  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    1/90

    www.huawei.com

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

    Security Level:INTERNAL2007-12-29

    OptiX RTN 600 Product

    Introduction

    RTN---Radio Transmission Node

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    2/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 1Page 1Page 1

    Foreword

    The OptiX RTN 600 is a split-mount digital microwave

    transmission system developed by Huawei. RTN 600

    provides various service interfaces and features flexible

    configuration and easy installation. It can construct a radio

    transmission network that serves as backhaul links for mobile

    communication networks or private networks. The RTN 600

    can also construct a hybrid network that is used to transmit

    SDH, PDH, and Ethernet services together with the OptiXseries optical transmission products of Huawei.

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    3/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2Page 2Page 2

    References

    Product Description and Hardware Description in the OptiX

    RTN 600 ProductManual.

    Digital Microwave Communication principle

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    4/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3Page 3Page 3

    Objectives

    Upon completion of this course, you will be able to:

    Describe the main characteristics of OptiX RTN 600.

    Describe the system structure ,software and hardware

    structure of OptiX RTN 600.

    Know the types of the IDU and their features

    List the functions of boards in the IDU, ODU, Hybrid coupler.

    New introduce slide of V1R3 is remarked by

    Adjust Slide

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    5/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4Page 4Page 4

    Contents

    1. Equipment Overview

    2. Equipment Structure

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    6/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5Page 5Page 5

    Contents

    1. Equipment Overview

    1.1 Equipment Components

    IDU

    ODU

    Antenna

    Intermediate Frequency (IF) Cable

    Hybrid coupler

    1.2 Equipment Characteristics

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    7/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6Page 6Page 6

    Equipment Components

    Hybrid

    CouplerIF Cable

    IDU 620

    ODU

    Antenna

    Pole

    Adjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    8/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7Page 7Page 7

    Equipment ComponentsCont.

    Hybrid

    Coupler

    IF Cable

    IDU 605 2B

    ODU

    Antenna

    Pole

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    9/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8Page 8Page 8

    IDU

    The IDU is the indoor unit of an OptiX RTN 600 system. It

    accesses services, and performs multiplexing/de-

    multiplexing and IF processing of the services.

    The OptiX RTN 600 IDU is available in three types: IDU

    610, IDU 620, and IDU 605.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    10/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9Page 9Page 9

    IDU 610/620

    IDU 610

    IDU 620

    IDU 610 is 1U high and supports

    one microwave direction.

    IDU 620 is 2U high and supports

    maximum four microwave

    directions.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    11/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10Page 10Page 10

    IDU 605

    IDU 605 2B

    IDU 605 1B

    IDU 605 1A

    IDU 605 is 1U high , supports one microwave direction., have there types:

    IDU 605 1A:

    maximum capacity 5 E1

    Support 1+0 configure

    IDU 605 1B:

    maximum capacity 16 E1

    Support 1+0 configure

    IDU 605 2B:

    maximum capacity 16 E1

    Support 1+1configure

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    12/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11Page 11Page 11

    IF Cable

    The IF cable provides -48V power for ODU and transmits the IF signal andODU management signal between IDU and ODU.

    The IDU and ODU are connected by IF jumper and IF Cable:

    IF jumperThe IF jumper is a 2 m RG223 cable. The IF jumper uses a TNC

    connector at one end to connect to the IF board, a type-N connector at the other

    end to connect to the IF cable.

    IF CableBoth end are type-N connector, one end to connect to IF jumper, the

    other end to connect to ODU. There are two types of IF Cable: RG-8U and 1/2

    inch.

    RG-8U cable is used for the distance less than 180 meter.

    1/2 inch cable is used for the distance between 180m and 300m.

    IF transit jumper IF cable

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    13/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12Page 12Page 12

    ODU

    Outdoor unit (ODU) realizes the

    mutual conversion between IF

    analog signal and RF signal.

    6G ODU 7~38G ODU

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    14/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13Page 13Page 13

    Hybrid Coupler

    When two ODUs share one antenna, the ODUs must be

    connected to an RF signal coupler/ splitter (hybrid coupler).

    Then, the hybrid coupler is connected to the antenna.

    738G Hybrid Coupler6G Hybrid Coupler

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    15/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14Page 14Page 14

    Antenna

    The antenna performs the directional transmission and reception

    of RF signals. The main parameters are frequency band,

    diameter and antenna gain.

    Single-polarized antennadual-polarized antenna

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    16/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15Page 15Page 15

    IDU 610/620 Characteristics

    PDH/SDH integrated microwave transmission system.

    The modulation mode and link capacity are set through software.

    Microwave link supports the SNCP (IF0 Board not support

    SNCP

    Except for SL4IF0IFXEMS6 not support IDU 610

    the other boards of IDU 610 and IDU 620 are compatible each

    other.

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    17/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16Page 16Page 16

    IDU 610/620 Characteristics (cont.)

    IFX board support XPIC function

    Support N+1 protection and REG function

    Synchronous data interface /Orderwire spanning function

    SL61SCCVER.C

    The external clock interface supply 2M overhead , it can be used

    as the wayside service interface, or can transparently transmit

    DCC bytes, synchronous data overhead bytes, asynchronous data

    overhead bytes, and orderwire overhead bytes.

    Support STM-4 MSP

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    18/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17Page 17Page 17

    IDU 605 Characteristics

    PDH microwave transmission platform

    The modulation mode and link capacity are set through software.

    Microwave link not support SNCP

    Integrative box equipment

    orderwire spanning, orderwire addressing calls, orderwire group

    calls.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    19/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18Page 18Page 18

    IDU Compare

    Item IDU 605 IDU 610 IDU 620

    RF configuration mode 1+0IDU 605

    1A/1B

    1+1IDU 605 2B

    1+0 1+0,1+1, N+1, XPIC

    IF Board IF logical board (IF0) IF1 IF0, IF1, IFX

    Maximum capacity (single

    carrier)

    5 E11A

    16 E11B/2B

    STM-1

    Pluggable board Not support support

    Microwave type PDH SDH/PDH

    Microwave modulation

    scheme

    QPSK QPSK/16QAM/32QAM/64QAM/128Q

    AM

    Service type E1 SDHPDHE1E3DS3 and

    Ethernet services

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    20/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19Page 19Page 19

    Questions

    What are the components of OptiX RTN 600? What

    are the functions of them? What about the connection

    relation among the components?

    What types do the optiX RTN 600 have What are the

    characteristics of each type IDU?

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    21/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20Page 20Page 20

    Contents

    1. Equipment Overview

    2. Equipment Structure

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    22/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21Page 21Page 21

    Contents

    Equipment Structure

    2.1 System Diagram

    2.2 Software Structure

    2.3 IDU 605 Structure and Boards

    2.4 IDU 610/620 Structure and Boards

    2.5 ODU Interfaces and Parameters

    2.6 Hybrid coupler Parameters

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    23/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22Page 22Page 22

    Software Structure

    NM software

    Host software

    Board softwareODU

    In the OptiX RTN 600, all the board

    software and host software are integrated

    together and run on the SCC board.

    SCC

    ODU is regarded as a logical board. The

    ODU board software in the SCC board

    manages and controls the ODU hardware

    through the management signal between

    the IDU and ODU.

    EMS6

    EMS6 board has independent boardsoftware, which runs in the CPU of the

    EMS6 board.

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    24/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23Page 23Page 23

    Contents

    Equipment Structure

    2.1 System Diagram

    2.2 Software Structure

    2.3 IDU 605 Structure and Boards

    2.4 IDU 610/620 Structure and Boards

    2.5 ODU Interfaces and Parameters

    2.6 Hybrid coupler Parameters

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    25/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24Page 24Page 24

    IDU Structure IDU 605 1A

    IDU 605 is 1U high and

    adopts the nature heat

    dissipation mode.

    Support 1+0 configuration. IDU 605 1A

    IDU 605 1A logic board configuration

    NotePF1 support5E1, E1

    interface is DB44, the

    physical interface can

    access 8E1,butonlyuse

    1~5E1, 6~8E1 notbe

    processed.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    26/90

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    27/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26Page 26Page 26

    IDU Structure IDU 605 1B

    IDU 605 is 1U high and

    adopts the nature heat

    dissipation mode.

    Support 1+0 configuration.IDU 605 1B

    IDU 605 1B logic board configuration

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    28/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27Page 27Page 27

    IDU 605 1B Front Panel Interface

    SynchronousData

    Interface

    Main

    power

    switchIndicators

    Boolean

    interface 1~16E1

    Interfaces

    ODU

    Interfaces

    Order

    wire

    Interface

    Asynchronous

    data Interface

    NM

    Serial

    Port

    NM

    InterfacePower

    interfaces

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    29/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28Page 28Page 28

    IDU Structure (IDU 605 2B

    IDU 605 is 1U high and

    adopts the nature heat

    dissipation mode.

    Support 1+1 configuration.

    IDU 605 2B

    IDU 605 2B logic board configuration

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    30/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29Page 29Page 29

    IDU 605 2B Front Panel Interface

    Synchronous

    Data InterfaceMain

    power

    switchIndicators

    Boolean

    interface

    1~16E1

    Interfaces

    ODUInterfaces

    Order

    wire

    Interface

    Asynchronous

    data Interface

    NM

    Serial

    Port

    NM

    InterfacePower

    interfaces

    ODU

    power

    switches

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    31/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30Page 30Page 30

    IDU 605 Indicators Indicators of IDU 605 1A and IDU 605 1B:

    Name Color and meaning

    PWRRED The system has POWER_ALM

    GREENThe system doesnt has POWER_ALM

    IDU

    On for 100 ms and off for 100 ms alternately (green) :When the board

    is being powered on or being reset, the software is being loaded.On for 500 ms and off for 500 ms alternately (green) :The board is in

    the BIOS holdover state. The NE software does not exist or is not

    running

    RED A critical or major alarm occurs in the services.

    YELLOW: A minor or warning alarm occurs in the services.

    GREEN The IDU works normally.

    ODU

    RED : A critical or major alarm occurs in the ODU, or the ODU has no

    power access.

    YELLOW: A minor or warning alarm occurs in the ODU.

    GREEN The ODU works normally.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    32/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 31Page 31Page 31

    IDU 605 Indicators (Cont.)

    Indicators of IDU 605 2B:

    Name Color and meaning

    PWR The same as IDU 605 1A andIDU 605 1B

    IDU The same as IDU 605 1A andIDU 605 1B

    ODU1Indicators of the backup ODU(slot17)The same as IDU 605 1A andIDU

    605 1B

    ODU2Indicators of the main ODU(slot18)The same as IDU 605 1A andIDU

    605 1B

    ACT1The Indicators of the standby IF board(slot7),

    on( green) The backup IF board is in active state

    off The backup IF board is in standby state

    ACT2The Indicators of the main IF board(slot8), color :

    On (green): The main IF board is in active state

    off The main IF board is in standby state

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    33/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 32Page 32Page 32

    IDU 605 Logical Board

    Logical Board Name Full Name Logical Slot

    PW48B 48 V power board Slot 1

    SCC System control and

    communication board

    Slot 2

    EOW Orderwire board Slot 3

    PF1 5xE1 tributary board Slot 4

    PH1 16xE1 tributary board

    IF0 PDH IF board Slot 8IDU605 1A/1B)

    Slot7/8IDU605 2B)

    An IDU 605 is composed of one system board and one power board.

    Each functional unit on the physical boards of the IDU 605

    corresponds to a logical board and is allocated with a logical slot.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    34/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 33Page 33Page 33

    IDU 605 Signal Processing Flow

    IDU 605 not support build-in ADM function, the signal need

    not through the cross-connect process, multiplexes E1

    service signals into microwave frame signals directly. The

    signal processing flow as following:

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    35/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 34Page 34Page 34

    IDU 605 Clock Characteristics

    The clock tracing neednt to be configured. It is auto-Negotiation,

    and clock tracing as the following results:

    In a point-to-point network which the NE use IDU 605, the clock

    trace auto-negotiation result is the high site NE as free-runmodes and the low site NE trace the high site clock sourse.

    One site that the NE use IDU 605, the opposite site that the NE

    use IDU 620, the result of clock trace is the IDU 605 clock trace

    the IDU 620s clock source.

    NoteThe IDU620 clock cannotbe setto trace the IDU605 clock. Otherwise

    the clock will self-lock.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    36/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 35Page 35Page 35

    IDU 605 OtherCharacteristics

    Supports the setting of the impedance of E1 signals through

    the software (75-ohm or 120-ohm).

    Supports 1+1 protection for the input power.

    Supports the group call function of the orderwire, the group

    number is 888. The orderwire number also can be set as

    designing.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    37/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36Page 36Page 36

    Contents

    Equipment Structure

    2.1 System Diagram

    2.2 Software Structure

    2.3 IDU 605 Structure and Boards

    2.4 IDU 610/620 Structure and Boards

    2.5 ODU Interfaces and Parameters

    2.6 Hybrid coupler Parameters

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    38/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 37Page 37Page 37

    IDU Structure ( IDU 610)

    IDU 610 is 1U high and adopts

    the nature heat dissipation mode.

    Support 1+0 configuration.

    EXT slot3

    PXC slot1

    EXT slot4

    SCC slot2

    Note: The slotnumbering rule is

    from bottom to up

    and left to right.

    IF boardLine board /tributary

    board/data board

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    39/90

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    40/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 39Page 39Page 39

    IDU Board -- IF Board IF1

    ODU power

    supply switch

    IF cable interface Indicators

    The IF board receives and transmits 1x IF signal. It realizes the

    conversion between baseband digital signal and IF signal, it also

    provides -48V DC power supply and management signal to the ODU.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    41/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 40Page 40Page 40

    IDU Board -- IF Board IF0

    IF cableinterface

    ODU powersupply switch

    Indicators

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    42/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 41Page 41Page 41

    IDU Board -- IF Board IFX

    IF cable

    interface

    XPIC input /output

    signal port

    ODU power

    supply switch

    Indicators

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    43/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 42Page 42Page 42

    IF Board -- Board Installation

    slot20 PXC slot3

    PXC slot1

    EXT slot4

    SCC slot2

    EXT slot7

    EXT slot3

    PXC slot1

    EXT slot4

    SCC slot2

    IDU 610

    IDU 620

    EXT slot5

    EXT slot8

    EXT slot6

    Paired Slots

    Paired Slots

    No limitation for board installation under HSB configuration.

    Only installing IF boards in paired slots under SD or FD configuration.

    Recommended

    installationsequence for IF

    boards

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    44/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 43Page 43Page 43

    IF1 Board -- IF PerformanceAdjust Slide

    R1 version, the IF1 board support 7 working mode.

    ItemPerformance

    4 X E1 8 X E1 16 X E1 STM-1

    Modulation

    mode

    QPSK 16QAM QPSK 16QAM QPSK 16QAM 128QAM

    Channel

    spacing

    (MHz)

    7 3.513.75 /14

    a7

    27.5/

    28 b

    13.75 /14

    a27.5 / 28 b

    Coding

    scheme

    PDH signal is coded through the Reed-Solomon (R-S).

    SDH signal is coded through the Trellis-Coded Modulation (TCM) and R-

    S.

    Remarks

    a: At the 18G band, the channel spacing is 13.75MHz, At other bands,

    the channel spacing is 14MHz.

    b: At the 18G band, the channel spacing is 27.5MHz. At other bands, the

    channel spacing is 28MHz.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    45/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 44Page 44Page 44

    IF1 Board -- IF Performance

    For R2, the IF1 board add 8 types of working mode.

    Item Performance

    Capacity E3 22E1 26E1 32E1 35 E1 44 E1 53 E1

    Modulation

    modeQP

    SK

    16

    QAM

    32

    QAM

    64

    QAM

    128

    QAM

    16

    QAM

    32

    QAM

    64

    QAM

    Channel

    spacing(MHz)

    28 14 14 14 14 28 28 28

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    46/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 45Page 45Page 45

    IF0 Board -- IF Performance

    ItemPerformance

    16 E1 10 E1 5 E1 2 E1

    Modulationmode

    QPSK QPSK QPSK QPSK

    Channel

    spacing

    (MHz) 28 14 7 3.5

    IF0 board support four types of working mode: 16E1, 10E1, 5E1,

    2E1modulation mode only support QPSK.

    NoticeThe IF0 board and the IF1 board cannot interconnection, even though

    they are in the same IF working mode.

    IF0 board is use for interconnection with IDU 605

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    47/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 46Page 46Page 46

    IFX Board -- IF Performance

    IFX support one working mode: STM-1, 128QAM, 28MHz

    coded through the Trellis-Coded Modulation (TCM) and R-S

    Support XPIC function

    In the service of STM-1 mode, when the XPIC function is disabled,

    the IFX can be interconnected to IF1, but it isnt recommended.

    NoteWhen the XPIC function is disabled, the XPIC INportand

    XPICOUTportmustbe looped back byusing an XPIC cable.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    48/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 47Page 47Page 47

    IF Board -- IF Signal Parameters

    Item Performance

    IF signal

    Transmitting frequency

    (MHz)

    350

    Receiving frequency

    (MHz)

    140

    Impedance (ohm) 50

    ODUmanagement

    signal

    Modulation mode ASK

    Transmitting frequency(MHz)

    5.5

    Receiving frequency

    (MHz)

    10

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    49/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 48Page 48Page 48

    IF Board -- Indicators

    The space link is faulty.On

    The space link is normal.OnLINK

    No services are configured.Off

    The service has a minor or remote alarm.On

    The service has a critical or major alarm.On

    The service is normal.On

    SRV

    The board is not working, not

    created, or has no input power.Off

    The board hardware is faulty.On

    The board is working normallyOn

    STAT

    MeaningStatusIndicator

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    50/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 49Page 49Page 49

    IF Board Indicators (Cont.)

    Indicator Status Meaning

    ODUOn The ODU is normal.

    On The ODU is faulty.

    BER

    On The microwave BER exceeds the

    threshold.Off The microwave BER does not exceed

    the threshold.

    RMT

    On The remote equipment has a Remote

    Defect Indication (RDI).

    Off The remote equipment has no RDI.

    ACTOn The board is in active state.

    Off The board is in standby state.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    51/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 50Page 50Page 50

    IDU Board -- Tributary Board PH1

    Indicator 1-8 channel E1

    DB44

    interfaces

    9-16 channel E1

    DB44 interfaces

    The tributary board PH1 processes 16 channel E1 signals and

    provides the E1 interface.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    52/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 51Page 51Page 51

    IDU Board -- Tributary Board PD1

    The tributary board PD1 processes 32 channel E1 signals and

    provides the E1 interface.

    116 E1

    MDR68 interface1732E1

    MDR68 interfaceindicator

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    53/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 52Page 52Page 52

    IDU Board -- Tributary Board PL3

    The tributary board PL3 processes 3 channel E3/DS3 signals andprovides the E1 interface.

    PL3 not support the E3 and DS3 services hybrid configured.

    Select the type of the accessed service signal as E3 or DS3 through

    software.

    indicator SMB

    interface

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    54/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 53Page 53Page 53

    Tributary Board -- Types

    16-channel E1

    interface

    75 ohm

    PH1A

    8-channel

    E1 interface

    75 ohm

    PO1A PO1BPH1B

    16-channel E1

    interface

    120 omh

    8-channel E1

    board

    120 ohm

    Four groups ofjumpers

    determine theimpedance.

    Front

    panel

    The board interface impedance

    is selected through the jumper:

    If there is a jumper, the

    impedance is 75 ohm.

    If there is no jumper, the

    impedance is 120 ohm.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    55/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 54Page 54Page 54

    Tributary Board -- Types (cont.)

    32-channel E1

    interface

    75 ohm

    PD1A PD1B

    32-channel

    E1 interface

    120 omh

    Eight groups

    of jumpers

    determine the

    impedance.

    Front

    panel

    PD1 board interface impedance is selected

    through the jumper:

    If there is a jumper, the impedance is 75

    ohm.

    If there is no jumper, the impedance is

    120 ohm.

    PL3 board interface impedance cannot

    changed through the jumper

    PL3

    3-channel

    E3/DS3 interface

    75 ohm

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    56/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 55Page 55Page 55

    Tributary Board -- Board installation

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    EXT slot7

    PXC slot1

    EXT slot4

    SCC slot2

    IDU 610

    IDU 620

    EXT slot5

    EXT slot8

    EXT slot6

    Recommended

    installation

    sequence for TU

    boards

    EXT slot4

    EXT slot3

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    57/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 56Page 56Page 56

    Tributary Board -- Indicators

    Indicator Status Meaning

    STAT

    On The board is working normally.

    On The board hardware is faulty.

    Off The board is not working, or created, or has no input power.

    SRV

    On The service is normal.

    On The service has a critical or major alarm.

    On The service has a minor or remotealarm.

    Off No services are configured.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    58/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 57Page 57Page 57

    IDU Board -- Line Board SD1/SDE

    SMB

    electricalinterface

    LC optical

    interface

    The line board processes 1-2 channel STM-1 signal and

    provides STM-1 optical or electrical interface.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    59/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 58Page 58Page 58

    IDU Board -- Line Board SL4

    The SL4 line board processes 1 channel STM-4 signal and provides

    STM-4 optical interface.

    LC optical

    interfaceindicator

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    60/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 59Page 59Page 59

    Line Board -- Types

    SD1

    Dual-port STM-1

    optical interface

    Ie-1

    interface

    S-1.1

    interface

    L-1.1

    interfaceL-1.2

    interface

    SL1

    Single- port STM-1

    optical interface

    Ie-1

    interface

    S-1.1

    interface

    L-1.1

    interfaceL-1.2

    interface

    SDE

    dual-port STM-1

    electrical interface

    SLE

    Single-port STM-1

    electrical interface

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    61/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 60Page 60Page 60

    Line Board Types (cont.)

    SL4 line board support three optical module

    SL4

    Single STM-4 optical interface

    S-4.1

    interface

    L-4.1

    interface

    L-4.2

    interface

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    62/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 61Page 61Page 61

    Line Board -- Board installation

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    PXC slot1

    EXT slot4

    SCC slot2

    IDU 610

    IDU 620

    EXT slot5

    EXT slot8

    EXT slot6

    EXT slot4

    EXT slot3

    EXT slot7

    Recommended

    installation

    sequence for LU

    boards

    Note: Onlyslot6/slot8 supportSL4

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    63/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 62Page 62Page 62

    Line Board -- Indicators

    Indicator Status Meaning

    STAT

    On The board is working normally.

    On The board hardware is faulty.

    Off The board is not working, or created, or no power

    supply.

    SRV

    On The service is normal.

    On The service has a critical or major alarm.

    On The service has a minor or remote alarm.

    Off No services are configured.

    LOS1

    On No.1 opt. port on the SL1/SD1 board has a R_LOSalarm.

    Off No.1 opt. port on the SL1/SD1 board has no R_LOS

    alarm.

    LOS2On No.2 opt. port on the SD1 board has a R_LOS alarm.

    Off No.2 opt. port on the SD1 board has no R_LOS alarm.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    64/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 63Page 63Page 63

    Line Board -- Indicators

    LOS

    on opt. port on the SL1/SD1 board has a

    R_LOS alarm.

    off opt. port on the SL1/SD1 board has no

    R_LOS alarm.

    Note: All the line board have the STAT and SRV indicator.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    65/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 64Page 64Page 64

    IDU Board -- Ethernet Board EFT4

    EFT4 is a Ethernet transparent transmission board. It receives,

    transmits and processes four-channel Ethernet signals.

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    EXT slot7

    PXC slot1

    EXT slot4

    SCC slot2

    IDU 610

    EXT slot5

    EXT slot8

    EXT slot6

    EXT slot4

    EXT slot3

    IDU 620

    Recommended

    installation

    sequence forEFT4 boards

    R2 N SlidR2 N Slid

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    66/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 65Page 65Page 65

    IDU Board -- Ethernet Board EMS6

    The EMS6 accesses 4xFE signals and 2xGE/FE signals, and

    supports transparent transmission services and Layer 2 switching.

    Provides GE optical interfaces or GE electrical interfaces by using two

    SFP modules. The GE electrical interface is compatible with the FE

    electrical interface.

    Supports an uplink bandwidth of 2xVC-4s.

    IDU 620

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    EXT slot8

    EXT slot6

    EXT slot4

    Recommended

    installation

    sequence for

    EMS6 boards

    EXT slot7

    EXT slot5

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    67/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 66Page 66Page 66

    Power Cross-Connection Clock

    Board -- PXC

    IndicatorIDU

    Power

    switch

    External clock/

    Wayside

    Interface/Overhea

    d data channel

    Power input

    interface

    The PXC board realizes the cross-connection (1616 VC4) and

    clock functions , it also provides the DC power for other boards.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    68/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 67Page 67Page 67

    PXC -- Board Installation

    IDU 610

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    EXT slot7

    IDU 620

    EXT slot5

    EXT slot8

    EXT slot6

    EXT slot4

    PXC slot1

    EXT slot4

    SCC slot2

    EXT slot3

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    69/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 68Page 68Page 68

    PXC -- Indicators

    Indicator Status Meaning

    STAT

    On The board is working normally.

    On The board hardware is faulty.

    Off The board is not working, or not created, or has

    no input power.

    PWR

    On The power is normal.

    On +3.3V power fault or -48V input power abnormal

    Off No input power.

    SYNC

    On The clock is normal.

    On The clock source is lost or the switch exists.

    ACTOn The board is in active state.

    Off The board is in standby status.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    70/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 69Page 69Page 69

    IDU Board -- SCC

    SCC provides system control and communication functions, auxiliary

    interfaces management and standby internal power module.

    Indicators

    Indicator

    test button

    Reset

    button

    NM serial

    port

    NM

    interface

    NM cascaded

    interface

    Order wire

    Asynchronous

    data and

    Boolean

    interface

    Flash

    memory

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    71/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 70Page 70Page 70

    SCC Board -- Board Installation

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    EXT slot7

    IDU 610

    IDU 620

    EXT slot5

    EXT slot8

    EXT slot6

    EXT slot4

    PXC slot1

    EXT slot4

    SCC slot2

    EXT slot3

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    72/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 71Page 71Page 71

    SCC Board -- NM Cable Connection

    The SCC board sets the NE ID through the software. The initial NE ID

    is set to 49136 by default.

    The IP address of NE is also set through the software. The IP address is

    set to 129.9.0.ID by default.

    NMS

    Connected by

    Ethernet cable

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    73/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 72Page 72Page 72

    SCC Board -- Wrong Connections

    Multiple NEs are

    cascaded as a

    loop.

    Self-loop of

    single NE

    The connectionwill cause NE

    reset frequently.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    74/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 73Page 73Page 73

    SCC Board -- Indicators

    Indicato

    r

    Status Meaning

    STAT

    On The board is working normally.

    On The board hardware is faulty.

    Off The board is not working, or not created, or has no input power.

    PROG

    On 100 ms and off

    100 ms

    During the board power-on/reset, loading

    the software.

    On 300 ms and off

    300 ms

    The board software is introduced through

    the BIOS during the power-on/reset.On Initialize the upper layer software.

    On 100 ms and off

    100 ms

    During the board power-on/reset,

    BOOTROM self-test fails.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    75/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 74Page 74Page 74

    SCC Board -- Indicators

    Indicato

    r

    Status Meaning

    PROG

    On During the board power-on/reset, the memory self-

    test fails or the upper layer software loading fails, or

    during the board running, the logical file and software

    are lost.

    Off The software is normal.

    ALM

    On The system is normal.

    On The system has a critical or major alarm.

    On The system has a minor alarm.

    Off The system has no input power.

    MANT

    On The system is in maintenance state ( that is, loop-

    back, laser power-off, and ODU transceiver mute)

    Off The system is in working state.

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    76/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 75Page 75Page 75

    IDU Board -- Fan Board (FAN)

    Indicator

    slot

    20 PXC slot3

    PXC slot1 SCC slot2

    EXT slot5

    EXT slot8

    EXT slot6

    EXT slot4

    EXT slot7

    Fan direction

    Indicator Status Meaning

    FAN

    On The fan is working normally.

    On The board is faulty.

    Off The board has no input power.

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    77/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 76Page 76Page 76

    IDU BoardsSummary

    Board Support IDU Type Explain

    IF1A/IF1B IDU 610/IDU 620 receives and transmits 1x IF signal. It

    realizes the conversion between baseband

    digital signal and IF signal, it also provides -

    48V DC power supply and management

    signal to the ODU.

    IF0A/IF0B IDU 620

    IFX IDU 620

    PH1 IDU 610/IDU 620 8E1tributary boardprovide E1 interface.

    PO1 IDU 610/IDU 620 16E1tributary boardprovide E1 interface.

    PD1 IDU 610/IDU 620 32E1tributary boardprovide E1 interface.

    PL3 IDU 610/IDU 620 3E3/DS3 tributary boardprovide E3/DS3

    interface.

    R2 New SlideR2 New Slide

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    78/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 77Page 77Page 77

    IDU BoardsSummary (cont.)

    Board Support IDU Type Explain

    SD1 IDU 610/IDU 620 2STM-1 line board, provide STM-1 optical interface

    SDE IDU 610/IDU 620 2STM-1 line board, provide STM-1 electrical

    interface

    SL1 IDU 610/IDU 620 1STM-1 line board, provide STM-1 optical interface

    SLE IDU 610/IDU 620 1STM-1 line board, provide STM-1 electrical

    interface

    SL4 IDU 620 1STM-41 line board, provide STM-4 optical interface

    EFT4 IDU 610/IDU 620 4-port 10M/100M Ethernet transparent transmission

    board.

    EMS6 IDU 620 supports transparent transmission services and Layer

    2 switching services

    R2 New SlideR2 New Slide

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    79/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 78Page 78Page 78

    IDU BoardsSummary (cont.)

    Board Support IDU Type Explain

    SCC IDU 610/IDU 620 SCC provides system control and communication

    functions

    PXC IDU 610/IDU 620 Power Cross-Connection Clock Boardprovide

    power supply, cross, clock function.

    FAN IDU 620 FAN board

    R2 New SlideR2 New Slide

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    80/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 79Page 79Page 79

    Contents

    Equipment Structure

    2.1 System Diagram

    2.2 Software Structure

    2.3 IDU 605 Structure and Boards

    2.4 IDU 610/620 Structure and Boards

    2.5 ODU Interfaces and Parameters

    2.6 Hybrid coupler Parameters

    R2 New SlideR2 New Slide

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    81/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 80Page 80Page 80

    ODU TypesThe OptiX RTN 600 ODU is available in three types: Standard Power,

    High Power, and Low capacity for PDH.

    Item Description

    Standard Power

    ODU

    High Power ODU Low Capacity for

    PDH ODU

    ODU series SP and SPA HP LP

    Frequency band 6/7/8/11/13/15/18/2

    3/26/38GHz

    7/8/11/13/15/18/23/2

    6/32/38 GHz

    7/13/15/18/23

    GHz

    Microwave type SDH/PDH PDH

    Microwave

    modulation scheme

    QPSK/16QAM/32QAM/64QAM/128QAM QPSK/16QAM

    R2 New SlideR2 New Slide

    Adjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    82/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 81Page 81Page 81

    ODUInterface

    6 GHz SP series ODUs are coaxial interfaces

    738 GHz ODUs are waveguide

    interfaces

    The ODUs are classified into the ODU with the waveguide interface and the ODUwith the coaxial interface according to the type of the antenna interface of the ODU.

    Adjust Slide

    R2 New SlideR2 New Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    83/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 82Page 82Page 82

    The Match Relation between IDU and ODU

    IDU IF boardODU

    SeriesDescription

    IDU 605 IF0 LP/SP

    IDU 605 match with the LP-ODU firstly. If

    the LP-ODU not satisfy the requirement, than

    IDU 605 match with the SP-ODU.

    IDU 610 IF1A/IF1B SPNot support HP ODU in the result of the natureheat dissipation mode.

    IDU 620

    IF1A/IF1B SP/HP None

    IF0 LP/SP None

    IFX SP/HP None

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    84/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 83Page 83Page 83

    ODU -- Main Performance

    ODU6G38G7G

    ITEM L6 U6 7 8 11 13 15 18 23 26 32 38

    HPTX

    Power.

    maximum

    30 30 28 26 26 25.5 25 25 23 23

    SPTX

    Power

    maximum

    26 26 25.5 25.5 24.5 24.5 24.5 24 22.5 22 20.5

    LPTX

    Power

    maximum

    27 27 25 25 23.5 23.5 23

    Maximum

    receive

    power

    dBm

    -20

    Tx Frequency Stability (ppm): 5

    jj

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    85/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 84Page 84Page 84

    Contents

    Equipment Structure

    2.1 System Diagram

    2.2 Software Structure

    2.3 IDU 605 Structure and Boards

    2.4 IDU 610/620 Structure and Boards

    2.5 ODU Interfaces and Parameters

    2.6 Hybrid coupler Parameters

    jj

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    86/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 85Page 85Page 85

    Hybrid Couplerjj

    Hybrid coupler -- Main

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    87/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 86Page 86Page 86

    Hybrid coupler -- Main

    PerformanceItem Performance

    Loss (dB) 3.30.3 (3 dB balanced hybrid coupler)

    1.7 (6 dB unbalanced hybrid coupler with waveguide

    interfaces)

    1.9 (6 dB unbalanced hybrid coupler with coaxial

    interfaces)

    Ripple of loss (dB) 0.5

    Degree of coupling (dB) 3.30.3 (3 dB balanced hybrid coupler)

    6.50.6 (6 dB unbalanced hybrid coupler)

    Degree of separation (dB) 20Voltage standing wave

    ratio (VSWR)

    1.2

    Power capacity (W) 8

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    88/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 87Page 87Page 87

    Summary

    OptiX RTN 600 equipment structure

    Software Structure host and board software are integrate in SCC board,

    ODU as logical board.

    IDU divide into three types: IDU 605, IDU 610, IDU 620

    IDU 610/620 through configure different board to realize the required function:

    IF BoardIF1AIF1BIF0AIF0BIFX

    Line BoardSL1SD1SLESDESL4

    Tributary BoardPH1PO1PD1PL3

    Data BoardEFT4EMS6

    Power Cross Connect BoardPXC

    System Communication and Control boardSCC

    Fan boardFAN

    IDU 605 is available in three types: IDU 605 1A, IDU 605 1B

    ODUinterfacemain performance

    Hybrid Couplerinterfacemain performance.

    Adjust SlideAdjust Slide

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    89/90

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 88Page 88Page 88

    Summary

    Contents Review

    Main characteristics

    System Structure, Software and Hardware Structure

    Board Functions and Signal flow in the IDU

    ODU and Hybrid coupler Features and Functions

    Equipment Level Protection Actions and Signal flow

    Microwave Link Protection Actions and Signal flow

  • 8/3/2019 OptiX RTN 600 Product Introduction-A

    90/90

    Thank youwww.huawei.com