2 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 0V TST UB CES-AZ-AES-01B 104770 J SH1 O1 Read- head 1 H11 Trans- ponder H12 EUCHNER DIA 23 24 13 14 Y1 Y2 S K2 + K1 + 114 22,5 99 Safety Unit CES-AZ H11 +UB H12 0V SH1 STATE OUT DIA 13 O1 Y1 23 14 DIA Y2 24 Unicode RESET TST J S S Y 5 6 Dimension drawing Block diagram 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO con- tacts per output) Start button and feedback loop can be connected Plug-in connection terminals For possible combinations see page 24 Unicode evaluation Each actuator is unique. The evaluation unit de- tects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluation Every suitable actuator is detected by the evalu- ation unit. Guard lock monitoring Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. For suitable read heads, please refer to the combinations table on page 24. Category according to EN ISO 1849-1 Due to two redundant safety paths (relay con- tacts) with 2 internal, monitored normally open contacts per safety path, suitable for: Category 4 / PL e according to EN ISO 13849-1 Each safety path is independently safe. LED indicator STATE Status LED DIA Diagnostics LED OUT Safety output status Evaluation unit CES-AZ-AES-01B Suitable for 35 mm DIN rail according to DIN EN 50022-35 Ordering table Series Category and PL acc. to EN ISO 1849-1 Number of read heads Version Order no. / item CES-AZ-AES-01B Unicode Up to 4 / PL e 1 104770 CES-AZ-AES-01B CES-AZ-AES-01B-EX Unicode Up to 4 / PL e 1 ATEX 2) 105142 1) CES-AZ-AES-01B-EX CES-AZ-UES-01B Multicode Up to 4 / PL e 1 10519 CES-AZ-UES-01B CES-AZ-UES-01B-EX Multicode Up to 4 / PL e 1 ATEX 2) 10724 1) CES-AZ-UES-01B-EX Connection sets for evaluation unit CES-AZ-.ES-01B Plug-in screw terminals 10475 CES-EA-TC-AK04-104756 Plug-in spring terminals 1121 CES-EA-TC-KK04-112631 1) EX II (3) G [Ex nL] IIC (zone 2 gases), the evaluation unit is only allowed to be used outside potentially explosive atmospheres. Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B 1 Cat. 4 PLe Additional connections TST Input for self-test O1 Monitoring output (semiconductor) DIA Diagnostics output Y1, Y2 Feedback loop S Start button connection (monitoring of the falling edge) 1) Important: The plug-in connection terminals are not included and must be ordered sepa- rately.

Upload: others

Post on 04-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

2�

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

0V

TST

UB

CES-AZ-AES-01B

104770

J SH1

O1

Read-head1

H11

Trans-ponder

H12

EUCHNER

DIA 23 24 13 14 Y1 Y2 S

K2+

K1+

11422,5

99

Safety Unit

CES-AZ

H11

+UBH12

0V

SH1

STATE OUT DIA

13 O1 Y1 23

14 DIA Y2 24

Unicode

RESET

TST

J S

SY

56

Dimensiondrawing

Blockdiagram

1readheadcanbeconnected2safetyoutputs(relaycontactswith2internallyconnectedNOcon-tactsperoutput)StartbuttonandfeedbackloopcanbeconnectedPlug-inconnectionterminals

For possible combinations see page 24

UnicodeevaluationEach actuator is unique. The evaluation unit de-tects only the actuator that has been taught-in. Additional actuators can be taught-in.Only the last actuator taught-in is detected.New actuators are taught-in by fitting a jumper.

MulticodeevaluationEvery suitable actuator is detected by the evalu-ation unit.

GuardlockmonitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. For suitable read heads, please refer to the combinations table on page 24.

CategoryaccordingtoENISO1�849-1Due to two redundant safety paths (relay con-tacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LEDindicatorSTATE Status LEDDIA Diagnostics LEDOUT Safety output status

EvaluationunitCES-AZ-AES-01B

Suitable for 35 mm DIN railaccording to DIN EN 50022-35

Orderingtable

Series CategoryandPLacc.toENISO1�849-1 Numberofreadheads Version Orderno./item

CES-AZ-AES-01BUnicode Up to 4 / PL e 1 104770

CES-AZ-AES-01B

CES-AZ-AES-01B-EXUnicode Up to 4 / PL e 1 ATEX 2) 105142 1)

CES-AZ-AES-01B-EX

CES-AZ-UES-01BMulticode Up to 4 / PL e 1 1051�9

CES-AZ-UES-01B

CES-AZ-UES-01B-EXMulticode Up to 4 / PL e 1 ATEX 2) 10�724 1)

CES-AZ-UES-01B-EX

Connectionsetsfor evaluation unit CES-AZ-.ES-01B

Plug-inscrew terminals

10475�CES-EA-TC-AK04-104756

Plug-inspring terminals

112��1CES-EA-TC-KK04-112631

1) EX II (3) G [Ex nL] IIC (zone 2 gases), the evaluation unit is only allowed to be used outside potentially explosive atmospheres.

EvaluationunitCES-AZ-AES-01B/CES-AZ-UES-01B

1Cat.4

PLe

AdditionalconnectionsTST Input for self-testO1 Monitoring output (semiconductor)DIA Diagnostics outputY1,Y2 Feedback loopS Start button connection

(monitoring of the falling edge)

1)

Important: The plug-in connection terminals are not included and must be ordered sepa-rately.

Page 2: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

27

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

TechnicaldataevaluationunitCES-AZ-AES-01B

ParameterValue

Unitmin. typ. max.

Housing material Plastic PA6.6Dimensions 114 x 99 x 22.5 mmWeight 0.2 kgAmbient temperature at UB = DC 24 V -20 - +55 °CAtmospheric humidity, not condensing - - 80 %Degree of protection IP20Degree of contamination 2Mounting DIN rail 35 mm according to EN 50022-35Number of read heads 1 read head per evaluation unitConnection (plug-in screw terminals/coded) 0.14 - 2.5 mm²Operating voltage UB (regulated, residual ripple < 5 %) 21 24 27 V DC

For the approval according to the following applies Operation only with UL Class 2 power supply, or equivalent measures

Current consumption IB (with relay energized) 1) - 150 - mAExternal fuse (operating voltage UB) 0.25 - 8 ASafety contacts 2 (relays with internally monitored contacts)Switching current (relay outputs)

mA- At switching voltage AC/DC 21 ... 60 V 1 - 300

- At switching voltage AC/DC 5 ... 30 V 10 - 4000- At switching voltage AC 5 ... 230 V (160 V ATEX) 10 - 2000

Switching load according to Max. AC 30 V, class 2 / max. DC 60 V, class 2

External fuse (safety circuit) according to EN 60269-1 6 A gG or 6 A circuit breaker (characteristic B or C)Utilization category according to EN 60947-5-1 AC-12 60V 0.3A / DC-12 60V 0.3A

AC-12 30V 4A / DC-12 30V 4AAC-15 230V 2A / DC-13 24V 3A

- For ATEX version AC-12 60V 0.3A / DC-12 60V 0.3AAC-12 30V 4A / DC-12 30V 4AAC-15 160V 2A / DC-13 24V 3A

Classification acc. to EN 60947-5-3 PDF-MRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp 4 kVRated conditional short-circuit current 100 AResilience to vibration In acc. with EN 60947-5-2Mechanical operating cycles (relays) 10 x 106

Switching delay from state change 2) - - 210 msTime difference (between the switching points of the two relays) - - 25 msCurrent via feedback loop Y1/Y2 5 8 10 mAPermissible resistance via feedback loop - - 600 WReady delay 3) - 10 12 sDwell time 4) 3 - - sSwitching frequency max. 5) - - 0.25 HzRepeat accuracy R acc. to EN IEC 60947-5-3 ≤ 10 %Monitoring outputs (diagnostics DIA, door monitoring contact O1, semiconductor output, p-switching, short-circuit protected)- Output voltage 0.8 x UB - UB V DC- Max. load - - 20 mAStart button input S, test input TST- Input voltage LOW 0 - 2

V DC HIGH 15 - UB

- Input current HIGH 5 8 10 mAEMC protection requirements In acc. with EN 60947-5-3ReliabilityvaluesaccordingtoENISO1�849-1asafunctionoftheswitchingcurrentat24VDC ≤0.1A ≤1A ≤�ACategory 4 6)

Performance Level (PL) ePFHd 1.9 x 10-8 6)

Mission time 20 yearsNumber of switching cycles/year 760 000 153 000 34 600

1) Without taking into account the load currents on the monitoring outputs.2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 250 ms. After a brief actuation < 0.25 s, the switch-on delay can increase to max. 3 s if this is fol-lowed immediately by further actuation.3) After the operating voltage is switched on, the relay outputs are switched off and the door monitoring contact is set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.4) The dwell time is the time that the actuator must be inside or outside the operating distance.5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.6) The value may be lower depending on the read head connected. See notes for the related read head.

Page 3: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

28

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

0V

TST

UB

CES-AZ-AES-02B

104775

J1 J2 SH1

O1

Read-head1

H11

Trans-ponder

O2

H12

EUCHNER

SH2

Read-head2

H21

DIA

Trans-ponder

H22

23 24 13 14 Y1 Y2 S

K2+

K1+

45

99

114

H1H2

24Y2

O2

Y1

O1

23

STATE OUT DIA

+UB

0V

SH1

SH2

H12

H22

H11

H21

14DIA

J2

TST

J1

13

S

CES - AZSY

Safety Unit

RESET

Unicode56

12

Dimensiondrawing

Blockdiagram

2readheadscanbeconnected2safetyoutputs(relaycontactswith2internallyconnectedNOcon-tactsperoutput)StartbuttonandfeedbackloopcanbeconnectedPlug-inconnectionterminalsCat.4/PLeacc.toENISO1�849-1

For possible combinations see page 24

UnicodeevaluationEach actuator is unique. The evaluation unit de-tects only the actuator that has been taught-in. Additional actuators can be taught-in.Only the last actuator taught-in is detected.New actuators are taught-in by fitting a jumper.

MulticodeevaluationEvery suitable actuator is detected by the evalu-ation unit.

GuardlockmonitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. For suitable read heads, please refer to the combinations table on page 24.

CategoryaccordingtoENISO1�849-1Due to two redundant safety paths (relay con-tacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LEDindicatorSTATE Status LEDDIA Diagnostics LEDOUT Safety output status

EvaluationunitCES-AZ-AES-02B

Suitable for 35 mm DIN railaccording to DIN EN 50022-35

Orderingtable

Series CategoryandPLacc.toENISO1�849-1 Numberofreadheads Version Orderno./item

CES-AZ-AES-02BUnicode Up to 4 / PL e 2 104775

CES-AZ-AES-02B

CES-AZ-UES-02BMulticode Up to 4 / PL e 2 105140

CES-AZ-UES-02B

Connectionsetsfor evaluation unit CES-AZ-.ES-02B

Plug-inscrew terminals

104771CES-EA-TC-AK06-104771

Plug-inspring terminals

112��0CES-EA-TC-KK06-112630

EvaluationunitCES-AZ-AES-02B

2Cat.4

PLe

AdditionalconnectionsTST Input for self-testO1,O2 Monitoring outputs (semiconductor)DIA Diagnostics outputY1,Y2 Feedback loopS Start button connection

(monitoring of the falling edge)

Important: The plug-in connection terminals are not included and must be ordered sepa-rately.

Page 4: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

29

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

TechnicaldataevaluationunitCES-AZ-AES-02B

ParameterValue

Unitmin. typ. max.

Housing material Plastic PA6.6Dimensions 114 x 99 x 45 mmWeight 0.25 kgAmbient temperature at UB = DC 24 V -20 - +55 °CAtmospheric humidity, not condensing - - 80 %Degree of protection IP20Degree of contamination 2Mounting DIN rail 35 mm according to EN 50022-35Number of read heads Max. 2 read heads per evaluation unitConnection (plug-in screw terminals/coded) 0.14 - 2.5 mm²Operating voltage UB (regulated, residual ripple < 5 %) 21 24 27 V DCFor the approval according to the following applies Operation only with UL Class 2 power supply, or equivalent measuresCurrent consumption IB (with relay energized) 1) - 150 - mAExternal fuse (operating voltage UB) 0.4 - 8 ASafety contacts 2 (relays with internally monitored contacts)Switching current (relay outputs)

mA- At switching voltage AC/DC 21 ... 60 V 1 - 300

- At switching voltage AC/DC 5 ... 30 V 10 - 4000- At switching voltage AC 5 ... 230 V 10 - 2000

Switching load according to Max. AC 30 V, class 2 / max. DC 60 V, class 2External fuse (safety circuit) according to EN 60269-1 6 A gG or 6 A circuit breaker (characteristic B or C)Utilization category according to EN 60947-5-1 AC-12 60V 0.3A / DC-12 60V 0.3A

AC-12 30V 6A / DC-12 30V 6AAC-15 230V 2A / DC-13 24V 3A

Classification acc. to EN 60947-5-3 PDF-MRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp 4 kVRated conditional short-circuit current 100 AResilience to vibration In acc. with EN 60947-5-2Mechanical operating cycles (relays) 10 x 106

Switching delay from state change 2)

- 2 activated actuators - - 290ms

- 1 activated actuator - - 210Time difference between the switching points of the two relays (with 2 activated actuators) - - 25 ms

Manual start operating mode- Duration of operation of start button 250 - -

ms- Start button response delay - 200 300Current via feedback loop Y1/Y2 5 8 10 mAPermissible resistance via feedback loop - - 600 WReady delay 3) - 10 12 sDwell time 4) 3 - - sSwitching frequency max. 5) - - 0.25 HzRepeat accuracy R acc. to EN IEC 60947-5-3 ≤ 10 %Monitoring outputs (diagnostics DIA, release 01...02, semi-conductor output, p-switching, short circuit-protected) - Output voltage 0.8 x UB - UB V DC- Max. load - - 20 mAStart button input S, test input TST- Input voltage LOW 0 - 2

V DC HIGH 15 - UB

- Input current HIGH 5 8 10 mAEMC protection requirements In acc. with EN 60947-5-3ReliabilityvaluesaccordingtoENISO1�849-1asafunctionoftheswitchingcurrentat24VDC ≤0.1A ≤1A ≤�ACategory 4 6)

Performance Level (PL) ePFHd 1.9 x 10-8 6)

Mission time 20 yearsNumber of switching cycles/year 760 000 153 000 34 600

1) Without taking into account the load currents on the monitoring outputs.2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 430 ms. After a brief actuation < 0.4 s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation.3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.4) The dwell time is the time that the actuator must be inside or outside the operating distance.5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.6) The value may be lower depending on the read head connected. See notes for the related read head.

Page 5: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

�0

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

0V

TST

UB

CES-AZ-AES-04B

104780

J1 J2 SH1

O1

Read-head1

H11

Trans-ponder

O2

H12

EUCHNER

O3

SH2

O4

Read-head2

H21

DIA

Trans-ponder

H22

23

SH3

24

Read-head3

H31

Trans-ponder

13

H32

14

SH4

Y1

Read-head4

H41

Y2

Trans-ponder

H42

S

K2+

K1+

45

99

114

24Y2

O2

Y1

O1

23

STATE OUT DIA

+UB

0V

SH1

SH2

H12

H22

H11

H21

14DIA

J2

TST

J1

13

S

CES - AZ

H1H2H3H4SY

Safety Unit

RESET

Unicode

H31

H41

H32

H42

SH3

SH4

O3 O4

Dimensiondrawing

Blockdiagram

4readheadscanbeconnected2safetyoutputs(relaycontactswith2internallyconnectedNOcon-tactsperoutput)StartbuttonandfeedbackloopcanbeconnectedPlug-inconnectionterminalsCat.4/PLeacc.toENISO1�849-1

For possible combinations see page 24

UnicodeevaluationEach actuator is unique. The evaluation unit de-tects only the actuator that has been taught-in. Additional actuators can be taught-in.Only the last actuator taught-in is detected.New actuators are taught-in by fitting a jumper.

MulticodeevaluationEvery suitable actuator is detected by the evalu-ation unit.

GuardlockmonitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. For suitable read heads, please refer to the combinations table on page 24.

CategoryaccordingtoENISO1�849-1Due to two redundant safety paths (relay con-tacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LEDindicatorSTATE Status LEDDIA Diagnostics LEDOUT Safety output status

EvaluationunitCES-AZ-AES-04B

Suitable for 35 mm DIN railaccording to DIN EN 50022-35

Orderingtable

Series CategoryandPLacc.toENISO1�849-1 Numberofreadheads Version Orderno./item

CES-AZ-AES-04BUnicode Up to 4 / PL e 4 104780

CES-AZ-AES-04B

CES-AZ-UES-04BMulticode Up to 4 / PL e 4 105141

CES-AZ-UES-04B

Connectionsetsfor evaluation unit CES-AZ-.ES-04B

Plug-inscrew terminals

10477�CES-EA-TC-AK08-104776

Plug-inspring terminals

112�29CES-EA-TC-KK08-112629

EvaluationunitCES-AZ-AES-04B

4Cat.4

PLe

AdditionalconnectionsTST Input for self-testO1...O4 Monitoring outputs (semiconductor)DIA Diagnostics outputY1,Y2 Feedback loopS Start button connection

(monitoring of the falling edge)

Important: The plug-in connection terminals are not included and must be ordered sepa-rately.

Page 6: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

�1

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

TechnicaldataevaluationunitCES-AZ-AES-04B

ParameterValue

Unitmin. typ. max.

Housing material Plastic PA6.6

Dimensions 114 x 99 x 45 mmWeight 0.25 kgAmbient temperature at UB = DC 24 V -20 - +55 °CAtmospheric humidity, not condensing - - 80 %Degree of protection IP20Degree of contamination 2Mounting DIN rail 35 mm according to EN 50022-35Number of read heads Max. 4 read heads per evaluation unitConnection (plug-in screw terminals/coded) 0.14 - 2.5 mm²Operating voltage UB (regulated, residual ripple < 5 %) 21 24 27 V DCFor the approval according to the following applies Operation only with UL Class 2 power supply, or equivalent measuresCurrent consumption IB (with relay energized) 1) - 150 - mAExternal fuse (operating voltage UB) 0.4 - 8 ASafety contacts 2 (relays with internally monitored contacts)Switching current (relay outputs)

mA- At switching voltage AC/DC 21 ... 60 V 1 - 300- At switching voltage AC/DC 5 ... 30 V 10 - 4000- At switching voltage AC 5 ... 230 V 10 - 2000

Switching load according to Max. AC 30 V, class 2 / max. DC 60 V, class 2External fuse (safety circuit) according to EN 60269-1 6 A gG or 6 A circuit breaker (characteristic B or C)Utilization category according to EN 60947-5-1 AC-12 60V 0.3A / DC-12 60V 0.3A

AC-12 30V 6A / DC-12 30V 6AAC-15 230V 2A / DC-13 24V 3A

Classification acc. to EN 60947-5-3 PDF-MRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp 4 kVRated conditional short-circuit current 100 AResilience to vibration In acc. with EN 60947-5-2Mechanical operating cycles (relays) 10 x 106

Switching delay from state change 2)

- 4 activated actuators - - 450

ms- 3 activated actuators - - 370- 2 activated actuators - - 290- 1 activated actuator - - 210Time difference between the switching points of the two relays (with 4 activated actuators) - - 25 ms

Manual start operating mode- Duration of operation of start button 250 - -

ms- Start button response delay - 200 300Current via feedback loop Y1/Y2 5 8 10 mAPermissible resistance via feedback loop - - 600 WReady delay 3) - 10 12 sDwell time 4) 3 - - sSwitching frequency max. 5) - - 0.25 HzRepeat accuracy R acc. to EN IEC 60947-5-3 ≤ 10 %Monitoring outputs (diagnostics DIA, release 01...02, semi-conductor output, p-switching, short circuit-protected) - Output voltage 0.8 x UB - UB V DC- Max. load - - 20 mAStart button input S, test input TST- Input voltage LOW 0 - 2

V DC HIGH 15 - UB

- Input current HIGH 5 8 10 mAEMC protection requirements In acc. with EN 60947-5-3ReliabilityvaluesaccordingtoENISO1�849-1asafunctionoftheswitchingcurrentat24VDC ≤0.1A ≤1A ≤�ACategory 4 6)

Performance Level (PL) ePFHd 1.9 x 10-8 6)

Mission time 20 yearsNumber of switching cycles/year 760 000 153 000 34 600

1) Without taking into account the load currents on the monitoring outputs.2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 750 ms. After a brief actuation < 0.8 s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation.3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.4) The dwell time is the time that the actuator must be inside or outside the operating distance.5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.6) The value may be lower depending on the read head connected. See notes for the related read head.

Page 7: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

170

External Evaluation Unit CES-AR-AES

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Powersupply

UB

0V

UB UBAR

Power Out

O1

0VAR

O2

IA

Inputs

O3

IB

O4

Monitoring outputsO5

Summary ofmonitoringsignals

O6

OUTAR

O7 O8 O9

Faultsignal

DIA

O10 O11 O12

EUCHNER

Y1

Feedback loop

CES-AR-AES-12

Y2 S

StartCES

K1

K2

13

14

23

24

33

34

43

44

45

99

114

O4

O12

O3

O11

O2

O10

O1

O9

+UB

+UB

0V

S

DIA

Y2Y1

43

44

33

34

23

24

13

14

CES-AR

EUCHNERSafety Unit

O5

IA

O6

IB

O7

RESET

DIA OUT STATE

O80VAR

UBAR

OUTAR

Dimensiondrawing

Blockdiagram

CentralevaluationofanARswitchchainStatusofeachindividualswitchcanbeseenForswitchchainsofupto12devicesFourindividualsaferelaycontactsCategory4PLeacc.toENISO1�849-1

Important: For possible combinations see page 171 or 139.

FunctionThe external evaluation unit is used to evaluate the individual safety switches in a CES-AR-... switch chain and the safe interruption of a safety circuit. The unit has two inputs for connection of a CES-AR... switch chain. The safety contacts are switched as a function of the input signals. Downstream parts of the safety circuit can be monitored using a feedback loop.The switching states of the connected safety switches can be signaled by means of monitor-ing outputs.If the actuator on one of the safety switches in the switch chain is moved out of the operating distance, the external evaluation unit opens its contacts and the corresponding monitoring output is reset.The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic self-monitoring at the latest at the next demand to close the safety contacts.The system can be started either manually using a start button or automatically.

CategoryaccordingtoENISO1�849-1Due to two redundant safety paths (relay con-tacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LEDindicatorSTATE Status LED

Suitable for DIN rail according to DIN 46277 - 35 mm

Orderingtable

Series CategoryandPLacc.toENISO1�849-1/Version Orderno.

CES-AR-AES-12 4 / PL e 098225CES-AR-AES-12

Connectionsetsfor evaluation unit CES-AR-AES-12

Plug-inscrew terminals

10477�CES-EA-TC-AK08-104776

Plug-inspring terminals

112�29CES-EA-TC-KK08-112629

1) Employers' liability insurance association (DGUV) approval pending

ExternalevaluationunitCES-AR-AES-12

ExternalevaluationunitCES-AR-AES-12 Cat.4

PLe 1...12

O4

O12

O3

O11

O2

O10

O1

O9

+UB

+UB

0V

S

DIA

Y2Y1

43

44

33

34

23

24

13

14

EUCHNERSafety Unit

O5

IA

O6

IB

O7

RESET

DIA OUT STATE

O8

OUTAR

UBAR

0VAR

O4

O12

O3

O11

O2

O10

O1

O9

+UB

+UB

0V

S

DIA

Y2Y1

43

44

33

34

23

24

13

14

CES-AR

EUCHNERSafety Unit

O5

IA

O6

IB

O7

RESET

DIA OUT STATE

O80VAR

UBAR

OUTAR

CES-AR

Terminalassignment

Important: The plug-in connection terminals are not included and must be ordered sepa-rately.

DIA Diagnostics LEDOUT Safe state/self-test

1)

Page 8: Safety System CES-AZ Evaluation Units.pdf · 27 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. CES-AZ

171

External Evaluation Unit CES-AR-AES

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AR

-AES

TechnicaldataexternalevaluationunitCES-AR-AES-12

ParameterValue

Unitmin. typ. max.

Housing material Plastic PA6.6

Dimensions 114 x 99 x 22.5 mm

Weight 0.25 kg

Ambient temperature at UB = DC 24 V -15 - +55 °C

Atmospheric humidity, not condensing - - 80 %

Degree of protection according to EN 60529 IP20

Degree of contamination 2

Mounting DIN rail 35 mm according to EN 50022-35

Connection (plug-in screw terminals/coded) 0.14 - 2.5 mm²

Operating voltage UB (regulated, residual ripple < 5 %) 24 ± 10% V DC

Current consumption IB (with relay energized) 1) - 1.2 1) - A

External fuse (operating voltage UB) - 2.5 8 A gG

Safety contacts 4 (relays with internally monitored contacts)

Switching current (relay outputs)

mA- At switching voltage AC/DC 21 ... 60 V 1 - 300

- At switching voltage AC/DC 5 ... 30 V 10 - 6000

- At switching voltage AC 5 ... 230 V 10 - 5000

External fuse (safety circuit) according to EN 60269-1 6 A gG or 6 A circuit breaker (characteristic B or C)

Utilization category according to EN 60947-5-1 AC-12 60V 0.3A / DC-12 60V 0.3AAC-12 30V 6A / DC-12 30V 6AAC-15 230V 5A / DC-13 24V 5A

Classification acc. to EN 60947-5-3 PDF-M

Rated insulation voltage Ui 250 V

Rated impulse withstand voltage Uimp 4 kV

Resilience to vibration In acc. with EN 60947-5-2

Mechanical operating cycles (relays) 10 x 106

Current via feedback loop Y1/Y2 5 8 10 mA

Permissible resistance via feedback loop - - 600 WMonitoring outputs (O1 ... O12, DIA and OUT AR, semiconduc-tor outputs, p-switching, short circuit-proof)

- Output voltage 0.8 x UB - UB V DC

- Max. load - - 20 mA

- Switching frequency - 1 - Hz

Start button input S, test input TST

- Input voltage LOW 0 - 2V DC

HIGH 15 - UB

- Input current HIGH 5 8 10 mA

Safety inputs IA, IB 2 (for AR switch chain)

Number of connectable safety switches max. 12

EMC protection requirements In acc. with EN 60947-5-3

ReliabilityvaluesaccordingtoENISO1�849-1

asafunctionoftheswitchingcurrentat24VDC ≤0.1A ≤1A ≤�A

Category 4

Performance Level (PL) e

PFHd 1.5 x 10-8

Mission time 20 yearsNumber of switching cycles/year 720 000 540 000 107 000

1) Taking into account the load currents at the monitoring outputs (20 mA each)

Safetyswitch

Evaluationunit

CES-AR-AES-12

CES-AR-C01...

From V 1.1.2(see rating plate on the device)CES-AR-CR2...

CES-AR-CL2...

CET1-AR-...CET2-AR-...

From V 1.1.2(see rating plate on the device)

Whichsafetyswitchescanbeconnected?