2

Adret Company Profile

During 1991, a small company, Electronic Repairs & Manufacture was founded with its main aim to provide a service to the Electrical Test industry as a service and repairs company for the then “Ferret” and “Biccotest” range of Cable Fault Location instruments. ERM soon started to do repairs and service work to other brands of test equipment. We realized that there was a great need in the industry for a company that could supply a good, reliable and economic ser-vice to all players in the industry. During 1993, when South Africa started going through a series of political changes, the value of our currency depreciated so much that it became very difficult for consumers to buy im-ported test equipment. We decided that the time was right to start developing our own range of equipment and the original ERM then became Southern Africa Fault Location. We started by developing our very first ground microphone system, which saw the light dur-ing 1996. Our range grew to as many as thirty different products, ranging from Ground Micro-phone systems to Surge Generators and Pre-Location Scopes. During 2004 we were awarded our ISO9001 certification and is still maintaining this to date. We produce around 95% of the building blocks for our equipment in-house within our Alberton factory. We founded new companies and merged with other industry players to form the Adret Group of companies during 2007. The Adret Group of Companies consist of Southern Africa Fault Location (development and production of new test equipment), Cables For Africa (cable fault location and diagnostic testing), Surge Gen Technologies (service and repairs) and Indlovu En-terprises (sales and marketing for the group). We have built the company over the past 21 years and has and has earned a reputation in the industry as the company that delivers the very best service. We are available 24/7 to our cus-tomers. Over the past years our export market has steadily grown and today we export test equip-ment to Australia, UK, USA, Malaysia, Singapore, Saudi Arabia, Hong Kong and many others. Adret Test Equipment is uniquely positioned in South Africa as the only manufacturer of such equipment in the Southern Hemisphere. Our location in the SADC region offers a lot of scope in the development op the African continent.

Page 3: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

3

Adret Test Equipment Southern Africa Fault Location manufactures a large range of Pow-er Cable Fault Location and Proof Test Equipment.

www.adret.co.za Email: [email protected]

Indlovu Enterprises Indlovu Enterprises are the Sales and Marketing arm of the Adret Group of Companies. We supply all items in this booklet and many more. All sales related queries will be handled as soon as possible.

www.undlovu.co.za Email: [email protected]

Cables For Africa Cables For Africa is the service arm of the Adret Group of Compa-nies. We provide services such as Cable Fault Location, Proof Testing and Diagnostic Testing.

www.cfa.co.za Email: [email protected]

Surge Gen Technologies Surge Gen Technologies is the support arm for the Adret Group of Companies. We provide repairs, service and calibration work to Adret and all other brands of Cable Fault Location and test equip-ment.

www.sgen.co.za Email: [email protected]

Page 4: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

4

Ove

rvie

w

ADRET GROUP

Power Cable Fault Location Equipment

Southern Africa Fault Location produces test equipment for the Power Cable Fault Loca-tion industry. We also produce a range of High Voltage Proof Test Instruments and vari-ous safety devices for the Cable Test Industry

Surge Generators 13 Surge Generators are produced in a range from 5kV to 32kV with discharge energy ranging from 500 Joules to 3500 Joules. Combination Systems are available that enables the user to Pre-Locate high resistance faults.

Ground Microphone Systems 21 Ground Microphone Systems are available in a basic analogue and a high end digital range. In the higher end systems selectable filters and time of flight measurements are standard fea-tures.

Fault Pre-Location Scopes 23 Fault Pre-Location scopes are used to pre deter-mine the distance to a fault. It analyses the impedance of the cable using TDR technology. To pre-locate high resistance fault, the unit is connected to the HT pulse, which temporarily lowers the fault resistance.

Cable Sheath Fault Location 26 Sheath Fault Locators are used to determine the integrity of cable sheaths. The “Pool of Potential” method is used to “Pin-Point” where tiny holes are present in the cable sheath.

Cable Fault Conditioning Unit 29 Sometimes it might be necessary to reduce the resistance of certain cable faults to facilitate better Fault Pre-Location results.

Page 5: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

5

Ove

rvie

w

ADRET GROUP

Mining Cable Fault Location Equipment

Southern Africa Fault Location produces test equipment for the Mining Power Cable Fault Location industry. Our Partial Break Test instruments will locate a partial break in a cable core as low as 5% of total copper core.

Surge Generators 30 Surge Generators are produced in a range from 5KV to 32KV with discharge energy ranging from 500 Joules to 3500 Joules. Combintion Systems are available that enables the user to Pre-Locate high resistance faults.

Partial Break Systems 31 A DC Current is passed through the cable core under test. The cable can be tapped with a small hammer or some mechanical beater to produce small mechanical shock waves through the cable. As the impedance changes at the fault, a small AC signal is produced. This signal is conditioned and amplified to an audible level.

Cable Route Tracers

Cable route tracers are required when buried cables need to be traced. Our systems can trace “Live” cables, which has electrical current flowing through it or “Dead” cables or pipes, by inducing the necessary current into them. Depth determination is simple and accurate.

Cable Locators 32 Adret Test Equipment supplies a range of Cable Route Tracing instruments. Our systems are reliable and easy to use. Depth of the traced object is displayed in a digital manner.

Page 6: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

6

Ove

rvie

w

ADRET GROUP

Custom Made Test Vans and Mobile Labs

Due to the sensitivity of expensive test equipment it is preferred to permanently mount these units in a trailer or panel van. The equipment can thus be protected from mechanical shock. Various Cable Reel systems are available. Our systems utilize our unique magnetic brake system.

Cable Reel Systems 33 The Adret range of Cable Reel Systems are pro-duced in single reel, 3 reel of any combinations. Our Anti-Overrun system uses powerful Rare Earth magnets to prevent the reels from over-running when unwound.

Test Equipment Trolleys 37 The range is complimented with our custom made trolleys.

Test Vans 38 Due to the diversity of test equipment used by our base of customers we produce a number of custom made test van layouts. Customers are not stuck with existing designs.

Mobile Test Trailers 39 Some customers prefer Test Trailers when they have access problems into buildings, or when dedicated vehicles are not available.

Mobile Test Laboratories 40 We are capable of retrofitting any existing test equipment of any type, with or without on- board power supplies.

Page 7: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

7

Ove

rvie

w

ADRET GROUP

Proof and Diagnostic Test Instruments

We produce various different models of Electrical Proof Test Equipment. AC, DC and VLF Systems are available for any voltage up to 200KV.

AC Systems 41 Alternating Current Proof Testers are used to test busbars, switchgear, transformers and a large array of different objects for electrical integrity.

DC Systems 42 Direct Current Proof Testers are used to test certain cable types, for example, Paper Insulat-ed Lead Cables. It is generally used where large capacitive loads are to be tested.

AC/DC Systems 43 Combination systems are produced with the Test Engineer in mind that has to perform differ-ent tests in different electrical environments. Some units simply switch between AC/DC and in some cases it is simple as fitting a diode to the circuit.

VLF Systems 47 Very Low Frequency Systems are used to test special cable types, for example, XLPE, where DC Systems may damage the solid composite insulation of the cable.

Tan Delta and Off-Line Partial 53 Discharge Systems Tan Delta and Partial discharge testing can be per-formed at VLF Frequencies. Sophisticated equipment

is available to test cables before they go into ser-vice

Page 8: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

8

Ove

rvie

w

ADRET GROUP

Bucket Liner Testers

High Voltage line maintenance crews need to be safely insulated from earth. Insulat-ed Cherry Pickers use an Insulated Bucket Liner inside the bucket that need to be test-ed for electrical insulation integrity. We supply a range of systems custom designed to do the job.

Bucket Liner Testers 54 Bucket Liners are used to test the insulation integrity of insulated “Cherry Picker” bucket liners. The systems can also be used to perform any other tests where voltages up to 300kV may be required.

Oil Dielectric Testers 55 Oil Dielectric Testers are used to test the insula-tion properties of insulating oil. Systems of up to 100kV are available.

Oil Dielectric Testers

Transformer and switchgear insulating oil has to be tested on a regular basis for the ingress of water and other impurities. Our range of Oil Dielectric testers are designed to test oil to a range of internationally pre-determined, pre-programmed test se-quences.

Test Equipment Rentals

Adret Test Equipment rents out test equipment for use when customers prefer to do their own testing. We have a full range of units available for extended periods.

Rentals 56 Full range available for rental

Page 9: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

9

Ove

rvie

w

ADRET GROUP

Inverter Mains Power Systems 57 The Adret range of inverters was developed to solve the problem of the unregulated nature of power sup-plied by Generators. Due to the nature and sensitivity of electronic equipment, needing a stable supply, failures can be minimized to a great extent.

Page 10: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

10

Ove

rvie

w

ADRET GROUP

Safety Systems

We offer a range of safety devices for the electrical test industry. Cable identification and Cable Spiking Systems are an integral part of the safe test environment.

Cable Identification Systems 59 The Adret range of Cable Identification systems are designed to positively identify any chosen cable from a bundle.

Cable Spiking Systems 61 The Adret Cable Spiking Gun is used to spike an identified cable to ensure there is no power present before work commences.

Phasing Sticks 62 We supply a range of Phasing Sticks used to ensure there is no high voltage present before any work is done. The system can also be used to “Phase” cables before they are connected into ring systems.

High Voltage Discharge Rods 63 Adret Manufactures a range of High Voltage Discharge Rods, used to safely discharge capaci-tive energy stored in cables after testing.

Arc-Flash Suits 65 We supply a range of Arc-Flash suits used when electrical switching is to be safely preformed.

Page 11: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

11

Ove

rvie

w

ADRET GROUP

Plymouth Tapes

The Adret Group represents Plymouth Rubber Europa as the sole distributor of their High Quality Insulation tapes and associated products. Plymouth Rubber is based in Spain with development and production facilities in Spain and the United states of America.

Mining Tapes 67 Due to the extreme conditions found in the mining industry, a very special type of insulation material is required to be used in this hazardous environment. Plymouth has the product for you.

Electrical Tapes 68 Plymouth produces a range of electrical insula-tion tapes used as the basic insulation material in Power Cable Joints. Different products are available to replace different insulation materi-als of the cable to be repaired.

Telecommunication Tapes 69 A range of telecommunication products are produced by Plymouth, providing all the need-ed insulation materials required by this indus-try.

Automotive Tapes 70 The Automotive industry requires a unique line of products which can offer solutions for the difficult conditions found in motor vehicles and trucks.

Page 12: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

12

Ove

rvie

w

ADRET GROUP

New Macey Electrical Connectors

New Macey Africa produce a large range of Bolted couplers for mining, military, ma-rine and defence applications. The mining plugs and sockets are produced to the highest standards and are totally resistant to water ingress.

Mining Plugs and Sockets 70 New Macey Africa manufactures a range of wa-terproof electrical connectors, from multi-pin low voltage communications and lighting plugs to 22 kV 800 amp high voltage connectors. These are all corrosion free, robust and fully waterproof. Our objective is to supply a com-plete solution to a customer’s problem, not just a box of components.

Page 13: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

13

Po

we

r P

rod

uct

s ADRET GROUP

SG7505

Surg

e G

en

era

tor

SG7

50

5

Surge Generators Electricity supply or distribution companies often find that buried power cables become faulty due to ageing or damage. Because energy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages.

The instrument described on this pamphlet gen-erates voltages selectable between 3 or 5 KV and is typically used in the location of faults in low voltage networks such as street lighting or smaller consumers. The maximum storage ener-gy of the capacitor is 500 J at 3KV and 750 J at 5KV. All surge generators generate high voltag-es from the mains supply voltage, which is recti-fied and used to charge capacitors, which is in turn discharged into a faulty cable at adjustable intervals. The unit has an internal automatic dump contactor which discharges both the unit and the cable under test. This is activated when the unit is turned off or when power failure occurs. It can be operated in the single shot or continuous pulsing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output levels.

Specifications Supply Voltage 220-240VAC

Supply Current 10A

Output Voltage 3 or 5kV Surge energy 500 Joules at 3kV

750 Joules at 5kV Weight 40kg Dimensions 540x315x330mm Excluding lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Electro

statically powder coated

Voltage level adjustment Switched between 3 or 5kV Meters 1 only voltage Indication Proof Testing Yes

PCA Interface Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 Core

Page 14: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

14

Po

we

r P

rod

uct

s ADRET GROUP

SG50016

Surg

e G

en

era

tor

SG5

00

16

Surge Generator Supply Voltage 220-240VAC

Supply Current 10A

Output Voltage 2.5-16kV Surge energy 500 at 4, 8 and

16kV Weight 45kg Dimensions 540x315x330mm Excluding lid Impulse Rate 6 or 10 PPM Enclosure Aluminium, Electro

statically powder coated

Voltage level adjustment Switched between 2.5, 4, 5, 8, 10,

16kV

Meters Voltage Indication

and Leakage cur-rent Indication

Proof Testing Yes with Leakage current indication

PCA Interface Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m Green/yellow Mains Lead 2m 3 core

Electricity supply or distribution companies often find that buried power cables become faulty due to ageing or damage. Because energy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the location of faults in power cable networks. They come in a variety of models from low voltage to very high voltages. The instrument described on this pamphlet generates voltages ranging from 2.5 to 16kV

and is typically used in the location of faults in medium voltage networks. The maximum storage energy of the capacitor is 500 J at 4,8 and 16kV. All surge generators gener-ate high voltages from the mains supply voltage, which is rectified and used to charge capacitors, which is in turn dis-charged into a faulty cable at adjustable intervals. The unit has an internal automatic dump contactor which discharges both the unit and the cable under test. This is acti-vated when the unit is turned off or when power failure occur. It can be operated in the single shot or continuous pulsing meth-od if correct selection is made. The unit can also be used to perform insulation re-sistance tests up to the selected output lev-els.

Page 15: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

15

Po

we

r P

rod

uct

s ADRET GROUP

SG130032

Surg

e G

en

era

tor

SG1

30

03

2

Surge Generators Electricity supply or distribution companies often find that buried power cables become faulty due to ageing and damage. Because en-ergy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages.

The instrument described on this pamphlet generates voltages adjustable from 0 to 32kV and is typically used in the location of faults in medium voltage networks. The maximum stor-age energy of the capacitor is 1300 J at 8,16 or 32kV. All surge generators generate high voltag-es from the mains supply voltage, which is recti-fied and used to charge capacitors, which is in turn discharged into a faulty cable at adjustable intervals. The unit has an internal automatic dump contactor which discharges both the unit and the cable under test. This is activated when the unit is turned off or when power failure occur. It can be operated in the single shot or continuous pulsing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output levels.

Surge Generator Supply Voltage 220-240VAC

Supply Current 15A Output Voltage 0-32kV Surge energy 1300 Joules at 8,

16, 32kV Weight 80kg Dimensions 540x420x400mm Excluding lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously adjustable Meters Voltage and Current Proof Testing Yes

PCA Interface Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core

Page 16: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

16

Po

we

r P

rod

uct

s ADRET GROUP

SG200032

Surg

e G

en

era

tor

SG2

00

03

2

Surge Generators Electricity supply or distribution companies often find that buried power cables become faulty due to historic damage. Because energy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages.

The instrument described on this pamphlet generates voltages selectable from 0 to 32kV and is typically used in the location of faults in medium voltage networks. The maximum stor-age energy of the capacitor is 2000 J at 8,16 or 32kV. All surge generators generate high volt-ages from the mains supply voltage, which is rectified and used to charge capacitors, which is in turn discharged into a faulty cable at adjusta-ble intervals. The unit is automatically made safe when it is turned off or when power failure occurs. It can be operated in the single shot or continuous pulsing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output levels.

Specifications Supply Voltage 220-240VAC

Supply Current 15A Output Voltage 0-32kV Output energy 2000 Joules Max Weight 80kg Dimensions 540x420x400mm Excluding lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously Adjustable Meters Voltage and Current Proof Testing Yes PCA Interface Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m Green/Yellow Mains Lead 2m 3 core

Page 17: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

17

Po

we

r P

rod

uct

s ADRET GROUP

Buffalo 5

Surg

e G

en

era

tor

Bu

ffal

o 5

Buffalo 5 System Electricity supply or distribution companies often find that buried power cables become faulty due to ageing or damage. Because ener-gy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. The Buffalo 5 unit is used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. The Buffalo 5 unit is mainly used for the location of faults in power cable networks. They come in a variety of models from low voltage to very high voltages. The instrument described on this pamphlet generates voltages selectable between 3 or 5 KV

and is typically used in the location of faults in low voltage networks such as street lighting or smaller consumers. The maximum storage en-ergy of the capacitor is 500 J at 3KV and 750 J at 5KV. All Buffalo 5 units generate high voltages from the mains supply voltage, which is rectified and used to charge capacitors, which is in turn discharged into a faulty cable at adjustable in-tervals. The unit has an internal automatic dump contactor which, upon power failure or turn off, discharges both the unit and the cable under test. This is activated when the unit is turned off or when power failure occurs. It can be operated in the single shot or continuous pulsing method if correct selection is made. The unit can also be used to perform DC insulation resistance tests up to the selected output levels. Our very successful Arc-Echo method is added to this unit and forms part of the system.

Buffalo Unit Supply Voltage 220-240VAC

Supply Current 10A Output Voltage 3 or 5kV Surge energy 500 Joules at 3kV

750 Joules at 5kV Weight 60kg Dimensions 600x470x310mm Excluding lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Switched between 3 or 5kV Meters 1 only voltage Indication Proof Testing Yes PCA Interface Built in

Arc-Echo Interface Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m Green/Yellow Mains Lead 2m 3 core

Page 18: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

18

Po

we

r P

rod

uct

s ADRET GROUP

Buffalo 16

Surg

e G

en

era

tor

Bu

ffal

o 1

6

Buffalo 16 System Electricity supply or distribution companies often find that buried power cables become faulty due to ageing or damage. Because ener-gy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages. The instrument described on this pamphlet generates voltages selectable between 2.5 - 16

KV and is typically used in the location of faults in low voltage networks such as street lighting or smaller consumers. The maximum storage energy of the capacitor is 500 J at 16kV. All surge generators generate high voltages from the mains supply voltage, which is rectified and used to charge capacitors, which is in turn dis-charged into a faulty cable at adjustable inter-vals. The unit has an internal automatic dump contactor which discharges both the unit and the cable under test. This is activated when the unit is turned off or when power failure occurs. It can be operated in the single shot or continu-ous pulsing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output lev-els. Our very successful Arc-Echo method is added to this unit and forms part of the frame-work.

Surge Generator Supply Voltage 220-240VAC

Inverter: Battery (optional) Supply Current 10A Output Voltage 4, 8 or 16 kV Surge energy 500 Joules at

16kV Weight 60kg Dimensions 564x466x383mm Excluding lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Switched be-tween

4, 8 or 16kV Metering 1 only voltage

Indication Proof Testing Yes PCA Interface Built in Arc-Echo Interface Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core

Page 19: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

19

Po

we

r P

rod

uct

s ADRET GROUP

Buffalo 130032

Surg

e G

en

era

tor

Bu

ffal

o 1

30

03

2

Buffalo 32 System Electricity supply or distribution companies often find that buried power cables become faulty due to ageing or damage. Because ener-gy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages.

The instrument described on this pamphlet generates voltages selectable between 3-32 KV and is typically used in the location of faults in low voltage networks such as street lighting or smaller consumers. The maximum storage energy of the capacitor is 1300 J at 8, 16 and 32kV. All surge generators generate high volt-ages from the mains supply voltage, which is rectified and used to charge capacitors, which is in turn discharged into a faulty cable at adjusta-ble intervals. The unit has an internal auto-matic dump contactor which discharges both the unit and the cable under test. This is acti-vated when the unit is turned off or when pow-er failure occurs. It can be operated in the sin-gle shot or continuous pulsing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output levels. Our very successful Arc-

Surge Generator Supply Voltage 220-240VAC

Supply Current 16A Output Voltage 0-32kV Surge energy 1300 Joules at

8, 16, 32kV Weight 120kg Dimensions 950x540 x540mm Including lid Impulse Rate 6 or 20 PPM Enclosure Aluminium,

Electro statically powder coated

Voltage level adjustment Continuously adjustable Meters Voltage and Current Proof Testing Yes Scope and Coupling Unit Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core Trolley Optional extra

Page 20: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

20

Po

we

r P

rod

uct

s ADRET GROUP

Buffalo 200032

Surg

e G

en

era

tor

Bu

ffal

o 2

00

03

2

Buffalo 32 System Electricity supply or distribution companies often find that buried power cables become faulty due to ageing or damage. Because ener-gy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages. The instrument de-scribed on this pamphlet generates voltages selectable between 3-32 KV and is typically used in the location of faults in low voltage

networks such as street lighting or smaller con-sumers. The maximum storage energy of the capacitor is 2000 J at 8, 16 and 32kV. All surge generators generate high voltages from the mains supply voltage, which is rectified and used to charge capacitors, which is in turn dis-charged into a faulty cable at adjustable inter-vals. The unit has an internal automatic dump contactor which discharges both the unit and the cable under test. This is activated when the unit is turned off or when power failure occurs. It can be operated in the single shot or continuous pulsing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output levels. Our very successful Arc-Echo method is added to this unit and forms part of the framework.

Surge Generator Supply Voltage 220-240VAC

Supply Current 16A Output Voltage 0-32kV Surge energy 2000 Joules at 8,

16, 32kV Weight 120kg Dimensions 950x540x540mm Including lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously adjustable Meters Voltage and Current Proof Testing Yes Scope and Coupling Unit Built in

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core Trolley Optional extra

Page 21: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

21

Po

we

r P

rod

uct

s ADRET GROUP

GMA205

Gro

un

d M

icro

ph

on

e G

MA

20

5

General Description

The GMA205 Seismophone was originally de-veloped to cater for the needs of cable fault location technicians where simplicity of use and high accuracy is of utmost importance in noisy environments. The instrument is equipped with a sharp cutoff noise cancelling filter, which greatly simplifies the acoustic pinpoint location of faults. It is also equipped with a number of other user-friendly features to simplify the procedure. Display of infor-mation is done in analog meter fashion.

Principles of Operation

The instrument embodies the very latest Ana-log Electronic techniques. The acoustic amplifi-er employs high class analog filters to filter as much noise as possible before the signal is amplified. The magnetic amplifier is gain ad-justable which allows the operator to attenu-ate the magnetic signal and then pinpoint ex-actly where the cable is.

Filters

Filter 150 – 700 Hz

Display

Two 100uA FSD Analogue meters

Acoustic Amplifier

Gain: Better than 120 dB

Acoustic Indication Low Impedance Headphones (4 Ohms)

Dimensions

200 x 110 x 90mm

Weight

1.1 kg. (Including Batteries)

Power supply

2 x Duracell Plus C 9V. Accessible from the side panel.

Battery life: Approximately 20 hours

Page 22: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

22

Po

we

r P

rod

uct

s ADRET GROUP

GMA305

Gro

un

d M

icro

ph

on

e G

MA

30

5

General Description

The GMA305 Seismophone was originally devel-oped to cater for the needs of cable fault loca-tion technicians where simplicity of use and high accuracy is of utmost importance in noisy environments. The instrument is equipped with a number of filters, which greatly simpli-fies the acoustic pinpoint location of faults. It is also equipped with a number of other user-friendly features to simplify the procedure. Display of information is done in bar graph fashion.

Principles of Operation

The instrument embodies the very latest DSP (Digital Signal Processing) techniques, which greatly broadens the possibilities to upgrade and modify the instrument by simply updating

the software. This means that whenever new technology is developed it will become availa-ble to you as the owner of the instrument. The acoustic amplifier employs five different filters to filter as much noise as possible before the signal is amplified. The magnetic amplifier is gain adjustable which allows the operator to attenuate the magnetic signal and then pin-point exactly where the cable is. It also em-ploys distance measurement techniques, which measure the time difference between the acoustic and magnetic amplifier. The display is of a 128 x 64 graphical LCD display. Automatic Magnetic Gain Adjustment feature – The instru-ment is set up in Auto Magnetic Gain mode by “memorizing” the cable depth. Auto power shut down feature - Instrument shuts down after 5 min of no user interaction. Backlight also switches off after 30 seconds, if no user interac-tion.

Filters

Filter A: 50 – 1000 Hz

B: 150 – 700 Hz

C: 150 – 1000 Hz

D: 300 – 2000 Hz

E: 700 – 3600 Hz

Distance Measurement

Range 1: 0 – 4 m

2: 0 – 20 m

3: 0 – 60 m

4: 0 – 410 m

Display

128x64 Graphical LCD display with backlight. The magnitudes of the signal peaks are indicat-ed with a bar graph which gets cleared after 2

seconds. A line marker is then left behind to continuously indicate the signal peak’s magni-tude until it is reset upon the arrival of a new signal peak. Acoustic Amplifier

Gain: Better than 120 dB

Acoustic Indication Low Impedance Headphones (4 Ohms) Dimensions

200 x 110 x 90mm

Weight

1.4 kg. (Including Batteries)

Power supply

2x 9 V - PP3 batteries. Accessible from the side panel.

Battery life: Approximately 10 hours of con-tinuous operation.

Page 23: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

23

Po

we

r P

rod

uct

s ADRET GROUP

PCA100

Po

we

r C

able

An

alyz

er

PC

A1

00

Power Cable Analyzer The Adret PCA100 was developed to assist power and communication cable fault location technicians in pre-locating and pre-determining distances to faults existing in power cables. It gives a direct reading in meters to the fault distance. It is capable of locating low resistance (that is any fault lower than about 120 ohms or infinity ohms). Operating Modes TDR In the TDR (Time domain Reflectometer) mode the instrument transmits a pulse which is re-flected off the far end of the cable. Any imped-

ance mismatches (i.e. Joints, open or short circuits) along the cable are also reflected. The waveforms are easy to analyze. Features

Locates faults quickly and easily Automatically places cursors Automatically selects range Built in Backlight Rechargeable Batteries Simple keyboard

Specifications Range 0-8km Resolution 1m(0-125m), 2m(125-

250m), 4m(250-500m), 8m(500m-1km), 16m(1km-2km), 32m(2km-4km), 64m(4km-8km)

Pulse Amplitude 30V Pulse Width 80ns-5us Dead Zone 1m Velocity Adjust 100-300m/us Gain 0-80db Display 128*64 Lattice LCD Power Supply NiMH Batteries Dimension 225*105*50mm Weight 420gr

Standard Accessories

Padded canvas carry case All necessary cables Switch mode battery charger and power

supply Operator manual

Page 24: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

24

Po

we

r P

rod

uct

s ADRET GROUP

PCA101

Po

we

r C

able

An

alyz

er

PC

a10

1

Power Cable Analyzer The Adret PCA101 was developed to assist power cable fault location technicians in pre-locating and pre-determining distances to faults existing in power cables. It gives a direct reading in meters to the fault distance. Fault distances can also be determined from the far end of the cable by simply moving two cursors to any two points on the display screen. It is capable of locating low resistance (that is any fault lower than about 120 ohms or infinity ohms) or high resistance faults with the help of any standard impulse generator and the Adret AE101 high voltage coupling unit.

Operating Modes The unit is capable of pre-locating distance to fault in three distinct modes.

TDR In the TDR (Time domain Reflectometer) mode the instrument transmits a pulse which is re-flected off the far end of the cable. Any imped-ance mismatches (i.e. Joints, open or short circuits) along the cable are also reflected. The waveforms are easy to analyze.

Impulse Current In the Impulse Current Mode a high voltage discharge generated by a surge generator is applied to a faulty cable until the fault breaks down. Thus, the surge energy is then reflected back to its source. Upon arriving at the source it is reflected back into the cable. This contin-ues until the energy is depleted. The PCA101 will capture and store the current waveform flowing in the cable and display it for analysis.

ARC-Echo In the ARC-Echo mode the instrument is con-nected to the faulty cable via the AE101 Cou-pling unit. This unit provides the suitable isola-tion and filtering required to superimpose a TDR waveform on top of the high voltage surge generated by the surge generator. When the high voltage energy arrives at the fault it tem-porarily breaks it down causing a short term short circuit. The waveforms are simple and easy to analyze and look exactly like TDR wave-forms.

Specifications Weight 3Kg Size 300 x 300 x 130 mm Controls Watertight front panel with

integrated multi-function tactile membrane switches

Power source Rechargeable NiMH battery pack (charger with standard accessories)

Battery life Approximately 4 hours for continuous use

Display 240 x 320 Pixel Transmissive LCD with multi-level grey-scaling (permanently back-lit)

Enclosure Scratch resistant PVC enclo-sure with lifetime guaran-tee.

Standard Accessories

Padded canvas carry case All necessary cables Switch mode battery charger and power

supply Operator manual

Page 25: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

25

Po

we

r P

rod

uct

s ADRET GROUP

PCA201

Po

we

r C

able

An

alyz

er

PC

A2

01

Power Cable Analyzer The Adret PCA201 was developed to assist power cable fault location technicians in pre-locating and pre-determining distances to faults existing in power cables. It gives a direct reading in meters or feet to the fault position. Fault distances can also be deter-mined from the far end of the cable by simply moving two cursors to any two points on the display screen. It is capable of locating low resistance (that is any fault lower than about 120 ohms or infinity ohms) or high resistance faults with the help of any standard impulse generator and the Adret AE101 high voltage coupling unit.

Operating Modes The unit is capable of pre-locating distance to fault in three distinct modes. The unit features an automatic mode in all ranges where the cable length, gain level and fault positions are indicated by the press of only a few buttons. In addition to this there is also the Expert Mode where all settings can be set by hand.

TDR In the TDR (Time domain Reflectometer) mode the instrument transmits a pulse which is reflected off

the far end of the cable. Any impedance mismatches (i.e. Joints, open or short circuits) along the cable are also reflected. The waveforms are easy to analyze.

Impulse Current In the Impulse Current Mode a high voltage discharge generated by a surge generator is applied to a faulty cable until the fault breaks down. Thus the surge energy is then reflected back to its source. Upon arriving at the source it is reflected back into the cable. This continues until the energy is depleted. The PCA201 will capture and store the current wave-form flowing in the cable and display it for analysis.

ARC-Echo In the ARC-Echo mode the instrument is connected to the faulty cable via the AE101 Coupling unit. This unit provides the suitable isolation and filtering re-quired to superimpose a TDR waveform on top of the high voltage surge generated by the surge generator. When the high voltage energy arrives at the fault it temporarily breaks it down causing a short term short circuit. The waveforms are simple and easy to analyze and look exactly like TDR waveforms.

Specifications Weight 6Kg Size 450 x 300 x 200 mm Controls Watertight front panel with Touch Display Power source Mains – 240v Display 12” VGA Full Color Touch Screen with Stylus Enclosure Scratch resistant PVC enclosure with lifetime guarantee. Operating System Windows 7 Waveform Storage Windows Capabilities Limited to HDD space (250GB) Printer All Windows driven printers. Keyboard Windows Virtual Keyboard

Page 26: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

26

Po

we

r P

rod

uct

s ADRET GROUP

AE101

Co

up

ling

Un

it A

E10

1 High Voltage Coupling Unit

Pre-Locating distances to cable faults are not always as simple as connecting a TDR (Time domain Reflectometer) unit to the cable under test. When the fault resistance is higher than 120 ohms the fault can simply not be detected by any TDR. The AE101 and PCA101 combina-tion was developed to fill the gap that exists above 120 ohms to well within the Meg ohm range. It will easily detect and display infor-mation which can be analyzed by anyone with TDR waveform analyzing skills.

Principles of Operation The AE101 is connected in series with any standard surge generator and faulty cable

which provides the high voltage energy needed to temporarily break down high resistance cable faults. When flashover occurs at the fault the AE101 will limit the current flowing and allow the arc to burn for a slightly longer peri-od. The AE101 allows the PCA101 to be cou-pled through suitable filters to the high voltage high energy pulse. Because burning arcs are always a low resistance, we can now use TDR techniques. A single TDR pulse is superim-posed on top of the HT pulse at the correct time. When the pulse arrives at the burning low resistance arc a short circuit is reflected to the TDR. The waveforms are then simply treated and analyzed as any other TDR wave-form when a short circuit is detected.

Coupling Unit Operating Voltage Max 32kV DC

Weight 20kg Dimensions 350x200x300mm Excluding lid Enclosure Aluminium, Elec-

tro statically pow-der coated

Pulse Withstand Rate 5 PPM Coupling Capacitor 100nF Coupling Resistor 300R

Accessories Lid Aluminium with canvas bag for test cables Test cables 2m HT Interconnection lead

with high current connect-or

Earth Lead 5m yellow/green

Page 27: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

27

Po

we

r P

rod

uct

s ADRET GROUP

SFL16T

She

ath

Fau

lt L

oca

tor

SFL1

6T

Sheath Fault Locator Trans-mitter The SFL16T is developed to test for damages on cable sheaths. The Adret SFL16T instrument is designed with simplicity of use and maxi-mum operator safety in mind.

Principles of Operation Sheath Fault Locators are mainly used to pin-point pinholes and damages to cable sheaths. The instrument generates a constant DC volt-

age that leaks into the ground and causes a “Pool of Potential” around the area of leakage. The leakage can then be pinpointed by using the SFL16R and two earth spikes. The instrument is automatically made safe when it is turned off and when a power failure occurs. It can be operated in the continuous or pulsing method. The instrument can also be used to perform pressure tests up to 16 kV DC

Specifications

Supply voltage 220-240V AC

Output voltage 0-16kV @ 150mA continuously adjustable by variable trans former.

Weight 35 kg.

Dimensions 446X343X387mm

Excluding Lid

Country of Origin South Africa

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core

Page 28: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

28

Po

we

r P

rod

uct

s ADRET GROUP

SFL16R

She

ath

Fau

lt L

oca

tor

SFL1

6R

Sheath Fault Locator Receiver It will receive leakage currents generated by the SFL16T at a constant or pulsed DC voltage that leaks into the ground and causes a “Pool of Potential” using the two ground spikes. The instrument can be synchronized to the SFL16T pulse, and generates an audible signal when synchronized to the SFL16T.

The signals come in bursts of three with a resting period in between. The potential difference between the two earth spikes will be amplified and displayed via the galvometer on the front panel. The meter indicates the relative position of the fault rela-tive to the two spikes.

Specifications

Supply voltage 9V Battery

Weight 500gr

Dimensions 200X200X80mm

Standard Accessories

Padded canvas carry case All necessary cables Switch mode battery charger and power supply Operator manual Locating Earth Spikes with carrybag

Page 29: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

29

Po

we

r P

rod

uct

s ADRET GROUP

BU3500

Cab

le F

ault

Co

nd

itio

nin

g U

nit

BU

35

00

Cable fault conditioning unit Cable fault conditioning units or “Burndown Units” are used when the resistance of cable faults is too high for Time Domain Reflectome-ter’s to show a reflection. TDR`s can only show a reflection under two conditions. The fault resistance has to be be-low 120R, or infinity. Thus, a method had to be devised to break down the resistance of faults to within the 120R level.

Principles of Operation Burndown transformers use a tapped trans-former system capable of producing high volt-

age low current at the one end of the scale and low voltage high current at the other end of the scale. The high voltage is generated through a trans-former and rectified to give a maximum output of 14kV DC at around 250mA. The low end of the scale is 50V AC at around 70A. The unit is used in a sequential manner where the current flow is monitored before a decision is made to go to a higher or lower scale.

Burndown unit Supply voltage 230V AC Supply current 15A Output: 14000V DC 250mA 8500V DC 411mA 3000V AC 1.16A 1500V AC 2.33A 1000V AC 3.5A 230V AC 15.5A 50V AC 70A Current indication Primary current Output selection Manually

switched Weight 45kg Size 400x400x500mm

Accessories Lid Aluminium with canvas Bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core

Page 30: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

30

Min

ing

Pro

du

cts

ADRET GROUP

SG100034

Surg

e G

en

era

tor

SG1

00

03

4

Surge Generators Electricity supply or distribution companies often find that buried power cables become faulty due to ageing and damage. Because energy cables are normally not supplied in lengths much longer than 300m, inevitably many joints are installed and buried. They are often the cause for cable faults which render the cable useless until repaired and put back into service. Surge generators are used in conjunction with pre-location and pinpoint location equipment to precisely locate the position of cable faults. Surge generators are mainly used for the loca-tion of faults in power cable networks. They come in a variety of models from low voltage to very high voltages.

The instrument described on this pamphlet generates voltages adjustable from 0 to 32kV and is typically used in the location of faults in medium voltage networks. The maximum storage energy of the capacitor is 1000 J at 8.5, 17 or 34kV. All surge generators generate high voltages from the mains supply voltage, which is rectified and used to charge capaci-tors, which is in turn discharged into a faulty cable at adjustable intervals. The unit has an internal automatic dump contactor which discharges both the unit and the cable under test. This is activated when the unit is turned off or when power failure occur. It can be operated in the single shot or continuous puls-ing method if correct selection is made. The unit can also be used to perform insulation resistance tests up to the selected output levels.

Specifications Supply Voltage 220-240VAC

Supply Current 15A Output Voltage 0-34kV Surge energy 1000 Joules at

8.5, 17, 34kV Weight 80kg Dimensions 540x420 x400mm Excluding lid Impulse Rate 6 or 20 PPM Enclosure Aluminium, Elec-

trostatically powder coated

Voltage level adjustment Continuously adjustable Meters Voltage and Current Proof Testing Yes, Current

limiting via resis-tors. Leakage current dis-played through viewing window.

PCA Interface Built in

Accessories Lid Aluminium with canvas bag for test ca bles Test cables 5m HT lead with high cuurent clamps Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core

Page 31: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

31

Min

ing

Pro

du

cts

ADRET GROUP

PB201

Min

ing

Fau

lt L

oca

tio

n S

yste

m P

B2

01

Partial Break Tester The Adret PB201 was developed to assist trail-ing power cable fault location technicians in pre-locating and pre-determining position of partial faults existing in trailing power cables. It gives an audible indication where the fault is located by the pitch of the sound changing on the headphones. Some external cable beating device is required to make the unit operate. It is capable of locating partial breaks in cable strands to as low as 5% of strands broken.

Operating Modes The unit is capable of simultaneously energiz-ing two individual circuits in a specific cable.

Operating Principles The unit works by simply passing a DC current through a suitable coupling transformer in series with the cores of the cable under test. When the beater approaches a fault, the re-sistance of the fault changes due to the me-chanical movement in the core. This minute change in resistance is then sampled and am-plified to produce the necessary signals.

Specifications Weight 8Kg Size 300 x 300 x 300 mm Controls Watertight front panel

with integrated multi-function tactile membrane switches

Power source Mains Charging any 12V Lead Acid Battery

Battery life Approximately 4 hours for continuous use with 65AH Battery

Enclosure Pelican Case

Standard Accessories

Padded canvas carry case All necessary cables Operator manual

Page 32: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

32

Cab

le R

ou

te T

race

rs

ADRET GROUP

AP-1

Cab

le L

oca

tors

AP

-1

Cable & Pipe Locator The AP-1 is a new high performance digital instrument for locating the alignment and depth of buried cables and pipes. The instru-ment is easy to use and gets the job done with accurate and consistent results.

Principles of Operation The unit uses the magnetic signal detected, flowing in the cable. This signal exists in live cables and in dead cables, a suitable signal is induced either via direct connection or by using various induction techniques.

Features High Accuracy up to 2.5% Triple depth detection up to 12m Maximum 10W signal output Dual Frequency transmission Automatic impedance matching 4 Antenna design Differential coils reduces interference Depth reference in Radio and Power Mode Current measurement display with depth Integrated backlight Error protection function

Cable & Pipe Locator

Transmitter Output Frequencies 38, 9.5, 80kHz

512, 640Hz

Output Power 10W Operating Modes Direct Inductive External Coil Battery 10pcs Type D Battery Life >20hrs Battery Status Low Battery Press Key Read Visual Indication LCD Bar graph

and Digital with

Backlight Operating Temperature -20 - +50C

Receiver Active Frequencies 38, 9.5, 80kHz

512, 640Hz

Depth Range 12m Accuracy +- 2,5% Battery 6pcs Type AA Battery Life >20hrs Adjustment Auto/Manual Signal Display Compasses Battery, Light Sound etc Operating Temperature -20 - +50C

Page 33: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

33

Mo

bile

Sys

tem

s ADRET GROUP

CRS30-A

Cab

le R

ee

l Sys

tem

CR

S30

-3

Test Cable Reel Systems Cable fault finding equipment often gets fitted inside dedicated test trailers or trucks. When this is the case the test cable are nor-mally at least 30m long and a neat and protec-tive storage system is required. Our system consists of 3 reels capable of wind-ing 30m of HT test cable, 30m of 2.5mm x 3 core mains cable and 30m of 10mm earth cable with connections every 2m for easy con-

nection to the earthing system. All three reels use a unique Adret adjustable brake system to control slack when the cable is unwound. Cables are unwound and rewound manually.

Cable Reel System Mains Cable 30m 3 Core 2.5mm Rub-

ber insulated HT Cable 30m Adret Specification

10mm 70kV HT Test Cable Earth Cable 30m 10mm Earth Cable

with easy connection to earth system every 2m

Slack Control Slack is controlled

through unique magnetic clutch system

Weight Approximately

30kg when fully wound up

Height 500mm Construction materials Electro statically

powder coated aluminium with steel frame

Page 34: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

34

Mo

bile

Sys

tem

s ADRET GROUP

CRS30-3

Cab

le R

ee

l Sys

tem

CR

S30

-3

Test Cable Reel Systems Cable fault finding equipment often gets fitted inside dedicated test trailers or trucks. When this is the case the test cables is normal-ly at least 30m long and a neat and protective storage system is required. Our system consists of 3 reels capable of wind-ing 30m of HT test cable, 30m of 2.5mm x 3 core mains cable and 30m of 10mm earth cable with connections every 2m for easy con-

nection to the earthing system. All three reels use a unique Adret adjustable brake system to control slack when the cable is unwound. Cables are unwound and rewound manually.

Cable Reel System Mains Cable 30m 3 Core 2.5mm Rub-

ber insulated HT Cable 30m Adret Specification

10mm 70kV HT Test Cable Earth Cable 30m 10mm Earth Cable

with easy connection to earth system every 2m

Slack Control Slack is controlled

through unique magnetic clutch system

Weight Approximately

80kg when fully wound up

Height 1400mm Construction materials Electro statically

powder coated aluminium with steel frame

Page 35: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

35

Mo

bile

Sys

tem

s ADRET GROUP

CRS30-A

Cab

le R

ee

l Sys

tem

CR

S30

-3

Test Cable Reel Systems Cable fault finding equipment often gets fitted inside dedicated test trailers or trucks. When this is the case the test cables is normal-ly at least 30m long and a neat and protective storage system is required. Our system consists of 3 reels capable of wind-ing 30m of HT test cable, 30m of 2.5mm x 3 core mains cable and 30m of 10mm earth cable with connections every 2m for easy con-

nection to the earthing system. All three reels use a unique Adret adjustable brake system to control slack when the cable is unwound. Cables are unwound and rewound manually.

Cable Reel System Mains Cable 30m 3 Core 2.5mm Rub-

ber insulated HT Cable 30m Adret Specification

10mm 70kV HT Test Cable Earth Cable 30m 10mm Earth Cable

with easy connection to earth system every 2m

Slack Control Slack is controlled

through unique magnetic clutch system

Weight Approximately

40kg when fully wound up

Height 600mm Construction materials Electro statically

powder coated aluminium with steel frame

Page 36: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

36

Mo

bile

Sys

tem

s ADRET GROUP

CRS50-3

Cab

le R

ee

l Sys

tem

CR

S30

-3

Test Cable Reel Systems Cable fault finding equipment often gets fitted inside dedicated test trailers or trucks. When this is the case the test cable is normally at least 30m long and a neat and protective storage system is required. Our system consists of 3 reels capable of wind-ing 50m of HT test cable, 50m of 2.5mm x 3 core mains cable and 50m of 10mm earth cable with connections every 2m for easy con-

nection to the earthing system. All three reels use a unique Adret adjustable brake system to control slack when the cable is unwound. Cables are unwound and rewound manually.

Cable Reel System Mains Cable 50m 3 Core 2.5mm Rub-

ber insulated HT Cable 50m Adret Specification

10mm 70kV HT Test Cable Earth Cable 50m 10mm Earth Cable

with easy connection to earth system every 2m

Slack Control Slack is controlled

through unique magnetic clutch system

Weight Approximately

80kg when fully wound up

Height 1500mm Construction materials Electro statically

powder coated aluminium with steel frame

Page 37: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

37

Mo

bile

Sys

tem

s ADRET GROUP

Custom Trolleys

Test

Eq

uip

me

nt

Tro

lleys

Specifications A wide range of different trolleys can be supplied, ranging from the smallest to the largest units available in the test industry. Frames are made of electrostatically powder coated steel and wheels are of the pneumatic type. All units are custom made to customer specifications.

Page 38: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

38

Mo

bile

Sys

tem

s ADRET GROUP

Custom Test Vans

Test

Van

s

Specifications A wide range of different test Vans can be supplied, ranging from the smallest to the largest units available in the test industry. Frames are made of electrostatically powder coated steel and wheels are of the pneumatic type. All units are custom made to customer specifications.

Page 39: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

39

Mo

bile

Sys

tem

s ADRET GROUP

Custom Test Trailers

Test

Tra

ilers

Specifications A wide range of different trailers can be supplied, ranging from the smallest to the largest units available in the test industry. Frames are made of electrostatically powder coated steel and wheels are of the pneumatic type. We supply trailers, but we also retrofit existing equipment in existing trailers. All units are custom made to customer specifications.

Page 40: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

40

Mo

bile

Sys

tem

s ADRET GROUP

Mobile Test Labs

Mo

bile

Te

st L

abs

Specifications A wide range of different Mobile Laboratories can be supplied, ranging from the smallest to the largest units available in the test industry. Frames are made of electrostatically powder coated steel and wheels are of the pneumatic type. We supply test vans, but we also retrofit existing equipment into existing vans. All units are custom made to customer specifications.

Page 41: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

41

Pro

of

Testi

ng

ADRET GROUP

3010PT

AC

Sys

tem

s 3

01

0P

T

Proof test equipment Test engineers and technicians need to proof-test cables and switchgear after installation or rework to existing systems. The Adret range of proof testers was designed with simplicity of use and maximum operator safety in mind. The range offers many differ-ent models from DC to AC and VLF (very low frequency) as well as combination AC and DC models.

Principles of Operation All the units use the input voltage through a

step up transformer to obtain the high AC volt-ages. In case of DC output the AC is rectified through a suitable rectifier capable of with-standing the high voltages. Some units use a combination of AC and DC that is switched to deliver AC or DC or both. In the case of VLF equipment a pseudo sine wave is produced through a number of switches and resistors. The outputs are current limited and the unit automatically trips when a set limit is reached. When this occurs the cable is discharged and made safe through a built in discharge resistor. In case the circuit layout does not allow (in case of split units) the automatic discharge of the cable, a suitable manual discharge resistor is supplied

Proof tester Supply Voltage 220-240VAC

Supply Current 8A Output Voltage 0-30kV AC Output Current 10mA Continu-ous Weight 40kg Dimensions 420x280 x400mm Excluding lid Enclosure Aluminium,

Electro statically powder coated

Voltage level adjustment Continuously variable

Meters Voltage and Current Trip level 0-50mA (Factory

Pre-set)

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m yellow/green Mains Lead 2m 3 core

Page 42: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

42

Pro

of

Testi

ng

ADRET GROUP

2510PT

DC

Sys

tem

s

25

10P

T

Proof test equipment Test engineers and technicians need to proof-test cables and switchgear after installation or rework to existing systems. The Adret range of proof testers was designed with simplicity of use and maximum operator safety in mind. The range offers many different models from DC to AC and VLF (very low fre-quency) as well as combination AC and DC models.

Principles of Operation All the units use the input voltage through a step up transformer to obtain the high AC volt-ages. In case of DC output the AC is rectified

through a suitable rectifier capable of with-standing the high voltages. Some units use a combination of AC and DC that is switched to deliver AC or DC or both. In the case of VLF equipment a pseudo sine wave is produced through a number of switches and resistors. The outputs are current limited and the unit automatically trips when a set limit is reached. When this occurs the cable is discharged and made safe through a built in discharge resistor. In case the circuit layout does not allow (in case of split units) the automatic discharge of the cable, a suitable manual discharge resistor is supplied The units are portable and simple to operate. Tests are possible to most well used ISO stand-ards

Proof tester Supply Voltage 220-240VAC

12V internal

battery

Supply Current 5A

Output Voltage 0-25kV DC Output Current 10mA Continuous Weight 30kg Dimensions B 240mmx L

400mmx H 450mm

Excluding lid Enclosure Aluminium, Elec-

tro statically

powder coated Voltage level adjustment Continuously

variable Meters Voltage and Current Trip level 50mA

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m yellow/green Mains Lead 2m 3 core

Page 43: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

43

Pro

of

Testi

ng

ADRET GROUP

3042PT

AC

/DC

Sys

tem

s 3

04

2P

T

Proof test equipment Test engineers and technicians need to proof-test cables and switchgear after instal-lation or rework to existing systems. The Adret range of proof testers was de-signed with simplicity of use and maximum operator safety in mind. The range offers many different models from DC to AC and VLF (very low frequency) as well as combi-nation AC and DC models.

Principles of Operation All the units use the input voltage through a step up transformer to obtain the high AC voltages. In case of DC output the AC is rectified through a suitable rectifier capable of withstanding the high voltages.

Some units use a combination of AC and DC that is switched to deliver AC or DC or both. In the case of VLF equipment a pseu-do sine wave is produced through a number of switches and resistors. The outputs are current limited and the unit automatically trips when a set limit is reached. When this occurs the cable is dis-charged and made safe through a built in discharge resistor. In case the circuit layout does not allow (in case of split units) the automatic discharge of the cable, a suitable manual discharge resistor is supplied The units are portable and simple to oper-ate. Tests are possible to most well used ISO specifications.

Proof tester Supply Voltage 220-240VAC

Supply Current 8A Output Voltage 0-30kVAC

0-42kVDC Output Current 10mA Continu-ous Weight 40kg Dimensions 420x280x400mm Excluding lid Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously variable

Meters Voltage and Current Trip level 0-50mA Factory

Pre-set

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m yellow/green Mains Lead 2m 3 core

Page 44: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

44

Pro

of

Testi

ng

ADRET GROUP

5010PT

AC

/DC

Sys

tem

s 5

01

0P

T

Proof test equipment Test engineers and technicians need to proof-test cables and switchgear after instal-lation or rework to existing systems. The Adret range of proof testers was de-signed with simplicity of use and maximum operator safety in mind. The range offers many different models from DC to AC and VLF (very low frequency) as well as combi-nation AC and DC models.

Principles of Operation All the units use the input voltage through a step up transformer to obtain the high AC voltages. In case of DC output the AC is rectified through a suitable rectifier capable of withstanding the high voltages.

Some units use a combination of AC and DC that is switched to deliver AC or DC or both. In the case of VLF equipment a pseu-do sine wave is produced through a number of switches and resistors. The outputs are current limited and the unit automatically trips when a set limit is reached. When this occurs the cable is dis-charged and made safe through a built in discharge resistor. In case the circuit layout does not allow (in case of split units) the automatic discharge of the cable, a suitable manual discharge resistor is supplied The units are portable and simple to oper-ate. Tests are possible to most well used ISO specifications.

Proof tester Supply Voltage 220-240VAC

Supply Current 10A Output Voltage 0-35kVAC 0-50kVDC Output Current 50mA Continu-ous Weight 30kg and 20kg Dimensions 350x200x300mm Control Unit

350x200x300mm HT Unit Excluding lid Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously variable

Meters Voltage and Current Trip level 10mA

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m yellow/green Mains Lead 2m 3 core Discharge Stick Included 5m interconnection cable Rectifier diode Current limiting resistor Corona ring

Page 45: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

45

Pro

of

Testi

ng

ADRET GROUP

7010PT

AC

/DC

Sys

tem

s 7

01

0P

T

Proof test equipment Test engineers and technicians need to proof-test cables and switchgear after instal-lation or rework to existing systems. The Adret range of proof testers was de-signed with simplicity of use and maximum operator safety in mind. The range offers many different models from DC to AC and VLF (very low frequency) as well as combi-nation AC and DC models.

Principles of Operation All the units use the input voltage through a step up transformer to obtain the high AC voltages. In case of DC output the AC is rectified through a suitable rectifier capable of withstanding the high voltages.

Some units use a combination of AC and DC that is switched to deliver AC or DC or both. In the case of VLF equipment a pseu-do sine wave is produced through a number of switches and resistors. The outputs are current limited and the unit automatically trips when a set limit is reached. When this occurs the cable is dis-charged and made safe through a built in discharge resistor. In case the circuit layout does not allow (in case of split units) the automatic discharge of the cable, a suitable manual discharge resistor is supplied The units are portable and simple to oper-ate. Tests are possible to most well used ISO specifications.

Proof tester Supply Voltage 220-240VAC

Supply Current 10A Output Voltage 0-50kVAC 0-70kVDC Output Current 50mA Continu-ous Weight 30kg and 20kg Dimensions 350x200x300mm Control Unit

350x200x300mm HT Unit Excluding lid Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously variable

Meters Voltage and Current Trip level 10mA

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m green/yellow Mains Lead 2m 3 core Discharge Stick Included 5m interconnection cable Rectifier diode Current limiting resistor Corona ring

Page 46: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

46

Pro

of

Testi

ng

ADRET GROUP

10010PT

AC

/DC

Sys

tem

s 1

00

10

PT Proof test equipment

Test engineers and technicians need to proof-test cables and switchgear after instal-lation or rework to existing systems. The Adret range of proof testers was de-signed with simplicity of use and maximum operator safety in mind. The range offers many different models from DC to AC and VLF (very low frequency) as well as combi-nation AC and DC models.

Principles of Operation All the units use the input voltage through a step up transformer to obtain the high AC voltages. In case of DC output the AC is rectified through a suitable rectifier capable of withstanding the high voltages.

Some units use a combination of AC and DC that is switched to deliver AC or DC or both. In the case of VLF equipment a pseu-do sine wave is produced through a number of switches and resistors. The outputs are current limited and the unit automatically trips when a set limit is reached. When this occurs the cable is dis-charged and made safe through a built in discharge resistor. In case the circuit layout does not allow (in case of split units) the automatic discharge of the cable, a suitable manual discharge resistor is supplied The units are portable and simple to oper-ate. Tests are possible to most well used ISO specifications.

Proof tester Supply Voltage 220-240VAC

Supply Current 10A Output Voltage 0-70kVAC 0-100kVDC Output Current 50mA Continu-ous Weight 30kg and 30kg Dimensions 350x200x300mm Control Unit

380x300x500mm HT Unit Excluding lid Enclosure Aluminium, Elec-

tro statically pow-der coated

Voltage level adjustment Continuously variable

Meters Voltage and Current Trip level 10mA

Accessories Lid Aluminium with canvas bag for test cables Test cables 5m HT lead with high Current clamps Earth Lead 5m yellow/green Mains Lead 2m 3 core Discharge Stick Included 5m interconnection cable Rectifier diode Current limiting resistor Corona ring

Page 47: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

47

Pro

of

Testi

ng

ADRET GROUP

VLF-28CMF

Ve

ry L

ow

Fre

qu

ency

Sys

tem

s

Very Low Frequency Testers VLF test sets are used to field test high capacitance loads like cables and motors/generators. The lower the frequency of an AC source, the lower the current and power required to apply a volt-age to a capacitive load like a cable. At 0.1Hz, it requires 500 times less power to test a cable than at 50Hz. The HVI VLF instruments permit users to field testlong cables and large generators with a portable and affordable test set. A 100 lb VLF instrument can do the job of a multi-ton 50Hz AC test set. Cables should be tested with AC voltage. With the HVI VLF products, it can be down with a practical, economical, and easy to use package.

Specifications Input Voltage: 230V 50Hz, 3A Peak 2A Average Output: 0-28kV Peak, 0.1Hz Sinusodial Duty Cycle: Continuous Load Rating: 0.4uF Metering: Voltage –30 - 0 - +30 kVAC Current 0-50mA Peak HV Output Cable: Shielded EPR Cable 6m Size: 381X292X559mm Weight: 34kG

Page 48: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

48

Pro

of

Testi

ng

ADRET GROUP

VLF-4022CMF

Ve

ry L

ow

Fre

qu

ency

Sys

tem

s

Very Low Frequency Testers VLF test sets are used to field test high capacitance loads like cable and motors/generators. The lower the frequency of an AC source, the lower the current and power required to apply a volt-age to a capacitive load like a cable. At 0.1Hz, it requires 500 times less power to test a cable than at 50Hz. The HVI VLF instruments permit users to field test long cables and large generators with a portable and affordable test set. A 100 lb VLF instrument can do the job of a multi-ton 50Hz AC test set. Cables should be tested with AC voltage. With the HVI VLF products, it can be done with a practical, economical, and easy to use package.

Specifications Input Voltage: 230V 50Hz, 6A Peak, 2.5A Average Output: 0-44kV Peak, 0.1/0.05/0.02Hz Sinusodial Duty Cycle: Continuous Load Rating: 1.1uF @ 0,1Hz, 2.2uF @ 0.05Hz, 5.5uF @ 0.02Hz Metering: Voltage –45 - 0 - +45 kVAC, Current 0-100mA Peak, Capacitance 0-6uF HV Output Cable: Shielded RG/8U Cable 6m Size: Control Unit 559X286X387, HV Tank 368X267X483mm Weight: Control Unit 23kG HV Tank 33Kg

Page 49: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

49

Pro

of

Testi

ng

ADRET GROUP

VLF-6022CMF

Ve

ry L

ow

Fre

qu

ency

Sys

tem

s

Very Low Frequency Testers VLF test sets are used to field test high capacitance loads like cables and motors/generators. The lower the frequency of an AC source, the lower the current and power required to apply a volt-age to a capacitive load like a cable. At 0.1Hz, it requires 500 times less power to test a cable than at 50Hz. The HVI VLF instruments permit users to field test long cables and large generators with a portable and affordable test set. A 100 lb VLF instrument can do the job of a multi-ton 50Hz AC test set. Cables should be tested with AC voltage. With the HVI VLF products, it can be down with a practical, economical, and easy to use package.

Specifications Input Voltage: 230V 50Hz, 8A Peak, 4A Average Output: 0-62kV Peak, 0.1/0.05/0.02Hz Sinusodial Duty Cycle: Continuous Load Rating: 1.1uF @ 0,1Hz, 2.2uF @ 0.05Hz, 5.5uF @ 0.02Hz Metering: Voltage 65kVAC, Current 0-100mA Peak, Capacitance 0-6uF HV Output Cable: Shielded EPR Cable 6m Size: Control Unit 660X330X406, HV Tank 381X260X546mm Weight: Control Unit 34kG HV Tank 54Kg

Page 50: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

50

Pro

of

Testi

ng

ADRET GROUP

VLF-90CMF

Ve

ry L

ow

Fre

qu

ency

Sys

tem

s

Very Low Frequency Testers VLF test sets are used to field test high capacitance loads like cables and motors/generators. The lower the frequency of an AC source, the lower the current and power required to apply a volt-age to a capacitive load like a cable. At 0.1Hz, it requires 500 times less power to test a cable than at 50Hz. The HVI VLF instruments permit users to field test long cables and large generators with a portable and affordable test set. A 100 lb VLF instrument can do the job of a multi-ton 50Hz AC test set. Cables should be tested with AC voltage. With the HVI VLF products, it can be down with a practical, economical, and easy to use package.

Specifications Input Voltage: 230V 50Hz, 20A Peak, 15A Average Output: 0-90kV Peak, 0.1/0.05/0.02Hz Sinusodial Duty Cycle: Continuous Load Rating: 0.55uF @ 0,1Hz, 1.1uF @ 0.05Hz, 2.75uF @ 0.02Hz Metering: Voltage 100kVAC, Current 0-100mA Peak, Capacitance 0-6uF HV Output Cable: Shielded EPR Cable 6m Size: Control Unit 660X330X406, HV Tank 381X533X737mm Weight: Control Unit 34kG HV Tank 133Kg

Page 51: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

51

Pro

of

Testi

ng

ADRET GROUP

VLF-12011CMF

Ve

ry L

ow

Fre

qu

ency

Sys

tem

s

Very Low Frequency Testers VLF test sets are used to field test high capacitance loads like cable and motors/generators. The lower the frequency of an AC source, the lower the current and power required to apply a volt-age to a capacitive load like a cable. At 0.1Hz, it requires 500 times less power to test a cable than at 50Hz. The HVI VLF instruments permit users to field test long cables and large generators with a portable and affordable test set. A 100 lb VLF instrument can do the job of a multi-ton 50Hz AC test set. Cables should be tested with AC voltage. With the HVI VLF products, it can be down with a practical, economical, and easy to use package.

Specifications Input Voltage: 230V 50Hz, 30A Peak, 25A Average Output: 0-120kV Peak, 0.1/0.05/0.02/0.01Hz Sinusodial Duty Cycle: Continuous Load Rating: 0.55uF @ 0,1Hz, 1.1uF @ 0.05Hz, 2.75uF @ 0.02Hz,[email protected] Metering: Voltage 120kVAC, Current 0-100mA Peak, Capacitance 0-6uF HV Output Cable: Shielded Shielded EPR Cable 30m Size: Control Unit 432X280X241mm, HV Tank 660X508X686mm Weight: Control Unit 9kG HV Tank 177Kg

Page 52: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

52

Pro

of

Testi

ng

ADRET GROUP

VLF-200CMF

Ve

ry L

ow

Fre

qu

ency

Sys

tem

s

Very Low Frequency Testers VLF test sets are used to field test high capacitance loads like cables and motors/generators. The lower the frequency of an AC source, the lower the current and power required to apply a volt-age to a capacitive load like a cable. At 0.1Hz, it requires 500 times less power to test a cable than at 50Hz. The HVI VLF instruments permit users to field test long cables and large generators with a portable and affordable test set. A 100 lb VLF instrument can do the job of a multi-ton 50Hz AC test set. Cables should be tested with AC voltage. With the HVI VLF products, it can be down with a practical, economical, and easy to use package.

Specifications Input Voltage: 230V 50Hz, 80A Peak Output: 0-200kV Peak, 0.1/0.05/0.02/0.01Hz Sinusodial Duty Cycle: Continuous Load Rating: 0.75uF @ 0,1Hz, 1.5uF @ 0.05Hz, 3.75uF @ 0.02Hz Metering: Voltage 200kVAC, Current 0-100mA Peak, Capacitance 0-6uF HV Output Cable: No Cable, Bushing Only Size: Control Unit 610X650X1800mm, HV Tank 1550X903X2200mm Weight: Control Unit 295kG HV Tank 1678Kg

Page 53: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

53

Pro

of

Testi

ng

ADRET GROUP

VLF Tan Delta Testing

Ve

ry L

ow

Fre

qu

ency

Tan

De

lta

Tan Delta Measurement Tan Delta can be used to help determine the insulation quality of cables and other capaci-tive loads. It is used in conjunction with a Very Low Frequency (VLF) AC Power Supply to measure the loss angle or Tan Delta of the insulation. These measurements can be used to track the deterioration of service aged cable and establish baseline readings on new cable installations. Changes in Tan Delta measure-ments can indicate degradation of the insula-tion, which can be used to make engineering decisions about the service life of the cables.

The TD System is a bridge for use with a sinus-oidal high voltage VLF power supply. High volt-age is applied to the test specimen through the measuring unit. The control unit compares the phase angles of the voltage and current wave-forms to give a loss angle of the insulation.

Specifications Current Range 0 – 50 mA Frequency Range 0.01 H z – 0.2 Hz Working Volt age 1 kV – 60 kV Peak Resolution of Measurement 0.000 5 Accuracy 2% + 0.005 Zero err or Display 128 x 64 Back lit Liquid Crystal Displayed Data Loss angle (radians) System voltage (kV Peak) and frequency (Hz) Current at HV (mA RMS) Low Battery and No Data indicators Controls Averaging Mode Normal, Medium, Extended Input Power 230 V, 50/60 Hz, 70 W Dimensions and Weights Control System 343X279X127mm, 6.4 kg Measurement Bridge 254X254X813mm, 10.4 k g

Page 54: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

54

Bu

cket

Lin

er

Test

ers

ADRET GROUP

ALT-120/60F

Bu

cket

Lin

er

Test

ers

ALT-120/60 The ALT-120/60 is a portable high voltage AC test set designed to test aerial lifts. It is de-signed to meet all ANSI A92.2 testing require-ments for insulated work platforms, bucket trucks and liners. The unit may also be used to test other electrical apparatus requiring AC voltage testing. It is rugged, reliable, economi-cal, contains advanced features, and provides long term duty ratings. The ALT-120 is de-signed to provide continuously adjustable AC output up to 120 kV with a full kVA tap at 60

kV. It is rated for 7 kVA of power, enabling it to meet all testing requirements. Its generous duty rating allows the user to perform many tests sequentially or use the unit for other, extended time testing applications. Since ver-satility of test equipment is important, the duty cycle of any product should be strongly considered.

Specifications Input Voltage 230V, 30A Output Voltage 60/120kV Output Power 7 kVA Duty Cycle 1 hr. @ 7kVA and continuous duty @ 4kVA Metering 250 μA current meter range Protection Transit protecting meter circuits

Other Models Available ALT-200(F) 0 – 200kVac @ 30mA, 6 kVA, Optional 50kVac full kVA tap available ALT -300F 0 – 300kVac @ 23 mA, 7 kVA Liner Testers available. Up to 50 kVac @ 10 kVA

Page 55: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

55

Oil

Die

lect

ric

Test

ers

ADRET GROUP

Oil

Test

ers

DTS-60A The DTS-60A is a fully automatic liquid dielec-tric test set, typically used for testing the volt-age breakdown level of insulating oils. The most commonly used testing standards are preprogrammed into the controls. Just hit the start button and the test is performed. Custom test sequences can also be programmed. The

results are stored internally for downloading to a computer and/or for printing on the print-er included.

Specifications Input Voltage 230 V, 50Hz, 3 amps OutputVoltage 0 – 60 kVac, 800 VA resistive Voltage Rise Variable. 0 – 5 kV/s in .1 kV/s steps Shutdown time 4.2 ms Voltage Accuracy 0.5% Size & Weight 381X356X292mm, 29 kg Operating temp -10º C to 40º C

Features • Clear and easy to use controls • 128 x 64 dot matrix crystal display • 10 pre programmed standard test sequences ASTM D877/87, ASTM D1816/84, IEC 156/63, IEC 156/95, VDE 0370-P5/92, CEI 10-1/73, IRAM 2341/72, UTE C27-221/74, RVHP 1985, PN-77/ED4408 • Internal memory holds last 50 tests w/ RS232 interface • User definable test sequences • Ambient temperature sensor • English, German, Spanish, French, Greek • Thermal printer included

Page 56: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

56

Test

Eq

uip

me

nt

Re

nta

ls

ADRET GROUP

Rental Equipment

Test

Eq

uip

me

nt

Re

nta

ls

Offer Adret Test Equipment offer a large range of Cable Fault Location instruments for rental. Rental periods are totally flexible from as little as one day to as long as one year.

Page 57: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

57

Inve

rte

r M

ain

s Sy

ste

ms

ADRET GROUP

INV1000

Inve

rte

rs Inverter Mains System

The Adret range of inverters was developed to solve the problem of the unregulated nature of power supplied by Generators. Due to the nature and sensitivity of electronic equipment, need-ing a stable supply, failures can be minimized to a great extent. Our Inverter systems electronically generate a constant, regulated mains supply from 12VDC. Systems range from as little as 300W to 3000W of power. Our Dual Battery system ensures that the batteries are charged from the vehicle alternator, ensur-ing full batteries when the operator arrives at the work site. The system also ensures that the main vehicle battery does not discharge, preventing the engine from starting.

Specifications Inverter Inverter 1000W Constant Short Term 2000W Input Voltage 12V Output Voltage 230V, 50Hz Batteries 105AH Deep Cycle Charging System Charger Input 230V, 50Hz Charger Output 12V @ 20A Dual Battery Dual battery charging and conditioning system from vehicle alternator (Optional)

Performance The INV1000 Standard will generate enough power to drive our SG50016 for four hours

Page 58: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

58

Inve

rte

r M

ain

s Sy

ste

ms

ADRET GROUP

INV3000

Inve

rte

rs Inverter Mains System

The Adret range of inverters was developed to solve the problem of the unregulated nature of power supplied by Generators. Due to the nature and sensitivity of electronic equipment, need-ing a stable supply, failures can be minimized to a great extent. Our Inverter systems electronically generate a constant, regulated mains supply from 12VDC. Systems range from as little as 300W to 3000W of power. Our Dual Battery system ensures that the batteries are charged from the vehicle alternator, ensur-ing full batteries when the operator arrives at the work site. The system also ensures that the main vehicle battery does not discharge, preventing the engine from starting.

Specifications Inverter Inverter 3000W Constant Short Term 6000W Input Voltage 12V Output Voltage 230V, 50Hz Batteries 420AH Deep Cycle Charging System Charger 12V @ 20A From Mains Dual Battery Dual battery charging and conditioning system from vehicle alternator.

Performance The INV3000 will generate enough power to drive our SG100032 for eight hours

Page 59: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

59

Safe

ty D

evic

es

ADRET GROUP

CI75

Cab

le Id

en

tifi

cati

on

The CI75 Cable ID System Power cable jointing technicians are often faced with the problem of having to cut into existing live cables in order to expand their existing net-works. The CI75 was designed to facilitate the positive identification of one disconnected power cable from a bundle. It will, when used correctly posi-tively and safely identify one specific cable. It is very simple to operate and will give perfect re-sults time after time.

Principles of Operation The unit uses a crystal controlled sine wave as a

basis on both the transmitter and receiver of 625Hz. The signal is transmitted into the cable by directly connecting it to two of the cores on the cable to be identified. The far end of the cable should be disconnected and the same two cores short circuited. The unit will also function when the far end of the cable is put into earth using the switchgear. The signal is then picked up by the antenna and its signal strength dis-played through the analog meter on the panel. The application of the instrument is very simple and very low levels of skill is needed for success-ful positive cable identification.

Transmitter

Output Power 5W Continuous/

Pulsed Power Supply 6 X 1.5V C Cells

(Alkaline) Weight 1Kg Battery State Indication Red/Green LED Battery Life Approximately

40Hrs Operating Frequency 625Hz Range 20km Signal Pulsed or continu-

ous sine wave Output Protection Matching trans-

former isolated Operating Temperature 0C to +50C

Receiver Gain 120dB Max Filter Switched Capaci-

tor Type Power Supply 1 X 9V PP3

(Alkaline) Weight 500gr Battery State Indication Red/Green LED Battery Life Approximately

40Hrs Antenna High Gain Tuned

System Audio Indication Loudspeaker Visual Indication Analogue Panel

Meter Operating Frequency 625Hz Operating Temperature 0C to +50C

Page 60: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

60

Safe

ty D

evic

es

ADRET GROUP

CI200

Cab

le Id

en

tifi

cati

on

CI200 Cable ID System Power cable jointing technicians are often faced with the problem of having to cut into existing live cables in order to expand their existing networks. The CI200 was designed to facilitate the posi-tive identification of one disconnected power cable from a bundle. It will, when used correct-ly positively and safely identify one specific cable. It is very simple to operate and will give perfect results time after time.

Principles of Operation The CI200TX generates a DC Pulse of 50V at about 200A. The signal is transmitted into the cable by directly connecting it to one of the cores on the cable to be identified. The far end of the cable should be connected to earth. The received signal is then picked up by the flexible current clamp and its signal strength displayed through the analog meter on the panel. The application of the instrument is very simple and very low levels of skill is needed for suc-cessful positive cable identification.

Transmitter

Output Power 50V @ 200A Power Supply 230V Mains or

12V DC (Power Pack) Weight 1Kg Battery State Indication Level meter Battery Life Approx 8 Hrs Pulse Frequency 1Hz Range 20km Signal DC Pulsed Output Protection Fused Operating Temperature 0C to +50C

Receiver Power Supply 1 X 9V PP3

(Alkaline) Weight 500gr Battery State Indication Red/Green LED Battery Life Approx 8 Hrs Antenna Clamp on

Rogowski coil Visual Indication Analogue Panel

Meter Operating Temperature 0C to +50C

Page 61: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

61

Safe

ty D

evic

es

ADRET GROUP

CS-100

Cab

le S

pik

ing

Gu

n

The Cable Spiking Gun Power cable jointing technicians are often faced with the problem of having to cut into existing live cables in order to expand their existing networks. When power cables are being identified for rework, it is always necessary, after positive identification, to make sure the cable is not live. The spiking gun is a device designed with safety in mind. The instrument will ensure that the said cable is safe to work on.

Principles of Operation The unit drives a flat chisel into the cable, short circuiting all three phases together. The chisel is driven into the cable by means of a ballistic charge which is triggered remotely by the operator. The application of the instrument is very sim-ple and very low levels of skill is needed for successful safe positive cable identification. It is recommended that the cable is positively identified by means of the non-destructive Adret CI75 before use.

Specifications Maximum Cable Diamater: 100mm Minimum Cable Diameter: 50mm Accessories: Cartridges, Chisels Spare Parts: All parts available

Page 62: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

62

Safe

ty D

evic

es

ADRET GROUP

Phasing Sticks

Ph

asin

g Sti

cks

Phasing Sticks The KNES test phasing stick range has been developed and refined in conjunction with industry and mining over a number of years. There are various adapters available such as the Magnafix adapter, 500mm and 700 mm extensions, spiked tips, high voltage proving unit and Angle extensions for testing OCB’s.

All high voltage connection tips are kept well away from the operator and there is an op-tional high voltage proving unit, for additional safety, which is designed to be used before and after a test to verify the operation of the meter and neon indicator (PS/2 Model only).

SPECIFICATIONS

MODEL

Weight (Without

case)

Overall Length Range On Indicator Total Resistance Of Circuit Notes

PS2

2.3Kg

1115mm

0 – 12kV

68Mohm

Meets DIN VDE –0681/5

*

Neon Indica-tor Range = 3

– 12kV

M11E

1.8Kg

830mm

1 – 12kV

61Mohm

M1133E

3.1Kg

1300mm

0 – 12kV & 0 –

36kV

184Mohm

M33E

2.4Kg

1300mm

0 – 36kV

184Mohm

Weight of aluminum case – 5Kg

Specifications for other models on request

Page 63: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

63

Safe

ty D

evic

es

ADRET GROUP

DR306

Dis

char

ge R

od

s D

R3

06

High Voltage Discharge Rod The DR306 was designed with operator safety in mind. It is used to safely discharge high volt-age test objects to ground before it is touched by any personnel.

Principles of Operation High voltage points are discharged through a 5M Ohm or 10M Ohm resistor to earth.

DR306 Rated Voltage: 30kV Discharge Capacitance: 6uF Resistor: 5M Weight: 2.5kG Length: 700mm

Page 64: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

64

Safe

ty D

evic

es

ADRET GROUP

DR606

Dis

char

ge R

od

s D

R3

06

High Voltage Discharge Rod The DR606 was designed with operator safety in mind. It is used to safely discharge high volt-age test objects to ground before it is touched by any personnel.

Principles of Operation High voltage points are discharged through a 5M Ohm or 10M Ohm resistor to earth.

DR606 Rated Voltage: 60kV Discharge Capacitance: 6uF Resistor: 10M Weight: 2.7kG Length: 1000mm

Page 65: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

65

Safe

ty D

evic

es

ADRET GROUP

Arc-Flash Suits

Arc

-Fla

sh S

uit

s

Arc-Flash Suits ARC FLASH SUITS can increase the chances of survival and decrease the need for medical treatment (skin grafts) and the chances of subsequent infections. It can help preserve the quality of life of a worker exposed to an elec-tric arc event. PPE is not designed to be fire fighter gear, it is worn to reduce the risk of more serious injury.

Wearing ordinary clothes, especially synthetic fabrics like, nylon, in an electric arc incident may make injuries worse than if the skin was not covered at all. Normal clothes are fuel sources that ignite, burn and frequently burn into the skin.

Specifications Arc-Flash Suits are available in the following Arc Thermal Performance Values:

9+ Cal

25+ Cal 40+ Cal

90+ Cal

Page 66: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

66

Ply

mo

uth

Insu

lati

on

Tap

es

ADRET GROUP

Mining Tapes

Some of our Mining Products PLYTUFF® - F/R PVC Jacketing Tape PVC tape specifically formulated for flame resistance and abrasion resistance. Use for repairing nicks and tears in all mining cables. Use this tape for primary insulation through 600V. Ideally suited for securing premolded and shrinkable sleeve ends to the cable jack-et. Title 30-CFR 18.64, P-153-MSHA Acceptance.

GLF® Jacket Repair Wrap Use as a jacket repair or conduit repair when severe conditions tear or puncture the original cable jacket or conduit. Extremely abrasion-resistant, with excellent moisture exclusion properties. Approved under 30 CFR 7.404, approval number P-7K-SK-153082-1-MSHA.

GLF2® Jacket Repair Wrap Is our newest laminate of a specially formulated Hypalon backing and 2 flameretardant mastic layers possessing the superior abrasion and moisture resistance required for all types of cable jacket repair. The laminate is easy to apply and remains flexible at low temperatures. GLF 2 will adhere to all types of cable jackets yielding a positive moisture seal. GLF 2 with approval number P-7K-SK-153082-1-MSHA. L969 Fire-Resistant Insu-lating Tape (Linerless Rubber) Use to insulate around the connector area on splices from 600V-69kV. Also used to fill in irregularities and to smooth out the splice profile before applying jacketing tape.

Rubber Mastic (RM) Tapes A self-bonding mastic tape consisting of an ethylene propylene rubber (EPR) backing, bonded to a tacky, temperature stable, electrical grade mastic. Use for insulating and moisture sealing splices and terminations on solid dielectric cable. Can be wrapped, stretched or molded around irregular shapes for insulation buildup, water-sealing, and surface protection. Provides excellent electrical properties, superior adhesion, moisture and chemical resistance. For primary insulation up to 2kV.

Page 67: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

67

Ply

mo

uth

Insu

lati

on

Tap

es

ADRET GROUP

Electrical Tapes

Some of our Electrical Products L969 PLYVOLT Linerless High Voltage Insulating Tape A 30 mil (0,76mm) EPR , self-bonding high voltage tape for insulating and jacketing splices through 69kV. L969 Plyvolt is linerless, and permits quicker application than a tape with liner. Yields a void-free build-up. Excellent corona, ozone, and chemical resistance. L969 Plyvolt can also be used for building stress-cones on power cable through 35kV. ASTM-D-4388, HH-I-553C. W963 PLYSAFE® High Voltage Insulating Tape with Liner A 30 mil (0,76mm) EPR, self-amalgamating high voltage tape for insulating and jacketing splices through 69kV. W963 Plysafe amalgamates quickly, yielding a void-free, electrically stable build-up and is ideal for waterproofing. ASTM-D-4388, HH-I-553C/Grade A, MIL-I-3825B. 3 BI-SEAL® High Voltage Insulating Tape with Liner A polyethylene and ethylene propylene rubber based tape possessing superior electrical, chemical, mechanical and thermal properties. Fuses quickly, yielding a void-free, electri-cally stable build-up. For insulating and jacketing of splices on power cable from 600 volts through 69kV and for building stress cones and jacketing of terminations on power cable from 600 volts through 35kV. Available in 20 mil (0,51mm) or 30 mil (0,76mm) thickness. ASTM-D-4388, HH-I-553C. W962 High Voltage Insulating Tape With Liner 20 mil (0,51mm) EPR based high voltage tape with superior electrical, chemical, mechani-cal, and thermal properties. For insulating and jacketing of splices on power cable from 600 volts through 138kV and for building stress cones and jacketing of terminations on power cable from 600 volts through 35kV. W962 is self-amalgamating. ASTM-D-4388. PIB Medium Voltage Tape with Black Liner A self-amalgamating, polyisobutylene-based medium voltage tape that maintains a tight insulation build-up for void-free electrical stability and permanent resistance to moisture penetration. For insulating and jacketing of splices on power cables from 600 volts through 46kV. Plymouth’s PIB has excellent stretch capabilities that allow fast taping speeds and is compatible with all extruded dielectrical cable insulations. 17 PLYSHIELD® EPR Shielding Tape A 30 mil (0,76mm) EPR self-amalgamating, conducting tape for shielding high voltage splices and terminations. Use for rebuilding strand shield and insulation shields on high voltage splices and for shielding all types ofconnections. ASTM-D-4388. 15 PLYBRAID Tinned Copper Shielding Tape A tinned copper mesh-knit shielding with exceptional conformability for replacing metallic shield in shielded cable repair. The two-inch width allows for quicker application and a larger overlap for increased safety in flexible cables.

Page 68: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

68

Ply

mo

uth

Insu

lati

on

Tap

es

ADRET GROUP

Telecommunications Tapes

Some of our Telecommunications Products PLYCOM® T-818 (G-Vinyl) Designed specifically to meet the exacting requirements of the communications industry. T-818 is fully conformable at 0°F (-18°C) and pulls smoothly from roll at maximum splicing speeds without breaking, yet retains its strength and adhesion at elevated temperatures. Once wrapped T-818 stays down from -40°F to +176°F (-40°C to 80°C). MIL-I-24391C. “G” Vinyl Specification 8726. PLYWRAP® 11 Vinyl Corrosion Protection Tape (E-Vinyl) A strong physical barrier which is moisture-proof, inert and non-conducting. Used for protecting splice cases, load coil cases, conduit, and other areas. Provides atmospheric, galvanic, fungal, and bacterial protection. “E” vinyl Specification 8035. COHESIVE RUBBER TAPE (CR) Consists of one soft, uncured layer bonded to a cured, abrasion-resistant layer. Unique separator allows controlled removal at the user’s discretion. An air-tight, water-proof, gas-tight seal is formed when the uncured layer is bonded to itself. The industry standard for temporary splice coverings on communication and control cables. Maintains gas pressure in pressurized cable. Communications Industry Specification 7144. DOUBLE RUBBER TAPE (DR) Non-adhesive, self-bonding communications tape used for critical sealing and re-jacketing. One layer of uncured compound permanently fused to an abrasion-resistant layer of cured rubber. Easy-tear separator. Controlled unwind. Full or half-lapped, a strong bond develops between both plies to maintain gas pressure in pressurized cables. Communications Industry DR Specifications TL-192 and 6863. 150 ASTM RUBBER TAPE A 30-mil (0,76 mm) self-amalgamating, low voltage rubber tape that can be used for insu-lating cable splices through 2kV, in conjunction with a jacketing tape. Compatible with low and high density polyethylene and polypropylene PIC cables plus all rubber and PVC cable elements. 150 ASTM conforms easily and self-amalgamates into a homogenous, void-free mass to provide an effective moisture seal. ASTM-D-4388, Communications Industry Specification 6746.

Page 69: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

69

Ply

mo

uth

Insu

lati

on

Tap

es

ADRET GROUP

Automotive Tapes

Some products in the Plymouth Automotive range

N-15 PVC Harness Wrap

N-15 PVC Harness Wrap is a durable 7 mil (0,18mm) PVC wiring harnessing tape with an aggres-sive yet controlled unwind adhesive, designed to eliminate problems relating to Carpal Tunnel Syndrome during taping. Available in black, white, gray, red, yellow, brown, green and blue. Meets the specification requirements of various European car makers.

N-40 Black Splice Wrap

N-40 Black PVC Splice Wrap is a 15 mil (0,39mm) durable splice protection tape with aggressive adhesive. This tape is very puncture resistant. Meets the specification requirements of various European car makers.

#575 12 mil (0,30mm) and #579 16 mil (0,40mm) Vinyl Protective Sheets

These tapes offer superior abrasion resistance. Designed with a convenient adhesive strip on one side for easy application. #575 meets the requirements of Mazda Engineering Standard PA67015 (0,3mm), UT Automotive Spec. UTMS16003 (Type I) and Sumitomo Electric Wiring Systems SES-C3008 (03T). #579 meets the requirements of Mazda Engineering Standard PA67015, Delphi Packard Electric Spec. ESM-4043, UT Automotive Spec. UTMS 16003 (Type II) and Sumitomo Electric Wiring Systems SES-C3008 (04T).

N-60

N-60 is a 11.4 mil (0,29mm) cotton textile backed uncoated tape with a rubber-based adhesive, designed for use where wiring harness specifications require cotton fabric tape meeting 105?C requirements. Available in black, blue, yellow, brown and white. Meets the specification re-quirements of various European car makers.

Page 70: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

70

New

Mac

ey M

inin

g ADRET GROUP

Mining Plug & Receptacle

200A Plug & Receptacle

New Macey manufactures a large range of waterproof Mining Electrical plugs and receptacles. Traditionally, underground mining electrical couplers consisted of many small parts. Due to the complexity of the system these units needed replacement after only a few months. The New Macey system, made entirely of marine grade stainless steel, ensures simplicity of fitting and due to its unique construction an almost totally waterproof connection system. The unit shown above is a complete standard 200A connection system.

800A Plug & Receptacle

New Macey manufactures a large range of waterproof Mining Electrical plugs and receptacles. Traditionally, underground mining electrical couplers consisted of many small parts. Due to the complexity of the system these units needed replacement after only a few months. The New Macey system, made entirely of marine grade stainless steel, ensures simplicity of fitting and due to its unique construction an almost totally waterproof connection system. The unit shown above is a half coupler capable of 800A at 11kV. The size, weight and totally dry termination system makes this plug unique in the industry.

Page 71: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

71

New

Mac

ey R

ail

ADRET GROUP

Rail Connection system

Plate couplers

The most recent addition to our inter-car connectors is the patented range of plate couplers. These allow all power, data, communications and safety circuits to be incorporated into the one connector. Each is a separate plug or receptacle module that can be individually replaced without removing the plate coupler from a carriage. The couplers are mounted under carriage draw bars and allow sets to be separated and re joined in a matter of moments. They can operate under their design electrical loads while being fully submerged in water. New Macey plate couplers were used in the Outer Sub-urban Carriages built for Rail Corp by United Group Rail. These proved to be reliable and met the customer’s requirements for quick and safe inter-car coupling.

New Macey plugs

Plugs are securely connected to receptacles using the well tested Camlock coupling system. The two parts are separated by a rubber gasket which is compressed with coupling levers. This gives a secure and waterproof connection. Multiple terminal plugs are produced to suit your require-ments. Apart from earth and power conductors, these can include data and communications circuits.

Receptacles

New Macey receptacles use high quality silver plated multiple wire or beryllium copper lamella sockets. These significantly reduce the force required to connect to plugs and give positive con-tact along the full length of terminal pins. Allowable current densities are higher than normal solid sockets, reducing heat generation.

Page 72: Adret ompany Profile - Southern Africa Fault Location ... · PDF fileAdret ompany Profile ... (cable fault location and diagnostic testing), Surge Gen Technologies ... mine the distance

72

Contact Information Physical Address: 5 Union Street Roxton Alberton 1449 South Africa Postal Address: PO Box 1054 Alberton 1450 South Africa Tel: +27119076473 +27119074475 Fax: +27118697987 URL: www.adret.co.za Email: [email protected] [email protected] GPS Co-ordinates S 26.25098

E 28.13806