statistical yearbook 2011...entso-e statistical yearbook 2011 5 country company abbreviation at...

136
European Network of Transmission System Operators for Electricity Statistical Yearbook 2011

Upload: others

Post on 17-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

European Network ofTransmission System Operators

for Electricity

Statistical Yearbook 2011

Page 2: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 3: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 3

Introduction and common information

ENTSO-E Net generation, exchanges and consumption 2011 ................................................................... 4

Generation- Overview ENTSO-E in figures 2011 - Electricity system data of member TSOs' countries ............................10- Net electricity generation and its structure ...................................................................................................12- Other renewable generation including wind and solar power 2010 and 2011 .................................................13- Development of net electricity generation .....................................................................................................14

Exchanges- Physical energy flows 2011 - Graphical overview ..........................................................................................15- Physical energy flows 2011 - Detailed inside and outside flows between the countries ................................16- Development of physical exchanges on tie lines ...........................................................................................17- Monthly electricity exchanges on tie lines ....................................................................................................18- Balance of load flows at 03:00 a.m. and 11:00 a.m. on the 3rd Wednesday of each month ...........................20

Consumption- Highest and lowest hourly load value of each country 2011 ..........................................................................22- Highest and lowest load on 3rd Wednesday in 2011 ......................................................................................23

Generating capacity- Net generating capacity on 31 December 2010 and 2011 .............................................................................24- Inventory of thermal units > 10 MW as of 31 December 2011 .......................................................................25- Inventory of hydro power units > 1 MW as of 31 December 2011 ..................................................................26

Yearly values / operation and physical exchanges- Yearly values operation and physical exchanges per countries for the years 2006, 2010 and 2011 ..............27

System information- Inventory of transmission network installations as of 31 December 2011 .................................................... 105- Number of circuits < 220kV, 220 kV and over 220 kV on tie lines ............................................................... 106- Simplified diagram of the ENTSO-E tie lines of the synchronous area of ENTSO-E as of 31 December 20111 ........................................................................................................................... 109- Characteristics of the ENTSO-E tie lines as of 31 December 2011 ............................................................. 110- Unavailability of international tie lines - yearly overview 2011 ...................................................................... 121

Glossary of statistical terms ...................................................................................................................... 127

Table of contents

Page 4: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

4 ENTSO-E Statistical Yearbook 2011

Introduction and common information

Background on the ENTSO-E Statistical Yearbook 2011

The statistical yearbook 2011 covers all 41 ENTSO-E members, across 34 countries. Its purpose is to bring a wide spectrum of retrospect figures on power systems of member transmission system operators (TSOs), among which generation, consumption, cross-border exchanges and network components.

This edition, on which the ENTSO-E data expert group has been working on consolidating the collection of statistical data from all member TSOs' countries, will help you to find data more easily as links have also been added and are available on www.entsoe.eu/resources/data-portal

Activities related to harmonization of data processes, data definitions and IT tools are still ongoing with in ENTSO-E working groups, which will lead to the creation of a central database gathering all the information previously available through former associations.

What is ENTSO-E?

ENTSO-E is the European Network of Transmission System Operators for Electricity. The association is representing 41 transmission System Operators (TSOs) across 34 countries.

With important tasks given by Regulation (EC) 714/2009, ENTSO-E's role is to enhance cooperation between TSOs across Europe in order to assist in the development of a pan-European electricity transmission network in line with European Union energy goals. Its specific aims are to:

- Ensure the secure reliable operation of the increasingly complex network;

- Facilitate cross-border network development and the integration of new renewable sources of energy;

- Enhance the creation of the Internal Electricity Market (IEM) through standardized market integration and transparency procedures

ENTSO-E is responsible for creating common tools (network codes), a Ten-Year Network Development plan, recommendations for the coordination of technical cooperation between, TSOs within the EU, and annual outlooks for summer and winter electricity generation.

Principles of data handling, Statistical Data Correspondents and Data Expert Group

Data Expert Group, Statistical Data Correspondents and the ENTSO-E Secretariat are in charge of statistical data in terms of methodological development, data processing and the production of various reports including this Statistical Yearbook.

Statistical data is regularly collected by Statistical Data Correspondents of member TSOs' countries. The data is stored in the ENTSO-E statistical database, which can be accessed directly through web based queries or via reports published on the website www.entsoe.eu

The figures indicated for various countries may differ from some other national statistics published because ENTSO-E statistics only describe that part of the electricity supply system, which concerns interconnected system operation.

Consequently, this data may not represent the entire interconnected system in some countries.A corresponding representativeness factor is provided wherever necessary.

Page 5: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 5

Country Company Abbreviation

AT Austrian Power Grid AG APGVorarlberger Übertragungsnetz GmbH VUEN(until January 2012 VKW-Netz AG)

BA Nezavisni operator sustava u Bosni i Hercegovini NOS BiHBE Elia System Operator SA EliaBG Electroenergien Sistemen Operator EAD ESOCH swissgrid ag swissgridCY Cyprus Transmission System Operator Cyprus TSOCZ CEPS a.s. CEPSDE Amprion GmbH Amprion

TenneT TSO GmbH Tennet DETransnetBW GmbH TransnetBW(until February 2012 EnBW Transportnetze AG)50 Hertz Transmission GmbH 50 Hertz

DK Energinet.dk Independent Public Enterprice Energinet.dk IPCEE Elering AS Elering ASES Red Eléctrica de España S.A. REEFI Fingrid Oyj FingridFR Réseau de Transport d’Electricité RTEGB National Grid Electricity Transmission plc National Grid

System Operator for Northern Ireland Ltd SONI LtdScottish Hydro Electric Transmission Limited SHETLScottish Power Transmission plc SP Transmission

GR Independent Power Transmission Operator S.A. IPTO SA(until January 2012 Helenic Transmission System Operator S.A.)

HR HEP-Operator prijenosnog sustava d.o.o. HEP-OPSHU MAVIR Magyar Villamosenergia-ipari Átviteli Rends-

zerirányító Zártköruen Muködo Részvénytársaság MAVIR ZRt.IE EirGrid plc EirGridIS Landsnet hf LandsnetIT Terna - Rete Elettrica Nazionale SpA TernaLT LITGRID AB LITGRID ABLU Creos Luxembourg S.A. Creos LuxembourgLV AS Augstsprieguma tÏkls Augstsprieguma tÏklsME Crnogorski elektroprenosni sistem AD CGES ADMK Macedonian Transmission System Operator AD MEPSONL TenneT TSO B.V. TenneT NLNO Statnett SF StatnettPL PSE Operator S.A. PSE OperatorPT Rede Eléctrica Nacional, S.A. RENRO C.N. Transelectrica S.A. TranselectricaRS JP Srbije EMSSE Affärsverket Svenska Kraftnät Svenska KraftnätSI Elektro Slovenija d.o.o. ELESSK Slovenska elektrizacna prenosova sustava, a.s. SEPS

ENTSO-E member companies

Page 6: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

6 ENTSO-E Statistical Yearbook 2011

The following Statistical Data Correspondents provided the data and can give additional information onthe contents and interpretation of the statistics:

Country Name Company E-Mail

AT E.Reittinger-Hubmer Austrian Power Grid [email protected]

BA c NOS BiH a

BE D.Couckuyt Elia [email protected] A.Georgiev ESO [email protected] R.Bissig swissgrid ag [email protected]

CY G.Christofi Cyprus TSO [email protected] Z.Fucik CEPS a.s. [email protected] B.Wegner BDEW [email protected] C.Rasch Energinet.dk [email protected]

EE K.Ainsaar Elering AS [email protected] V Garcia REE s

FI H.Maula Fingrid Oyj [email protected] E.Pharabod RTE [email protected]

GB L.Chennells National Grid [email protected] A.Anagnostou IPTO SA [email protected] V.Grujic HEP-OPS [email protected]

HU L.Galambos MAVIR ZRt. [email protected]

IE P.Carroll EirGrid plc [email protected]

IS R.Stefánsson Landsnet hf [email protected] D.Camuffo Terna S.p.A. [email protected]

LT R.Platakiene LITGRID AB [email protected]

LU D.Rendulic Creos Luxembourg S.A. [email protected]

LV A.Eglitis AS Augstsprieguma tÏkls [email protected]

ME D.Svrkota CGES AD [email protected] I.Netkova MEPSO i [email protected]

NI H.Magorrian SONI [email protected] R.Kok TenneT TSO B.V. [email protected]

NO L.Christiansen Statnett SF [email protected] L. i PSE Operator S.A. pse-operator.plPT J.Milheiro Batista REN [email protected] C.Radoi CN Transelectrica S.A. [email protected] S.Vujnovic JP EMS [email protected]

SE B.Falt Svenska Kraftnät [email protected] D.Novakovic ELES [email protected]

SK S.Dudasik SEPS a.s. [email protected]

Statistical Data Correspondents

Page 7: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

European Network ofTransmission System Operators

for Electricity

1 ENTSO-E Net generation, exchanges

and consumption 2011

2 Yearly values / operation and

physical exchanges

3 System information

4 Glossary of statistical terms

Page 8: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 9: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 9

ENTSO-E Net generation, exchanges and consumption 2011

Generation

Overview ENTSO-E in figures 2011 - Electricity system data of member TSOs' countries .............................. 10

Net electricity generation and its structure .....................................................................................................12

Other renewable generation including wind and solar power 2010 and 2011 ....................................................13

Development of net electricity generation ........................................................................................................14

Exchanges

Physical energy flows 2011 - Graphical overview............................................................................................. 15

Physical energy flows 2011 - Detailed inside and outside flows between the countries ...................................16

Development of physical exchanges on tie lines ............................................................................................. 17

Monthly electricity exchanges on tie lines ...................................................................................................... 18

Balance of load flows at 03:00 a.m. and 11:00 a.m.on the 3rd Wednesday of each month ............................... 20

Consumption

Annual maximum load in each country 2011 ..................................................................................................22

Highest and lowest load in each country on 3rd Wednesday in 2011 ...............................................................23

Generation capacity

Net generating capacity on 31 December 2010 and 2011 ............................................................................... 24

Inventory of thermal units > 10 MW as of 31 December 2011 .........................................................................25

Inventory of hydro power units > 1MW as of 31 December 2011 .....................................................................26

Page 10: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

10 ENTSO-E Statistical Yearbook 2011

Overview ENTSO-E in figures 2011 - Electricity system data of member TSOs' countries

Countries AT BA BE BG CH CY CZ DE DK EE

Net generation "All values are calculated to represent 100% of the national values"

Nuclear power GWh 0 0 45943 15172 25560 0 26709 101458 0 0

Fossil fuels GWh 23007 9404 28996 25889 2107 4833 48998 350456 21811 10271

Hydro power GWh 33663 4290 1410 3542 33795 0 2821 19853 19 33

hWGnoitareneg ten elbawener rehtO 0 0 9279 540 1419 115 2500 86123 11309 1085

- of which wind GWh 0 0 2307 540 60 115 384 44641 8938 364

- of which solar GWh 0 0 1493 0 0 0 2115 18341 0 0

Non-identifiable GWh 8730 0 0 0 0 0 0 0 0 0

Total net generation GWh 65400 13694 85628 45143 62881 4948 81028 557890 33139 11389

Consumption "All values are calculated to represent 100% of the national values"

hWGnoitpmusnoC 68567 12186 86536 33233 64439 4948 63040 544267 34458 7827

4,2-4,3-6,0-1,1-8,5-20,0-1,51,4-8,34,0%)0102 htiw derapmoc( noitairaV

Transmision network losses percentage consumption %

Net generation capacity as of 31 December 2011

"All values are identical with the national values and their representativity"

NGC Nuclear MW 0 0 5926 2080 3278 0 3692 12048 0 0

NGC Fossil fuels MW 7425 1506 8539 6400 388 973 10938 66967 7486 2283

NGC Hydro power MW 12919 1971 1420 3150 13723 0 2161 9209 10 4

NGC Renewable ernergy sources MW 1054 0 4142 770 508 102 2190 53532 3967 254

- of which wind MW 1017 0 1056 550 42 102 219 28254 3950 184

- of which solar MW 0 0 1901 220 111 0 1971 22306 17 0

NGC Other sources MW 0 0 0 0 205 0 0 3263 44 0

145270511910541189815701201810042172002774389312WMlatoT CGN

0010013900100100199001001001% seulav eht fo ytivitatneserpeR

32

4

1

Countries PL PT RO RS SE SI SK ENTSO-E

Net generation "All values are calculated to represent 100% of the national values"

Nuclear power GWh 0 0 10796 0 58023 5900 14379 885586Fossil fuels GWh 140894 24732 30099 32104 5359 4602 6331 1625944Hydro power GWh 2647 11825 14670 9162 65783 3362 4007 511852

hWGnoitareneg ten elbawener rehtO 8069 11866 1403 0 17256 0 863 312917 - of which wind GWh 2745 9002 1218 0 6070 0 0 175184

70300002620ralos hcihw fo - 45649Non-identifiable GWh 0 0 0 0 0 0 968 11145Total net generation GWh 151610 48423 56968 41266 146421 13864 26548 3347445

Consumption "All values are calculated to represent 100% of the national values"

hWGnoitpmusnoC 145720 50499 54916 40174 139222 12558 26780 3311650

5,05,26,5-6,19,24,3-5,1%)0102 htiw derapmoc( noitairaV -1,9Transmision network losses percentage consumption % 1,6

Net generation capacity as of 31 December 2011

"All values are identical with the national values and their representativity"

NGC Nuclear MW 0 0 1300 0 9363 696 1940 126447NGC Fossil fuels MW 30117 8779 8901 5478 4793 1282 2896 447174NGC Hydro power MW 2341 5392 6144 2888 16197 1063 2478 196758NGC Renewable ernergy sources MW 2209 4855 1030 0 6094 0 753 152948- of which wind MW 2059 4081 1006 0 2899 0 3 90134- of which solar MW 1 155 0 0 0 0 507 47636NGC Other sources MW 0 0 0 0 0 0 85 4984

25181403744636638573716209176643WMlatoT CGN 92831100100100100100179001% seulav eht fo ytivitatneserpeR

7,8 9

Page 11: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 11

Overview ENTSO-E in figures 2011 - Electricity system data of member TSOs' countries

1 The reported figures are best estimates based on actual measurements and extrapolations.

2 Calculations of net generation and consumption based on the ENTSO-E database differ from the official values from theSwiss Federal Office of Energy.

3 The reported figures are best estimates based on actual inquiries, measurements and extrapolations.

4 Electricity generation and consumption also comprise shares of generation from industry’s own power stations and feed-infrom private generators (total of 12 monthly values). The part of net electricity generation relevant to primary control poweramounts to 527,581 TWh.

5 Yearly values with the country code GB represents the sum of England, Scotland and Wales.

6 Yearly values with the country code NI represents the data GB Northern Ireland.

7 Operational data

8 Other renewable includes energy from biomass co-firing in conventional thermal units.

9 Calculated sum of the ENTSO-E member TSO's countries.

ES FI FR GB GR HR HU IE IS IT LT LU LV ME MK NI NL NO

55050 22266 421118 64550 0 0 14743 0 0 0 0 0 0 0 0 0 3919 0

121327 24167 51505 237151 42431 5161 16755 20417 8 218457 2752 2318 2885 1446 4858 6636 93002 4776

32173 12279 50267 7484 4254 4583 215 679 12743 47202 1049 1127 2870 1186 1469 7 0 121383

55594 10989 20059 19104 3379 217 1786 4359 4402 25758 620 216 183 0 0 1063 12104 1257

41661 482 12075 19104 2594 182 601 4359 0 9776 472 64 72 0 0 1005 5096 1257

9597 0 2415 0 441 0 0 0 0 10670 0 8 0 0 0 0 0 0

341 692 0 0 0 0 0 177 0 0 0 0 219 0 0 18 0 0

264485 70393 542950 328289 50064 9961 33499 25632 17153 291417 4421 3661 6157 2632 6327 7724 109025 127416

254990 84244 479242 329115 52915 17498 40142 26122 17153 334640 10362 6558 7264 4183 8986 9009 117837 122020

-2,2 -0,1 -6,7 -2,0 -1,2 -0,6 3,0 -3,4 2,8 1,3 0,8 -2,0 -0,7 3,3 7,3 -1,9 1,2 -6,4

7525 2676 63130 10397 0 0 1892 0 0 0 0 0 0 0 0 0 504 0

43659 8978 27789 61984 9614 1787 6860 6132 52 76287 2544 499 859 220 1157 2335 20137 1166

19081 3157 25405 3876 3223 2110 50 508 1860 21737 876 1134 1556 660 503 4 38 30164

26639 2254 10138 3355 1936 118 695 1615 661 20419 252 91 30 0 0 419 2439 450

20729 197 6639 3355 1363 118 325 1615 0 6918 202 41 30 0 0 405 2340 450

4916 0 2228 0 439 0 0 0 0 12773 0 40 0 0 0 0 51 0

0 44 0 45 0 0 0 242 0 0 0 16 21 0 0 7 1012 0

96904 17109 126462 79657 14773 4015 9497 8497 2573 118443 3672 1740 2466 880 1660 2765 24130 31780

100 100 100 90 100 100 100 100 100 100 100 100 100 100 100 100 100 100

5 6

Page 12: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

12 ENTSO-E Statistical Yearbook 2011

Net electricity generation1 and its structure

48,6%

26,5%

9,3%

15,3%

ENTSO-E

0,3%

Share of energy produced of each member TSOs' country 2011 in %( Based on the net generation values as of the table on page 10 and 11 )

GWh

Other renewable generation 312917(wind, solar, geothermal, waste, bio fuels)

Hydro generation 511852(storage, run of river, pumped storage)

Thermal nuclear 885586

Non-identifiable generation 11145

Fossil fuels 1625944(lignite and hard coal, gas,oil, mixed fuels, peat)

Overview generation mix as sum of the ENTSO-E member TSOs' countries

1 All values are calculated to represent 100% of the national values.

0% 20% 40% 60% 80% 100%

AT

BA

BE

BG

CH

CY

CZ

DE

DK

EE

ES

FI

FR

GB

GR

HR

HU

IE

IS

IT

LT

LU

LV

ME

MK

NI

NL

NO

PL

PT

RO

RS

SE

SI

SK

Other renewable energy sources Hydro generation Thermal nuclear Non-identifiable generation Fossil fuels

Page 13: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 13

Other renewable generation 1 including wind and solar power 2010 and 2011

0

50000

100000

150000

200000

250000

300000

350000

2009 2010 2011

GWh

month other renew of which of which other renew of which of whichexcept hydro wind solar except hydro wind solar

2010 2010 2010 2011 2011 2011GWh GWh GWh GWh GWh GWh

January 21096 12408 597 24314 14674 1124

February 21374 13079 846 25193 15465 1845

March 23875 14366 1522 26762 14855 3340

April 19249 9655 2112 25719 13214 4560

May 20297 10594 2291 26305 13225 5257

June 17129 7913 2482 23199 10835 5310

July 18408 8558 3057 23155 12231 4592

August 19198 9329 2656 23384 10569 5753

September 19301 10284 2220 24548 12411 5205

October 24091 14566 1927 28290 16418 4256

November 24599 15484 1039 25450 15205 2578

December 24373 15286 790 36598 26082 1829

Sum 2010 252990 141521 21539 Sum 2011 312917 175184 45649

1 All values are calculated to represent 100% of the national values.2 Data collection from year 2010 onwards.

Renewable generation except hydro of which wind and of which solar as sum of the ENTSO-E member TSOs' countries 1

Monthly overview of the total other renewable generation except hydro with the share of wind and solar as sum of theENTSO-E member TSOs' countries 1

year GWh

Total other renewable 2009 219566generation 2010 252990except hydro 2011 312917

2009 120489- of which wind 2010 141521

2011 175184

2009 -- of which solar2 2010 21539

2011 45649

Page 14: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

14 ENTSO-E Statistical Yearbook 2011

Development of net electrity generation 1

1 Values of detailed generation are national values; total net generation data are calculated to represent 100% of the national values.2 Before 2005, the information on other renewable energy sources was collected in a different manner. Some countries added them to fossil fuels, some considered them as the part of not represented in the figures (through the factor "representativity").

3 As of September 1995 total German values4 Including values of CZ, HU, PL, SK as of 19985 Including values of RO, BG as of 20036 Including values of DK_W as of June 20077 All yearly data from 1975 to 2008 are statistical data from the ENTSO-E Regional Group Continental Europe (former UCTE).

From year 2009 on calculated statististical data of the ENTSO-E member TSOs' countries.

Hydro power Thermal nuclear Fossil fuels Other sources 2 Total

Year hWThWThWThWThWT

3,8584,5850,059,2225791

8,9291,9665,962,1916791

8,8694,0162,282,6727791

4,32019,9564,791,6628791

3,77013,1966,0114,5729791

4,90111,2179,3314,3620891

8,52114,8760,1914,6521891

7,43115,5662,1120,8522891

0,86113,3568,8529,5523891

8,22213,7165,8430,7524891

8,87213,7953,6242,5525891

3,11316,3954,4643,3526891

1,24417,7060,3849,4627891

5,38410,7956,4159,2828891

7,82512,9666,1552,6129891

9,56516,0965,8558,2220991

0,52617,1076,9752,6421991

0,81615,9862,1952,0422991

0,03619,4669,6162,1523991

5,75617,4761,6068,8724991

1995 3 2,04718,2377,7268,562

4,14811,0772,7566,4826991

3,16811,2972,5660,2727991

1998 4 3,27127,75015,9864,482

7,82129,53010,7075,2929991

4,64224,39018,3371,5030002

0,19228,92114,4476,1331002

8,30326,78116,7571,6722002

2003 5 6,48427,50314,7874,703

2,52523,68316,8978,9134002

4,04522,891,94316,2974,2925002

9,48528,5113,45319,1084,5036002

2007 6 1,70623,3413,20414,9572,492

8,34620,0711,48318,4775,6038002

2009 7 2,63238,3221,59510,7782,045

2010 584,3 896,0 1650,1 261,3 3403,6

2011 511,0 885,6 1618,8 314,1 3347,4

0

400

800

1200

1600

2000

2400

2800

3200

3600

1975 1980 1985 1990 1995 2000 2005 2009 2011

TWh

From year 2009 on calculatedstatististical data of ENTSO-Eas sum of the member TSOs' countries.All yearly data from 1975 to 2008are statistical data from the ENTSO-ERegional Group Continental Europe(former UCTE).

Page 15: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

Physical energy flows 2011 - graphical overview in GWh

Sum of physical energy flows between ENTSO-E countries = 370786 GWh 2

Total physical energy flows = 411934 GWh 2

1 Consolidated yearly values might differ from detailed flow data from the ENTSO-E database due to ex-postconsolidation taking into account national statistical resources.

2 Calculation based on the detailed physical energy flows in the table on page 16 without exchanges ME-AL

Consolidated physicalinside and outside flowsin GWh1 :

IS

FIS ENO

D K

DE

LU

B E N L

U A

TR

CY

RU

IE

NI

GB

PT ES

CH

IT

SI

GRM K

RS

M E

B A

BG

RO

F R AT

CZ

SK

HU

H R

LV

LT

EE

PL

36003360

6718

6509

2414

5141

2906

3221

5055

1657

2633696

26

747

155 443

2734

480

127

40075936

131

28072047

628

1514

278

51384334521

7010 1533

1320

123011834

20315

1395779

11247118

2329

733

66853928

4509

14

3993

2462

2762 104

14000

25612431

14307

935

9408

18868253

45

799110055

8773581072

159235357

63

4786

3539

1821

1701276

402

23811630

3120

4590

1622316

493407

n.a.209

n.a.1489

2158

8120228 2127

3054

340

111

697

696

1176

26

2410

867 124

15

1445

5682621

2918 2823

1072124

1595

315 1144

6151

1369

1769

243

9589

ENTSO-E members

Not ENTSO-E members

3AL

2436 RU

529M D

14943772178

MA DZ TN

934

1011

212

BY2916

UA

RU

10765

edistuO edisnI

27 191 71 885AT

4 187 5 676BA

13 189 01 652BE

1 493 12 000BG

34 090 30 312CH

– –CY

10 457 27 501CZ

49 722 55 988DE

11 647 10 276E E 1 517 4 986E S 7 935 13 656F I 18 489 4 614F R 9 068 64 185G B 8 645 3 844G R 7 181 3 932H R 14 004 6 318H U 14 667 8 018I E 733 243IS – –I T 47 478 1 715LT 8 086 1 345L U 7 099 2 657LV 4 010 2 760M E 3 416 900M K 4 169 1 548N I 2 012 733N L 20 665 11 787N O 11 022 13 600P L 6 779 12 023P T 6 685 3 928R O 2 946 4 846R S 6 900 6 671SE 14 229 21 356SI 7 034 8 308SK 11 228 10 501

values in GWh

D K

3070

6169

1096

5

10

268

482590

ENTSO-E Statistical Yearbook 2011 15

59

UA-W

TR

MD529

59

1551

2494706

Page 16: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

16 ENTSO-E Statistical Yearbook 2011

Physical energy flows 2011 - Detailed inside and outside flows between the countries in GWh 1

1 D

etai

led

harm

oniz

ed v

alue

s fr

om th

e E

NT

SO

-E s

tatis

tical

dat

abas

e.2

The

info

rmat

ion

abou

t the

phy

sica

l ene

rgy

flow

s be

twee

n M

E a

nd A

L ar

e no

t ava

ilabl

e.3

In s

ynch

rone

ous

oper

atio

n w

ith E

NT

SO

-E c

ount

ries

(not

EN

TS

O-E

mem

bers

):

Alb

ania

(AL)

, Bel

arus

(BY

), M

oroc

co (M

A),

Rep

ublic

of M

olda

via

(MD

), R

ussi

a (R

U),

Rep

ublic

of T

urke

y (T

R),

Ukr

aine

(UA

) and

Ukr

aine

Wes

t (U

A-W

)

ATBA

BEBG

CHCZ

DEDK

EEES

FIFR

GBGR

HRHU

IEIT

LTLU

LVME

2MK

NINL

NOPL

PTRO

RSSE

SISK

AL3

BY3

MA3

MD3

RU3

TR3

UA3

UA-

W3

AT-

--

-73

5887

5357

--

--

--

--

1630

-10

72-

--

--

--

--

--

--

2381

--

--

--

--

-BA

--

--

--

--

--

--

--

3539

--

--

--

1821

--

--

--

-31

6-

--

--

--

--

--

BE-

--

--

--

--

--

2329

--

--

--

-13

20-

--

-70

10-

--

--

--

--

--

--

--

-BG

--

--

--

--

--

--

-28

23-

--

--

--

-29

18-

--

--

568

2621

--

--

--

--

3070

--

CH10

4-

--

--

2762

--

--

1834

--

--

-25

612

--

--

--

--

--

--

--

--

--

--

--

-CZ

1005

5-

--

--

9408

--

--

--

--

--

--

--

--

--

-45

--

--

-79

91-

--

--

--

-DE

1592

3-

--

1400

018

86-

2906

--

-13

9-

--

--

--

5779

--

--

9589

-51

38-

--

628

--

--

--

--

--

DK-

--

--

-50

55-

--

--

--

--

--

--

--

--

-24

14-

--

-28

07-

--

--

--

--

-EE

--

--

--

--

--

1657

--

--

--

--

-26

33-

--

--

--

--

--

--

--

-69

6-

--

ES-

--

--

--

--

--

2462

--

--

--

--

--

--

--

-66

85-

--

--

--

4509

--

--

-FI

--

--

--

--

480

--

--

--

--

--

--

--

--

127

--

--

4007

--

--

--

0-

--

FR-

-71

18-

1230

1-

203 1

5-

-39

93-

-61

51-

--

-14

307

--

--

--

--

--

--

--

--

--

--

--

-GB

--

--

--

--

--

-13

69-

--

--

--

--

--

1769

706

--

--

--

--

--

--

--

--

GR-

--

0-

--

--

--

--

--

--

1701

--

--

107

--

--

--

--

--

2124

--

--

0-

-HR

-16

22-

--

--

--

--

--

--

10-

--

--

--

--

--

--

96-

4590

--

--

--

--

-HU

697

--

--

--

--

--

--

-61

69-

--

--

--

--

--

--

340

696

--

5-

--

--

--

111

IE-

--

--

--

--

--

--

--

--

--

--

--

243

--

--

--

--

--

--

--

--

-IT

10-

--

431

--

--

--

935

-27

6-

--

--

--

--

--

--

--

--

63-

--

--

--

--

LT-

--

--

--

--

--

--

--

--

--

-44

3-

--

--

--

--

--

--

747

--

155

--

-LU

--

1533

--

-11

24-

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

-LV

--

--

--

--

26-

--

--

--

--

2734

--

--

--

--

--

--

--

--

--

0-

--

ME 2

-40

7-

--

--

--

--

--

--

--

--

--

--

--

--

--

493

--

-n.

a.-

--

--

--

MK-

--

0-

--

--

--

--

1489

--

--

--

--

--

--

--

-59

--

--

--

--

--

-NI

--

--

--

--

--

--

0-

--

733

--

--

--

--

--

--

--

--

--

--

--

--

NL-

-45

21-

--

3221

--

--

-24

94-

--

--

--

--

--

-15

51-

--

--

--

--

--

--

--

NO-

--

--

--

3600

--

131

--

--

--

--

--

--

-33

60-

--

--

6509

--

--

--

0-

--

PL-

--

--

8253

433

--

--

--

--

--

--

--

--

--

--

--

-27

8-

3054

-0

--

--

0-

PT-

--

--

--

--

3928

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

-RO

--

-14

45-

--

--

--

--

--

867

--

--

--

--

--

--

-24

10-

--

--

-0

--

-12

4RS

-21

58-

0-

--

--

--

--

-11

7 626

8-

--

--

1595

1144

--

--

-15

--

--

315

--

--

--

-SE

--

--

--

2047

5141

--

5936

--

--

--

--

--

--

--

6718

1514

--

--

--

--

--

--

--

SI40

2-

--

--

--

--

--

--

3120

--

4786

--

--

--

--

--

--

--

--

--

--

--

-SK

--

--

-22

8-

--

--

--

--

8120

--

--

--

--

--

26-

--

--

--

--

--

--

2127

AL 3

--

--

--

--

--

--

-3

--

--

--

-n.

a.-

--

--

--

209

--

--

--

--

--

-BY

3-

--

--

--

--

--

--

--

--

-29

16-

--

--

--

0-

--

--

--

--

--

--

-MA

3-

--

--

--

--

14-

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

MD 3

--

--

--

--

--

--

--

--

--

--

--

--

--

--

529

--

--

--

--

--

--

RU 3

--

--

--

--

1011

-10

765

--

--

--

-24

36-

934

--

--

212

--

--

--

--

--

--

--

-TR

3-

--

48-

--

--

--

--

2590

--

--

--

--

--

--

--

--

--

--

--

--

--

-UA

3-

--

--

--

--

--

--

--

--

--

--

--

--

-59

--

--

--

--

--

--

--

UA-W

3-

--

--

--

--

--

--

--

3772

--

--

--

--

--

--

1494

--

-17

8-

--

--

--

-

Insi

de fl

ows

of th

e co

untri

esOu

tsid

e flo

ws

coun

tries

Page 17: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 17

Development of the physical exchanges on tie lines

1 External exchanges of the Nordic countries are reliable since 19902 Reliable Baltic data is available since 19953 There were no exchanges between Republic of Ireland and Northern Ireland before 19954 External exchanges include Albania, Belarus, Moldavia, Morocco, Russia, Turkey, Ukraine and Ukraine-West since 20095 Sum of all cross-border exchanges 2011 without exchange data between Montenegro and Albania

Yea

r

Sum

of t

otal

ele

ctric

ity e

xcha

nges

Ext

erna

l exc

hang

es

Yea

r

Sum

of t

otal

ele

ctric

ity e

xcha

nges

Ext

erna

l exc

hang

eshWThWThWThWT

0,52,07149910,08,26579159910,04,566791 2,3 195,4 14,9

8,517,12269910,08,8677917,516,51279910,03,4787912,027,23289910,07,2897914,916,75299910,01,4808914,813,79200020,06,1918916,220,60310020,07,5828913,620,23320020,09,50138911,131,44330020,09,80148916,135,24340020,02,11158915,131,39350020,08,80168910,132,38360020,03,91178915,539,59370020,06,83188916,334,67380020,02,4519891

1990 1 90026,49,071 4 364,7 33,84,436,18301021,58,7511991

11024,42,8612991 5 411,9 41,11993 168,3 4,7

Development of overall cross border exchanges of ENTSO E member TSOs' countries since 1975

0

50

100

150

200

250

300

350

400

45019

7519

7619

7719

7819

7919

8019

8119

8219

8319

8419

8519

8619

8719

8819

8919

9019

9119

9219

9319

9419

9519

9619

9719

9819

9920

0020

0120

0220

0320

0420

0520

0620

0720

0820

0920

1020

11

TWh

ENTSO-E External exchanges

Overview 2011All exchanges: 411,934 TWhENTSO-E : 370,786 TWhExternal: 41,148 TWh

Page 18: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

PT ES

FR

BE LU

IE

NI

GB NL

DK

DE

CH

IT SI

NO

MA

AT

SE

GRIT-G

R

NO-NL

18 ENTSO-E Statistical Yearbook 2011

Synchronous operation with ENTSO-E region

ENTSO-E members

Not ENTSO-E members

SE-DE

Monthly electricity exchangesacross frontiers in Gwh

DK-DENI-IE

NI-G

B

GB-FR

NO-DK

BE-FR LU-B

E

DE-AT

FR-D

E

CH-IT

CH-AT

AT-IT

DE-CH

FR-C

HFR

-IT

IT-S

I

FR-ES

PT-

ES

DK

-SE

ES-MA

AT-SI

LU-D

E

NL-BE

NL-

DE

NO-SE

GB

-NL

3.0002.5002.0001.5001.000

5000

500

1 3 5 7 9 11

600

0

600

1.200

1 3 5 7 9 11

200

1000

100

200

13

57

9111.200

6000

6001.200

1 3 5 7 9 11

2.50

02.

000

1.50

01.

000

5000

500

13

57

911

2000

200

400

600

13

57

911

6000

600

1.20

0

1.80

0

13

57

911

2.0001.5001.000

5000

5001.000

1 3 5 7 9 11

1.800

1.200

600

0

600

1 3 5 7 9 11

800400

0400800

1 3 5 7 9 11

1.000500

0500

1 3 5 7 9 11

800

4000

400

800

13

57

911

1.60

01.

200

800

4000

400

13

57

911

1.40

0

7000

700

13

57

911

5000

5001.000

1 3 5 7 9 11

3000

300

13

57

911

1500

150

1 3 5 7 9 11

150100

500

50

1 3 5 7 9 11

4000

400

1 3 5 7 9 11

5000

5001.000

1 3 5 7 9 11

3000

300

600

13

57

911

600300

0300

1 3 5 7 9 11

500

0

500

1 3 5 7 9 11

6000

600

1 3 5 7 9 1160

0060

0

13

57

911

7000

700

1 3 5 7 9 11

9000

900

13

57

911

2000

200

400

13

57

911

1.5001.000

5000

5001.0001.500

1 3 5 7 9 11

Page 19: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

DE

AT

PL

CZ SK

HU

HR

BA

ME

MK

RS

GR

BG

RO

UA-W

LV

EE

FI

SE

TR

UA

BY

RU

RU

AL

NO

SI

LT

MD

Monthly electricity exchangeson tie lines in GWh

19 ENTSO-E Statistical Yearbook 2011

EE-RU

DE

-PL

GR-AL

BA-ME

ME

-RS MK-BG

GR-MK

GR-BG

HU-HR

RS

-BG

RS

-RO

SI-HR

AT-H

U

DE

-CZ

HR-RS

RS-AL

HU-RS

PL-CZ

SK

-UA

-W

SK-HU HU-UA-W

SE-PL

HR-BA

BA

-RS

BG

-TR

RO-BG

RO

-MD

RO-UA-W

RS-MK

GR

-TR

SE-FI

NO-FI NO-RU

LV-R

U

LT-BY

FI-EE

EE-LV

LV-LT

RU-LT

PL-SK

CZ-

SK

CZ-AT

HU-RO

ME-AL = n.a.

FI-RU

7000

700

1.40

0

13

57

911

1.400700

0700

1 3 5 7 9 11

4000

400

13

57

911

900

600

3000

300

13

57

911

1.200800400

0400

1 3 5 7 9 11

600300

0300

1 3 5 7 9 11

1.20

080

040

0040

0

13

57

911

1.200600

0600

1 3 5 7 9 11

-500

50

1 3 5 7 9 11

PL-UA

4000

400

1 3 5 7 9 11

4000

400800

1 3 5 7 9 11

400

2000

200

13

57

911

400200

0200

1 3 5 7 9 11

1.000

500

0

500

1 3 5 7 9 11

500

50

1 3 5 7 9 11

1.200600

0600

1.200

1 3 5 7 9 11

6000

6001.200

1 3 5 7 9 11

300

30

1 3 5 7 9 11

3000

300

1 3 5 7 9 11300150

0150

1 3 5 7 9 11

4000

400

1 3 5 7 9 11

600300

0300

1 3 5 7 9 11

1500

150

13

57

911

400200

0200

1 3 5 7 9 11 3000

300600

1 3 5 7 9 11

3000

300

13

57

911

1500

150

300

13

57

911

2000

200

1 3 5 7 9 11

1500

150

1 3 5 7 9 11

2500

250

1 3 5 7 9 11

5000

500

1 3 5 7 9 11

3000

300

13

57

911

5000

500

13

57

911

BG

-TR

2500

250

1 3 5 7 9 11

1000

100

13

57

911

2000

200

1 3 5 7 9 11

2500

250

1 3 5 7 9 11

400200

0200

1 3 5 7 9 11

300

0

300

1 3 5 7 9 11300

0

300

1 3 5 7 9 11

400200

0200

1 3 5 7 9 11

3500

350

1 3 5 7 9 11

1000

100

1 3 5 7 9 11

3000

300

13

57

911

3000

300

13

57

911

3000

300

1 3 5 7 9 11

Page 20: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

PT ES

FR

BE LU

IE

NI

GB NL

DK

DE

CH

IT SI

NO

MA

AT

SE

GRIT-G

R

NO-NL

20 ENTSO-E Statistical Yearbook 2011

Synchronous operation with ENTSO-E region

ENTSO-E members

Not ENTSO-E members

SE-DEDK-DENI-IE

NI-G

B

GB-FR

NO-DK

BE-FR LU-B

E

DE-AT

FR-D

E

CH-IT

CH-AT

AT-IT

DE-CH

FR-C

HFR

-IT

IT-S

I

FR-ES

PT-

ES

DK

-SE

ES-MA

AT-SI

LU-D

E

NL-BE

NL-

DE

NO-SE

GB

-NL

Balance of load flows atand in MW03:00 a.m. 11:00 a.m.

350

0

350

1 3 5 7 9 11

5000

500

13

57

911

2.000

1.000

0

1.000

2.000

1 3 5 7 9 11

3.00

0

2.00

0

1.00

00

1.00

0

13

57

911

3.00

0

2.00

0

1.00

00

1.00

0

13

57

911

1.25

00

1.25

0

2.50

0

13

57

911

1.600

800

0

800

1 3 5 7 9 11

1.000500

0500

1 3 5 7 9 11

1.000

0

1.000

2.000

1 3 5 7 9 11

300200100

0100

1 3 5 7 9 11

1.000500

0500

1 3 5 7 9 11

3.000

2.000

1.000

0

1.000

1 3 5 7 9 11

3.000

1.500

0

1.500

1 3 5 7 9 11

2.00

01.

0000

1.00

02.

000

3.00

04.

000

13

57

911

4000

400

800

1.20

0

13

57

911

4.00

0

3.00

0

2.00

0

1.00

00

1.00

0

13

57

911

2.000

0

2.000

1 3 5 7 9 1130

0030

0

13

57

911

2.0001.000

01.0002.000

1 3 5 7 9 11

5.0004.0003.0002.0001.000

01.000

1 3 5 7 9 11

2.000

1.000

0

1.000

2.000

1 3 5 7 9 11

5000

500

1.00

0

13

57

911

700350

0350700

1 3 5 7 9 11

6000

600

13

57

911

800400

0400800

1 3 5 7 9 11

3.000

0

3.000

1 3 5 7 9 11

1.200

0

1.200

1 3 5 7 9 11

2.00

00

2.00

0

13

57

911

1.20

001.

200

13

57

911

Page 21: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

DE

AT

PL

CZ SK

HU

HR

BA

ME

MK

RS

GR

BG

RO

UA-W

LV

EE

FI

SE

TR

UA

BY

RU

RU

AL

NO

SI

LT

MD

21 ENTSO-E Statistical Yearbook 2011

EE-RU

DE

-PL

GR-AL

BA-ME

ME

-RS

MK-BG

GR-MK

GR-BG

HU-HR

RS

-BG

RS

-ROSI-HR

AT-H

U

DE

-CZ

HR-RS

RS-AL

HU-RS

PL-CZ

SK

-UA

-W

SK-HU HU-UA-W

SE-PL

HR-BA

BA

-RS

BG

-TR

RO-BG RO

-MD

RO-UA-W

RS-MK

GR

-TR

SE-FI

NO-FINO-RU

LV-R

U

LT-BY

FI-EE

EE-LV

LV-LT

RU-LT

PL-SK

CZ-

SK

CZ-AT

HU-RO

ME-AL = n.a.

FI-RU

PL-UA

Balance of load flows atand in MW03:00 a.m. 11:00 a.m.

2.000

1.000

0

1.000

1 3 5 7 9 11

8000

800

1.60

0

2.40

0

13

57

911

800

4000

400

13

57

911

1.50

075

0075

01.

500

13

57

911

1.5001.000

5000

500

1 3 5 7 9 11

1.000500

0500

1 3 5 7 9 11

2.00

01.

0000

1.00

0

13

57

911

1.5001.000

5000

500

1 3 5 7 9 11

6000

600

13

57

911

3000

300

1 3 5 7 9 11

1.000500

0500

1 3 5 7 9 11

1.000

0

1.000

1 3 5 7 9 11

700350

0350

1 3 5 7 9 11

1500

150

13

57

911

400

0

400

1 3 5 7 9 11

500

0

500

1 3 5 7 9 11

4000

400

1 3 5 7 9 11

8000

800

13

57

911

3000

300

600

13

57

911

5000

5001.000

1 3 5 7 9 11

400

0

400

1 3 5 7 9 11

3000

300

1 3 5 7 9 11

2000

200400

1 3 5 7 9 11

1.5001.000

5000

500

1 3 5 7 9 11

3000

300

600

13

57

911

3000

300

600

13

57

911

500

0

500

1 3 5 7 9 11

400

0

400

1 3 5 7 9 11500

0

500

1 3 5 7 9 11

600300

0300

1 3 5 7 9 11

150

0

150

1 3 5 7 9 11

500

0

500

1 3 5 7 9 11

4000

400

13

57

911

2500

250

500

13

57

911

500250

0250

1 3 5 7 9 11

80

0

80

1 3 5 7 9 11

800

0

800

1.600

1 3 5 7 9 11

40

0

40

1 3 5 7 9 11

2.000

0

2.000

1 3 5 7 9 11

400

0

400

1 3 5 7 9 11

600300

0300

1 3 5 7 9 11

1.200

6000

600

1 3 5 7 9 11

3000

300

13

57

911

4000

400800

1 3 5 7 9 11

600

0

600

1 3 5 7 9 11

400

0

400

1 3 5 7 9 11

Page 22: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

22 ENTSO-E Statistical Yearbook 2011

1 All values are calculated to represent 100% of the national values.2 Lowest and highest physical hourly vertical load value of the Swiss transmission grid.3 Calculated as sum of the ENTSO-E member TSO's hourly load values.

Highest and lowest hourly load value in each country 2011 in MW 1

Highest hourly load value in each country Lowest hourly load value in each country

Date Day Time MW Date Day Time MW

AT 19 December Monday 06:00 p.m. 9701 16 June Thursday 06:00 a.m. 3794BA 31 December Saturday 06:00 p.m. 2150 22 July Friday 04:00 a.m. 872BE 31 January Monday 07:00 p.m. 14081 22 May Sunday 06:00 a.m. 6336BG 01February Tuesday 08:00 p.m. 6897 25 April Monday 05:00 a.m. 2660CH 2 01 February Tuesday 11:00 a.m. 8083 01 August Monday 08:00 a.m. 2865CY 16 February Wednesday 08:00 p.m. 780 20 April Wednesday 04:00 a.m. 343CZ 01 February Thursday 11:00 a.m. 10210 24 July Sunday 06:00 a.m. 4315DE 07 December Wednesday 06:00 p.m. 83990 13 June Monday 04:00 a.m. 35597DK 05 January Wednesday 06:00 p.m. 6231 24 July Sunday 06:00 a.m. 2177EE 23 February Wednesday 09:00 a.m. 1510 24 June Friday 04:00 a.m. 446ES 24 January Monday 07:00 p.m. 43596 24 April Sunday 07:00 a.m. 17989FI 18 February Friday 09:00 a.m. 14965 26 June Sunday 09:00 a.m. 5219FR 04 January Tuesday 07:00 p.m. 91720 07 August Sunday 07:00 a.m. 31268GB 06 January Thursday 07:00 p.m. 57875 07 August Sunday 07:00 a.m. 20001GR 20 July Wednesday 01:00 p.m. 9868 01 May Sunday 06:00 a.m. 3356HR 25 January Tuesday 07:00 p.m. 2970 25 April Monday 04:00 a.m. 1185HU 24 November Thursday 05:00 p.m. 5931 31 July Sunday 06:00 a.m. 2630IE 13 December Tuesday 07:00 p.m. 4610 08 October Saturday 06:00 a.m. 1586IS 30 November Wednesday 07:00 p.m. 2138 07 October Friday 05:00 a.m. 1346IT 13 July Wednesday 12:00 a.m. 53668 24 April Sunday 07:00 a.m. 20582LT 25 February Friday 09:00 a.m. 1734 26 June Sunday 05:00 a.m. 703LU 21 December Wednesday 06:00 p.m. 1188 28 March Monday 01:00 a.m. 148LV 23 February Wednesday 09:00 a.m. 1239 17 October Monday 05:00 a.m. 141ME 30 October Sunday 03:00 a.m. 746 23 May Monday 06:00 a.m. 305MK 31 December Saturday 03:00 p.m. 1642 26 June Sunday 06:00 a.m. 540NI 10 January Monday 07:00 p.m. 1744 10 July Sunday 07:00 a.m. 538NL 13 December Tuesday 06:00 p.m. 18049 12 June Sunday 07:00 a.m. 8167NO 21 February Monday 09:00 a.m. 22129 24 July Sunday 06:00 a.m. 8665PL 22 December Thursday 06:00 p.m. 22755 25 April Monday 06:00 a.m. 9476PT 24 January Monday 09:00 p.m. 9192 24 April Sunday 06:00 a.m. 3310RO 03 February Thursday 07:00 a.m. 8724 24 April Sunday 03:00 p.m. 4086RS 02 February Wednesday 07:00 p.m. 7341 03 July Sunday 06:00 a.m. 2436SE 23 February Wednesday 07:00 p.m. 26015 23 July Saturday 07:00 a.m. 9261SI 02 March Wednesday 08:00 p.m. 1949 02 May Monday 05:00 a.m. 784SK 02 February Wednesday 06:00 p.m. 4290 31 July Sunday 06:00 a.m. 2213

ENTSO-E 3

01 February Tuesday 07:00 p.m. 532599 31 July Sunday 07:00 a.m. 234658

Page 23: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 23

Highest and lowest load in each country on 3rd Wednesday in 2011

1 All values are calculated to represent 100% of the national values.2 The reported figures are best estimated based on actual measurements.3 Calculated load values as sum of the ENTSO-E member TSOs´ countries.

Highest load on 3 rd Wednesday in each country 1 Lowest load on 3 rd Wednesday in each country1

Country MW Date Time MW Date TimeAT 9442 21 December 06:00 p.m. 4580 17 August 04:00 a.m.BA 1997 21 December 06:00 p.m. 949 15 June 04:00 a.m.BE 2 13881 19 January 07:00 p.m. 7198 20 July 04:00 a.m.BG 6395 16 February 08:00 p.m. 2861 21 September 03:00 a.m.CH 10161 21 December 06:00 p.m. 4991 20 July 04:00 a.m.CY 780 16 February 08:00 p.m. 343 20 April 01:00 a.m.CZ 9672 16 February 04:00 p.m. 5520 17 August 05:00 a.m.DE 80593 16 November 06:00 p.m. 43617 17 August 04:00 a.m.DK 5897 19 January 06:00 p.m. 2423 20 July 05:00 a.m.EE 1495 16 February 09:00 a.m. 520 20 July 04:00 a.m.ES 40073 16 February 08:00 p.m. 21873 16 November 04:00 a.m.FI 14272 16 February 07:00 a.m. 6749 20 July 04:00 a.m.FR 82450 19 January 07:00 p.m. 35416 17 August 05:00 a.m.GB 56621 19 January 07.00 p.m. 24101 15 June 06:00 a.m.GR 9868 20 July 01:00 p.m. 3979 18 May 04:00 a.m.HR 2874 21 December 06:00 p.m. 1443 18 May 03:00 a.m.HU 5705 16 November 06:00 p.m. 3066 16 March 04:00 a.m.IE 4528 19 January 07:00 p.m. 1880 20 July 07:00 a.m.IS 2101 21 December 07:00 p.m. 1730 20 July 03:00 a.m.IT 51050 21 December 06:00 p.m. 25013 17 August 05:00 a.m.LT 1688 21 December 05:00 p.m. 810 15 June 04:00 a.m.LU 1188 21 December 06:00 p.m. 563 17 August 05:00 a.m.LV 1226 16 February 09:00 a.m. 449 15 June 04:00 a.m.ME 648 21 December 07:00 p.m. 323 18 May 05:00 a.m.MK 1486 21 December 03:00 p.m. 624 15 June 04:00 a.m.NI 1681 19 January 07:00 p.m. 556 20 July 07:00 a.m.NL 17346 16 November 06:00 p.m. 9308 20 April 04:00 a.m.NO 21512 16 February 09:00 a.m. 8942 20 July 05:00 a.m.PL 22697 21 December 06:00 p.m. 12696 20 July 05:00 a.m.PT 8575 16 February 09:00 p.m. 4182 17 August 08:00 a.m.RO 8447 16 February 07:00 p.m. 4942 15 June 03:00 a.m.RS 6803 16 February 07:00 p.m. 2612 15 June 05:00 a.m.SE 24238 16 February 07:00 p.m. 10016 20 July 06:00 a.m.SI 1893 16 February 12:00 a.m. 1080 17 August 03:00 a.m.SK 4126 16 February 10:00 a.m. 2492 17 August 03:00 a.m.

ENTSO-E 3 518949 19 January 07:00 p.m. 267285 17 August 04.00 a.m.

ENTSO-E load curve on 19 January 2011

with highest load: 518949 MW 3with lowest load: 350259 MW 3

ENTSO-E load curve on 17 August 2011

with lowest load: 267285 MW 3with highest load: 394813 MW 3

200000

250000

300000

350000

400000

450000

500000

550000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

MW

Page 24: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

24 ENTSO-E Statistical Yearbook 2011

Net generating capacity on 31 December 2010 and 2011 in MWN

GC

Nu

clea

rN

GC

Fo

ssil

fu

els

NG

C H

ydro

po

wer

NG

C R

enew

able

of

wh

ich

win

do

f w

hic

h s

ola

rN

GC

Oth

erN

GC

Su

m

Rep

rese

n-

res

ou

rce

sta

tivi

ty1

MW

MW

MW

MW

MW

MW

MW

MW

%

Co

un

try

2011

2010

2011

2010

2011

2010

2011

2010

2011

2010

2011

2010

2011

2010

2011

2010

2011

2010

AT

00

7425

7389

1291

912

665

1054

1031

1017

1002

00

00

2139

821

085

100

100

BA

00

1506

1506

1971

1971

00

00

00

00

3477

3477

100

100

BE

5926

5945

8539

8668

1420

1421

4142

2659

1056

888

1901

766

00

2002

718

693

100

100

BG

2080

2000

6400

6451

3150

3108

770

513

550

488

220

250

012

400

1207

299

99C

H32

7832

5338

838

413

723

1352

250

835

542

1811

171

205

213

1810

117

727

100

100

CY

00

973

1385

00

102

8210

282

00

00

1075

1467

100

100

CZ

3692

3666

1093

810

892

2161

2203

2190

2177

219

218

1971

1959

00

1898

118

938

100

100

DE

1204

820

300

6696

769

300

9209

1070

053

532

4740

028

254

2660

022

306

1660

032

6345

001

45

01

91

52

20

093

100

DK

00

7486

8867

109

3967

3802

3950

3802

170

4469

711

507

1337

510

010

0EE

00

2283

2324

44

254

156

184

156

00

00

2541

2484

100

100

ES

7525

7525

4365

940

841

1908

119

051

2663

924

641

2072

919

821

4916

4104

00

9690

492

058

100

100

FI26

7626

4689

7890

0431

5731

3322

5422

5419

719

70

044

4417

109

1708

110

010

0F

R63

130

6313

027

789

2740

325

405

2541

810

138

7559

6639

5603

2228

762

00

12

64

62

12

35

10

100

100

GB

1039

710

608

6198

462

535

3876

3887

3355

2630

3355

2630

00

4545

7965

779

705

9089

GR

00

9614

9396

3223

3215

1936

1322

1363

1039

439

153

00

1477

313

933

100

100

HR

00

1787

1781

2110

2113

118

116

118

790

00

040

1540

1010

010

0H

U18

9218

9268

6061

8150

5069

563

032

524

00

00

094

9787

5310

010

0IE

00

6132

6219

508

508

1615

1615

1615

1615

00

242

208

8497

8550

100

100

IS0

052

121

1860

1883

661

575

00

00

00

2573

2579

100

100

IT0

076

287

7497

621

737

2152

120

419

9992

6918

5814

1277

334

700

011

84

43

10

64

89

100

100

LT

00

2544

2539

876

875

252

193

202

161

00

00

3672

3607

100

99L

U0

049

950

911

3411

2891

9541

4340

2716

017

4017

3210

010

0L

V0

085

984

815

5615

5530

5930

370

021

024

6624

6210

010

0M

E0

022

021

066

066

00

00

00

00

088

087

010

010

0M

K0

011

5711

5750

350

30

00

00

00

016

6016

6010

010

0N

IR0

023

3523

174

441

935

840

534

60

07

1427

6526

9310

010

0N

L50

448

020

137

2200

538

3724

3929

4323

4022

7351

6810

120

2413

025

465

100

100

NO

00

1166

1166

3016

430

164

450

450

450

450

00

00

3178

031

780

100

100

PL

00

3011

729

612

2341

2331

2209

1366

2059

1274

10

00

3466

733

309

100

100

PT

00

8779

8547

5392

4988

4855

4370

4081

3705

155

122

00

1902

617

905

100

97R

O13

0013

0089

0191

6661

4460

8710

3050

110

0647

90

00

017

375

1705

410

010

0R

S0

054

7854

7528

8828

840

00

00

00

083

6683

5910

010

0SE

9363

9151

4793

5035

1619

716

200

6094

5315

2899

2163

00

00

3644

735

701

100

100

SI

696

696

1282

1282

1063

1063

00

00

00

00

3041

3041

100

100

SK

1940

1820

2896

2614

2478

2478

753

143

33

507

8285

725

8152

7780

100

100

EN

TSO

E212

6447

1344

1244

7210

4481

0519

7012

1973

3915

2917

1253

0290

149

8122

647

636

2820

949

8464

4692

8624

9116

04

1P

erce

ntag

e as

ref

erre

d to

the

tot

al v

alue

s of

a c

ount

ry

(T

he t

otal

val

ues

of a

cou

ntry

are

def

ined

as

the

sync

hron

ousl

y in

terc

onne

cted

sys

tem

plu

s th

e ar

eas

dire

ctly

con

nect

ed v

ia A

C o

r D

C t

o th

e m

ainl

and

syst

em.)

.2

Cal

cula

ted

sum

of E

NT

SO

-E m

embe

r T

SO

s´co

untr

ies

Page 25: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 25

Inventory of thermal units > 10 MW as of 31 December 2011

1Th

e di

ffere

nce

from

201

0 de

pend

s on

the

expl

osio

n of

the

Vasi

likos

Pow

er S

tatio

n an

d th

e in

trodu

ctio

n of

sm

all T

empo

rary

gen

erat

ing

units

.2

Foss

il fu

els

>= 5

MW

3>

400

MW

: Mot

hbal

led

and

com

mis

sion

ing

units

are

exc

lude

d.4

10 M

W <

x <

200

MW

: Exc

ept f

or th

e ge

nera

tion

of b

io-p

ower

.5

Uni

ts w

ith th

e ca

paci

ty <

10M

W a

re in

clud

ed to

o. N

o pr

ecis

e in

form

atio

n ab

out n

umbe

r of

uni

ts w

ith th

e ca

paci

ty <

50M

W.

6C

alcu

late

d su

m o

f fos

sil f

uels

exc

ept B

G, D

K, N

O, R

S a

nd S

E.

Foss

il fu

els

pow

er u

nits

Cou

ntry

Rep

orte

dye

arN

umbe

rM

WN

umbe

rM

WN

umbe

rM

WN

umbe

rM

WN

umbe

rM

W

AT

2008

6231

468

2735

00

7058

810

0B

A20

116

810

369

60

09

1506

00

BE

2011

6837

0412

3595

312

3283

8531

759

26B

G20

11n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.20

80C

H20

1142

462

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

532

78C

Y 1

2011

3197

3n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.0

0C

Z 2

2010

n.a.

1066

10

01

460

n.a.

1112

16

3692

DE

20

1132

020

600

6720

300

6138

600

448

7950

09

1210

0D

K20

11n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.0

0E

E20

1118

2219

00

00

1822

190

0E

S20

1122

560

6946

1594

937

2048

030

842

498

875

25FI

2010

110

5500

1023

551

565

121

8420

426

71FR

2011

183

6717

2254

6823

1268

622

824

871

5863

130

GB

320

1150

2094

2475

5093

5234

016

761

984

2110

397

GR

2011

2123

6019

5566

416

8844

9614

00

HR

2011

1683

74

950

00

2017

870

0H

U20

1161

3212

1429

841

425

7666

214

1892

IE20

1123

1672

823

244

2136

3561

320

0IS

2011

236

00

00

236

00

IT20

1114

9018

909

106

3163

038

2270

616

3473

245

00

LT4

2011

1414

094

1200

00

1826

090

0LU

2010

00

138

50

01

385

00

LV20

108

540

129

10

09

831

00

ME

2007

119

00

00

01

190

00

MK

2010

230

14

856

00

611

570

0N

IR20

1112

958

496

61

402

1723

260

0N

L20

11n.

a.18

3220

6080

2112

225

n.a.

2013

71

504

NO

2010

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

00

PL

520

11n.

a.13

330

5714

111

526

76n.

a.30

117

00

PT

2010

4919

9116

4888

417

0769

8586

00

RO

2011

8155

2011

3148

00

9286

682

1300

RS

2011

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

SE

2011

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

9363

SI

2007

227

61

312

167

24

1260

169

6S

K20

1141

2420

128

80

042

2708

419

40E

NTS

O-E

629

3811

8748

463

1346

2729

817

1000

3522

4229

4013

012

6494

Tota

l

N

ucle

ar p

ower

uni

ts

200

MW

< x

< 4

00 M

W

10 M

W <

>W

M 002 < x 4

00 M

WTo

tal

Page 26: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

26 ENTSO-E Statistical Yearbook 2011

Inventory of hydro power units > 1MW as of 31 December 2011

1 T

otal

hyd

ro p

ower

uni

ts in

MW

as

repo

rted

NG

C h

ydro

pow

er a

s of

31

Dec

embe

r 201

12

Add

ition

ally

134

MW

in 8

65 H

ydro

pow

er u

nits

with

the

capa

city

<1M

W.

3 C

alcu

late

d su

m e

xcep

t BG,

DK,

NI,

NO

, RS

and

SE4 C

alcu

late

d su

m w

ith re

porte

d va

lues

of N

GC

hyd

ro p

ower

as

of 3

1 D

ecem

ber 2

011

from

BG

, DK

, NI,

NO

, RS

and

SE

Rep

orte

dC

ount

r yye

arN

umbe

rM

WN

umbe

rM

WN

umbe

rM

WN

umbe

rM

WN

umbe

rM

W

AT

2008

582

910

100

2496

1914

7327

6918

728

1179

7B

A20

11n.

a.n.

a.13

343

1276

56

863

3119

71B

E20

1117

597

194

00

611

6430

1417

BG

120

11n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.31

50C

H20

1120

370

310

928

0443

2917

3475

3038

913

954

CY

2011

00

00

00

00

00

CZ

2010

n.a.

280

1023

96

484

611

00n.

a.21

03D

E20

0023

489

878

1648

1410

2615

4841

341

8413

DK

120

11n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.10

EE

2011

00

00

00

00

00

ES

2011

520

1729

138

3135

4329

3738

1105

573

918

856

FI20

1094

351

6523

287

434

00

166

3113

FR20

1155

017

5318

444

6238

2793

6215

955

834

2496

3G

B20

113

2326

587

972

712

2539

5038

76G

R20

1196

174

584

212

011

2845

114

3223

HR

2011

1252

2360

56

453

897

849

2088

HU

2011

1047

00

00

00

1047

IE20

115

2011

196

429

20

020

508

IS20

1111

50.9

1548

411

652

669

043

1877

IT20

1174

323

2923

755

5629

1964

4211

692

1051

2154

1LT

2011

48

410

10

04

900

1210

09LU

2010

320

111

11

110

966

1128

LV20

111

14

7221

1455

00

2615

28M

E20

073

80

00

02

649

565

7M

K20

1012

153

733

265

115

019

503

NI 1

2011

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

4N

L20

113

122

26n.

a.n.

a.n.

a.n.

a.5

38N

O20

11n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.30

164

PL

220

1175

153

2150

45

293

812

5610

922

06P

T20

1011

439

64

903

3321

998

1395

159

4893

RO

2011

193

969

102

2193

1711

759

1670

321

6007

RS

120

11n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.28

88S

E 1

2011

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

1619

7S

I20

071

811

314

531

92

230

1987

1S

K20

1129

190

3673

410

820

673

481

2478

EN

TSO

-E35

18 3

1110

8 3

1209

330

092

333

8 3

2356

4 3

314

376

250

3n.

a.19

3478

4

Inve

ntor

y of

hyd

ro p

ower

uni

ts

> 10

0 M

W

Tota

l50

MW

< x

< 1

00 M

W

1 M

W <

x <

10

MW

10

MW

< x

< 5

0 M

W

Page 27: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

European Network ofTransmission System Operators

for Electricity

1 ENTSO-E Net generation, exchanges

and consumption 2011

2 Yearly values / operation and

physical exchanges

3 System information

4 Glossary of statistical terms

Page 28: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 29: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 29

Yearly values operation and physical exchanges

1 Yearly values operation are available from the year 2009 on. Exchanges with "Other" are inside and outside flows between the ENTSO-E member TSOs' countries and Albania ( AL), Belarus (BY), Morocco (MA),

Republic of Moldavia (MD), Russia (RU), Republic of Turkey (TR), Ukraine (UA) and Ukraine-West (UA-W).Detailed monthly information are available on the ENTSO-E website www.entsoe.eu/Resources/DataPortal.

2 The reported figures are best estimates based on actual measurements and extrapolations.3 Yearly values with the country code GB represents the sum of England, Scotland and Wales.4 Yearly values before the year 2007 are data of the whole country Serbia&Montenegro (CS) and available on the

ENTSO-E website www.entsoe.eu/Resources/DataPortal.5 FYROM = Former Yugoslav Republic of Macedonia6 Yearly values with the country code NI represents the data of the GB Northern Ireland.7 Generation and load values are operational data.

Yearly values operation and physical exchanges per country for the years 2006, 2010 and 2011

Statistical database as of 31 August 2012

Page

Sum of ENTSO-E 1 .................................................................................................................................................................. 31Austria ( AT ) ............................................................................................................................................................................34Bosnia-Herzegovina ( BA ) ...................................................................................................................................................... 36Bulgaria ( BG ) .........................................................................................................................................................................38Belgium 2 ( BE ) .......................................................................................................................................................................40Switzerland ( CH ) ...................................................................................................................................................................42Czech Republic ( CZ ) .............................................................................................................................................................44Germany ( DE ) .......................................................................................................................................................................46Denmark ( DK ) .......................................................................................................................................................................48Estonia (EE ) ...........................................................................................................................................................................50Spain ( ES ) .............................................................................................................................................................................52Finland (FI ) .............................................................................................................................................................................54France ( FR ) ...........................................................................................................................................................................56Great Britain 3 (GB ) ................................................................................................................................................................. 58Greece ( GR ) ..........................................................................................................................................................................60Croatia ( HR ) ..........................................................................................................................................................................62Hungary ( HU ) ........................................................................................................................................................................64Ireland ( IE ) .............................................................................................................................................................................66Cyprus (CY ) ............................................................................................................................................................................68Iceland (IS ) .............................................................................................................................................................................69Italy ( IT ) ..................................................................................................................................................................................70Lithuania (LT ) .........................................................................................................................................................................72Luxembourg ( LU ) ..................................................................................................................................................................74Latvia (LV ) ...............................................................................................................................................................................76Montenegro 4 ( ME ) ................................................................................................................................................................ 78FYROM 5 ( MK ) ........................................................................................................................................................................80GB Northern Ireland 6 ( NI ) ..................................................................................................................................................... 82The Netherlands ( NL ) ...........................................................................................................................................................84Norway (NO ) ...........................................................................................................................................................................86Poland 7 ( PL ) ......................................................................................................................................................................... 88Portugal ( PT ) .........................................................................................................................................................................90Romania ( RO ) .......................................................................................................................................................................92Serbia 4 ( RS ) ......................................................................................................................................................................... 94Sweden (SE ) ..........................................................................................................................................................................96Slovenia ( SI ) ..........................................................................................................................................................................98Slovak Republic ( SK ) ..........................................................................................................................................................100

Page 30: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 31: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 31

1 Including deliveries from industry

Yearly values / OperationSum of ENTSO-E

2006 n.a.Thermal nuclear net generation GWh Σ 2010 896053

2011 885586

2006 n.a.Fossil fuels net generation GWh Σ 2010 1650129

2011 1618830

2006 n.a.Hydraulic net generation GWh Σ 2010 584329

2011 511029

2006 n.a.Other renewable net generation GWh Σ 2010 249443

2011 302983

2006 n.a. - of which wind GWh Σ 2010 138298

2011 165250

2006 n.a. - of which solar GWh Σ 2010 21539

2011 45649

2006 n.a.Non-identifiable net generation GWh Σ 2010 11819

2011 11145

2006 n.a.Total net generation, GWh Σ 2010 1 3403569calculated to represent 100% of the national values 2011 1 3347445

2006 n.a.Sum of physical inside flows GWh Σ 2010 372453

2011 397956

2006 n.a.Sum of physical outside flows GWh Σ 2010 356422

2011 384765

2006 n.a.Total exchange balance GWh Σ 2010 17000

2011 8098

2006 n.a.Consumption of pumps GWh Σ 2010 44954

2011 43225

2006 n.a.National electrical consumption, GWh Σ 2010 3375615calculated to represent 100% of the national values 2011 3311650

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 398614calculated to represent 100% of the national values 16.02.11 360976

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 528684calculated to represent 100% of the national values 19.01.11 496633

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 555852

calculated to represent 100% of the national values 19.01.11 518954

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

19.01.11 19:00

Page 32: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

32 ENTSO-E Statistical Yearbook 2011

OU

TS

IDE

FL

OW

S C

OU

NT

RIE

S

INSIDE FLOWS COUNTRIES

Annual physical electricity exchange in interconnected operation (GWh)ENTSO-E

Year AT BA BE BG CH CZ DE DK EE ES FI FR GB GR HR HU IE

2006 7304 23 5842 465AT 2010 7915 252 6750 1014

2011 7358 87 5357 1630

2006 3647BA 2010 4927

2011 3539

2006 1981BE 2010 5402

2011 2329

2006 4468BG 2010 3453

2011 2823

2006 82 2917 2156CH 2010 53 2581 5120

2011 104 2762 1834

2006 6139 12054CZ 2010 6545 9400

2011 10055 9408

2006 14799 13694 647 3972 838DE 2010 14705 14553 564 6471 795

2011 15923 14000 1886 2906 139

2006 5855DK 2010 2707

2011 5055

2006 7EE 2010 1967

2011 1657

2006 1479ES 2010 3512

2011 2462

2006 7FI 2010 246

2011 480

2006 10644 11322 16172 5910 10929FR 2010 3048 9679 15126 1991 7136

2011 7118 12301 20315 3993 6151

2006 899GB 2010 4109

2011 1369

2006 0GR 2010 1

2011 0

2006 674 1HR 2010 1109 93

2011 1622 10

2006 1062 5561HU 2010 641 3045

2011 697 6169

2006IE 2010

2011

2006 3 422 726 455IT 2010 2 493 1012 72

2011 10 431 935 276

2006LT 2010

2011

2006 2482 804LU 2010 1847 1361

2011 1533 1124

2006 n.a.LV 2010 38

2011 26

2006ME 2010 628

2011 407

2006 0 1202MK 2010 0 3857

2011 0 1489

2006 n.a. n.a.NI 2010 0 744

2011 0 733

2006 5603 283NL 2010 7392 3072

2011 4521 3221 2494

2006 1127 150NO 2010 1458 115

2011 3600 131

2006 10181 722PL 2010 5500 167

2011 8253 433

2006 3183PT 2010 3190

2011 3928

2006 1138 1437RO 2010 1106 1252

2011 1445 867

2006 2341 0 3005 53RS 2010 1319 58 1740 544

2011 2158 0 1176 268

2006 1491 589 3676SE 2010 1007 2656 2636

2011 2047 5141 5936

2006 1062 1036SI 2010 584 2647

2011 402 3120

2006 612 8592SK 2010 366 4934

2011 228 8120

2006 0 n.a. 27 15379 26 48512010 13 1459 33 11636 1141 20602011 48 1011 14 10765 2593 3772

2006 23147 3015 18729 1138 32742 11463 46140 5688 n.a. 9120 15379 8079 n.a. 6151 13249 15399 n.a.2010 22530 3056 12287 1178 32640 6682 42171 10585 1743 5214 16354 19950 7136 8523 12359 9897 7442011 27191 4187 13172 1493 34090 10454 49722 11647 1517 7935 18489 9068 8645 7181 14004 14667 733

Sum of inside flows

Other

Page 33: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 33

ENTSO-EAnnual physical electricity exchange in interconnected operation (GWh)

IT LT LU LV ME MK NI NL NO PL PT RO RS SE SI SK Other

1415 833 158821328 2011 192701072 2381 17885

1476 51231597 362 68861821 316 5676

1697 5019 86971123 5318 118431320 7010 10659

860 710 2837 0 88752953 677 1794 401 92782918 568 2621 3070 12000

23885 2904023176 3093025612 30312

42 5857 24092136 5498 2157945 7991 27499

5134 22336 2548 1944 659126159 8942 5334 2355 598785779 9589 5138 628 55988

2324 1743 99224055 0 117402414 2807 10276

n.a. n.a. n.a.2695 285 49472633 696 4986

8481 1899 118595667 3938 131176685 4509 13656

84 3767 0 3858162 5470 0 5878127 4007 0 4614

14891 6986811583 4856314307 64185

n.a. n.a.2299 64081769 706 3844

945 12 979 19362299 8 493 28011701 107 2124 3932

31 6871 757714 6480 769696 4590 6318

29 1520 0 13 8185146 392 56 426 4706340 696 5 111 8018

n.a. n.a.293 293243 243

12 1618120 169963 1715

n.a. n.a. n.a.234 1951 2185443 902 1345

328632082657

n.a. n.a. n.a.3055 8 31012734 0 2760

1450 305 2383493 n.a. n.a.

0 12020 385759 1548

n.a.744733

58862347 128111551 11787

7667 0 89441329 3691 0 65933360 6509 0 13600

1500 3374 0 15777494 1498 0 7659278 3054 0 12018

318331903928

3262 47 58841968 381 47072410 124 4846

2126 3 261 7789511 2309 74 149 67041595 1144 15 315 6671

7178 264 131987668 761 147286718 1514 21356

5389 74877513 107444786 8308

4 1717 1092583 912 629526 2127 10501

n.a. n.a. 215 1913 893 613 945122 1044 225 209 0 894 1047 2905352 934 n.a. 212 59 2023 209 178

46525 n.a. 6831 n.a. 2998 n.a. 27355 9801 4771 8481 1635 9739 16621 7716 932545899 8177 7282 3973 2333 5270 2592 15589 14441 6314 5667 1791 7027 12010 8611 734247478 8086 7099 4010 n.a. 4169 2012 20665 11022 6782 6685 2946 6900 14229 7034 11228

Sum of outsideflows

Page 34: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1 Other renewable net generation is included in non-identifiable net generation.

Monthly values / Operation

34 ENTSO-E Statistical Yearbook 2011

Austria

2006 0hWGnoitareneg ten raelcun lamrehT 2010 0

2011 0

2006 22481hWGnoitareneg ten sleuf lissoF 2010 24638

2011 23007

2006 34102hWGnoitareneg ten ciluardyH 2010 36496

2011 33663

2006 n.a.Other renewable net generation 1 GWh 2010 n.a.

2011 n.a.

2006 n.a. - of which wind 1 GWh 2010 n.a.

2011 n.a.

2006 n.a. - of which solar 1 GWh 2010 n.a.

2011 n.a.

2006 6407hWGnoitareneg ten elbaifitnedi-noN 2010 9551

2011 8730

2006 62990hWG,noitareneg ten latoT 2010 70685

04561102seulav lanoitan eht fo %001 tneserper ot detaluclac 0

2006 23147hWGswolf edisni lacisyhp fo muS 2010 22530

2011 27191

2006 15882Sum of physical outside flows GWh 2010 19270

2011 17885

2006 6848hWGecnalab egnahcxe latoT 2010 2203

2011 8228

2006 3338hWGspmup fo noitpmusnoC 2010 4564

2011 5061

2006 66500hWG,noitpmusnoc lacirtcele lanoitaN 2010 68324

65861102seulav lanoitan eht fo %001 tneserper ot detaluclac 7

18.01.06 6638Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 7020

14611.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 3

18.01.06 8951Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 9217

02911.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 2

20.12.06 9222Highest load on the 3rd Wednesday, MW max. 15.12.10 9548

44911.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 2

20.12.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

21.12.11 18:00

Page 35: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 35

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

lin

es (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1A

ust

ria

MM_YY

AT CH

AT CZ

AT DE

AT HU

AT IT

AT SI

Sum_ OF

CH AT

CZ AT

DE AT

HU AT

IT AT

SI AT

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

754

041

92

7510

1260

063

117

0619

62

222

2757

1497

II.06

687

440

53

8914

1202

052

715

3113

81

158

2355

1153

III.0

669

67

541

1111

225

1392

142

514

0512

30

128

2082

690

IV.0

661

32

548

4311

313

914

581

421

1050

106

012

1590

132

V.0

637

42

622

2514

086

1249

1148

563

811

20

612

523

VI.0

669

40

687

4911

398

1641

042

889

962

025

1414

-227

VII.

0651

14

823

3713

110

816

1428

392

898

120

7314

03-2

11V

III.0

648

93

652

2613

796

1403

2012

384

318

10

5612

23-1

80IX

.06

486

035

851

114

6510

7412

649

1108

580

8519

1283

8X

.06

615

027

747

133

9011

621

672

1449

390

112

2273

1111

XI.0

661

01

322

125

124

5212

345

575

1360

60

4619

9275

8X

II.06

775

018

846

134

5011

933

811

1912

290

139

2894

1701

2006

7304

2358

4246

514

1583

315

882

8261

3914

799

1062

310

6223

147

7265

I.10

861

1251

031

106

127

1647

073

516

6315

035

2448

801

II.10

747

441

935

102

146

1453

071

815

137

036

2274

821

III.1

081

45

415

3611

910

414

930

620

1675

50

3323

3384

0IV

.10

703

424

942

112

8011

901

690

1577

690

5523

9212

02V

.10

614

5459

683

125

111

1583

136

710

0060

030

1458

-125

VI.1

048

640

804

115

119

204

1768

432

370

116

010

1054

-714

VII.

1046

15

544

201

127

337

1675

1762

485

39

00

1503

-172

VIII

.10

450

2770

216

893

170

1610

1438

273

314

26

1151

-459

IX.1

062

323

617

140

104

233

1740

644

996

927

01

1452

-288

X.1

061

51

539

113

9136

417

236

767

1178

650

320

1929

6X

I.10

724

1056

237

118

130

1581

155

513

7614

90

7221

5357

2X

II.10

817

6779

313

112

518

073

315

1467

205

030

322

9348

620

1079

1525

267

5010

1413

2820

1119

270

5365

4514

705

641

258

422

530

3260

I.11

885

1578

828

9728

1841

155

815

8915

80

169

2475

634

II.11

827

044

253

7811

115

111

720

1653

540

2724

5594

4III

.11

771

344

741

102

111

1475

274

116

4475

082

2544

1069

IV.1

159

612

386

4882

127

1251

579

712

8559

033

2179

928

V.1

135

712

549

6893

274

1353

388

682

011

31

618

2947

6V

I.11

617

2064

767

109

220

1680

158

895

910

30

1316

64-1

6V

II.11

430

938

222

110

834

414

9420

850

1037

140

319

2443

0V

III.1

143

65

514

228

118

513

6923

795

1006

110

1118

4647

7IX

.11

275

735

832

168

163

1192

4185

310

127

818

1939

747

X.1

174

54

509

178

112

242

1790

291

913

6641

018

2346

556

XI.1

172

00

113

191

118

327

1469

110

6616

8523

07

2782

1313

XII.

1169

90

222

186

104

249

1460

412

8218

6739

115

3208

1748

2011

7358

8753

5716

3010

7223

8117

885

104

1005

515

923

697

1040

227

191

9306

Page 36: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

36 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationBosnia-Herzegovina

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 7452Fossil fuels net generation GWh Σ 2010 7684

2011 9404

2006 5857Hydraulic net generation GWh Σ 2010 7870

2011 4290

2006 0Other renewable net generation 1 GWh Σ 2010 0

2011 0

2006 0 - of which wind 1 GWh Σ 2010 0

2011 0

2006 n.a. - of which solar 1 GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 13309Total net generation, GWh Σ 2010 15554calculated to represent 100% of the national values 2011 13694

2006 3015Sum of physical inside flows GWh Σ 2010 3056

2011 3780

2006 5123Sum of physical outside flows GWh Σ 2010 6886

2011 3855

2006 -2200Total exchange balance GWh Σ 2010 -3827

2011 -1487

2006 0Consumption of pumps GWh Σ 2010 2

2011 21

2006 11109National electrical consumption, GWh Σ 2010 11725calculated to represent 100% of the national values 2011 12186

15.02.06 1162Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1220calculated to represent 100% of the national values 21.12.11 1205

20.12.06 1644Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1812calculated to represent 100% of the national values 21.12.11 1797

20.12.06 1826Highest load on the 3rd Wednesday, MW max. 15.12.10 2051

calculated to represent 100% of the national values 21.12.11 1997

20.12.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

21.12.11 18:00

Page 37: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e cr

oss-

fron

tier t

rans

mis

sion

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l phy

sica

l bal

ance

in th

e ta

ble

"Mon

thly

val

ues

/ Ope

ratio

n".

ENTSO-E Statistical Yearbook 2011 37

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1B

osn

ia-H

erze

go

vin

a

MM_YY

BA CS

BA HR

BA ME

BA RS

Sum_ OF

HR CS

HR BA

ME BA

RS BA

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

159

352

511

106

6216

8-3

43II

.06

101

298

399

127

7620

3-1

96III

.06

739

139

880

6414

4-2

54IV

.06

100

395

495

8764

151

-344

V.0

610

535

245

720

851

259

-198

VI.0

660

320

380

264

6532

9-5

1V

II.06

9436

145

523

025

255

-200

VIII

.06

170

259

429

220

4126

1-1

68IX

.06

163

206

369

200

4624

6-1

23X

.06

191

242

433

252

5831

0-1

23X

I.06

184

234

418

252

5330

5-1

13X

II.06

142

237

379

315

6938

45

2006

1476

3647

5123

2341

674

3015

-210

8

I.10

426

258

7175

597

4629

172

-583

II.10

465

181

3067

653

4454

151

-525

III.1

052

017

838

736

6150

3214

3-5

93IV

.10

448

6120

529

6757

6418

8-3

41V

.10

528

7454

656

6955

2214

6-5

10V

I.10

373

777

457

5789

114

260

-197

VII.

1020

715

57

369

115

3324

739

526

VIII

.10

111

210

832

920

610

209

425

96IX

.10

229

139

1238

012

126

211

358

-22

X.1

040

062

1447

699

4219

733

8-1

38X

I.10

522

7032

624

8678

9525

9-3

65X

II.10

698

132

6989

978

9845

221

-678

2010

4927

1597

362

6886

1109

628

1319

3056

-383

0

I.11

504

156

2868

876

6110

023

7-4

51II.

1130

114

919

469

100

4314

228

5-1

84III

.11

472

133

761

274

4217

729

3-3

19IV

.11

375

667

448

7967

243

389

-59

V.1

141

743

846

864

7420

734

5-1

23V

I.11

335

5411

400

4546

193

284

-116

VII.

1127

212

215

409

9029

167

286

-123

VIII

.11

175

206

3141

217

19

174

354

-58

IX.1

120

716

821

396

151

1025

341

418

X.1

124

613

429

409

112

1813

926

9-1

40X

I.11

143

277

4946

928

53

182

470

1X

II.11

9231

391

496

375

518

156

165

2011

3539

1821

316

5676

1622

407

2158

4187

-148

9

Page 38: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

38 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationBelgium

2006 44315Thermal nuclear net generation GWh Σ 2010 45729

2011 45943

2006 32567Fossil fuels net generation GWh Σ 2010 36770

2011 28996

2006 1613Hydraulic net generation GWh Σ 2010 1646

2011 1410

2006 3400Other renewable net generation GWh Σ 2010 7286

2011 9279

2006 359 - of which wind GWh Σ 2010 1286

2011 2307

2006 n.a. - of which solar GWh Σ 2010 556

2011 1493

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 81895Total net generation, GWh Σ 2010 1 91431calculated to represent 100% of the national values 2011 1 85628

2006 18729Sum of physical inside flows GWh Σ 2010 12395

2011 13189

2006 8697Sum of physical outside flows GWh Σ 2010 11844

2011 10652

2006 10157Total exchange balance GWh Σ 2010 551

2011 2537

2006 1690Consumption of pumps GWh Σ 2010 1786

2011 1629

2006 90362National electrical consumption, GWh Σ 2010 90196calculated to represent 100% of the national values 2011 86536

15.02.06 10350Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 11066calculated to represent 100% of the national values 19.01.11 10174

15.02.06 12770Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 13390calculated to represent 100% of the national values 19.01.11 13246

20.12.06 13385Highest load on the 3rd Wednesday, MW max. 15.12.10 14039

calculated to represent 100% of the national values 19.01.11 13881

20.12.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

19.01.11 19:00

Page 39: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 39

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1B

elg

ium

MM_YY

BE FR

BE LU

BE NL

Sum_ OF

FR BE

LU BE

NL BE

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

320

147

6453

129

622

288

814

0687

5II.

0656

412

729

720

127

130

1118

1375

655

III.0

644

614

727

620

265

227

1275

1767

1147

IV.0

611

139

412

562

1032

201

419

1652

1090

V.0

615

162

443

620

1114

223

323

1660

1040

VI.0

623

161

771

955

1230

239

190

1659

704

VII.

0652

179

801

1032

1272

226

137

1635

603

VIII

.06

3085

860

975

1456

192

616

5467

9IX

.06

1513

279

093

714

6820

275

1745

808

X.0

646

146

521

713

1062

186

120

1368

655

XI.0

689

143

222

454

952

208

303

1463

1009

XII.

0637

012

979

578

370

226

749

1345

767

2006

1981

1697

5019

8697

1064

424

8256

0318

729

1003

2

I.10

805

9611

110

1211

116

094

712

1820

6II.

1060

188

258

947

8415

367

090

7-4

0III

.10

610

104

326

1040

140

157

623

920

-120

IV.1

044

910

826

482

115

314

245

675

1-7

0V

.10

596

133

428

1157

155

102

586

843

-314

VI.1

011

773

745

935

566

160

326

1052

117

VII.

1017

810

084

111

1938

015

424

678

0-3

39V

III.1

012

652

1168

1346

478

152

183

813

-533

IX.1

024

810

357

192

235

914

539

289

6-2

6X

.10

849

108

200

1157

8017

310

6713

2016

3X

I.10

499

9928

288

022

215

482

812

0432

4X

II.10

324

5912

450

732

019

510

6815

8310

7620

1054

0211

2353

1811

843

3048

1847

7392

1228

744

4

I.11

145

112

292

549

633

169

559

1361

812

II.11

9910

121

241

256

515

742

511

4773

5III

.11

120

100

401

621

769

166

484

1419

798

IV.1

115

699

586

841

628

155

235

1018

177

V.1

113

912

487

811

4172

415

411

899

6-1

45V

I.11

6512

310

1111

9910

3517

185

1291

92V

II.11

102

138

1109

1349

812

144

144

1100

-249

VIII

.11

111

111

1110

1332

656

1418

185

1-4

81IX

.11

8115

780

410

4263

10

243

874

-168

X.1

138

910

724

073

620

936

673

918

182

XI.1

146

179

187

727

220

186

639

1045

318

XII.

1146

169

180

710

236

181

735

1152

442

2011

2329

1320

7010

1065

971

1815

3345

2113

172

2513

Page 40: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

40 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationBulgaria

2006 18957Thermal nuclear net generation GWh Σ 2010 14181

2011 15172

2006 20480Fossil fuels net generation GWh Σ 2010 21084

2011 25889

2006 4497Hydraulic net generation GWh Σ 2010 5431

2011 3542

2006 0Other renewable net generation GWh Σ 2010 331

2011 540

2006 0 - of which wind GWh Σ 2010 331

2011 540

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 43934Total net generation, GWh Σ 2010 41027calculated to represent 100% of the national values 2011 45143

2006 1138Sum of physical inside flows GWh Σ 2010 1178

2011 1493

2006 8875Sum of physical outside flows GWh Σ 2010 9278

2011 12000

2006 -7806Total exchange balance GWh Σ 2010 -8517

2011 -10726

2006 456Consumption of pumps GWh Σ 2010 973

2011 1184

2006 35672National electrical consumption, GWh Σ 2010 31537

calculated to represent 100% of the national values 2011 33233

15.02.06 5004Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 4399calculated to represent 100% of the national values 16.02.11 4407

15.02.06 6041Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 20.01.10 6076calculated to represent 100% of the national values 16.02.11 5903

20.12.06 6340Highest load on the 3rd Wednesday, MW max. 15.12.10 6640

calculated to represent 100% of the national values 16.02.11 6395

20.12.06 20:00Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

16.02.11 20:00

Page 41: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 41

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1B

ulg

aria

MM_YY

BG CS

BG GR

BG MK

BG RO

BG RS

BG TR

Sum_ OF

CS BG

GR BG

MK BG

RO BG

RS BG

TR BG

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

338

427

7832

087

50

00

740

74-8

01II.

0633

242

273

400

867

00

055

055

-812

III.0

630

242

368

700

863

00

065

065

-798

IV.0

623

137

065

660

732

00

013

013

-719

V.0

622

520

246

550

528

00

041

041

-487

VI.0

618

340

392

820

760

00

070

070

-690

VII.

0615

839

269

840

703

00

085

085

-618

VIII

.06

280

406

7810

20

866

00

014

10

141

-725

IX.0

610

034

472

151

066

70

00

740

74-5

93X

.06

152

318

7126

056

70

00

850

85-4

82X

I.06

223

350

722

064

70

00

248

024

8-3

99X

II.06

313

411

760

080

00

00

187

018

7-6

1320

0628

3744

6886

071

00

8875

00

011

380

1138

-773

7

I.10

214

183

1287

049

60

017

55

018

0-3

16II.

1022

720

227

124

058

01

085

00

86-4

94III

.10

279

198

2271

057

00

080

30

83-4

87IV

.10

243

171

2537

047

60

073

170

90-3

86V

.10

167

139

118

240

448

00

6233

095

-353

VI.1

034

525

816

714

80

918

00

20

02

-916

VII.

1045

838

793

226

011

640

023

00

23-1

141

VIII

.10

480

412

2123

30

1146

00

115

00

115

-103

1IX

.10

353

314

3117

40

872

00

134

00

134

-738

X.1

022

021

672

193

070

10

023

90

023

9-4

62X

I.10

245

245

3622

620

996

10

076

012

88-8

73X

II.10

222

228

5325

119

294

60

042

01

43-9

0320

1034

5329

5367

717

9440

192

781

011

0658

1311

78-8

100

I.11

230

233

1618

919

185

90

013

30

113

4-7

25II.

1125

025

314

222

223

962

00

158

00

158

-804

III.1

124

024

410

192

197

883

00

191

00

191

-692

IV.1

122

724

523

261

204

960

00

830

083

-877

V.1

116

321

915

524

421

910

000

078

02

80-9

20V

I.11

224

224

108

219

151

926

00

100

111

-915

VII.

1130

228

170

191

419

1263

00

500

050

-121

3V

III.1

130

523

016

184

352

1087

00

138

044

182

-905

IX.1

123

325

444

225

314

1070

00

990

099

-971

X.1

118

619

075

175

290

916

00

171

00

171

-745

XI.1

122

526

722

243

255

1012

00

181

00

181

-831

XII.

1123

827

815

276

255

1062

00

153

00

153

-909

2011

2823

2918

568

2621

3070

1200

00

014

450

4814

93-1

0507

Page 42: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

42 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationSwitzerland

2 Calculations based on the ENTSO-E database differ from the official values of the Swiss Federal Office of Energy.

2006 26244Thermal nuclear net generation GWh Σ 2010 25205

2011 25560

2006 2282Fossil fuels net generation GWh Σ 2010 2208

2011 2107

2006 32558Hydraulic net generation GWh Σ 2010 37450

2011 33795

2006 1059Other renewable net generation GWh Σ 2010 1389

2011 1419

2006 6 - of which wind GWh Σ 2010 24

2011 60

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 62143Total net generation, GWh Σ 2010 1 66252calculated to represent 100% of the national values 2011 1 62881

2006 32742Sum of physical inside flows GWh Σ 2010 32640

2011 34090

2006 29040Sum of physical outside flows GWh Σ 2010 30930

2011 30312

2006 3800Total exchange balance GWh Σ 2010 1951

2011 4024

2006 2720Consumption of pumps GWh Σ 2010 2494

2011 2466

2006 2 63223National electrical consumption, GWh Σ 2010 2 65709calculated to represent 100% of the national values 2011 2 64439

15.03.06 7717Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 8381calculated to represent 100% of the national values 21.12.11 7432

18.01.06 10049Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 10532calculated to represent 100% of the national values 21.01.11 9910

15.02.06 10218Highest load on the 3rd Wednesday, MW max. 15.12.10 10835

calculated to represent 100% of the national values 21.01.11 10161

15.02.06 10:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

21.01.11 18:00

Page 43: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 43

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1S

wit

zerl

and

MM_YY

CH AT

CH DE

CH FR

CH IT

Sum_ OF

AT CH

DE CH

FR CH

IT CH

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

012

043

910

5816

1775

416

3978

414

933

2617

09II.

060

110

509

1089

1708

687

1523

627

129

2966

1258

III.0

61

9236

514

1218

7069

614

2687

098

3090

1220

IV.0

61

202

521

6423

7261

396

111

510

2725

353

V.0

611

438

3620

6225

4737

453

996

02

1875

-672

VI.0

60

234

6221

7924

7569

496

264

25

2303

-172

VII.

0628

520

271

2118

2937

511

698

525

2917

63-1

174

VIII

.06

2029

228

1756

2096

489

698

1031

222

2012

4IX

.06

1240

610

022

3027

4848

680

796

81

2262

-486

X.0

61

208

7227

3830

1961

512

0711

925

3019

0X

I.06

520

255

2472

2734

610

1377

1355

133

4360

9X

II.06

393

214

2607

2917

775

1857

1217

138

5093

320

0682

2917

2156

2388

529

040

7304

1369

411

322

422

3274

237

02

I.10

090

652

1686

2428

861

1656

745

5233

1488

6II.

100

5742

619

0323

8674

716

6084

027

3274

888

III.1

00

9032

421

8525

9981

417

1310

8445

3656

1057

IV.1

01

143

147

2126

2417

703

1260

924

4429

3151

4V

.10

127

027

620

0325

5061

463

967

260

1985

-565

VI.1

04

548

165

1953

2670

486

486

748

6517

85-8

85V

II.10

1742

836

225

0333

1046

178

164

127

1910

-140

0V

III.1

014

406

246

1730

2396

450

795

786

920

40-3

56IX

.10

621

637

717

8423

8362

311

4678

317

2569

186

X.1

06

124

697

2043

2870

615

1520

858

1630

0913

9X

I.10

110

654

318

1724

6772

414

3390

227

3086

619

XII.

103

103

905

1443

2454

817

1464

696

104

3081

627

2010

5325

8151

2023

176

3093

079

1514

553

9679

493

3264

017

10

I.11

171

461

2058

2591

885

1640

1037

4036

0210

11II.

111

5524

223

2826

2682

717

5410

6818

3667

1041

III.1

12

128

153

2108

2391

771

1627

1173

9236

6312

72IV

.11

528

815

2053

2361

596

948

1113

4627

0334

2V

.11

342

226

1800

2251

357

744

980

3321

14-1

37V

I.11

134

574

1897

2317

617

647

867

8222

13-1

04V

II.11

2050

478

2343

2945

430

672

947

2120

70-8

75V

III.1

123

230

115

1527

1895

436

793

842

3621

0721

2IX

.11

4135

121

616

9022

9827

559

288

325

1775

-523

X.1

12

137

129

2686

2954

745

1230

983

1329

7117

XI.1

11

132

167

2563

2863

720

1579

1164

1434

7761

4X

II.11

499

158

2559

2820

699

1774

1244

1137

2890

820

1110

427

6218

3425

612

3031

273

5814

000

1230

143

134

090

3778

Page 44: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

44 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationCzech Republic

2006 24499Thermal nuclear net generation GWh Σ 2010 26441

2011 26709

2006 49972Fossil fuels net generation GWh Σ 2010 48713

2011 48998

2006 3244Hydraulic net generation GWh Σ 2010 3380

2011 2821

2006 175Other renewable net generation GWh Σ 2010 948

2011 2500

2006 49 - of which wind GWh Σ 2010 334

2011 384

2006 n.a. - of which solar GWh Σ 2010 604

2011 2115

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 77890Total net generation, GWh Σ 2010 1 79482calculated to represent 100% of the national values 2011 1 81028

2006 11463Sum of physical inside flows GWh Σ 2010 6682

2011 10454

2006 24092Sum of physical outside flows GWh Σ 2010 21579

2011 27499

2006 -12632Total exchange balance GWh Σ 2010 -14949

2011 -17044

2006 950Consumption of pumps GWh Σ 2010 797

2011 944

2006 64308National electrical consumption, GWh Σ 2010 63736calculated to represent 100% of the national values 2011 63040

18.01.06 8353Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 7989calculated to represent 100% of the national values 16.02.11 7524

18.01.06 9722Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 9944calculated to represent 100% of the national values 16.02.11 9560

18.01.06 10095Highest load on the 3rd Wednesday, MW max. 15.12.10 10307

calculated to represent 100% of the national values 16.02.11 9672

18.01.06 17:00Time of highest load on the 3rd Wednesday CET 15.12.10 17:00

16.02.11 16:00

Page 45: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 45

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1C

zech

Rep

ub

lic

MM_YY

CZ AT

CZ DE

CZ PL

CZ SK

Sum_ OF

AT CZ

DE CZ

PL CZ

SK CZ

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ows

(OF)

Insi

de f

low

s (I

F)B

alan

ce

I.06

631

1027

049

521

530

111

1174

107

1392

-761

II.06

527

1015

044

519

874

9310

4369

1209

-778

III.0

642

513

001

371

2097

72

1025

9711

31-9

66IV

.06

421

1083

128

717

922

183

163

897

-895

V.0

648

511

018

316

1910

20

781

8086

3-1

047

VI.0

642

810

048

317

1757

00

584

4963

3-1

124

VII.

0639

210

9010

408

1900

41

558

3960

2-1

298

VIII

.06

123

1035

1259

717

673

553

834

580

-118

7IX

.06

649

754

145

718

610

1169

56

712

-114

9X

.06

672

769

062

720

680

9786

629

992

-107

6X

I.06

575

927

174

322

461

121

1043

1411

79-1

067

XII.

0681

194

90

794

2554

020

510

4325

1273

-128

120

0661

3912

054

4258

5724

092

2364

710

181

612

1146

3-1

2629

I.10

735

971

440

921

1912

4152

124

598

-152

1II.

1071

883

12

475

2026

435

643

668

8-1

338

III.1

062

011

004

421

2145

517

511

1654

9-1

596

IV.1

069

078

33

457

1933

417

451

1949

1-1

442

V.1

036

748

418

346

1215

5447

360

2848

9-7

26V

I.10

323

632

2530

612

8640

4226

034

376

-910

VII.

1062

468

88

861

2181

553

442

150

1-1

680

VIII

.10

382

560

1443

113

8727

7832

222

449

-938

IX.1

044

968

228

591

1750

2345

416

649

0-1

260

X.1

076

772

611

677

2181

192

618

771

8-1

463

XI.1

055

584

55

388

1793

1078

550

5469

2-1

101

XII.

1031

510

9814

136

1563

6719

406

149

641

-922

2010

6545

9400

136

5498

2157

925

256

455

0036

666

82-1

4897

I.11

558

1309

1019

720

7415

644

073

534

-154

0II.

1172

081

96

442

1987

011

658

219

717

-127

0III

.11

741

1033

546

622

453

6369

849

813

-143

2IV

.11

797

839

643

420

7612

7358

032

697

-137

9V

.11

886

800

645

121

4312

3851

426

590

-155

3V

I.11

588

754

643

017

7820

1847

321

532

-124

6V

II.11

850

415

187

921

459

226

866

611

07-1

038

VIII

.11

795

429

398

422

115

9582

10

921

-129

0IX

.11

853

512

268

920

567

221

577

180

6-1

250

X.1

191

988

70

928

2734

416

477

21

941

-179

3X

I.11

1066

709

099

027

650

291

921

012

12-1

553

XII.

1112

8290

20

1101

3285

057

510

090

1584

-170

120

1110

055

9408

4579

9127

499

8718

8682

5322

810

454

-170

45

Page 46: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

46 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationGermany

2006 158725Thermal nuclear net generation GWh Σ 2010 133373

2011 101458

2006 359126Fossil fuels net generation GWh Σ 2010 344278

2011 350456

2006 23997Hydraulic net generation GWh Σ 2010 21698

2011 19853

2006 45964Other renewable net generation GWh Σ 2010 73801

2011 86123

2006 32295 - of which wind GWh Σ 2010 36665

2011 44641

2006 n.a. - of which solar GWh Σ 2010 10874

2011 18341

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 587812Total net generation, GWh Σ 2010 1 573150calculated to represent 100% of the national values 2011 1 557890

2006 46140Sum of physical inside flows GWh Σ 2010 42171

2011 49722

2006 65912Sum of physical outside flows GWh Σ 2010 59878

2011 55988

2006 -19771Total exchange balance GWh Σ 2010 -17707

2011 -6276

2006 8963Consumption of pumps GWh Σ 2010 8021

2011 7347

2006 559078National electrical consumption, GWh Σ 2010 547422calculated to represent 100% of the national values 2011 544267

18.01.06 59000Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 65661calculated to represent 100% of the national values 16.11.11 54573

18.01.06 78574Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 80694calculated to represent 100% of the national values 19.01.11 78280

15.02.06 80750Highest load on the 3rd Wednesday, MW max. 15.12.10 83090

calculated to represent 100% of the national values 16.11.11 80593

15.02.06 19:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

16.11.11 18:00

Page 47: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 47

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1G

erm

any

M M _Y Y

D E A T

DE CH

D E C Z

DE DK

DE D K_W

DE DK _E

D E FR

D E LU

D E N L

DE P L

DE S E

S um _ O F

A T D E

CH D E

C Z D E

DK D E

DK _W D E

DK _E D E

FR D E

LU D E

N L D E

P L D E

S E D E

S um _IF

S um _IF - S um _O F

I.06

1706

1639

111

2222

123

466

2486

303

2369

0141

912

010

2777

029

153

469

09

233

3472

-342

9II.

0615

3115

2393

718

350

416

2322

279

2565

6440

511

010

1572

329

727

561

07

272

3165

-339

9III

.06

1405

1426

243

114

266

442

2759

231

147

6835

541

9213

0058

517

943

664

013

131

3341

-349

4IV

.06

1050

961

120

021

410

406

2113

5625

852

6954

820

210

8324

468

1520

670

9474

3900

-136

9V.

0663

853

90

258

725

426

2031

120

147

4236

622

438

1101

226

2416

6676

144

112

4310

74VI

.06

899

962

026

522

520

416

1564

1124

146

0368

723

410

0422

886

1567

728

212

7641

74-4

29VI

I.06

898

698

119

417

644

440

1178

153

136

3918

823

520

1090

247

166

1258

6735

102

187

4495

577

VIII.

0684

369

85

437

360

039

292

978

339

4081

652

292

1035

4613

2118

6021

413

311

4574

493

IX.0

611

0880

711

236

233

442

211

1588

216

4240

358

406

754

122

2919

8065

2277

2038

33-4

07X.

0614

4912

0797

237

236

044

714

7828

718

656

2427

720

876

924

410

320

5172

230

5138

07-1

817

XI.0

613

6013

7712

169

161

043

419

8641

115

660

7532

220

292

737

617

116

9064

01

146

3899

-217

6XI

I.06

1912

1857

205

109

6416

427

2375

531

7075

6618

893

949

412

205

1077

671

017

831

70-4

396

2006

1479

913

694

647

2077

1895

838

5134

2233

625

4819

4465

912

5842

2917

1205

442

2316

3216

172

804

283

722

1491

4614

0-1

9772

I.10

1663

1656

4161

423

954

264

354

832

962

7551

090

971

205

576

116

239

31

2711

-356

4II.

1015

1316

6035

663

5748

641

058

437

457

8241

957

831

115

910

104

247

00

2683

-309

9III

.10

1675

1713

1783

628

511

362

622

293

6057

415

9011

0047

1308

103

555

01

3619

-243

8IV

.10

1577

1260

1746

57

518

881

584

8553

9424

914

378

323

212

4412

911

40

3229

26-2

468

V.10

1000

639

4729

652

562

1036

360

3140

2359

627

048

441

192

015

520

910

230

3285

-738

VI.1

070

148

642

471

350

792

016

161

3352

804

548

632

240

1934

111

191

4222

047

2213

70VI

I.10

853

781

5343

96

482

943

525

139

4221

544

428

688

424

1690

8213

85

199

4198

-23

VIII.

1073

379

578

583

043

557

640

512

737

3270

240

656

016

824

0877

291

2510

247

3910

07IX

.10

969

1146

4559

46

470

584

254

254

4322

617

216

682

178

1507

8932

716

4136

73-6

49X.

1011

7815

2092

423

168

521

330

513

224

4969

539

124

726

368

924

109

481

197

3369

-160

0XI

.10

1376

1433

7837

799

546

707

466

206

5288

562

106

845

257

1096

138

210

1679

3309

-197

9XI

I.10

1467

1464

1971

013

057

915

5031

223

264

6379

310

310

9862

609

148

7049

529

37-3

526

2010

1470

514

553

564

6471

795

6159

8942

5334

2355

5987

867

5025

8194

0027

0715

126

1361

3072

167

1007

4217

1-1

7707

I.11

1589

1640

672

827

567

1578

207

191

6533

788

7113

0997

1236

140

1171

1837

41-2

792

II.11

1653

1754

116

511

1854

010

2239

915

261

6544

255

819

123

1275

139

6114

1429

42-3

223

III.1

116

4416

2763

538

1556

698

929

112

658

5944

712

810

3314

016

4819

786

7229

3780

-207

9IV

.11

1285

948

7335

016

515

730

319

4342

7938

628

883

945

718

1912

322

827

2241

89-9

0V.

1182

074

438

248

044

027

916

013

2742

549

422

800

241

2232

4954

212

123

4979

2237

VI.1

195

964

718

171

234

279

521

942

3195

647

345

754

519

2201

025

077

256

5049

1854

VII.1

110

3767

222

672

141

368

863

011

3750

382

504

415

540

2274

4730

94

303

4778

1028

VIII.

1110

0679

395

8010

452

555

413

1034

1451

423

042

947

419

3779

424

1629

343

9698

2IX

.11

1012

592

221

458

471

588

319

032

5635

835

151

254

013

9279

396

2222

738

7762

1X.

1113

6612

3016

447

3551

276

463

611

4765

509

137

887

524

1149

101

321

616

537

99-9

66XI

.11

1685

1579

291

263

482

594

712

853

8011

313

270

967

416

5480

427

333

041

22-1

258

XII.1

118

6717

7457

590

447

910

0783

321

6650

222

9990

272

614

9890

166

036

740

70-2

580

2011

1592

314

000

1886

2906

139

5779

9589

5138

628

5598

853

5727

6294

0850

5520

315

1124

3221

433

2047

4972

2-6

266

Bala

nce

Insi

de fl

ows

(IF)

Out

side

flow

s (O

F)

Page 48: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

48 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / Operation Denmark

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 37198Fossil fuels net generation GWh Σ 2010 26294

2011 21811

2006 23Hydraulic net generation GWh Σ 2010 23

2011 19

2006 6107Other renewable net generation GWh Σ 2010 10445

2011 11309

2006 6107 - of which wind GWh Σ 2010 7813

2011 8938

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 43328Total net generation, GWh Σ 2010 1 36762calculated to represent 100% of the national values 2011 1 33139

2006 n.a.Sum of physical inside flows GWh Σ 2010 10585

2011 11647

2006 n.a.Sum of physical outside flows GWh Σ 2010 11740

2011 10276

2006 -6936Total exchange balance GWh Σ 2010 -1122

2011 1319

2006 0Consumption of pumps GWh Σ 2010 0

2011 0

2006 36392National electrical consumption, GWh Σ 2010 35640calculated to represent 100% of the national values 2011 34458

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 3653calculated to represent 100% of the national values 16.02.11 3502

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 5945calculated to represent 100% of the national values 16.02.11 5610

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 6312

calculated to represent 100% of the national values 19.01.11 5897

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

19.01.11 18:00

Page 49: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 49

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1 D

enm

ark

MM_YY

DK_W DE

DK_E DE

DK DE

DK_W NO

DK NO

DK_W SE

DK SE

Sum_ OF

DE DK_W

DE DK_E

DE DK

NO DK_W

NO DK

SE DK_W

SE DK

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

770

291

8471

1216

2222

269

7238

5-8

31II.

0672

329

750

6711

377

1814

581

251

-886

III.0

658

517

917

915

811

0143

114

7817

252

-849

IV.0

624

468

261

105

678

200

214

3037

481

-197

V.0

622

624

203

107

560

258

7253

8346

6-9

4V

I.06

228

8618

016

465

826

522

587

2059

7-6

1V

II.06

247

166

138

8763

819

417

614

390

603

-35

VIII

.06

4613

254

301

614

437

360

297

833

219

IX.0

612

229

240

212

603

236

233

329

510

-93

X.0

624

410

323

617

375

623

723

657

6859

8-1

58X

I.06

376

171

196

193

936

6916

178

3033

8-5

98X

II.06

412

205

303

105

1025

109

6412

675

374

-651

2006

4223

1632

2324

1743

9922

2077

1895

1127

589

5688

-423

4

I.10

205

384

680

1269

614

130

374

7-5

22II.

1011

547

979

013

8466

349

271

4-6

70III

.10

4762

979

614

7283

62

784

5-6

27IV

.10

232

420

290

942

465

3412

662

5-3

17V

.10

411

337

4479

229

612

453

595

516

3V

I.10

240

243

3852

147

111

769

712

8576

4V

II.10

424

163

8667

343

927

764

713

6369

0V

III.1

016

815

513

245

558

320

435

711

4468

9IX

.10

178

159

467

804

594

214

6287

066

X.1

036

824

146

110

7042

318

498

705

-365

XI.1

025

735

235

996

837

789

117

583

-385

XII.

1062

493

835

1390

710

345

749

-641

2010

2707

4055

4978

1174

064

7114

5826

5610

585

-115

5

I.11

9759

973

914

3572

86

3176

5-6

70II.

1112

353

577

514

3351

18

1953

8-8

95III

.11

140

586

555

1281

538

1049

597

-684

IV.1

145

730

425

710

1835

015

638

889

4-1

24V

.11

241

190

115

546

248

203

337

788

242

VI.1

151

919

3357

117

117

377

411

1854

7V

II.11

540

046

586

7253

182

114

2483

8V

III.1

147

46

2750

780

632

693

1405

898

IX.1

154

00

854

845

561

783

1389

841

X.1

152

49

4657

947

517

375

939

360

XI.1

167

412

8677

226

506

393

925

153

XII.

1172

615

412

010

0090

297

478

865

-135

2011

5055

2414

2807

1027

629

0636

0051

4111

647

1371

Page 50: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

50 ENTSO-E Statistical Yearbook 2011

Yearly values / Operation Estonia

2006 n.a.Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 n.a.Fossil fuels net generation GWh Σ 2010 10465

2011 10271

2006 n.a.Hydraulic net generation GWh Σ 2010 27

2011 33

2006 n.a.Other renewable net generation GWh Σ 2010 836

2011 1085

2006 n.a. - of which wind GWh Σ 2010 276

2011 364

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 n.a.Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 n.a.Total net generation, GWh Σ 2010 11328calculated to represent 100% of the national values 2011 11389

2006 n.a.Sum of physical inside flows GWh Σ 2010 1743

2011 1517

2006 n.a.Sum of physical outside flows GWh Σ 2010 4947

2011 4986

2006 n.a.Total exchange balance GWh Σ 2010 -3317

2011 -3562

2006 n.a.Consumption of pumps GWh Σ 2010 0

2011 0

2006 n.a.National electrical consumption, GWh Σ 2010 8011calculated to represent 100% of the national values 2011 7827

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 20.01.10 1038calculated to represent 100% of the national values 16.02.11 1098

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 20.01.10 1445calculated to represent 100% of the national values 16.02.11 1450

n.a.Highest load on the 3rd Wednesday, MW max. 20.01.10 1495

calculated to represent 100% of the national values 16.02.11 1495

n.a.Time of highest load on the 3rd Wednesday CET 20.01.10 17:00

16.02.11 9:00

Page 51: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 51

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1 E

sto

nia

MM_YY

EE FI

EE LV

EE RU

Sum_ OF

FI EE

LV EE

RU EE

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

II.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IV

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IX

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.X

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.20

067

n.a

.n

.a.

n.a

.4

n.a

.n

.a.

n.a

.n

.a.

I.10

213

116

833

70

814

915

7-1

80II.

1022

312

67

356

01

134

135

-221

III.1

024

612

612

384

013

9210

5-2

79IV

.10

222

907

319

115

196

212

-107

V.1

017

215

136

359

241

7710

2-2

57V

I.10

121

232

6041

324

063

87-3

26V

II.10

9033

734

461

310

102

133

-328

VIII

.10

4528

445

374

610

4610

7-2

67IX

.10

6631

427

407

650

8515

0-2

57X

.10

101

323

3145

530

011

414

4-3

11X

I.10

200

251

1046

110

014

415

4-3

07X

II.10

268

345

862

10

025

725

7-3

6420

1019

6726

9528

549

4724

638

1459

1743

-320

4

I.11

254

207

1047

10

011

311

3-3

58II.

1117

117

67

354

00

145

145

-209

III.1

126

414

219

425

02

9810

0-3

25IV

.11

245

7417

336

122

183

206

-130

V.1

119

417

922

395

10

144

145

-250

VI.1

113

829

045

473

80

9199

-374

VII.

1140

347

6745

490

051

141

-313

VIII

.11

7324

488

405

260

2652

-353

IX.1

120

265

125

410

118

229

149

-261

X.1

115

317

9342

516

90

4821

7-2

08X

I.11

104

239

109

452

340

4882

-370

XII.

1113

915

394

386

330

3568

-318

2011

1657

2633

696

4986

480

2610

1115

17-3

469

Page 52: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

52 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationSpain

2006 57417Thermal nuclear net generation GWh Σ 2010 59310

2011 55050

2006 148906Fossil fuels net generation GWh Σ 2010 114052

2011 121327

2006 28884Hydraulic net generation GWh Σ 2010 44617

2011 32173

2006 26782Other renewable net generation GWh Σ 2010 55057

2011 55594

2006 22737 - of which wind GWh Σ 2010 43357

2011 41661

2006 n.a. - of which solar GWh Σ 2010 6718

2011 9597

2006 0Non-identifiable net generation GWh Σ 2010 364

2011 341

2006 268007Total net generation, GWh Σ 2010 273400calculated to represent 100% of the national values 2011 264485

2006 9120Sum of physical inside flows GWh Σ 2010 5214

2011 7935

2006 11859Sum of physical outside flows GWh Σ 2010 13117

2011 13656

2006 -3280Total exchange balance GWh Σ 2010 -8333

2011 -6127

2006 5262Consumption of pumps GWh Σ 2010 4458

2011 3368

2006 259465National electrical consumption, GWh Σ 2010 260609calculated to represent 100% of the national values 2011 254990

20.12.06 27472Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 21.07.10 25404calculated to represent 100% of the national values 19.01.11 25119

20.12.06 40658Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 40073calculated to represent 100% of the national values 16.02.11 39181

20.12.06 42744Highest load on the 3rd Wednesday, MW max. 15.12.10 41455

calculated to represent 100% of the national values 16.02.11 40073

20.12.06 19:00Time of highest load on the 3rd Wednesday CET 15.12.10 20:00

16.02.11 20:00

Page 53: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 53

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1S

pain

MM_YY

ES FR

ES PT

ES MA

Sum_ OF

FR ES

PT ES

MA ES

Sum_IF

Sum_IF - Sum_OF

I.06

121

914

8411

1958

222

36

811

-308

II.06

166

806

156

1128

338

251

259

1-5

37III

.06

265

824

158

1247

165

330

349

8-7

49IV

.06

8654

111

674

352

727

14

802

59V

.06

1372

70

740

700

196

089

615

6V

I.06

6381

210

598

057

915

11

731

-249

VII.

0616

377

510

310

4142

725

43

684

-357

VIII

.06

4364

320

989

568

729

90

986

91IX

.06

3780

821

510

6067

711

00

787

-273

X.0

678

783

206

1067

595

258

585

8-2

09X

I.06

208

502

220

930

327

357

168

5-2

45X

II.06

236

346

327

909

306

483

279

1-1

1820

0614

7984

8118

9911

859

5910

3183

2791

20-2

739

I.10

468

336

195

999

122

617

274

1-2

58II.

1037

141

678

865

4735

09

406

-459

III.1

044

038

516

198

691

358

1246

1-5

25IV

.10

363

323

346

1032

3628

70

323

-709

V.1

023

934

533

892

210

729

10

398

-524

VI.1

022

953

440

211

6524

612

20

368

-797

VII.

1018

667

143

812

9522

010

00

320

-975

VIII

.10

7569

148

612

5245

880

053

8-7

14IX

.10

200

603

491

1294

279

870

366

-928

X.1

030

068

949

814

8714

870

021

8-1

269

XI.1

020

145

630

195

818

323

21

416

-542

XII.

1044

021

820

486

254

596

965

9-2

0320

1035

1256

6739

3813

117

1991

3190

3352

14-7

903

I.11

337

499

296

1132

113

465

358

1-5

51II.

1121

828

928

479

134

461

149

6-2

95III

.11

443

498

321

1262

5948

82

549

-713

IV.1

131

669

741

114

2416

319

70

360

-106

4V

.11

165

386

409

960

308

436

074

4-2

16V

I.11

132

542

406

1080

481

224

070

5-3

75V

II.11

9367

449

912

6657

024

00

810

-456

VIII

.11

5058

052

111

5165

330

10

954

-197

IX.1

110

467

743

412

1545

623

10

687

-528

X.1

113

659

735

910

9248

525

50

740

-352

XI.1

125

052

626

810

4415

033

86

494

-550

XII.

1121

872

030

112

3952

129

22

815

-424

2011

2462

6685

4509

1365

639

9339

2814

7935

-572

1

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 54: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

54 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationFinland

2006 22000Thermal nuclear net generation GWh Σ 2010 21884

2011 22266

2006 33890Fossil fuels net generation GWh Σ 2010 30961

2011 24167

2006 11300Hydraulic net generation GWh Σ 2010 12765

2011 12279

2006 11400Other renewable net generation GWh Σ 2010 10646

2011 10989

2006 200 - of which wind GWh Σ 2010 293

2011 482

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 711

2011 692

2006 1 78590Total net generation, GWh Σ 2010 1 76967calculated to represent 100% of the national values 2011 1 70393

2006 11521Sum of physical inside flows GWh Σ 2010 16354

2011 18489

2006 n.a.Sum of physical outside flows GWh Σ 2010 5878

2011 4614

2006 11521Total exchange balance GWh Σ 2010 10500

2011 13851

2006 0Consumption of pumps GWh Σ 2010 0

2011 0

2006 90111National electrical consumption, GWh Σ 2010 87467calculated to represent 100% of the national values 2011 84244

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 11501calculated to represent 100% of the national values 16.02.11 12617

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 13591calculated to represent 100% of the national values 16.02.11 13992

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 13923

calculated to represent 100% of the national values 16.02.11 14272

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 16:00

16.02.11 7:00

Page 55: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 55

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1F

inla

nd

MM_YY

FI EE

FI NO

FI SE

FI RU

Sum_ OF

EE FI

NO FI

SE FI

RU FI

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

II.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IV

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IX

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.X

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.20

067

8437

670

3858

415

036

7611

549

1537

911

521

I.10

014

329

034

321

33

100

1065

1381

1038

II.10

021

557

057

822

30

157

932

1312

734

III.1

00

4094

60

986

246

01

1060

1307

321

IV.1

01

3688

10

918

222

011

934

1167

249

V.1

024

1339

60

433

172

919

110

1913

9195

8V

I.10

245

296

032

512

14

189

976

1290

965

VII.

1031

536

072

9038

698

494

1320

1248

VIII

.10

610

430

104

4524

570

990

1629

1525

IX.1

065

027

70

342

6621

235

1023

1345

1003

X.1

030

150

20

533

101

1117

410

5913

4581

2X

I.10

1017

472

049

920

02

234

1031

1467

968

XII.

100

1073

50

745

268

376

1053

1400

655

2010

246

162

5470

058

7819

6711

526

3611

636

1635

410

476

I.11

015

722

073

725

41

8910

5013

9465

7II.

110

2237

30

395

171

122

293

613

3093

5III

.11

035

865

090

026

40

510

4013

0940

9IV

.11

119

617

063

724

51

2210

1812

8664

9V

.11

13

427

043

119

412

6310

6413

3390

2V

I.11

80

231

023

913

833

263

1034

1468

1229

VII.

1190

013

010

340

3310

8057

117

2416

21V

III.1

126

511

042

736

1044

784

1907

1865

IX.1

111

85

230

146

206

972

983

1981

1835

X.1

116

90

910

260

1519

849

646

1529

1269

XI.1

134

033

40

368

104

1967

181

516

0912

41X

II.11

3323

300

035

613

90

656

824

1619

1263

2011

480

127

4007

046

1416

5713

159

3610

765

1848

913

875

Page 56: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

56 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationFrance

2006 428674Thermal nuclear net generation GWh Σ 2010 407877

2011 421118

2006 53952Fossil fuels net generation GWh Σ 2010 59453

2011 51505

2006 60927Hydraulic net generation GWh Σ 2010 67995

2011 50267

2006 5521Other renewable net generation GWh Σ 2010 14984

2011 20059

2006 2222 - of which wind GWh Σ 2010 9603

2011 12075

2006 n.a. - of which solar GWh Σ 2010 562

2011 2415

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 549074Total net generation, GWh Σ 2010 550309calculated to represent 100% of the national values 2011 542950

2006 8079Sum of physical inside flows GWh Σ 2010 19950

2011 9068

2006 69868Sum of physical outside flows GWh Σ 2010 48563

2011 64185

2006 -63272Total exchange balance GWh Σ 2010 -30520

2011 -56873

2006 7442Consumption of pumps GWh Σ 2010 6497

2011 6834

2006 478360National electrical consumption, GWh Σ 2010 513292calculated to represent 100% of the national values 2011 479242

20.12.06 65988Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 78377calculated to represent 100% of the national values 16.02.11 62648

20.12.06 76392Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 93188calculated to represent 100% of the national values 19.01.11 78514

20.12.06 80966Highest load on the 3rd Wednesday, MW max. 15.12.10 96710

calculated to represent 100% of the national values 19.01.11 82450

20.12.06 19:00Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

19.01.11 19:00

Page 57: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 57

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1F

ran

ce

MM_YY

FR BE

FR CH

FR DE

FR ES

FR GB

FR IT

Sum_ OF

BE FR

CH FR

DE FR

ES FR

GB FR

IT FR

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)

I.06

296

784

534

582

968

694

3858

320

439

123

121

8112

212

06-2

652

II.06

127

627

275

338

610

694

2671

564

509

350

166

191

103

1883

-788

III.0

626

587

043

616

511

2610

4239

0444

636

526

626

548

100

1490

-241

4IV

.06

1032

1151

1520

527

1395

1614

7239

115

1086

036

148

-709

1V

.06

1114

960

1666

700

1318

1439

7197

1536

513

042

111

-708

6V

I.06

1230

642

1567

579

680

1366

6064

2362

2063

5244

264

-580

0V

II.06

1272

525

1258

427

741

1249

5472

5227

144

163

7254

656

-481

6V

III.0

614

5610

3121

1868

796

286

071

1430

280

4320

3215

3-6

961

IX.0

614

6896

819

8067

763

913

9571

2715

100

437

6932

257

-687

0X

.06

1062

1192

2051

595

941

1619

7460

4672

078

3136

263

-719

7X

I.06

952

1355

1690

327

939

1546

6809

8955

020

865

4746

4-6

345

XII.

0637

012

1710

7730

661

013

7349

5337

021

416

236

270

7811

84-3

769

2006

1064

411

322

1617

259

1010

929

1489

169

868

1981

2156

838

1479

899

726

8079

-617

89

I.10

111

745

576

122

145

811

2510

805

652

239

468

797

115

3076

566

II.10

8484

091

047

222

1057

3160

601

426

5737

171

475

2244

-916

III.1

014

010

8413

0891

336

1171

4130

610

324

2844

070

177

2180

-195

0IV

.10

153

924

1244

3638

110

2037

5844

914

77

363

314

8313

63-2

395

V.1

015

567

292

010

767

186

133

8659

627

652

239

186

5514

04-1

982

VI.1

056

674

819

3424

699

212

3057

1611

716

53

229

1435

563

-515

3V

II.10

380

641

1690

220

1033

1311

5275

178

362

618

621

6681

9-4

456

VIII

.10

478

786

2408

458

1297

839

6266

126

246

075

496

547

-571

9IX

.10

359

783

1507

279

594

947

4469

248

377

620

012

248

1001

-346

8X

.10

8085

892

414

824

786

731

2484

969

716

830

059

911

127

24-4

00X

I.10

222

902

1096

183

548

957

3908

499

543

9920

135

587

1784

-212

4X

II.10

320

696

609

5467

051

228

6132

490

513

044

028

216

422

45-6

1620

1030

4896

7915

126

1991

7136

1158

348

563

5402

5120

795

3512

4109

1012

1995

0-2

8613

I.11

633

1037

1236

113

736

1119

4874

145

461

2733

722

113

813

29-3

545

II.11

565

1068

1275

3451

212

0646

6099

242

1821

824

394

914

-374

6III

.11

769

1173

1648

5949

512

6154

0512

015

315

443

112

8893

1-4

474

IV.1

162

811

1318

1916

348

313

3955

4515

615

1631

627

6759

7-4

948

V.1

172

498

022

3230

834

311

3157

1813

926

016

515

351

534

-518

4V

I.11

1035

867

2201

481

568

1094

6246

6574

213

27

5533

5-5

911

VII.

1181

294

722

7457

066

610

7363

4210

278

193

056

330

-601

2V

III.1

165

684

219

3765

360

685

555

4911

111

510

507

8637

9-5

170

IX.1

163

188

313

9245

635

592

546

4281

216

810

435

8152

5-4

117

X.1

120

998

311

4948

524

914

8545

6038

912

935

136

139

5488

2-3

678

XI.1

122

011

6416

5415

031

315

0650

0746

116

73

250

364

6113

06-3

701

XII.

1123

612

4414

9852

182

513

1356

3746

115

84

218

6110

410

06-4

631

2011

7118

1230

120

315

3993

6151

1430

764

185

2329

1834

139

2462

1369

935

9068

-551

17

Bal

ance

Page 58: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

58 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationGreat Britain

2006 n.a.Thermal nuclear net generation GWh Σ 2010 58203

2011 64550

2006 n.a.Fossil fuels net generation GWh Σ 2010 254647

2011 230036

2006 n.a.Hydraulic net generation GWh Σ 2010 5207

2011 6661

2006 n.a.Other renewable net generation GWh Σ 2010 3327

2011 9170

2006 n.a. - of which wind GWh Σ 2010 3327

2011 9170

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 n.a.Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 n.a.Total net generation, GWh Σ 2010 332569calculated to represent 100% of the national values 2011 328289

2006 n.a.Sum of physical inside flows GWh Σ 2010 7136

2011 8645

2006 n.a.Sum of physical outside flows GWh Σ 2010 6408

2011 3844

2006 n.a.Total exchange balance GWh Σ 2010 6185

2011 4676

2006 n.a.Consumption of pumps GWh Σ 2010 3045

2011 3850

2006 n.a.National electrical consumption, GWh Σ 2010 335709calculated to represent 100% of the national values 2011 329115

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 37697calculated to represent 100% of the national values 21.12.11 36061

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 52261calculated to represent 100% of the national values 19.01.11 50237

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 59008

calculated to represent 100% of the national values 19.01.11 56621

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

19.01.11 19:00

Page 59: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 59

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1G

reat

Bri

tain

MM_YY

GB FR

GB NI

GB NL

Sum_ OF

FR GB

NI GB

NL GB

Sum_IF

Sum_IF - Sum_OF

I.06

81n.

a.n.

a.96

8n.

a.n.

a.n.

a.II.

0619

1n.

a.n.

a.61

0n.

a.n.

a.n.

a.III

.06

48n.

a.n.

a.11

26n.

a.n.

a.n.

a.IV

.06

0n.

a.n.

a.13

95n.

a.n.

a.n.

a.V

.06

0n.

a.n.

a.13

18n.

a.n.

a.n.

a.V

I.06

52n.

a.n.

a.68

0n.

a.n.

a.n.

a.V

II.06

72n.

a.n.

a.74

1n.

a.n.

a.n.

a.V

III.0

620

n.a.

n.a.

962

n.a.

n.a.

n.a.

IX.0

669

n.a.

n.a.

639

n.a.

n.a.

n.a.

X.0

631

n.a.

n.a.

941

n.a.

n.a.

n.a.

XI.0

665

n.a.

n.a.

939

n.a.

n.a.

n.a.

XII.

0627

0n.

a.n.

a.61

0n.

a.n.

a.n.

a.20

0689

9n

.a.

n.a

.10

929

n.a

.n

.a.

n.a

.

I.10

797

235

1032

145

014

5-8

87II.

1071

421

893

222

20

222

-710

III.1

070

124

894

933

60

336

-613

IV.1

031

419

050

438

10

381

-123

V.1

018

622

340

967

10

671

262

VI.1

014

8296

992

099

289

6V

II.10

2115

517

610

330

1033

857

VIII

.10

422

022

412

970

1297

1073

IX.1

012

213

425

659

40

594

338

X.1

059

913

973

824

70

247

-491

XI.1

035

516

552

054

80

548

28X

II.10

282

290

572

670

067

098

2010

4109

2299

6408

7136

071

3672

8

I.11

221

300

052

173

60

073

621

5II.

1124

323

50

478

512

00

512

34III

.11

112

262

037

449

50

049

512

1IV

.11

2723

228

287

483

029

978

249

5V

.11

153

242

7547

034

30

8142

4-4

6V

I.11

723

567

309

568

031

087

856

9V

II.11

015

426

180

666

040

210

6888

8V

III.1

17

109

5116

760

60

397

1003

836

IX.1

135

010

714

235

50

237

592

450

X.1

113

90

9623

524

90

197

446

211

XI.1

136

40

219

583

313

012

143

4-1

49X

II.11

610

3798

825

045

012

7511

7720

1113

6917

6970

638

4461

510

2494

8645

4801

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 60: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

60 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationGreece

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 42653Fossil fuels net generation GWh Σ 2010 37920

2011 42431

2006 6449Hydraulic net generation GWh Σ 2010 7457

2011 4254

2006 1293Other renewable net generation GWh Σ 2010 2503

2011 3379

2006 1199 - of which wind GWh Σ 2010 2062

2011 2594

2006 n.a. - of which solar GWh Σ 2010 133

2011 441

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 50395Total net generation, GWh Σ 2010 1 47880calculated to represent 100% of the national values 2011 1 50064

2006 6151Sum of physical inside flows GWh Σ 2010 8523

2011 7181

2006 1936Sum of physical outside flows GWh Σ 2010 2801

2011 3932

2006 4203Total exchange balance GWh Σ 2010 5708

2011 3231

2006 610Consumption of pumps GWh Σ 2010 37

2011 380

2006 53988National electrical consumption, GWh Σ 2010 53551calculated to represent 100% of the national values 2011 52915

19.07.06 5280Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 21.07.10 6230calculated to represent 100% of the national values 20.07.11 6723

21.06.06 8370Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 21.07.10 9279calculated to represent 100% of the national values 20.07.11 9322

21.06.06 8586Highest load on the 3rd Wednesday, MW max. 16.06.10 9732

calculated to represent 100% of the national values 20.07.11 9868

21.06.06 13:00Time of highest load on the 3rd Wednesday CET 16.06.10 13:00

20.07.11 13:00

Page 61: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 61

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1G

reec

e

MM_YY

GR BG

GR IT

GR MK

GR AL

GR TR

Sum_ OF

BG GR

IT GR

MK GR

AL GR

TR GR

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

016

91

125

295

427

456

048

719

2II.

060

501

125

176

422

058

048

030

4III

.06

022

20

9231

442

30

117

054

022

6IV

.06

017

30

2119

437

03

127

450

431

0V

.06

014

90

315

220

20

119

2134

219

0V

I.06

019

143

6340

34

109

151

745

4V

II.06

07

075

8239

214

181

058

750

5V

III.0

60

40

7377

406

7511

00

591

514

IX.0

60

341

6196

344

4880

047

237

6X

.06

050

810

916

731

869

790

466

299

XI.0

60

400

9213

235

010

010

10

551

419

XII.

060

280

160

188

411

138

650

614

426

2006

094

512

979

1936

4468

455

1202

2661

5142

15

I.10

031

20

190

331

214

228

622

052

419

3II.

101

200

013

021

422

71

312

140

554

340

III.1

00

206

01

020

727

915

357

770

728

521

IV.1

00

710

10

7224

317

356

910

707

635

V.1

00

00

20

216

70

359

105

063

162

9V

I.10

041

017

058

345

1150

726

088

983

1V

II.10

023

90

105

034

445

83

502

00

963

619

VIII

.10

021

30

114

032

748

011

481

00

972

645

IX.1

00

163

011

20

275

353

130

80

109

771

496

X.1

00

282

659

034

722

05

120

1423

058

924

2X

I.10

024

11

260

268

245

612

823

212

614

346

XII.

100

331

124

035

622

20

141

3318

558

122

520

101

2299

849

30

2801

3453

7238

5740

573

685

2357

22

I.11

028

70

630

350

230

515

33

190

581

231

II.11

016

80

150

031

825

03

173

022

264

833

0III

.11

027

80

154

043

224

00

212

019

564

721

5IV

.11

096

319

20

291

227

013

40

201

562

271

V.1

10

103

1927

00

392

163

285

021

946

977

VI.1

10

483

200

025

122

448

123

023

763

238

1V

II.11

011

60

154

027

030

213

208

023

075

348

3V

III.1

10

157

017

30

330

305

423

20

186

727

397

IX.1

10

104

1614

50

265

233

341

018

446

119

6X

.11

011

09

164

028

318

64

620

224

476

193

XI.1

10

135

3522

60

396

225

8523

026

860

120

5X

II.11

099

2223

30

354

238

109

430

234

624

270

2011

017

0110

721

240

3932

2823

276

1489

325

9071

8132

49

Page 62: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

62 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationCroatia

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 5264Fossil fuels net generation GWh Σ 2010 4801

2011 5161

2006 6082Hydraulic net generation GWh Σ 2010 8313

2011 4583

2006 24Other renewable net generation GWh Σ 2010 135

2011 217

2006 17 - of which wind GWh Σ 2010 117

2011 182

2006 n.a. - of which solar GWh Σ 2010 1

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 2

2011 0

2006 1 11370Total net generation, GWh Σ 2010 1 13251calculated to represent 100% of the national values 2011 1 9961

2006 13249Sum of physical inside flows GWh Σ 2010 12359

2011 14004

2006 7577Sum of physical outside flows GWh Σ 2010 7696

2011 6318

2006 5619Total exchange balance GWh Σ 2010 4479

2011 7710

2006 179Consumption of pumps GWh Σ 2010 136

2011 173

2006 16810National electrical consumption, GWh Σ 2010 17594calculated to represent 100% of the national values 2011 17498

15.02.06 1664Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1919calculated to represent 100% of the national values 19.01.11 1698

18.01.06 2669Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 2814calculated to represent 100% of the national values 21.12.11 2570

20.12.06 2817Highest load on the 3rd Wednesday, MW max. 15.12.10 3116

calculated to represent 100% of the national values 21.12.11 2874

20.12.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

21.12.11 18:00

Page 63: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 63

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1C

roat

ia

MM_YY

HR BA

HR CS

HR HU

HR RS

HR SI

Sum_ OF

BA HR

CS HR

HU HR

RS HR

SI HR

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

620

076

282

435

235

055

114

1267

443

II.06

760

070

778

329

836

554

910

1222

439

III.0

664

71

724

796

391

384

510

1913

0450

8IV

.06

649

079

987

239

531

945

417

1185

313

V.0

651

80

602

661

352

206

330

103

991

330

VI.0

665

70

484

556

320

220

371

181

1092

536

VII.

0625

00

493

518

361

182

365

139

1047

529

VIII

.06

410

036

740

825

919

832

720

999

358

5IX

.06

460

037

341

920

616

733

413

283

942

0X

.06

580

051

257

024

221

448

694

1036

466

XI.0

653

00

503

556

234

192

583

7910

8853

2X

II.06

690

054

561

423

720

870

139

1185

571

2006

674

311

6871

7577

3647

3005

5561

1036

1324

956

72

I.10

970

061

471

142

629

914

519

010

6034

9II.

1053

00

708

761

465

313

146

145

1069

308

III.1

061

011

751

823

520

203

149

200

1072

249

IV.1

067

12

656

726

448

138

174

179

939

213

V.1

069

150

585

669

528

4615

326

098

731

8V

I.10

5717

044

551

937

390

170

306

939

420

VII.

1011

50

033

344

820

733

115

935

710

5460

6V

III.1

020

63

010

431

311

134

276

415

944

631

IX.1

012

11

134

046

322

933

986

322

976

513

X.1

099

00

492

591

400

522

133

4811

0351

2X

I.10

864

069

378

352

230

816

013

611

2634

3X

II.10

7852

075

988

969

811

418

989

1090

201

2010

1109

9314

6480

7696

4927

3045

1740

2647

1235

946

63

I.11

766

061

169

350

428

814

213

710

7137

8II.

1110

00

146

456

530

149

085

178

1054

489

III.1

174

20

568

644

472

406

170

129

1177

533

IV.1

179

20

444

525

375

320

180

242

1117

592

V.1

164

00

366

430

417

344

189

329

1279

849

VI.1

145

00

352

397

335

286

152

294

1067

670

VII.

1190

01

313

404

272

467

8132

911

4974

5V

III.1

117

10

522

039

617

560

638

329

1148

752

IX.1

115

10

031

947

020

756

866

270

1111

641

X.1

111

20

438

249

824

656

564

286

1161

663

XI.1

128

50

2525

956

914

384

58

327

1323

754

XII.

1137

50

6029

272

792

984

127

013

4762

020

1116

2210

9645

9063

1835

3961

6911

7631

2014

004

7686

Page 64: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

64 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationHungary

2006 12653Thermal nuclear net generation GWh Σ 2010 14830

2011 14743

2006 18745Fossil fuels net generation GWh Σ 2010 16503

2011 16755

2006 181Hydraulic net generation GWh Σ 2010 181

2011 215

2006 1169Other renewable net generation GWh Σ 2010 2267

2011 1786

2006 41 - of which wind GWh Σ 2010 503

2011 601

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 673Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 33421Total net generation, GWh Σ 2010 33781calculated to represent 100% of the national values 2011 33499

2006 15399Sum of physical inside flows GWh Σ 2010 9897

2011 14667

2006 8185Sum of physical outside flows GWh Σ 2010 4706

2011 8018

2006 7208Total exchange balance GWh Σ 2010 5195

2011 6643

2006 0Consumption of pumps GWh Σ 2010 0

2011 0

2006 40629National electrical consumption, GWh Σ 2010 38976calculated to represent 100% of the national values 2011 40142

18.01.06 4767Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 3969calculated to represent 100% of the national values 16.02.11 3939

18.01.06 5871Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 5430calculated to represent 100% of the national values 16.02.11 5514

18.01.06 6271Highest load on the 3rd Wednesday, MW max. 15.12.10 5937

calculated to represent 100% of the national values 16.11.11 5705

18.01.06 16:00Time of highest load on the 3rd Wednesday CET 15.12.10 17:00

16.11.11 18:00

Page 65: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 65

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1H

un

gar

y

MM_YY

HU AT

HU CS

HU HR

HU RO

HU RS

HU SK

HU UA-W

Sum_ OF

AT HU

CS HU

HR HU

RO HU

RS HU

SK HU

UA-W HU

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

196

141

551

10

088

92

00

155

813

498

1468

579

II.06

138

114

549

00

080

13

10

152

739

447

1342

541

III.0

612

379

510

00

071

211

21

204

699

426

1343

631

IV.0

610

635

454

00

259

743

120

145

615

380

1195

598

V.0

611

268

330

40

251

625

100

164

604

413

1216

700

VI.0

662

8637

11

03

523

4911

013

565

034

711

9266

9V

II.06

1269

365

00

445

037

130

137

586

181

954

504

VIII

.06

181

133

327

00

064

126

00

138

696

344

1204

563

IX.0

658

127

334

20

052

151

40

9455

447

011

7365

2X

.06

3913

948

611

00

675

470

059

759

475

1340

665

XI.0

66

213

583

60

281

012

50

029

824

425

1403

593

XII.

0629

316

701

40

010

5046

00

2510

5344

515

6951

920

0610

6215

2055

6129

013

8185

465

531

1437

8592

4851

1539

972

14

I.10

1529

933

123

044

514

310

373

353

256

680

166

II.10

731

331

860

4247

935

027

237

321

565

217

3III

.10

520

330

610

8037

936

032

1644

710

763

825

9IV

.10

6913

812

60

1123

642

182

6351

783

788

552

V.1

060

4614

00

4816

883

1590

158

339

8977

460

6V

I.10

1690

35

047

161

115

1712

388

393

140

876

715

VII.

109

331

21

02

345

201

014

370

602

214

1230

885

VIII

.10

1434

29

150

1139

116

83

119

1853

996

943

552

IX.1

027

339

59

023

403

140

114

435

447

118

885

482

X.1

065

522

051

014

652

113

016

56

558

284

1126

474

XI.1

014

930

84

323

3352

937

411

426

280

241

702

173

XII.

1020

511

43

353

7144

913

5217

659

8621

760

315

420

1064

130

4514

639

256

426

4706

1014

9312

5254

449

3420

6098

9751

91

I.11

158

288

122

443

516

286

137

3336

526

583

431

8II.

1154

490

455

08

611

530

874

569

235

948

337

III.1

175

406

516

011

513

412

108

4851

624

195

644

3IV

.11

5932

05

120

039

648

214

854

573

213

1038

642

V.1

111

334

41

100

247

068

015

950

576

356

1209

739

VI.1

110

328

68

51

640

967

091

5143

531

696

055

1V

II.11

1446

737

210

654

522

10

3218

867

349

1487

942

VIII

.11

1160

649

600

1474

022

80

273

799

270

1327

587

IX.1

17

568

1343

09

640

321

050

465

235

613

8374

3X

.11

4156

542

600

070

817

80

203

853

396

1450

742

XI.1

123

845

8316

70

011

1819

10

60

869

390

1456

338

XII.

1139

984

9222

50

1213

5218

60

20

1046

385

1619

267

2011

697

6169

340

696

511

180

1816

3010

867

268

8120

3772

1466

766

49

Page 66: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

66 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationIreland

2006 n.a.hWGnoitareneg ten raelcun lamrehT 2010 0

2011 0

2006 n.a.hWGnoitareneg ten sleuf lissoF 2010 23025

2011 20417

2006 n.a.hWGnoitareneg ten ciluardyH 2010 726

2011 679

2006 n.a.hWG noitareneg ten elbawener rehtO 2010 2820

2011 4359

2006 n.a. - of which wind GWh 2010 2820

2011 4359

2006 n.a.- of which solar GWh 2010 0

2011 0

2006 n.a.hWGnoitareneg ten elbaifitnedi-noN 2010 248

2011 177

2006 n.a.hWG,noitareneg ten latoT 2010 1 26819

1102seulav lanoitan eht fo %001 tneserper ot detaluclac 1 25632

2006 n.a.hWGswolf edisni lacisyhp fo muS 2010 744

2011 733

2006 n.a.Sum of physical outside flows GWh 2010 293

2011 243

2006 n.a.hWGecnalab egnahcxe latoT 2010 469

2011 490

2006 n.a.hWGspmup fo noitpmusnoC 2010 287

2011 0

2006 n.a.hWG,noitpmusnoc lacirtcele lanoitaN 2010 27001

21621102seulav lanoitan eht fo %001 tneserper ot detaluclac 2

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 20.12.10 2906

78211.30.61seulav lanoitan eht fo %001 tneserper ot detaluclac 6

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 20.12.10 3960calculated to represent 100% of the national values 19.01.11 3882

n.a.Highest load on the 3rd Wednesday, MW max. 20.12.10 4664

calculated to represent 100% of the national values 19.01.11 4528

n.a.Time of highest load on the 3rd Wednesday CET 20.12.10 19:00

19.01.11 19:00

Page 67: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 67

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1Ir

elan

d

MM_YY

IE NI

Sum_ OF

NI IE

Sum_IF

Sum_IF - Sum_OF

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

II.06

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.IV

.06

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

6n.

a.n.

a.n.

a.n.

a.n.

a.V

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

06n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.IX

.06

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

6n.

a.n.

a.n.

a.n.

a.n.

a.X

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

06n.

a.n.

a.n.

a.n.

a.n.

a.20

06n

.a.

n.a

.n

.a.

n.a

.n

.a.

I.10

55

135

135

130

II.10

99

106

010

697

III.1

014

1472

072

58IV

.10

1919

500

5031

V.1

03

310

20

102

99V

I.10

1818

450

4527

VII.

1041

4124

024

-17

VIII

.10

1717

540

5437

IX.1

073

7315

015

-58

X.1

037

3723

023

-14

XI.1

048

4826

026

-22

XII.

109

992

092

8320

1029

329

374

474

445

1

I.11

1717

7171

54II.

1116

1665

6549

III.1

111

1192

9281

IV.1

13

313

013

012

7V

.11

99

108

108

99V

I.11

33

103

103

100

VII.

113

370

7067

VIII

.11

1818

5454

36IX

.11

2020

2424

4X

.11

3838

1010

-28

XI.1

148

483

3-4

5X

II.11

5757

33

-54

2011

243

243

733

733

490

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 68: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

68 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationCyprus

2006 n.a.Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 n.a.Fossil fuels net generation GWh Σ 2010 5202

2011 4833

2006 n.a.Hydraulic net generation GWh Σ 2010 0

2011 0

2006 n.a.Other renewable net generation GWh Σ 2010 33

2011 115

2006 n.a. - of which wind GWh Σ 2010 33

2011 115

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 n.a.Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 n.a.Total net generation, GWh Σ 2010 5235calculated to represent 100% of the national values 2011 4948

2006 n.a.Sum of physical inside flows GWh Σ 2010 0

2011 0

2006 n.a.Sum of physical outside flows GWh Σ 2010 0

2011 0

2006 n.a.Total exchange balance GWh Σ 2010 0

2011 0

2006 n.a.Consumption of pumps GWh Σ 2010 0

2011 0

2006 n.a.National electrical consumption, GWh Σ 2010 5235calculated to represent 100% of the national values 2011 4948

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. n.a.calculated to represent 100% of the national values n.a.

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. n.a.calculated to represent 100% of the national values n.a.

n.a.Highest load on the 3rd Wednesday, MW max. 18.08.11 983calculated to represent 100% of the national values 16.02.11 780

n.a.Time of highest load on the 3rd Wednesday CET 18.08.10 14:00

16.02.11 20:00

Page 69: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 69

Yearly values / OperationIceland

2006 0hWGnoitareneg ten raelcun lamrehT 2010 0

2011 0

2006 0hWGnoitareneg ten sleuf lissoF 2010 12

2011 8

2006 7044hWGnoitareneg ten ciluardyH 2010 12484

2011 12743

2006 2434hWG noitareneg ten elbawener rehtO 2010 4183

2011 4402

2006 0 - of which wind GWh 2010 0

2011 0

2006 n.a. - of which solar GWh 2010 0

2011 0

2006 4hWGnoitareneg ten elbaifitnedi-noN 2010 0

2011 0

2006 9482hWG,noitareneg ten latoT 2010 16679

51711102seulav lanoitan eht fo %001 tneserper ot detaluclac 3

2006 0hWGswolf edisni lacisyhp fo muS 2010 0

2011 0

2006 0Sum of physical outside flows GWh 2010 0

2011 0

2006 0hWGecnalab egnahcxe latoT 2010 0

2011 0

2006 0hWGspmup fo noitpmusnoC 2010 0

2011 0

2006 9482hWG,noitpmusnoc lacirtcele lanoitaN 2010 16679

51711102seulav lanoitan eht fo %001 tneserper ot detaluclac 3

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 20.12.10 1906

29111.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 9

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 20.12.10 2086calculated to represent 100% of the national values 19.01.11 2078

n.a.Highest load on the 3rd Wednesday, MW max. 20.12.10 2113

01211.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 1

n.a.Time of highest load on the 3rd Wednesday CET 20.12.10 19:00

21.12.11 19:00

Page 70: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

70 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationItaly

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 250685Fossil fuels net generation GWh Σ 2010 220938

2011 218457

2006 42450Hydraulic net generation GWh Σ 2010 53798

2011 47202

2006 8402Other renewable net generation GWh Σ 2010 15970

2011 25758

2006 3153 - of which wind GWh Σ 2010 9047

2011 9776

2006 n.a. - of which solar GWh Σ 2010 1875

2011 10670

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 301537Total net generation, GWh Σ 2010 290706calculated to represent 100% of the national values 2011 291417

2006 46525Sum of physical inside flows GWh Σ 2010 45899

2011 47478

2006 1618Sum of physical outside flows GWh Σ 2010 1699

2011 1715

2006 44907Total exchange balance GWh Σ 2010 44200

2011 45763

2006 8648Consumption of pumps GWh Σ 2010 4451

2011 2540

2006 337796National electrical consumption, GWh Σ 2010 330455calculated to represent 100% of the national values 2011 334640

19.07.06 33930Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 35755calculated to represent 100% of the national values 20.07.11 32905

19.07.06 53165Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 53959calculated to represent 100% of the national values 16.02.11 50005

18.01.06 53816Highest load on the 3rd Wednesday, MW max. 15.12.10 54927

calculated to represent 100% of the national values 21.12.11 51745

18.01.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 17:00

21.12.11 18:00

Page 71: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 71

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1Ita

ly

MM_YY

IT AT

IT CH

IT FR

IT GR

IT SI

Sum_ OF

AT IT

CH IT

FR IT

GR IT

SI IT

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

214

912

24

127

875

1058

694

169

418

2414

2136

II.06

112

910

30

123

489

1089

694

5047

723

9921

65III

.06

098

100

02

200

112

1412

1042

222

566

3354

3154

IV.0

60

036

30

3911

321

6416

1417

370

147

6547

26V

.06

02

420

044

140

2062

1439

149

591

4381

4337

VI.0

60

544

40

5311

321

7913

6619

520

4197

4144

VII.

060

2954

141

9813

121

1812

497

444

3949

3851

VIII

.06

02

3275

111

013

717

5686

04

289

3046

2936

IX.0

60

132

484

8511

422

3013

9534

204

3977

3892

X.0

60

536

691

111

133

2738

1619

5041

549

5548

44X

I.06

01

4710

01

149

124

2472

1546

4039

245

7444

25X

II.06

01

7813

80

217

134

2607

1373

2837

245

1442

9720

063

422

726

455

1216

1814

1523

885

1489

194

553

8946

525

4490

7

I.10

052

115

221

190

106

1686

811

312

727

3642

3452

II.10

027

751

510

810

219

0310

5720

077

540

3739

29III

.10

045

7715

714

411

921

8511

7120

686

245

4343

99IV

.10

044

8317

2817

211

221

2610

2071

726

4055

3883

V.1

00

6055

04

119

125

2003

861

069

736

8635

67V

I.10

065

3511

1012

111

919

5312

3041

580

3923

3802

VII.

100

2766

36

102

127

2503

1311

239

394

4574

4472

VIII

.10

29

9611

1213

093

1730

839

213

7229

4728

17IX

.10

017

481

672

104

1784

947

163

526

3524

3452

X.1

00

1611

15

1414

691

2043

867

282

610

3893

3747

XI.1

00

2787

65

125

118

1817

957

241

880

4013

3888

XII.

100

104

164

02

270

112

1443

512

331

664

3062

2792

2010

249

310

1272

120

1699

1328

2317

611

583

2299

7513

4589

944

200

I.11

040

138

50

183

9720

5811

1928

752

340

8439

01II.

110

1894

32

117

7823

2812

0616

843

042

1040

93III

.11

092

880

318

310

221

0812

6127

848

342

3240

49IV

.11

046

670

411

782

2053

1339

9648

740

5739

40V

.11

133

512

390

9318

0011

3110

341

435

4134

51V

I.11

082

5548

418

910

918

9710

9448

390

3538

3349

VII.

110

2156

132

9210

823

4310

7311

640

140

4139

49V

III.1

10

3686

417

143

115

2785

515

721

427

5426

11IX

.11

825

813

712

468

1690

925

104

315

3102

2978

X.1

10

1354

45

7611

226

8614

8511

044

448

3747

61X

I.11

014

6185

516

511

825

6315

0613

535

146

7345

08X

II.11

111

104

109

1123

610

425

5913

1399

334

4409

4173

2011

1043

193

527

663

1715

1072

2561

214

307

1701

4786

4747

845

763

Page 72: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

72 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationLithuania

2006 n.a.Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 n.a.Fossil fuels net generation GWh Σ 2010 3216

2011 2752

2006 n.a.Hydraulic net generation GWh Σ 2010 1196

2011 1049

2006 n.a.Other renewable net generation GWh Σ 2010 295

2011 620

2006 n.a. - of which wind GWh Σ 2010 193

2011 472

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 n.a.Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 n.a.Total net generation, GWh Σ 2010 1 5328calculated to represent 100% of the national values 2011 1 4421

2006 n.a.Sum of physical inside flows GWh Σ 2010 8177

2011 8086

2006 n.a.Sum of physical outside flows GWh Σ 2010 2185

2011 1345

2006 n.a.Total exchange balance GWh Σ 2010 5992

2011 6737

2006 n.a.Consumption of pumps GWh Σ 2010 1043

2011 796

2006 n.a.National electrical consumption, GWh Σ 2010 10276calculated to represent 100% of the national values 2011 10362

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1090calculated to represent 100% of the national values 16.02.11 1038

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1728calculated to represent 100% of the national values 21.12.11 1594

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 1787

calculated to represent 100% of the national values 21.12.11 1688

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 17:00

21.12.11 17:00

Page 73: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 73

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1L

ith

uan

ia

MM_YY

LT LV

LT BY

LT RU

Sum_ OF

LV LT

BY LT

RU LT

Sum_IF

Sum_IF - Sum_OF

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

II.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IV

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IX

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.X

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.20

06n

.a.

n.a

.n

.a.

n.a

.n

.a.

n.a

.n

.a.

n.a

.n

.a.

I.10

5823

246

327

181

431

5266

433

7II.

1062

3617

527

313

932

581

545

272

III.1

023

3112

417

821

730

857

582

404

IV.1

00

7320

928

253

924

36

788

506

V.1

018

3310

615

725

539

135

681

524

VI.1

08

1646

7023

029

569

594

524

VII.

108

2273

103

177

384

8364

454

1V

III.1

020

3773

130

214

382

7867

454

4IX

.10

429

129

162

226

453

5873

757

5X

.10

2935

104

168

202

509

3674

757

9X

I.10

336

109

148

309

342

4269

354

5X

II.10

131

155

187

366

425

3782

864

120

1023

440

215

4921

8530

5544

8863

481

7759

92

I.11

342

4085

309

256

100

665

580

II.11

347

3686

282

223

9159

651

0III

.11

1058

1583

243

213

145

601

518

IV.1

10

159

1617

553

476

112

722

547

V.1

15

784

8738

321

514

574

365

6V

I.11

4595

014

022

314

531

067

853

8V

II.11

1096

010

621

714

832

869

358

7V

III.1

153

382

9311

127

930

069

059

7IX

.11

7337

1512

569

321

240

630

505

X.1

110

224

2014

610

045

716

772

457

8X

I.11

7032

210

413

234

325

472

962

5X

II.11

6941

511

513

124

024

461

550

020

1144

374

715

513

4527

3429

1624

3680

8667

41

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 74: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

74 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationLuxembourg

2006 0hWGnoitareneg ten raelcun lamrehT 2010 0

2011 0

2006 3195hWGnoitareneg ten sleuf lissoF 2010 2879

2011 2318

2006 892hWGnoitareneg ten ciluardyH 2010 1458

2011 1127

2006 122hWG noitareneg ten elbawener rehtO 2010 178

2011 216

2006 60 - of which wind GWh 2010 55

2011 64

2006 n.a.- of which solar GWh 2010 0

2011 8

2006 0hWGnoitareneg ten elbaifitnedi-noN 2010 0

2011 0

2006 4209hWG,noitareneg ten latoT 2010 4515

6631102seulav lanoitan eht fo %001 tneserper ot detaluclac 1

2006 6831hWGswolf edisni lacisyhp fo muS 2010 7282

2011 7099

2006 3286Sum of physical outside flows GWh 2010 3208

2011 2657

2006 3546hWGecnalab egnahcxe latoT 2010 4074

2011 4407

2006 1139hWGspmup fo noitpmusnoC 2010 1899

2011 1510

2006 6616hWG,noitpmusnoc lacirtcele lanoitaN 2010 6690

5561102seulav lanoitan eht fo %001 tneserper ot detaluclac 8

15.03.06 792Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 19.01.10 779calculated to represent 100% of the national values 16.02.11 816

18.10.06 936Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 19.01.10 1021

70111.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 8

18.01.06 972Highest load on the 3rd Wednesday, MW max. 15.12.10 1047

81111.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 8

18.01.06 19:00Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

21.12.11 18:00

Page 75: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 75

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1L

uxe

mb

ou

rg

MM_YY

LU BE

LU DE

Sum_ OF

BE LU

DE LU

Sum_IF

Sum_IF - Sum_OF

Bal

ance

I.06

222

6929

114

746

661

332

2II.

0613

061

191

127

416

543

352

III.0

622

764

291

147

442

589

298

IV.0

620

167

268

139

406

545

277

V.0

622

376

299

162

426

588

289

VI.0

623

972

311

161

416

577

266

VII.

0622

667

293

179

440

619

326

VIII

.06

192

6025

285

392

477

225

IX.0

620

265

267

132

422

554

287

X.0

618

672

258

146

447

593

335

XI.0

620

864

272

143

434

577

305

XII.

0622

667

293

129

427

556

263

2006

2482

804

3286

1697

5134

6831

3545

I.10

160

116

276

9654

263

836

2II.

1015

310

425

788

486

574

317

III.1

015

710

326

010

451

161

535

5IV

.10

142

129

271

108

518

626

355

V.1

010

215

525

713

356

269

543

8V

I.10

160

111

271

7350

758

030

9V

II.10

154

8223

610

048

258

234

6V

III.1

015

277

229

5243

548

725

8IX

.10

145

8923

410

347

057

333

9X

.10

173

109

282

108

521

629

347

XI.1

015

413

829

299

546

645

353

XII.

1019

514

834

359

579

638

295

2010

1847

1361

3208

1123

6159

7282

4074

I.11

169

140

309

112

567

679

370

II.11

157

139

296

101

540

641

345

III.1

116

619

736

310

056

666

630

3IV

.11

155

123

278

9951

561

433

6V

.11

154

4920

312

444

056

436

1V

I.11

171

017

112

334

246

529

4V

II.11

144

4719

113

841

355

136

0V

III.1

114

7993

111

452

563

470

IX.1

10

7979

157

471

628

549

X.1

136

101

137

107

512

619

482

XI.1

118

680

266

7948

256

129

5X

II.11

181

9027

169

479

548

277

2011

1533

1124

2657

1320

5779

7099

4442

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)

Page 76: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

76 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationLatvia

2006 n.a.Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 n.a.Fossil fuels net generation GWh Σ 2010 2847

2011 2885

2006 n.a.Hydraulic net generation GWh Σ 2010 3496

2011 2870

2006 n.a.Other renewable net generation GWh Σ 2010 101

2011 183

2006 n.a. - of which wind GWh Σ 2010 47

2011 72

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 n.a.Non-identifiable net generation GWh Σ 2010 0

2011 219

2006 n.a.Total net generation, GWh Σ 2010 6444calculated to represent 100% of the national values 2011 6157

2006 n.a.Sum of physical inside flows GWh Σ 2010 3973

2011 4010

2006 n.a.Sum of physical outside flows GWh Σ 2010 3101

2011 2760

2006 n.a.Total exchange balance GWh Σ 2010 872

2011 1107

2006 n.a.Consumption of pumps GWh Σ 2010 0

2011 0

2006 n.a.National electrical consumption, GWh Σ 2010 7316calculated to represent 100% of the national values 2011 7264

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 20.01.10 731calculated to represent 100% of the national values 16.02.11 742

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 20.01.10 1169calculated to represent 100% of the national values 16.02.11 1130

n.a.Highest load on the 3rd Wednesday, MW max. 20.01.10 1257

calculated to represent 100% of the national values 16.02.11 1226

n.a.Time of highest load on the 3rd Wednesday CET 20.01.10 17:00

16.02.11 9:00

Page 77: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 77

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1L

atvi

a

MM_YY

LV EE

LV LT

LV RU

Sum_ OF

EE LV

LT LV

RU LV

Sum_IF

Sum_IF - Sum_OF

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

II.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IV

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IX

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.X

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.20

06n

.a.

n.a

.n

.a.

n.a

.n

.a.

n.a

.n

.a.

n.a

.n

.a.

I.10

818

13

192

116

5839

213

21II.

101

139

014

012

662

4823

696

III.1

013

217

423

412

623

4519

4-4

0IV

.10

1553

91

555

900

4813

8-4

17V

.10

125

50

256

151

1842

211

-45

VI.1

00

230

023

023

28

9133

110

1V

II.10

017

70

177

337

813

848

330

6V

III.1

00

214

021

428

420

127

431

217

IX.1

00

226

022

631

44

128

446

220

X.1

00

202

020

232

329

6942

121

9X

I.10

030

90

309

251

311

136

556

XII.

100

366

036

634

51

158

504

138

2010

3830

558

3101

2695

234

1044

3973

872

I.11

030

90

309

207

395

305

-4II.

110

282

028

217

63

8926

8-1

4III

.11

224

30

245

142

1080

232

-13

IV.1

122

534

055

674

068

142

-414

V.1

10

383

038

317

95

9628

0-1

03V

I.11

022

30

223

290

4511

044

522

2V

II.11

021

70

217

347

1013

248

927

2V

III.1

10

111

011

124

453

7837

526

4IX

.11

269

071

265

7375

413

342

X.1

10

100

010

031

710

221

440

340

XI.1

10

132

013

223

970

4235

121

9X

II.11

013

10

131

153

6948

270

139

2011

2627

340

2760

2633

443

934

4010

1250

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 78: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

78 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationMontenegro

Thermal nuclear net generation GWh Σ 2010 02011 0

Fossil fuels net generation GWh Σ 2010 12672011 1446

Hydraulic net generation GWh Σ 2010 27382011 1186

Other renewable net generation GWh Σ 2010 02011 0

- of which wind GWh Σ 2010 02011 0

- of which solar GWh Σ 2010 02011 0

Non-identifiable net generation GWh Σ 2010 02011 0

Total net generation, GWh Σ 2010 4005calculated to represent 100% of the national values 2011 2632

Sum of physical inside flows GWh Σ 2010 23332011 1 3416

Sum of physical outside flows GWh Σ 2010 23832011 1 900

Total exchange balance GWh Σ 2010 392011 1551

Consumption of pumps GWh Σ 2010 02011 0

National electrical consumption, GWh Σ 2010 4044calculated to represent 100% of the national values 2011 4183

Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 20.01.10 427calculated to represent 100% of the national values 21.12.11 449

Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 16.02.10 532calculated to represent 100% of the national values 21.12.11 575

Highest load on the 3rd Wednesday, MW max. 20.01.10 589

calculated to represent 100% of the national values 21.12.11 648

Time of highest load on the 3rd Wednesday CET 20.01.10 19:0021.12.11 19:00

1 Sum of physical inside and outside flows without ME - AL

Page 79: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 79

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1M

on

ten

egro

MM_YY

ME BA

ME RS

ME AL

Sum_ OF

BA ME

RS ME

AL ME

Sum_IF

Sum_IF - Sum_OF

I.06

II.06

III.0

6IV

.06

V.0

6V

I.06

VII.

06V

III.0

6IX

.06

X.0

6X

I.06

XII.

0620

06 I.10

4630

151

398

258

20

260

-138

II.10

4416

624

234

181

120

193

-41

III.1

050

196

2927

517

810

519

3-8

2IV

.10

5711

22

171

6118

3811

7-5

4V

.10

5513

061

246

7418

698

-148

VI.1

089

751

165

7710

3712

4-4

1V

II.10

3334

3510

215

592

024

714

5V

III.1

010

1982

111

210

930

303

192

IX.1

026

440

7013

910

60

245

175

X.1

042

749

125

6295

6221

994

XI.1

078

104

218

470

4648

164

-20

XII.

1098

195

930

213

29

2917

0-1

3220

1062

814

5030

523

8315

9751

122

523

33-5

0

I.11

6115

1n.

a.n.

a.15

622

n.a.

00

II.11

4379

n.a.

n.a.

149

42n.

a.0

0III

.11

4249

n.a.

n.a.

133

87n.

a.0

0IV

.11

6718

n.a.

n.a.

6615

3n.

a.0

0V

.11

746

n.a.

n.a.

4324

4n.

a.0

0V

I.11

4617

n.a.

n.a.

5422

6n.

a.0

0V

II.11

2911

n.a.

n.a.

122

199

n.a.

00

VIII

.11

921

n.a.

n.a.

206

133

n.a.

00

IX.1

110

19n.

a.n.

a.16

812

9n.

a.0

0X

.11

1836

n.a.

n.a.

134

98n.

a.0

0X

I.11

330

n.a.

n.a.

277

131

n.a.

00

XII.

115

56n.

a.n.

a.31

313

1n.

a.0

020

1140

749

3n

.a.

n.a

.18

2115

95n

.a.

n.a

.n

.a.

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 80: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

80 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationFYROM

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 4940Fossil fuels net generation GWh Σ 2010 4282

2011 4858

2006 1624Hydraulic net generation GWh Σ 2010 2316

2011 1469

2006 0Other renewable net generation GWh Σ 2010 0

2011 0

2006 0 - of which wind GWh Σ 2010 0

2011 0

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 6564Total net generation, GWh Σ 2010 6598calculated to represent 100% of the national values 2011 6327

2006 2998Sum of physical inside flows GWh Σ 2010 5270

2011 4169

2006 1202Sum of physical outside flows GWh Σ 2010 3857

2011 1548

2006 1813Total exchange balance GWh Σ 2010 1730

2011 2659

2006 0Consumption of pumps GWh Σ 2010 0

2011 0

2006 8377National electrical consumption, GWh Σ 2010 8328calculated to represent 100% of the national values 2011 8986

15.02.06 1088Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1087calculated to represent 100% of the national values 19.01.11 1058

18.01.06 1415Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1357calculated to represent 100% of the national values 16.02.11 1254

18.01.06 1520Highest load on the 3rd Wednesday, MW max. 15.12.10 1535

calculated to represent 100% of the national values 21.12.11 1486

18.01.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

21.12.11 15:00

Page 81: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 81

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1FY

RO

M

MM_YY

MK BG

MK CS

MK GR

MK RS

Sum_ OF

BG MK

CS MK

GR MK

GR RS

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)

I.06

00

5656

7820

31

282

226

II.06

00

5858

7320

81

282

224

III.0

60

011

711

768

210

027

816

1IV

.06

00

127

127

6517

10

236

109

V.0

60

011

911

946

198

024

412

5V

I.06

00

109

109

9215

11

244

135

VII.

060

018

118

169

178

024

766

VIII

.06

00

110

110

7816

60

244

134

IX.0

60

080

8072

175

124

816

8X

.06

00

7979

7185

816

485

XI.0

60

010

110

172

191

026

316

2X

II.06

00

6565

7619

00

266

201

2006

00

1202

1202

860

2126

1229

9817

96

I.10

028

60

286

183

022

440

712

1II.

100

312

031

220

20

188

390

78III

.10

035

70

357

198

029

148

913

2IV

.10

035

60

356

171

020

637

721

V.1

00

359

035

913

90

191

330

-29

VI.1

00

507

050

725

80

203

461

-46

VII.

100

502

050

238

70

163

550

48V

III.1

00

481

048

141

20

222

634

153

IX.1

00

308

030

831

40

161

475

167

X.1

00

120

012

021

66

139

361

241

XI.1

00

128

012

824

51

135

381

253

XII.

100

141

014

122

81

186

415

274

2010

038

570

3857

2953

823

0952

7014

13

I.11

015

30

153

233

020

243

528

2II.

110

173

017

325

30

133

386

213

III.1

10

212

021

224

40

140

384

172

IV.1

10

134

013

424

53

825

612

2V

.11

085

2511

021

919

924

713

7V

I.11

012

32

125

224

373

300

175

VII.

110

208

020

828

10

157

438

230

VIII

.11

023

21

233

230

017

440

417

1IX

.11

041

1253

254

1666

336

283

X.1

10

621

6319

09

6326

219

9X

I.11

023

1336

267

3560

362

326

XII.

110

435

4827

822

5935

931

120

110

1489

5915

4829

1810

711

4441

6926

21

Bal

ance

Page 82: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

82 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationGB Northern Ireland

2006 n.a.Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 n.a.Fossil fuels net generation GWh Σ 2010 6581

2011 6636

2006 0Hydraulic net generation GWh Σ 2010 8

2011 7

2006 n.a.Other renewable net generation GWh Σ 2010 724

2011 1063

2006 n.a. - of which wind GWh Σ 2010 666

2011 1005

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 n.a.Non-identifiable net generation GWh Σ 2010 12

2011 18

2006 n.a.Total net generation, GWh Σ 2010 7325calculated to represent 100% of the national values 2011 7724

2006 n.a.Sum of physical inside flows GWh Σ 2010 2592

2011 2012

2006 n.a.Sum of physical outside flows GWh Σ 2010 744

2011 733

2006 n.a.Total exchange balance GWh Σ 2010 1855

2011 1285

2006 n.a.Consumption of pumps GWh Σ 2010 0

2011 0

2006 n.a.National electrical consumption, GWh Σ 2010 9180calculated to represent 100% of the national values 2011 9009

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 938calculated to represent 100% of the national values 19.01.11 903

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1488calculated to represent 100% of the national values 19.01.11 1457

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 1684

calculated to represent 100% of the national values 19.01.11 1681

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

19.01.11 19:00

Page 83: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 83

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1G

B N

ort

her

n Ir

elan

d

MM_YY

NI GB

NI IE

Sum_ OF

GB NI

IE NI

Sum_IF

Sum_IF - Sum_OF

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

II.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IV

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.IX

.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

6n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.X

I.06

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

06n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.n.

a.20

06n

.a.

n.a

.n

.a.

n.a

.n

.a.

n.a

.n

.a.

I.10

013

513

523

55

240

105

II.10

010

610

621

89

227

121

III.1

00

7272

248

1426

219

0IV

.10

050

5019

019

209

159

V.1

00

102

102

223

322

612

4V

I.10

045

4582

1810

055

VII.

100

2424

155

4119

617

2V

III.1

00

5454

220

1723

718

3IX

.10

015

1513

473

207

192

X.1

00

2323

139

3717

615

3X

I.10

026

2616

548

213

187

XII.

100

9292

290

929

920

720

100

744

744

2299

293

2592

1848

I.11

071

7130

017

317

246

II.11

065

6523

516

251

186

III.1

10

9292

262

1127

318

1IV

.11

013

013

023

23

235

105

V.1

10

108

108

242

925

114

3V

I.11

010

310

323

53

238

135

VII.

110

7070

154

315

787

VIII

.11

054

5410

918

127

73IX

.11

024

240

2020

-4X

.11

010

100

3838

28X

I.11

03

30

4848

45X

II.11

03

30

5757

5420

110

733

733

1769

243

2012

1279

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 84: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

84 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationThe Netherlands

2006 3269hWGnoitareneg ten raelcun lamrehT 2010 3755

2011 3919

2006 84278hWGnoitareneg ten sleuf lissoF 2010 99539

2011 93002

2006 100hWGnoitareneg ten ciluardyH 2010 0

2011 0

2006 7067hWG noitareneg ten elbawener rehtO 2010 10391

2011 12104

2006 2697 - of which wind GWh 2010 3995

2011 5096

2006 n.a.- of which solar GWh 2010 0

2011 0

2006 0hWGnoitareneg ten elbaifitnedi-noN 2010 0

2011 0

2006 1 94714hWG,noitareneg ten latoT 2010 1 113685

1102seulav lanoitan eht fo %001 tneserper ot detaluclac 1 109025

2006 27355hWGswolf edisni lacisyhp fo muS 2010 15589

2011 20665

2006 5886Sum of physical outside flows GWh 2010 12811

2011 11787

2006 21465hWGecnalab egnahcxe latoT 2010 2775

2011 8812

2006 0hWGspmup fo noitpmusnoC 2010 0

2011 0

2006 116179hWG,noitpmusnoc lacirtcele lanoitaN 2010 116460

387111102seulav lanoitan eht fo %001 tneserper ot detaluclac 7

20.12.06 11582Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 10605calculated to represent 100% of the national values 16.11.11 10183

20.12.06 17796Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 17219

946111.21.12seulav lanoitan eht fo %001 tneserper ot detaluclac 6

20.12.06 17855Highest load on the 3rd Wednesday, MW max. 15.12.10 18187

437111.11.61seulav lanoitan eht fo %001 tneserper ot detaluclac 6

20.12.06 10:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

16.11.11 18:00

Page 85: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 85

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1T

he

Net

her

lan

ds

MM_YY

NL BE

NL DE

NL GB

NL NO

Sum_ OF

BE NL

DE NL

GB NL

NO NL

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.06

888

088

864

2486

2550

1662

II.06

1118

011

1829

2322

2351

1233

III.0

612

750

1275

2727

5927

8615

11IV

.06

419

041

941

221

1325

2521

06V

.06

323

132

444

320

3124

7421

50V

I.06

190

819

877

115

6423

3521

37V

II.06

137

3517

280

111

7819

7918

07V

III.0

66

214

220

860

929

1789

1569

IX.0

675

2297

790

1115

1905

1808

X.0

612

02

122

521

1478

1999

1877

XI.0

630

30

303

222

1986

2208

1905

XII.

0674

91

750

7923

7524

5417

0420

0656

0328

358

8650

1922

336

2735

521

469

I.10

947

239

242

1428

111

643

115

869

-559

II.10

670

247

091

725

841

00

668

-249

III.1

062

355

50

1178

326

362

068

8-4

90IV

.10

456

114

5862

826

488

12

1147

519

V.1

058

620

927

410

6942

810

3611

415

7850

9V

I.10

326

191

231

748

745

920

153

1818

1070

VII.

1024

613

819

357

784

194

320

619

9014

13V

III.1

018

329

124

071

411

6857

616

019

0411

90IX

.10

392

327

207

926

571

584

169

1324

398

X.1

010

6748

120

017

4820

033

024

077

0-9

78X

I.10

828

210

298

1336

282

707

125

1114

-222

XII.

1010

6870

404

1542

124

1550

4517

1917

720

1073

9230

7223

4712

811

5318

8942

1329

1558

927

78

I.11

559

110

470

1040

292

1578

029

1899

859

II.11

425

610

405

891

212

1022

019

1253

362

III.1

148

486

044

410

1440

198

90

2314

1339

9IV

.11

235

228

299

182

944

586

730

2875

1419

475

V.1

111

854

281

074

187

827

975

012

3249

1V

I.11

8525

031

030

675

1011

795

6732

121

9415

19V

II.11

144

309

402

085

511

0968

826

490

2313

1458

VIII

.11

181

424

397

010

0211

1055

551

507

2223

1221

IX.1

124

339

623

70

876

804

588

107

430

1929

1053

X.1

167

332

119

70

1191

240

764

9650

016

0040

9X

I.11

639

427

121

011

8718

759

421

949

214

9230

5X

II.11

735

166

450

2013

7118

010

0737

474

1698

327

2011

4521

3221

2494

1551

1178

770

1095

8970

633

6020

665

8878

Page 86: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

86 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationNorway

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 1123Fossil fuels net generation GWh Σ 2010 5267

2011 4776

2006 119919Hydraulic net generation GWh Σ 2010 117286

2011 121383

2006 673Other renewable net generation GWh Σ 2010 892

2011 1257

2006 673 - of which wind GWh Σ 2010 808

2011 1257

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 121715Total net generation, GWh Σ 2010 1 123445calculated to represent 100% of the national values 2011 1 127416

2006 n.a.Sum of physical inside flows GWh Σ 2010 14441

2011 11022

2006 n.a.Sum of physical outside flows GWh Σ 2010 6593

2011 13600

2006 857Total exchange balance GWh Σ 2010 7537

2011 -2986

2006 540Consumption of pumps GWh Σ 2010 1190

2011 2410

2006 122032National electrical consumption, GWh Σ 2010 129792calculated to represent 100% of the national values 2011 122020

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 17165calculated to represent 100% of the national values 16.02.11 17235

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 21350calculated to represent 100% of the national values 16.02.11 21189

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 21852

calculated to represent 100% of the national values 16.02.11 21512

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 10:00

16.02.11 9:00

Page 87: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 87

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1N

orw

ay

MM_YY

NO DK_W

NO DK

NO FI

NO NL

NO SE

NO RU

Sum_ OF

DK_W NO

DK NO

FI NO

NL NO

SE NO

RU NO

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)

I.06

269

n.a.

n.a.

n.a.

n.a.

84n.

a.n.

a.n.

a.n.

a.n.

a.II.

0614

5n.

a.n.

a.n.

a.n.

a.50

n.a.

n.a.

n.a.

n.a.

n.a.

III.0

678

n.a.

n.a.

n.a.

n.a.

179

n.a.

n.a.

n.a.

n.a.

n.a.

IV.0

630

n.a.

n.a.

n.a.

n.a.

261

n.a.

n.a.

n.a.

n.a.

n.a.

V.0

653

n.a.

n.a.

n.a.

n.a.

203

n.a.

n.a.

n.a.

n.a.

n.a.

VI.0

687

n.a.

n.a.

n.a.

n.a.

180

n.a.

n.a.

n.a.

n.a.

n.a.

VII.

0614

3n.

a.n.

a.n.

a.n.

a.13

8n.

a.n.

a.n.

a.n.

a.n.

a.V

III.0

629

n.a.

n.a.

n.a.

n.a.

254

n.a.

n.a.

n.a.

n.a.

n.a.

IX.0

632

n.a.

n.a.

n.a.

n.a.

240

n.a.

n.a.

n.a.

n.a.

n.a.

X.0

657

n.a.

n.a.

n.a.

n.a.

236

n.a.

n.a.

n.a.

n.a.

n.a.

XI.0

678

n.a.

n.a.

n.a.

n.a.

196

n.a.

n.a.

n.a.

n.a.

n.a.

XII.

0612

6n.

a.n.

a.n.

a.n.

a.30

3n.

a.n.

a.n.

a.n.

a.n.

a.20

0611

2715

076

670

8944

2324

8471

7821

598

0185

7

I.10

130

311

550

80

756

384

1424

229

420

954

198

II.10

490

032

30

372

479

210

400

1791

754

5III

.10

20

012

00

122

629

400

721

1714

0712

85IV

.10

340

269

010

542

036

5810

7515

1604

1499

V.1

012

49

114

300

277

337

1327

413

8821

2033

1756

VI.1

011

74

153

510

325

243

523

112

6917

1765

1440

VII.

1027

738

206

396

091

716

35

193

449

2083

0-8

7V

III.1

020

424

160

177

056

515

50

240

504

1191

034

5IX

.10

214

2116

937

80

782

159

020

735

017

733

-49

X.1

018

411

240

871

013

0624

11

200

294

1675

2-5

54X

I.10

892

125

368

058

435

217

298

510

1811

9561

1X

II.10

343

4540

00

482

493

1040

441

420

1341

859

2010

1458

115

1329

3691

065

9340

5516

223

4776

6820

914

441

7848

I.11

61

2923

059

599

1547

012

7717

2378

2319

II.11

81

1956

084

535

2240

597

919

1960

1876

III.1

110

023

320

6558

635

444

1157

1122

3321

68IV

.11

156

175

114

034

630

419

182

1042

1715

6412

18V

.11

203

120

197

041

219

03

058

520

798

386

VI.1

117

333

321

739

012

6619

030

227

2930

5-9

61V

II.11

531

3349

012

860

2340

00

070

1888

-225

2V

III.1

163

26

507

1040

021

856

50

107

1713

5-2

050

IX.1

156

16

430

720

017

170

50

337

1435

6-1

361

X.1

151

719

500

789

018

259

00

190

1121

0-1

615

XI.1

150

619

492

1034

020

5112

00

120

1915

1-1

900

XII.

1129

70

474

479

012

5015

423

2062

720

844

-406

2011

3600

131

3360

6509

013

600

2414

127

1551

6718

212

1102

2-2

578

Bal

ance

Page 88: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

88 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationPoland

2 Since 2011 other renewable has included energy from biomass co-firing in conventional thermal units, previously classified

as fossil fuel generation category.

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 145736Fossil fuels net generation GWh Σ 2010 140270

2011 2 140894

2006 2794Hydraulic net generation GWh Σ 2010 3405

2011 2647

2006 326Other renewable net generation GWh Σ 2010 2108

2011 2 8069

2006 234 - of which wind GWh Σ 2010 1843

2011 2745

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 148856Total net generation, GWh Σ 2010 1 145783calculated to represent 100% of the national values 2011 1 151610

2006 4771Sum of physical inside flows GWh Σ 2010 6314

2011 6779

2006 15777Sum of physical outside flows GWh Σ 2010 7659

2011 12023

2006 -11001Total exchange balance GWh Σ 2010 -1355

2011 -5244

2006 1357Consumption of pumps GWh Σ 2010 837

2011 464

2006 136498National electrical consumption, GWh Σ 2010 143591calculated to represent 100% of the national values 2011 145720

18.01.06 15648Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 15742calculated to represent 100% of the national values 16.02.11 15406

18.01.06 20419Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 21538calculated to represent 100% of the national values 21.12.11 21031

20.12.06 22017Highest load on the 3rd Wednesday, MW max. 15.12.10 23081

calculated to represent 100% of the national values 21.12.11 22697

20.12.06 17:00Time of highest load on the 3rd Wednesday CET 15.12.10 17:00

21.12.11 18:00

Page 89: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 89

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1P

ola

nd

MM_YY

PL CZ

PL DE

PL SE

PL SK

PL BY

PL UA

Sum_ OF

CZ PL

DE PL

SE PL

SK PL

BY PL

UA PL

Sum_IF

Sum_IF - Sum_OF

Out

sid

e fl

ow

s (O

F)

Insi

de fl

ows

(IF

)

I.06

1174

925

536

10

017

990

303

00

9881

482

-131

7II.

0610

437

199

385

00

1634

027

90

090

7844

7-1

187

III.0

610

2513

229

307

00

1574

123

10

010

274

408

-116

6IV

.06

831

9424

228

10

014

481

560

083

4818

8-1

260

V.0

678

144

4525

00

011

208

120

102

086

7839

4-7

26V

I.06

584

212

5119

90

010

468

1196

083

6926

7-7

79V

II.06

558

102

1915

90

083

810

153

514

8874

380

-458

VIII

.06

538

133

6819

00

758

1278

20

4572

209

-549

IX.0

669

577

121

310

00

1203

188

00

7381

243

-960

X.0

686

630

6640

20

013

640

287

00

102

8847

7-8

87X

I.06

1043

111

231

50

014

711

411

00

9662

570

-901

XII.

0610

430

9338

60

015

220

531

130

9765

706

-816

2006

1018

172

215

0033

740

015

777

4225

4826

44

1043

870

4771

-110

06

I.10

521

374

147

00

745

454

826

40

058

2-1

63II.

1064

30

8918

70

091

92

584

00

00

586

-333

III.1

051

10

7422

00

080

54

622

211

00

648

-157

IV.1

045

10

1216

80

063

13

584

932

00

682

51V

.10

360

105

990

047

418

360

232

100

062

014

6V

I.10

260

420

630

036

525

161

6620

00

272

-93

VII.

1044

25

717

90

063

38

525

160

00

069

360

VIII

.10

322

252

870

043

614

405

786

00

503

67IX

.10

416

1644

10

047

728

254

58

00

295

-182

X.1

061

81

4917

60

084

411

513

360

00

560

-284

XI.1

055

016

5912

60

075

15

466

391

00

511

-240

XII.

1040

649

7945

00

579

1431

25

310

036

2-2

1720

1055

0016

749

414

980

076

5913

653

3476

183

00

6314

-134

5

I.11

440

7159

760

064

610

207

113

00

231

-415

II.11

582

1442

202

00

840

639

915

00

042

0-4

20III

.11

698

7256

254

00

1080

529

18

10

030

5-7

75IV

.11

580

2736

170

00

813

631

987

30

041

5-3

98V

.11

514

121

5216

60

085

36

160

113

30

028

2-5

71V

I.11

473

779

125

00

684

621

916

66

00

397

-287

VII.

1186

64

214

90

010

211

630

252

00

088

3-1

38V

III.1

182

116

218

80

010

273

413

210

00

062

6-4

01IX

.11

577

222

324

00

925

231

916

50

00

486

-439

X.1

177

26

039

50

011

730

636

480

025

709

-464

XI.1

192

13

748

60

014

170

712

163

00

3490

9-5

08X

II.11

1009

011

519

00

1539

083

328

60

00

1119

-420

2011

8253

433

278

3054

00

1201

845

5138

1514

260

5967

82-5

236

Bal

ance

Page 90: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

90 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationPortugal

2006 0Thermal nuclear net generation GWh Σ 2010 0

2011 0

2006 28423Fossil fuels net generation GWh Σ 2010 22315

2011 24732

2006 11198Hydraulic net generation GWh Σ 2010 16247

2011 11825

2006 4818Other renewable net generation GWh Σ 2010 11530

2011 11866

2006 2892 - of which wind GWh Σ 2010 9023

2011 9002

2006 n.a. - of which solar GWh Σ 2010 207

2011 262

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 45968Total net generation, GWh Σ 2010 1 50092calculated to represent 100% of the national values 2011 1 48423

2006 8481Sum of physical inside flows GWh Σ 2010 5667

2011 6685

2006 3183Sum of physical outside flows GWh Σ 2010 3190

2011 3928

2006 5441Total exchange balance GWh Σ 2010 2624

2011 2813

2006 704Consumption of pumps GWh Σ 2010 510

2011 737

2006 50705National electrical consumption, GWh Σ 2010 52206calculated to represent 100% of the national values 2011 50499

20.12.06 5511Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 5350calculated to represent 100% of the national values 16.02.11 5430

18.01.06 7857Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 17.02.10 7849calculated to represent 100% of the national values 16.02.11 7685

20.12.06 9048Highest load on the 3rd Wednesday, MW max. 17.02.10 8800

calculated to represent 100% of the national values 16.02.11 8575

20.12.06 20:00Time of highest load on the 3rd Wednesday CET 17.02.10 21:00

16.02.11 21:00

Page 91: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 91

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1P

ort

ug

al

MM_YY

PT ES

Sum_ OF

ES PT

Sum_IF

Sum_IF - Sum_OF

I.06

223

223

914

914

691

II.06

251

251

806

806

555

III.0

633

033

082

482

449

4IV

.06

271

271

541

541

270

V.0

619

619

672

772

753

1V

I.06

151

151

812

812

661

VII.

0625

425

477

577

552

1V

III.0

629

929

964

364

334

4IX

.06

110

110

808

808

698

X.0

625

825

878

378

352

5X

I.06

357

357

502

502

145

XII.

0648

348

334

634

6-1

3720

0631

8331

8384

8184

8152

98

I.10

617

617

336

336

-281

II.10

350

350

416

416

66III

.10

358

358

385

385

27IV

.10

287

287

323

323

36V

.10

291

291

345

345

54V

I.10

122

122

534

534

412

VII.

1010

010

067

167

157

1V

III.1

080

8069

169

161

1IX

.10

8787

603

603

516

X.1

070

7068

968

961

9X

I.10

232

232

456

456

224

XII.

1059

659

621

821

8-3

7820

1031

9031

9056

6756

6724

77

I.11

465

465

499

499

34II.

1146

146

128

928

9-1

72III

.11

488

488

498

498

10IV

.11

197

197

697

697

500

V.1

143

643

638

638

6-5

0V

I.11

224

224

542

542

318

VII.

1124

024

067

467

443

4V

III.1

130

130

158

058

027

9IX

.11

231

231

677

677

446

X.1

125

525

559

759

734

2X

I.11

338

338

526

526

188

XII.

1129

229

272

072

042

820

1139

2839

2866

8566

8527

57

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 92: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

92 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationRomania

2006 5204Thermal nuclear net generation GWh Σ 2010 10686

2011 10796

2006 34236Fossil fuels net generation GWh Σ 2010 25284

2011 30099

2006 17982Hydraulic net generation GWh Σ 2010 20174

2011 14670

2006 0Other renewable net generation GWh Σ 2010 402

2011 1403

2006 0 - of which wind GWh Σ 2010 290

2011 1218

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 57422Total net generation, GWh Σ 2010 56546calculated to represent 100% of the national values 2011 56968

2006 1635Sum of physical inside flows GWh Σ 2010 1791

2011 2946

2006 5884Sum of physical outside flows GWh Σ 2010 4707

2011 4846

2006 -4252Total exchange balance GWh Σ 2010 -2919

2011 -1899

2006 154Consumption of pumps GWh Σ 2010 265

2011 153

2006 53016National electrical consumption, GWh Σ 2010 53362calculated to represent 100% of the national values 2011 54916

18.01.06 6226Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 5856calculated to represent 100% of the national values 16.02.11 6043

18.01.06 7772Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 7662calculated to represent 100% of the national values 16.02.11 7889

20.12.06 7974Highest load on the 3rd Wednesday, MW max. 15.12.10 8313

calculated to represent 100% of the national values 16.02.11 8447

20.12.06 18:00Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

16.02.11 19:00

Page 93: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 93

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1R

om

ania

MM_YY

RO BG

RO CS

RO HU

RO RS

RO UA-W

RO MD

Sum_ OF

BG RO

CS RO

HU RO

RS RO

UA-W RO

MD RO

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)In

sid

e fl

ows

(IF

)

I.06

7438

215

50

061

132

01

720

105

-506

II.06

5538

115

21

058

940

00

490

89-5

00III

.06

6531

520

41

058

570

00

490

119

-466

IV.0

613

233

145

90

400

660

028

094

-306

V.0

641

179

164

00

384

550

447

010

6-2

78V

I.06

7018

113

52

038

882

01

620

145

-243

VII.

0685

197

137

00

419

841

010

60

191

-228

VIII

.06

141

162

138

110

452

102

20

430

147

-305

IX.0

674

251

9422

044

115

10

240

019

3-2

48X

.06

8525

559

10

400

260

1184

012

1-2

79X

I.06

248

311

290

058

82

06

146

015

4-4

34X

II.06

187

415

250

062

70

04

167

017

1-4

5620

0611

3832

6214

3747

058

8471

03

2989

30

1635

-424

9

I.10

175

3789

10

302

1233

512

235

207

-95

II.10

8527

850

019

727

313

115

3821

417

III.1

080

3251

10

164

2230

792

3318

420

IV.1

073

8216

50

176

2512

2662

2615

1-2

5V

.10

6290

2323

019

811

814

2527

2320

79

VI.1

02

123

179

530

357

167

30

723

200

-157

VII.

1023

143

279

600

505

932

06

2913

0-3

75V

III.1

011

511

920

341

047

821

98

1623

77-4

01IX

.10

134

144

189

550

522

315

06

2365

-457

X.1

023

916

528

27

069

372

00

4532

149

-544

XI.1

076

114

269

380

497

364

026

3810

4-3

93X

II.10

4217

630

397

061

853

30

245

103

-515

2010

1106

1252

1968

381

047

0767

714

674

526

368

1791

-291

6

I.11

133

137

240

490

559

161

013

4373

-486

II.11

158

8721

86

046

914

40

5035

103

-366

III.1

119

110

819

414

050

710

50

4940

104

-403

IV.1

183

148

200

340

465

235

117

3480

-385

V.1

178

159

171

120

420

155

10

5529

240

-180

VI.1

110

9117

99

028

910

88

038

3018

4-1

05V

II.11

5032

192

00

274

7037

112

530

263

-11

VIII

.11

138

2712

10

028

616

4912

172

4929

812

IX.1

199

5019

00

033

944

130

153

4825

8-8

1X

.11

171

2015

90

035

075

421

215

4838

131

XI.1

118

16

283

00

470

2283

029

767

469

-1X

II.11

153

226

30

041

815

920

310

7649

375

2011

1445

867

2410

124

048

4656

834

015

1494

529

2946

-190

0

Bal

ance

Page 94: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

94 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationSerbia

Thermal nuclear net generation GWh Σ 2010 02011 0

Fossil fuels net generation GWh Σ 2010 285082011 32104

Hydraulic net generation GWh Σ 2010 124532011 9162

Other renewable net generation GWh Σ 2010 02011 0

- of which wind GWh Σ 2010 02011 0

- of which solar GWh Σ 2010 02011 0

Non-identifiable net generation GWh Σ 2010 02011 0

Total net generation, GWh Σ 2010 40961calculated to represent 100% of the national values 2011 41266

Sum of physical inside flows GWh Σ 2010 70272011 6407

Sum of physical outside flows GWh Σ 2010 67042011 5076

Total exchange balance GWh Σ 2010 -3212011 -227

Consumption of pumps GWh Σ 2010 11152011 865

National electrical consumption, GWh Σ 2010 39525calculated to represent 100% of the national values 2011 40174

Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 5161calculated to represent 100% of the national values 21.12.11 4881

Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 6491calculated to represent 100% of the national values 16.02.11 6234

Highest load on the 3rd Wednesday, MW max. 15.12.10 7034

calculated to represent 100% of the national values 16.02.11 6803

Time of highest load on the 3rd Wednesday CET 15.12.10 18:0016.02.11 19:00

Page 95: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 95

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1S

erb

ia

2 R

S d

ata

year

200

6 ar

e in

side

and

out

side

flow

s of

CS

.

MM_YY

RS 2 BA

RS 2 BG

RS 2 HR

RS 2 HU

RS ME

RS 2 MK

RS 2 RO

RS 2 AL

Sum_ OF

BA RS 2

BG RS 2

HR RS 2

HU RS 2

ME RS

MK RS 2

RO RS 2

AL RS 2

Sum_IF

Sum_IF - Sum_OF

I.06

106

035

00

203

048

707

159

338

014

10

382

5810

7837

1II.

0612

70

365

120

80

1171

210

133

20

114

038

143

971

259

III.0

680

038

42

210

02

678

730

27

790

315

9780

712

9IV

.06

870

319

1217

10

359

210

023

19

350

233

100

708

116

V.0

620

80

206

1019

80

562

710

522

58

680

179

9467

952

VI.0

626

40

220

1115

10

765

360

183

786

018

158

575

-78

VII.

0623

00

182

1317

81

3864

294

158

069

019

710

528

-114

VIII

.06

220

019

80

166

230

616

170

280

013

30

162

2977

415

8IX

.06

200

016

74

175

027

573

163

100

012

70

251

2866

996

X.0

625

20

214

085

021

572

191

152

013

90

255

3276

919

7X

I.06

252

019

20

191

019

654

184

223

021

30

311

4397

432

0X

II.06

315

020

80

190

050

763

142

313

031

60

415

2112

0744

420

0623

410

3005

5321

263

261

7789

1476

2837

3115

200

3262

613

9739

1950

I.10

295

145

32

224

50

413

7187

012

330

10

8913

580

639

3II.

1054

014

62

1218

83

040

530

124

086

166

085

9458

518

0III

.10

323

149

1610

291

70

508

3871

1161

196

051

145

573

65IV

.10

6417

174

6318

206

260

568

2037

26

112

016

145

338

-230

V.1

022

3315

315

818

191

250

600

5424

00

130

023

142

373

-227

VI.1

011

40

170

8810

203

04

589

714

80

575

017

937

451

-138

VII.

1024

70

159

7092

163

035

766

722

60

134

027

91

548

-218

VIII

.10

209

076

1893

222

841

667

823

30

1519

020

31

479

-188

IX.1

021

10

8635

106

161

062

661

1217

41

944

018

90

429

-232

X.1

019

70

133

695

139

07

577

1419

30

5174

028

286

700

123

XI.1

095

016

026

4613

50

046

232

226

032

104

026

910

476

730

5X

II.10

450

189

599

186

00

488

6925

10

319

50

303

157

978

490

2010

1319

5817

4054

451

123

0974

149

6704

362

1794

1439

214

500

1968

1047

7027

323

I.11

100

014

233

2220

20

049

928

189

022

151

024

014

677

627

7II.

1114

20

854

4213

30

941

519

222

155

790

218

2061

419

9III

.11

177

017

048

8714

00

1463

67

192

016

490

194

1247

0-1

66IV

.11

243

018

054

153

81

3867

77

261

012

180

200

149

9-1

78V

.11

207

018

950

244

90

3873

78

244

010

625

171

246

6-2

71V

I.11

193

015

251

226

730

3472

911

219

05

172

179

243

5-2

94V

II.11

167

081

1819

915

71

3966

215

191

121

110

192

143

2-2

30V

III.1

117

40

383

133

174

1227

561

3118

45

6021

112

13

426

-135

IX.1

125

30

664

129

660

2854

621

225

043

1912

190

451

4-3

2X

.11

139

064

398

631

1238

029

175

460

361

159

1547

999

XI.1

118

20

80

131

600

4242

349

243

2516

730

1328

30

810

387

XII.

1118

10

10

131

590

3440

691

276

6022

556

526

33

979

573

2011

2158

011

7626

815

9511

4415

315

6671

316

2621

9669

649

359

2410

209

6900

229

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

Page 96: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

96 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationSweden

2006 64983Thermal nuclear net generation GWh Σ 2010 55626

2011 58023

2006 13168Fossil fuels net generation GWh Σ 2010 7803

2011 5359

2006 61176Hydraulic net generation GWh Σ 2010 66215

2011 65783

2006 987Other renewable net generation GWh Σ 2010 15386

2011 17256

2006 987 - of which wind GWh Σ 2010 3479

2011 6070

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 1 140314Total net generation, GWh Σ 2010 1 145030calculated to represent 100% of the national values 2011 1 146421

2006 n.a.Sum of physical inside flows GWh Σ 2010 16988

2011 14229

2006 n.a.Sum of physical outside flows GWh Σ 2010 14728

2011 21356

2006 6052Total exchange balance GWh Σ 2010 2078

2011 -7199

2006 0Consumption of pumps GWh Σ 2010 18

2011 0

2006 146366National electrical consumption, GWh Σ 2010 147090calculated to represent 100% of the national values 2011 139222

n.a.Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 19868calculated to represent 100% of the national values 16.02.11 19392

n.a.Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 25243calculated to represent 100% of the national values 16.02.11 24031

n.a.Highest load on the 3rd Wednesday, MW max. 15.12.10 25807

calculated to represent 100% of the national values 16.02.11 24238

n.a.Time of highest load on the 3rd Wednesday CET 15.12.10 18:00

16.02.11 19:00

Page 97: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 97

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1S

wed

en

MM_YY

SE DE

SE DK_W

SE DK

SE FI

SE NO

SE PL

Sum_ OF

DE SE

DK_W SE

DK SE

FI SE

NO SE

PL SE

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)

I.06

233

72n.

a.n.

a.0

n.a.

2371

n.a.

n.a.

255

n.a.

n.a.

II.06

272

81n.

a.n.

a.0

n.a.

2567

n.a.

n.a.

199

n.a.

n.a.

III.0

613

117

n.a.

n.a.

0n.

a.14

715

8n.

a.n.

a.22

9n.

a.n.

a.IV

.06

7437

n.a.

n.a.

0n.

a.25

810

5n.

a.n.

a.24

2n.

a.n.

a.V

.06

112

83n.

a.n.

a.10

2n.

a.14

710

7n.

a.n.

a.45

n.a.

n.a.

VI.0

676

20n.

a.n.

a.96

n.a.

241

164

n.a.

n.a.

51n.

a.n.

a.V

II.06

187

90n.

a.n.

a.51

n.a.

136

87n.

a.n.

a.19

n.a.

n.a.

VIII

.06

117

n.a.

n.a.

2n.

a.33

930

1n.

a.n.

a.68

n.a.

n.a.

IX.0

620

9n.

a.n.

a.0

n.a.

216

212

n.a.

n.a.

121

n.a.

n.a.

X.0

651

68n.

a.n.

a.0

n.a.

186

173

n.a.

n.a.

66n.

a.n.

a.X

I.06

146

30n.

a.n.

a.0

n.a.

156

193

n.a.

n.a.

112

n.a.

n.a.

XII.

0617

875

n.a.

n.a.

13n.

a.70

105

n.a.

n.a.

93n.

a.n.

a.20

0614

9158

936

7671

7826

413

198

1944

1743

3767

7667

1500

1662

134

23

I.10

13

100

294

2642

432

968

032

950

874

n.a.

n.a.

II.10

02

157

400

055

937

479

055

732

389

n.a.

n.a.

III.1

01

71

721

2175

129

379

694

612

074

n.a.

n.a.

IV.1

032

126

1110

7593

1337

8529

088

169

12n.

a.n.

a.V

.10

230

535

191

1388

232

2576

3144

396

305

n.a.

n.a.

VI.1

022

069

718

912

6966

2441

6138

296

510

n.a.

n.a.

VII.

1019

964

769

844

916

021

5313

986

3639

67

n.a.

n.a.

VIII

.10

102

357

570

504

7816

1112

713

243

177

2n.

a.n.

a.IX

.10

4162

235

350

569

325

446

727

737

844

n.a.

n.a.

X.1

097

9817

429

436

699

224

461

502

871

49n.

a.n.

a.X

I.10

7911

723

451

039

979

206

359

472

368

59n.

a.n.

a.X

II.10

55

7641

45

505

232

835

735

400

79n.

a.n.

a.20

1010

0726

5626

3676

6876

114

728

2355

4978

5470

3691

494

1201

0-2

718

I.11

1831

8912

771

1416

191

739

722

2359

1734

318

II.11

1419

222

979

1512

4915

277

537

356

4213

9814

9III

.11

2949

511

578

1248

126

555

865

3256

1634

386

IV.1

122

388

2210

4287

1561

4325

761

711

436

1067

-494

V.1

123

337

6358

511

311

2113

115

427

197

5280

4-3

17V

I.11

256

774

263

227

166

1686

4233

231

739

910

54-6

32V

II.11

303

821

1080

7025

225

2611

4613

1286

213

58-1

168

VIII

.11

293

693

1044

107

210

2347

1027

1110

402

1090

-125

7IX

.11

227

783

972

337

165

2484

08

2372

02

753

-173

1X

.11

165

375

849

190

4816

2711

4691

789

093

7-6

90X

I.11

330

393

671

120

163

1677

886

334

1034

714

69-2

08X

II.11

367

478

656

627

286

2414

2112

030

047

911

931

-148

320

1120

4751

4159

3667

1815

1421

356

628

2807

4007

6509

278

1422

9-7

127

Bal

ance

Page 98: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

98 ENTSO-E Statistical Yearbook 2011

Yearly values / OperationSlovenia

2006 5281Thermal nuclear net generation GWh Σ 2010 5377

2011 5900

2006 4727Fossil fuels net generation GWh Σ 2010 4794

2011 4602

2006 3121Hydraulic net generation GWh Σ 2010 4249

2011 3362

2006 0Other renewable net generation GWh Σ 2010 0

2011 0

2006 0 - of which wind GWh Σ 2010 0

2011 0

2006 n.a. - of which solar GWh Σ 2010 0

2011 0

2006 0Non-identifiable net generation GWh Σ 2010 0

2011 0

2006 13129Total net generation, GWh Σ 2010 14420calculated to represent 100% of the national values 2011 13864

2006 7716Sum of physical inside flows GWh Σ 2010 8611

2011 7034

2006 7487Sum of physical outside flows GWh Σ 2010 10744

2011 8308

2006 202Total exchange balance GWh Σ 2010 -2172

2011 -1306

2006 0Consumption of pumps GWh Σ 2010 0

2011 0

2006 13331National electrical consumption, GWh Σ 2010 12248calculated to represent 100% of the national values 2011 12558

18.01.06 1420Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1349calculated to represent 100% of the national values 16.02.11 1358

18.01.06 2045Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 1804calculated to represent 100% of the national values 16.02.11 1837

20.12.06 2166Highest load on the 3rd Wednesday, MW max. 15.12.10 1919

calculated to represent 100% of the national values 19.01.11 1907

20.12.06 19:00Time of highest load on the 3rd Wednesday CET 15.12.10 19:00

19.01.11 15:00

Page 99: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 99

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1S

love

nia

MM_YY

SI AT

SI HR

SI IT

Sum_ OF

AT SI

HR SI

IT SI

Sum_IF

Sum_IF - Sum_OF

Ou

tsid

e fl

ow

s (O

F)

Insi

de

flo

ws

(IF

)B

alan

ce

I.0

62

22

14

418

654

10

762

17

731

19II

.06

15

81

04

776

451

47

071

722

77II

I.0

61

28

19

566

713

25

724

27

5138

IV.0

61

21

77

017

3013

97

990

938

208

V.0

66

103

591

700

86

602

06

88-1

2V

I.0

62

518

15

207

269

84

840

582

-144

VII

.06

73

139

444

656

108

493

16

02-5

4V

III.

06

56

209

289

554

96

367

14

64-9

0IX

.06

85

132

204

421

65

373

44

4221

X.0

61

12

94

415

621

90

512

16

03-1

8X

I.0

64

67

93

925

175

25

031

556

39X

II.0

61

39

39

372

550

50

545

05

9545

2006

1062

1036

5389

7487

833

6871

1277

1622

9

I.1

03

519

07

279

5212

76

142

17

62-1

90II

.10

36

145

775

956

146

708

58

59-9

7II

I.1

03

320

08

6210

95

104

751

78

62-2

33IV

.10

55

179

726

960

80

656

28

764

-196

V.1

03

026

06

979

8711

15

854

700

-287

VI.

10

10

306

580

896

204

445

10

659

-237

VII

.10

035

73

947

5133

73

336

676

-75

VII

I.1

06

415

724

9317

01

041

22

86-2

07IX

.10

132

25

268

4923

33

406

579

-270

X.1

03

48

610

661

364

492

14

870

209

XI.

10

72

136

880

108

813

06

935

828

-260

XII

.10

30

38

96

6410

56

57

592

766

-290

2010

584

2647

7513

1074

420

1164

8012

086

11-2

133

I.1

11

69

137

523

829

28

611

06

39-1

90II

.11

27

178

430

635

111

464

25

77-5

8II

I.1

18

212

94

836

9411

15

683

682

-12

IV.1

13

324

24

877

6212

74

444

575

-187

V.1

16

329

414

749

274

366

36

43-1

06V

I.1

11

329

43

906

9722

03

524

576

-121

VII

.11

332

94

017

3334

43

132

659

-74

VII

I.1

11

132

92

145

5418

52

201

74

22-1

32IX

.11

18

270

315

603

163

319

74

89-1

14X

.11

18

286

444

748

242

382

56

29-1

19X

I.1

17

327

351

685

327

259

55

91-9

4X

II.1

11

527

03

346

1924

92

921

15

52-6

720

1140

231

2047

8683

0823

8145

9063

7034

-127

4

Page 100: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

100 ENTSO-E Statistical Yearbook 2011

1Including deliveries from industry

Yearly values / OperationSlovak Republic

2006 16631Thermal nuclear net generation GWh Σ 2010 13576

2011 14379

2006 5409Fossil fuels net generation GWh Σ 2010 5620

2011 6331

2006 4401Hydraulic net generation GWh Σ 2010 5523

2011 4007

2006 10Other renewable net generation GWh Σ 2010 474

2011 863

2006 3 - of which wind GWh Σ 2010 7

2011 0

2006 n.a. - of which solar GWh Σ 2010 9

2011 307

2006 2591Non-identifiable net generation GWh Σ 2010 931

2011 968

2006 1 29042Total net generation, GWh Σ 2010 1 26124calculated to represent 100% of the national values 2011 1 26548

2006 9325Sum of physical inside flows GWh Σ 2010 7342

2011 11228

2006 10925Sum of physical outside flows GWh Σ 2010 6295

2011 10501

2006 -1602Total exchange balance GWh Σ 2010 1042

2011 727

2006 232Consumption of pumps GWh Σ 2010 530

2011 495

2006 27208National electrical consumption, GWh Σ 2010 26636calculated to represent 100% of the national values 2011 26780

18.01.06 3573Consumption load 3:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 3390calculated to represent 100% of the national values 16.02.11 3144

18.01.06 4194Consumption load 11:00 a.m. on the 3rd Wednesday, MW max. 15.12.10 4126calculated to represent 100% of the national values 16.02.11 4115

20.12.06 4316Highest load on the 3rd Wednesday, MW max. 15.12.10 4326

calculated to represent 100% of the national values 16.02.11 4126

20.12.06 17:00Time of highest load on the 3rd Wednesday CET 15.12.10 17:00

16.02.11 10:00

Page 101: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

1

The

se p

hysi

cal e

nerg

y flo

ws

wer

e m

easu

red

on th

e tie

line

s (>

110

kV).

The

se v

alue

s m

ay d

iffer

from

the

offic

ial s

tatis

tics

and

the

tota

l exc

hang

e ba

lanc

e in

the

tabl

e "M

onth

ly v

alue

s / O

pera

tion"

.

ENTSO-E Statistical Yearbook 2011 101

GW

hP

hys

ical

exc

han

ges

in

in

terc

on

nec

ted

op

erat

ion

1S

lova

k R

epu

blic

MM_YY

SK CZ

SK HU

SK PL

SK UA-W

Sum_ OF

CZ SK

HU SK

PL SK

UA-W SK

Sum_IF

Sum_IF - Sum_OF

Out

sid

e fl

ow

s (O

F)

Insi

de fl

ows

(IF

)B

alan

ce

I.06

107

813

022

511

4549

50

361

486

0-2

85II.

0669

739

018

299

044

50

385

583

5-1

55III

.06

9769

90

127

923

371

030

75

683

-240

IV.0

663

615

064

742

287

028

16

574

-168

V.0

680

604

088

772

316

025

08

574

-198

VI.0

649

650

063

762

317

019

96

522

-240

VII.

0639

586

455

684

408

015

927

594

-90

VIII

.06

3469

60

5878

859

70

1912

628

-160

IX.0

66

554

012

768

745

70

310

577

285

X.0

629

759

021

210

0062

70

402

510

3434

XI.0

614

824

023

610

7474

30

315

510

63-1

1X

II.06

2510

530

280

1358

794

038

66

1186

-172

2006

612

8592

417

1710

925

5857

033

7494

9325

-160

0

I.10

2435

34

6444

540

90

147

2257

813

3II.

106

373

079

458

475

018

710

672

214

III.1

016

447

111

958

342

10

220

864

966

IV.1

019

517

213

166

945

70

168

763

2-3

7V

.10

2833

910

5242

934

60

9912

457

28V

I.10

3439

320

5149

830

60

639

378

-120

VII.

101

602

015

876

186

10

179

510

4528

4V

III.1

022

539

664

631

431

087

1152

9-1

02IX

.10

644

78

5551

659

10

115

607

91X

.10

755

80

9566

067

70

176

1386

620

6X

I.10

5428

01

3937

438

83

126

4656

318

9X

II.10

149

8631

527

113

653

4513

236

695

2010

366

4934

8391

262

9554

9856

1498

290

7342

1047

I.11

7336

513

2447

519

74

7675

352

-123

II.11

1956

90

8967

744

20

202

1265

6-2

1III

.11

4951

61

115

681

466

025

411

731

50IV

.11

3257

33

5866

643

40

170

1662

0-4

6V

.11

2657

63

7367

845

10

166

1963

6-4

2V

I.11

2143

56

7153

343

01

125

2257

845

VII.

116

867

018

610

5987

90

149

310

31-2

8V

III.1

10

799

024

410

4398

40

188

311

7513

2IX

.11

165

20

269

922

689

032

42

1015

93X

.11

185

30

274

1128

928

039

54

1327

199

XI.1

10

869

034

112

1099

00

486

414

8027

0X

II.11

010

460

383

1429

1101

051

97

1627

198

2011

228

8120

2621

2710

501

7991

530

5417

811

228

727

Page 102: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 103: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

European Network ofTransmission System Operators

for Electricity

1 ENTSO-E Net generation, exchanges

and consumption 2011

2 Yearly values / operation and

physical exchanges

3 System information

4 Glossary of statistical terms

Page 104: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 105: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 105

IISystem information

Statistical database as of 31 August 2012

Page

Inventory of transmission network installations as of 31 December 2011 ........................................................................106

Number of circuits < 220kV, 220 kV and over 220 kV on tie lines ......................................................................................107

Simplified diagram of tie lines of the ENTSO-E synchronous area as of 31 December 2011 .........................................109

Characteristics of the ENTSO-E tie lines as of 31 December 2011 .................................................................................. 110

Unavailability of international tie lines - yearly overview 2011 ............................................................................................121

Page 106: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

106 ENTSO-E Statistical Yearbook 2011

Inventory of transmission network installations as of 31 December 2011

1 Values as of 31 December 20102 ENTSO-E calculated sum of the member TSOs´ countries3 ENTSO-E calculated sum of DC cable length is equal to 5368 km and includes NorNed Cable (580 km), BritNed (520 km),

FR Suvereto - IT Lucciana (430 km), Kontek (170 km), Skagerrak 1 (438 km), Skagerrak 2 (438 km), Skagerrak 3 (219 km),Konti-Skan 1 (176 km), Konti-Skan 2 (149 km), IT Galatina - GR Arachtos (316 km), IFA (140 km), Moyle Interconnector (127 km),East-West Interconnector (260 km), Baltic Cable (269 km), SwePol (254 km), Fenno-Skan 1 (233 km), Fenno-Skan 2 (300 km),Estlink (105 km), ES Balearic System and ES Mainland (488 km).

AC DC AC DC AC DC AC DC AC DC

55838256763TA

056805251AB

053315154EB

0580723205182GB

88871328194HC

CY 1 1227 120

0805309091 ZC

07703029327441ED

1738051132207KD

EE 3537 114 184 0 1540 0

552269154552671SE

0133401062 IF

346312910164562RF

922979112256216BG

5443476248411 RG

0842100121 RH

08620708203341UH

09349212681EI

0158SI

6647230113445201TI

02761541105 TL

81952UL

LV 3946 63 3940 67 1250 0

ME 1 00820004

07050301 KM

NI 1282 85 828 4

0319029076LN

24455380544ON

04110253511297 LP

06322248743 TP

09510768405574OR

0317104822SR

88070100044 ES

08050823 IS

015510857KS

15003 427 365 141214 3356 2142 4462 0 0 149105 1742 1207 626 0 1654

of which cable 330 kV

of which cable 380/400 kV

ENTSO-E 2,3

Country < 220 kV

of which cable 220 - 285 kV

of which cable< 220 kV

Lenghts of circuits in km

380/400 kV < 400 kV330 kV220 - 285

kV

of which cable< 400 kV

Page 107: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 107

Number of circuits < 220 kV, 220 kV and over 220 kV on tie lines

Number of < 220 kV and > 220 kV circuits on tie lines of all ENTSO-E member TSOs' countries and in synchronous operationwith ENTSO-E countries:

1 Between FI - RU is no synchronous operation. Two 110 kV andone 400 kV interconnections operate so that one or severalRussian power units are connected to the Finnish system butisolated from the Russian system.Two 400 kV interconnections connect the Finnish and Russiansystems asynchronously through a back-to-back HVDC-link.

UA

AT BA BE BG CH CZ DE DK EE ES FI FR GB GR HR HU IE IT LT LU LV ME MK NI NL NO PL PT RO RS SE SI SK W AL BY MA MD RU TR UA

1 - 20 - -AT 2 2 11 2 1 1

2 2 3 2 - 211 3 3

BA 7 2 12 1 1

- 2 -BE 3 2 -

3 - 4- 2 - 2 -

BG - - - - -1 1 4 1 2

2 - 1CH 5 5 5

7 5 5- 7 -

CZ - 2 24 2 3

1 - - - 1 -DE 2 2 8 - 2 -

3 4 - 5 2 1- -

DK 2 21 2

1 - -EE - - -

- 4 32 1 -

ES 2 3 -2 5 2

- 1 2FI1 1 1 -

- 4 3- 1

FR 2 3- 3

1 - -GB - 2 -

- - 2- - 1 -

GR - - - -1 2 1 1

2 2 3HR - - 2

4 1 3- 1 - -

2---UH2 1 2 2

-IE 2

330, 380, 400, 450 and 750 kV --

IT 12

As of 31.12.2011 3 7 3LT - - -

4 5 3-

LV -1

1 -ME 2 1

1 1-

MK 21

- 1 1NO - 1 -

1 4 -- - 2 -

PL - - 1 11 2 - 1

3 - -RO - - -

1 1 1-

RS 1-

-SK -

1

< 220 kV220 kV (including 285 kV)

Page 108: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 109: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 109

Simplified diagram of the ENTSO-E tie lines of the synchronous area of ENTSO-E as of 31 December 2011

LEGEND

750 kV

380/400 kV

300/330 kV

220 kV

110/150 kV

Substation

Frontier point

Direct current line

Number of lines

PTES

FR

BE

LU

IE

NI

GB

NL

DK

DE

CH

IT

AT

PL

CZ

SK

SI

HU

HR

BA

ME

MK

RS

GR

BG

RO

UA-W

LTLV

EE

NO

FI

SE

MA

TR

MD

UA

BY

RU

RU

AL

REN

REE

RTE

CREOS

Elia

National Grid

EirGrid

SONI LtdEnerginet.dk IPC

TenneT

ONE

Terna S.p.A.

ELES

EPS

Statnett SF

Svenska Kraftnät

Fingrid Oyj

PSE Operator

Elering AS

Litgrid AB

Augstspriegumatïkls

SEPS, a.s.

MAVIR ZRt.

VUEN

Austrian Power Grid AG

Amprion

TransnetBW

TenneT TSO GmbH

50Hertz Transmission

HEP-OPS

ISO BiH

EMS

EPCG

MEPSO

ESO

Transelectrica

NPC Ukrenergo

IPTO SA

KESH

swissgrid

380 kV

±220 kV

±380 kV

±450 kV

400 kV

500 kV

±400 Kv

400 kV

±450 kV

±250 kV350 kV

±285 kV

±250 kV

±270 kV

275 kV

2

2

2

2

2

2 2 2

2

2

2

5

2

2

2

2

22

2

4

2

4 2 122

2

2

2

2

2

2

22 2

(Temporary out of operation)

(radial operation)

(Schärding-St. Peter operated by ÖBK)

(Bürs located inGerman control block)

(radial operation)

(Temporary out of operation)

(radial operation)

3

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

3

7

2

(Temporary out of operation)

2

601

233

232

234

151

152

94

92

95

93 91

153

235

123

125121

122

132 181 182

352251

364

213

252 371

332

331

383

381

205

382 384

391

281

280

282

292 241

301

293

342

273

761

760

272

263

264

262

750

753

741

740

720

752

731

730

261

271

277 278 275

341

242

291

362

363

361

201351

124

141

142112

111

116

117

115 172

321

322

501502

401162

171

430 410 404

700

443444460472

470

471

473

503

474

450

704

701

703 705

702

711710212

211

440

721

722

424

420

82

81 83

72

51

52

41

2513

15

11

27

163 164

166

772

776771 773

774

775

777 801

780

800804

802

805

803

790

810

813

812

820

833831

830832

851

852

856

845

855

854

885

881 882880

850

853

842

840

862

861

865 871to

860

864863

841

811

165

168

167

169

170

161

26

28

71

192

221

222

225

222

191

104

102 103

105

883 to

751

MELOUSSA 1

ALTO LINDOSO

LAGOAÇA

POCINHO

FALAGUEIRA

ALQUEVA

CARTELLE

ALDEADAVILA

SAUCELLE

CEDILLO

BROVALES

ARKALE

BIESCAS

VICH

HERNANI

PRAGNERES

BAIXAS

TRINITE VICTOR

LUCCIANA

ALBERTVILLE

VILLARODIN

CAMPOROSSO

SUVERETO

RONDISSONE

AVISE

CAGNO

MESE

LIENZ

PONTE

SIERENTZ

VOGELGRÜN

VIANDEN

FLEBOURAUBANGE

MAASBRACHT

HENGELO

MEEDEN

BORSSELE

EEMSHAVEN

MASSVLAKTE

ROOST

HEISDORF

VAN EYCKZANDVLIET

MONCEAU

AVELGEM ACHENE

MOULAINE

MONT ST. MARTIN

LONNY

CHOOZAVELIN

MASTAING

MANDARINS

AUCHENCROSH

TANDRAGEE

LOUTH

SELLINDGE

GRAIN

BALLYCRONANMORE

NIEDERSTEDEM

ROMMERSKIRCHEN

GRONAU

SIERSDORF

DIELE

GEERTRUIDENBERG

BAULERBELVAL

TRIER

QUINT

MÜHLBACH

ST AVOLD

VIGY

ENSDORF

AUDORF FLENSBURG

KASSØ

TJELE

FEDA

ENSTED

EICHSTETTEN KÜHMOOS

TROSSINGEN

GURTWEIL TIENGEN

BASSECOURTMAMBELIN

CHAMOSONBOIS TOLLOT

VERBOIS

ASPHARD

LAUFENBURG

BEZNAU

OBERMOOWEILER

WINKELN

MEININGEN

MEMMINGEN

WESTTIROL

DELLMENSINGEN

LEUPOLZ

OBERBRUNN

SILZ

PLEINTING

ST. PETER

P EŠTICE

HRADEC ZÁPAD

HRADEC VÝCHOD

S UPSK

NOŠOVICE

LÍSKOVEC

KROSNO-ISKRZYNIA

DOBRZE

WIELOPOLE

SOVETSKBIT NAI

KRUONIO HAE

VELIKORECKAYA

ŠIAULIAI/TELŠIAI MINSKAJA TEC-5

STÄRNÖ

KOPANINA

BUJAKÓW

ALBRECHTICE

ETZENRICHT

ROEHRSDORF

HERRENWYK

KRUSEBERG

RAUMO

KINGISEPP

KEMINMAA

PETÄJÄSKOSKI

OSSAUSKOSKI

VARANGERBOTN

KYMI

ESPOO

HARKU

SINDI

YLLIKKÄLÄ VIBORG

EESTI BALTI

TARTU

LENINGRADSKAJA

PSKOVTARTU

TEC-2TEC-1

FORSMARK

SVARTBYN

LETSI

FINBÖLE

KALIX

IVALO

LINDOME

RITSEMOFOTEN

HALDENNEA

AJAURE

HASLE JÄRPSTRÖMMENBORGVIK

NEDRE RØSSAGÅ

SKOGSSTÄTER

BJAEVERSKOV

GØLØRSEGÅRD

HOVEGÅRD

TEGLSTRUPGÅRD

MÖRAP 1 & 2

SÖDERÅSEN

BORRBYBORNHOLM

VESTER HASSING

KRISTIANSAND

BENTWISCH

KRAJNIK

MIKU OWA

VIERRADEN

HAGENWERDER

PIRACH

ALTHEIM

SIMBACH

SCHÄRDING

OBERSILACH KAINACHTAL

BÜRS

Y-MEININGEN

HERBERTIGEN

PRADELLA

GENISSIAT

ST. TRIPHON

RIDDES SERRA

CORNIER

VALLORCINEPRESSY

VENAUS

VALPELLINE

PALLANZENO

MENDRISIO

LAVORGOROBBIA

MUSIGNANO

SOAZZA

BULCIAGO

GORLAGO

SOVERZENE

PADRICIANO

REDIPUGLIA

GALATINA

DIVA A

PODLOG MARIBOR

DÜRNROHR BISAMBERG

WIEN S.O.

SARASDORF

NEUSIEDL

KISVÁRDA

TISZALÖK

ALBERTIRSA

ARAD

NADAB ROSIORI

ISACCEA VULCANESTI

MUKACHEVO

GYÖR GÖD

SLAV TICE

SOKOLNICE

STUPAVA

VANY

GAB IKOVO V.KAPUŠANY

SAJÓSZÖGED

LEVICE

P. BYSTRICA

LEMEŠANY

RZESZÓW

ZAMO

KHMELNYTSKA

BIA YSTOK

PANEV

KLAIP DASMORGON

GRODNOVILNIUS

ALYTUS

POLOCK

MOLODECCHNO

AIZKRAUKLE

TSIRGULINA

GROBINA

VALMIERA REZEKNE

JELGAVA(VISKALI)

LIKSNA

IAE

ROS

DOBROTVIR

VARIN

SENICA

KRŠKO TUMBRI

CIRKOVCE

PEHLIN

MELINA TUZLA

ME URI

AVINECERNESTINOVO SR. MITROVICA

SÁNDORFALVASZOMBATHELYPÉCS

BÉKÉSCSABA

SUBOTICA 3

GRADA AC

UGLJEVIK

VIŠEGRAD

SARAJEVO

PODGORICA

PERUC CA RIBAREVINA

PLJEVLJA

POZEGA

PEC 3

UROSEVAC

KOSOVO A

SKOPLJE 5

STIP

NIŠ

SKOPLJE 1

DUBROVOBITOLA

KOZLODUI

ERDAP

TÂNT RENI

DOBRUDJA

ELBASSAN

ARACHTHOS

NEA SANTA

THESSALONIKI

BLAGOEVGRAD

CERVENA MOGILA

MARITZA EAST 3

PORTILE DE FIER

ZAHIDNOUKRAINSKA

PIV. UKRAINSKA

HAMITABAT

BABAESKI

PRIZREN

SOFIJA VARNA

FIJERZA

KARDIA MELTI

B. BASTA

VAU DEJESTIRANA

PIVA

VARDIŠTE

HÉVÍZ

MRACLIN

ZAKU AC

KONJSKO

AKOVO

DUBROVNIK

PRIJEDOR

MOSTAR

TREBINJE

SAN FIORANO

ALL’ACQUA

GORDUNO

ARGIA

PUERTO DE LA CRUZ

RIDDES

Page 110: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

110 ENTSO-E Statistical Yearbook 2011

Characteristics of the ENTSO-E tie lines as of 31 December 2011

Observations

[ 1 ] Limited by phase shifting transformer in Meeden [ 2 ] Limited by phase shifting transformer in Meeden[ 3 ] DC submarine cable[ 4 ] Unit is MW instead of MVA[ 5 ] Transducer[ 6 ] Line property TransNetBW in Germany partielly on the same tower as line Asphard-Kühmoos or Sierentz-Laufenburg; Line owned and operated by EnBW in Germany[ 7 ] DC link with three connections[ 8 ] Transforming station of Lucciana in Corsica[ 9 ] DC link with three connections[ 10 ] Transforming station of Lucciana in Corsica[ 11 ] Partially on the same tower as the Laufenbourg-Engstlatt line (No. 105.1): Alb- Nord[ 12 ] On the same tower as line No. 81 Laufenburg-Sierentz 380 kVLeitung: Hotzenwald[ 13 ] From Kühmoos to Laufenbourg on the same tower; Leitung Eggberg[ 14 ] On the same tower as line Sierentz-Laufenburg[ 15 ] On CH side: The Trafo 20 in Laufenburg 200 MVA[ 16 ] Limited by switching devices in Austria[ 17 ] Disconnected till approx. 2010; afterwards line will be dismantled[ 18 ] Cable at Braunau[ 19 ] Cable at Braunau

Page 111: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 111

*The conventional transmission capacity of tie lines is based upon parameters standardised within former UCTE for the calculation of the thermal load capability of each line. For arial lines these are : ambient temperature of + 35°C, wind velocity of 0,56 m/s at a right angle to the line as well as the voltage value stated in column 10 or11. The conditions relevant to system operation in various countries at various time of the year can strongly differ from those above. Because the real allowable load capability of the line depends on many other factors, such as load flow distribution, upholding of voltage, real ambient conditions, limits of stability, n-1 security, etc., theconventional transmission capacity has no relevance from the point of view of system operation or economics but allows just a comparison of order of magnitude of the various lines. Adding together the conventional transmission capacity of several tie lines does not allow to infer on the real total transmission capability and leads toirrelevant results from the point of view of system operation.

(Frontier point.Line.Circuit) Country Name Operated by Country Name Operated by

Nr. kV kV M V A M V A M V A kV M V A kV

1 2 3 4 5 6 7 8 9 10 11 12 13 14

11.1.1 DE Diele TenneT DE NL Meeden TenneT NL 380 1382 1000 [1]11.1.2 DE Diele TenneT DE NL Meeden TenneT NL 380 1382 1000 [2]13.1.1 DE Siersdorf Amprion NL Maasbracht TenneT NL 380 164513.1.2 DE Rommerskirchen Amprion NL Maasbracht TenneT NL 380 169815.1.1 DE Gronau Amprion NL Hengelo TenneT NL 380 164515.1.2 DE Gronau Amprion NL Hengelo TenneT NL 380 164525.1.1 BE Van Eyck Elia NL Maasbracht TenneT NL 380 120725.1.2 BE Van Eyck Elia NL Maasbracht TenneT NL 380 127026.1.1 BE Zandvliet Elia NL Geertruidenberg TenneT NL 380 147626 .2 .1 BE Zandvliet Elia NL Borssele TenneT NL 380 1476 45027.1.1 NO Feda Statnett NL Eemshaven TenneT NL 450 700 [3,4]28.1.1 GB Isle of Grain National Grid NL Maasvlakte TenneT NL 450 50028 .2 .1 GB Isle of Grain National Grid NL Maasvlakte TenneT NL 450 50041.1.1 BE Aubange Elia LU Belval SOTEL 220 35841.1.2 BE Aubange Elia LU Belval SOTEL 220 35841.2.1 BE Aubange Elia LU Belval SOTEL 150 157 10041.3.1 BE Aubange Elia LU Belval SOTEL 150 157 10051.1.1 BE Monceau Elia FR Chooz RTE 220 33851.2.1 BE Avelgem Elia FR Mastaing RTE 380 116851.2.2 BE Avelgem Elia FR Avelin RTE 380 130351.3.1 BE Achène Elia FR Lonny RTE 380 116852.1.1 BE Aubange Elia FR Moulaine RTE 220 38152.2.1 BE Aubange Elia FR Mont St Martin RTE 220 38171.1.1 DE Ensdorf Amprion FR Vigy RTE 380 179071.1.2 DE Ensdorf Amprion FR Vigy RTE 380 179071.2.1 DE Ensdorf Amprion FR St-Avold RTE 220 26172.1.1 DE Eichstetten TransnetBW FR Vogelgrün RTE 380 220 338 [5] 22072.1.2 DE Eichstetten TransnetBW FR Muhlbach RTE 380 168481.1.1 CH Bassecourt swissgrid FR Sierentz RTE 380 117281.2.1 CH Laufenburg swissgrid FR Sierentz RTE 380 94681.3.1 CH Bassecourt swissgrid FR Mambelin RTE 380 84682.1.1 CH Verbois swissgrid FR Bois-Tollot RTE 380 155282.1.2 CH Chamoson swissgrid FR Bois-Tollot RTE 380 155282 .2 .1 CH Verbois swissgrid FR Génissiat RTE 220 23782 .2 .2 CH Verbois swissgrid FR Génissiat RTE 220 23782 .4 .1 CH Vallorcine swissgrid FR Pressy RTE 220 35582.5.1 CH Riddes swissgrid FR Cornier RTE 220 21682 .6 .1 CH St.-Triphon swissgrid FR Cornier RTE 220 222

83.1.1 [6] CH/DE Asphard swissgrid/EnBW Tr.netze Strom FR Sierentz RTE 380 116891.1.1 FR Albertville RTE IT Rondissone Terna 380 124491.1.2 FR Albertville RTE IT Rondissone Terna 380 124492.1.1 FR Trinite Victor RTE IT Camporosso Terna 220 31993.1.1 FR Villarodin RTE IT Venaus Terna 380 1237

94.1.1 [7] FR Lucciana EDF IT Suvereto Terna 220 [8] 300 5094.1 .2 [9 ] FR Lucciana EDF IT Suvereto Terna 220 [10] 300 50

95.1.1 FR Bonifacio EDF IT Santa Teresa Terna 150 53102.1.1 [11] CH Laufenburg swissgrid DE Gurtweil TransnetBW 220 442 220

102.1.2 CH Laufenburg swissgrid DE Gurtweil TransnetBW 220 457 220102.2.1 [12] CH Laufenburg swissgrid DE Kühmoos TransnetBW 220 410102.3.1 [13] CH Laufenburg swissgrid DE Kühmoos TransnetBW 380 220 430

102.3.2 CH Laufenburg swissgrid DE Kühmoos TransnetBW 380 1527102.4.1 CH Laufenburg swissgrid DE Kühmoos TransnetBW 380 1527102.4.2 CH Laufenburg swissgrid DE Kühmoos Amprion 380 1607102.5.1 CH Laufenburg swissgrid DE Tiengen Amprion 380 1122103.1.1 CH Beznau swissgrid DE Tiengen Amprion 380 1158103.1.2 CH Beznau swissgrid DE Tiengen Amprion 380 220 335

104.1.1 [14] CH Asphard swissgrid DE Kühmoos TransnetBW 380 1263105.1.1 CH Laufenburg swissgrid DE Trossingen TransnetBW 380 1607

107.1.1 [15] CH Laufenburg 220kV swissgrid DE Laufenburg 110 kV ED 110 200111.1.1 AT Bürs VIW DE Obermooweiler TransnetBW 380 1369111.1.2 AT Bürs VIW DE Obermooweiler TransnetBW 380 1369111.2.1 AT Bürs VIW DE Herbertingen Amprion 220 389111.3.1 AT Bürs VIW DE Dellmensingen Amprion 220 492 457 [16]111.4.1 AT Rieden Vorarlberg Netz DE Lindenberg Vorarlberg Netz 110 84111.4.2 AT Hörbranz Vorarlberg Netz DE Lindau Vorarlberg Netz 110 84111.4.3 AT Werben Vorarlberg Netz DE Lindau Vorarlberg Netz 110 162111.5.1 AT Vorderwald Vorarlberg Netz DE Weiler Vorarlberg Netz 110 127112.1.1 AT Feldkirch Vorarlberg Netz CH Eschen swissgrid 110 130115.1.1 AT Braunau Grenzkraftwerke AG DE Neuötting E.ON Netz GmbH 110 90 [17] 82 [18]115.2.1 AT Braunau Grenzkraftwerke AG DE Stammham E.ON Netz GmbH 110 102 82 [19]115.4.1 AT Antiesenhofen APG DE Egglfing E.ON Netz GmbH 110 102115.5.1 AT St. Peter APG DE Altheim TenneT DE 220 301

PresentVol tage

15

Voltage of the circuit

Forecast PresentTransmission

capacityForecastat Vol tage

Conventional trans-mission capacity of theconnection (thermal)*

Limited by the transformers or by the substationsof circuits of lines

Connection between:

From substation to substationCircuit ID

Page 112: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

112 ENTSO-E Statistical Yearbook 2011

Characteristics of the ENTSO-E tie lines as of 31 December 2011

Observations

[ 20 ] Transducer at Ering

[ 21 ] Transducer at Ering

[ 22 ] Isolator in St. Peter

[ 23 ] Isolator in St. Peter

[ 24 ] Only temporary line; f rom December 2005 t ill summer 2006; af terwards disconnected t ill approx.2010

[ 25 ] No internat ional interconnector

[ 26 ] CFT blocker at St. Peter

[ 27 ] No internat ional interconnector

[ 28 ] CFT blocker at St. Peter

[ 29 ] Switching device at Oberbrunn

[ 30 ] Switching device at Oberbrunn

[ 31 ] Possible to lay a second circuit=> Not yet managed by swissgrid, so no technical data available.

[ 32 ] Limited by t ransformer in Enstedt

[ 33 ] Limited by t ransformer in Kassø

[ 34 ] Transducer at Kassø

[ 35 ] Transducer at Kassø

[ 36 ] DC submarine and underground cable

[ 37 ] DC submarine and underground cable

[ 38 ] DC submarine and underground cable

[ 39 ] Under water cable

[ 40 ] Under water cable

[ 41 ] Under water cable

[ 42 ] Generator line in radial operation - interconnected operat ion impossible; Installed at Vianden

[ 43 ] Generator line in radial operation - interconnected operat ion impossible; Installed at Vianden

[ 44 ] Generator line in radial operation - interconnected operat ion impossible; Installed at Vianden

Page 113: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 113

*The conventional transmission capacity of tie lines is based upon parameters standardised within former UCTE for the calculation of the thermal load capability of each line. For arial lines these are : ambient temperature of + 35°C, wind velocity of 0,56 m/s at a right angle to the line as well as the voltage value stated in column 10 or11. The conditions relevant to system operation in various countries at various time of the year can strongly differ from those above. Because the real allowable load capability of the line depends on many other factors, such as load flow distribution, upholding of voltage, real ambient conditions, limits of stability, n-1 security, etc., theconventional transmission capacity has no relevance from the point of view of system operation or economics but allows just a comparison of order of magnitude of the various lines. Adding together the conventional transmission capacity of several tie lines does not allow to infer on the real total transmission capability and leads toirrelevant results from the point of view of system operation.

(Frontier point.Line.Circuit) Country Name Operated by Country Name Operated by

Nr. kV kV M V A M V A M V A kV M V A kV

1 2 3 4 5 6 7 8 9 10 11 12 13 14

115.6.1 AT St. Peter APG DE Simbach TenneT DE 220 301115.7.1 AT St. Peter APG DE Ering E.ON Netz GmbH 110 152 137 114 [20]115.7.2 AT St. Peter APG DE Ering E.ON Netz GmbH 110 152 137 114 [21]115.8.1 AT St. Peter APG DE Egglfing E.ON Netz GmbH 110 105115.9.1 AT St. Peter APG DE Pirach TenneT DE 220 518 457 [22]115.10.1 AT St. Peter APG DE Pleinting TenneT DE 220 449 457 [23]115.11.1 AT Ranna EAGOÖ-Netz DE Passau/Hauzenberg E.ON Netz GmbH 110 90 [24]115.12.1 AT Oberaudorf ÖBK DE Rosenheim E.ON Netz GmbH 110 93115.13.1 AT Oberaudorf ÖBK DE Kiefersfelden E.ON Netz GmbH 110 102115.14.1 AT Antiesenhofen EAGOÖ-Netz DE Weidach APG 1 110 130115.14.2 AT Antiesenhofen EAGOÖ-Netz DE Weidach APG 1 110 130115.15.1 AT Aigerding APG / EAGOÖ-Netz DE Passau Grenzkraftwerke AG 110 102

115.16.1 [25] AT St. Peter APG DE Schärding ÖBK 220 301 229 [26]115.16.2 [27] AT St. Peter APG DE Schärding ÖBK 220 301 229 [28]

115.17.1 AT Kufstein TIWAG-Netz DE Oberaudorf Grenzkraftwerke AG 110 90115.17.2 AT Ebbs TIWAG-Netz DE Oberaudorf Grenzkraftwerke AG 110 127116.1.1 AT Westtirol APG DE Leupolz Amprion 380 1316116.2.1 AT Westtirol APG DE Memmingen Amprion 220 762117.1.1 AT Silz APG DE Oberbrunn TenneT DE 220 793 762 [29]117.1.2 AT Silz APG DE Oberbrunn TenneT DE 220 793 762 [30]117.3.1 AT Reutte TIWAG-Netz DE Füssen EW Reutte 110 127117.3.2 AT Reutte TIWAG-Netz DE Füssen EW Reutte 110 127121.1.1 CH All'Acqua swissgrid IT Ponte Terna 220 278121.2.1 CH Gorduno swissgrid IT Mese Terna 220 278121.3.1 CH Soazza swissgrid IT Bulciago Terna 380 1224121.4.1 CH Lavorgo swissgrid IT Musignano Terna 380 1204

122.1.1 [31] CH Campocologno RE IT Poschiavino Terna 150 103 42123.1.1 CH Riddes swissgrid IT Avise Terna 220 309123.2 .1 CH Riddes swissgrid IT Valpelline Terna 220 309123.3 .1 CH Serra swissgrid IT Pallanzeno Terna 220 278124.1.1 CH Robbia swissgrid IT Gorlago Terna 380 1330124.1.2 CH Robbia swissgrid IT San Fiorano Terna 380 1330125.1.1 CH M endrisio swissgrid IT Cagno Terna 380 450 200132.1.1 AT Lienz APG IT Soverzene Terna 220 257141.1.1 AT M einingen APG on behalf of VUEN CH Y-Meiningen swissgrid 220 494141.2.1 AT M einingen APG on behalf of VUEN CH Winkeln swissgrid 220 765142.1.1 AT Westtirol APG CH Pradella swissgrid 380 1330142.2 .1 AT Westtirol APG CH Pradella swissgrid 380 1330151.1.1 ES Hernani REE FR Argia RTE 380 1137151.2.1 ES Irún REE FR Errondenia RTE 132 59151.3.1 ES Arkale REE FR Argia RTE 220 339151.4.1 ES Biescas REE FR Pragnères RTE 220 183152.1.1 ES Benós REE FR Lac d'Oo RTE 110 76153.1.1 ES Vich REE FR Baixas RTE 380 1348161.1.1 DE Flensburg TenneT DE DK Ensted Energinet.dk IPC 220 332 305 [32]161.2.1 DE Flensburg TenneT DE DK Kassø Energinet.dk IPC 220 332 305 [33]161.3.1 DE Audorf TenneT DE DK Kassø Energinet.dk IPC 380 1078 658 [34]161.3.2 DE Audorf TenneT DE DK Kassø Energinet.dk IPC 380 1078 658 [35]161.4.1 DE Flensburg UW Nord Stadtwerke Flensburg DK Ensted Energinet.dk IPC 150 150

162.1.1 [36] DE Bentwisch 50Hertz DK Bjæverskov Energinet.dk IPC 400 600163.1.1 [37] NO Kristiansand Statnett SF DK Tjele Energinet.dk IPC 250 250

163.1.2 [38] NO Kristiansand Statnett SF DK Tjele Energinet.dk IPC 250 250164.1.1 [39] NO Kristiansand Statnett SF DK Tjele Energinet.dk IPC 350 350165.1.1 [40] SE Lindome Svenska Kraftnät DK Vester Hassing Energinet.dk IPC 282 370166.1.1 [41] SE Lindome Svenska Kraftnät DK Vester Hassing Energinet.dk IPC 285 360

167.1.1 SE Söderåsen Svenska Kraftnät DK Gørløsegård Energinet.dk IPC 400 830168.1.1 SE Borrby E.ON Elnät Sverige AB DK Bornholm Energinet.dk IPC 60 51169.1.1 SE Söderåsen Svenska Kraftnät DK Hovegård Energinet.dk IPC 400 830170.1.1 SE Mörarp 1and 2 E.ON Elnät Sverige AB DK Teglstrupgård Energinet.dk IPC 130 311171.1.1 AT Bisamberg APG CZ Sokolnice CEPS 220 250171.2.1 AT Bisamberg APG CZ Sokolnice CEPS 220 250172.1.1 AT Dürnrohr APG CZ Slavetice CEPS 380 1559172.1.2 AT Dürnrohr APG CZ Slavetice CEPS 380 1559181.1.1 AT Obersielach APG SI Podlog ELES 220 320182.1.1 AT Kainachtal APG SI Maribor ELES 380 1164182.2 .1 AT Kainachtal APG SI Maribor ELES 380 1164191.1.1 DE Niederstedem Amprion LU Vianden SEO 220 490 460 [42]191.1.2 DE Niederstedem Amprion LU Vianden SEO 220 490 230191.2.1 DE Bauler Amprion LU Vianden SEO 220 730 345 [43]191.2.2 DE Bauler Amprion LU Vianden SEO 220 730 230 [44]191.3.1 DE Bauler Amprion LU Flebour Creos Luxembourg 220 490

Present

15

Limited by the transformers or by the substationsof circuits of l ines

at Vol tageTransmission

capacityForecast

Connection between:Voltage of the circuit

Conventional trans-mission capacity of theconnection (thermal)*

Circuit ID From substation to substationPresentForecast

Vol tage

Page 114: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

114 ENTSO-E Statistical Yearbook 2011

Characteristics of the ENTSO-E tie lines as of 31 December 2011

Observations

[ 45 ] The 400kV link between GR-IT is composed of an overhead line and a submarine cable

[ 46 ] DC submarine cable

[ 47 ] Unit is M W instead of M VA

[ 48 ] DC submarine cable

[ 49 ] Unit is M W instead of M VA

[ 50 ] DC submarine cable

[ 51 ] DC Submarine Cable - 250M W instead 250 M VA

[ 52 ] Due to Exist ing Constraints the following applies to the 275kV double circuit t ie line (both 225.1.1 AND 225.2.1):IE Louth to NI Tandragee = 380M WNI Tandragee to IE Louth

[ 53 ] Due to Exist ing Constraints the following applies to the 275kV double circuit t ie line (both 225.1.1 AND 225.2.1):IE Louth to NI Tandragee = 380M WNI Tandragee to IE Louth

[ 54 ] In M ay 2007 out of operat ion 150 kV line Bitola1-Amyndeo; from June 2007 the new 400 kV line Bitola2-M elit i in operation

[ 55 ] Limited by the connected network

[ 56 ] Nominal voltage in Croat ia

[ 57 ] Limited by the connected network

[ 58 ] Nominal voltage in Croat ia

[ 59 ] Built for 750 kV

[ 60 ] 4500 M VA at 750 kV

[ 61 ] Limited by the Albanian network

[ 62 ] Capacity of current t ransformers at Bist rica

[ 63 ] Disconnected in Serbia

Page 115: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 115

*The conventional transmission capacity of cross-frontier tie-lines is based upon parameters standardised within former UCTE for the calculation of the thermal load capability of each line. For arial lines these are : ambient temperature of + 35°C, wind velocity of 0,56 m/s at a right angle to the line as well as the voltage value stated incolumn 10 or 11. The conditions relevant to system operation in various countries at various time of the year can strongly differ from those above. Because the real allowable load capability of the line depends on many other factors, such as load flow distribution, upholding of voltage, real ambient conditions, limits of stability, n-1 security,etc., the conventional transmission capacity has no relevance from the point of view of system operation or economics but allows just a comparison of order of magnitude of the various lines. Adding together the conventional transmission capacity of several tie-lines does not allow to infer on the real total transmission capability andleads to irrelevant results from the point of view of system operation.

( F ro nt ier po int .Line.C ircuit ) C ount ry N ame Operat ed b y C o unt ry N ame Op erat ed by

N r. kV kV M V A M V A M V A kV M V A kV

4131211101987654321

19 1.4 .1 094 022 gruobmexuL soerC tsooR ULnoirpmA reluaB ED

19 2 .1.1 094 022 gruobmexuL soerC frodsieH ULnoirpmA reirT ED

19 2 .2 .1 094 022 gruobmexuL soerC frodsieH ULnoirpmA tniuQ ED

2 0 1.1.1 aviD ISanreT ailgupideR TI 0021 9161 083 SELE a

2 0 1.2 .1 aviD ISanreT onaicirdaP TI 023 022 SELE a

2 0 5.1.1 [ 4 5] 005083AS OTPIsohthcarA RGanreTanitalaG TI

2 11.1.1 902 022 RIVAM röyG UHGPA tsO-düS neiW TA

2 11.1.2 902 022 RIVAM röyG UHGPA ldeisueN TA

2 12 .1.1 4151 083 RIVAM röyG UHGPAfrodsaraS TA

2 13 .1.1 4151 083 RIVAMylehtabmozS UHGPA tsO-düS neiW TA

2 2 1.1.1 ]74[ 0001 ]64[ 072 dirG lanoitaN egdnilleS BGETR sniradnaM RF

2 2 1.2 .1 ]94[ 0001 ]84[ 072 dirG lanoitaN egdnilleS BGETR sniradnaM RF

2 2 2 .1.1 052]05[ 052 dirG lanoitaNhsorcnehcuA BGdtL INOSeromnanorcyllaBIN

2 2 2 .2 .1 ]15[ 052052 dirG lanoitaNhsorcnehcuA BGdtL INOSeromnanorcyllaBIN

2 2 5.1.1 ]25[ 066572dirGriEhtuoLEIdtL INOSeegardnaTIN

2 2 5.2 .1 ]35[ 066572dirGriEhtuoLEIdtL INOSeegardnaTIN

2 3 1.1.1 09 231 NER osodniL TPEER sahcnoC saL SE

2 3 2 .1.1 473 022 NERohnicoP TPEER alivádaedlA SE

2 3 2 .2 .1 473 022 NERohnicoP TPEER alivádaedlA SE

2 3 2 .2 .1 9641004 NERaçaogaL TPEER alivádaedlA SE

2 3 2 .3 .1 643 022 NER ohnicoP TPEER ellecuaS SE

2 3 3 .1.1 0031 083 NER arieugalaF TPEER ollideC SE

2 3 4 .1.1 0331083 NER osodniL otlA TPEER elletraC SE

2 3 4 .1.2 0331 083 NER osodniL otlA TPEER elletraC SE

2 3 5.1.1 0821004 NERaveuqlATPEERselavorB SE

2 4 1.1.1 0031 004 AS OTPI ikinolassehT RGOSPEM ovorbuD KM

2 4 2 .1.1 [ 54 ] AS OTPIitileM RGOSPEM alotiB KM 400 1300

2 51.1.1 ]65[ 011]55[ 0597 021 SPO-PEH cenajledeN RHRIVAMitneL UH

2 51.2 .1 ]85[ 011]75[ 05411 011 SPO-PEH cajlohiM ijnoD RHRIVAM solkiS UH

2 51.3 .1 6421004 SPO-PEHcenivajreZ RHRIVAMzivéHUH

2 51.3 .2 6421004 SPO-PEHcenivajreZ RHRIVAMzivéHUH

2 52 .1.1 6421004 SPO-PEHovonitsenrE RHRIVAMscéPUH

2 52 .1.2 6421004 SPO-PEHovonitsenrE RHRIVAMscéPUH

2 6 1.1.1 7011 5311 004 acirtcelesnarT reiF ed elitroP OR SME1 padrejDSR

2 6 2 .1.1 75 56 011 acirtcelesnarTailobmiJ OR SME adnikiKSR

2 6 3 .1.1 09 011 acirtcelesnarT eraM uvortsO OR SME2 padrejDSR

2 6 4 .1.1 V aruG OR SME piSSR 91 78 011 acirtcelesnarT ii

2 71.1.1 9031 083 SME šiNSROSE dapaZ ajifoS GB

2 72 .1.1 79 011 SME 1 alrV EHSROSE kinzerB GB

2 73 .1.1 ejaZSROSE aluK GB 09 011 SME ra

2 75.1.1 ]06[ 8612]95[ 004057OSE anraVGBacirtcelesnarTaeccasIOR

2 77.1.1 RO ân 00010031004OSEiudolzoKGBacirtcelesnarTiner

ân 00010031004OSEiudolzoKGBacirtcelesnarTiner2 77.1.2 RO

2 78 .1.1 0385311004OSE ajdurboDGBacirtcelesnarTnamhaROR

2 8 0 .1.1 083 DA SEGC2 acirogdoPEMTSO2anariT LA 1264

2 8 1.1.1 672 022 DA SEGC2 acirogdoPEM HSEK sëjeD i uaV LA

2 8 2 .1.1 072 022 SME nerzirPSR HSEK azreiF LA

2 9 1.1.1 ]16[ 0520031 004 AS OTPI aidraK RG HSEK nassablE LA

2 9 2 .1.1 ]26[ 04021 051 AS OTPI sotruoM RG HSEK acirtsiB LA

2 9 3 .1.1 0002004AS OTPIatnaS aeN RGSAIETikseabaBRT

3 0 1.1.1 0070031 004 AS OTPI ikinolassehT RGOSE dargveogalB GB

3 2 1.1.1 6831 083 ED TenneT thcirneztE EDSPECdapaZ cedarH ZC

3 2 1.1.2 9651 083 ED TenneT thcirneztE EDSPEC ecitserP ZC

3 2 2 .1.1 6831083 ztreH05 frodsrhöR EDSPEC dohcyV cedarH ZC

3 2 2 .1.2 6831083 ztreH05 frodsrhöR EDSPEC dohcyV cedarH ZC

3 3 1.1.1 05015921 004 SME 3 acitobuSSRRIVAM avlafrodnáS UH

3 3 2 .1.1 26]36[ 97011 SME acitobuSSRRIVAMdegezS UH

3 4 1.1.1 321 011 OSPEMaknalaP avirK KMOSEacivakakS GB

3 4 1.2 .1 321 011 OSPEM acišuS KM OSEcirteP GB

3 4 2 .1.1 9031004OSPEMpitS KM OSEaligoM anevreC GB

3 51.1.1 aviD ISSPO- PEH anileM RH 4611 083 SELE a

3 51.2 .1 aviD ISSPO- PEH nilheP RH 023 022 SELE a

3 51.3 .1 67 011 SELE repoK ISSPO- PEH ejuB RH

3 51.4 .1 35 011 SELE acirtsiB aksrilI ISSPO- PEH ijlutaM RH

3 52 .1.1 4611 083 SELE okšrKISSPO- PEH irbmuT RH

3 52 .1.2 4611 083 SELE okšrKISSPO- PEH irbmuT RH

3 52 .2 .1 792 022 SELE ecvokriCISSPO- PEHcenivajreZ RH

3 52 .3 .1 101 011 SELE nimroFISSPO- PEH cenajledeN RH

3 6 1.1.1 6131 004 SPO-PEH oksjnoK RHHiB SON ratsoMAB

3 6 1.2 .1 ukaZ RHHiB SON ratsoMAB 113 022 SPO-PEH ca

3 6 1.3 .1 09 011 SPO-PEH ninK RHHiB SON ovoharGAB

15

V o lt ag eT ransmission

capacit yV o lt age

F orecast Present Fo recast Presentat

C o nnect ion bet ween:V o lt age o f t he circuit

C o nvent ional t rans-missio n cap acit y o f t heconnect io n ( t hermal) *

noitatsbus otnoitatsbus morFDI tiucriC

Limit ed by t he t ransf ormers or by t he subst at ions

senil fostiucric fo

Page 116: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

116 ENTSO-E Statistical Yearbook 2011

Characteristics of the ENTSO-E tie lines as of 31 December 2011

Observations

[ 64 ] Line is destroyed, currently under construction[ 65 ] Line is destroyed, currently under construction[ 66 ] DC submarine cable[ 67 ] Monopol[ 68 ] Limited by the measuring transformer of current[ 69 ] Value for 30°C (no data for 35°C)[ 70 ] Value for 30°C (no data for 35°C)[ 71 ] Value for 30°C (no data for 35°C)[ 72 ] Limitation due to current transformer in Kudowa SS[ 73 ] Value for 30°C (no data for 35°C)[ 74 ] Limitation due to current part of combined current/voltage transformer in Pogwizdów SS[ 75 ] Value for 30°C (no data for 35°C)[ 76 ] Limitation due to current part of combined current/voltage transformer in Pogwizdów SS[ 77 ] Value for 30°C (no data for 35°C)[ 78 ] Limitation due to current transformer in Mnisztwo SS[ 79 ] Value for 30°C (no data for 35°C)[ 80 ] On Polish side 400 kV line (internal designation between 50Hertz and PSE Operator)[ 81 ] On Polish side 400 kV line (internal designation between 50Hertz and PSE Operator)[ 82 ] Value for 30°C (no data for 35°C)[ 83 ] Submarine cable[ 84 ] Submarine cable[ 85 ] Limited by current transformer at Krosno[ 86 ] Limited by current transformer at Krosno[ 87 ] Temporary out of operation[ 88 ] Limeted by HF attenuator at UA side[ 89 ] Radial operation[ 90 ] Temporary out of operation[ 91 ] Value for 30°C (no data for 35°C)[ 92 ] DC Submarine cable[ 93 ] Temporary out of operation[ 94 ] Value for 30°C (no data for 35°C)[ 95 ] Temporary out of operation[ 96 ] Value for 30°C (no data for 35°C)

Page 117: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 117

*The conventional transmission capacity of tie lines is based upon parameters standardised within former UCTE for the calculation of the thermal load capability of each line. For arial lines these are : ambient temperature of + 35°C, wind velocity of 0,56 m/s at a right angle to the line as well as the voltage value stated in column 10 or11. The conditions relevant to system operation in various countries at various time of the year can strongly differ from those above. Because the real allowable load capability of the line depends on many other factors, such as load flow distribution, upholding of voltage, real ambient conditions, limits of stability, n-1 security, etc., theconventional transmission capacity has no relevance from the point of view of system operation or economics but allows just a comparison of order of magnitude of the various lines. Adding together the conventional transmission capacity of several tie lines does not allow to infer on the real total transmission capability and leads toirrelevant results from the point of view of system operation.

(Frontier point.Line.Circuit) Country Name Operated by Country Name Operated by

Nr. kV kV M V A M V A M V A kV M V A kV

1 2 3 4 5 6 7 8 9 10 11 12 13 14

361.4.1 BA Buško Blato NOS BiH HR Kraljevac HEP-OPS 110 115361.5.1 BA Buško Blato NOS BiH HR Peruca HEP-OPS 110 90361.6.1 BA Grude NOS BiH HR Imotski HEP-OPS 110 72361.7.1 BA Kulen Vakuf NOS BiH HR Gracac HEP-OPS 110 120 101362.1.1 BA Prijedor NOS BiH HR Mraclin HEP-OPS 220 297362 .2 .1 BA Prijedor NOS BiH HR Meduric HEP-OPS 220 297363.1.1 BA Trebinje NOS BiH HR Dubrovnik HEP-OPS 220 460363 .2 .1 BA Trebinje NOS BiH HR Dubrovnik HEP-OPS 220 460363 .3 .1 BA Capljina NOS BiH HR Opuzen HEP-OPS 110 84363 .4 .1 BA Neum NOS BiH HR Opuzen HEP-OPS 110 84363.5 .1 BA Neum NOS BiH HR Ston HEP-OPS 110 76363 .6 .1 BA Trebinje NOS BiH HR Komolac HEP-OPS 110 84364.1.1 BA Ugljevik NOS BiH HR Ernestinovo HEP-OPS 400 1264364.2 .1 BA Gradacac NOS BiH HR Ðakovo HEP-OPS 220 229364 .3 .1 BA Tuzla NOS BiH HR Ðakovo HEP-OPS 220 229364.4 .1 BA Bosanski Brod NOS BiH HR Slavonski Brod 2 HEP-OPS 110 115364.5 .1 BA Orasje NOS BiH HR Zupanja HEP-OPS 110 76371.1.1 HR Ernestinovo HEP-OPS RS Sremska Mitrovica EMS 400 1264371.2.1 HR Nijemci HEP-OPS RS Šid EMS 110 76371.3.1 HR Beli Manastir HEP-OPS RS Apatin EMS 110 78381.1.1 BA Trebinje NOS BiH M E Podgorica 2 CGES AD 380 1264381.2.1 BA Trebinje NOS BiH M E Perucica CGES AD 220 276381.3.1 BA Trebinje NOS BiH M E Herceg Novi CGES AD 110 90381.4.1 BA Bileca NOS BiH M E Vilusi CGES AD 110 84382.1.1 BA Sarajevo 20 NOS BiH M E Piva CGES AD 220 366382 .2 .1 BA e NOS BiH M E Pljevlja 1 CGES AD 110 90383.1.1 BA Višegrad NOS BiH RS Pozega EMS 220 311383 .2 .1 BA Bijeljina NOS BiH RS Lešnica EMS 110 123383 .3 .1 BA Zvornik NOS BiH RS HE Zvornik EMS 110 123383 .4 .1 BA Višegrad NOS BiH RS Zamrsten EMS 110 90383.5 .1 BA Ugljevik NOS BiH RS Sremska Mitrovica EMS 380 1264384.1.1 M E Ribarevine CGES AD RS Pec 3 EMS 380 1264384 .2 .1 M E Pljevlja 2 CGES AD RS Bajina Basta EMS 220 350384 .3 .1 M E Pljevlja 2 CGES AD RS Pozega EMS 220 365384 .4 .1 M E Pljevlja 1 CGES AD RS Zamrsten EMS 110 70

391.1.1 [64] MK Skopje 1 MEPSO RS Kosovo A EMS 220 311391.2.1 [65] MK Skopje 1 MEPSO RS Kosovo A EMS 220 311

391.3.1 MK Skopje 5 MEPSO RS Urosevac EMS 380 1218401.1.1 [66,67] DE Herrenwyk TenneT DE SE Kruseberg Baltic Cable AB 400 600

404.1.1 CZ Nosovice CEPS SK Varin SEPS 400 1205410.1.1 CZ Liskovec CEPS SK Pov. Bystrica SEPS 220 221420.1.1 CZ Sokolnice CEPS SK Senica SEPS 220 213424.1.1 CZ Sokolnice CEPS SK Krizovany SEPS 400 1205430.1.1 CZ Sokolnice CEPS SK Stupava SEPS 400 1363440.1.1 SK V.Kapusany SEPS UA-W Mukachevo NPC Ukrenergo 400 1115 831 [68]443.1.1 CZ Albrechtice CEPS PL Dobrzen PSE Operator S.A. 400 1088444.1.1 CZ Nošovice CEPS PL Wielopole PSE Operator S.A. 400 1088450.1.1 CZ Liskovec CEPS PL Kopanina PSE Operator S.A. 220 399460.1.1 CZ Liskovec CEPS PL Bujaków PSE Operator S.A. 220 399470.1.1 CZ Porící CEZ Distribuce PL Boguszów Tauron Dystrybucja S.A. 110 78 [69]470.1.2 CZ Porící CEZ Distribuce PL Boguszów Tauron Dystrybucja S.A. 110 78 [70]471.1.1 CZ Náchod CEZ Distribuce PL Kudowa Tauron Dystrybucja S.A. 110 123 [71] 57 [72]472.1.1 CZ Darkov CEZ Distribuce PL Pogwizdów Tauron Dystrybucja S.A. 110 123 [73] 114 [74]472.1.2 CZ Darkov CEZ Distribuce PL Pogwizdów Tauron Dystrybucja S.A. 110 123 [75] 114 [76]473.1.1 CZ Trinec CEZ Distribuce PL Mnisztwo Tauron Dystrybucja S.A. 110 123 [77] 114 [78]474.1.1 CZ Trinec CEZ Distribuce PL Mnisztwo/Ustro n Tauron Dystrybucja S.A. 110 123 [79]501.1.1 DE Vierraden 50Hertz PL Krajnik PSE Operator S.A. 220 402501.1.2 DE Vierraden 50Hertz PL Krajnik PSE Operator S.A. 220 402502.1.1 DE Hagenwerder 50Hertz PL Mikulowa PSE Operator S.A. 380 [80] 1302502.1.2 DE Hagenwerder 50Hertz PL Mikulowa PSE Operator S.A. 380 [81] 1302503.1.1 DE Neueibau ENSO Netz GmbH PL Turów Tauron Dystrybucja S.A. 110 39 [82]

601.1.1 [83] ES Puerto de la Cruz REE MA Melloussa 1 ONE 380 715601.1 .2 [84] ES Puerto de la Cruz REE MA Melloussa 2 ONE 380 715

700.1.1 PL Krosno Iskrzynia PSE Operator S.A. SK Lemešany SEPS 400 1252 831 [85]700.1.2 PL Krosno Iskrzynia PSE Operator S.A. SK Lemešany SEPS 400 1252 831 [86]

701.1.1 [87] PL Rzeszów PSE Operator S.A. UA Khmelnytska NPP NPC Ukrenergo 750 2676 2595 [88]702.1.1 [89] PL Zamosc PSE Operator S.A. UA Dobrotvir NPC Ukrenergo 220 279703.1.1 [90] PL Bialystok PSE Operator S.A. BY Ros Grodnoenergo 220 158 [91]704.1.1 [92] PL Slupsk PSE Operator S.A. SE Stärnö Svenska Kraftnät 442 600705.1.1 [93] PL Wólka Dobrynska PGE Dystrybucja S.A. BY Brest RUB Brestenergo 110 123 [94]705.1.2 [95] PL Wólka Dobrynska PGE Dystrybucja S.A. BY Brest RUB Brestenergo 110 123 [96]

15

Transmissioncapacity Vol tage

Forecast Present Forecast Present

of lines

Circuit ID From substation to substationat Vol tage

Connection between:Voltage of the circuit

Conventional trans-mission capacity of theconnection (thermal)*

Limited by the transformers or by the substationsof circuits

Page 118: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

118 ENTSO-E Statistical Yearbook 2011

Characteristics of the ENTSO-E tie lines as of 31 December 2011

Observations

[ 97 ] Limited by the measuring transformer of current[ 98 ] Out of operation[ 99 ] Limited by HF attenuator at RO side[ 100 ] Passive island operation limit [ 101 ] Passive island operation limit [ 102 ] Passive island operation limit [ 103 ] Not in operation[ 104 ] DC submarine cable[ 105 ] Used only for import to Finland[ 106 ] Used only for import to Finland[ 107 ] Used only for import to Finland[ 108 ] Used only for import to Finland[ 109 ] Used only for import to Finland[ 110 ] DC submarine cable[ 111 ] Limited by the relay protection circuits[ 112 ] Limited by the relay protection circuits[ 113 ] Limited by the current transformers[ 114 ] limited by the relay protection circuits[ 115 ] Limited by the relay protection circuits[ 116 ] Limited by the relay protection circuits[ 117 ] Limited by the current transformers[ 118 ] Limited by the relay protection circuits

Page 119: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 119

*The conventional transmission capacity of tie lines is based upon parameters standardised within former UCTE for the calculation of the thermal load capability of each line. For arial lines these are : ambient temperature of + 35°C, wind velocity of 0,56 m/s at a right angle to the line as well as the voltage value stated in column 10 or11. The conditions relevant to system operation in various countries at various time of the year can strongly differ from those above. Because the real allowable load capability of the line depends on many other factors, such as load flow distribution, upholding of voltage, real ambient conditions, limits of stability, n-1 security, etc., theconventional transmission capacity has no relevance from the point of view of system operation or economics but allows just a comparison of order of magnitude of the various lines. Adding together the conventional transmission capacity of several tie lines does not allow to infer on the real total transmission capability and leads toirrelevant results from the point of view of system operation.

(Frontier point.Line.Circuit) Country Name Operated by Country Name Operated by

Nr. kV kV M V A M V A M V A kV M V A kV

1 2 3 4 5 6 7 8 9 10 11 12 13 14

710.1.1 HU Györ MAVIR SK Gabcikovo SEPS 400 1330711.1.1 HU Göd MAVIR SK Levice SEPS 400 1330

720.1.1 HU Albertirsa MAVIR UA-W Zahidno Ukrainska NPC Ukrenergo 750 4010 1400721.1.1 HU Sajószöged MAVIR UA-W Mukachevo NPC Ukrenergo 400 1390 693 [97]722.1.1 HU Kisvárda MAVIR UA-W Mukachevo NPC Ukrenergo 220 209 305722.1.2 HU Tiszalök MAVIR UA-W Mukachevo NPC Ukrenergo 220 209 305730.1.1 HU Sándorfalva MAVIR RO Arad Transelectrica 400 1135 1109 1107731.1.1 HU Békéscsaba MAVIR RO Nadab Transelectrica 400 1300 1385740.1.1 RO Rosiori Transelectrica UA-W Mukachevo NPC Ukrenergo 400 1135 1107

741.1.1 [98] RO Isaccea Transelectrica UA PivdennoUkrainska AES NPC Ukrenergo 750 4064 2100 2595 [99]750.1.1 RO Stânca Transelectrica M D Costesti Moldenergo 110 119 90 [100]751.1.1 RO Husi Transelectrica M D Cioara Moldenergo 110 87 65 [101]752.1.1 RO Tutora Transelectrica M D Ungheni Moldenergo 110 87 76 [102]753.1.1 RO Issaccea Transelectrica M D Vulcanesti Moldenergo 400 1135 830

760.1.1 [103] 3 Maritsa3 ESO TR Babaeski TEIAS 400 1309761.1.1 BG Maritsa3 ESO TR Hamitabat TEIAS 400 1962770.1.1 NO Sildvik Statnett SF SE Tornehamm VE Eldistribution AB 130 70771.1.1 NO Ofoten Statnett SF SE Ritsem Svenska Kraftnät 400 880772.1.1 NO Røssåga Statnett SF SE Ajaure Svenska Kraftnät 220 250773.1.1 NO Nea Statnett SF SE Järpströmmen Svenska Kraftnät 400 500774.1.1 NO Lutufallet Statnett SF SE Höljes Fortum Distribution 130775.1.1 NO Eidskog Statnett SF SE Charlottenberg Fortum Distribution 130776.1.1 NO Hasle Statnett SF SE Borgvik Svenska Kraftnät 400 1510777.1.1 NO Halden Statnett SF SE Skogssäter Svenska Kraftnät 400 2000780.1.1 NO Varangerbotn Statnett SF FI Ivalo Fingrid 220 100790.1.1 NO Kirkenes Statnett SF RU Boris Gleb JSC FGC UES 154800.1 .1 FI Ossauskoski Fingrid SE Kalix Svenska Kraftnät 220801.1.1 FI Petäjäskoski Fingrid SE Letsi Svenska Kraftnät 400802.1 .1 FI Keminmaa Fingrid SE Svartbyn Svenska Kraftnät 400

803.1.1 [104] FI Raumo Fingrid SE Forsmark Svenska Kraftnät 400 550804.1 .1 FI Tingsbacka (Aland) Kraftnät Åland AB SE Senneby VE Eldistribution AB 110 80805.1.1 FI Raumo Fingrid SE Finnböle Svenska Kraftnät 500 800

810.1.1 [105] FI Yllikkälä Fingrid RU Viborg JSC FGC UES 400810.1.2 [106] FI Yllikkälä Fingrid RU Viborg JSC FGC UES 400811.1.1 [107] FI Kymi Fingrid RU Viborg JSC FGC UES 400812.1.1 [108] FI Nellimö Inergia Oy RU Kaitakoski JSC FGC UES 110 60813.1.1 [109] FI Imatra Fortum Corporation RU GES 10 JSC FGC UES 110 100820.1.1 [110] FI Espoo Fingrid EE Harku Elering AS 150 350

830.1 .1 LV TEC-1 Augstsprieguma tïkls EE Sindi Elering AS 330 1228831.1.1 LV TEC-2 Augstsprieguma tïkls EE Sindi Elering AS 330 1228832.1 .1 LV Valmiera Augstsprieguma tïkls EE Tsirguliina Elering AS 330 350833.1 .1 LV Valmiera Augstsprieguma tïkls EE Tartu Elering AS 330 350840.1 .1 RU Leningradskaja JSC FGC UES EE Balti Elering AS 330 590841.1.1 RU Kingisepp JSC FGC UES EE Eesti Elering AS 330 393842.1 .1 RU Pskov JSC FGC UES EE Taru Elering AS 330 389845.1.1 RU Velikoreckaya JSC FGC UES LV Rezekne Augstsprieguma tïkls 330 350850.1.1 LT Šiauliai/Telšiai LITGRID AB LV Jelgava (Viskali) Augstsprieguma tïkls 330 714 572 [111]851.1.1 LT Paneve s LITGRID AB LV Aizkraukle Augstsprieguma tïkls 330 714 686 [112]852.1.1 LT Klaipeda LITGRID AB LV Grobina Augstsprieguma tïkls 330 714 572 [113]853.1.1 LT IAE LITGRID AB LV Liksna Augstsprieguma tïkls 330 830854.1.1 LT Paroveja LITGRID AB LV Nereta Augstsprieguma tïkls 110 75855.1.1 LT Zarasai LITGRID AB LV Daugavpils Augstsprieguma tïkls 110 86856.1.1 LT IAE LITGRID AB LV Daugavpils Augstsprieguma tïkls 110 102860.1 .1 LT IAE LITGRID AB BY Polock Belenergo 330 966 857 [114]861.1.1 LT IAE LITGRID AB BY Smorgon Belenergo 330 830862.1 .1 LT IAE LITGRID AB BY Minskaja TEC-5 Belenergo 330 1786 857 [115]863.1 .1 LT Vilnius LITGRID AB BY Molodechno Belenergo 330 714864.1 .1 LT Alytus LITGRID AB BY Grodno Belenergo 330 714865.1.1 LT IAE LITGRID AB BY Opsa Belenergo 110 63866.1 .1 LT IAE LITGRID AB BY Vidzi Belenergo 110 63867.1.1 LT s LITGRID AB BY Kaziani Belenergo 110 44 29 [116]868.1 .1 LT Pabrad e LITGRID AB BY Podolci Belenergo 110 44869.1 .1 LT Kalveliai LITGRID AB BY Asmena Belenergo 110 63 38 [117]870.1.1 LT Šalcininkai LITGRID AB BY Voronovo Belenergo 110 86 46 [118]871.1.1 LT Leipalingis LITGRID AB BY Grodno Belenergo 110 75880.1 .1 LT Bitenai LITGRID AB RU Sovetsk UES-SO-CDA 330 714881.1.1 LT Bitenai LITGRID AB RU Sovetsk UES-SO-CDA 330 714882.1 .1 LT Kruonio HAE LITGRID AB RU Sovetsk UES-SO-CDA 330 714883.1 .1 LT Kybartai LITGRID AB RU Nesterovo UES-SO-CDA 110 75884.1 .1 LT Pagegiai LITGRID AB RU Sovetsk UES-SO-CDA 110 75885.1.1 LT Pagegiai LITGRID AB RU Sovetsk UES-SO-CDA 110 75

Circuit ID From substation to substation

Connection between:

15

Voltage of the circuitConventional trans-

mission capacity of theconnection (thermal)*

Forecast Present Forecast PresentVol tage

Limited by the transformers or by the substationsof lines

at Vol tage

of circuits

Transmissioncapacity

Page 120: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

120 ENTSO-E Statistical Yearbook 2011

Abbreviations used of TSO operators

AT Austria APG Austria Power Grid AGVUEN Vorarlberger Übertragungsnetz GmbH

(until January 2012 VKW-Netz GmbH)

BA Bosnia - Herzegovina NOS BiH Nezavisni operator sustava u Bosni i Hercegovini

BE Belgium Elia Elia System Operator SA

BG Bulgaria ESO Electroenergien Sistemen Operator EAD

CH Switzerland swissgrid swissgrid ag

CZ Czech Republic CEPS CEPS a.s.

DE Germany Amprion Amprion GmbHTransnetBW TransnetBW

(until February 2012 EnBW Transportnetze AG)TenneT DE TenneT TSO GmbH50Hertz 50Hertz Transmission GmbH

DK Denmark Energinet.dk IPC Energinet.dk Independent Public Enterprice

EE Estonia Elering AS Elering AS

ES Spain REE Red Eléctrica de España S.A.

FI Finland Fingrid Fingrid Oyj

FR France RTE Réseau de Transport d'Electricité

GB United Kingdom National Grid National Grid Electricity Transmission plcSONI Ltd System Operator for Northern Ireland Ltd

(The connections operated by SONI Ltd are described with the country code NI .)

SHETL Scottish Hydro Electric Transmission LimitedSP Transmission Scottish Power Transmission plc

GR Greece IPTO SA Independent Power Transmission Operator S.A.(until January 2012 Hellenic Transmission System Operator S.A.)

HR Croatia HEP-OPS HEP-Operator prijenosnog sustava d.o.o.

HU Hungary MAVIR MAVIR Magyar Villamosenergia-ipari Átviteli Rends-Átviteli Rendszerirányító zerirányító ZártköruenMuködo Részvénytársaság

IE Ireland EirGrid EirGrid plc

IT Italy Terna Terna - Rete Elettrica Nazionale SpA

LT Lithuania LITGRID AB LITGRID AB

LU Luxembourg Creos Luxembourg Creos Luxembourg S.A.

LV Latvia Augstsprieguma tïkls AS Augstsprieguma tïkls

ME Montenegro CGES AD Crnogorski elektroprenosni sistem AD

MK FYROM MEPSO Macedonian Transmission System Operator AD

NL The Netherlands TenneT NL TenneT TSO B.V.

NO Norway Statnett Statnett SF

PL Poland PSE Operator PSE Operator S.A.

PT Portugal REN Rede Eléctrica Nacional, S.A.

RO Romania Transelectrica C.N. Transelectrica S.A.

RS Serbia EMS JP Elekt Srbije

SE Sweden Svenska Kraftnät Affärsverket Svenska Kraftnät

SI Slovenia ELES Elektro Slovenija d.o.o.

SK Slovak Republic SEPS Slovenska elektrizacna prenosova sustava, a.s.

AL Albania KESH Albanian Electroenergetic Corporation

BY Belarus Belenergo Belenergo

MA Morocco ONE Office National de l'Electricité

MD Republic of Moldavia Moldenergo Moldenergo

RU Russia JSC FGC UES Federal Grid Company

TR Republic of Turkey TEIAS Türkiye Elektrik Iletim A.S.

UA Ukraine NPC Ukrenergo NPC Ukrenergo

UA-W Ukraine West NPC Ukrenergo NPC Ukrenergo

Page 121: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

Reasons: R1 - Maintenance, R2 - Repair, R3 - New construction, R4 - Overload (also calculated), R5 - False operation, R6 - Failure in protection device or other element,R7 - Outside impacts (animals, trees, fire, avalance,...), R8 - Very exceptional conditions (weather, natural disaster,...), R9 - Other reasons, R10 - Unknown reasons

ENTSO-E Statistical Yearbook 2011 121

Unavailability of international tie lines - yearly overview 2011

Thermal conventional transmission capacity

[ M V A ]

11.1.1 DE - Diele ( TenneT DE ) NL - Meeden ( TenneT NL ) 380 1382 R10 6493 649311.1.2 DE - Diele ( TenneT DE ) NL - Meeden ( TenneT NL ) 380 1382 R1 1266 126613.1.1 DE - Siersdorf ( Amprion ) NL - Maasbracht ( TenneT NL ) 380 1645 R1 606 60613.1.2 DE - Rommerskirchen ( Amprion ) NL - Maasbracht ( TenneT NL ) 380 1698 R9 5193 607 640 394625.1.1 BE - Van Eyck ( Elia ) NL - Maasbracht ( TenneT NL ) 380 1207 R1 19 1925.1.2 BE - Van Eyck ( Elia ) NL - Maasbracht ( TenneT NL ) 380 1270 R1,R2 6928 6369 457 10226.1.1 BE - Zandvliet ( Elia ) NL - Geertruidenberg ( TenneT NL ) 380 1476 R1,R2 20560 205602 6 . 2 . 1 BE - Zandvliet ( Elia ) NL - Borssele ( TenneT NL ) 380 1476 R1,R2 20738 2073827.1.1 NL - Eemshaven ( TenneT NL ) NO - Feda ( Statnett SF ) 450 700 R2,R6 60855 17655 4320028.1.1 GB - Isle of Grain ( National Grid ) NL - Maasvlakte ( TenneT NL ) 450 500 R6 13500 1350041.1.1 BE - Aubange ( Elia ) LU - Belval ( SOTEL ) 220 358 R1,R2 22486 3889 1859741.1.2 BE - Aubange ( Elia ) LU - Belval ( SOTEL ) 220 358 R1 16363 16003 36041.2.1 BE - Aubange ( Elia ) LU - Belval ( SOTEL ) 150 157 R1 1548 154851.1.1 BE - Monceau ( Elia ) FR - Chooz ( RTE ) 220 338 R1 10924 6183 474151.2.1 BE - Avelgem ( Elia ) FR - Mastaing ( RTE ) 380 1168 R1 6616 7 6314 39 25651.2.2 BE - Avelgem ( Elia ) FR - Avelin ( RTE ) 380 1303 R1,R7 14972 11 14893 6851.3.1 BE - Achene ( Elia ) FR - Lonny ( RTE ) 380 1168 R1 5813 8 5114 645 4652.1.1 BE - Aubange ( Elia ) FR - Moulaine ( RTE ) 220 395 R1 1414 540 644 12 21852 .2 .1 BE - Aubange ( Elia ) FR - Mont St Martin ( RTE ) 220 395 R1 6318 631871.1.1 DE - Ensdorf ( Amprion ) FR - Vigy ( RTE ) 380 1790 R1 12405 1240571.1.2 DE - Ensdorf ( Amprion ) FR - Vigy ( RTE ) 380 1790 R1 14100 2151 1194971.2.1 DE - Ensdorf ( Amprion ) FR - St-Avold ( RTE ) 220 261 R1,R2,R9 108093 550 559 35603 44640 7018 16282 344172.1.1 DE - Eichstetten ( TransnetBW ) FR - Vogelgrün ( RTE ) 220 338 R2 514 51472.1.2 DE - Eichstetten ( TransnetBW ) FR - Muhlbach ( RTE ) 380 1684 R1 16608 16113 49581.1.1 CH - Bassecourt ( swissgrid ) FR - Sierentz ( RTE ) 380 1172 R1,R9 18076 2517 14043 807 15 69481.2.1 CH - Laufenburg ( swissgrid ) FR - Sierentz ( RTE ) 380 1330 R1,R9 6013 4 271 3561 217781.3.1 CH - Bassecourt ( swissgrid ) FR - Mambelin ( RTE ) 380 1330 R1,R9 46732 7431 35284 358 1114 254582.1.1 CH - Verbois ( swissgrid ) FR - Bois-Tollot ( RTE ) 380 1552 R1 6403 14 638982.1.2 CH - Chamoson ( swissgrid ) FR - Bois-Tollot ( RTE ) 380 1552 R1,R9 60301 25409 29789 3320 1775 88 2 . 2 . 1 CH - Verbois ( swissgrid ) FR - Génissiat ( RTE ) 220 237 R1 11 1182 .2 .2 CH - Verbois ( swissgrid ) FR - Génissiat ( RTE ) 220 237 R1 5 582 .5 .1 CH - Riddes ( swissgrid ) FR - Cornier ( RTE ) 220 216 R1 8302 1365 6442 4958 2 . 6 . 1 CH - St.-Triphon ( swissgrid ) FR - Cornier ( RTE ) 220 222 R1,R8 11261 3 6489 476983.1.1 DE - Asphard ( swissgrid/EnBW Tr.Netze Strom ) FR - Sierentz ( RTE ) 380 1168 R1 6085 4812 127391.1.1 FR - Albertville ( RTE ) IT - Rondissone ( Terna ) 380 1244 R1 6274 627491.1.2 FR - Albertville ( RTE ) IT - Rondissone ( Terna ) 380 1244 R1 6125 612592.1.1 FR - Trinite Victor ( RTE ) IT - Camporosso ( Terna ) 220 319 R1 28838 6774 19859 220593.1.1 FR - Villarodin ( RTE ) IT - Venaus ( Terna ) 380 1237 R1 19672 16062 3610

102.2 .1 CH - Laufenburg ( swissgrid ) DE - Kühmoos ( TransnetBW ) 220 410 R1,R9 15794 749 13988 1057102.3 .1 CH - Laufenburg ( swissgrid ) DE - Kühmoos ( TransnetBW ) 220 430 R1,R9 17916 2110 768 13985 1053102.3.2 CH - Laufenburg ( swissgrid ) DE - Kühmoos ( TransnetBW ) 380 1527 R1,R9 6624 3457 2149 573 445102.4 .1 CH - Laufenburg ( swissgrid ) DE - Kühmoos ( TransnetBW ) 380 1527 R1 2750 62 570 2118102.4.2 CH - Laufenburg ( swissgrid ) DE - Kühmoos ( Amprion ) 380 1607 R1,R3,R9 65811 142 3226 12971 32347 14007 1065 2053102.5.1 CH - Laufenburg ( swissgrid ) DE - Tiengen ( Amprion ) 380 1122 R1 2209 161 2048103.1.2 CH - Beznau ( swissgrid ) DE - Tiengen ( Amprion ) 220 335 R1 322 322104.1.1 CH - Asphard ( swissgrid ) DE - Kühmoos ( TransnetBW ) 380 1263 R1,R2 6379 6357 22105.1.1 CH - Laufenburg ( swissgrid ) DE - Trossingen ( TransnetBW ) 380 1386 R1,R9 2458 274 2184107.1.1 CH - Laufenburg 220 kV ( swissgrid ) DE - Laufenburg 110 kV ( ED ) 110 200 R1 2559 35 514 2010111.2.1 AT - Bürs ( VIW ) DE - Herbertingen ( Amprion ) 220 389 R1,R2,R9 13510 101 1100 659 4467 560 1679 183 3616 557 588111.3.1 AT - Bürs ( VIW ) DE - Dellmensingen ( Amprion ) 220 492 R1,R9 7870 6314 1172 88 296115.5.1 AT - St. Peter ( APG ) DE - Altheim ( TenneT DE ) 220 301 R1,R2 3369 1387 1232 380 370115.6.1 AT - St. Peter ( APG ) DE - Simbach ( TenneT DE ) 220 301 R1 1779 404 1062 313115.9.1 AT - St. Peter ( APG ) DE - Pirach ( TenneT DE ) 220 518 R1 28882 5594 5645 6246 3222 6198 1007 970115.10.1 AT - St. Peter ( APG ) DE - Pleinting ( TenneT DE ) 220 449 R1 7249 1420 494 4910 229 196116.1.1 AT - Westtirol ( APG ) DE - Leupolz ( Amprion ) 380 1316 R1 356 356116.2.1 AT - Westtirol ( APG ) DE - Memmingen ( Amprion ) 220 762 R1,R2 6987 6143 431 413117.1.1 AT - Silz ( APG ) DE - Oberbrunn ( TenneT DE ) 220 793 R1,R9 831 146 329 356117.1.2 AT - Silz ( APG ) DE - Oberbrunn ( TenneT DE ) 220 793 R1 1118 349 255 514121.2.1 CH - Gorduno ( swissgrid ) IT - Mese ( Terna ) 220 278 R1 6281 6281121.3.1 CH - Soazza ( swissgrid ) IT - Bulciago ( Terna ) 380 1224 R1 -6 -6121.4.1 CH - Lavorgo ( swissgrid ) IT - Musignano ( Terna ) 380 1204 R1 23251 3822 19429123.1.1 CH - Riddes ( swissgrid ) IT - Avise ( Terna ) 220 309 R1,R9 11271 266 4593 6412123.2 .1 CH - Riddes ( swissgrid ) IT - Valpelline ( Terna ) 220 309 R1,R9 10282 3858 6424123.3 .1 CH - Serra ( swissgrid ) IT - Pallanzeno ( Terna ) 220 278 R1 6378 6378124.1.1 CH - Robbia ( swissgrid ) IT - Gorlago ( Terna ) 380 1330 R1,R2,R9 19808 3155 16328 325

December[min]

August[min]

September[min]

October[min]

November[min]

Apr i l[min]

M a y [min]

June [min]

July [min]Circuit ID From substation To substat ion

Vol tage[ k V ] Major Reason

January[min]

February[min]

March[min]

Time whole year [min]

Page 122: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 123: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

Reasons: R1 - Maintenance, R2 - Repair, R3 - New construction, R4 - Overload (also calculated), R5 - False operation, R6 - Failure in protection device or other element,R7 - Outside impacts (animals, trees, fire, avalance,...), R8 - Very exceptional conditions (weather, natural disaster,...), R9 - Other reasons, R10 - Unknown reasons

ENTSO-E Statistical Yearbook 2011 123

Unavailability of international tie lines - yearly overview 2011

Thermal conventional transmission capacity

[ M V A ]

124.1.2 CH - Robbia ( swissgrid ) IT - San Fiorano ( Terna ) 380 1330 R1,R2,R8 18853 2154 371 16328141.1.1 AT - Meiningen ( Vorarlberg Netz ) CH - Y-Meiningen ( swissgrid ) 220 494 R1 38189 27406 10783141.2.1 AT - Meiningen ( Vorarlberg Netz ) CH - Winkeln ( swissgrid ) 220 765 R1,R9 41039 171 30863 2063 6084 1858142.1.1 AT - Westtirol ( APG ) CH - Pradella ( swissgrid ) 380 1330 R1,R2,R9 12226 9443 2001 782142.2 .1 AT - Westtirol ( APG ) CH - Pradella ( swissgrid ) 380 1330 R1 3433 3433151.1.1 ES - Hernani ( REE ) FR - Argia ( RTE ) 380 1137 R1 19279 19279151.2.1 ES - Irún ( REE ) FR - Errondenia ( RTE ) 132 0 R1,R2 6304 6304151.3.1 ES - Arkale ( REE ) FR - Argia ( RTE ) 220 339 R1 4871 4871151.4.1 ES - Biescas ( REE ) FR - Pragnères ( RTE ) 220 183 R1,R6 445 368 77152.1.1 ES - Benós ( REE ) FR - Lac d'Oo ( RTE ) 110 0 R9 583 583153.1.1 ES - Vich ( REE ) FR - Baixas ( RTE ) 380 1348 R2,R9 43566 10977 31170 523 896161.1.1 DE - Flensburg ( TenneT DE ) DK - Ensted ( Energinet.dk IPC ) 220 332 R1,R9,R10 34746 232 5113 29401161.2.1 DE - Flensburg ( TenneT DE ) DK - Kassø ( Energinet.dk IPC ) 220 332 R9,R10 16159 5191 10968161.3.1 DE - Audorf ( TenneT DE ) DK - Kassø ( Energinet.dk IPC ) 380 1078 R1,R2,R3 42475 228 21550 20697161.3.2 DE - Audorf ( TenneT DE ) DK - Kassø ( Energinet.dk IPC ) 380 1078 R9,R10 20690 531 16803 3356171.1.1 AT - Bisamberg ( APG ) CZ - Sokolnice ( CEPS ) 220 250 R1,R9 9641 5930 3711171.2.1 AT - Bisamberg ( APG ) CZ - Sokolnice ( CEPS ) 220 250 R1,R9 9931 477 5871 3458 125172.1.1 AT - Dürnrohr ( APG ) CZ - Slavetice ( CEPS ) 380 1559 R1 419 419172.1.2 AT - Dürnrohr ( APG ) CZ - Slavetice ( CEPS ) 380 1559 R1,R9 1141 611 530181.1.1 AT - Obersielach ( APG ) SI - Podlog ( ELES ) 220 320 R10 7 7191.3.1 DE - Bauler ( Amprion ) LU - Flebour ( Creos Luxembourg ) 220 490 R1 632 632192.1.1 DE - Trier ( Amprion ) LU - Heisdorf ( Creos Luxembourg ) 220 490 R1,R9 600 516 84192.2 .1 DE - Quint ( Amprion ) LU - Heisdorf ( Creos Luxembourg ) 220 490 R1 1644 1644201.1.1 IT - Redipuglia ( Terna ) SI - Divaca ( ELES ) 380 1619 R6,R8 87 81 6201.2 .1 IT - Padriciano ( Terna ) SI - Divaca ( ELES ) 220 320 R6 127 127205.1.1 IT - Galatina ( Terna ) GR - Arachthos ( IPTO SA ) 380 500 R1,R6,R9,R10 100798 601 5024 6718 15630 12421 17060 20602 22692 50221.1.1 GB - Sellindge ( National Grid ) FR - Mandarins ( RTE ) 270 1000 R1,R2,R3 329049 9203 30180 43200 44637 43197 44640 44640 43200 21255 3872 1025221.2 .1 GB - Sellindge ( National Grid ) FR - Mandarins ( RTE ) 270 1000 R1,R3,R6 61314 30580 4863 671 55 913 578 888 3798 16974 1086 908222.1 .1 GB - Auchencrosh ( National Grid ) NI - Ballycronanmore ( SONI Ltd ) 250 250 R1,R2,R10 231979 50 43140 44640 43200 15330 42479 43140222 .2 .1 GB - Auchencrosh ( National Grid ) NI - Ballycronanmore ( SONI Ltd ) 250 250 R2,R10 141713 62 10611 44700 43200 43140225.1.1 IE - Louth ( EirGrid ) NI - Tandragee ( SONI Ltd ) 275 660 R4 124 124231.1.1 ES - Las Conchas ( REE ) PT - Lindoso ( REN ) 132 90 R3 14459 14459232 .2 .1 ES - Aldeadávila ( REE ) PT - Lagoaça ( REN ) 400 1469 R1 296 296232 .3 .1 ES - Saucelle ( REE ) PT - Pocinho ( REN ) 220 346 R1 59661 246 3006 22291 34118233.1 .1 ES - Cedillo ( REE ) PT - Falagueira ( REN ) 380 1300 R1,R9 2917 2605 293 19234.1 .1 ES - Cartelle ( REE ) PT - Alto Lindoso ( REN ) 380 1330 R1,R2 4397 283 4114234.1.2 ES - Cartelle ( REE ) PT - Alto Lindoso ( REN ) 380 1330 R1 4491 4491235.1.1 ES - Brovales ( REE ) PT - Alqueva ( REN ) 400 1280 R1 3314 3314241.1.1 MK - Dubrovo ( MEPSO ) GR - Thessaloniki ( IPTO SA ) 400 1300 R1,R6 8665 374 949 6962 380242.1 .1 MK - Bitola ( MEPSO ) GR - Meliti ( IPTO SA ) 400 1300 R1,R2 3206 1123 331 1752261.1.1 RS - Djerdap 1 ( EMS ) RO - Portile de Fier ( Transelectrica ) 400 1135 R1,R2 2568 403 2165271.1.1 BG - Sofija Zapad ( ESO ) RS - Nis ( EMS ) 380 1309 R1,R2,R10 3041 55 40 33 2913275.1.1 RO - Isaccea ( Transelectrica ) BG - Varna ( ESO ) 400 2168 R1 1164 987 177277.1.1 RO - Tântareni ( Transelectrica ) BG - Kozlodui ( ESO ) 400 1300 R1 6958 2381 4024 553277.1.2 RO - Tântareni ( Transelectrica ) BG - Kozlodui ( ESO ) 400 1300 R1 7676 2381 3739 304 1252278.1.1 RO - Rahman ( Transelectrica ) BG - Dobrudja ( ESO ) 400 1135 R1 107365 324 33358 11087 38 16325 17028 28676 529282.1 .1 AL - Fierza ( KESH ) RS - Prizren ( EMS ) 0 270 R1,R9 5257 4768 489291.1.1 AL - Elbassan ( KESH ) GR - Kardia ( IPTO SA ) 0 1300 R1 7664 7664292.1 .1 AL - Bistrica ( KESH ) GR - Mourtos ( IPTO SA ) 0 120 R2 360 360293.1 .1 GR - Nea Santa ( IPTO SA ) TR - Babaeski ( TEIAS ) 400 2000 R1,R2,R4,R6,R10 8042 414 3645 244 620 67 2985 11 56301.1.1 BG - Blagoevgrad ( ESO ) GR - Thessaloniki ( IPTO SA ) 400 1300 R1,R6,R10 6379 5815 20 535 9321.1.1 CZ - Hradec Zapad ( CEPS ) DE - Etzenricht ( TenneT DE ) 400 1386 R1 6420 6420321.1.2 CZ - Prestice ( CEPS ) DE - Etzenricht ( TenneT DE ) 400 1491 R1 5496 2322 2238 625 311322.1 .1 CZ - Hradec Vychod ( CEPS ) DE - Röhrsdorf ( 50Hertz ) 400 1386 R1,R9 7445 589 6856322.1.2 CZ - Hradec Vychod ( CEPS ) DE - Röhrsdorf ( 50Hertz ) 400 1386 R2,R9 4292 1011 1400 1881331.1.1 HU - Sandorfalva ( MAVIR ) RS - Subotica ( EMS ) 400 1295 R1,R9 2276 2072 204351.1.1 HR - Melina ( HEP-OPS ) SI - Divaca ( ELES ) 400 1164 R6,R9 100 7 93351.2.1 HR - Pehlin ( HEP-OPS ) SI - Divaca ( ELES ) 220 320 R8 14 2 12352.1.2 HR - Tumbri ( HEP-OPS ) SI - Krško ( ELES ) 400 1164 R9 66 66371.1.1 HR - Ernestinovo ( HEP-OPS ) RS - Sremska Mitrovica ( EMS ) 400 1264 R1 2522 1562 960381.1.1 BA - Trebinje ( NOS BiH ) ME - Podgorica 2 ( CGES AD ) 380 1264 R8 24953 24953383.1 .1 BA - Visegrad ( NOS BiH ) RS - Vardiste ( EMS ) 220 311 R2,R3 4277 935 2593 592 157383.5 .1 BA - Sremska Mitrovica ( NOS BiH ) RS - Sremska Mitrovica ( EMS ) 380 1264 R1,R10 2376 2339 37384.1 .1 RS - Pec 3 ( EMS ) ME - Ribarevine ( CGES AD ) 400 1264 R1,R2,R10 1442 85 1121 17 219384 .2 .1 RS - Bajina Basta ( EMS ) ME - Pljevlja 2 ( CGES AD ) 220 350 R1,R3 9999 741 601 2832 5825

October[min]

November[min]

December[min]

June [min]

July [min]

August[min]

September[min]

February[min]

March[min]

Apr i l[min]

May [min]Major Reason

Time whole year [min]

January[min]Circuit ID From substation To substat ion

Vol tage[ k V ]

Page 124: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 125: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

Reasons: R1 - Maintenance, R2 - Repair, R3 - New construction, R4 - Overload (also calculated), R5 - False operation, R6 - Failure in protection device or other element,R7 - Outside impacts (animals, trees, fire, avalance,...), R8 - Very exceptional conditions (weather, natural disaster,...), R9 - Other reasons, R10 - Unknown reasons

ENTSO-E Statistical Yearbook 2011 125

Unavailability of international tie lines - yearly overview 2011

Thermal convent ional t ransmission capacit y

[ M V A ]

3 8 4 .3 .1 17061R563022) DA SEGC ( 2 ajlvejlP - EM) SME ( agezoP - SR 6071

3 9 1.1.1 0464400234007440023404644046440023404644002340854402304046440065259R113022) SME ( A ovosoK - SR) OSPEM ( 1 ejpokS - KM

3 9 1.2 .1 0464400234007440023404644002340023404644002340854402304046440614259R113022) SME ( A ovosoK - SR) OSPEM ( 1 ejpokS - KM

3 9 1.3 .1 20313R,2R8121083) SME ( cavesorU - SR) OSPEM ( 5 ejpokS - KM 178 1124

4 0 1.1.1 DE - Herrenwyk ( TenneT DE ) SE - Kruseberg ( Balt ic Cable AB ) 400 600 R1,R4,R6,R10 58052324309297177343

4 0 4 .1.1 15989R,1R5021004) SPES ( niraV - KS) SPEC ( ecivosoN - ZC 9722060708

4 10 .1.1 19R,2R,1R122022) SPES ( acirtsyB .voP - KS) SPEC ( cevoksiL - ZC 36139269820 3833

4 2 0 .1.1 13366374760112R,1R312022) SPES ( acineS - KS) SPEC ( ecinlokoS - ZC

4 2 4 .1.1 021311R5021004) SPES ( ynavozirK - KS) SPEC ( ecinlokoS - ZC 99931219

4 3 0 .1.1 26565R,1R3631004) SPES ( avaputS - KS) SPEC ( ecinlokoS - ZC 923356

4 4 0 .1.1 UA-W - M ukachevo ( NPC Ukrenergo ) SK - V.Kapusany ( SEPS ) 400 4287455462040716318719R,6R,2R,1R5111

4 4 3 .1.1 ezrboD - LP) SPEC ( ecithcerblA - ZC 66202134064751129R,2R,1R8801004) .A.S rotarepO ESP (

4 4 4 .1.1 896716R,1R8801004) .A.S rotarepO ESP ( elopoleiW - LP) SPEC ( ecivosoN - ZC 20 17678

4 50 .1.1 828420151R993022) .A.S rotarepO ESP ( aninapoK - LP) SPEC ( cevoksiL - ZC 274

4 6 0 .1.1 7032848179445460159R,1R993022) .A.S rotarepO ESP ( wókajuB - LP) SPEC ( cevoksiL - ZC

50 1.1.1 607213250118346641550245163289R,8R,2R,1R204022) .A.S rotarepO ESP ( kinjarK - LP) ztreH05 ( nedarreiV - ED

50 1.1.2 068983524081527130848R,2R,1R204022) .A.S rotarepO ESP ( kinjarK - LP) ztreH05 ( nedarreiV - ED

50 2 .1.1 640264021R2031083) .A.S rotarepO ESP ( awoukiM - LP) ztreH05 ( redrewnegaH - ED

50 2 .1.2 854185411R2031083) .A.S rotarepO ESP ( awoukiM - LP) ztreH05 ( redrewnegaH - ED

6 0 1.1.1 083) ENO ( 1 assuolleM - AM) EER ( zurC al ed otreuP - SE 0 9779002346713225579408676R,2R,1R

70 0 .1.1 62183291805222322401446R,2R,1R2521004) SPES ( ynašemeL - KS) .A.S rotarepO ESP ( ainyzrksI onsorK - LP

70 0 .1.2 1894229333055542R,1R2521004) SPES ( ynašemeL - KS) .A.S rotarepO ESP ( ainyzrksI onsorK - LP 0533639

70 4 .1.1 084906622R,1R006054) täntfarK aksnevS ( önrätS - ES) .A.S rotarepO ESP ( kspuS - LP 26129

710 .1.1 751022R,1R0331004) SPES ( ovokicbaG - KS) RIVAM ( reoyG - UH 19405 83 482 187

711.1.1 1723011856566078R,7R,2R0331004) SPES ( eciveL - KS) RIVAM ( döG - UH 34

72 0 .1.1 HU - Albert irsa ( M AVIR ) UA-W - Zahidno Ukrainska ( NPC Ukrenergo ) 750 4010 R1,R6 81232 231 12020 1 98915570155011052432390

72 1.1.1 809511R0931004) ogrenerkU CPN ( ovehcakuM - W-AU) RIVAM ( degözsójaS - UH 7771 65811826

72 2 .1.1 389321R902022) ogrenerkU CPN ( ovehcakuM - W-AU) RIVAM ( adrávsiK - UH 2715925712821

72 2 .1.2 272311R902022) ogrenerkU CPN ( ovehcakuM - W-AU) RIVAM ( kölazsiT - UH 7436885733673 0 .1.1 70510160160792329R,1R5311004) acirtcelesnarT ( darA - OR) RIVAM ( avlafrodnaS - UH73 1.1.1 7166857881R0031004) acirtcelesnarT ( badaN - OR) RIVAM ( abascsékéB - UH 799274 0 .1.1 6613189126567295935130811R5311004) ogrenerkU CPN ( ovehcakuM - W-AU) acirtcelesnarT ( iroisoR - OR8 0 0 .1.1 022) täntfarK aksnevS ( xilaK - ES) jyO dirgniF ( iksoksuassO - IF 0 R9 12 128 0 3 .1.1 04624321003109789322773132311447461301R,6R,3R,1R055004) täntfarK aksnevS ( kramsroF - ES) jyO dirgniF ( omuaR - IF8 0 5.1.1 04622R,1R008005) täntfarK aksnevS ( elöbnniF - ES) jyO dirgniF ( omuaR - IF 26408 10 .1.1 004) SEU CGF CSJ ( grobiV - UR) jyO dirgniF ( äläkkillY - IF 0 R1 32640 30060 25808 10 .1.2 004) SEU CGF CSJ ( grobiV - UR) jyO dirgniF ( äläkkillY - IF 0 R6 78 788 11.1.1 004) SEU CGF CSJ ( grobiV - UR) jyO dirgniF ( imyK - IF 0 R1 32640 30060 25808 13 .1.1 011) SEU CGF CSJ ( 01 SEG - UR) jyO mutroF ( artamI - IF 0 R8 403 4038 2 0 .1.1 051) SA gnirelE ( ukraH - EE) jyO dirgniF ( oopsE - IF 0 503080110540310626760169023657101R,9R,6R,1R8 50 .1.1 0705937011R417033) slkït amugeirpstsguA SA ( )ilaksiV( avagleJ - VL) BA DIRGTIL ( iaišleT/iailuaiŠ - TL 4915 7548 51.1.1 LT - Panev 8671345220320181625943R,2R417033) slkït amugeirpstsguA SA ( elkuarkziA - VL) BA DIRGTIL ( sy8 52 .1.1 LT - Klaip 73741557222R,1R417033) slkït amugeirpstsguA SA ( aniborG - VL) BA DIRGTIL ( ad 80188 53 .1.1 9633318018401032512R,1R038033) slkït amugeirpstsguA SA ( anskiL - VL) BA DIRGTIL ( EAI - TL8 54 .1.1 LT - Parov 766651268590431R57011) slkït amugeirpstsguA SA ( atereN - VL) BA DIRGTIL ( aj8 55.1.1 7012129137R,1R68011) slkït amugeirpstsguA SA ( slipvaguaD - VL) BA DIRGTIL ( iasaraZ - TL8 56 .1.1 483555797569R,1R201011) slkït amugeirpstsguA SA ( slipvaguaD - VL) BA DIRGTIL ( EAI - TL 4408 6 0 .1.1 65029933424656495494982621R669033) ogreneleB ( kcoloP - YB) BA DIRGTIL ( EAI - TL8 6 1.1.1 7474259081618462884242321R038033) ogreneleB ( nogromS - YB) BA DIRGTIL ( EAI - TL8 6 2 .1.1 1730529R,3R,1R6871033) ogreneleB ( 5-CET ajaksniM - YB) BA DIRGTIL ( EAI - TL 791604113046440464400234046440359248368 6 3 .1.1 19R,1R417033) ogreneleB ( onhcedoloM - YB) BA DIRGTIL ( suinliV - TL 2981 10010432544359168 6 4 .1.1 86911801282213351R417033) ogreneleB ( ondorG - YB) BA DIRGTIL ( sutylA - TL8 6 5.1.1 436013R,1R36011) ogreneleB ( aspO - YB) BA DIRGTIL ( EAI - TL 6060 45748 6 6 .1.1 1423047142445789817733140713R,2R36011) ogreneleB ( izdiV - YB) BA DIRGTIL ( EAI - TL8 6 7.1.1 LT - Did 7631222785357161R44011) ogreneleB ( inaizaK - YB) BA DIRGTIL ( silasai8 6 8 .1.1 LT - Pabrad 34023545204644631273R44011) ogreneleB ( iclodoP - YB) BA DIRGTIL ( 8 6 9 .1.1 12R36011) ogreneleB ( anemsA - YB) BA DIRGTIL ( iailevlaK - TL 6645 092512173468 70 .1.1 LT - Šal 1R68011) ogreneleB ( ovonoroV - YB) BA DIRGTIL ( iaknini 33080 4766214955648 71.1.1 21482R,1R57011) ogreneleB ( ondorG - YB) BA DIRGTIL ( signilapieL - TL 4902258166448 8 0 .1.1 LT - Bit 51511589725815861073147R,3R,1R417033) ADC-OS-SEU ( kstevoS - UR) BA DIRGTIL ( ian8 8 1.1.1 LT - Bit 1681029230464459081615793R,1R417033) ADC-OS-SEU ( kstevoS - UR) BA DIRGTIL ( ian8 8 2 .1.1 773419R,1R417033) ADC-OS-SEU ( kstevoS - UR) BA DIRGTIL ( EAH oinourK - TL 8285 60928 8 3 .1.1 88548111758236589R,1R57011) ADC-OS-SEU ( ovoretseN - UR) BA DIRGTIL ( iatrabyK - TL8 8 4 .1.1 LT - Pag 54061R57011) ADC-OS-SEU ( kstevoS - UR) BA DIRGTIL ( iaig 60458 8 5.1.1 LT - Pag 20842R57011) ADC-OS-SEU ( kstevoS - UR) BA DIRGTIL ( iaig 4583 88131

noitatsbus oTnoitatsbus morFDI tiucriCD ecember

[ min]A pr il [ min]

M ay [ min]

June [ min]

July [ min]

A ugust [ min]

Sept ember [ min]

Oct ober [ min]

N ovember [ min]

V o l t age [ kV ]

M ajor R easonT ime whole year [ min]

January [ min]

February [ min]

M arch [ min]

Page 126: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 127: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

European Network ofTransmission System Operators

for Electricity

1 ENTSO-E Net generation, exchanges

and consumption 2011

2 Yearly values / operation and

physical exchanges

3 System information

4 Glossary of statistical terms

Page 128: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 129: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 129

The Glossary of statistical terms contains all terms used in this Statistical Yearbook. The corresponding explanationsare available on the ENTSO-E internet site www.entsoe.eu under "Resources / Data Portal / Statistical Glossary".

Term Definition

Alternating Current An electric current that reverses its direction at regularly intervals.( AC )

Circuit Length The circuit length of an electrical line or cable is the actual length of each of its conductorsor the mean of the lengths of the conductors, if there is any appreciable difference in theirlengths.

Classification of According to the category of Primary Energy and fuel used for electricity generation, thePower Units ENTSO-E statistics considers the following classification in its publications:

• Hydro• Nuclear• Fossil fuels• Other Renewable (…of which wind, solar)• Not clearly identifiable

Consumption See Load and relations to consumption in the following document:https:www.entsoe.eu/fileadmin/user_upload/_library/publications/ce/Load_and_Consumption _Data.pdf

Consumption The electrical energy absorbed by the motor pumps in raising the water into the upper re-of Pumps servoir for the generation of electrical energy. It should include the electrical energy consu-

med by the auxiliary equipment and transformer losses during pumping.See also Pumped Storage.

Control Area It is a coherent part of the ENTSO-E interconnected system (usually coinciding with theterritory of a company, a country or a geographical area, physically demarcated by the positionof points for measurement of the interchanged power and energy to the remaininginterconnected network), operated by a single TSO, with physical loads and controllablegeneration units connected within the Control Area. A Control Area may be a coherent part ofa control block that has its own subordinate control in the hierarchy of secondary control (seealso the Glossary in the Operation Handbook).

Conventional A theoretical value based on parameters standardized within ENTSO-E (Continental Europe)Transmission for calculation of the thermal load capacity of each tie line. These are:ambient temperatureCapacity of + 35ºC, wind velocity of 0,56 m/s at a right angle to the line, as well as the voltage of the line.

Cross Frontier Line See Tie Line.

Glossary of statistical terms

Page 130: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

130 ENTSO-E Statistical Yearbook 2011

Term Definition

Direct Current ( DC ) Direct current or DC electricity is the continuous movement of electrons from an area ofnegative (-) charges to an area of positive (+) charges through a conducting material.

Electricity Balance Computes the consumption of electricity from the supply side (not metered in final consumer).( Electricity Supply In the ENTSO-E, it is presented as the sum of Net Production (split by Classification of Po- Situation ) wer Units) minus the Consumption of Pumps plus Exchange Balance. Due to fact that con-

sumption is computed from the supply side, the electricity balance includes the distributionand Transmission Losses.

Energy Not Supplied An estimation of the energy not supplied to final customers due to incidents in the transmis-( ENS ) sion network.

Equivalent Time of The duration of an interruption in minutes multiplied by the energy not supplied divided by theInterruption consumption for the last 12 months. This value allows a direct comparison of interruptions that

occurred during a year.

Exchange Balance The difference between the inside and outside physical flows on each interconnection line ofa country.

Hydro Electricity derived from the potential and kinetic energy content of water. It can be classifiedas: Storage Hydro, Run of River, Pure Pumped Storage and Mixed Pumped Storage.

Load Load on a power system is referred to as the hourly average active power absorbed by allinstallations connected to the transmission network or to the distribution network. The load isthe value at a given moment of the electrical power supplied or absorbed at any point of asystem as determined by an instantaneous measurement or by the integration of powerduring a given period of time. Load can refer to a consumer, an appliance, a group of consumersor appliances or a network. Load is the power consumed by the network including (+) thenetwork losses but excluding (-) the consumption for pumped storage and excluding (-) theconsumption of generating auxiliaries.For the power balance, the load of each country, also called reference load, is represented at11 a.m. on the 3rd Wednesday of each month without regard to the export power.Concerning the calculation method for the 24 load values, the countries use the averagevalues of the 10, 15 or 60 minutes load preceding the hour.

Net Generating Net Generating Capacity (NGC) of a power station is the maximum electrical net active powerCapacity it can produce continuously throughout a long period of operation in normal conditions, where:

• "net" means the difference between, on the one hand, the gross generating capacityof the alternator(s) and, on the other hand, the auxiliary equipmentsʼ load and thelosses in the main transformers of the power station;

• for thermal plants “normal conditions” means average external conditions (weather,climate…) and full availability of fuels;

• for hydro and wind units, “normal conditions” refer to the usual maximum availabilityof primary energies, i.e. optimum water or wind conditions.

Net Generating Capacity of a country is the sum of the individual Net Generating Capacityof all power stations connected to either the transmission grid or to the distribution grid.

Glossary of statistical terms

Page 131: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

ENTSO-E Statistical Yearbook 2011 131

Term Definition

Net Generation It is the Gross Generation less the electrical energy absorbed by Generating Auxiliaries and( Net Production ) the losses in the main generator transformers.

Network Reliability Reliability is a general term encompassing all the measures of the ability of the system,generally given as numerical indices, to deliver electricity to all points of utilization withinacceptable standards and in the amounts desired. Network reliability (comprising genera-tion and transmission facilities) can be described by two basic and functional attributes:Adequacy and Security.

Not Clearly Identifiable Not Clearly Identifiable Sources comprise Power Plants or Power Units, which, according toSources Sources the primary energy used, cannot be categorized.

Nuclear Electricity generated by the use of thermal energy released from the fission of nuclear fuelin a reactor.

Other Renewable In the ENTSO-E statistics, this category comprises all Renewable Energy Sources exceptEnergy Sources total Hydro production.

Peak Load The maximum hourly demand during a period of time: day, month or year. (Maximum Load)

Physical Energy Flow It represents the real movements of energy between neighboring countries metered in cross-border Tie Lines in both directions, in the system and out of the system.

Physical Inside Flows See Physical Energy Flow.

Physical Outside Flows See Physical Energy Flow.

Power Produced in It is the sum of the net electrical power produced in power stations participating in synchronousParallel Operation operation. It takes into account the spinning reserve, but excludes units injecting into systems,

which are coupled to the interconnected network only by an AC / DC-link, and those, whichcannot be operated with 50 Hz.Remark: Since January 2007, these data are no longer collected and published.

Protection Device Equipment applied to electric power systems to detect abnormal and intolerable conditionsand to initiate corrective actions to ensure continuity of electric service, to limit injury to peopleand to limit damage to equipment. These devices include lightning arresters, surge protectors,fuses and relays with associated circuit breakers, reclosers and so forth.

Reference Points The dates and times for which power data are collected. Reference points are characteristicenough of the entire period studied to limit the data to be collected to the data at the referencepoints.

Glossary of statistical terms

Page 132: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

132 ENTSO-E Statistical Yearbook 2011

Term Definition

Renewable Energy It means renewable non-fossil energy sources (wind, solar, geothermal, wave, tidal, hydropower,Sources biomass, landfill gas, sewage treatment plant gas and biogases).( Renewables )

Representativity This is a specific ENTSO-E term, which generally means that certain values might not cover( National Represen- the whole country. It is expressed as a percentage. There might be differences between thetativity Index ) approaches of the ENTSO-E statistics and System Adequacy reports.

Scheduled ( Program, The program Outside Flows (respectively Inside Flows) of electricity in one member stateDeclared )Inside Flows on the basis of an underlying contractual arrangement to the effect that the simultaneous

corresponding take-up (program Inside Flows (respectively Outside Flows)) of electricity willtake place in another Member State or a third country.

Substation Facility equipment that steps up or steps down the voltage in utility power lines. Voltage isstepped up where power is sent through long distance transmission lines, and stepped downwhere the power is to enter local distribution lines. They can be classified as normal outsidesubstation, armoured substation and underground substation.

Thermal Conventional Electricity generated by an electric power plant using mainly coal, petroleum (derivates) or( Fossil Fuels) gas as its primary source of energy. In ENTSO-E statistics, we use the term “Fossil fuels”

for the production of electricity with a thermal process that is not generated using Nuclear orRenewable Energy Sources.

Tie Line A transmission line connecting two countries.

Transit An energy flow that occurs in a country, which is neither the source nor the sink of the energyflow. The energy flow arrives in the grid over one border and leaves the country over one or moreborders

Transmission Losses The difference between the fed-in (generation) and the delivery energy to distributors. Own-needs for the operation of the grid are included.

Transmission System A company that is responsible for operating, maintaining and developing the transmissionOperator ( TSO ) system for a control area and its interconnections.

Vertical Load The total amount of power flows out of the transmission network into distribution and largecustomer networks.

Glossary of statistical terms

Page 133: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 134: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

Publisher: Secretariat of ENTSO-EAvenue de Cortenbergh 100, B-1000 Brussels

Internet: www.entsoe.eu

Executive Editor: Secretariat of ENTSO-E

Managing Editor: Edda Asmus

Production Editor: Vattenfall Europe Information Services

Printed by: Oswald

Photo: Energinet.dk

und Martin WerbeagenturBerlin

May not be reproduced without prior permission of ENTSO-E

Page 135: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012
Page 136: Statistical Yearbook 2011...ENTSO-E Statistical Yearbook 2011 5 Country Company Abbreviation AT Austrian Power Grid AG APG Vorarlberger Übertragungsnetz GmbH VUEN (until January 2012

European Network ofTransmission System Operatorsfor Electricity

Contact

ENTSO-E AISBL

Avenue de Cortenbergh 100

1000 Brussels

Belgium

Tel + 32 2 741 09 50

Fax + 32 2 741 09 51

info @ entsoe.eu

www.entsoe.eu