OptiX RTN 605 Important Alarms
Pay Special Attention to Following Alarms
BD_STATUSDOWN_E1_AISETH_LOSHARD_BADIF_INPWR_ABNMW_LOFRADIO_FADING_MARGIN_INSUFFT_ALOSRADIO_RSL_LOW
Page 3
BD_STATUS
Alarm Severity Alarm Type Board Possible Causes
Major Equipment Alarm ODU Cause 1: Other alarms are generated. (IF_CABLE_OPEN, VOLT_LOS)Cause 2: The ODU is faulty.
IF_CABLE_OPEN
Alarm Severity Alarm Type Board Possible Causes
Major Equipment Alarm IF Port Cause 1: The IF Cable is Loose or FaultyCause 2: The IF Port of the IDU is DamagedCause 3:The Power Module of ODU is Faulty
VOLT_LOS
Alarm Severity Alarm Type Board Possible Causes
Major Equipment Alarm Power Module, IF Board
Cause 1: The Output Power is AbnormalCause 2: The Input Power is AbnormalCause 3:Lightning Occurs
Page 6
DOWN_E1_AIS
Alarm Severity Alarm Type Board Possible Causes
Major Communication Alarm
E1 Tributary Card Cause 1: The Opposite Side Transmits UP_E1_AIS AlarmCause 2: The IDU is faulty.
UP_E1_AIS
Alarm Severity Alarm Type Board Possible Causes
Minor Communication Alarm
E1 Tributary Board Cause 1:The opposite equipment transmits the AIS signal.Cause 2: The receive unit of the tributary unit at the local site is faulty.
Page 8
T_ALOSAlarm Severity Alarm Type Board Possible Causes
Major Communication Alarm
E1 Tributary Board Cause 1: The interface does not access 2 Mbit/s services.Cause 2: The opposite equipment is faulty.Cause 3:The trunk cable is faulty.Cause 4: The board that reports the alarm is faulty.
Page 9
ETH_LOSAlarm Severity Alarm Type Board Possible Causes
Critical Communication Alarm
Ethernet Board Cause 1:The negotiation fails because the transmit port and receive port work in differentmodes.Cause 2:The link of electrical cable or optical fiber is faulty.Cause 3:The equipment is faulty.
Page 10
IF_INPWR_ABNAlarm Severity Alarm Type Board Possible Causes
Major Equipment Alarm IF Board Cause 1:The IDU is FaultyCause 2:The ODU is FaultyCause 3:The IF Cable is Faulty
Page 11
MW_LOFAlarm Severity
Alarm Type Board Possible Causes
Critical Communication Alarm
IF Board Cause 1:The other alarms are generated.Cause 2: In the case of TDM radio services, the IF working modes at the local site and the opposite site are different. In the case of Hybrid radio services, the channel bandwidth and modulation modes at the local site and the opposite site are different.Cause 3: The working frequency of the ODU at the local site is inconsistent with the working frequency of the ODU at the opposite site.Cause 4:The transmit unit of the opposite site is faulty.Cause 5:The receive unit of the local site is faulty.Cause 6: The receive power of the ODU is abnormal.Cause 7: An interference event occurs.
Page 12
RADIO_FADING_MARGIN_INSUFFAlarm Severity Alarm Type Board Possible Causes
Minor Equipment Alarm ODU Cause 1:The ODU fault at the transmit end causes abnormal transmit power.Cause 2:The direction of the antenna is deflected.Cause 3: Transmission environment changes.Cause 4: The fading margin in the case of rain and fog in the network planning is insufficient.