/01 01 MiNi TM MiNi TM Strong Solution for Narrow Ridge. Volume MiNi C4.0

Upload: others

Post on 31-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • /0101MiNiTM

    MiNiTMStrong Solution for Narrow Ridge.

    Volume MiNi C4.0

  • 02

    MiNiTM Features 04

    MiNiTM Fixture Product 05- Fixture 05- Cover Screw & Healing Abutment 06

    MiNiTM Abutment Options - Fixture level prosthesis 07- Overdenture prosthesis / Meg-Rhein System 12

    MiNiTM Surgical Kit 16- Fixture Length and Drill Marking 18- Surgical Drilling Sequence 19

    Extra Option Product - i-Gen 20- 911kit 21

    Clinical Report 26

    ➲ Contents

    MiNiTM

  • /0302MiNiTM

    ➲ MiNiTM

    Ca2+ ions are incorporated onto the S-L-A surface through a unique hydrothermal treatment. This treated surface activates the osteoblasts in living organisms creat-ing a secure bone matrix layer that is combined with PO43- ions. XPEED provides a fast and secure osteointegration over the entire surface of the fixture.

    MiNiTM was designed for your convenience with better reliability.

  • 04

    ➲ MiNiTM Features

    (unit : mm)

    Mechanical test using universal testing machine in accordance with ISO 14801,-R&D center in MegaGen Implant Co.,Ltd.(2013)-

    Parallelwall thickness

    MiNiTMØ3

    MiNiTMØ3.25

    Company AØ3

    A 0.28 0.47 0.34

    B 0.31 0.42 0.44

    11˚connection

    M1.4Abutment Screw

    XPEEDSurface treatment

    1.7mm Hex

    Knife thread

    MiNiTM, but mighty- When compared with the company A, MiNiTM internal fixture Ø3.0 has similar compressive strength, but Ø3.25 fixture showed much higher value of strength on the thin wall area of the fixture.

    Company AØ3.0

    Company AØ3.0

    MiNiTM Ø3.0

    MiNiTMØ3.0

    MiNiTMØ3.25

    MiNiTMØ3.25

    Ø3.0Ø3.0 Ø3.4

    676.6

    Load

    (N)

    500

    550

    650

    600

    700

    750

    800

    657.1

    784.4

    AA A

    B BB

    [Compressive Strength]

    [Wall Thickness]

  • /0504MiNiTM

    ➲ MiNiTM Fixture Product 1) FixtureØ3.0- Cover Screw included

    Ø3.25- Cover Screw included

    Ø3.0

    8.5 MIIF3008C

    10.0 MIIF3010C

    11.5 MIIF3011C

    13.0 MIIF3013C

    15.0 MIIF3015C

    Ø3.25

    8.5 MIIF3308C

    10.0 MIIF3310C

    11.5 MIIF3311C

    13.0 MIIF3313C

    15.0 MIIF3315C

    L

    L

    Length(mm)

    Length(mm)

    Diameter

    Diameter

    Ref.C

    Ref.C

    Ø3.25

    Ø3.4

    Ø3.0

    • PlatformdiameterofØ3.25fixtureiswiderthanreference diameter.

  • 06

    ➲ MiNiTM Fixture Product 2) Cover Screw & Healing Abutment

    • Recommendedtorque-Manual(5~10N∙cm)

    Healing Abutment

    Cover Screw

    Ø3

    1.0 MIHA3025

    1.5 MIHA3030

    2.5 MIHA3040

    3.5 MIHA3050

    4.5 MIHA3060

    Ø3.5

    1.0 MIHA3525

    1.5 MIHA3530

    2.5 MIHA3540

    3.5 MIHA3550

    4.5 MIHA3560

    Cuff Height(mm)

    Cuff Height(mm)

    ProfileDiameter

    ProfileDiameter

    Ref.C

    Ref.C

    • Recommendedtorque-Manual(5~10N∙cm)

    0.5 MICS2505

    Height(mm) Ref.C0.5

    Top view

    C.H

    C.H

  • /0706MiNiTM

    ➲ MiNiTM Abutment Options 1) Fixture level prosthesis

    EZ Post

    TemporaryAbutment

    Impression Coping(Transfer)

    Impression Coping(Pick-up)

    Cover Screw

    Lab Analog

    Closed tray Open tray

    Milling Abutment

    FuseAbutment

    Healing Abutment

    Angled Abutment

    Ø3.

    0

    Ø3.

    25

  • 08

    ➲ MiNiTM Abutment Options 1) Fixture level prosthesis

    EZ Post- Abutment Screw(MIAS14) included

    Ø3.5 5.0

    1.0 MIEP3505HT

    1.5 MIEP3515HT

    2.5 MIEP3525HT

    3.5 MIEP3535HT

    4.5 MIEP3545HT

    Ø3.5 7.0

    1.0 MIEP3507HT

    1.5 MIEP3517HT

    2.5 MIEP3527HT

    3.5 MIEP3537HT

    4.5 MIEP3547HT

    Ø3.5 9.0

    1.0 MIEP3509HT

    1.5 MIEP3519HT

    2.5 MIEP3529HT

    3.5 MIEP3539HT

    4.5 MIEP3549HT

    ProfileDiameter

    ProfileDiameter

    ProfileDiameter

    PostHeight(mm)

    PostHeight(mm)

    PostHeight(mm)

    Cuff Height(mm)

    Cuff Height(mm)

    Cuff Height(mm)

    Ref.C

    Ref.C

    Ref.C

    C.H

    C.H

    C.H

    5

    7

    9

    Ø3.5

    Ø3.5

    Ø3.5

    • Recommendedtorque-15N∙cm

  • /0908MiNiTM

    Ø3.5

    2.5

    Hex

    15°

    MIAA3215HT

    3.5 MIAA3315HT

    4.5 MIAA3415HT

    2.5

    Hex-E

    MIAA3215ET

    3.5 MIAA3315ET

    4.5 MIAA3415ET

    Milling Abutment- Abutment Screw(MIAS14) included

    Angled Abutment- Abutment Screw(MIAS14) included

    Ø3.0 5.0

    1.0 MIMA3005HT

    1.5 MIMA3015HT

    2.5 MIMA3025HT

    3.5 MIMA3035HT

    4.5 MIMA3045HT

    Ø3.0 9.0

    1.0 MIMA3009HT

    1.5 MIMA3019HT

    2.5 MIMA3029HT

    3.5 MIMA3039HT

    4.5 MIMA3049HT

    Ø3.0 7.0

    1.0 MIMA3007HT

    1.5 MIMA3017HT

    2.5 MIMA3027HT

    3.5 MIMA3037HT

    4.5 MIMA3047HT

    ProfileDiameter

    ProfileDiameter

    ProfileDiameter

    ProfileDiameter

    Type

    PostHeight(mm)

    PostHeight(mm)

    PostHeight(mm)

    Angle

    Cuff Height(mm)

    Cuff Height(mm)

    Cuff Height(mm)

    Cuff Height(mm)

    Ref.C

    Ref.C

    Ref.C

    Ref.C

    C.H

    C.H

    C.H

    C.H C.H

    5

    7

    9

    Ø3.0

    Ø3.0

    Ø3.0

    Ø3.5 Ø3.5

    15° 15°

    Hex Hex-E• Recommendedtorque-15N∙cm

    • Recommendedtorque-15N∙cm

  • 10

    Temporary Abutment- Abutment Screw(MIAS14) included

    Fuse Abutment- Abutment Screw(MIAS14) + Fuse Cap included

    Impression Coping- Guide Pin included

    Lab Analog

    Ø5.0 Ø3.5 3.5 7.0Straight MFAP3535P

    Angled(15°) MFAA3315P

    Ø3.0 12 MITA3012HT

    Ø3.514 Transfer MIIT3516HT

    16 Pick-up MIIP3516HT

    12 MILA300H

    ProfileDiameter

    ProfileDiameter

    C.H(mm)

    P.H(mm)

    Length(mm)

    Length(mm)

    Length(mm)

    Ref.CTypeLabio-lingualMesio-distal

    Ref.C

    Ref.CType

    Ref.C

    • Recommendedtorque-10~15N∙cm

    • Recommendedtorque-10~15N∙cm

    • Guide Pin Transfer type - MIGPT16 Pick-up type - MIGPP16

    15°

    ➲ MiNiTM Abutment Options 1) Fixture level prosthesis

    Mesio-distal

    Mesio-distal

    Labio-lingual

    Labio-lingual

    12

    P.H

    C.H

    Transfer type Pick-up type

    14 16

    12

    Ø3.5 Ø3.5

    Ø3.0

  • /1110MiNiTM

    density of bone without defect. First, Any-Ridge implants were placed into the interna-tionally recognized standard bone block with more 40Ncm torque force and an abutment was connected on each implant. Instron was used to measure the force to move a fixture 100μm. The average force was 220N (22.4 kgf). Therefore, If the new temporary abut-ment can be fractured under this force, it may protect the fixture from movement or failure.

    From this experiment, we could developed a special temporary abutment which has lower fracture threshold of less than 200 N (20.4 kgf). It was named as Fuse Abutment. Also it has an anatomic profiles to make temporary prosthetics more esthetic.

    Fuse Abutment ™

    In 1992, Brunski JB. reported that an implant may have higher possibility of fibrous-inter-gration than osseo-integration between bone and implant surface when movements more than100um occurs on the fixture during os-seointegration period. (John B. Brunski, Bio-mechanical factors affecting the bone-dental implant interface. Clinical Materials, Vol. 10, 153-201) Therefore, the implant is needed to be protected not to move when immediate loading is carried out. However, it is not easy to manage loading on the fixture, even when we use a resin temporary with a titanium cyl-inder. It was thought that it’s partly because of the metal component of temporary cylin-der, which can deliver excessive forces to the fixture. This is one of the reasons which make clinicians hesitate the immediate loading pro-cedure. So it is necessary to develop a spe-cial temporary cylinder. It should be broken under the force which can lead fibrointegra-tion or failure of osseointegration to protect the fixture. and it will be preferred if it is easy to make a temporary crown on this particular temporary cylinder. We tried to measure the force causing movement of 100μm on a fix-ture which was placed securely into adequate

    Similar to acustomized abutmentfor excellent esthetics!

    Perfect margin fitnesswith a prosthetic cap

    Scalloped outline

    Various Angle :Straight 15° 25°

    S-line

    Elliptical Occlusal view like a natural tooth

    Average < 180N

    Disp

    lacem

    ent(m

    m)

    Force(N)

    Micro-movement test of implant

    Fuse Abutment

    area

    0 50

    0.1

    0.2

    0.3

    0.4

    0.5

    100 150 200 250 350 400 450 500

    D1

    D2

    D3

    D4

    300

    Com

    pres

    sive

    stre

    ngth

    (N)

    Displacement(mm)

    Compressive strength test of Fuse Abutment

    0

    50

    100

    150

    200

    250

    1 2

    Specimen 2Specimen 3Specimen 4Specimen 5

    Specimen 1

    Design concept of Fuse Abutment™

    Rationale of Fuse Abutment™

    Mesio-distal

    Labio-lingual

    Performed compressive strength test to evaluate the micro-movement for bone density using universal testing machine-R&D center in Megagen Implant Co.,Ltd.(2012)-

    Performed compressive strength test to evaluate the yield strength for Fuse Abutment using universal testing machine-R&D center in Megagen Implant Co.,Ltd.(2012)-

  • 12

    ➲ MiNiTM Abutment Options 2) Overdenture prosthesis : Meg-Rhein Overdenture System

    Retentive Cap Set

    Lab Analog

    Impression Coping

    Meg-Rhein Abutment

    Ø3.

    5

    Ø4.

    0

    Ø4.

    5

    Ø5.

    0

    Ø6.

    0

    Ø7.

    0

  • /1312MiNiTM

    ➲ MiNiTM Abutment Options 2) Overdenture prosthesis : Meg-Rhein Overdenture System

    ➲ Meg-Rhein

    ➲ Meg-Rhein Option

    Meg-Rhein Package- 1 Meg-Rhein Abutment- 1 Plastic Carrier- 1 Stainless Steel Housing- 3 Retentive Caps (Black, Yellow, Pink)

    0 MDR00

    1 MDR01

    2 MDR02

    3 MDR03

    4 MDR04

    5 MDR05

    6 MDR06

    Cuff Height (mm) Ref.C

    • Perfect compatibility with the Rhein83 from Italy.• Recommend torque : 35Ncm.

    C.H8.8

    4 Retentive Caps (Violet) 140CEV

    Ref.C

    • Violetcap(2.7kg)-Forrefill(4ea/pack)

    2 Stainless Steel Housings 141CAE

    Ref.C

    • 2ea/pack

    4 Retentive Caps (White) 140CET

    Ref.C

    • Whitecap(1.8kg)-Forrefill(4ea/pack)

  • 14

    ➲ Meg-Rhein Option

    Insertion Tool

    Removal Tool

    Stainless Impression Coping (Pick up)

    Lab Analog

    091EC

    085IAC

    044CAIN

    PLA

    Ref.C

    Ref.C

    Ref.C

    Ref.C

    • 2ea/pack• Italy - Rhein83 products.• For accurate (pick-up type) impression.• Metal with groove design to prevent from swaying.

    • To make denture model.

    5.5

    Removal Tool

    2 Stainless Steel Housings

    Plastic Carrier

    141CAE

    141CAE

    Ref.C

    Ref.C

    • 2ea/pack

    • 2ea/pack

    8.8

    83

    90

    40

  • /1514MiNiTM

    Overdenture System

    Meg-Rhein Package

    Advantage

    *Smaller & more convenient than others, with proven Italian technology.

    Product K & L

    Product P

    Meg-Rhein

    4.4mm

    2.1mm

    2.25mm

    2.3mm

    5.5mm

    5.2mm

    30º

    Violet(2.7kg)

    White(1.8kg)

    Pink(1.2kg)

    Yellow(0.6kg)

    * Seperate purchase available upon request

    1. Small & Easy-to-use Housing System

    2. Tilting Angle & Various Retentive Caps of the Meg-Rhein

    3. Low Reduction Rate & Uniform Variance of Retentive Force

    * A plastic carrier can be used as an impression coping.

    Stainless Steel

    Housing

    Black Cap

    Yellow Cap

    Pink Cap

    Meg-Rhein Abutment

    with a Plastic Carrier

    100

    80

    60

    40

    20

    0Meg-Rhein Product K

    Before After (1,000cycles)

    Product L Product P

    Rete

    ntiv

    e fo

    rce

    (kg) 3

    2

    1

    01,000 Cycles

    R2=0.85

    27%

    7349%

    51

    38%

    62

    37%

    63

    R2(Coefficient of determination) becomes more reliable when it is close to “1”.

  • 16

    ➲ MiNiTM Surgical Kit

    MiNi

    AnyOne Surgical Kit (KAOIN 3003)

    AnyRidge Surgical Kit (KARIN 3003)

    Shaping Drill

    Handpiece Connector

    Ratchet Connector

    The instrument of MiNi Internal system is contained in AnyRidge & AnyOne surgical kit.

    ※ Our customers can experience MiNi internal system at any time by purchasing of the instrument even for the customers currently not in use of AnyRidge & AnyOne Internal system.

    DIRECTION INDICATOR

    Ø3.3 / Ø4.8

    TORQUE WRENCH

    PATH FINDER

    DRILL EXT.

    REMOVALDRIVER

    HANDDRIVER

    Ø4.

    0

    Ø4.

    5

    Ø5.

    0

    Ø5.

    5

    Ø6.

    0

    Ø6.

    5

    Ø7.

    0

    Ø7.

    5

    Ø8.

    0

    Ø3.

    5

    LANCEDRILL

    Ø2.0 Ø3.3 Ø3.8 Ø4.3 Ø4.8 Ø5.4 Ø5.9

    Ø3.3 / Ø3.8 CORTICALBONE DRILL

    Ø4.1 / Ø4.4 Ø5.7 / Ø6.0

    Ø3.

    0

    Ø3.

    25

    15.013.011.510.08.57.0

    Ø2.0 / Ø2.9

    OPTION

    Ø2.5 Ø2.8

    S

    L

    HANDPIECECONNECTOR

    RATCHETCONNECTOR

  • /1716MiNiTM

    ➲ Surgical Components

    Handpiece Connector

    Ratchet Connector

    Shaping Drill

    1.7Short HCS17

    Long HCL17

    1.7Short RCS17

    Long RCL17

    Ø2.533

    SD2518S

    Ø2.8 SD2818S

    Length(mm)

    Length(mm)

    Hex Size(mm)

    Hex Size(mm)

    Diameter

    Ref.CType

    Ref.C

    Ref.C

  • 18

    ➲ Fixture Length and Drill Marking

    ➲ Surgical Drilling Sequence

    Actual drilling depth 10.5mm= 0.5mm subcrestal + 9.5mm actual fixture length + 0.5mm Y value

    Actual drilling depth 10.6mm = 0.5mm subcrestal + 9.5mm actual fixture length + 0.6mm Y value

    Ø3.

    0

    Ø3.

    259.

    5mm

    10.0

    mm

    0.5mm

    InitialDrill Ø2.0 Ø2.5

    9.5m

    m

    10.0

    mm

    0.5mm

    InitialDrill Ø2.0 Ø2.5 Ø2.8

    3mm

    0.5mm

    The platform line of the HandpieceConnector or the Ratchet Connectormust be flush with the fixture platform.

    WhenusingtheRatchetWrench,donotuseanexcessivetorqueasitcanleadtoafailureofinternalstructuraldamagetothefixtures.Itisnotrecommendedtoexceedthemaximumtorqueof75N·cm.

    The actual lengths of MiNiTM internal fixture is 0.5mm shorter than the depth markings of a Shaping Drill.Therefore, the fixture will be placed 0.5mm under the crest naturally.

    Actual drilling depth 10.5mm = 0.5mm subcrestal + 9.5mm actual fixture length + 0.5mm Y value* Fixture Ø3.0 (Y value = 0.5mm), Ø3.25 (Y value = 0.6mm)

    0.5mm Subcrestal

    Fixture length 9.5mm

    Y value 0.5mm

    15.0mm

    13.0mm11.5mm10.0mm8.5mm

    0.5mm

    8.0m

    m

    9.5m

    m

    11.0

    mm

    12.5

    mm

    14.5

    mm

    Ø3.

    0

  • /1918MiNiTM

    A1 4 9 11 4.5 - - IG1W4509

    A2 4 10 11 5.5 - - IG1W5510

    A3 4 11 11 6.5 - - IG1W6511

    B1 5 9 11 4.5 - - IG2W0918

    B2 6.5 11 11 5.5 - - IG2W1120

    B3 9 13 11 6 - - IG2W1323

    C1 5 9 11 4.5 6 4.25 IG3W0921

    C2 6.5 11 11 5.5 8 4.25 IG3W1125

    C3 9 13 11 6 10 9 IG3W1328

    ➲ Extra Option Products 1) i-Gen

    M1.4

    1.5 IA1415

    2.0 IA1420

    3.0 IA1430

    Hex 1.2 1.0 ICS3510

    i-Gen Screw

    i-Gen Membrane

    i-Gen Cover Screw-UseHandDriver(1.2Hex)

    Type Cuff Height(mm) Ref.C

    Type Height (mm) Ref.C

    PL

    Proximal Length

    BWBuccal width

    BLBuccal Length

    BDBuccal

    Distance

    LWLingual width

    LLLingual Length

    Ref.CType

    A1 B1 C1

    A2 B2 C2

    A3 B3 C3

    C.H

    1.0

    BW LW

    BL

    BDLL

    PL

    • MegaGen (MiNi)• Astra (Osseospeed) : Diameter Ø3.5S• Dentsply-Frident (XiVE) : Diameter Ø3.0

  • 20

    i-Gen

    Design concept of i-Gen

    Ideal + Regeneration membrane ⇒ i-Gen membrane

    >2.5mm horizontal extensionneeded to make >2mm labial bone after remodeling.Lingual Extension

    should be considered for a large defect.

    Need to have at least1mm of space above the platform of a fixture: Make this space with a pre-existing abutment, eg, i-Gen Screw.

    >100°blunt anglewith bevel should be made to avoid soft tissue irritation.

    sh r inkage w i l l occur after removal of mem-brane.

    should be adapted to the bone.

    0.5~1.0mm

    Apical skirt

    Ideal regeneration line

    Compatible with other implant brands now!

    ≥2mm

    1. Place an implant into the recipient site.2. Connect a i-Gen Screw to the implant and

    bone grafting. Usually 1 mm cuff height is good enough for vertical space, but 2 or 3 mm cuff height of i-Gen Screw can be cho-sen according to situation. The amount of graft material should be enough to fill the space between i-Gen and the fixture.

    3. Selection of i-Gen and placement. Accord-ing to the size and shape of bone defect, an i-Gen can be chosen from 9 different shapes. Match the hole of i-Gen with the screw hole of i-Gen screw.

    4. Fixate i-Gen with a i-Gen Screw. Choose a i-Gen Cover Screw or Flat Healing Abut-ment to fix i-Gen membrane depend on the need of one or two stage surgery. And tight adaptation of soft tissue flap is recom-mended.

    * Flat Healing Abutment : P40

    1

    3

    2

    4

  • /2120MiNiTM

    Hex

    - 911 Fixture Removal kit (KPSFS3000)

    Hex

    Hex

    2) 911 kit (KPSCS3000)

  • 22

    ➲ 911kit Components

    FixtureRemover

    TorxDriver

    Torque Wrench

    FixtureRemoverScrew

    Ø3.0~Ø3.615 FSS3035

    20 FSL3035

    Ø3.7~Ø4.615 FSS3540

    20 FSL3540

    Ø4.7~Ø5.615 FSS4555

    20 FSL4555

    Ø5.7~Ø7.015 FSS6080

    20 FSL6080

    Applied Fixture Diameter Length(mm) Ref.C

    M1.4(MiNi) FSS14

    M1.6(EZ Plus, ExFeel Ø3.3) FSS16

    M1.8(AnyRidge) FSS18

    M2.0(AnyOne, Mega Fix, EZ Plus, ExFeel)) FSS20

    M2.5(Rescue) FSS25

    Applied Fixture Thread Ref.C

    5 TD05

    15 TD15

    20 TD20

    300Ncm TW500

    70Ncm TW70

    Length (mm) Ref.C

    Type Ref.C

    • Toremovethefixture.WhenselectingaFixtureRe-mover,considertheouterdiameterofaFixture.IncaseofAnyRidgeFixturethatthethreadisformedunderplatform,selectaFixtureRemoveraccordingto platform size

    • ToconnectfixtureandFixtureRemover.• Recommended tightening torque FSS14, FSS16 :

    40~50 Ncm FSS18, FSS20, FSS25 : 70~80 Ncm.

    • ToconnectfixturetoFixtureRemoverScrew

    • TW500:Tochecktorqueforcewhenremovingfixture.• TW70:TochecktorqueforcewhentighteningFixture

    Remover Screw.

    L

    L

  • /2322MiNiTM

    Abutment Remover

    Screw Remover

    Screw RemoverGuide

    Internal

    10 SSIG10

    16 SSIG16

    22 SSIG22

    22 SSIG22W

    External

    Hex 2.4 SSEG24

    Hex 2.7 SSEG27

    Hex 3.3 SSEG33

    Applied Fixture Diameter Length(mm) Ref.C

    22 ASS

    27 ASL

    30 SSS

    45 SSL

    Length (mm) Ref.C

    Length (mm) Ref.C

    Screw RemoverGuide Holder SSGH

    Ref.C

    HexRemover22 HSS

    27 HSL

    Length (mm) Ref.C

    • On fractured abutment.• Use screw size M1.8 & M2.0.

    • To remove fractured screw. • Use screw size M1.8 & M2.0.

    • To secure the Screw Remover from moving side to side when removing the screw.

    • Tool to supporting the Screw Remover Guide.

    • Toremovehex-damagedAbutmentScrew,CoverScrew or Healing Abutment.

    L

    L

    L

  • 24

    Fixture Remover

    Abutment Remover

    ➲ Fixture Remover Screw: Single use only➲ Do not use in case of a gap in Fixture Remover

    ➲ Can use for abutments that use M1.8 & M2.0 screws.➲ Cannot use for abutment that use M1.6 and M2.5

    Remove the prosthesis of the fi xture to be removed, and the surrounding bone.

    Insert the Abutment Remover in the fractured abutment hole.

    Select a Fixture Capture Screw of the same size as the fixture internal screw. Use the Torx Driver to turn the screw clock-wise (40Ncm~70Ncm) to place in the fixture. (Use of torque less than 40Ncm for M1.6, and 60Ncm for other products may lead to loosening)

    Select a Fixture Remover that fits the fixture diameter. Turn the fixed Fixture Remover Screw counterclockwise until it touches the fixture. (For a torque of greater than 300Ncm, it is rec-ommended to use a Trephine bur)

    Fixture and Fixture Remover are tightly connected as rising force and descending force are com-bined. (Suction is needed; debris may happen on removal of a fi- xture)

    Using Torque Wrench, turn coun-terclockwise and pull out fixture and Fixture Remover. (No more than maximum torque per fixture)

    Removed fixture can be pulled out, turning Fixture Remover and fixture clockwise, holding onto vice plier.

    Use the Ratchet Wrench to turn clockwise in order to join the abutment and the Abut-ment Remover as one body. (Ratchet Wrench is included in surgical kit)

    Move the Abutment Remover sideways while pulling up to remove it. (Use of excessive force may traumatize the fi xture or the bone)

    Secure the separated abut-ment in a vice or vice pliers. Use the Ratchet Wrench to turn counterclockwise to sep-arate the abutment with the Abutment Remover.

    911kit

  • /2524MiNiTM

    Screw Remover

    Hex Remover

    Remove the broken Abutment Screw and the abutment.

    In case Abutment Screw, Cover Screw or Healing Abut-ment’s hex is fractured.

    Select the correct Screw Re-mover Guide that fits the fixture connection to join.

    Secure the Screw Remover Guide and insert the Screw Holder in the Screw Remover Guide hole.

    Push the Screw Remover down- wards while rotating counter clockwise to separate it from the fixture internal screw. (rpm:30~50, Torque : 30Ncm)

    Remove the pieces of broken screw from the fixture internal screw using forceps.

    When separating the holder from the guide, push in the direction of the arrow to separate.

    Use the Ratchet Wrench to turn counterclockwise to join the abutment with the Abut-ment Remover as one body. (Use a torque of less than 40Ncm., Ratchet Wrench is included in surgical kit.)

    Place the removed abutment in the vice. Use the Ratchet Wrench to turn clockwise to separate the abutment with the Hex Remover.

  • 26

    ➲ Clinical Report

    Fig 1. Preoperative panoramic radiograph and intraoral photos. The ridge was atrophied due to long-term absence of teeth.

    Fig 3. Two Ø3.0 x 15.0 mm MiNiTM internal fix-tures were placed with excellent stability. GBR was not required.

    Fig 5. Flap was sutured and EZ Posts were milled for the better path.

    Fig 7. Clinical photo and intraoral radiograph at once after surgery.

    Fig 2. Flap was elevated and two osteotomy sock-ets were made for 3.0mm MiNiTM internal fixtures. There was enough bone left in labio-lingual area for slim fixture.

    Fig 4. Two EZ Posts were connected to make temporary prosthetics for immediate provisionali-zation.

    Fig 6. Provisional restoration was made at the chair side. Due to the smaller diameter of fixture and abutment, the prosthetics could have a nice emergence profile.

    Fig 8. Clinical photo and in-traoral radiograph 1 month after surgery.

    Fig 9. Clinical photo and intraoral radiograph after final restoration.

  • 26

    Gangnam Office 5F MegaGen Tower, 607 Seolleung-ro, Gangnam-gu, Seoul, Korea T. +82-1566-2338 Head Office & Factory 472 Hanjanggun-ro, Jain-myeon, Gyeongsan, Gyeongbuk, Korea T. +82-1544-2285

    www.imegagen.com