saic-l-2118 rev 0
TRANSCRIPT
-
7/27/2019 SAIC-L-2118 Rev 0
1/1
Name, Initials and Date:T&I Witnessed QC Record Reviewed
Name, Organization,
Initials and Date:
T&I Witnessed QC Record Reviewed
Work Verified
QC Inspector PID Representative
QC Record Reviewed
Performed Inspection Work / Rework May Proceed
Work is Complete and Ready for Inspection:
ACCEPTANCE CRITERIA REFERENCE N/A
WORK PERMIT REQUI
PASS FAIL
EC / PMCC / MCC NO.LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER
EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE
SAUDI ARAMCO INSPECTION LEVEL
ITEM
No.
CONTRACTOR INSPECTION LEVEL
QC Supervisor Proponent and Others
Contractor / Third-Party
REMARKS:
Name, Initials and Date:
Name, Initials and Date:
T&I Witnessed
Name, Initials and Date:
RE-INSP DA
A. General:
A4
Name, Sign and Date:
Quality Record Approved: Work Verified
Construction Representative* PMT RepresentativeWork Verified
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER
SAUDI ARAMCO USE ONLYMH's SP ENT TRAVEL TIMQUANTITY INSP.SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME
PROJ ECT TITLE WBS / BI / J O NUMBER CONTRACTOR / SUBCONTRACTOR
PLANT NO.
SAUDI ARAMCO ID/PID - 2/19/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARAMCO INSPECTION CHECKLISSAIC NUMBER DATE APPROVED QR NUMBER
Inspection of Culvert Crossing SAIC-L-2118 25-May-05 MECH.
SYSTEM ID.
REFERENCE DOCUMENTS:
Saudi Aramco
1. SAES-L-460, Pipeline Crossings Under Roads and Railroads, (30 September, 2003)
2. SAES-B-064, Onshore and Nearshore Pipeline Safety, (30 J anuary, 2002)
Transition from pipeline spacing within corridors and that stipulated at
box culverts shall be made within the road or railroad right-of-way.
SAES-B-064
Para. 10.13
Y =YES N =NO F =FA*Person Responsible for Completion of Quality Work / Test
The minimum spacing between any pipe and the overhead or side
portion of the culvert structure shall be 1.5 pipe diameters, but in no case
less than 1 meter.
SAES-B-064
Para. 10.12
A5
A1
The culvert length or bridge width does exceed 20 times the clearance
between the top of the highest pipeline in a culvert and the ceiling of the
culvert, or from the top of a pipeline to the bottom of the bridge beams.
SAES-L-460
Para. 6.3
A2Box culverts are not used in areas where moving sand can bury the
pipeline unless the pipeline is coated in accordance with SAES-H-002.
SAES-L-460
Para. 6.4
A3
The minimum spacing between any two pipes when pipelines cross
under roads or railroads through box culverts shall be twice the diameter
of the larger pipe.
SAES-B-064
Para. 10.12
Page 1 of 1