section 00 9111...a. revision: detail 1, jeffco open school first floor plan, revise keynotes at...

89
03/03/16 15136.00 – Gym Flooring Replacement 00 9111 - 1 SECTION 00 9111 ADDENDUM NUMBER 1 PARTICULARS DATE: March 16, 2016 PROJECT: Jeffco WS&D 2016 PROJECT NUMBER: 15137.00 OWNER: Jefferson County Public Schools ARCHITECT: MOA Architecture TO: PROSPECTIVE BIDDERS 2.01 This Addendum forms a part of the Contract Documents and modifies the Bidding Documents dated March 3, 2016, with amendments and additions noted below. 2.02 Acknowledge receipt of this Addendum in the space provided in the Bid Form. Failure to do so may disqualify the Bidder. 2.03 This Addendum consists of 3 pages and the following attachments: A. Pre-Bid Meeting Attendance List. B. SECTION 00 3100 – AVAILABLE PROJECT INFORMATION. C. Sketch AD01: A1. D. Sketch AD01: A2. E. Sketch AD01: A3. F. Sketch AD01: A4. G. Sketch AD01: A5. H. Sketch AD01: A6. I. Sketch AD01: A7. SPECIFICATIONS 3.01 SECTION 00 3100 – AVAILABLE PROJECT INFORMATION: A. REPLACE: Section in its entirety with the new attached Section 00 3100. Section has been updated to include the Limited Asbestos Survey Report. 3.02 SECTION 02 4100 – DEMOLITION: A. CLARIFY: All work requiring asbestos abatement shall be performed under separate Contract through the Owner.

Upload: others

Post on 14-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

03/03/16 15136.00 – Gym Flooring Replacement 00 9111 - 1

SECTION 00 9111

ADDENDUM NUMBER 1

PARTICULARS

DATE: March 16, 2016

PROJECT: Jeffco WS&D 2016

PROJECT NUMBER: 15137.00

OWNER: Jefferson County Public Schools

ARCHITECT: MOA Architecture

TO: PROSPECTIVE BIDDERS

2.01 This Addendum forms a part of the Contract Documents and modifies the Bidding Documents dated March 3, 2016, with amendments and additions noted below.

2.02 Acknowledge receipt of this Addendum in the space provided in the Bid Form. Failure to do so may disqualify the Bidder.

2.03 This Addendum consists of 3 pages and the following attachments:

A. Pre-Bid Meeting Attendance List.

B. SECTION 00 3100 – AVAILABLE PROJECT INFORMATION.

C. Sketch AD01: A1.

D. Sketch AD01: A2.

E. Sketch AD01: A3.

F. Sketch AD01: A4.

G. Sketch AD01: A5.

H. Sketch AD01: A6.

I. Sketch AD01: A7.

SPECIFICATIONS

3.01 SECTION 00 3100 – AVAILABLE PROJECT INFORMATION:

A. REPLACE: Section in its entirety with the new attached Section 00 3100. Section has been updated to include the Limited Asbestos Survey Report.

3.02 SECTION 02 4100 – DEMOLITION:

A. CLARIFY: All work requiring asbestos abatement shall be performed under separate Contract through the Owner.

Page 2: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

03/03/16 15136.00 – Gym Flooring Replacement 00 9111 - 2

3.03 SECTION 08 7100 – DOOR HARDWARE:

A. REPLACE: Hardware Set #3, Set #9 and Set #10 in their entirety as indicated below:

SET #3 - Exst Entry - MOD1 Low Energy Operator CLD-4990 628 SD1 Power Supply 602RF x UR1 FF SE2 Actuator CL2216 630 SD2 Surface Mounting Box CL2220 SD1 Weather Ring CL2223 SD1 Elec. Strike 9600 630 HS

NOTE: Existing Door - Modify for new Auto Operator – Coordinate for requirements and Electrical

SET #9 - Exterior Mech (PR)6 Hinges FBB199 4 1/2 X 4 1/2 NRP US32D ST1 Mullion KR4954-STAB-MT54 SP28 VO1 Exit Device 98EO x 990EO 425-SNB (QTY-2) US26D VO1 Exit Device 98NL x 990NL-R&V 425-SNB (QTY-2) US26D VO1 Rim Cylinder 20-022 626 SC1 Mortise Cylinder 20-001 1 1/4" 626 SC2 Closer 4040 XP SHCUSH TBWMS ST-3596 ST-1595 AL LC2 Kick Plate KO050 - 12" x 2" LDW B4E CSK 630 TR1 Weatherstrip 700 ES TEK (HEAD & JAMBS) NA1 Mullion Seal 5100 N NA1 Drip Cap 16 A - 4” ODW NA2 Sweep | Drip 1015V x TEK NA1 Threshold 8429 x SSMS/LA - 4" ODW NOTCH AL NA

SET #10 - Exterior Storage (PR)8 Hinges FBB199 4 1/2 X 4 1/2 NRP US32D ST1 Mullion KR4954-STAB-MT54 SP28 VO1 Exit Device 98EO x 990EO 425-SNB (QTY-2) US26D VO1 Exit Device 98NL x 990NL-R&V 425-SNB (QTY-2) US26D VO1 Rim Cylinder 20-022 626 SC1 Mortise Cylinder 20-001 1 1/4" 626 SC2 Closer 4040 XP SHCUSH TBWMS ST-3596 ST-1595 AL LC2 Kick Plate KO050 - 12" x 2" LDW B4E CSK 630 TR1 Weatherstrip 700 ES TEK (HEAD & JAMBS) NA1 Mullion Seal 5100 N NA1 Drip Cap 16 A - 4” ODW NA2 Sweep | Drip 1015V x TEK NA1 Threshold 8429 x SSMS/LA - 4" ODW NOTCH AL NA

3.04 SECTION 08 4313 – ALUMINUM FRAMED STOREFRONTS:

A. REVISE paragraph 2.03, subparagraph D – Swing Doors:

REVISE item 1 to read ‘Thickness: 2 inches’ADD item 9 as follows: Subframe: Effco Model #S5900 curtain wall door adaptor with #8730 2” door stops.

B. REVISE paragraph 3.08 – Schedule of Finishes:ADD item D as follows: Witt Elementary School: Dark Bronze.

Page 3: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

03/03/16 15136.00 – Gym Flooring Replacement 00 9111 - 3

3.05 SECTION 09 2116 – GYPSUM BOARD ASSEMBLIES:

A. REVISE paragraph 2.04, subparagraph A – Finishing Accessories:

ADD: item 4 to the list of finishing accessories as follows:4. Adjustable Partition Closure: Aluminum extrusions; 6063-T5 temper, tensile strength 31 KSI per

ASTM B221, ASTM B221M.a. Basis of Design Product: Mullion Mate manufactured by Gordon Interior Specialties Division,

www.gordoninteriors.com. Size as required by detail in Drawings. 1. Substitutions: See Section 01 6000 – Product Requirements.

DRAWINGS

4.01 SHEET KEYNOTES:

A. REVISION: Revise sheet keynotes as applicable throughout Drawing Set per attached sketch AD01: A1. Keynotes have been added / revised / clarified to align with the asbestos abatement scope.

4.02 Drawing A-100 – LEAWOOD ES FLOOR PLAN:

A. REVISION: Detail 1, Leawood Elementary School Floor Plan, revise keynotes in north / northeast portion of building from 101 to 112 per attached sketch AD01: A2. ACM was not detected at these locations.

4.03 Drawing A-101 – LEAWOOD ES WINDOW ELEVATIONS AND DETAILS:

A. REVISION: Detail 10, revise detail title to read ‘LEAWOOD STOREFRONT AT EXISTING PARTITION’ Revise detail 10 per attached sketch AD01: A3. Neoprene gasket has been revised to an adjustable partition closure.

4.04 Drawing A-107 – MOORE MS ROOF PLAN:

A. REVISION: Detail 1, Moore Middle School Roof Plan, revise keynotes at each roof monitor from 101 to 112 per attached sketch AD01: A4. ACM was not detected at these locations.

4.05 Drawing A-115 – JEFFCO OPEN SCHOOL FIRST FLOOR PLAN:

A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected at these locations.

4.06 Drawing A-140 – WEBER ES FLOOR PLAN:

A. REVISION: Detail 1, Weber Elementary School Floor Plan, revise keynotes at doors F130 and F145 from 108 to 114 per attached sketch AD01: A6. ACM was not detected at these locations.

4.07 Drawing A-145 – WITT ES FLOOR PLAN:

A. REVISION: Detail 1, Weber Elementary School Floor Plan, revise keynote at door G119 from 108 to 114 and keynote at storefront ‘DA’ from 101 to 112 per attached sketch AD01: A7. ACM was not detected at these locations.

B. REVISION: Detail 2, Aluminum Frame Types. ADD notation ‘Dark Bronze Finish’ below storefront tag ‘DA’.

4.08 Drawing A-155 – LAWRENCE ES FLOOR PLAN:

A. REVISION: Door and Frame Schedule, revise door thickness for doors J101A and J101B from 1¾” thick to 2” thick.

END OF ADDENDUM NUMBER 1

Page 4: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 5: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

3/3/2016 15137.00 - Jeffco WS&D 2016 00 3100 - 1

SECTION 00 3100

AVAILABLE PROJECT INFORMATION

PART 1 GENERAL

1.01 EXISTING CONDITIONS

A. Certain information relating to existing surface and subsurface conditions and structures is available to Contractor, but are not part of the Contract Documents, as follows:

1.02 LIMITED ASBESTOS SURVEY REPORT

A. A copy of an asbestos containing material report with respect to the building is included for reference only following this section:1. Title: Limited Asbestos Survey Report.2. Date: March 1, 20163. Prepared By: Ninyo & Moore4. Phone: 303-629-6000

B. This report identifies materials containing asbestos and offers recommendations for the removal of materials prepared primarily for the use of the Owner.

C. Contractor should visit the site and become acquainted with existing conditions.

D. This report, by its nature, cannot reveal all conditions that exist on the site. Should asbestos containing material be found contact Owner and Architect immediately.

PART 2 PRODUCTS (NOT USED)

PART 3 EXECUTION (NOT USED)

END OF SECTION

Page 6: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

LIMITED ASBESTOS SURVEY REPORT

JEFFCO WARM, SAFE, & DRY 2016

JEFFCO PUBLIC SCHOOLS

PREPARED FOR:

Jeffco Public Schools

809 Quail Street, Building #4

Lakewood, Colorado 80215

PREPARED BY:

Ninyo & Moore

Geotechnical and Environmental Sciences Consultants

6001 South Willow Drive, Suite 195

Greenwood Village, Colorado 80111

March 1, 2016

Project No. 501114001

Page 7: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

March 1, 2016

Project No. 501114001

Mr. Doug Cooper

Jeffco Public Schools

809 Quail Street, Building #4

Lakewood, Colorado 80215

Subject: Limited Asbestos Survey

Jeffco Warm, Safe, & Dry 2016

Dear Mr. Cooper:

In accordance with your authorization, Ninyo & Moore has conducted a Limited Asbestos

Survey at 10 Jefferson County Schools, in support of the Jeffco Warm, Safe, and Dry 2016

project.

The attached report presents our methodology, findings, conclusions, and recommendations

regarding our survey. We appreciate the opportunity to be of service to you on this important

project.

Sincerely,

NINYO & MOORE

Mark A Williams

Senior Project Environmental Scientist

CDPHE #11552

Lise Marie Bisson, P.G.

Principal Geologist

Environmental Operations Manager

MAW/LMB

Distribution: (1) Addressee via email

Page 8: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc i

TABLE OF CONTENTS

Page

1. INTRODUCTION ....................................................................................................................1

2. PURPOSE AND SCOPE OF SERVICES ................................................................................1

3. SITE DESCRIPTION ...............................................................................................................1

4. PHYSICAL LIMITATIONS ....................................................................................................2

5. SAMPLE COLLECTION ........................................................................................................2

6. LABORATORY ANALYSES AND RESULTS .....................................................................3

7. FINDINGS AND OPINIONS ..................................................................................................3

8. RECOMMENDATIONS ..........................................................................................................4

9. LIMITATIONS .........................................................................................................................5

Table

Table 1 – Asbestos Sample Results (Leawood Elementary)

Table 2 – Asbestos Sample Results (Glennon Heights Elementary)

Table 3 – Asbestos Sample Results (Jeffco Open School)

Table 4 – Asbestos Sample Results (Slater Elementary School)

Table 5 – Asbestos Sample Results (Eiber Elementary School)

Table 6 – Asbestos Sample Results (Lumberg Elementary School)

Table 7 – Asbestos Sample Results (Weber Elementary School)

Table 8 – Asbestos Sample Results (Witt Elementary School)

Table 9 – Asbestos Sample Results (Moore Middle School)

Table 10 – Asbestos Sample Results (Campbell Elementary School)

Appendices

Appendix A Laboratory Reports and Chain-of-Custody Records

Appendix B Certifications

Page 9: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc 1

1. INTRODUCTION

In accordance with your authorization to proceed, Ninyo & Moore has conducted a Limited

Asbestos Survey (Survey) at ten Jefferson County Schools, as part of the Jeffco Warm, Safe, &

Dry 2016 Project. The Survey was limited to the areas of proposed renovation as indicated on the

design development drawings provided by JeffCo Public Schools (client). This report is based

upon site conditions at the time of the sampling activities and has been conducted in accordance

with generally accepted practices for asbestos surveys.

2. PURPOSE AND SCOPE OF SERVICES

The purpose of the Survey was to evaluate building materials for the presence of asbestos. The

objective of the Survey was to gain information regarding site conditions prior to door and/or

window replacement in the buildings. Ninyo & Moore performed the following services at each

school:

A visual reconnaissance of the readily accessible areas of the site to evaluate the possible

presence of asbestos-containing material (ACM).

The collection of building material samples related to the proposed renovation activities and

submittal to a Colorado Department of Public Health and Environment (CDPHE) registered

laboratory for analysis by polarized light microscopy (PLM). The sampling was conducted

according to EPA protocol described in the Asbestos Hazard Emergency Response Act

(Code of Federal Regulations, Section 40, Part 763). And,

Preparation of this report summarizing field activities, laboratory test results, conclusions,

and recommendations.

3. SITE DESCRIPTION

The project site included ten school buildings throughout Jefferson County. The following

schools were included in this Survey:

School Address City State

Leawood Elementary 6155 West Leawood Drive Littleton Colorado

Moore Middle 8455 West 88th Avenue Arvada Colorado

Page 10: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc 2

Glennon Heights Elementary 11025 West Glennon Drive Lakewood Colorado

Jeffco Open 7655 West 10th Avenue Lakewood Colorado

Slater Elementary 8605 West 23rd Avenue Lakewood Colorado

Eiber Elementary 1385 Independence Street Lakewood Colorado

Lumberg Elementary 6705 West 23rd Avenue Edgewater Colorado

Weber Elementary 8725 West 81st Place Arvada Colorado

Witt Elementary 10255 West 104th Avenue Westminster Colorado

Campbell Elementary 6500 Oak Street Arvada Colorado

4. PHYSICAL LIMITATIONS

No physical limitations, such as locked rooms or fenced areas, were encountered during the

Survey. However, samples were collected from the reasonably accessible areas of each building.

The insulating material of fire doors was not assessed, nor were the non-glass panels in the door

or window systems. There is a possibility that during building renovation or demolition

activities, additional ACM may be encountered in areas that were not assessed during this Survey

(e.g. interstitial wall spaces). Suspect materials encountered during renovation that have not been

assessed may either be assumed to contain asbestos, or tested for the asbestos content.

5. SAMPLE COLLECTION

On February 9 through February 19, 2016, Mr. Mark A. Williams and Mr. Robert Neumann,

CDPHE-certified asbestos building inspectors with Ninyo & Moore, conducted the Survey. The

Survey was conducted in accordance with the Colorado Air Quality Control Commission’s

Regulation 8, Part B (Regulation 8) and the United States Environmental Protection Agency

(USEPA) guidelines, within the limitations of our scope of work.

A preliminary visual assessment of suspect ACM was conducted and homogeneous areas

(areas in which the materials appear uniform in color, texture, construction or application

date, and general appearance) were identified. Each homogeneous area was observed for

material type, location, condition, and friability. Representative samples were collected from

each homogeneous material, within the limitations of the survey, using EPA-recommended

sampling procedures. Building materials sampled and analyzed for the presence of asbestos

are summarized in Tables 1-10.

Page 11: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc 3

6. LABORATORY ANALYSES AND RESULTS

A total of 107 samples of suspect ACM were collected and submitted to EMC Laboratories

(EMC) of Phoenix, Arizona for analysis. EMC is a CDPHE-registered asbestos laboratory and is

accredited by the National Voluntary Laboratory Accreditation Program (NVLAP No. 101926-0)

for bulk asbestos fiber analysis. The samples were analyzed using polarized light microscopy

with dispersion staining (PLM/Ds), for the presence and quantification of asbestos fibers, in

general accordance with EPA Method 600/R-93/116.

The lower limit of detection for asbestos using the PLM method is approximately 1%. Materials

containing asbestos, but in amounts less than 1% are defined as containing “trace” amounts. In

accordance with Regulation 8, Part B, Section III any friable material reported by PLM analysis

to contain trace asbestos must be confirmed by point count analysis.

Copies of the laboratory analytical reports and chain-of-custody records are presented in

Appendix A. A copy of Ninyo & Moore personnel and the analytical laboratory certifications are

presented in Appendix B.

7. FINDINGS AND OPINIONS

The findings of this Survey are based on our visual observations and analysis of suspect building

materials for the presence of asbestos. Based on the analytical results of bulk samples collected

during this survey, the following building materials contain asbestos in amounts greater than 1%:

Leawood Elementary

Approximately 10 square feet (SF) of friable window glazing (gray) is located on the north,

west and south windows and contains 15% chrysotile asbestos. The material was observed to

be damaged.

Moore Middle

No asbestos was detected in the materials sampled at this school.

Glennon Heights Elementary

Approximately 50 SF of non-friable caulk (light gray) is located on the door frames and con-

tains 8% chrysotile asbestos. The material was observed to be in good condition.

Page 12: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc 4

Jeffco Open Elementary

Approximately 20 SF of non-friable caulk (black/tan) is located on the door frames and con-

tains 3% chrysotile asbestos. The material was observed to be in good condition.

Slater Elementary

Approximately 30 SF of non-friable caulk (blue/beige) is located on the door frames and

contains 7% chrysotile asbestos. The material was observed to be in good condition.

Eiber Elementary

Approximately 40 SF of non-friable caulk (beige) is located on the door frames and contains

10% chrysotile asbestos. The material was observed to be in good condition.

Lumberg Elemenetary

Approximately 20 SF of non-friable caulk (yellow/gray/blue) is located on the door frames

and contains 5% chrysotile asbestos. The material was observed to be in good condition.

Approximately 20 SF of non-friable caulk (white/green) is located on the door frames and

contains 2% chrysotile asbestos. The material was observed to be in good condition.

Weber Elementary

No asbestos was detected in the materials sampled at this school.

Witt Elementary

No asbestos was detected in the materials sampled at this school.

Campbell Elementary

Approximately 80 SF of non-friable caulk (beige) is located on the door frames and contains

10% chrysotile asbestos. The material was observed to be in good condition.

8. RECOMMENDATIONS

Prior to renovation that will impact ACM, the material should be removed in accordance with

Regulation 8. There is a possibility that additional suspect ACM may be found during

renovation. In the event additional suspect materials, not sampled or assessed during this survey,

are discovered during renovation, Ninyo & Moore recommends one of the following:

Page 13: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc 5

(a) Samples of suspect materials should be collected for laboratory analysis and activities which

may impact the materials should cease until laboratory analysis is completed; or

(b) the materials should be assumed to be hazardous and handled as such.

9. LIMITATIONS

Ninyo & Moore's opinions and recommendations regarding environmental conditions, as

presented in this report, are based on limited sampling and analysis. The samples collected and

used for testing, and the observations made, are believed to be representative of the area(s)

evaluated. However, if additional suspect ACM is encountered during renovation or demolition

activities, these materials should be sampled by qualified personnel, and analyzed for asbestos

content prior to further disturbance. In addition, please note that quantities of ACM are

approximate. These numbers should be confirmed prior to removal or repair activities.

The environmental services described in this report have been conducted in general accordance

with current regulatory guidelines and the standard-of-care exercised by environmental

consultants performing similar work in the project area. No other warranty, expressed or implied,

is made regarding the professional opinions presented in this report. Variations in site conditions

may exist and conditions not observed or described in this report may be encountered during

subsequent activities. Please also note that this study did not include an evaluation of

geotechnical conditions or potential geologic hazards.

This document is intended to be used only in its entirety. No portion of the document, by itself, is

designed to completely represent any aspect of the project described herein. Ninyo & Moore

should be contacted if the reader requires any additional information, or has questions regarding

content, interpretations presented, or completeness of this document.

The environmental interpretations and opinions contained in this report are based on the results

of laboratory tests and analyses intended to detect the presence of ACM in samples collected

from the subject site. The testing and analyses have been conducted by an independent laboratory

which is accredited by the National Voluntary Laboratory Accreditation Program for bulk

Page 14: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc 6

asbestos fiber analysis. Ninyo & Moore has no involvement in, or control over, such testing and

analysis. Ninyo & Moore, therefore, disclaims responsibility for any inaccuracy in such

laboratory results.

Our conclusions, recommendations, and opinions are based on an analysis of the observed site

conditions. It should be understood that the conditions of a site can change with time as a result

of natural processes or the activities of man at the subject site or nearby sites. In addition,

changes to the applicable laws, regulations, codes, and standards of practice may occur due to

government action or the broadening of knowledge. The findings of this report may, therefore, be

invalidated over time, in part or in whole, by changes over which Ninyo & Moore has no control.

Page 15: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc

TABLES

Page 16: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

6155 West Leawood Drive Littleton, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 South Window Window Glazing (gray) Y D 15% Chrysotile

B-001B 1 West Window Window Glazing (gray) Y D 15% ChrysotileB-001C 1 North Window Window Glazing (gray) Y D 15% ChrysotileB-002A 1 South Window Window Caulk (light gray) N G NDB-002B 1 West Window Window Caulk (light gray) N G NDB-002C 1 North Window Window Caulk (light gray) N G NDB-003A 1 Northeast Window Window Glazing (clear) N G NDB-003B 1 Northeast Window Window Glazing (clear) N G NDB-003C 1 Northeast Window Window Glazing (clear) N G NDB-004A 1 Northeast Window Window Glazing (black) N G NDB-004B 1 Northeast Window Window Glazing (black) N G NDB-004C 1 Northeast Window Window Glazing (black) N G NDB-005A 1 Northeast Window Window Caulk (clear) N G NDB-005B 1 Northeast Window Window Caulk (clear) N G NDB-005C 1 Northeast Window Window Caulk (clear) N G ND

Notes:

5 SF

5 SF

Table 1. Asbestos Sample Results - Leawood Elementary

1 10 SF

2 10 SF

5 SF3

4

5

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly Damaged

HA = Homogeneous Area

SF = Square feet/ LF = Linear feet/ EA = EachND - None detected

501114001T.xlsx

Page 17: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

8455 West 88th Avenue Arvada, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 Cafeteria Window Caulk (Black/Gray) N G ND

B-001B 1 Cafeteria Window Caulk (Black/Gray) N G ND

B-001C 1 Cafeteria Window Caulk (Black/Gray) N G ND

B-002A 1 Exterior - Art Room Window Caulk (Black/Gray) N G ND

B-002B 1 Exterior - Art Room Window Caulk (Black/Gray) N G ND

B-002C 1 Exterior - Art Room Window Caulk (Black/Gray) N G ND

B-003A 1 Interior - Art Room Window Caulk (White/Gray) N G ND

B-003B 1 Interior - Art Room Window Caulk (Black/Gray) N G ND

B-003C 1 Interior - Teachers Lounge Window Caulk (Black/Gray) N G ND

B-004A 1 Interior - Teachers Lounge Window Caulk (Yellow) N G ND

B-004B 1 Exterior - Art Room Window Caulk (Yellow) N G ND

B-004C 1 Exterior - Art Room Window Caulk (Yellow) N G ND

1 Drywall (off-white/brown) N G ND

2 Joint Compound (white) N G ND

1 Drywall (off-white/brown) N G ND

2 Joint Compound (white) N G ND

1 Drywall (off-white/brown) N G ND

2 Joint Compound (white) N G ND

1 Mastic (Black/Gray) N G ND

2 Mastic (White/Gray) N G ND

1 Mastic (Black/Gray) N G ND

2 Mastic (White/Gray) N G ND

1 Mastic (Black/Gray) N G ND

2 Mastic (White/Gray) N G ND

Notes:

N/M

N/M

Roof (Clerestory Window)

Roof (Clerestory Window)

Roof (Clerestory Window)

Corridor Wall

Corridor Wall

Corridor Wall

5

6

B-005A

B-005B

B-005C

B-006A

B-006B

B-006C

Table 2. Asbestos Sample Results - Moore Middle

1

2

3

4

N/M

N/M

N/M

N/M

NM = Not Measured

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

ND = None Detected

Page 18: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

11025 West Glennon Drive Lakewood, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 Exterior Window Window Glazing (white/light gray) Y SD ND

B-001B 1 Exterior Window Window Glazing (white/light gray) Y SD ND

B-001C 1 Exterior Window Window Glazing (white/light gray) Y SD ND

B-001D 1 Exterior Window Window Glazing (light gray) Y SD ND

B-001E 1 Exterior Window Window Glazing (light gray) Y SD ND

B-001F 1 Exterior Window Window Glazing (light gray) Y SD ND

B-002A 1 Exterior Window Window Caulk (light gray) N G 8% chrysotile

B-002B 1 Exterior Window Window Caulk (light gray) N G 8% chrysotile

B-002C 1 Exterior Window Window Caulk (light gray) N G 5% chrysotile

B-002D 1 Exterior Window Window Caulk (white/gray) N G ND

B-002E 1 Exterior Window Window Caulk (gray) N G ND

B-002F 1 Exterior Window Window Caulk (light gray/white) N G 8% chrysotile

Notes:

Table 3. Asbestos Sample Results - Glennon Heights Elementary

1

2

200 SF

50 SF

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

ND = None detected

Page 19: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

7655 West 10th Avenue Lakewood, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 Room 208 - Wall Plaster (off-white) Y G N/M ND

B-001B 1 Room 210 - Wall Plaster (off-white) Y G N/M ND

B-001C 1 Room 211B - Wall Plaster (off-white) Y G N/M ND

B-001D 1 Room 208 - Wall Plaster (off-white) Y G N/M ND

1 Drywall (white/brown) N G N/M ND

2 Joint Compound (white) N G N/M ND

1 Drywall (white/brown) N G N/M ND

2 Joint Compound (white) N G N/M ND

1 Drywall (white/brown) N G N/M ND

2 Joint Compound (white) N G N/M ND

B-003A 1 Room B109 - Exterior Door Caulk (black/tan) N G 20 SF 3% chrysotile

B-003B 1 Room B105 - Door Caulk (black/tan) N G 20 SF 3% chrysotile

B-003C 1 Room B-113 Door Caulk (black/tan) N G 20 SF 3% chrysotile

B-004A 1 Gym - Exterior Door Caulk (gray/tan) N G N/M ND

B-004B 1 Gym - Exterior Door Caulk (gray/tan) N G N/M ND

B-004C 1 Gym - Exterior Door Caulk (gray/tan) N G N/M ND

Notes:

Table 4. Asbestos Sample Results - Jeffco Open Elementary

B-002C

B-002A

B-002B

4

3

2

1

Room 215 - Wall

Room 205 - Wall

Room 215 - Wall

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 20: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

8605 West 23rd Avenue Lakewood, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 Cafeteria Mortar (beige) Y G ND

B-001B 1 Room 037 Mortar (beige) Y G ND

B-001C 1 Room B4 Mortar (beige) Y G ND

B-002A 1 Gym Caulk (blue/beige) N G 5% chrysotile

B-002B 1 Room C1 Caulk (blue/beige) N G 7% chrysotile

B-002C 1 Room B4 Caulk (blue/beige) N G 7% chrysotile

Notes:

Table 5. Asbestos Sample Results - Slater Elementary

1

2 30 SF

N/M

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 21: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

1385 Indenpendence Street Lakewood, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 Room A1 Caulk (beige) N G 10% chrysotile

B-001B 1 Room B107 Caulk (beige/red) N G 8% chrysotile

B-001C 1 Room C107 Caulk (beige/tan) N G 5% chrysotile

B-001D 1 Room C3 Caulk (beige/tan) N G 5% chrysotile

1 Carpet Mastic (yellow) N G ND

2 Carpet Pad (gray) N G ND

Notes:

Table 6. Asbestos Sample Results - Eiber Elementary

1

B-002A 2

40 SF

N/MRoom B107

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 22: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

6705 West 23rd Avenue Edgewater, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

1 Drywall (white/brown) N G ND

2 Vinyl Cove Base Mastic (tan) N G ND

1 Drywall (white/brown) N G ND

2 Adhesive (brown) N G ND

3 Vinyl Cove Base Mastic (tan) N G ND

1 Drywall (white/brown) N G ND

2 Adhesive (brown) N G ND

3 Vinyl Cove Base Mastic (tan) N G ND

B-002A 1 DC103 Caulk (yellow/gray/blue) N G 5% chrysotile

B-002B 1 D100A Caulk (yellow/gray/blue) N G 5% chrysotile

B-002C 1 D117 Caulk (yellow/gray/blue) N G 5% chrysotile

1 CMU (gray) N G ND

2 Paint (multi-colored) N G ND

B-003B 1 DC101 Paint (white) N G ND

1 CMU (gray) N G ND

2 Paint (cream) N G ND

B-004A 1 D101 Caulk (white/green) N G 2% chrysotile

B-004B 1 D04 Caulk (white/green) N G ND

B-004C 1 D06 Caulk (white/green) N G ND

Notes:

20 SF

D06

D100

DC103

D100

D06B-003C

1

2

3

4

Table 7. Asbestos Sample Results - Lumberg Elementary

B-001A

B-001B

B-001C

B-003A

N/M

20 SF

N/M

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 23: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

8725 West 81st Place Arvada, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

1 Drywall (off-white/brown) N G ND

2 Joint compound (white) N G ND

3 Caulk (white) N G ND

1 Drywall (off-white/brown) N G ND

2 Joint compound (off-white) N G ND

1 Drywall (off-white/brown) N G ND

2 Joint compound (off-white) N G ND

B-002A 1 Facility Manager Office Caulk (white) N G ND

B-002B 1 Facility Manager Office Caulk (white) N G ND

B-002C 1 Facility Manager Office Caulk (white) N G ND

B-003A 1 Entrance to Cafeteria Caulk (tan/light gray) N G ND

B-003B 1 Entrance to Cafeteria Caulk (tan/light gray) N G ND

B-003C 1 Entrance to Cafeteria Caulk (tan/light gray) N G ND

Notes:

2

3

20 SF

20 SF

N/M

Facility Manager Office

Facility Manager Office

Entrance to Cafeteria

Table 8. Asbestos Sample Results - Weber Elementary

B-001C

B-001B

B-001A

1

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 24: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

10255 West 104th Avenue Westminster, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 G119 - Wall CMU (black/gray) N G ND

B-001B 1 G119 - Wall CMU (black/gray) N G ND

B-001C 1 G119 - Wall CMU (black/gray) N G ND

B-002A 1 S104 - Window Caulk (gray) N G ND

B-002B 1 S104 - Window Caulk (gray) N G ND

B-002C 1 G119 - Wall Caulk (gray) N G ND

Notes:

Table 9. Asbestos Sample Results - Witt Elementary

1

2

N/M

N/M

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 25: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

6500 Oak Street Arvada, Colorado

March 1, 2016Project No. 501114001

Sample No.

HA Layer Sample Location Sample DescriptionFriable (Y/N)

Condition (G/D/SD)

Approximate Quantity

(SF/LF/EA)

Asbestos Content

B-001A 1 Interior - Art Room CMU (gray) N G ND

B-001B 1 Interior - Corridor E CMU (gray) N G ND

B-001C 1 Interior - Corridor F CMU (gray) N G ND

B-001D 1 Exterior - Corridor F CMU (gray) N G ND

B-001E 1 Interior - Mechanical Room CMU (gray) N G ND

B-002A 1 Interior - Corridor F Caulk (beige) N G 10% chrysotile

B-002B 1 Interior - Room 11 Caulk (beige) N G 5% chrysotile

B-002C 1 Interior - Room 8 Caulk (beige) N G 10% chrysotile

B-003A 1 Exterior - Room 19 Caulk (beige) N G 10% chrysotile

B-003B 1 Exterior - Room 13 Caulk (beige) N G 10% chrysotile

B-003C 1 Exterior - Corridor E Caulk (beige) N G 10% chrysotile

Notes:

Table 10. Asbestos Sample Results - Campbell Elementary

1

2

3

N/M

40 SF

40 SF

ND = None Detected

HA = Homogeneous Area

Y/N = Yes/No

G/D/SD = Good/Damaged/Slightly DamagedSF = Square feet/ LF = Linear feet/ EA = Each

NM = Not Measured

Page 26: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc

APPENDIX A

LABORATORY REPORT AND CHAIN-OF-CUSTODY RECORD

Page 27: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166657

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/09/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: LEAWOOD

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesWindow Glazing, Gray Chrysotile0166657-001 S. WINDOW

B-001A

15%

CarbonatesQuartzBinder/Filler

85%

YesWindow Glazing, Gray Chrysotile0166657-002 W. WINDOW

B-001B

15%

CarbonatesQuartzBinder/Filler

85%

YesWindow Glazing, Gray Chrysotile0166657-003 N. WINDOW

B-001C

15%

CarbonatesQuartzBinder/Filler

85%

NoWindow Caulking, Lt. Gray None Detected0166657-004 S. WINDOW

B-002A CarbonatesQuartzBinder/Filler

100%

NoWindow Caulking, Lt. Gray None Detected0166657-005 W. WINDOW

B-002B CarbonatesQuartzBinder/Filler

100%

Fibrous GlassNoWindow Caulking, Lt. Gray None Detected0166657-006 N. WINDOW

B-002C

2%

CarbonatesQuartzBinder/Filler

98%

Page 1 of 2

Page 28: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166657

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/09/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: LEAWOOD

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Analyst - Kenneth Scheske Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 29: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 30: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 31: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166977

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

EPA Method: Project Name: JEFFCO SCHOOL-LEAWOOD ELEMENTARY Submitted By: ROBERT NEUMANN

Address:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoWindow Glaze, Clear None Detected0166977-001 NE BLDG CORNER

B-003A SiliconeBinder/Filler

100%

NoWindow Glaze, Clear None Detected0166977-002 NE BLDG CORNER

B-003B SiliconeBinder/Filler

100%

NoWindow Glaze, Clear None Detected0166977-003 NE BLDG CORNER

B-003C SiliconeBinder/Filler

100%

NoWindow Glaze, Black None Detected0166977-004 NE BLDG CORNER

B-004A CarbonatesQuartzSiliconeBinder/Filler

100%

NoWindow Glaze, Black None Detected0166977-005 NE BLDG CORNER

B-004B CarbonatesQuartzSiliconeBinder/Filler

100%

NoWindow Glaze, Black None Detected0166977-006 NE BLDG CORNER

B-004C CarbonatesQuartzSiliconeBinder/Filler

100%

NoWindow Caulking, Clear None Detected0166977-007 NE BLDG CORNER

B-005A CarbonatesQuartzSiliconeBinder/Filler

100%

Page 1 of 2

Page 32: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166977

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

EPA Method: Project Name: JEFFCO SCHOOL-LEAWOOD ELEMENTARY Submitted By: ROBERT NEUMANN

Address:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoWindow Caulking, Clear None Detected0166977-008 NE BLDG CORNER

B-005B CarbonatesQuartzSiliconeBinder/Filler

100%

NoWindow Caulking, Clear None Detected0166977-009 NE BLDG CORNER

B-005C CarbonatesQuartzSiliconeBinder/Filler

100%

Analyst - Kurt Kettler Signatory - Lab Manager - Ken Scheske

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 33: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 34: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 35: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166976

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoWindow Caulk, Black/ Gray None Detected0166976-001 CAFETERIA

B-001A CarbonatesGypsumQuartzBinder/Filler

100%

NoWindow Caulk, Black/ Gray None Detected0166976-002 CAFETERIA

B-001B CarbonatesGypsumQuartzBinder/Filler

100%

NoWindow Caulk, Black/ Gray None Detected0166976-003 CAFETERIA

B-001C CarbonatesGypsumQuartzBinder/Filler

100%

NoWindow Caulk, Black/ Gray None Detected0166976-004 EXTERIOR-ART RM

B-002A CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoWindow Caulk, Black/ Gray None Detected0166976-005 EXTERIOR-ART RM

B-002B

<1%

CarbonatesQuartzBinder/Filler

99%

NoWindow Caulk, Black/ Gray None Detected0166976-006 EXTERIOR-ART RM

B-002C CarbonatesQuartzBinder/Filler

100%

Synthetic FiberNoWindow Caulk/ Paint, White/ Gray None Detected0166976-007 INTERIOR-ART RM

B-003A

<1%

CarbonatesQuartzBinder/Filler

99%

Page 1 of 5

Page 36: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166976

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoWindow Caulk, Black/ Gray None Detected0166976-008 INTERIOR-ART RM

B-003B CarbonatesGypsumQuartzBinder/Filler

100%

NoWindow Caulk, Black/ Gray None Detected0166976-009 INTERIOR-TEACHERS LOUNGE

B-003C

CarbonatesGypsumQuartzBinder/Filler

100%

NoWindow Caulk, Yellow None Detected0166976-010 INTERIOR-TEACHERS LOUNGE

B-004A

CarbonatesSiliconeBinder/Filler

100%

NoWindow Caulk, Yellow None Detected0166976-011 EXTERIOR-ART RM

B-004B CarbonatesSiliconeBinder/Filler

100%

NoWindow Caulk, Yellow None Detected0166976-012 EXTERIOR-ART RM

B-004C CarbonatesSiliconeBinder/Filler

100%

Page 2 of 5

Page 37: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166976

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0166976-013 CORRIDOR

B-005A

12%

GypsumQuartzCarbonates

88%

Cellulose FiberNoLAYER 2Joint Compound/ Paint, White/ Off WhiteNote: Layer is mainly Paint - little Compound present

None Detected 1%

CarbonatesGypsumMicaQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0166976-014 CORRIDOR

B-005B

12%

GypsumQuartzCarbonates

88%

Cellulose FiberNoLAYER 2Joint Compound/ Paint, White/ Off WhiteNote: Layer is mainly Paint - little Compound present

None Detected 1%

CarbonatesGypsumMicaQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0166976-015 CORRIDOR

B-005C

12%

GypsumQuartzCarbonates

88%

Cellulose FiberNoLAYER 2Joint Compound/ Paint, White/ Off WhiteNote: Layer is mainly Paint - little Compound present

None Detected 1%

CarbonatesGypsumMicaQuartzBinder/Filler

99%

Page 3 of 5

Page 38: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166976

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoLAYER 1Mastic, Black/ Gray

None Detected0166976-016 WINDOWS (ROOF)

B-006A

<1%

CarbonatesGypsumQuartzBinder/Filler

99%

NoLAYER 2Mastic, White/ Gray

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

NoLAYER 1Mastic, Black/ Gray

None Detected0166976-017 WINDOWS (ROOF)

B-006B CarbonatesGypsumQuartzBinder/Filler

100%

NoLAYER 2Mastic, White/ Gray

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

NoLAYER 1Mastic, Black/ Gray

None Detected0166976-018 WINDOWS (ROOF)

B-006C CarbonatesGypsumQuartzBinder/Filler

100%

NoLAYER 2Mastic, White/ Gray

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

Page 4 of 5

Page 39: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166976

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/23/2016

02/26/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/22/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/26/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Analyst - James A. Storm Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 5 of 5

Page 40: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 41: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 42: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 43: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166659

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/09/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: GLENNON HEIGHTS Submitted By: MARK WILLIAMS

Address:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoWindow Glazing, White/ Lt. Gray None Detected0166659-001 EXTERIOR-RM 54

B-001A CarbonatesQuartzBinder/Filler

100%

NoWindow Glazing, White/ Lt. Gray None Detected0166659-002 EXTERIOR-GYM STORAGE 2B-001B

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoWindow Glazing, White/ Lt. Gray None Detected0166659-003 EXTERIOR-CAFETERIAB-001C

<1%

CarbonatesQuartzBinder/Filler

99%

NoWindow Glazing, Lt. Gray None Detected0166659-004 EXTERIOR-RM 42

B-001D CarbonatesQuartzBinder/Filler

100%

NoWindow Glazing, White/ Lt. Gray None Detected0166659-005 EXTERIOR-RM 73

B-001E CarbonatesQuartzBinder/Filler

100%

NoWindow Glazing, Lt. Gray None Detected0166659-006 EXTERIOR-RM 67

B-001F CarbonatesQuartzBinder/Filler

100%

YesWindow Caulking, Lt. Gray Chrysotile0166659-007 EXTERIOR-RM 57

B-002A

8%

CarbonatesQuartzBinder/Filler

92%

Page 1 of 2

Page 44: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166659

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/09/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: GLENNON HEIGHTS Submitted By: MARK WILLIAMS

Address:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesWindow Caulking, Lt. Gray Chrysotile0166659-008 EXTERIOR-RM 21

B-002B

8%

CarbonatesQuartzBinder/Filler

92%

YesWindow Caulking, Lt. Gray Chrysotile0166659-009 EXTERIOR-RM 32

B-002C

5%

CarbonatesQuartzGypsumBinder/Filler

95%

Cellulose FiberNoWindow Caulking, White/ Gray None Detected0166659-010 EXTERIOR-RM 41

B-002D

<1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberNoWindow Caulking, Gray None Detected0166659-011 EXTERIOR-RM 79

B-002E

<1%

CarbonatesQuartzBinder/Filler

99%

YesWindow Caulking, Lt. Gray/White Chrysotile0166659-012 EXTERIOR-RM 67

B-002F

8%

CarbonatesQuartzBinder/Filler

92%

Analyst - Kurt Kettler Signatory - Lab Manager - Ken Scheske

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 45: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 46: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 47: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166658

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: JEFFCO OPEN

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoPlaster/ Paint, White/ Off WhiteNote: Sample is mainly Paint - no Plaster present

None Detected0166658-001 RM 208

B-001A CarbonatesQuartzBinder/Filler

100%

NoPlaster/ Paint, White/ Off WhiteNote: Sample is mainly Paint - no Plaster present

None Detected0166658-002 RM 210

B-001B CarbonatesQuartzBinder/Filler

100%

NoPlaster/ Paint, Off White None Detected0166658-003 RM 211B

B-001C GypsumQuartzCarbonatesMicaBinder/Filler

100%

NoPlaster/ Paint, Off White None Detected0166658-004 RM 208

B-001D GypsumQuartzCarbonatesMicaBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, White/ BrownNote: Very small amount of Drywall

None Detected0166658-005 RM 205

B-002A

12%

GypsumCarbonatesMica

88%

Cellulose FiberNoLAYER 2Joint Compound, White

None Detected <1%

CarbonatesPerliteMicaQuartzBinder/Filler

99%

Page 1 of 3

Page 48: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166658

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: JEFFCO OPEN

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Drywall, White/ Brown

None Detected0166658-006 RM 215

B-002B

10%2%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White

None Detected 2%

CarbonatesPerliteMicaQuartzBinder/Filler

98%

Cellulose FiberFibrous Glass

NoLAYER 1Drywall, White/ Brown

None Detected0166658-007 RM 215

B-002C

10%2%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White

None Detected 1%

CarbonatesPerliteMicaQuartzBinder/Filler

99%

YesCaulk, Black/ Tan Chrysotile0166658-008 EXTERIOR @ B109

B-003A

3%

CarbonatesQuartzGypsumBinder/Filler

97%

YesCaulk, Black/ Tan Chrysotile0166658-009 B-105

B-003B

3%

CarbonatesQuartzGypsumBinder/Filler

97%

Page 2 of 3

Page 49: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166658

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: JEFFCO OPEN

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesCaulk, Black/ Tan Chrysotile0166658-010 B-113

B-003C

3%

CarbonatesQuartzGypsumBinder/Filler

97%

NoCaulking, Gray/Tan None Detected0166658-011 EXTERIO GYM DOORB-004A

CarbonatesQuartzBinder/Filler

100%

NoCaulking, Gray/Tan None Detected0166658-012 EXTERIO GYM DOORB-004B

CarbonatesQuartzBinder/Filler

100%

NoCaulking, Gray/Tan None Detected0166658-013 EXTERIO GYM DOORB-004C

CarbonatesQuartzBinder/Filler

100%

Analyst - Kenneth Scheske Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 3 of 3

Page 50: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 51: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 52: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166661

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: SLATER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoMortar, Beige None Detected0166661-001 CAFETERIA DOOR

B-001A

<1%

QuartzGypsumCarbonatesMicaBinder/Filler

99%

Cellulose FiberNoMortar, Beige None Detected0166661-002 RM 037

B-001B

1%

QuartzGypsumCarbonatesMicaBinder/Filler

99%

Cellulose FiberNoMortar, Beige None Detected0166661-003 RM B4

B-001C

1%

QuartzGypsumCarbonatesMicaBinder/Filler

99%

Cellulose FiberYesCaulking, Blue/ Beige Chrysotile0166661-004 GYM DOOR

B-002A

5% 2%

CarbonatesQuartzBinder/Filler

93%

Cellulose FiberYesCaulking, Blue/ Beige Chrysotile0166661-005 RM C1

B-002B

7% 3%

CarbonatesQuartzBinder/Filler

90%

WollastoniteCellulose Fiber

YesCaulking, Blue/ Beige Chrysotile0166661-006 RM B4

B-002C

7% 2%1%

CarbonatesQuartzBinder/Filler

90%

Page 1 of 2

Page 53: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166661

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: SLATER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Analyst - Johann Hofer Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 54: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 55: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 56: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166655

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/09/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: EIBER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

TalcYesCaulking, Beige Chrysotile0166655-001 RM A-1

B-001A

10% 2%

CarbonatesMicaQuartzBinder/Filler

88%

TalcYesCaulking, Beige/ Red Chrysotile0166655-002 RM B107

B-001B

8% 2%

CarbonatesMicaQuartzBinder/Filler

90%

TalcYesCaulking, Beige/ Tan Chrysotile0166655-003 RM C107

B-001C

5% 5%

CarbonatesMicaQuartzBinder/Filler

90%

TalcYesCaulking, Beige/ Tan Chrysotile0166655-004 RM C-3

B-001D

5% 7%

CarbonatesMicaQuartzBinder/Filler

88%

Synthetic FiberNoLAYER 1Carpet Mastic, Yellow

None Detected0166655-005 RM B107

B-002A

2%

CarbonatesGypsumBinder/Filler

98%

Synthetic FiberNoLAYER 2Carpet Pads, Gray

None Detected 1%

FoamCarbonatesBinder/Filler

99%

Page 1 of 2

Page 57: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166655

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/09/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: EIBER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Analyst - Johann Hofer Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 58: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 59: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 60: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0167007

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/24/2016

02/25/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/23/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS-LUMBERG

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/25/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, White/ BrownNote: No Joint Compound or Texture Present

None Detected0167007-001 S. WING

B-001A

12%

GypsumQuartzCarbonates

88%

TalcWollastonite

NoLAYER 2Adhesive, Tan

None Detected 2%2%

CarbonatesGypsumQuartzBinder/Filler

96%

Cellulose FiberNoLAYER 1Drywall, White/ BrownNote: No Joint Compound or Texture Present

None Detected0167007-002 MENS RR

B-001B

12%

GypsumQuartzCarbonates

88%

Cellulose FiberNoLAYER 2Adhesive/Paint, Brown/White

None Detected 1%

CarbonatesGypsumQuartzBinder/Filler

99%

WollastoniteTalc

NoLAYER 3Adhesive, Tan

None Detected 3%2%

CarbonatesGypsumQuartzBinder/Filler

95%

Page 1 of 4

Page 61: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0167007

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/24/2016

02/25/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/23/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS-LUMBERG

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/25/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, White/ BrownNote: No Joint Compound or Texture Present

None Detected0167007-003 ACROSS FROM LIBRARYB-001C

12%

GypsumQuartzCarbonates

88%

Cellulose FiberNoLAYER 2Adhesive/Paint, Brown/White

None Detected 1%

CarbonatesGypsumQuartzBinder/Filler

99%

WollastoniteTalc

NoLAYER 3Adhesive, Tan

None Detected 4%1%

CarbonatesGypsumQuartzBinder/Filler

95%

YesCaulk, Yellow/ Gray/ Blue Chrysotile0167007-004 ACROSS FROM LIBRARYB-002A

5%

CarbonatesQuartzBinder/Filler

95%

YesCaulk, Yellow/ Gray/ Blue Chrysotile0167007-005 MENS RR

B-002B

5%

CarbonatesQuartzBinder/Filler

95%

YesCaulk, Yellow/ Gray/ Blue Chrysotile0167007-006 W. WING

B-002C

5%

CarbonatesQuartzBinder/Filler

95%

Page 2 of 4

Page 62: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0167007

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/24/2016

02/25/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/23/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS-LUMBERG

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/25/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1CMU, Gray

None Detected0167007-007 ASSISTANT PRINCIPALB-003A

<1%

QuartzGypsumMicaCarbonatesBinder/Filler

99%

Cellulose FiberNoLAYER 2CMU Paint, Cream/Multicolored

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Fibrous GlassNoCMU Paint, WhiteNote: No CMU Present

None Detected0167007-008 ACROSS FROM LIBRARYB-003B

<1%

CarbonatesMicaQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1CMU, Gray

None Detected0167007-009 CLASSRM 6

B-003C

<1%

QuartzGypsumMicaCarbonatesBinder/Filler

99%

Cellulose FiberNoLAYER 2CMU Paint, Cream

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

TalcYesCaulk, White/ Green Chrysotile0167007-010 B-101

B-004A

2% 3%

CarbonatesQuartzBinder/Filler

95%

Cellulose FiberNoCaulk, White/ Green None Detected0167007-011 CLASSRM 4

B-004B

<1%

CarbonatesQuartzBinder/Filler

99%

Page 3 of 4

Page 63: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0167007

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/24/2016

02/25/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/23/2016

501114001

EPA Method: Project Name: JEFFCO SCHOOLS-LUMBERG

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/25/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoCaulk, White/ Green None Detected0167007-012 CLASSRM 6

B-004C

<1%

CarbonatesQuartzBinder/Filler

99%

Analyst - Kurt Kettler Signatory - Lab Manager - Ken Scheske

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 4 of 4

Page 64: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 65: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 66: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166656

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: WEBER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0166656-001 FM OFFICE

B-001A

12%

GypsumQuartzCarbonates

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Lt. Blue

None Detected <1%

CarbonatesMicaQuartzPerliteBinder/Filler

99%

NoLAYER 3Caulking, White

None Detected

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, White/ Brown

None Detected0166656-002 FM OFFICE

B-001B

10%

GypsumQuartzCarbonates

90%

NoLAYER 2Joint Compound, Off White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, White/ Brown

None Detected0166656-003 CAFETERIA

B-001C

10%

GypsumQuartzCarbonates

90%

NoLAYER 2Joint Compound, Off White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Page 1 of 3

Page 67: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166656

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: WEBER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoCaulking, White None Detected0166656-004 FM OFFICE

B-002A CarbonatesQuartzBinder/Filler

100%

NoCaulking, White None Detected0166656-005 FM OFFICE

B-002B CarbonatesQuartzBinder/Filler

100%

NoCaulking, White None Detected0166656-006 FM OFFICE

B-002C CarbonatesQuartzBinder/Filler

100%

NoCaulking, Tan/ Lt. Gray None Detected0166656-007 CAFETERIA

B-002A CarbonatesQuartzBinder/Filler

100%

NoCaulking, Tan/ Lt. Gray None Detected0166656-008 CAFETERIA

B-002B CarbonatesQuartzBinder/Filler

100%

NoCaulking, Tan/ Lt. Gray None Detected0166656-009 CAFETERIA

B-002C CarbonatesQuartzBinder/Filler

100%

Page 2 of 3

Page 68: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166656

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: WEBER

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Analyst - Kurt Kettler Signatory - Lab Manager - Ken Scheske

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 3 of 3

Page 69: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 70: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 71: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166660

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: WITT

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoCMU, Black/ Gray None Detected0166660-001 STORAGE RM

B-001A

<1%

QuartzGypsumMicaCarbonatesBinder/Filler

99%

NoCMU, Black/ Gray None Detected0166660-002 STORAGE RM

B-001B QuartzGypsumMicaCarbonatesBinder/Filler

100%

Cellulose FiberNoCMU, Black/ Gray None Detected0166660-003 STORAGE RM

B-001C

<1%

QuartzGypsumMicaCarbonatesBinder/Filler

99%

NoCaulking, Gray None Detected0166660-004 WINDOWS

B-002A CarbonatesQuartzBinder/Filler

100%

NoCaulking, Gray None Detected0166660-005 WINDOWS

B-002B CarbonatesQuartzBinder/Filler

100%

NoCaulking, Gray None Detected0166660-006 STORAGE RM DOORB-002C

CarbonatesQuartzBinder/Filler

100%

Page 1 of 2

Page 72: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166660

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/19/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: WITT

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Analyst - Kurt Kettler Signatory - Lab Manager - Ken Scheske

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 73: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 74: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 75: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166662

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/17/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: CAMPBELL

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoCMU, Gray None Detected0166662-001 ART RM

B-001A

<1%

GypsumQuartzCarbonatesMicaBinder/Filler

99%

Cellulose FiberNoCMU, Gray None Detected0166662-002 CORRIDOR (18/15)

B-001B

<1%

GypsumQuartzCarbonatesMicaBinder/Filler

99%

Cellulose FiberNoCMU, Gray None Detected0166662-003 CORRIDOR (12/13)

B-001C

<1%

GypsumQuartzCarbonatesMicaBinder/Filler

99%

Cellulose FiberNoCMU, Gray None Detected0166662-004 CORRIDOR (12/13 EXTERIOR)B-001D

<1%

GypsumQuartzCarbonatesMicaBinder/Filler

99%

Cellulose FiberNoCMU, Gray None Detected0166662-005 MECH RM

B-001E

1%

GypsumQuartzCarbonatesMicaBinder/Filler

99%

YesInterior Caulking, Beige Chrysotile0166662-006 CORRIDOR F

B-002A

10%

CarbonatesQuartzBinder/Filler

90%

Page 1 of 2

Page 76: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0166662

NVLAP#101926-0

Client ID

Client:Address: 6001 S. WILLOW DR, STE 195

GREENWOOD VILLAGE CO 80111

NINYO & MOORE

Date Received: 02/16/2016

02/17/2016Date Analyzed:

501114001Job# / P.O. #:

EMC LABS, INC.

Collected: 02/08/2016

EPA Method: Project Name: JEFFCO SCHOOL TASK: CAMPBELL

Submitted By: MARK WILLIAMSAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

02/19/2016Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesInterior Caulking, Beige Chrysotile0166662-007 RM 11

B-002B

10%

CarbonatesQuartzBinder/Filler

90%

Cellulose FiberYesInterior Caulking, Beige Chrysotile0166662-008 RM 8

B-002C

5% 1%

CarbonatesQuartzBinder/Filler

94%

YesExterior Caulking, Beige Chrysotile0166662-009 RM 19

B-003A

10%

CarbonatesQuartzBinder/Filler

90%

Cellulose FiberYesExterior Caulking, Beige Chrysotile0166662-010 RM 13

B-003B

10% 2%

CarbonatesQuartzBinder/Filler

88%

YesExterior Caulking, Beige Chrysotile0166662-011 CORRIDOR E

B-003C

10%

CarbonatesQuartzBinder/Filler

90%

Analyst - Johann Hofer Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Page 2 of 2

Page 77: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 78: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 79: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco Warm, Safe, & Dry 2016 March 1, 2016

Jefferson County, Colorado Project No. 501114001

501114001R.doc

APPENDIX B

CERTIFICATIONS

Page 80: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 81: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 82: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected
Page 83: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OFNON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION.SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET.

SHEET KEYNOTES

101 ASBESTOS CONTRACTOR TO REMOVE EXISTING WINDOW SYSTEM.PROVIDE NEW ALUMINUM STOREFRONT / ALUMINUM WINDOW /HOLLOW METAL WINDOW SYSTEM WITH INSULATED GLAZING, RE:DRAWINGS FOR TYPE AND LOCATION.

102 BASE BID: APPLY 08 8750 SOLAR CONTROL GLAZING FILM TO INSIDEFACE OF EXISTING GLAZING. ALTERNATE A1: GENERAL CONTRACTORCONTRACTOR TO REMOVE EXISTING WINDOW SYSTEM, (WITH-IN)EXISTING STEEL FRAME TO REMAIN, PROVIDE NEW ALUMINUMSTOREFRONT SYSTEM WITH INSULATED GLAZING.

103 ASBESTOS CONTRACTOR TO REMOVE EXISTING EXTERIOR WOODDOORS AND FRAME. PROVIDE NEW HOLLOW METAL DOORS, HOLLOWMETAL FRAME AND HARDWARE.

104 GENERAL CONTRACTOR TO REMOVE EXISTING INTERIOR WOODDOOR. ASBESTOS CONTRACTOR TO REMOVE EXISTING WOOD DOORFRAME. PROVIDE NEW WOOD DOOR, HOLLOW METAL FRAME ANDHARDWARE.

105 GENERAL CONTRACTOR TO REMOVE EXISTING INTERIOR WOODDOOR(S) AND IN-FLOOR CLOSER(S). ASBESTOS CONTRACTOR TOREMOVE EXISTING HM DOOR FRAME. PROVIDE NEW WOOD DOOR(S),HOLLOW METAL FRAME AND HARDWARE. REPAIR FLOOR SLAB /CARPET AS REQUIRED.

106 ASBESTOS CONTRACTOR TO REMOVE EXISTING INTERIOR QUARRYTILE SILL ALL ALONG WINDOW OPENING.

107 GENERAL CONTRACTOR TO REMOVE EXISTING EXTERIOR HOLLOWMETAL DOOR(S), EXISTING FRAME TO REMAIN. PROVIDE NEW HOLLOWMETAL DOOR(S) AND HARDWARE.

108 ASBESTOS CONTRACTOR TO REMOVE EXISTING EXTERIOR HOLLOWMETAL DOOR(S) AND FRAME. PROVIDE NEW HOLLOW METALDOORS(S), HOLLOW METAL FRAME AND HARDWARE.

110 GENERAL CONTRACTOR TO REMOVE EXISTING DOOR, STORE,PROTECT FOR REINSTALLATION.

111 GENERAL CONTRACTOR TO REMOVE EXISTING SPIRAL DUCTTHROUGH DOOR TRANSOME, STORE , PROTECT FORREINSTALLATION.

112 GENERAL CONTRACTOR TO REMOVE EXISTING WINDOW SYSTEM.PROVIDE NEW ALUMINUM STOREFRONT / ALUMINUM WINDOW /HOLLOW METAL WINDOW SYSTEM WITH INSULATED GLAZING, RE:DRAWINGS FOR TYPE AND LOCATION.

113 GENERAL CONTRACTOR TO REMOVE EXISTING EXTERIOR WOODDOORS AND FRAME. PROVIDE NEW HOLLOW METAL DOORS, HOLLOWMETAL FRAME AND HARDWARE.

114 GENERAL CONTRACTOR TO REMOVE EXISTING EXTERIOR HOLLOWMETAL DOOR(S) AND FRAME. PROVIDE NEW HOLLOW METALDOORS(S), HOLLOW METAL FRAME AND HARDWARE.

201 PROVIDE NEW ADA AUTOMATIC DOOR OPENER AND PUSH BUTTONACTUATORS ON EXISTING DOOR.

202 GENRAL CONTRACTOR TO REMOVE EXISTING WINDOW COVERING.PROVIDE 12 2113.01 HORIZONTAL LOUVER BLIND AT EACH WINODOWUNIT, FULL HEIGHT OF WINDOW.

203 GENERAL CONTRACTOR TO REMOVE EXISTING ALUMINUM DOOR ANDSUB-FRAME, EXISTING CURTAIN WALL FRAMING TO REMAIN. PROVIDE08 3413.11 ALUMINUM STOREFRONT DOOR, SUBFRAME ANDHARDWARE.

204 EXISTING CARD READER TO REMAIN, CONNECT TO NEW ELECTRICSTRIKE.

Jeffco WS&D 2016

Addendum No. 1 SHEET KEYNOTES

03/16/2016

15137.00

AD01-A1

Page 84: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco WS&D 2016

Addendum No. 1 LEAWOOD ES PARTIAL FLOOR PLAN

03/16/2016

15137.00

AD01-A2

DRY STOR

E109KITCHEN

WORK

RMCLASSROOM

16

VEST

E119AMUSIC

E22

CORR

183

FM

24

B RRCORR

CLASSROOM

31

CLASSROOM

29

CLASSROOM

27

CLASSROOM

25

G RR

187

STOR

184ART

23

KILN

197

BOILER

181CORR

180

CAFETERIA

179

ELEC

178

AB-a

AB-b

AC

112

AC

112

AC AD

112

110AD

112

112

110

112 112

Page 85: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco WS&D 2016

Addendum No. 1 LEAWOOD ES WDO ELEVATIONS &DETAILS

03/16/2016

15137.00

AD01-A3

LINE OF EXISTING SILL BELOW

09 2116.72 ADJUSTABLE PARTITION CLOSUREEXISTING NEOPRENE CLOSURE TO REMAINABOVE AND BELOW WINDOW OPENING

08 4313.01 ALUMINUM FRAMED STOREFRONT SYSTEM

EXISTING PARTITION TO REMAIN

4 1/

4"

1 1/2" = 1'-0"

LEAWOOD ES MULLION AT EXISTING PARTIION10

Page 86: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco WS&D 2016

Addendum No. 1 MOORE MS PARTIAL ROOF PLAN

03/16/2016

15137.00

AD01-A4

112112

112112

112101

112112

BFBF

BF BF

BF BF

BF BF

112

Page 87: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco WS&D 2016

Addendum No. 1 JEFFCO OPEN SCHOOL FIRST FLOOR PLAN

03/16/2016

15137.00

AD01-A5

STORAGE

E-102

E-104

STAIRS

E-103

VESTIBULE 113

113

A103A

A103B

Page 88: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco WS&D 2016

Addendum No. 1 WEBER ES PARTIAL FLOOR PLAN

03/16/2016

15137.00

AD01-A6

ART

28

MUSIC

29

ERIA

FM

OFFICEART

28

MUSIC

29

ERIA

FM

OFFICE

114

114

F130

F145204

Page 89: SECTION 00 9111...A. REVISION: Detail 1, Jeffco Open School First Floor Plan, revise keynotes at doors A103A and A103B from 103 to 113 per attached sketch AD01: A5. ACM was not detected

Jeffco WS&D 2016

Addendum No. 1 WITT ES PARTIAL FLOOR PLAN

03/16/2016

15137.00

AD01-A7

5

CLINIC

H106 ACTIVITY

KINDERGARTEN

H116

WORK RM

H103

SE

CR

ET

AR

YH

102RECEPTION

H101

CORR

S104

W RR

G112

OFFICE

G110

ALCOVE

G109 M RR

G111

VEST

S106

VEST S103C

VEST S103B

CORR

S103

STOR

G108STOR

G107

VEST

S103AGYMRAMP

S103

CUST

G102

T

2D

SHOWER

G103

CE

04

GYM

G101

CAFETERIA

G106KITCHEN

G121

PANTRY

G122

CUST

G120

PA

SS

G118

OUTSIDESTOR

G119

OFFICE

G116

ALCOVE

G115

VEST

G114

SING

05

EC

34

114

112

G119

DA