100 120 140 Q [m/h]

    0

    20

    40

    60

    80

    100

    [kW]P2

    /6.75 /7.5 /8.125 /8.75 /9.5

    /6.75/7.5

    /8.125

    /8.75

    /9.5

    TM05

    500

    9 32

    12

    23

  • Curve charts and technical data

    PACO KP, KPV7

    24

    KP 3095-7/8 [2-pole]

    TM05

    501

    0 32

    12

    0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    360

    380

    400

    420[ft]H

    0

    20

    40

    60

    80

    100

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [m]H

    0

    10

    20

    30

    [m]

    KP 3095-7/860 Hz, n = 3550 rpm

    /6.5

    /7.25

    /8

    /8.75

    /9.5

    NPSH

    0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 50 100 150 200 Q [m/h]

    0

    20

    40

    60

    80

    100

    [kW]P2

    /6.5

    /6.5

    /7.25

    /7.25

    /8

    /8

    /8.75

    /8.75

    /9.5/9.5

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 4012-1/2 [2-pole]

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    360

    380

    400

    420

    440[ft]H

    0

    20

    40

    60

    80

    100

    120

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    [m]H

    0

    10

    20

    30

    [m]

    KP 4012-1/260 Hz, n = 3550 rpm

    NPSH

    /6.5

    /7.5

    /8.4

    /9.4

    /10.3

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 50 100 150 200 250 300 Q [m/h]

    0

    40

    80

    120

    160

    200

    [kW]P2

    /6.5/7.5

    /8.4 /9.4 /10.3

    /6.5/7.5

    /8.4

    /9.4

    /10.3

    25

  • Curve charts and technical data

    PACO KP, KPV7

    26

    KP 4012-7/8 [2-pole]

    0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    360

    380

    400[ft]H

    0

    20

    40

    60

    80

    100

    120

    [ft]NPSH

    0

    10

    20

    30

    [m]

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [m]H

    KP 4012-7/860 Hz, n = 3550 rpm

    /7.0

    /7.6

    /8.2

    /8.8

    /9.4

    NPSH

    0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]0

    50

    100

    150

    200

    250

    300

    350

    400[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 100 200 300 400 Q [m/h]

    0

    50

    100

    150

    200

    250

    [kW]P2

    /7.0

    /7.0

    /7.6

    /7.6

    /8.2

    /8.2

    /8.8

    /8.8

    /9.4

    /9.4

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 2095-1/2 [4-pole]

    TM05

    501

    3 39

    12

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    [ft]H

    0

    10

    20

    30

    [ft]NPSH

    0

    2

    4

    6

    8

    [m]

    0

    5

    10

    15

    20

    25

    30

    35[m]H

    KP 2095-1/260 Hz, n = 1780 rpm

    NPSH

    /6.75

    /7.5

    /8.125

    /8.75

    /9.5

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 Q [US GPM]0

    2

    4

    6

    8

    10

    12

    14

    [hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    [%]Eff

    0

    2

    4

    6

    8

    10

    [kW]P2

    0 10 20 30 40 50 60 Q [m/h]

    /6.75 /7.5 /8.125 /8.75 /9.5

    /6.75/7.5

    /8.125

    /8.75

    /9.5

    27

  • Curve charts and technical data

    PACO KP, KPV7

    28

    KP 2013-5/6 [4-pole]

    TM05

    501

    4 39

    12

    0 40 80 120 160 200 240 280 320 360 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    [ft]H

    0

    10

    20

    30

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    [m]H

    0

    2

    4

    6

    8

    [m]

    KP 2013-5/660 Hz, n = 1780 rpm

    NPSH

    /9

    /10

    /11

    /12

    /13

    0 40 80 120 160 200 240 280 320 360 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    [hp]P2

    0

    10

    20

    30

    40

    50

    60

    [%]Eff

    0 20 40 60 80 Q [m/h]

    0

    10

    20

    30

    40

    [kW]P2

    /9/10

    /11/12

    /13

    /9/10

    /11/12

    /13

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 3095-7/8 [4-pole]

    TM05

    501

    5 39

    12

    0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    [ft]H

    0

    5

    10

    15

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35[m]H

    0

    1

    2

    3

    4

    [m]

    KP 3095-7/860 Hz, n = 1780 rpm

    NPSH

    /6.5

    /7.25

    /8

    /8.75

    /9.5

    0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]0

    4

    8

    12

    16

    20

    24

    28

    32[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0

    4

    8

    12

    16

    20

    [kW]P2

    0 20 40 60 80 100 120 Q [m/h]

    /6.5 /7.25/8 /8.75

    /9.5

    /6.5/7.25

    /8

    /8.75

    /9.5

    29

  • Curve charts and technical data

    PACO KP, KPV7

    30

    KP 3014-7/8 [4-pole]

    TM05

    501

    6 39

    12

    0 100 200 300 400 500 600 700 800 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70[m]H

    0

    5

    10

    15

    [m]

    KP 3014-7/860 Hz, n = 1780 rpm

    NPSH

    /10.0

    /11.0

    /12.0

    /13.0

    /14.0

    0 100 200 300 400 500 600 700 800 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    [hp]P2

    10

    20

    30

    40

    50

    60

    70

    [%]Eff

    0 50 100 150 200 Q [m/h]

    0

    10

    20

    30

    40

    [kW]P2

    /10.0 /11.0 /12.0 /13.0/14.0

    /10.0

    /11.0

    /12.0

    /13.0

    /14.0TM

    05 5

    016

    3212

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 4012-1/2 [4-pole]

    TM05

    501

    7 39

    12

    0 100 200 300 400 500 600 700 800 900 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    [ft]H

    0

    10

    20

    30

    40

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    40

    [m]H

    0

    2

    4

    6

    8

    10

    12

    [m]

    KP 4012-1/260 Hz, n = 1780 rpm

    NPSH

    /6.5

    /7.6

    /8.7

    /9.9

    /11.0

    0 100 200 300 400 500 600 700 800 900 Q [US GPM]0

    5

    10

    15

    20

    25

    30

    35

    40[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 50 100 150 200 Q [m/h]

    0

    5

    10

    15

    20

    25

    [kW]P2

    /6.5

    /7.6/8.7 /9.9

    /11.0

    /6.5

    /7.6

    /8.7

    /9.9

    /11.0

    TM05

    501

    7 32

    12

    31

  • Curve charts and technical data

    PACO KP, KPV7

    32

    KP 4012-7/8 [4-pole]

    TM05

    501

    8 39

    12

    0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    [ft]H

    0

    10

    20

    30

    40

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    [m]H

    0

    2

    4

    6

    8

    10

    12

    [m]

    KP 4012-7/860 Hz, n = 1780 rpm

    NPSH

    /7.0

    /8.3

    /9.5

    /10.8

    /12.0

    0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 50 100 150 200 250 Q [m/h]

    0

    10

    20

    30

    40

    50

    [kW]P2

    /7.0

    /7.0

    /8.3

    /8.3

    /9.5

    /9.5

    /10.8

    /10.8

    /12.0

    /12.0TM

    05 5

    018

    3212

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 4015-9/0 [4-pole]

    TM05

    501

    9 39

    12

    0 200 400 600 800 1000 1200 1400 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    [m]H

    0

    5

    10

    15

    [m]

    KP 4015-9/060 Hz, n = 1780 rpm

    NPSH

    /9.5

    /11.0

    /12.5

    /14.0

    /15.25

    0 200 400 600 800 1000 1200 1400 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 100 200 300 Q [m/h]

    0

    20

    40

    60

    80

    100

    [kW]P2

    /9.5

    /9.5

    /11.0

    /11.0

    /12.5

    /12.5

    /14.0

    /14.0

    /15.25

    /15.25TM

    05 5

    019

    3212

    33

  • Curve charts and technical data

    PACO KP, KPV7

    34

    KP 5012-7/8 [4-pole]

    TM05

    502

    0 39

    12

    0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    [ft]H

    0

    10

    20

    30

    40

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    [m]H

    0

    4

    8

    12

    [m]

    KP 5012-7/860 Hz, n = 1780 rpm

    /7.0

    /8.25

    /9.5

    /10.75

    /12.0

    NPSH

    0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90[kW]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 100 200 300 400 Q [m/h]

    /7.0

    /7.0

    /9.5

    /9.5

    /9.5

    /9.5

    /10.75

    /10.75

    /12.0

    /12.0

    TM05

    502

    0 32

    12

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 5015-9/0 [4-pole]

    TM05

    502

    1 39

    12

    0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    [m]H

    0

    5

    10

    15

    [m]

    KP 5015-9/060 Hz, n = 1780 rpm

    NPSH

    /9.0

    /10.5

    /12.0

    /13.5

    /15.0

    0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 100 200 300 400 500 Q [m/h]

    0

    40

    80

    120

    160

    200

    [kW]P2

    /9.0

    /9.0

    /10.5

    /10.5

    /12.0

    /12.0

    /13.5

    /13.5

    /15.0

    /15.0TM

    05 5

    021

    3212

    35

  • Curve charts and technical data

    PACO KP, KPV7

    36

    KP 6012-3/4 [4-pole]

    0 400 800 1200 1600 2000 2400 2800 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    [ft]H

    0

    10

    20

    30

    40

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    [m]H

    0

    2

    4

    6

    8

    10

    12

    [m]

    KP 6012-3/460 Hz, n = 1780 rpm

    NPSH

    /7.0

    /8.25

    /9.5

    /10.75

    /12.0

    0 400 800 1200 1600 2000 2400 2800 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    [hp]P2

    20

    30

    40

    50

    60

    70

    80

    90

    [%]Eff

    0 200 400 600 Q [m/h]

    0

    40

    80

    120

    160

    200

    [kW]P2

    /7.0

    /7.0

    /8.25

    /8.25

    /9.5

    /9.5

    /10.75

    /10.75

    /12.0

    /12.0

    TM05

    502

    3 32

    12

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 6015-3/4 [4-pole]

    TM05

    502

    4 39

    12

    0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    [m]H

    0

    5

    10

    15

    [m]

    KP 6015-3/460 Hz, n = 1780 rpm

    NPSH

    /9.0

    /10.5

    /12.0

    /13.5

    /15.0

    0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320[hp]P2

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 Q [m/h]

    0

    40

    80

    120

    160

    200

    [kW]P2

    /9.0

    /9.0

    /10.5

    /10.5

    /12.0

    /12.0

    /13.5

    /13.5

    /15.0

    /15.0

    37

  • Curve charts and technical data

    PACO KP, KPV7

    38

    KP 6019-7/8 [4-pole]

    0 400 800 1200 1600 2000 2400 2800 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320

    360

    400

    440

    [ft]H

    0

    20

    40

    60

    80

    [ft]NPSH

    0

    20

    40

    60

    80

    100

    120

    140[m]H

    0

    5

    10

    15

    20

    [m]

    KP 6019-7/860 Hz, n = 1780 rpm

    NPSH

    /15.0

    /16.0

    /17.0

    /18.0

    /19.0

    0 400 800 1200 1600 2000 2400 2800 Q [US GPM]0

    50

    100

    150

    200

    250

    300

    350

    400[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 200 400 600 Q [m/h]

    0

    50

    100

    150

    200

    250

    [kW]P2

    /15.0

    /15.0

    /16.0

    /16.0

    /17.0

    /17.0

    /18.0

    /18.0

    /19.0

    /19.0

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 6020-3/4 [4-pole]

    TM05

    502

    6 39

    12

    0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320

    360

    400

    440

    480

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    20

    40

    60

    80

    100

    120

    140

    [m]H

    0

    5

    10

    15

    [m]

    KP 6020-3/460 Hz, n = 1780 rpm

    /14.0

    /15.5

    /17.0

    /18.5

    /20.0

    NPSH

    0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]0

    100

    200

    300

    400

    500

    600

    700

    800[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 200 400 600 800 Q [m/h]

    0

    100

    200

    300

    400

    500

    [kW]P2

    /14.0

    /14.0

    /15.5

    /15.5

    /17.0

    /17.0

    /18.5

    /18.5

    /20.0

    /20.0

    TM05

    502

    6 32

    12

    39

  • Curve charts and technical data

    PACO KP, KPV7

    40

    KP 8012-5/6 [4-pole]

    TM05

    502

    7 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    [ft]H

    0

    10

    20

    30

    40

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    [m]H

    0

    2

    4

    6

    8

    10

    12

    [m]

    KP 8012-5/660 Hz, n = 1780 rpm

    /7.0

    /8.25

    /9.5

    /10.8

    /12.0

    NPSH

    0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    [hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000Q [m/h]

    0

    20

    40

    60

    80

    100

    120

    [kW]P2

    /7.0

    /7.0

    /8.25

    /8.25

    /9.5

    /9.5

    /10.8

    /10.8

    /12.0

    /12.0TM

    05 5

    027

    3212

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 8015-3/4 [4-pole]

    TM05

    502

    8 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    [m]H

    0

    5

    10

    15

    [m]

    KP 8015-3/460 Hz, n = 1780 rpm

    /9.0

    /10.5

    /12.0

    /13.5

    /15.0

    NPSH

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]0

    50

    100

    150

    200

    250

    300

    350

    400

    450[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 1200 Q [m/h]

    0

    50

    100

    150

    200

    250

    300

    [kW]P2

    /9.0

    /9.0

    /10.5

    /10.5

    /12.0

    /12.0

    /13.5

    /13.5

    /15.0

    /15.0

    TM05

    502

    8 32

    12

    41

  • Curve charts and technical data

    PACO KP, KPV7

    42

    KP 8020-5/6 [4-pole]

    TM05

    502

    9 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    360

    380

    400

    420

    440[ft]H

    0

    20

    40

    60

    80

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    [m]H

    0

    5

    10

    15

    20

    [m]

    KP 8020-5/660 Hz, n = 1780 rpm

    /14.0

    /15.31

    /16.62

    /17.94

    /19.25

    NPSH

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]0

    200

    400

    600

    800

    1000

    1200

    1400

    1600

    1800[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 1200 1400 1600 Q [m/h]

    0

    200

    400

    600

    800

    1000

    1200

    [kW]P2

    /14.0

    /14.0

    /15.31

    /15.31

    /16.62

    /16.62

    /17.94

    /17.94

    /19.25

    /19.25TM

    05 5

    029

    3212

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 1012-1/2 [4-pole]

    TM05

    503

    0 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    [m]H

    0

    5

    10

    15

    [m]

    KP 1012-1/260 Hz, n = 1780 rpm

    NPSH

    /8.3

    /9.23

    /10.15

    /11.07

    /12.0

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320

    360[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 1200 1400 Q [m/h]

    0

    40

    80

    120

    160

    200

    240

    [kW]P2

    /8.3

    /8.3

    /9.23

    /9.23

    /10.15

    /10.15

    /11.07

    /11.07

    /12.0

    /12.0

    43

  • Curve charts and technical data

    PACO KP, KPV7

    44

    KP 1015-3/4 [4-pole]

    TM05

    503

    1 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    [m]H

    0

    5

    10

    15

    [m]

    KP 1015-3/460 Hz, n = 1780 rpm

    /11.0

    /12.0

    /13.0

    /14.18

    /15.37

    NPSH

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]0

    100

    200

    300

    400

    500

    600

    700

    800

    900[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 1200 1400 1600 Q [m/h]

    0

    100

    200

    300

    400

    500

    600

    [kW]P2

    /11.0

    /11.0

    /12.0

    /12.0

    /13.0

    /13.0

    /14.18

    /14.18

    /15.37

    /15.37TM

    05 5

    031

    3212

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 1020-3/4 [4-pole]

    TM05

    503

    2 39

    12

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320

    360

    400

    440

    480

    [ft]H

    0

    20

    40

    60

    80

    100

    120

    [ft]NPSH

    0

    20

    40

    60

    80

    100

    120

    140

    [m]H

    0

    5

    10

    15

    20

    25

    30

    35

    [m]

    KP 1020-3/460 Hz, n = 1780 rpm

    /14.0

    /15.4

    /16.75

    /18.25

    /19.6

    NPSH

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Q [US GPM]0

    200

    400

    600

    800

    1000

    1200

    1400

    1600[hp]P2

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 500 1000 1500 2000 2500 Q [m/h]

    0

    200

    400

    600

    800

    1000

    [kW]P2

    /14.0

    /14.0

    /15.4

    /15.4

    /16.75

    /16.75

    /18.25

    /18.25

    /19.6

    /19.6

    TM05

    503

    2 32

    12

    45

  • Curve charts and technical data

    PACO KP, KPV7

    46

    KP 1024-3/4 [4-pole]

    TM05

    503

    3 39

    12

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]0

    50

    100

    150

    200

    250

    300

    350

    400

    450

    500

    550

    600

    650

    700

    750

    [ft]H

    0

    20

    40

    60

    80

    [ft]NPSH

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    [m]H

    0

    5

    10

    15

    20

    [m]

    KP 1024-3/460 Hz, n = 1780 rpm

    /17.0

    /19.0

    /21.0

    /23.0

    /24.8

    NPSH

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]0

    400

    800

    1200

    1600

    2000

    2400

    2800

    3200

    3600[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 500 1000 1500 2000 2500 Q [m/h]

    0

    400

    800

    1200

    1600

    2000

    2400

    [kW]P2

    /17.0

    /17.0

    /19.0

    /19.0

    /21.0

    /21.0

    /23.0

    /23.0

    /24.8

    /24.8

    TM05

    503

    3 32

    12

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 1415-1/2 [4-pole]

    TM05

    503

    4 39

    12

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    [ft]H

    0

    20

    40

    60

    80

    [ft]NPSH

    0

    5

    10

    15

    20

    [m]

    0

    10

    20

    30

    40

    50

    60

    70

    80

    [m]H

    KP 1415-1/260 Hz, n = 1780 rpm

    /12.0

    /13.0

    /13.75

    /14.75

    /15.6

    NPSH

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 Q [US GPM]0

    100

    200

    300

    400

    500

    600

    700

    800

    900[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 500 1000 1500 2000 2500 3000Q [m/h]

    0

    100

    200

    300

    400

    500

    600

    [kW]P2

    /12.0

    /12.0

    /13.0

    /13.0

    /13.75

    /13.75

    /14.75

    /14.75

    /15.6

    /15.6

    TM05

    503

    4 32

    12

    47

  • Curve charts and technical data

    PACO KP, KPV7

    48

    KP 6019-7/8 [6-pole]

    TM05

    503

    5 39

    12

    0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    180

    190[ft]H

    0

    10

    20

    30

    40

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    55

    [m]H

    024681012

    [m]

    KP 6019-7/860 Hz, n = 1180 rpm

    NPSH

    /15.0

    /16.0

    /17.0

    /18.0

    /19.0

    0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 100 200 300 400 Q [m/h]

    0

    20

    40

    60

    80

    100

    [kW]P2

    /15.0

    /15.0

    /16.0

    /16.0

    /17.0

    /17.0

    /18.0

    /18.0

    /19.0

    /19.0

    TM05

    503

    5 32

    12

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 6020-3/4 [6-pole]

    TM05

    503

    6 39

    12

    0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    [ft]H

    0

    10

    20

    30

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70m]H

    0

    2

    4

    6

    8

    [m]

    KP 6020-3/460 Hz, n = 1180 rpm

    /14.0

    /15.5

    /17.0

    /18.5

    /20.0

    NPSH

    0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80[%]Eff

    0 100 200 300 400 500 600 Q [m/h]

    0

    40

    80

    20

    60

    00

    kW]P2

    /14.0

    /14.0

    /15.5

    /15.5

    /17.0

    /17.0

    /18.5

    /18.5

    /20.0

    /20.0TM

    0550

    3632

    12

    49

  • Curve charts and technical data

    PACO KP, KPV7

    50

    KP 8015-3/4 [6-pole]

    TM05

    503

    7 39

    12

    0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [ft]H

    0

    5

    10

    15

    20

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    [m]H

    0

    2

    4

    6

    [m]

    KP 8015-3/460 Hz, n = 1180 rpm

    /9.0

    /10.5

    /12.0

    /13.5

    /15.0

    NPSH

    0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 Q [m/h]

    0

    20

    40

    60

    80

    100

    120

    [kW]P2

    /9.0

    /9.0

    /10.5

    /10.5

    /12.0

    /12.0

    /13.5

    /13.5

    /15.0

    /15.0

    TM05

    503

    7 32

    12

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 8020-5/6 [6-pole]

    TM05

    503

    8 39

    12

    0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    [ft]H

    0

    10

    20

    30

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    [m]H

    0

    2

    4

    6

    8

    [m]

    KP 8020-5/660 Hz, n = 1180 rpm

    /14.0

    /15.31

    /16.62

    /17.94

    /19.25

    NPSH

    0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]0

    50

    100

    150

    200

    250

    300

    350

    400[hp]P2

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 Q [m/h]

    0

    50

    100

    150

    200

    250

    [kW]P2

    /14.0

    /14.0

    /15.31

    /15.31

    /16.62

    /16.62

    /17.94

    /17.94

    /19.25

    /19.25

    TM05

    503

    8 32

    12

    51

  • Curve charts and technical data

    PACO KP, KPV7

    52

    KP 1012-1/2 [6-pole]

    TM05

    503

    9 39

    12

    0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    55

    60

    65

    70

    75

    [ft]H

    0

    5

    10

    15

    20

    25

    [ft]NPSH

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    [m]H

    0

    1

    2

    3

    4

    5

    6

    7

    [m]

    KP 1012-1/260 Hz, n = 1180 rpm

    NPSH

    /8.3

    /9.23

    /10.15

    /11.07

    /12.0

    0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 Q [m/h]

    0

    10

    20

    30

    40

    50

    60

    [kW]P2

    /8.3

    /8.3

    /9.23

    /9.23

    /10.15

    /10.15

    /11.07

    /11.07

    /12.0

    /12.0

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 1015-3/4 [6-pole]

    TM05

    504

    0 39

    12

    0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [ft]H

    0

    10

    20

    30

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    [m]H

    0

    2

    4

    6

    8

    [m]

    KP 1015-3/460 Hz, n = 1180 rpm

    /11.0

    /12.0

    /13.0

    /14.0

    /15.37

    NPSH

    0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]0

    40

    80

    120

    160

    200

    240

    280

    320

    360[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 Q [m/h]

    0

    40

    80

    120

    160

    200

    240

    [kW]P2

    /11.0

    /11.0

    /12.0

    /12.0

    /13.0

    /13.0

    /14.0

    /14.0

    /15.37

    /15.37

    TM05

    504

    0 32

    12

    53

  • Curve charts and technical data

    PACO KP, KPV7

    54

    KP 1020-3/4 [6-pole]

    TM05

    504

    1 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    [m]H

    0

    5

    10

    15

    [m]

    KP 1020-3/460 Hz, n = 1180 rpm

    NPSH

    /14.0

    /15.4

    /16.75

    /18.25

    /19.6

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]0

    50

    100

    150

    200

    250

    300

    350

    400[hp]P2

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 1200 1400 1600 Q [m/h]

    0

    50

    100

    150

    200

    250

    [kW]P2

    /14.0

    /14.0

    /15.4

    /15.4

    /16.75

    /16.75

    /18.25

    /18.25

    /19.6

    /19.6

    TM05

    504

    1 32

    12

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 1024-3/4 [6-pole]

    TM05

    504

    2 39

    12

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    320

    340

    [ft]H

    0

    10

    20

    30

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    [m]H

    0

    2

    4

    6

    8

    [m]

    KP 1024-3/460 Hz, n = 1180 rpm

    NPSH

    /17.0

    /19.0

    /21.0

    /23.0

    /24.8

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 Q [US GPM]0

    100

    200

    300

    400

    500

    600

    700

    800

    900[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]

    0

    100

    200

    300

    400

    500

    600

    [kW]P2

    /17.0

    /17.0

    /19.0

    /19.0

    /21.0

    /21.0

    /23.0

    /23.0

    /24.8

    /24.8

    55

  • Curve charts and technical data

    PACO KP, KPV7

    56

    KP 1220-5/6 [6-pole]

    TM05

    504

    3 39

    12

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    10

    20

    30

    40

    50

    60

    70[m]H

    0

    5

    10

    15

    [m]

    KP 1220-5/660 Hz, n = 1180 rpm

    /13.0

    /14.75

    /16.5

    /18.25

    /20.0

    NPSH

    0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]0

    100

    200

    300

    400

    500

    600

    700

    800

    900[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    0 500 1000 1500 2000 2500 Q [m/h]

    0

    100

    200

    300

    400

    500

    600

    [kW]P2

    /13.0

    /13.0

    /14.75

    /14.75

    /16.5

    /16.5

    /18.25

    /18.25

    /20.0

    /20.0

  • Cur

    ve c

    hart

    s an

    d te

    chni

    cal d

    ata

    PACO KP, KPV 7

    KP 1415-1/2 [6-pole]

    TM05

    504

    4 39

    12

    0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    [ft]H

    0

    20

    40

    60

    [ft]NPSH

    0

    5

    10

    15

    20

    25

    30

    35

    [m]H

    0

    5

    10

    15

    [m]

    KP 1415-1/260 Hz, n = 1180 rpm

    /12.0

    /13.0

    /13.75

    /14.75

    /15.6

    NPSH

    0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]20

    40

    60

    80

    100

    120

    140

    160

    180

    200[hp]P2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90[%]Eff

    20

    40

    60

    80

    100

    120

    140

    [kW]P2

    0 500 1000 1500 2000Q [m/h]

    /12.0

    /12.0

    /13.0

    /13.0

    /13.75

    /13.75

    /14.75

    /14.75

    /15.6

    /15.6

    TM05

    504

    4 32

    12

    57

  • Bare shaft pum

    p

    PACO KP, KPV8

    58

    8. Bare shaft pump

    Dimensional sketch

    DimensionsAll dimensions are in inches.

    TM04

    182

    7 11

    08

    DNs: Suction flangeDNd: Discharge flange

    Pump size DNd DNs HZ A AE D BP B DH/SH W H2095-1/2 2 2-1/2 12-1/4 12 10-1/4 7 7 8-3/4 3-1/2 12 11-16 2013-5/6 2 2-1/2 15-5/8 12 10-1/4 8-1/2 7 8-3/4 3-1/2 12 11/16 3095-7/8 3 4 13 12 10-1/4 8 7 8-3/4 4 12 11/16 3014-7/8 3 4 16-5/8 12 10-1/4 10 9-1/4 11 5 14-1/2 11/16 4012-1/2 4 5 16-1/8 12 10-1/4 10-1/8 9-1/4 11-1/8 4-7/8 14-1/2 11/16 4012-7/8 4 5 16-1/8 12 10-1/4 10-1/8 9-1/4 11-1/8 4-7/8 14-1/2 11/16 4015-9/0 4 5 20 12 10-1/4 13 12 13-3/4 6-1/4 14-1/2 11/16 5012-7/8 5 6 17-5/8 12 10-1/4 14-1/2 10-1/4 12 6-1/2 16-1/2 11/16 5015-9/0 5 6 20-3/4 12 10-1/4 16-1/8 10-1/4 12 6-1/2 17 11/16 6012-3/4 6 8 19-3/4 12 10-1/4 16 10-1/4 12 6-1/2 17 11/16 6015-3/4 6 8 22-3/4 12-1/4 10-1/4 18-1/4 16-1/2 18 7-1/4 20 11/16 6019-7/8 6 8 23-3/4 12 10-1/4 17 12 14 6-3/4 19-1/4 3/4 6020-3/4 6 8 25-5/8 12-1/2 10-1/4 17-3/4 12 14 6-3/4 21-1/2 3/4 8012-5/6 8 10 21-5/8 12 10-1/4 17-1/4 14 15-1/2 6-3/4 20 11/16 8015-3/4 8 10 24-3/4 12-3/4 10-1/4 19 17-1/2 19-1/2 7 20-3/8 11/16 8020-5/6 8 12 28-13/16 25-1/2 19-3/4 20-13/16 16 19-1/4 7-13/16 29-1/2 1-1/8 1012-1/2 10 12 24-3/8 12-3/4 10-1/4 19-13/16 17-1/2 19-1/2 8 20-7/8 11/16 1015-3/4 10 12 24-3/4 18 15 20 12 14 10 23-5/8 7/8 1020-3/4 10 14 30-3/8 25-1/2 19-3/4 23-1/16 16 19-1/4 9-11/16 31-7/16 1-1/8 1024-3/4 10 14 31-3/4 25-1/2 19-3/4 25 16 19-1/4 12 31-7/16 1-1/8 1220-5/6 12 14 30-13/16 25-1/2 19-3/4 25 16 19-1/4 12 31-7/16 1-1/8 1415-1/2 14 16 30-1/2 - - - - - - 28-1/2 -

  • Bar

    e sh

    aft p

    ump

    PACO KP, KPV 8

    Dimensional sketch

    DimensionsAll dimensions are in inches.

    TM04

    182

    7 11

    08

    DNs: Suction flangeDNd: Discharge flange

    Pump size K(WxL) YY X G U N WSCP

    WBPACK SEAL

    2095-1/2 1/4x1/8 8-1/2 8-1/2 5/8 1 2-7/8 8-1/2 21-1/8 19-3/4 16-3/8 2013-5/6 1/4x1/8 10 10 5/8 1 2-7/8 8-1/2 21-1/8 19-3/4 16-3/8 3095-7/8 1/4x1/8 11 11 3/4 1 XE 1-3/16 2-7/8 8-1/2 21-1/8 19-3/4 16-3/8 3014-7/8 3/8x3/16 12 12 7/8 1-1/2 2-3/4 9-7/8 26-1/4 24-1/2 20 4012-1/2 3/8x3/16 12 12 7/8 1-1/2 2-3/4 9-7/8 26-1/4 24-1/2 20 4012-7/8 3/8x3/16 12 12 7/8 1-1/2 2-3/4 9-7/8 26-1/4 24-1/2 20 4015-9/0 3/8x3/16 14-1/16 14-1/16 1 1-1/2 2-3/4 8-1/2 26-1/4 24-1/2 21-3/8 5012-7/8 3/8x3/16 13 13 1 1-1/2 2-3/8 11-3/8 30-1/4 30-1/4 22-1/2 5015-9/0 3/8x3/16 15 14 1 1-1/2 2-3/8 11-7/8 31-1/4 31-1/4 23 6012-3/4 3/8x3/16 16 14 1 1-1/2 2-3/8 11-7/8 31-1/4 31-1/4 23 6015-3/4 3/8x3/16 16 15 1-1/8 1-3/4 3-11/16 11-3/4 36-5/16 36-5/16 29

    6019-7/8 (X5)3/8x3/16(X6)1/2x1/4 17 17 1(X5)1-3/4

    (X6)2(X5)3-11/16

    (X6)3 13-1/4(X5)34-11/16(X6)35-1/2

    (X5)34-3/16(X6)35-1/2 26-1/4

    6020-3/4 1/2x1/4 19 17 1 2-1/8 3-16/16 15-1/2 39-1/8 39-1/8 28-1/2 8012-5/6 3/8x3/16 17 15 1-1/8 1-3/4 3-11/16 13 36-5/16 36-5/16 27-3/4 8015-3/4 3/8x3/16 19 19 1-1/8 1-3/4 3-11/16 11-5/8 37-1/16 37-1/16 30-1/8 8020-5/6 5/8x5/16 22 16-5/16 1-3/8 2-1/2 4-1/4 21-1/2 53-11/16 53-11/16 39-1/8 1012-1/2 3/8x3/16 19-1/2 19-1/2 1-1/8 1-3/4 3-11/16 12-1/8 38-1/16 38-1/16 30-5/8 1015-3/4 1/2x1/4 23 17 1-1/8 2-1/4 6-1/8 17-5/8 41-1/8 41-1/8 30-5/8 1020-3/4 3/4x3/8 26 20 1-3/8 3-1/8 6-7/8 23-3/8 54-11/16 54-11/16 41-5/16 1024-3/4 3/4x3/8 28 24 1-3/8 3-1/8 9-5/16 23-3/8 53-1/2 53-1/2 41-5/16 1220-5/6 5/8x5/16 28 23 1-3/8 2-1/2 4-1/4 21-1/2 54-3/4 54-3/4 39-1/8 1415-1/2 - 25-3/5 21-13/20 - 2-1/2 - - 51-7/10 51-7/10 -

    59

  • The

    nam

    e G

    rund

    fos,

    the

    Gru

    ndfo

    s lo

    go, a

    nd b

    e th

    ink

    inno

    vate

    are

    regi

    ster

    ed tr

    adem

    arks

    ow

    ned

    by G

    rund

    fos

    Hol

    ding

    A/S

    or G

    rund

    fos

    A/S

    , Den

    mar

    k. A

    ll rig

    hts

    rese

    rved

    wor

    ldw

    ide.

    C

    opyr

    ight

    Gru

    ndfo

    s H

    oldi

    ng A

    /S

    98432075 0413ECM: 1109068

    GRUNDFOS Pumps Corporation 17100 West 118th TerraceOlathe, Kansas 66061Phone: +1-913-227-3400 Telefax: +1-913-227-3500

    GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 CanadaPhone: +1-905 829 9533 Telefax: +1-905 829 9512

    Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15Parque Industrial Stiva AeropuertoApodaca, N.L. Mexico 66600Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010

    1. Features and benefitsKPV pumpsNameplate

    2. ApplicationsCommercial systemsIndustrial systemsWater distributionIrrigation and aquaculture

    3. Product rangePump configurations

    4. Performance rangeKP 2-poleKP 4-poleKP 6-pole

    5. ConstructionKP pump, construction X2KP pump, construction X4KP pump, construction X5 and X7KP pump, construction XK and XVKP pump, typical end view - HorizontalStd. components and material specificationMechanical constructionKP Case working pressure limitations at 150 F: Flat-face flanges

    6. Operating conditionsAmbient temperature and altitudeLiquid temperatures and shaft sealsShaft sealPressureFlowKP Impeller Max Sphere SizeKP model number and construction code

    7. Curve charts and technical dataHow to read the curve chartsCurve conditionsPerformance testsWitness testKP 2095-1/2 [2-pole]KP 3095-7/8 [2-pole]KP 4012-1/2 [2-pole]KP 4012-7/8 [2-pole]KP 2095-1/2 [4-pole]KP 2013-5/6 [4-pole]KP 3095-7/8 [4-pole]KP 3014-7/8 [4-pole]KP 4012-1/2 [4-pole]KP 4012-7/8 [4-pole]KP 4015-9/0 [4-pole]KP 5012-7/8 [4-pole]KP 5015-9/0 [4-pole]KP 6012-3/4 [4-pole]KP 6015-3/4 [4-pole]KP 6019-7/8 [4-pole]KP 6020-3/4 [4-pole]KP 8012-5/6 [4-pole]KP 8015-3/4 [4-pole]KP 8020-5/6 [4-pole]KP 1012-1/2 [4-pole]KP 1015-3/4 [4-pole]KP 1020-3/4 [4-pole]KP 1024-3/4 [4-pole]KP 1415-1/2 [4-pole]KP 6019-7/8 [6-pole]KP 6020-3/4 [6-pole]KP 8015-3/4 [6-pole]KP 8020-5/6 [6-pole]KP 1012-1/2 [6-pole]KP 1015-3/4 [6-pole]KP 1020-3/4 [6-pole]KP 1024-3/4 [6-pole]KP 1220-5/6 [6-pole]KP 1415-1/2 [6-pole]

    8. Bare shaft pump